Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-3437 (SFD)
�:� P.O. BOX 1504. 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: L 05_00003437 -/ 81328. VICTORIA LN . 764-270-999-114 -300234- DWELLING —SINGLE FAMILY MEDIUM HIGH DENSITY -RES 213593 BUILDING & SAFETY DEPARTMENT UfC[�1e . _PER` M_ 1= O er: AUGA LA QUINTA U 1 O 200JEFF MCQUEEN DETACHED 5 00 N GAINEY CENTER 350 Cl of: S OTTSDALE, AZ 85258 FIpI,�N DEU/NT� PT. Architect or Engineer: rJ -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect., CIB / License ontractor: �N(3 7ADate: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any city or.county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or ' that he or she is exempt therefromand the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If; however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State .License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm underpenalty of perjury that there is a construction lending agency for the performance of the work'for which this permit is issued (Sec. 3097, Civ. C.). •. Lender's Name: Lender's Address: LQPERMIT SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 92253 ('760) 777-6005 Lic. No.: 672285 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/04/05 ------------------------------------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ' _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' -compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NTL UNION INS Policy Number 6436568 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to'the workers' compensation provisions of Section 3700 of the Labor Code, /lshall forthwith comply with those provisions. te: pplicant: i� 0✓ �_ WAR NVAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - SUBJECT ANEMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. _ . APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. - 1. Each person upon whose behalf. this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La-Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. -2. Anypermit'issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. ' I certify that 1 have read this application.and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and here thorize representatives of thiscou ty o enter upon the above-mentioned property for ' ection purpo . D�Ee: a Sigre (Appticant.or Agent): .!,Application Number . . . 05.-00003437 Permit . . . . .. BUILDING PERMIT • Additional desc . Permit. -Fee 1038.50 Plan Check Fee 168.76 Issue.Date Valuation . . . 213593 Expiration Date 1/31/06 ` Qty. Unit,Charge Per Extension, BASE FEE 639.50 114.00 3.5000 THOU -BLDG 100,001-500,.000 399.00 Permit ..MECHANICAL Additional desc_. - Permit Fee . . . . 83.50 Plan Check Fee 5.22 Issue Date Valuation 0 Expiration Date 1/31/06 Qty Unit Charge Per Extension BASE FEE .15:00 2.00 9,0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 4.00 6.5000.EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 113.47 Plan Check Fee 7.09 Issue Date Valuation. 0 Expiration Date 1/31/06' Qty Unit Charge Per Extension BASE FEE 15.00 2455.00 .0350 ELEC NEW RES -.1 OR 2 FAMILY 85.93 627.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL' . 12.54 Permit . . PLUMBING Additional desc Permit Fee 147.00 Plan Check Fee 9.19 Issue' Date Valuation 0 Expiration Date 1/31/06 Qty. Unit Charge Per Extension BASE FEE 15.00 13.006.0000 EA PLB FIXTURE 78.00 1.00•, 15.0000 EA PLB.BUILDING SEWER " 15.00 LQPERMTT Application Number • . 05-00003437 Permit. •, . PLUMBING Qty Unit, Charge Per .. Extension 1.00'.• 7.5000 EA PLB WATER,HEATER/VENT 7,.50 -.. 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00'` -.1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS-PIPE.>=5 4.50 1.00 15.0000 EA PLB GAS METER 15.00 Permit . . . GRADING,PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee.. .00 Issue Date Valuation . . . 0 Expiration "Date .. .1/31/06 Qty Unit Charge Per Extension BASE FEE 15.00 ------- Special Notes and Comments SFD - Lot 114; 245.5 SF Plan 5210C w/Casita . (266s -f), MBR,Box Bay (26sf), Ext Garage (109sf).-Permit does not.include block wall, pool or driveway approach. 75% REDUCTION TO PLAN CHECK FEES DUE TO. MULTIPLE -ISSUANCE OF SAME PLAN TYPE - •Other Fees . . . . . . . . . ART IN PUBLIC PLACES, -RES 33.98 DIF COMMUNITY CENTERS -RES 97.00 ,- DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 16.88 DIF FIRE PROTECTION -RES 97.00 GRADING.PLAN CHECK FEE .00 DIF `LIBRARIES - RES 225.00- DIF.PARK MAINT FAC - RES 5.00 DIF'PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 21..35,'., DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 • Fee summary - Charged Paid Credited Due Permit Fee Total 1397.47 .00 .00 1397.47 Plan Check Total 190.26 .00 .00 190.26 - Other Fee Total 2477.21 .00 .00 2477.21 Grand Total 4064.94 .'00 00 4064:94 . LQPERMIT /�s JCM Inspections' 39725 Garand Lane Suite F ah Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: [?] IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons rt n� Unresolved l s: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips _5:!d 00 psi to 33.04 kips/33,000 lbs F. None ❑ See Below Calibration Date: Machine# )191311 L4 ?-3I Phase g.., Lot# L) Product PlanSa n g —z'; \ N' G�tb f i lel VIAPL - Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. L-6 f Yes No 4 q43, ©– ❑ PPe'C11nsin11 AQ ❑ _ S� VQz 19- ❑ 5;A'Z, �- I y Eg- ❑ 51— ❑ Ct1r c z.1�/i5 n moi' .,v •S�� y.�-NAA.y 0! ❑ —E5— ❑ /' , �zk❑ 0� ❑ Gc e cSt �c� n 3 oL ©' ❑ 0ikA-_-Jr3 am L4 Cetr._Px ...i 4'"�- 0' ❑ • Et ❑ PY, nom; ^ 5 s�.�, Com" El 1 I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certification No. 0842216-89 Contractor's Representative: 1 Copy 1 JCM Inspections Copy 2 Project Superintendent ; Copy 3 Goveming Agency Page ' of _ t JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 7.60-345-5554 - Fax: 760-772-3895 IN S P E C T I o NS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA ❑✓ IBC ❑ Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DC CCC 'General Contractor: Architect. Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): 14 ; a � Supplier: Superior Time Sampled: 1 t , ©S rte. Mix Design: D83625P. Time in Mixer (min.): $ Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): Addmixture: POZZ 322N Concrete Temperature.(F): q LA Truck #: _ Ticket #: 1 Ambient Air Temperature (F): ) Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: ❑ None ❑ See Below Location of Sample: T o x' n r -. cck( o $r.. T i (4C-, W.�1 ❑ No Samples Taken. Description of Work Inspected: Phase Lot.# � Product Plan ``7 91 Ila -a- o� 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams. (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/S6-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD71,), Pad Footings and additional rebar placed as per these details and as noted on S -, R �i cin. Q.;00f;. �' WY r1�. pw C. A k�c' Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. off. --l. _ ba - 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx $� A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. / — C) z 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx ' Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise, noted, and to the best ofmy ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jac C. Millin ICC Certificati �n o: 0842216-80 Contractor's Representative: f� Je Copy 1 JCM Inspections Copy 2 Project Superintendent d. Copy 3 : Governing Agency �; Page of JAN Q4,2006 17:22 BCI*TESTING,ril 000-000-00000 ; s' Page 1_ CaICERTS Certified Rating Jtv. January, 4 2006 x - • ryr a } ' 81328 Victoria Lane This Compliance rating is for the home located at:, } . La Quinta CA, 92253 Certificate Number: CC3-1798354606 I, Date Inspected: January, 3 2006 CaICERTS Rater: William Henson t` _ CC2004076 HERS'Analyst: N/A . « Builder/ Developer: Shea Homes, Inc. •. B Project:, Trilogy @ La Quinta Phase: Phase 12B t' Plan Name:, 5210 „ I • Lot Number: 114 - Specifics about this home: T r General Information - . uilding Envelope , Conditioned Floor Area: 2000 Square Feet '• Conditioned Volume: >r 0 Cubic Feet a Front Orientation: N/A Surface Area Proposed Actual RU Value Factor R I Value U I Factor Number of ores. i • - t Nesting and Cooling Systems, Windows Heating Equipment: Fumace: 0.8 Cooling Equipment: AC: 12 - • HVAC Air Distribution Duct Location: Attic ' Duct Leakage Target: 6.0 . ' Duct Insulation R -Value:. 6 r Air Infiltration Blower Door Target, 120 • �X TESTED -PAGE''I OF 7.1 + Water Heating 5 stern Vro osed OAPPROVED AS PART OF SAMPLE GROUP 1. TY A Size I Fuel I EF I Distributio"n FIRM: BCI TESTING Water Heating S stem Actual ADDRES 77-760 COUNTRY CLUB DRIVE, SUITE I TY Size Fuel EF Distribution r PALM DESEERT, GA 92211 Testin Results y PHONE:760-772-2954 ' f ain S stem HVAC System., Pro osed Actual Orientation " AreaU Tested Duct Design Com liance: N/A. ested Duct in Conditioned Space: U ested Reduced Duct Surface Area: N/A SHGC Value SHGC Value - • HVAC Air Distribution Duct Location: Attic ' Duct Leakage Target: 6.0 . ' Duct Insulation R -Value:. 6 r Air Infiltration Blower Door Target, 120 • �X TESTED -PAGE''I OF 7.1 + Water Heating 5 stern Vro osed OAPPROVED AS PART OF SAMPLE GROUP 1. TY A Size I Fuel I EF I Distributio"n FIRM: BCI TESTING Water Heating S stem Actual ADDRES 77-760 COUNTRY CLUB DRIVE, SUITE I TY Size Fuel EF Distribution r PALM DESEERT, GA 92211 Testin Results y PHONE:760-772-2954 ' f ain S stem HVAC System., Tested Duct Leakage: Yes -Passed Tested TXV: Yes - Passed Tested Duct Design Com liance: N/A. ested Duct in Conditioned Space: N/A ested Reduced Duct Surface Area: N/A ested Infiltration Reduction Credit: N/A NG SIGNATOR /DATE .. F _ The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed havi been verified and approved by the CaICERTS Certified'Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom; CA 95763, , q4 f ,JAN ;a4, 2006 17:23 'BCI*.TESTING, ril 000-000-00000 Page 2 CaICERTS Certified Rating ' . 9 � ' January, 4 2006 This Compliance rating is for the home located at: LLa Qui Victoria Lane }_ � a Quints CA, 92253 Certificate Number: CC3-1798354615 I , Date Inspected:- 3anuarV, 3 2006 CaICERTS Rater: William Henson C ` CC2004076 HERS Analyst: N/A'' Builder/ Developer:,. Shea Homes, Inc, Projectt Trilogy @ La Quints Phase: Phase 128' Plan Name: Casita Lot Number: 114•--t .A Specifics about this home: Generallnformition Uilding Fnvelo e Conditioned Floor Area: 400 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Surface Nu ber • Area Pro osed, Actual R . Value U or R Value U I Factor - actor Number of Stories: i Heating and Cooling Systems Windows Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 ' Pro osed Actual Orientation Area ested Duct Design Compliance: U ested Duct in Conditioned Space: 'as U Tested Reduced Duct Surface Area: N/A SHGC Value SHGC Value HVAC Air Distribution Duct Location: Attic - Duct Leakage Target: 6.0 Duct Insulation R -Value:' 6 Air.Infiltration slower Door Target: 48 TESTED (PAv81 OF 1) . Water Heating E=m Pro osed =APPROVED AS, PART OF SAMPLE GROUP TY I Size. Fuel EF Distribution FIRM: BCI TESTING . Water Hedtin S stem Actual ADOMA MM COUNTRY CLUB DRIVE. >lurm I 4 TY Size Fuel EF Distribution I I I• ` r PALM dt>l11111111IIT. OA. $2311 Testin Results • PNOiV�:,7en-M-21 t si n System HVAC System temested Duct Leakage: Yes- Passed asTXV: Yes - Passed ested Duct Design Compliance: A• WA - ested Duct in Conditioned Space: 'as N/A Tested Reduced Duct Surface Area: N/A Tested infiltration Reduction Credit: • N/A ' • _ LTJ -J i, . .� v Cn Nd SIG TURF DATE The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion,Summary is provided only after the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. `` ♦' ` . ` ' I1 j JCM Inspections _._._ �.•a,.. 39725 Garand Lane Suite F ! fl __. l-- Palm Desert, CA 92211 Phone: 760-345-5554 - Fax: 760-772-3895 IN S P E C T i O tV S EPDXY INSPECTION REPORT Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 f roject Ad.iress: City: E]Title 24 AWS F/ UBC Other: _ern P,"enue 62 La Quinta, CA File # Q D 1.1 App#D1;.4... ..tient: Sub -Contractor: hr.a La Ouinta, LLC DOther (;-n •ral Contractor: Architect: v. Structural Engineer: :' hea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Anchor Bolts Rebar Weather: Epoxy Type:..�r .-, •i ^ w J�``, , ..-° , ; Unresolved Ite s: Epoxy Shelf Life: -� None Cleaning Method(s): Q ' r LAHole xA. See Below „sc iption of Work Inspected: LJ i \ rv' C —� t„ S i) a... �IC�Ona i:ane� K ^.'. rte;. I \ .• ,, ..- 't `,'. .',` '•j^ L�,,.�1. .. i .. -.--_---_ .` o!k con_ dies with written approval from Structural Engineer and ICBO Evaluation Report # - . " I : icr !,y cer.ily that I have inspected all of the above work, unless otherwise noted, and to the best of my ability Ihave found this work Lomply with the approved s. specifications applicable building laws. Final report issued at project completion. --tor:"Jack C. Millin 'ICC Certifica2216-49 Contractor's Representative: I JC: I Inspections Copy 2 Project Superintendent "r - Copy 3 Governing Agency Page _ of