Loading...
04-8330 (SFD)BUILDING & SAFETY DEPARTMENT P.O.. Box 1504 �: 4 ) (760).777=7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA. QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . t0_4.:_000-08330� ate 3/22/05 . . Property Address . . .I .79943 VIENTO DR APN: 609-380-999-45 -293234-„ Application description . . . DWELLING. -'SINGLE FAMILY.DETACHED Property Zoning . . ... . . . LOW.DENSITY RESIDENTIAL Application valuation . . . . 130681 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, STE C '78401 HIGHWAY 111, SUITE C LA QUINTA, CA LA QUINTA• CA 92253 LA QUINTA CA 92253 D WCC: AON RISK SRVC. WC: MWC11114.500 11/01/05 :kR1 205 CSLB: 728102 09/•30/06 _ CCC: B e Information---=-------.--------------Constructio L►Qt TyED YPE V - NON RATED Occupancy Type . . . WELLG/LODGING/CONG <=10 Flood Zone . . . ... NON -AO FLOOD ZONE Other struct info 'CODE EDITION 2001 CRC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG "` 447.00 PATIO SQ FTG 45.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 2121.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT - Additional desc Permit Fee 748.00 Plan Check Fee '. 121.55 Issue Date . . . . Valuation .. . . . ` 130681 Qty Unit Charge Per Extension BASE FEE r 639.50 31.00 3.5000 THOU BLDG 100,001-500,000 ""'� 108.50 ----------------------------------------------------------------------------- Permit MECHANICAL Additional desc Permit"'Fee . . . 39.50 Plan Check Fee 2.47 Issue Date . . . . Valuation . . 0 Qty Unit Charge Per Extension BASE FEE. -. .15.00 1.00 9.0000 EA MECH FURNACE <=100.K• `9:00 1.00 9.0000 EA MECH B/C <=3HP/100K'BTU 9.00 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: X4,8330 Applicant: c Applicant's Mailing Address: ch 04 VOICE (760) 777-7012 FAX (760) 7774011 INSPECTIONS (760) 777-7153 Date: S- 3/- i ct or Engineer: itect or Engineer's Ad ress: BUILDING PERMIT DECLARATIONS r LICENSED CONTRACTOR'S DECLARATION I hereby affirm under enalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Cle, and my Licen is in full force and effect. r� �, icense Class et—e_ns. No. lr9 1 wqt, Bate • t/ tractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the pfojects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. &l.have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is /�issped. My workers' compensate in!Ws ance carni¢(��jd,q isy nyrj��ej arrier f'1i>>/i fficicyNumber �VLV11��1.111 I certifythat, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE'LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lenders Address I AS APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building const/ruction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. �[e I `Vignature (Applicant or Agent): A JA44# i Page 2 Application Number. 04-00008330 Date 3/22/05 Qty Unit Charge Per Extension 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 71 Permit .. . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 98.18 Plan Check Foe 6.14 Issue Date . . . . Valuation 0 Qty 'Unit Charge" Per Extension BASE FEE 15.00 2121.00 .0350. ELEC NEW RES - 1 OR 2 FAMILY 74.24• 447.00, .0200 ELEC GARAGE OR -NON-RESIDENTIAL-'' 8.94 Permit . . . PLUMBING Additional desc Permit Fee- 152.25 Plan Check Fee.. 9..52 Issue Date ti Valuation 0 Qty Unit'Charge Per Extension. BASE FEE. '15.00 14.00 6.0000 EA PLB.FIXTURE .84.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1-:00 7.5000 EA PLB WATER HEATER/VENT 7.50 1..00 ..3.0000 EA PLB WATER,INST/ALT/REP 3.00 1.00 9.0000•EA PLB LAWN ,SPRINKLER SYSTEM 9.00 . 5.00: .7500 EA PLB GAS PIPE >=5 3.75 1:00 15.-0000 EA PLB GAS METER 15.00 Permit . . . . . GRADING PERMIT - Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date . . Valuation. 0 Qty` Unit Charge .Per Extension BASE FEE 15.00 Special Notes and -Comments SFD - LOT 45'. PLAN 3R, 2121 SF. PERMIT "DOES NOT INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH. 75-% PLAN CHECK FEE REDUCTION APPLIED FOR MULTIPLE.ISSUANCE OF SAME PLAN TYPE.,, - Other -Fees. . . . . . . . . . ART.IN PUBLIC PLACES -RES' .00 DIF COMMUNITY CENTERS -RES 97.00 Page; .3 Application Number ------------------------------------ . . . . Q4-00008330, Date 3/22/05 --- Other Fees -{--------------------------- DIF CIVIC CENTER - RES P ----- 366.00 ENERGY REVIEW FEE 12.16 DIF FIRE PROTECTION-RES,,97.0.0 GRADING PLAN CHECK -FEE 00_ DIF LIBRARIES"- RES 225,:00 DIF PARK MAINT__FAC:- RES 5:..00. DIF'PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 13.06 DLF STREET MAINT FAC -RES, 15.00 DIF TRANSPORTATION -. RES 1098.00 Fee summary Charged Paid Credited Due.* . Permit Fee Total 1052.93 00 00 1052.93: Plan Check Total 139.68 .00 .00" 139.68 Other Fee Total, 2;430.22 .00 ..`0.0 2430.22 Grand Total 3622.83 .00 .0.0 3622.83 OGT -21-2005 FRI 06,01 AM TEAM HEATING & A/C FAX NO. 9516943803 P. 26 HVAC INSTALLATIONS CERTIFICATE for Tested Duct Leakage & TXV Page 1 oft CF -6R Site Address: X79-943 Viento Drive, La Quinta, Ca 92253) Permit Number Tract Number. 29323 Plan #: 3 Phase: 13 Lot Number: 45 Project: Esplanade Builder: Lennar Homes An installation certmcate is required to be posted at the building site or made avalible for all appropriate inspections. Atter completion of tlnal inspection, a copy must be provided to the Building department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Eauioment ot Eviciency Duct Hearing Heating quip. CF -C Certitied Mfr Name Identicle (AFUE, etc.) Location Duct Load Capacity Type and Model Name Systems (>= CFAR) (attic, etc.) R -value (BTU / Hr) (BTU / Hr) ryan a iC Cooling Equipment of Elficiency Duct Cooling Cooling u p.-- I CFC Urtified Mfr Name Identice (SEER, eta) Location Dud Load Capacity Type and Model Number Systems (>TCF -1 R) (attic, etc.) R -value (BTU / Hr) (BTU I Hr) HP Bryant a 1, the undersigned, verify that quipmem listed above is: 1) is Ine acruai equipment Installed, z) equivalent to or more efficient than that specified i thpbuip te of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for resi en ) equipment that meets or exceeds the appropriate requirements for manufactured devices (from atie Regu all o Vorit 6 ere applicable, j Team Heating & Air, Inc Signature, DateInstalling Subcontractor ame OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: System of Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0,06) for Climate Zone 6 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow L 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow X.06 b -u -a Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Pass x ai y@T-24 Compliance Credit was Taken for TXV TXV was insta e x ys m = of Indicate the maximum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0,06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow X.06 u Pressurizatlon Test R ults FM 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Lass) PassI-aill =T-24 Compliance Credit was Taken for TXV TXV was installed PAGE 1 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro OCT ,21-2005 FR I 06:01 AM TEAM HEATING & A/C FAX NO, 9516943803 P. 27 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage,& TXV �Page 2 oft CF -6R Site Address: 79-943 Viento Drive, La Quinta, Ca 92253 Permit Number: 0 Tract Number: 29323 Plan #r+: 3 Phase: 13 Lot Number 45 Project: Esplanade Builder. Lennar Homes System r --J of Indicate the maximum a owa le Duct Leakage and the calculation used: 0,7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x FloorArea x (0.06) for Climate Zones 1 through 7 & 15 400 x (Cooling Capacity In Nominal Tons) x (0.06) 21.7 x (Heating Capacity In Thousands of output BTU per hour) x (0.06) Measured Fan Flow DW Pressurization Test Results (CFM V, 2 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) —IT -24 Cam Ilance Credit was Taken for TXV ' m of Indicate the maximum a awe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow—� Duct Pressurization Test ResultsFM a 25 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) pT-24 Compliance Credit was Taken for TXV ys em � of Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0,06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow I u Pressurization Test Results CFM a 25 PA) 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) T-24 Compliance Credit was Taken for TXV ys em = of Indicate the maximum aowa le Dud Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 6 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of output BTU per hour) x (0.06) Measured Fan Flow uc Pressurization Test Results (CFIVI S 20 PA) 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) QT -24 Compliance Credit was Taken for TXV x .06 x .06 x.06 x .06 TXV was TXV wa: TXV wa: P TXV was I, the undersigned, verify that the above dia ostic test results and the work:l performed associated with the test(s) is in conformance with the requirements for m Mance edi he builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees o su d ce Eying that diagnostic testing and installation meet the requirements for compliance credit.) Team Heating & Air, Inc ei s 3ignaiure, a e Installing subcontractor(Co. Name Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (If applicable) - Building Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro OCT 25,2005 15:53 BCI*TESTING,ril 000-000-00000 �. Page 18 C'aICERT>S Certified Rating October, 21 2005 "1'hi� Compliance rating is for the home located at: 79943 Vicnto.DriveI.a R I Vidue (luintil CA. 92253 Certificate Number: 1798351190 Date Inspected: October, 19 2005 010ERTS Rater: William Hctlsotl Pro used CC200407G HERS Analyst: N/A Builder/Developer:Lennar Orientation Ilomcs Project: ..� Tapestry (i!) SIM, Iaplanad� Plan Name: Plan 3 ` Lot Number: Opti Specifics about this home: GeneralIrffor'mation IfiAhlig rilvelo yc Conditioned Floor Area: 2121 Square beet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A N b f5 Surface Area Proposed Actual R 11 Value Factor R I Vidue Ll I Factor um el o . for res. Healing arul i oohng.�ystems Ileating Equipment: Furnace- 0.8 Pro used Actual Cooling Equipment: AC: 12 Orientation Area SHGC ll SIM, tl resrEp Value Value ' FX APPROVED AS PART OF SAMPLE GROUP (P91 of 1) IXAC Air• Lhvrib(ltiun Duct Location: Attic FIRM: BCI TESTING Duct Leakage Target: 6.0 Duct Insulation R -Value: 4.2 ADDRESS: 77-769 COUNTRY CLUB DRIVE, SUITE I PALM DESSERT, CA. 92211 Air lryiltrauon PHONE: 760-772-2964 + Blower Door Target: 120.0 Waler Ileafin f SS sleet l'rn se(f CERTIFYING SIONATURE DATE TY Size Fuel EF Distribution t , Wlilel IIE.'Ul!l7' S)StBIl1 Actual TY Size Fuc! EF Distribution " Cerifcate of Insulation # , Yom hwhe has been insulated WIM .titin Mme Fiber mon produc K'whic h are designed • for todaft safely girds and tmnoffoWs energy requirements. - Fiberglass Is iriorganic and therefore pemtarmtly noncombustible, so it does not have to be Mudded ` with fle-retardant chem that will Iticely lose Hirer effectiveness overtime. it has rot been treated uuhh chemicals fiat can corrode wiring or metal. Fiberglass will not absorb rnoisture nor wiB It settle over tirne as may outer insulation materials. IL This also oertifies that insulation have been professionally installed in this home to provide the Ln following thermal performarm- Lenn r* Maines u~i .lob Name: TAY Ezra& Tract 29323 Ph" 3C Phase: 43 A Z' Lot No: 45 .lob Address: SFR-7"43 Yfsnio Dr, Le Qukft CA 0 Ceiling Area: R-W blown a batt Woulauun Gar"* Ceiling: Non�4ecass: WM LM" Above A Sloping Aram Exterior Wags R43 ba t instfation oveAMP: Accew Attic: With Living Above Betwom Flom: MtsMor Wails: R-19 Batt insulation N Subcontractor J Insulation, Inc. . ...0 m 72-227 Adelaid St, Thousand Palms, CA 92276 . Ln 01 Sig V, N L° _ Mike Dkkemmn, General AftnaW - Pah" Spifts Dfvisim LO CO R freeans resistance to heat flow. The h the R-value, the r the r. 8� ksulating power. CD - Ask your builder for the fact sheet on R-values: Keep this oertificate with your other N valued papers. if you ever set this home, this cerbftcate should be passed on to the buyer. m