Loading...
0402-356 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date Date `� /+ Signature of Contractor %k.1�%f F , OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business•& Professionals Code). . ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044,- Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date *1 " Signature of Owner ` WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the,following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (f) I have and will maintain workers' compensation insurance, as required by Section 3700 of`the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier vtiLD FEPUDL1C. MEN; Policy No. NITYC1(}$'F +30 . C (This. section need not be completed if the permit valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I/s al%,forthwith comply with thos pr �% ns.� Date: / Applicant-/—//,//// l' Warning: Failure to.secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees IMPORTANT. Application is hereby made to the Director of Building and Safety for a permit -subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request -and for whose benefit work is performed under or pursuant to any. permit• issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a.result of this application becomes null and void if . work is not commenced within 180 days from date of issuance of .such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information:is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter'upon the above-mentioned propertylor inspection purposes. Signature (Owner/Agent);. ,` Date , BUILDING PERMIT PERMIT# fid -35 DATE VALUATION LOT TRACT $12%042,M 26 2.93,234 JOB SITE APN " ADDRESS 7.9_770 V17P:Mfo 1) r4Vy, W9A MM4 OWNER CONTRACTOR / DESIGNER / ENGINEER 11,99AR 17.0MIS Cid' CATIF016M% LE.`�vvi AIR HOUR S 0r- CN.1F'a)1d:M ,. 78.401 C iRGH-WAY 1i' 78A 01 C 11101MAY 111 LA0 -T nt`, CA 9.225:4 1:.AQt.111:UA CA 02253 1600 177-0131 i• 0131 ML -ft 'Slj.', 4 USE OFPERMIT w 07.�•"1'~Ya.'1.�.b-) Y LINELUl. G ii7kl`17 .. LOT 20, i',l.AN 2Y. PERMIT OCIESNOT INC 1,fine BWCK "(VALi.% POO,, SPA Oft. DRIVEWAY. �,.4'i'?ZaAcii, Ys%kirm13'C"Fm To i'L6esm C13.wx € EE, DUE 7'6 it IRAIPLE ISSU.&NC E OF SAME PLAIT TYPE TRACT CONSTRUCTION 3TRUCTION %349.00 OF PORCHiPt .TIO 471.00 Sp , &AACIEJC,ARPORT ' 4 f 8.09 OF , EsTmui° i) r osu Car" Ci:►.t�bwrrzu ',["nm 136,342X0 y,�e CONSTRUCTION ,;E, 101.000-418—Q00 "59149 PLAM CHECK.. FILE 101.€ 00-439-31 S MECHANICAL FV_ 101-000-421-000 $47.00 ELS�.%,TRICA1, FEE 101-000420-000 S124.eo PLUMBING.F99 101.000-419.000 S115817 STfEONO MOTION FEE- MND 101-000-Y -000 $13.63 CRAD540 FEE HH -000-423-000 $15,00 '033 'I:b.C.11'`ZA 1:41f ACT FEL'' $7,4Ct5:O0 ` ON M"ft:+a"CTLONAND P:C W CHWK $3,690.53 RR-PAU) IMM APR 0 6 2004 ')TA], PX"WrD.UZ NOW CITY OF LA QUINTA FINANCE DEPT. RECEIPT DATEBY r/ (�- . r, : "X/ DAT FI ALE 1o INSP C OR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROV LS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts _ Slab Grade Retum Air / Steel Combustion Air _ Roof Deck A - Exhaust Fans O.K. to Wrap F.A.U. Framing / C pressor _ Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final G(. Final BLOCKWALL APPROVALS steel POOLS'. SPAS Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final _ Waste Lines Z Water Piping v Heater Final Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation _ Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring�— Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: V HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 of 2' CF -6R Site Address: ( 79�7.7.02Viento-Drive. J Permit Number: Tract Number: 29323 Plan #: 2Y Phase: 5 Lot Number: 26 Project: ' Esplanade Builder: Lennar Homes An installation certificate is required to be posted at the building site or made avalible for all appropriate inspections. After completion of final inspection, a copy must be provided to the Building Department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Equipment of Efficiency Duct Heating Heating Equip. CEC CertifiedName Identicle (AFUE, etc.) Location Duct Load Capacity Type and Model Name Systems (>= CFAR) (attic, etc.) R -value (BTU / Hr) (BTU / Hr) FC S Air Tf UJAVO-9• attic Cooling Equipment of Efficiency Duct Cooling Cooling Equip. CEC CertifiedName Identicle (SEER, etc.) Location Duct Load Capacity Type and Model Number Systems (>=CF -1R) (attic, etc.) R -value (BTU / Hr) (BTU / Hr) USAirHP attic 2 . J. I, the undersigned, verify that equiVnVnt ustea aoove is: 1) is me acivai equipment instanea, z) equroaitun to or FuUm -efficient than that specified in the rt icate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residentiI b di n ) quipment that meets or exceeds the appropriate requirements for manufactured devices (from the plice Gulations or Pa 6), where applicable. J Q°c Team Heating & Air Signature, ate Installing Subcontractor(Co. Name OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: System F7-1 of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow , x.06 ` u f Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) PT -24 Compliance Credit was Taken for TXV TXV wa: ystem E-::] of I—I Indicate the maximum a` owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow 1 x .06 uct Pressurization Test Results (GFM Cco. 25 PAT - 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) P QT -24 Compliance Credit was Taken for TXV TXV was PAGE 1 i F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -6R Site Address: 79-770 Viento Drive Permit Number: 0 .Tract Number: 29323 Plan #: 2Y Phase: 5 Lot Number: 26 Project: - Esplanade Builder: Lennar Homes system E::D of Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow 0 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x.06 , uc Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage 4 Check Box for Pass or Fail (Pass = 6% or Less) Pass Faill F -71T-24 Compliance Credit was Taken for TXV TXV was insta e System [:::] of Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow 0 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow X.06 uct Pressurization Test Results 100 x Test Leakage/ Fan Flow = % Leakage - Check Box for Pass or Fail (Pass = 6% or Less) Pass ai PT -24 Compliance Credit was Taken for TXV TXV was installed System of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow .0 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow I Ix .06 - uct Pressurization Test Results 100 x•Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Passl I Faill �T-24 Compliance Credit was Taken for TXV TXV was installed System � of Indicate the maximum aowa le Duct Leakage and the calculation used: , 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 ' 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow 0. 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 MR Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Passai QT -24 Compliance Credit was Taken for TXV TXV was installed I, the undersigned, verify that the abov iagnostic test results and the work I performed associated with the test(s) is in conformance with the requirement for mpliance credit. (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employMun certifying that diagnostic testing and installation meet the _ requirements for compliance credit.) VCL Team Heating & Air , Tests ignature, D installing u contractor(Co. Name Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro �. CD tL ertific�.fte oil Insulation Your Home has been insulated with CertainTeed Fiberglass Insulation pr dvicts, which are designed for today's safety standards and. tomorrow's energy requirement. r` CD Fiberglass: is inor,anic and therefore permanently noncombustible, so it does not have to be ireiated LO with fine-retardant chemicals that will likely loss Their effectiveness over; lime. It has not been treated CD with chernicaL: that can corrode wiring or metal. Fiberglass w dl not absoxb moisture nor will it settlle aver time as may other insulaticra materials. to . This also certifies that CertainTeed Fiber Glass In ulattion has been prof.ssionaily installed in this hosuc: ,t to provide the following thertral peirfomnanea: Job Name: Tspesti-� @Tsplanade Tract: - _29373 Phase:. .- Lot#.: _ ^l$ 2l� IMP: 2Y address: 79- 770 Vientm Dr., La Quinta, CA r Ceiling Area: R-38 Blo va Garage Ceiling: interior Walls: With Living Above — --- Overhangs: `Exterior INKalls: R-13 Unfaced Batts Ceiling: Garage Wall; Cantilevered: _ Inaccessible to Blow —� Floors NV/Living Above Subcola eton. i-Jfiasulat.lon, o., Inc. 600 S.4^ a tea I l (�16p 12 70L ir�hse 4463709 Signed Cotachitca Ortiz, Seertetarylrreasurer --or- 'J?. wd Jenkins, President—or- 0 M Lou Maions Officer rf:e R-means resistance to heat flow. The higher the. R- value,. the greater the insulating po.vrer. Ask your bwilcier for the fact sheet on R- values. Keep this certificate with your other valued papers. If you ever sell•this home, this certificate shouldl be passed on to the buyer. R CS) ru CD ' : ( � •rim.' ' _ � l ENERGY �<< CADI:C L. ' P0. Box 621, Ph/Fax (760) 564-2044 Rancho Miraoe, CA 92270 Ce 11:'(7601 250-1352 s Email: DESNRG no AOL.COtV1 i CERTIFICATE OF FIELD VERIFICATION•AND DIAGNOSTIC TESTING'Page -I of.7) CF -4R ' TAPESTRY @ ESPLANADE PH 5 DATE TESTED 10-11-04 Project Title Date 79-770 VIENTO DRIVE LA QUINTA CA. 92253 LENNAR HOMES Pro c Address Builder Name �+ ONY PASCANITE 909-275-0204 PLAN 2Y I UNIT' � Builder Contact Telephone Plan Number r a ALAN WEAVER 760-880-5504 GROUP 1 HERS Rater Telephone Sample Group Number '#CCNAWI8' 3266 1,0:12-04' 0 04 LOT 26=5 'Certifying Signature Date Sample Lot Number. Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 City/State/Zip: RANCHO MIRAGE, CA. 92270 Copies to: Builder, HERS Provider • _ '. HERS RATER, COMPLIANCE STATEMENT. t The house was: ® Tested ❑, Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I'certiy that the houses ideintified on this form comply with the diagnostic tested compliance requirements as checked on this form. ' 0 The installer has provided a copy of CF -6R (Installation Certificate. ® Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ® Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ® MINIMUM REQUIREMENTS•FOR•DUCT LEAKAGE REDUCTION COMPLIANCE •CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) t Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM 85 If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here . 2000 If fan flow is measured enter measured value `sere • Leakage Percentage (100 x Test Leakage/Fan Flow) = 4.25 Check Box for Pass or Fail (Pass=6% or less) ® 0 Pass Fail ® THERMOSTATIC EXPANSION VALVE (TXV) Yes ❑ No Thermostatic Expansion Valve is installed and Access is r provided for inspection ® ❑ �; CITY OF LA QUINTA BUILDING & SAFETY DEPARTMENT 'i or• 1����� 777-7012 INSPECTION REQUEST LINE 777-7153 Owner EENNAR HOMES OF CALIFORNIA Contractor LENNAR HOMES OF CALIFORNIA Permit Number 0402-356 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 79-770 VIEN`I'O DRIVE SFD - LOT 26, PLAN 2Y. PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH TYPE OF INSPECTION DATE INSP. TEMPORARY POWER SETBACKS U/G PLUMBING / WASTE U/G ELECTRICAL/ GROUNDING FOOTINGS / STEEL Ink CONCRETE SLAB DO NOT POUR CONCRETE UjNTR,,4191QN�gj ROOF NAIL / PRE -ROOF OKAY TO WRAP FRAMING COMBINATION ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL INSULATION' .01 COVER NO WORK UNTIL ABOVE SI ED INTERIOR GYP. BD. DRYWALL EXTERIOR LATH GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER (ALARMS/ BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER ELECTRICAL V(' PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT /' "J-pyOyll COMMUNITY DEVELOPMENT DEPT. 2-2 0 FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING � s . �: •'i f . 3 Ce t, to o Oc. r �r f -ccup,IJIn �ca Y .1 BUildin"g. &= Safety.DepartMent This Certificate.iiissued pursuant'to the'requirements of Sectioin 109.�of.the•.California Building Code, certifying that,' at, ;the time :-of issuance, ,, this, -structure•- was �. in compliance -`with , the , ,. I of. the' Building Code' and the`: various."ordinances -of the City` -regulating -building y construction • andUor use.'-, J BUILDING yADDRESS:•79-770 Viento'Drive- Use classification Single Family.Dwelling: Building Permit`No.:�0402=356 9 ,.- ;. :. •0ccupa6cy'Group: R-3 - =' ' - -Type of ConstructionNN Land Use Zone: RL - Owner -of Building: Lennof ai-Hoiiies California Address:, 78-401 C.Highway 111 1 }. • �� .� �. .- - '' ,City, ST,'ZIP:;La'Quinta, CA'92253 tt By: Daniel P. Crawford Jr.- fa: Date. 10/15/04 " � � . Y',-�' ' • �' �- •'' - . uilding Offic' . ' , o ' • . ( - - , t � I � � �r ~ - � ' •' 1 h yam, .f 1' .. � �. � •,� y �,;- ' POST IN'A CONSPICUOUS PLACE Not