Loading...
11-1229 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253 ` BUILDING & SAFETY DEPARTMENT 'BUILDING PERMIT Application Number: 11-00001229 Property Address: 56585 VILLAGE DR APN: 7647050-.014- .. Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 347369 " Owner: BILL LAWSON 56585. VILLAGE DR LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/01/13 Contractor: LFI:NAN g G 12013Applicant: Architect or Engineer: BARTER, BRUCE77 E. TORREMOLINOS DRIVE RANCHO MIRAGE, CA 92270OF AQ01NTA(760)851-7356 CEDEPT, Lic. No.: 931031 LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION. I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business a dProfessi als Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Cla o.: 931031 for by Section 3700 of the Labor Code,, for the performance of the work for which this permit is ' 2 issued. . (-"-'Date: l%rrContractor. _ _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION. insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EXE Policy Number EXEMPT following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance,'also requires the applicant for the - person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if. I should bee�eltjeefto.t4e_ vv ers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3 00 of the Labor Code, I sh it those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by _ any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$500).: Date: .Applicant: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and �- - - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WAR NIN A, L U RE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT ' (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for . pursuant to the Contractors' State License Law.)• whose benefit work is performed under or -pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced - __ • - _ _ _ _ - - _ _ - _ _ . - within 180 days from date of issuance of such permit, or cessation of work for 180 days will ,subject .. . __. CONSTRUCTION LENDING AGENCY permit to cancellation. - - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to building construction authorize representatives - of this county t enter upon the above-mentioned property iurposes. Lender's Name: - - ' CDate: Signature (Applicant or Agent):— Lender's Address: - `-- 1 LQPERMIT - - Application -Number 11-00001229 ------ Structure Information .3,867SF DWELLING/VB/RES-3/CLASS•A-FR/13D----- Other struct info . CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS 13D GARAGE.SQ FTG 753.00 _ PATIO SQ FTG 925.00 NUMBER OF UNITS. 1.00 1ST FLOOR SQUARE FOOTAGE 3867.00 Permit BUILDING PERMIT Additional desc . Permit Fee 1507.50' Plan Check Fee*. 979.88 Issue Date Valuation `347396 Expiration Date 7/31/13 Qty Unit Charge Per Extension BASE FEE 639.50 248.00 3.5000 THOU BLDG 100,.001-500,000 868..00 Permit MECHANICAL Additional desc Permit Fee 149.00 Plan Check Fee 37.25 Issue Date Valuation. 0. Expiration Date . 7/31/13. Qty Unit'Charge Per Extension BASE FEE 15.00 y 3.00 .. 9.0000 EA MECH FURNACE <=100K_ 27.00 1.00 9.0000 MECH B/C <=3HP/100K "BTU 9.00 2.00 16.5000 _EA EA MECH B/C >3-15HP/>100K-50OKBTU 33.00 9.100 6.5000 EA MECH VENT FAN 58.50. -1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit. ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . 180:41 Plan Check Fee 45.10 Issue.Date Valuation .. . . . 0 •Expiration Date 7/31/13 - Qty Unit Charge Per Extension BASE FEE 15.00 3867.00 .035Q ELEC NEW RES - 1 OR 2 FAMILY 135.35 753.00 .0200 ELEC-GARAGE OR NON-RESIDENTIAL 15.06 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 LQPERMIT • - - - Application Number ". . . 11-0000.1229 Permit . . .PLUMBING , Additional desc . Permit Fee 234:75 Plan Check Fee .. 58.69 ."Issue Date Valuation 0 Expiration Date 7/31/13 Qty" Unit Charge Per Extension" BASE FEE 15.00 26.00 6.0000 EA PLB FIXTURE 156.00 " 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA" PLB WATER.HEATER/VENT 15.00 1.00 3.0000 EA" PLB WATER INST/ALT/REP. 3.00 1.00 9.0000 EA, PLB LAWN SPRINKLER SYSTEM 9.00 9.00 .7500"EA PLB GAS PIPE >=5 6.75 • 1.00 15.0000 EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc . Permit Fee. 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 7/3.1/13 Qty Unit Charge Per Extension BASE FEE 15.00 Special Notes and •Comments ` 3,867SF DWELLING/VB/RES-3/CLASS-A/13D- 4ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK-WALLS, POOL, SPA, OR WATER FEATURES. 2010 CALIFORNIA BUILDING CODES. January 23, 2013 4:24':34' PM AORTEGA Other Fees ART IN PUBLIC PLACES-RES 368.42 BLDG STDS ADMIN (SB1473) 14.00 DIF COMMUNITY CENTERS-RES 104.00 ' DIF.CIVIC CENTER- RES 1089.00 " ENERGY REVIEW."FEE 97.99 DIF FIRE PROTECTION-RES 612.00 GRADING'.PLAN CHECK FEE 15.00 DIF LIBRARIES -.RES 334.00 MULTI-SPECIES (MSHCP) .FEE 1254.00 DIF PARK MAINT FAC _ RES 51.00 -DIF PARKS/REC_- RES 1773.00 'STRONG MOTION (SMI) - RES 34.74 Application Number 11-00001229: (- -------------------- - - Other Fees .. . - - ------------- . . . .. --------------------------- DIF STREET MAINT TAC-RES --------- 158.00 bIF TRANSPORTATION - RES 3592.00 Fee summary Charged Paid Credited Due - Permit.Fee Total- 2086.66 .00 .00 2086.66 _ -.'_Plan. Check Total- .-1120.92 500.00. - .00 _ _ 620..92-- Other Fee Total 9497.15 .00 .00 9497.15 Grand Total 12704.73 500.00 00 12204.73 ~:Tit P.O. BOX 1504 APPLICATION ONLY Building' _5�5 V C L 78-495 CALLE TAMPICO Address 67 E J,eLA QUINTA, CALIFORNIA 92253 ' .;, Owner BUILDING: TYPE C NS OCC. GRP. Mailing r^ i� -: , a ®•�� 9T i>/Ll Address 7 I A.P. Number TelLegal Description Contracto - �= — "'�_ - J - Project Description _Sv �Jb d � " I 10 et✓LC.- Addre• ::State Lic. - _. ' - - - ' 760 gip-dgb3 c y Sq. Ft: No. NO. DW. & Classif s. ; �1 r;. Lic. #; Size 3 ��� Stories Units Arch.,` Engr.;: / ( New 2loo, Add ❑ Alter ❑ Repair ❑ Demolition ❑ Designer + Address ' Tel. ` L .Cit plZip State o. Lic. # • LICENSED CONTRACTOR'S DECLARATION - r - - ..•'i + I hereby affirm that I am icen under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of th u ' ss and Professions Code, and my license is in(J1force agd effect. 0 / I I A n. 4 SIGNATUR V DATE - ' • '-� ^ ' OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also • PERMIT AMOUNT requires the applicant for such permit to file a signed statement that he is licensed pursuant to 'the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis "Plan Chk. Dep. for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects' the applicant to a civil penalty cf not more than five hundred dollars ($500). Plan Chk. Bal. Y O I, as owner of the property, or my employees with wages as their sole compensation, will do " the work, and the structure is not intended or offered for sale. (Sec. 7044,' Business and Profes- # Const. sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided Mech. A that such improvements are not intended or offered for sale. If, however, the building or im• t �. Electrical • provement is sold within one year of completion, the owner -builder will have the burden of t 1 , proving that he did not build or improve for the purpose of sale). ° "Plumbingr r , f ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct i. the project. (Sec. 7044, Busiress and Professions Code: The Contractor's License Law does SMI i ev 1 not apply to an owner of property who builds or improves thereon, and who contracts for such . projects with a contractor(s) licensed pursuant to the Contractor's License Law) Grading _ • " ❑ 1 am exempt under Sec. B. & P.C. for this reason ; IA Driveway Enc. t (>.+' ''r .r. �. UJIN -r�:`yu Date Owner Infrastructure' - --- "— WORKER'S COMPENSATION DECLARATION. • r R hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's *; . Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No.- Company , O Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM TOTAL • WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation ' REMARKS ` or less). - I certify that in the performance of the wo which this permit is issued, I shall not ' employ any person in any manner so as to asubject to Workers' Compensation Laws of Califor fat c F r Date NOTICE TO APPLICANT If, after mak g this Ce ificate of Exemption you should become' subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith . comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: • CONSTRUCTION LENDING AGENCY + Front Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work Rear Setback from Rear Prop. Line for which this permit is issued. (Sec. 3097, Civil Code.) Lenders Name Side Street Setback from Center. Line Lenders Address Side Setback from Property Line This is a building permit when properly filled out, signed and validated, and is subject to . expiration if work thereunder is suspended for 180 days. ` - I certify that I have read this application and state that the above information is correct. FINAL DATE INSPECTOR I agree to comply with all city and county ordinances and state laws relating to building t construction, and hereby authorize representatives of this city to enter the above-mentioned `. a property for inspection purposes. ♦ Issued by: Date c - Permit Signature of applicant Date Mailing Address Validated by:` City, State, Zip - - . r' Validation f WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE r '4Coac!hella Valley Unified School District This Box For District use only .83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID r (760) 398-5909 - Fax (760) 398-12240. AREA: ` r AMOUNT / 70. LEVEL ONE AMO .'T: LEVEL &0 AMOLNT: MITIGATION AMOUNT: COMMRND. AMOUWT: GATE: RECEIPT: fHECKM: � I INITIA D CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Bill Dittman - Date: 05/1(106 Owner's Name: Bill Dettman Phone No. (530) 613-1173 Project Address: 56-585 Village Dr., La Quinta, CA Project Description: 1 Single Family Dwelling APN: 764-050-014 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of -Building Area: 3,867 sq. Ft. Certification of Applicant/Ownersi The person signing certifies that the above information i5xaprectand makes this stateinent under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/ eveloper. Dated: 05/10%06 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN :ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code • , Gov. Code Project Agreement Existing Not Subject to Fee 17620: 65995. Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 3;867 sq. ft. Amount per Sq.Ft. S 2.63 Amount Collected $ '10,170.21 Building Permit Application Completed: Yes/No y By: Carey M.•Carlson, Asst. Supt., Business Services ,. Certificate issued by: Leticia C. Torres Facilities Analyst Sig natu NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEME T OF FE S Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day, period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in'regard to such Fees or the validity thereof, commences with.the payment of the fees or performance of any other. requirements as described in Section 66020 of the Government code. Additionally, the Amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As In the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate or Compliance... - 1/16103 T BrLt ih :OCC,User :3600 ORANGE COAST TITLE CO. !l Sa51 o - ed RECORDING REQUESTED BY AND WHEN RECORDED MAIL TO: William Lawson ( uu ,4k as S Comment: Station Id :XX52 r DOC # 2011-0133740 03/25/2011 e3:04P Fee:35.00 Page I of I Recorded in Official Records County of Riverside Larry U. Ward Assessor, County Clerk 8 Reeorder �1�1111111f1 1111111111{1111111111111111111111111111111 . V I A I l I 408 I 4Zb rt,vrc N(;Uht SMI- I NGMG --"- A.P.N.: JD 764-050-014-ITRA k: Uo� Order T: CTY UNI INTERSPOUSAL TRANSFER GRANT DEED (Excluded from reappraisal under California Constitution Act 13 A Let seq.) DOCUMENTARY TRANSFER TAX NONE This is an Interspousal Transfer and not a change in ownership under §63 of the Revenue and Taxation code and Grantor(s) has(have) checked the applicable exclusion from reappraisal: ( ] From Joint Tenancy to Community Property [ ] From One Spouse to Both Spouses [X] From One Spouse to the Other Spouse : [ ] From Both Spouses to the Other Spouse ,a34 [ ) Other: FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, GRANTOR Paige Lawson, Spouse of Grantee hereby GRANT(S) to William Lawson, a married man as his sole and separate property. the following described property in the City of La Quinla, County of Riverside State of California, - Lot 55 of Tract 28983, in the City of La Quinla, County of Riverside, as per map recorded in Book 285, Page(s) 76-82, of Maps, in the Office of the County Recorder of said County. Document Date: February 18. 2011 Paige Lawson kk SPATE OF k l )SS . COUNTY OFp'gv) On before me a notary public in and for said state, personally appearedwho proved me on the basis of satisfactory avid ce to be the persokwhose nam A�k sscribed to the w``it'h'in instrument anal acknowle\dged to me that h she/ ey executed the same in s/he their authorized capacity , om1 that by hi he their signature(c) on the instrument the persAi(s), or the entity upon behalf of whi t Y"C acted. executed the instrument. 1 cenify r PEN LTY OF PERJURY under the la s of the State of California that the foregoing paragraph is true and correct. W NESS d 1 AUG 21 2012 J. HATHAWAY , S nature rAn Camrtshaion/1812630 Motuln Puhlk - Ctllfonde (Seal) 10Rlvew C nOaM)r Conan. ExWros Nov 7 2011 RIVERSIDE,CA Page I of I Printed on 8/16/2012 1:41:23 PM Document: DD 2011.133740 . Bra.;1'&h :OCC,User :3600 Comment: Station Id :XX52 7 TITLE 10. MANGE CO A S RECORDING REQUESTED BY DOC # 2011-0133739 03/25/2011 03:04P Fee:18.00 AND WIZEN RECORDED MAIL TO: Page 1 of 2 Doc T Tax Paid Recorded in Official Records William Lawson County of Riverside C� �5 Larry U. Yard, Assessor, County Clerk & Recorder �- C��,:�.,� G,�- 9�a s3 I IIIIII 1111111 IIT III 11111!1 III IIIIIII Ill IIIII IIII 1111 . A.P.N.: 764-050-014-ITRA k: -Ardertdtr. " GRANT S R I U P E SIE I DA I MISC LONG RFD COPY A L 465 1 426 PCO COR SMF NCHG ,\ V T: CTY UNI THE UNDERSIGNED GRANTOR(s) DECLARE(s) THAT DOCUMENTARY TRANSFER TAX 1S: COUNTY $154.00 [ X 1 computed on full value of property conveyed, or 1 computed on full value I ss value of liens or encumbrances remaining at time of sale, [ 1 unincorporated area: 1'K1 1 City of La Quinta , and -034 + FOR VALUABLE CONSIDERATION, Receipt of which is hereby acknowledged, • William P Dettman, a Married man as his Sole and Separate Property hereby GRANT(S) to William Lawson, a Married Man as his Sole and Separate Property the following described prop y in the City of La Quinta, County of Riverside State of Califomia; See Exhibit " : at(ac e d made a part hereof. r illia n ettman Doctmtent Date: February 19, 2011 STATn OF CAI 1 )SS COUNTY OF ) On before t�C� , , a notary pt:blic in and for said state, personally appeared who proved to me on the basis of satisfacto evidence to be the personN whose nam%( i. re wbscribed ro rhe within instrument and acknowledged to me th-Gshe/they executed the sa e i hi her/their authorized capachy�e), and that b hi edtheir signature on the instrument the person, or the entity upon behalf of , which the person acted, executed the instrument. ' \\\ 1 certify PENALTY OF PERJURY under the laws of rh Stam of California that the foregoing paragraph is true and correct. WrltNESS s Sig inn J. HATHA71A Comedaelon tr191253"01 Maury Public - Seal) RlvenldeCty Cotten. a Nov 7.2011 r ' t Mail Tax Statements to: SAME AS ABOVE or Address Noted Below RIVERSIDE,CA' `! Page I of 2 Printed on 8/16/2012 1:41:23 PM Document: DD 201 1.133739 Branach :OCC,User :3600 Comment: Station Td :XX52 �r The Management Trust ..., MONARCH GROUP DIVISION January 30, 2013 WILLIAM LAWSON t ' 80-733 CHERRY HILLS LA QUINTA, CA 92253 RE: Architectural Submittal for 56-585 VILLAGE -DRIVE _ !• Account#: 673857 Dear Homeowner,!? ! ? The- Architectural' Review Committee for • VILLAGE AT THE PALMS has reviewed and APPROVED your revised architectural submittal_ plans for new home construction per the plans, submitted based on the following conditions: 28' set. back from property line is to be met and minimum floor area and lot coverage shall not exceed 40.01%. ' ARC approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations or- restrictions. r 'restrictions. The ARC shall not be responsible for reviewing,, nor shall .its approval of any plans or design, be deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving such plans • and specifications, neither the ARC, the Members thereof, the Association, any Member thereof, their Board of Directors, ' any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in .the construction or improvement from such plans or specifications. As provided in the CC&R's neither the ARC, the Association,. the Board of Directors or the. Association or any Members thereof, not the Declarant or Developer shall be liable to any Member, Owner, Occupant,`or•other. person or entity for any damage, loss or prejudice suffered or claimed on account of (1) the . f approval or disapproval of any plans, drawings, or specifications, whether or not defective, or (2) the; construction or r performance of any work whether or not pursuant to the approved plans; drawings, or specifications. Your patience and cooperation with the architectural review process is . appreciated. If you have: any questions, please contact the association at (760) 776-5100. Sincerely, I On behalf of the VILLAGE AT THE PALMS Architectural Review Committee4.The Management Trust - Monarch Group Division ' cc: Board of Directors , Unit File 39755 Berkey Drive, Suite'A, Palm Desert, CA 92211 4 CONNECTING PEOPLE TOTHE PROMISE pH: 760.776.5100 FAX: 760.776.5111 www.managemenurust.com } F— O IL 0 Q I m> � U yi H N L m � � cn z `LL a� Loi a v o t- a w t w N_ N I Z a Lr., 'W V W J � Y r., z °z U w J Y a cn Z a � w Li. J w 0 0 0 z Q W Y Q } y !.0 � S �U r o v sv a r n. c p U Q Q . Q LA pROTE�T�o F� FARE PRp� tip, W> C16 z 4( EXP. &31 12 �TF OF CAL\�R�' c.i a ' 0 V c� ❑- c 4j k tQ �a M U Z OL !tt l�U Z p �i - Q-�� o LO � q � O 111 ,.q 0 zw.t O z 3w - 0 Wui N "' a I i I r., z NOV-06-2013 WED 05,40 PM RIVERSIDE COUNTY FIRE. FAX NO, 17608637072 P,.01 Riverside County Fire Department Fire Protection Planning Section,,. Rlvorldo Offlca: 2300 Markel St, Ste. 150, Rlvorlda, CA 02501 ft (951) 855-4777 Fax (851) 856.41188 palm Desen orfWe: 77.933 Las Montahw Rd., H 201 Palm Dc5en, CA 92211-4131 Ph. (760) 663-8886 Fax (76D) 863-7072 - r Fire Department Clearance/Release Date: 11 /6/2013 To: LA QUINTA B&S Fax: .► TracVParcel Map #: THE PALMS Permit/Lot M L011 -RS -020 5. Job Site Address: ` 56585 VILLAGE DRIVE City, State, Zip LA QUINTA �I Final For Recordation Final for Alarm System Final. for Fire Suppression System Shell Final Only (No Tenant) - rl Release For Residential Sprinkler Installation - r] Building Plan.Check Fees. Paid, Water Requirement Met- if water applicable r. ❑ _ Building Plan Check Fees Not Paid Residential Sprinkler Plan'Check Fees Paid Residential Sprinkler Plan Check Fees Not Paid ❑ Other Fees ❑ Fees Not Required 4 If you should have any questions, please contact the appropriate Riverside County Fire Protection Planning office for further assistance. KOHL HETRICK Print Name of Plan Reviewer/Inspector Approved Release PSent By: Print Name Form C-Roulsed 3I01/2C12 UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE C OAC H E LLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSIN ORE LA QUINTA. MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUX CSD SAN JACINTO TE M EC U LA' WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 ...Arvoksm COUNTY FVRZ D '. IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste: #201, Palm Desert, CA 92211-4131 a Phone (760) 863-8886 • 'Fax.(760) 863-7072 www.rvcfi.re.org November 14, 2011 Innovative Fire Protection 8779 Cottonwood Ave #101' 20 / Santee,. CA 92071,: 11 Re: Residential Fire Sprinkler Plan Review The Lawson Residence 56-865 Village Dr. La Quinta, CA The above referenced sprinkler plans have been reviewed and are. acceptable by the Riverside County Fire Department and are approved with the following conditions: 1) Approval of these plans does not include the piping of the underground system. . 2) Permanently marked identification signs shall be attached to all control valves. 3) A'sign shall be located adjacent to the alarm bell worded as follows: SPRINKLER FIRE ALARM - WHEN BELL RINGS CALL 911 4) A warning sign, with minimum'/4 inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shutoff the -Water to the.fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves,_ shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 11/4/2011 C:\HASS74\C4663.SDF 4JOB TITLE: LAWSON RESIDENCE TWO HEAD CAL'C-M. BEDROOM WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ_'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.' TAG (PSI).. (PSI)' (GPM). (PSI) (GPM) (PSI) 1 81.0 75.6 500.0 81.0 31.2 65.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM " TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE -STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT') (PSI) (GPM) 1 0.0 SOURCE 65.5 31.2 2 0.0 - - 58.2 - - 2A0.0 - - - - 45.2 - - - R. 0.0 - - - 43.9 - - - P 0.01 32.9 - - 3A 0.0 - - - - 31.7 - - - j 3B 1.0 HOSE STREAM 27,.8 5.0 3 3.5 - - - - 24.5 - - 4 6.5 - - - - 21.5 - 5: 10.5 - - 15.9' 6 12.5 - - - -' 10.4 - 6A 12.0 - 10.6 - - 7 12.5 - - - 9.3 - - 7A 12.0 K= 4.30 9.1 13.0 8 12.5 - - 9.3 - - - 8A 12,.0 K= 4.30 9.3 13.1 NOVZ4?0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/4/`2011 C:\HASS74\C4663.SDF JOB TITLE: LAWSON RESIDENCE TWO HEAD CALC=M. BEDROOM PIPE`DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM)' FL/FT (PSI) (Pipe: 1 31:2 0.995 PL 20.00 PF 7.3 1 0.0 SRCE 65.5 .(N/A) 12.9 150 FTG TG PE 0.0 2 0.0 0.0 .58.2 0.0 0.253 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE -2- 0.0 0.0 58.2 0.0 13.0 psi, 31.1 gpm 2A 0.0 0.0 45.2 0.0 'Pipe: 3 31.1 1.025 PL 3.00 PF 1.3 2'A 0.0 0.0 45.2 0.0 12.1 150 FTG E PE 0.0 'R 0.0 0.0 43:9 0A . 0.219 TL 6.00 PV Pipe: -4 FIXED PRESSURE LOSS DEVICE R 0.0 0.0 43.9 0.0 11.0 psi, 31.1 gpm P 0.0 0.0 32.9 0.0 Pipe: 3 31.1 1.590 PL 35.00 PF 1.2 P 0.0 0.0 32..9 0.0 5.0 150 FTG 4L PE 0.0 3A 0.0 0.0 31.7 .0.0 0.026 TL 47.00 PV .Pipe,: 6 31.1 1.265 PL 1.0.00 PF 3.5 3A 0.0 0.0• 31.7. 0.0 8.0 150 FTG E2TC PE -0.4 " 3B 1.0 H.S. 27:8 5.0 0.079 TL 44.00 PV Pipe: 7 26.1 1.025 PL 3.00 PF. 2.2 -3B 1.0 H.S. 27.8 5.0 10.2 150 FTG ET PE -1.1 3 3.5 0.0 24.5 0.0 0.158 TL 14.00 PV Pipe: 3 26:1 1.049 PL 3.00 PF 1.7 3- 3.5 0.0 24.5 0.0 9.7 120 FTG C PE -1.3' 4 6.5 0.0 21.5 0.0 0.214 TL 8.00 'PV - Pipe: a 26.1 1.101 PL 24.50 PF' 3.9 - 4 6.5 0.0 21.5 0.0 8.8 150 FTG E3R -PE -1.7 5 10.5 0.0 15.9 0.0 0.112 TL 34.50 PV Pipe: 10 13.7 1.101 PL 97.50 PF 4.6 5 10.5 0.0 15.9 0.0 4.6 150 FTG 2E5T PE -0.9 6,. 12.5 0.0 10.4 0.0 0.034 TL. 136.50 PV Pipe: 11 0.0 1.101 PL 0.50 PF 0.0 6-• 12.5 0.0 10.4 0.0 0.0 150 FTG TR PE 0.2 6A 12.0 0.0 10.6 0.0 0.000 TL 6.50 PV Pipe: 12 13.-7 1.101 PL 29.50 PF 1.1- 6 --2.5. 0.0 10.4 0.0 4.6 150 FTG 3R PE 0.0 7 _2.5 0.0 9.3 0.0 0.034 TL 32.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 ; DATE: 11/4/2011 C:\HASS74\C4663.SDF' JOB TITLE: LAWSON RESIDENCE TWO HEAD CALC-M. BEDROOM PIPE TAG Q(GPM) DIA(IN) LENGTH- PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.0 1.101 PL 2.50 PF 0.4 7 12.5 0.0 9.3 0.0 4.4 150 FTG 2TR PE 0.2 7A 12.0 4.3 9.1 13.0 0.031 TL 13:50 PV Pipe: 14 0.7 1.101 PL 10.00 PF 0.0" 7, 12.5 0.0 9.3 0.0 0.2 150 FTG R .PE 0.0 8 12.5 0.0 9.3 0.0 0.000 TL 11.00 PV Pipe: 15 13.1 1.101. PL 0.50 PF 0.2 8 12.5 0.0 9.3 0.0 4.4 150 FTG TR PE 0:2 8A 12.0 4.3 9.3 13.1 .0.031 TL- -6.50 PV Pipe: 16 -12.5 1.101 PL 147.50 PF 5.7 8- 12.5 0..0 9.3 0.0 4.2 150 FTG 4E5T PE 0.9 5 10.5 .0.0 15.9 0.0 0.028 TL 200.50 ',,PV NOTES (HASS): (1) Calculations were performed by the'HASS 8.2 computer program under license no. 16080621 granted by HRS Systems, Inc.. 208 South. Public Square Petersburg, TN 37144 (,931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.008 gpm and a maximum imbalance at any node of 0.114 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/4/2011 C:'\HASS74\C4663.SDF ,JOB TITLE: LAWSON RESIDENCE TWO HEAD CALC-M. BEDROOM PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 150 . Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 1.265 5.00 9-.00 2.00 11.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths'in Feet - (in) E T L C B G A D Ell Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 .0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D . Ell Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0:00 . SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 -Dp,TE:. 11/4/2011C:\HASS74-\C:4663.SDF ,JOB TITLE: LAWSON RESIDENCE TWO HEAD CALC-M. BEDROOM WATER SUPPLY ANALYSIS Static: 81.00 psi Resid: 75.60,psi Flow:;500.0 gpm r . 80 1: G A U G 2 :E' 60. C r P R •E ; S 40.0 S' U R E •. (; 20.0 ,p • l , r 0.0 -14.7 • LEGEND Available ;pressure 80.97 ps-i ' @ • 31.2 gpm Required pressure 65.54 -psi @ 31 2 ;gpm A. Source Supply"Curve B...System D6mand Curve t . 4 .. 20C300400 500 600 700 800 , 900 1000 J +' ,FLOW (GPM) ! - SPRINKLER -SYSTEM HYDRAULIC ANALYSIS Page 1 !.` DATE:f11/4/2011 C:\HASS74\C4663.SDF ♦:'JOB TITLE: LAWSON RESIDENCE ONE HEAD'CALC-M. BATHROOM - - WATER'SUPPLY DATA y SOURCE STATIC RESID.FLOW AVAIL. TOTAL REQ'D ' NODE PRESS. PRESS. -@ PRESS. @ DEMAND PRESS. , '.TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) , 81. 0 75.6 5001.0 '. 81.0' 23.0 61.3 `,:AGGREGATE FLOW ANALYSIS: Y ',",.TOTAL . FLOW AT SOURCE 23.0 GPM ` TOTAL•HOSE STREAM ALLOWANCE AT SOURCE PM 0.0 GPM- OTHER OTHER HOSE STREAM ALLOWANCES 5.0 GPM _ TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 18.0 GPM 1•-` NODE ANALYSIS DATA NODE TAG ELEVATION., NODE TYPE PRESSURE DISCHARGE - (PSI) (GPM) .. -1 0.0 SOURCE .. 61.3 23.0 2 0.0 - - - - 57.2 - - - 2A ` •0.0 - - - - - 44.2 P• 0.0 - - - - 32.4 - - -• 3A'• 0.0 - - - - 31.7 - - - 3B 1. 0 • • HOSE 'STREAM '29.3 5.0 3 3.5 - - -` - 27:1 - - - ' 4 6.5 - - - - 25.0 510.5 - - - - 21.3 6 ; 12.5 - - - - l 17.7 - - - �. • 6A Y 12.0 K=-4.30 17.5 18`.0. - 7 12.5 - - - - - 18.0 - - - 7A', 12.0 - - - - 18.3 - - _ 8 12.5 - - - '- 18.2 8A' r 12!10 - - - -_ 18.4 I A SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 1 DATE: 11/4/2011 C:\HASS74\C4663.SDF, }JOB TITLE: LAWSON RESIDENCE ONE HEAD CALC-M. BATHROOM PIPE DATA - PIPE TAG Q(GPM)' DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI), Pipe: 1 23.0 0-.995 PL 20.00 PF 4.2 1 0.0 SRCE 61.3 (N/A) 9.5 150 FTG TG PE 0.0' 2 0.0 0.0 57.2 0.0 0.144 TL 29.00 PV Pipe: ? FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 57.2 0.0 13.0 psi, 23.0 gpm 2A 0.0 0.0 4.4.2 0.0 Pipe: 3 23.0 1.025 PL 3.00 PF 0.7 2A 0.0 0.0 44.2 0.0 8:9 150 FTG E PE 0.0 R 0.0 0.0 43.4 0.0 0.125 TL 6.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE R 0.0 0.0 43.4 0.0 11.0 psi, 23.0 gpm P 0.0 0.0 32.4 0.0 Pipe: 5 23.0 1.590 PL 35.00 PF 0..7 P 0.0 0.0 32.4 0.0 3.7 150 FTG 4L PE 0.0 3A 0.0 0.0 31.7 0.0 .0.015 TL 47.00 PV Pipe: 6 23.0 1.2.65 PL 10.00 PF 2.0 3A 0.01 0.0 31.7 0.0 5.9 150 FTG E2TC PE -0.4 3B 1.0 H.S. 29.3 5.0 0.045 TL 44.00 PV Pipe: "' 18.0 1.025 PL' 3.00' PF 1.1 3B 1.0 H.S. 29.3 5.0 7.0 150 FTG ET PE -1.1 3 3.5 0.0 27.1 0.0 0.079 TL- 14.00 PV Pipe: E 18.0 1.049 PL 3.00 PF 0.9 3 3.5 0.0 27.1 0.0 6.7 120'FTG C PE -1.3 4 6.5 0.0' 25.0 0.0 0.107 TL 8.00 PV Pipe: S 18.0 1.101 PL 24.50 PF 1.9 4 6.5 0.0 25.0 0.0 6.1 150 FTG E3R PE -1.7 5 30.5 0.0 21.3 0.0 0.056 TL 34.50 PV Pipe: 10 10.4 1.101 PL 97.50 PF 2.8 5 10.5 0.0 21.3 0.0 3.5 150 FTG 2E5T PE -0.9- 12.5 0.0 17.7 0.0 0.020 TL 136.50 PV Pipe: 11 18.0 1.101 PL 0.50 PF 0.4 6 12.5 0.0 17.7 0.0 6.1, 150 FTG TR PE 0.2 6A 12.0 4.3 17.5 18.0 0.056 TL 6.50 PV Pipe: 12 -7.6 1.101 'PL 29.50 PF 0.4 6 12.5. 0.0 17.7 0.0 2.6 150 FTG -3R PE 0.0 -7 12:5 0.0 18.0 0.0 0.011 TL 32.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/4/2011 C:\HASS74\C4663.SDF 'JOB TITLE: LAWSON RESIDENCE ONE HEAD CALC-M. BATHROOM PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV.- NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 0.0 1.101 PL 2.50 PF 0.0 7 12.5 0.0 18.0 0.0•. 0.0 150 'FTG 2TR PE 0.2 7A 12,.0 0.0 18.3 0.0 0.-000 TL 13.50 PV Pipe: 14' '-7.6 1.101 -PL 10.00 PF 0.1 7 12.5 0.0 18.0 0.0 2.6 150 FTG R PE 0.0. 8_. 12.5 0.0 18.2 0,0 0.011 TL 11.00 PV Pipe: 15 0.0 1.101 PL 0.50 PF. U. -O 8 12.5 0.0 18.2 0.0 0.0 150 FTG TR PE 0.2' 8A, 12.0 0.0 18.4 0.0 0.000 TL 6.50 PV Pipe:. 16 -7.6 1.101 PL 147.50 PF 2.3 8 12.5 0.0 18.2 0.0 2.6 150 FTG 4E5T PE 0.9 5 10.5 0.0 21.3 0.0 0.0.11 TL 200.50 PVA! NOTES (HASS): (1) Calculations were performed by the HASS 8.2 computer program] under license no. 16080621 granted by . HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average ,imbalance at each node of 0•.001-gpm and a maximum imbalance at any node of,0.007 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 9.5 ft/sec at pipe,, 1. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) -PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP �•r' SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 t! D$TE: 11/4/2011 C:\HASS74.\C4663.SDF °JOB TITLE LAWSON RESIDENCE ONE HEAD CALC-M. BATHROOM -PAGE: A MATERIAL: SCH40 HWC: 120 ' Diameter .{ Equivalent Fitting Lengths in Feet (in). E T. L C B G A D t, Ell Tee 1.049 '2..00 5.00 2.00 5.00 6.00 1.00 1.0.0 1.00 ` ` �• " PAGE: H '' 4MATERIAL: CPVC HWC: 150 ,' n' Y' Diameter Equivalent. Fitting Lengths -in Feet (in) E T R 'K C L B ., L El -1 Tee TEERUN COUPLG EL45 ;1.101 7:00 5:00 1.00 .0.'00 1.00 1.00 0.00 1.00 `• r _ PAGE: I' MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet r •(in) E T L C B G A• D r •' Ell Tee + 1.025, 3.00- 8.00 2.00 8.00 2.00 2.00 0.00 -0.00 -1.265 a, 5.00 9.00 2.00 11.00 2.00 2.00 0.00. 0.00 :PAGE:_J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet •(in) E T L C B G A. D Ell Tee .. 1.5906.00 12.00 3.00 14.00 .8:00 2.00• 0.00 0'.00''. PAGE K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee L r 0.995 2.00 6.00 1.50 0.00 0.00 3:00` 0.00 0.00 is , • _ n ♦ - - • Vit. - i •. ` ' SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page .5" r DATE: 11/4/2011. C:\HASS74\d4663:SDF -JOB TITLE: LAWSON RESIDENCE ONE HEAD CALC-M. BATHROOM WATER SUPPLY ANALYSIS Static: 81.00 psi Resid: 75.60 psi Flow: 500.0 gpm ES -F 825Y SPEC IFICATION SHEET , yx.7�jnBCO Series 825Y Reduced Pressure Zone Assemblies Size: 3/4" - 2" (20mm - 50mm) The FEBCO Series 825Y Reduced Pressure Zone Assemblies are used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. They are also used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. Features • Ultimate mechanical protection of potable water, against hazards of cross -connection contamination. • Meets all specifications of AWWA, ASSE, CSA and approved by the Foundation for Cross-Gonnection Control and Hydraulic Research at the University of Southern California. • Flow curve generated by the Foundation of Cross -Connection Control and Hydraulic Research at the University of Southern California. • Modular relief valve for ease of maintenance. • Simple Service procedures" All intemal parts serviceable in line. • Low head loss. • Spring loaded 'Y' type check valves. • Intemal relief valve pressure sensing passages. • Replaceable seat rings on all sizes. • End connection — NPT ANSI / ASME 81.20.1 Specifications The reduced pressure zone assembly shall consist of two independently operating, spring loaded, 'Y' pattern check valves and one hydraulically dependent differential relief valve. The assembly shall automatically reduce the pressure in the 'zone' between the check valves to at least 5psi lower than inlet pressure. Should the differential between the upstream and the zone of the unit drop to 2psi, the differential relief valve shall open and main- tain the proper differential. Mainline valve body and caps including relief valve body and cover shall be bronze. Check valve moving member shall be center stem guided. All hydraulic sensing passages shall be internally located within the mainline and relief valve bodies and relief valve cover. Diaphragm to seat area ratio shall be 10:1 minimum. Relief valve shall have a removable seat ring. Check valve and relief valve components shall be constructed so they may be serviced without removing the valve body from the line. All seat discs shall be revers- ible. Shutoff valves and test cocks shall be full ported ball valves. The assembly shall be rated to 175psi (12.1 bar) working pressure and water temperature range from 320F to 140"F (O°C - 600C). The assembly shall meet the requirements of ASSE Standard 1013; AWWA Standard Code C511; CSA Standard 864.4; and approved by the Foundation for Cross -Connection Control and Hydraulic Hydraulic Research at the University of Southern California. Job Name Job Location Engineer Approval Operation In a flow condition the check valves are open with the pressure between the checks, called the zone, being maintained at least 5.Opsi lower than the inlet pressure and the relief valve is maintained dosed. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi lower than the supply. When normal flow resumes, the zone's differential pressure will resume and the relief valve will close. Typical Installation Reduced pressure zone assemblies should be installed with minimum clearance of 12' (300mm) between relief valve discharge port and floor or grade. They must be installed where discharge will not be objectionable and can be positively drained away. They should be installed where eas- ily accessible for testing and maintenance and must be protected from freezing. Thermal water expansion and/or water hammer downstream of the backflow preventer can cause excessive pressure. Excessive pressure situations should be eliminated to avoid possible damage to the system and assembly. Refer to local codes for speck installation requirements. Some codes may prohibit vertical installation. 30" Max. (700mm) 12" Min. (300mm) No Flow Contractor Approval Contractor's P.O. No. Representative FEBCO productspecifications in U.S. customary unite and metric are approximate and are provided for reference only, For precise mea= surements, please contact FESCA, FESCA reserves the right to change or modify produet design# constrHetlen, 8p®61floofl®ns, Of M81SHO li Capacity Temperature — Pressure - Maximum working pressure: 175psi (12.1 bar) 138 �' '/a" (20mm) Hydrostatic test pressure: 350psi (24.1 bar) " 1, " 0 103 15 Temperature range: 32°F to 140"F (0°C to 60°C) ,o Materials r , 34 5 0 5 10 15 20 25 30 gpm Main valve body: Bronze 0 19 38 57 76 95 114 ram Relief valve body: Bronze f 5 75 10 15 fps 15 23 3.1 4.6 mps Elastomers: Nitrile Seat Discs kPa psi ' 1" (25mm) 1 Diaphragms: Nitrile, fabric reinforced 13e 20 Springs: Stainless Steel ' t00 15 Approvals 'Standards m 10 • Approved by the Foundation for Cross -Connection Control and 34 5 ]I]- Hydraulic Research at the University of Southern California. 010 20 30 4o 50 60 gpm 0 38 76 114 151 190227 Ipm • AWWA C511 Conformance t 5' 75 10 15 20 fps 1 • o.. ^ 15 23 3.1 45 6.1 , mps a kPa PSi 1'h" (40mm) A ® U PC 138 ?D O � � r • -. 103 15 1013 864.4 _ 69 10 34 5 0 - 211 60 80 100 120 gpm r 0 76 - 151 227 304 379 450 Ipm 5 75 10 15 fps { " 15 23 3.1 4.6 mps a '; .. Id'a psi r 2" (50mm) - 138 20 0 103 15 - ' s 69 10 5 0 40 80 120 160 200 240 gpm f 0 151 304 454 606 760 910 Ipm •' 5 7.5 10 15 20 fps 15 23 11 4b 6.1 mps Side View - ---------------- A----------- B` .Dimensions -Weights - ' •--------� � --- ~ Size: %" - 2" (20 - 50mm) IGHT�.r' SiZCt(DN) r�MENS�ONS 3r e ti.: fie.,•nrc�k., �x...*�;' �.✓ s r,F•s.._...-rn.. a'4°s.`.c M.�A.t: ,.�, ,,vv,,,x.�yc0.. - C , " A B. C D' E - iin. mm in. mm In. I mm in. I mm in, mm in. mm lbs. kgs. 3Y4 20 12 305 73Y4 197. 3'/a 833'/a 1 83 1 41A 11051 11.51 5.2 p 1 25 123/4 324 73/4 197' 31/a 83 31/a 83 41% 105 12.5 5.7 w. 114 - 40 -17 432 1OIA 267 444 114 41h 114 5 127 26,5T1 2.0 ` 2 50 17�i 451 1 101A 267 4)F 114 41h 1114 1 5 1127 129.0113.0 a Top View * B Dimension is less shutoffs' Note: Weights shown are approximate. Dimensions shown are nominal,` ' allowance must be made for normal manufacturing tolerances. E FEBCO •9001-2000 ® CERTIFIED " A Watts Water Technologies Company USA 4381 N. Brawley • Ste.102 • Fresno, CA • 93722 • Tel. (559) 441-5300 • Fax: (559) 441-5301 • www.FEBCOonline.cam Canada: 5435 North SeMce Rd. • Burlington, ONT. • L7L 5H7 • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.FEBCOonline.ca Bulletin 006Rev. F Model RFC30 (SIN RA0611) °afj,,t y , c° M d 1 RFC43 SIN RA0612 3{` . p Model RFC49 (SIN RA0616) o lei Ja 33' Residential Flat Concealed "' 33 r • , E Sprinklers , '; `iy • ` .�{ A Residential Flat,Concealed �'. S rinklerengineered fora minimum� q ♦ J 3 - ry . design density of 0.05 gpnVW with ♦ low GPM requirements.,,zk� ••( JGk.yi/Gr, . . • ♦ _ F Y Features ° ' . . M• .: » � , r.. 3 t u ;dL;3g 1.: Very low water flow requirements. r E; { 2.'/2"-(13mm) Total adjustment: Thread -On Thread -Off or Push-On%Thread Off cove tion:- r attachment option; ` r `` 4. Smooth aesthetic ceiling profile. " • - - ' �s- 5. Available in bra's§, chrome and black plated , 7 n �• or -painted finishes. v • i� r !•' ,` J • - ♦ . • J . t i " 'Listings & Approval , PP r -� ~} I. Listed by Underwriters Laboratories, and .' f=' certified by UL for Canada (cULus)„ {+; 2. NYC MEA 258-93-E UL Listing Categories . 14"W J y Residential Automatic Sprinklers UL Guide. Number Product . Descri tion I :Model RFC30, RFC43 and RFC49 Concealed Residen- the most dependable fire protection available, an automat ' tial Sprinklers are fast response residential fusible solder is sprinkler system. , link automatic sprinklers. Residential sprinklers differ from The RFC30, RFC43 and RFC49 are UL Listed Residential • _ standard sprinklers primarily in their response time and Sprinklers to be installed-in'the residential portions.of any water distribution patterns. occupancy in accordance -with NFPA 13,13R, & 13D. , Model RFC30, RFC43 and RFC49 sprinklers discharge The RFC30, RFC43 and RFC49 can reduce the need for I water, in a hemispherical pattern below the sprinkler de ' precise cutting of drop Hippies. E The threaded cover plate .a fflectbr. Residential distribution patterns are higher and assembly can be•adjusted without tools to fit accurately generally contain a finer droplet size than standard sprin- ' against the. ceiling. The fire protection system need not be kler patterns. - ,shut down to a. djust or remove the cover -plate assembly. 1. The combination of speed of operation and high dis-* ,. • ' ' , Application and Installation ' ' charge pattern required for residential sprinklers has•dem- s , Y The RFC30, RFC43 and RFC49, for residential installa- I . anstrated, in fire testing, an ability for controlling residen- tions, tions, use a 165°F (740C) fusible solder link in a tuning fork tial fires, and thereby providing significant evacuation time `. style sprinkler frame with a drop-down deflector. '-This as-' ,. for occupants. .� ..I The RFC30; RFC43 and RFC49 Sprinklers provide the sembly is recessed into the ceiling and concealed by a flat best form of fire protection by combining an attractive ap- ' cover plate. The cover plate is attached to the skirt, using , ' pearance and'/i",(13rrim) of cover adjustment for ease of 1350F (57°C) ordinary temperature, classification', solder. - installation.' The small diameter cover plate is easily. and When the ceiling temperature ,rises, the solder,_ holding._ .. positively attached and blends into the ceiling, concealing -the cover plate releases the cover allowing the deflector the inside to drop into position and ,exposing sprinkler to,��f 4 r y ° The. Reliable Automatic. Sprinkler: Co", Inc..; 1:03 Fairview Park. Drive, Elmsford, New.. York 1.0523 ceiling temperature. The subsequent operation of the sol- der link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distri- bution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2% inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART Temperature Rating OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Note: A leak tight 1/2" NPT (R1/2) sprinkler joint can be ob- tained with a torque of 8-18 ft -lbs (10,8 - 24,4 N -m): Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Cover assemblies provide up to 'h" (13mm) of adjust- ment. Turn the cover clockwise until the flange is in con- tact with the ceiling. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final adjust- ment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover removal requires turning in the counter. -clockwise direction. In ceilings that have a plenum space above the. sprinkler, the plenum space may have neutral or negative pressur- ization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Sprinkler Cover Plate Max. Ambient Temp. 165°Fl74°C 135°F/57°C 100°F/38°C Installation Data: RFC30 (SIN.RA0611) Thread Size inch (mm) K Factor Sprinkler Spacing ft, (m) Maximum Distance to Wall ft. (m) Minimum Distance between sprinklers ft. (m) Minimum Required Sprinkler Discharge Flow gpm (Lpm) Press. psi (bar) , 'h" (15mm) 'h" (15mm) 3.0 3.0 12 x 12 (3.6x3.6) 14 x 14 (4.3x4.3) 6(1.83) 7(2.13) 8(2.43) 8(2.43) 9(34.1) 10 (37.8) 9.0 (0.62) 11 (0.76) Note: 1 bar = 100 Kpa Installation Data: RFC43 (SIN RA0612) Thread Size Inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum Distance to Wall Minimum Distance between sprinklers Minimum Required Sprinkler Discharge Flow Press. ft: (m} ft: (m) gpm (Lpm) psi (bar) h" (15mm) 4.3 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 12 (45) 7.8 (0.54) 'h" (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 9.1 (0.63) 'h" (15mm) 4.3 16 x 16 (4.9x4.9) 8 (2:43) 8(2.43) 13 (49) 9:1 (0.63) 'h" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18 (68) 17.5 (1.21) 'h" (15mm) 4.3 20 x 20 (6.0x6.0) 10 (3.05) 8 (2.43) 21 (79) 23.8(l.64) Note: 1 bar = 100 Kpa Installation Data: RFC49 (RA0616) Thread Size Inch (mm) K Factor Sprinkler Spacinngg ft• (m) Maximum Distance to Wall Minimum Distance between sprinklers Minimum Required Sprinkler Discharge Flow Press. ft. (m) ft. (m) gpm (Lpm) psi (bar) 4.9 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 13 (49) 7.0 (0.48) 'h'(15mm) 4.9 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 7.0 (0.48) 'h' (15mm) 4.9 16 x 16 (4.9x4.9) 8(2.43) 8(2.43) 13 (49) 7.0 (0.48) 'h" (15mm) 4.9 18 x 18 (5.5x5.5) 9 (2.74). 8 (2.43). 17 (64.3): 12.0 (0.83) 'h" (15mm) 1 4.9 20 x 20 (6.04.0) 10 (3.05)' 8(2.43) 20 (75.7) 16.7(l.14) Note: 1 bar =100 Kpa IFORSLOPED CEILING APPLICATIONS SEE RASCO BULLETIN -036 I 2. Y Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler cover plate assem- bly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used. to minimize the potential. for damage to. sprinklers that would cause improper operation or non -operation. Model RFC30, RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential con- cealed sprinklers with drop-down deflector and adjust- able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a %2" NPT thread. Thermal element shall consist of an approved black -painted beryllium -nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon -coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K -factor shall be nominal 3.0 (44), 4.3 (62.4), and 4.91 (70) having a5/16", 3/8' and 7/,s' orifice. Temperature rating shall be Ordinary 165°F (74°C); cover plate temperature rating to -be 1350F (570C). Cover plate assembly shall 1-x 1/2- REDUCING TEE OR ELBOW 2J' (58.42-m] DIA CEILING ' [12.70mm] MAX j� COVER ADJUSTMENT / I CCP COVER PLATE ASSEMBLY consist of a brass cover plate and copper alloy retainer flange allowing a 1/2" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and -factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from dam- age, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty — specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 (Bulletin 006), Model RFC43, SIN RA06.12 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). Ordering Information Cover Plate Finishes ( ) Specify: Standard Finishes 1. Sprinkler Model 2. Cover Plate Finish chrome Fite 3. Thread -On or Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome Push -On Feature 2' (50.8mml MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION COVER PLATE 112" (12.7mm ADJUSTMENT 3. 006FW FA (1) Other colors and finishes avail- able. Consult factory for details. Note... Paint or any other coatings applied over the factory finish will void all approvals and warran- ties. 0Reliable.1111I.For Com iete Proiec. Reliable offers a wide selection of'sprinkler components. Following are some. of the many precision -made Reliable products that guard life and property from fire around the clock. e Automatic sprinklers . Deluge.valves ..Flush automatic sprinklers • Detector, check valves • Recessed automatic sprinklers • Check valves • Con.oeajed. automatic sprinklers Electrical system w • Adjustable. automatic sprinklers • Sprinkler emergency cabinets Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers. • Sprinkler escutcheons and guards • Open sprinklers Inspectors test connections •Sp ray nozzles • Sight drains • Alarm valves • Ball drips and. drum drips, • Retarding chambers *'Control valve seals .Dry pipe valves •Air maintenance devices •. Accelerators fo(dry pipe valves • Air compressors • Mechanical sprinkler alarms Pressure gauges Identification signs • Electrical sprinkler alarm switches • Fire department connection • Water flow detectors The ecluipment.presented..-this .bulletin:is to be installed:iri accordance with..the Iatest.published..StandTo$ of�the National.: ire Protection..A$spciation. Factory. Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsrnanufactured and distributed by Reliable have been protecting Irfe and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled ®... Paper (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesDrinkler.com Internet Address EG. Printed inU.s.A 02/11, PM 999997o261 Bulletin 135 Rev. H m Model F1 Residential Spriniders for Design Density of .05 gpmfft2 CD Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm/ft2- Types: y y 1. F1 Res 30 Pendent �: •��,e - . z . ,,. - .. 2. F1 Res 30 Recessed Pendent/F2 3. F1 Res 30 Recessed Pendent/FP F1 Res 30, 49, 58 & 76 F1 Res 30, 49, 58 & 76- 4. F1 Res 49 Pendent Recessed Pendent/ F1 Recessed Pendent / FP 5. F1 Res 49 Recessed Pendent/F1 6. F1 Res 49 Recessed Pendent/FP 7. F1 Res 58 Pendent 8. F1 Res 58 Recessed Pendent/F1 9. F1 Res 58 Recessed Pendent/FP 10. F1 Res 76 Pendent 11. F1 Res 76 Recessed Pendent/F1 12. F1 Res 76 Recessed Pendent/FP 13. F1 Res 30 CCP Pendent 14. F1 Res 49 CCP Pendent 15. F1 Res 58 CCP Pendent 16. F1 Res 76 CCP Pendent 17. F1 Res 44 HSW 18. F1 Res 44 Recessed HSW/F2 19. F1 Res 58 HSW 20. F1 Res 58 HSW Recessed HSW/F2 21. F1 Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E Slope Ceiling Approvals: Refer to Bulletin 035 Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers Product Description Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass -bulb and low profile decorative de- sign. The F1 Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attractive when above ceiling piping can- not be used. yak{ F1 Res 30, 49, 58 & 76 F1 Res 44 & 58 CCP Pendent Recessed HSW/F2 The 3mm glass -bulb pendent sprinklers permit the effi- cient use of residential water supplies for sprinkler cover- age in residential fire protection design. The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protec- tion application needs of the latest residential market stan- dards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat -sensitive glass -bulb to shat- ter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass -bulb • Sprinkler Frame : Brass Casting • Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: Y2" NPT (RI/2) • K -Factor: 3.0 (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (Actual) - F1 Res 58 Pendent & HSW Sprinkler 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.05 gpm/ft2 The Reliable Automatic Sprinkler Co., Inc., .103 Fairview Park Drive, Elmsford, New York 10523 Application Installation Model F1 Res Sprinklers are used for Residential Fire Pro Models F1 _Res sprinklers are to be installed as"shown: tection according to UL 1.626 Standard'. Be sure that ori- Model F1, 'F2 and FP Escutcheons, illustrated herewith; fice size, temperature rating, deflector style and"sprinkler are the only recessed escutcheons to be used with Model type are in accordance with the"latest published standards: F1 Res sprinklers. Use of any other recessed escutcheon, of The National Fire Protection Association or the approving will void all approvals and warranties. For installing Model authority having jurisdiction. F1 Res Pendent sprinklers.use only the Model 0 sprinkler • Model F1. Res 30 Recessed Pendent/ F2 r F1 escutcheon. 3/4" (19mm) adiiustment Fig. 1 Fig. 2 Wrench; for installing Models F1 Res Recessed Pendent, Escutcheon*, F1 or F2, Data: CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 Res Recessed HSW sprin- klers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 with a ceiling to deflector dis- tance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Adjustment :.A„ Face of fitting Type Inch (mm) Inch (mm) toceiling F1 3/4(19.0) Min.=3/4" (19.1) Max.=1'/2" (38.1) (4.7-24.0) F2 1/2(12.7) Min.=s/s" (23.8) 1%_ "h6 Max.=1'/z" (38.1) (4.7 -17.4) Thread Nominal Orifice Sprinkler Max. Max. Actual Sprinkler ' Size Inch (mm) Temp. Rating Pressure Ambient Temp. K Length - °F °C OF °C 4.9 2.25 (57) psi bar + . Factor Inch mm 'h" NPT R/z zi/,- (8.2) 155 . 175 68 79 175 (12) 100 38 3.0 2.25 (57)' ' Deflector - to - ceiling t. Maximum 1" (25mm) to 4" (100mm) . Max' Nominal Orifice Inch (mm). Sprinkler Temp. in Max.. Pressure psi bar I ' Sprinkder Spacing Flow Pressure Sprinkler Identification ft m. gpm (Lpm) psi (bar) Number (SIN) m412 x 12 (3,6 x 3,6 8 30.3 7.0(0,48) R3511 14 x 14 4,3 x ,3 10 37.8 11 0,76 ` Technical Data: F1 Res 49 Pendent and Recessed Pendent. y Thread ' Size' Nominal Orifice Inch (mm). Sprinkler Temp. in Max.. Pressure psi bar Max. Ambient Temp. Actual K Factor • Sprinkler ` Length Inch mm OF I °C OF I °C 'fa" NPT (R 1/2) • 7/, fi (11) 155 175 68 79 175 (12) 100 150 38 66 4.9 2.25 (57) Deflector - to - ceiling Deflector - to,- ceiling F Maximum 1" (25mm) to 4" (100mm) Maximum 4" (100mm) to 8" (203mm) +_ Max. Flow Pressure gpm (Lpm) psi (bar) Sprinkler' - Iderrtification Number (SIN) ' Sprinkler Flow Pressure Sixinkler Identification , R3516,,'., } - Spacing gpm (Lpm) psi (bar) ft� m 12 x 12 (3,6 x 3,6) 13 (49) . 7.0 0,48 NumberSIN Number() 16 x 16 4,9 x 4,9 17(64.3) 12.00.83 - t 14 z 14 (4,3 x 4,3). 13 49) 7.0 0,48 " 16 x 16 (4,9 x 4,9) 13 49 7�0,83 83516 •20x20(6,1 x 6,1) 18 x 18 5,5 x 5,5 17 64.3 120 Number (SIN) °C x 20 6,1 x 6,1 20 75.7 16.7 1,14 °C Max. Sprinkler 4 Spacing ft m Flow Pressure gpm (Lpm) psi (bar) Sprinkler' - Iderrtification Number (SIN) 12 x 12 (3,6 x 3,6) 15 57 9.4 0,65 , R3516,,'., 14 x 14 4,3 x 4,3) 16(60.5) 1 10.6 0,73 16 x 16 4,9 x 4,9 17(64.3) 12.00.83 18 x 18 5,5 x 5,5 5.0 1,0 19 72 15.0(1 •20x20(6,1 x 6,1) 22(83-21 202 1,4 . ` • + • 'Note: The F1 Res 49 pendent and,recessed pendent residential sprin- klers can be installed per NFPA 13 in beamed ceilings meeting f the following criteria: «f 1. Maximum beam depth = 7- (178mm) _ 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center... ,Technical Data: F1 Res 58 Pendent and Recessed Pendent. Thread Nominal Orifice Sprinkler Max. Max Actual 'Sprinkler Size Inch. Inch(mm) (mm) T Ratin Pressure Ambient Temp. K Factor Length. Number (SIN) °C OF °C psi bar 16 61 Inch mm . Yz" NPT 'h'(1 3) 155 68 175 (12) 100 38 5.8 225 (57) R'/z 20 x 20 6,1 x 6,1 22 83.3 14.4 1,0 175 79 150 66 3. Sprinkler Flow Pressure Ceiling -to- Deflector Sprinkler Identification Spacing gpm (Lpm) psi (bar) Inch (mm) Number (SIN) ft m 12 x 12 3,6 x 3,6 16 61 7.6 0,53 1- 4 (25- 100) R3513 14 x 14 4,3 x 4;3 16 61 7.6 0,53 16 x 16 4,9 z 4,9) 16 61 7.6 0,53 18 x 18 5,5 x 5,5 19 72 10:8 0,75 20 x 20 6,1 x 6,1 22 83.3 14.4 1,0 3. Technical Data: F1 Res 76.Pendent and Recessed Pendent Thread Nominal Orifice Sprinlder Max. Max." K Sprinkler Size Inch (mm) Temp. Ratin Pressure. Ambient Temp. Factor Length OF °C OF °C psi bar Inch mm 3/4" NPT -.155 17W (13.5) 68 . 175(12). 100 7.6 2.25 (57) R'/2 175 79 150 gg " Max. Sprinkler Spacing ft(m Flow gPm (LPm) Pressure psi (bar) Sprinkler Identification Number (SIN) ' 12 x 12 3;6 x 3,6 21 79.5 7.6 0,53 R7618 14.x 14 (4,3 x 4,3) 21 79.5 7.6 0,53) 16 x 16 (4,9 x 4,9 21 79.5 7.6 (0,53 ' 18 x 18(6,5 x 5,5 21 79.5 7.6 0,53 20 x 20 6,1 x 6,1 23 87.1 9.2 (0,63 • Model F1 Res 30, 49, 58 & 76 CCP Pendent Model F1 Res 30, 49, 58 & 76 Recessed Pendent/ FP FP push-oNthreao-off escutcheon Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/FP • - Thread Nominal Sprinkler CCP Assembly Max. -Max. K Sprinkler Size Orifice Temp. Ratin Tem . RatingPressure Pressure Ambient Tem Factor Length ,t °F °C °F °C ' °F °C °C Inch mm si bar 14 x 14 4,3 x 4,3) 1 11 41.6 13.4 (0,92) - Inch mm '/z" NPT (R 112) (8.i) 155 68 135 57 175 (12) 100 38 3.0 2.25 (57) Thread Max. Flow, pressure Sprinkler Identification Max. Max: ' Sprinkler Spacing gPm (Lpm) psi (bar) Number Orifice Temp. RatingTemD. Ratin Pressure ft m SI Length + °C OF 12 x 12 3,6 x 3,6) 8 30.3 7.0(0,48) OF °C ,4.. Inch mm 14 x 14 4,3 x 4,3) 1 11 41.6 13.4 (0,92) - R3511 Inch mm 'h" NPT (R 1/2) Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP 155 68 135 57 175 (12) Nominal Sprinkler Assembly 5.8 Max' Sprinkler CCP Options Data: 66 Thread Orifice Temp. Temp. MCP a x. ur Presse Ambient K Length "A" "B" Size Inch Rating Ratingpsi (bar) Temp. Factor ' Inch Cover Adjustment CCP Height • mm ( ) °F °C °F °C °F °c (mm). Inch mm Inch mm '/z" NPT 12.7) ahs 24 ' ~ (R 112) ,/16" (11) 155 68 135 57 175 (12) 100 38 4.9 2.25 (57) Sz hs (7.9 /. 19) , Max. Sprinkler FP Data • W% , Sprinkler Spacing Flow Pressure Identification "A" ` ft m gpm (Lpm) psi (bar) Number (SIN)- FP Position Inch mm 12 x 12 3,6 x 3,6) 13(49) 7.0 0,48 Max. Recessed '/ s(11). 14 x 14 4,3 x 4,3 13 (49) 7.0 0,48 Min. Recessed 15116 24 16 x 16 (4,9 x 4,9) 14 53 8.2 0,56 83516 Note: Sprinklers shown in Fig. 3 and Fig. 4 18 x 18 5,5 x 5,5 18 68.1 13.5 0,93 are not Suitable for installation in ceil- 20x20 6,1x6,1) 20 75.7 16.7(1,14) ings which have positive pressure in the space above. . Technical Data: F1 Res 58 CCP Pendent and Recessed PendenVFP Thread Nominal • Sprinkler CCP Assembly Max. Max: K Sprinkler Sue Orifice Temp. RatingTemD. Ratin Pressure Ambient Tem Factor Length OF °C OF °C OF °C psi bar Inch mm I bar "/3z" (13.5) Inch mm 'h" NPT (R 1/2) '/i' (13) 155 68 135 57 175 (12) 100 38 5.8 2.25 (57) Max Sprinkler Spacing ft m Flow m (L 9Ppm) Pressure Psi (bar) Sprinkler Identification Number Sl 12 x 12 3,6 x-3,6) 16 61 7.6 0,53 R3513 14 x 14 4,3 x 4,3 16(61). 7.6(0,53) 16 x 16 4,9 x 4,9 16(61) 7.6(0,53) 18 x 18 5,5 x 5,5) 19 72 10.8 0,75 20 x 20 6,1 x 6,1 22 83.3 14.4(1,(l Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP 3 Thread Nominal Sprinkler Max. Sprinkler Spacing ft(m) Flow 9Pm (I -Pm) CCP Assembly Max. Max. K � Sprinkler Size Orifice Temp. Ratting . TemD. Ratin Pressure Ambient Temp._ Length Factor OF °C OF °C OF °C. Inch mm psi bar Inch mm 3/4'NPT . "/3z" (13.5) 155 68 135 57 175 (12) 100 38 7.6 2.25 (57) R3/4 175 79 150 66 Max. Sprinkler Spacing ft(m) Flow 9Pm (I -Pm) Pressure Psi (bar) Sprinkler Identification Number , 12 x 12 3,6 x 3,6 21 79.5 7.6 (0,53 R7618 .14 x 14 (4,3 x 4,3) 21 79.5 7.6 0,53 16 x 16 4,9 x 4,9 21(79.5) 7.6 0,53 18 x18 j5,5 x 5,5) 22 83.3 8.4 0,58 20 x 20 6,1 x 6,1 25(94.6) 10.8 0,74 5. r • , i.� . - ' . . .. ♦ 1 ..fid w " Fig. 5 Sprinider Temp. Rating (, OFC) y Max Sprinlder. IdeiMication Number (SIN) J 2 x 12 3,6 x 3,6 , 4-6 (101-152) ii 155 68 175 79 Face of Fitting Thread Nominal Orifice' Sprinlder Temp. Rating .Max. Pressure Ambient K.. Sprinlder Length Type Adjustment ,inch (mm) i to wail Size Inch (mm)F 12 x 12 3,6 x 3,6) .. psi (bar) Tem P. , Factor Inch (mm) _ . , 14 x 14 4,3 x 4,3 Inch (mm) "16x 16.4,9 x 4,9 •C ,F 'C 16 x 20 4,9 x 6,1 155 (68)' 175 (79 23' 87,1 27,4 11,89 t 4 F2 escutcheon, 1/2" (13mm) adjustment ahs- 'h Rfz 3/e' (10) ,~' ` 68 79 ;+R' -Technical Data: F1 Res 44 HSW & HSW/F2 F • h" 38 1 66 i j` �w •- Escutcheon; F2, Data: • f (4.7 - 17.4) , " Ceiling to Deflector Inch mm Sprinider Temp. Rating (, OFC) Flow 9 P (Lpm) • Max Sprinlder. IdeiMication Number (SIN) J 2 x 12 3,6 x 3,6 , 4-6 (101-152) ii 155 68 175 79 Face of Fitting Thread Nominal Orifice' Sprinlder Temp. Rating .Max. Pressure Ambient K.. Sprinlder Length Type Adjustment ,inch (mm) i to wail Size Inch (mm)F 12 x 12 3,6 x 3,6) .. psi (bar) Tem P. , Factor Inch (mm) _ . , 14 x 14 4,3 x 4,3 Inch (mm) "16x 16.4,9 x 4,9 •C ,F 'C 16 x 20 4,9 x 6,1 155 (68)' 175 (79 23' 87,1 27,4 11,89 "/s', 4 ahs- 'h Rfz 3/e' (10) 175 ` 68 79 175(12). 1' 150 38 1 66 , 4.4 2.45 (62) F2 '/,(13) f (4.7 - 17.4) , Max...A„ .` Sprinlder Spacing' (m) Ceiling to Deflector Inch mm Sprinider Temp. Rating (, OFC) Flow 9 P (Lpm) • Pressure Psi (bar) Sprinlder. IdeiMication Number (SIN) J 2 x 12 3,6 x 3,6 , 4-6 (101-152) ii 155 68 175 79 12 45,4 7.5 0,52 R3531 14 x 14 4,3 x4,3 155(68) 175(79) 14 53,0 10.2 0,71 16 x 16 4,9 x 4,9 155 68 175 79 16 60,6) 13.3 (0,92)' 16 x 18 4,9 x 5,5 155 68 175 79 18 68,1 16.8 1,16 18 x 18 5,5 x 5,5 155 68 175 79 19 72,0 18.7 1,29 16 x 20 4,9 x 6,1 155(68) 175 79 23 87,1 27.4 1,89 12 x 12 3,6 x 3,6) .. ` 6=12 (152 - 305) 155(68), 175 79 14 53,0) 10.2 0,71 _ . , 14 x 14 4,3 x 4,3 1,75 79 16 60,6 13.3 0,92 155Z68 "16x 16.4,9 x 4,9 155175 79 17 64,4 15.0 1,04 16 x 18 4,9 x 5,5) 155 68 175 79 20 75,7 20.7 1,43 16 x 20 4,9 x 6,1 155 (68)' 175 (79 23' 87,1 27,4 11,89 Technical Data: F1 Res 58 HSW & HSW/F2 a Thread Nominal Sprinkler Max. Max. Ambient K Sprinkler Size Orifice Temp. Rating Pressure Tem O Factor Length 16 x 16 4,9 x 4,9 Inch (mm) psi (bar) 155(68) 175(79), 25 (94,7 18.6 1,28 Inch (mm) °F °C F oC 22 83,3 14.4 1,0 14 x 14 4,3 x 4,3 155 68 175 79 22 83,3 14.4 1,0 '/z" NPT RYz V (13) 155 175 68 79 175 (12) 100 150 38 66 5.8 2.45 (62) Escutcheon, F2, Data: Max Sprinkler Spacing ft m "A" Ceiling to Deflector Inch mm Face ofFitting T Type Adjustment Inch (mm) ll 12 x 12 3,6 x 3,6 (101 - 52) Inch (mm) F2 '/2 (13) 3/16 - 11/16 (4.7-17.4) Max Sprinkler Spacing ft m "A" Ceiling to Deflector Inch mm Sprinkler Temp. Rating OF °C Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number SIN 12 x 12 3,6 x 3,6 (101 - 52) 155(68) 175 79 16(60,6) 7.6 0,53 . R3533 , 14 x 14 4,3 x 4,3 155 (68 175 79 18 68,2 9.7(0,67) 16 x 16 4,9 x 4,9 155(68) 175 79 21 79,5 13.2 0,91 16 x 18 4,9 x 5,5 155(68) 175(79), 25 (94,7 18.6 1,28 16 x 20 4,9 x 6,1 155(68) 175 79 29 109,8 25(1,73) 12 x 12 3,6 x 3,6 6-12 (152-305) 1 155(68) 175(79) 22 83,3 14.4 1,0 14 x 14 4,3 x 4,3 155 68 175 79 22 83,3 14.4 1,0 16 x 16 4,9 x 4,9 155 68 175 79 26 98,4 20.1 (1,39 16 x 18 4,9 x 5,5 155 68 175 79 31 117,4 28.6 1,97 i' • Model F1 Res 44 SWC i Pennicai uatae Fi RPs as -qwc i Fig. 6 Thread Nominal Cover Sprinkler. Temp. Max. Max. Ambient a' io 12" Sprinkler Size [101.To• Temp. Rating R na Pressure 30,60- sa- ]. I I/!� (JI.73mm] LL°,dmum Length F O/ Mtinp psi (bar) PU6H ON LOVER. MEN T° W.11 Oim -;_ OF TURN rO ADWST U47k °C °F °C RIGHT AbVNST WALL.. I' X 1/2' Reducer L 1/2"NPT '/s" (10) 155 68 135 57 175 (12) 100 Recommemled 4.4 2.45(62) 18 68,1 16.8 1,16 16 x 18 4,9 x 55 20 75,6 20.7 1,43 W°° N°le 2 57(m/16'5,M'(58m] -}.-_ 1 5 --�- J 5/16' . Tl/IdV COLLAR UN70. RGHT A4'NNST WVW XLER WRENCH BOSS. lypppT 121/J2' [42.07--].. . I/1� [12.7pmn] Adlu5fmm7 F1 RES 44 SWC i Fig. 6 Thread Nominal Cover Sprinkler. Temp. Max. Max. Ambient K Sprinkler Size Orifice Temp. Rating R na Pressure Tem . Factor Length Inch (mm) psi (bar) (101- 152) Inch (mm) OF °C OF °C °F °C 16 x 18 4,9'x 5,5 19 71,8 18.7(1,13) 1/2"NPT '/s" (10) 155 68 135 57 175 (12) 100 38 4.4 2.45(62) Max. «A, Sprinkler Sprinkler Spacing Ceiling to g Flow Pressure Identification ft (m) Deflector gpm (Lpm) psi (bar) Number (SIN) Inch mm 12 x 12 3,6 x 3,6 (101- 152) 13 49,2 . 8.7 0,60 14 x 14 4,3 x 4,3 14 53,0 10.2 0,71 16 x 16 4,9 x 4,9) 17 64,3 15.0 1,1 16 x 18 4,9'x 5,5 19 71,8 18.7(1,13) R3531 16' x 20 4,9 x 6,1 . 23 87,1 27.4 1,89 12 x 12 3,6 x 3,6 6 _ 12 (152-305) 14 52,9 10.2 0,71 14 x 14 4,3 x 4,3 15 56,7 11.7 0,81 16x16(4,9x4,9) 18 68,1 16.8 1,16 16 x 18 4,9 x 55 20 75,6 20.7 1,43 7. Maintenance Model F1 Res 30, 49, F1 Res 58, F1 Res 76 and F1 Res 44 be a steel, two-piece escutcheon [with Y2" adjustment (Model .; Sprinklers should be inspected quarterly, and the sprinkler sys- 172)] [with 3/a" adjustment (Model F1)] [of push -on and thread off , ;,J tem maintained in accordance with NFPA 25,13,13D, and 13R. design with 112" adjustment (Model FP)]. Standard finish shall be ' Do not clean sprinkler with soap and water, Ammonia or any oth- [brass][bright chrome] [white painted]. Residential recessed, • er cleaning fluids. Remove dust by using a soft brush or gentle • pendent sprinklers shall be Reliable [Model F1 Res 30, 49 & 58 • vacuuming. Remove any sprinkler which has been painted (oth- Recessed Pendent/F1] [Model F1 Res 30, 49 & 58 Recessed er than factory applied) or damaged in any way. A stock of spare Pendent/F2] [Model F1 Res 30,46 & 58 Recessed PendenVFP] , ' ', sprinklers should be maintained to allow quick replacement of SIN R3511, R3516 & R3513 (Bulletin 135)'. • ' • - - .. • f '•. - - 'damaged or operated sprinklers. Prior to installation, sprinklers ' Model F1 Res 30, 49 & 58 CCP pence (�!� Con should remain in the original cartons and packaging until used. Sprinklers shall be [cULus Listed] [New York City MEA 'Ap This will minimize the potential for damage to sprinklers that could proved (258-93-E)] low flow residential concealed sprinklers en - cause improper p per operation or non -operation. gineered to provide a minimum design density,of 0.05 gpm/ft2 Model F1 Res 30, 49 & 58 Pendent over the listed coverage area Listed flows as specified by the Sprinkler Specifications manufacturer's technical data sheets are to t5e used. Residential Sprinklers shall be [cULus Listed] [New York City MEA Ap- sprinklers shall be installed in conformance with the manufac- , =. _ proved (258-93-9] low flow residential pendent sprinklers en- turerrs installation guidelines and the applicable installation Stan gineered to provide a minimum design density of 0.05 gpm/ftz dard. Where pendent residential sprinklers are installed under' . -• -ti•5 „ ,{ over the'listed coverage area Listed flows as specified by the sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers manufacturer's technical data sheets are to be used. Residential be listed for such use. Sprinkler frame and deflector shall r" sprinklers shall be installed in conformance with the manufac : ,shall be of bronze frame construction having a'/z" NPT thread. Water • turer's installation guidelines and the applicable installation star seal assembly shall consist of a Teflon coated Belleville spring dard. Where pendent residential sprinklers are installed under . washer with topaoaded extruded or cold head'cup with 3 mm` • + sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers glass bulb containing no plastic parts, and having a temperature : shall be listed for such use. Deflector -to -ceiling distance listing `rating of 155°F (68°C). Cover plate assembly shall consist of a' shall be 1" to 8" maximum. Sprinkler frame and deflector shall brass cover plate and copper alloy retainer flange. Method of , • , ' be of bronze frame construction having a 1/2" NPT thread. Water ' attaching the cover plate to the sprinkler cup shall be a push- ., seal assembly shall consist of a Teflon -coated Belleville spring on and thread -off design allowing a Yi' cover plate adjustment.' washer with top -loaded extruded or cold head cup with 3 mm Cover plate temperature rating shall be 135°F (570C). A plastic _ "� • glass bulb containing no plastic parts, and having atemperature protective cap shall be provided and factory installed inside the. , rating of [155°F (680C)] [175°F (79°C)]. Sprinklers shall have a sprinkler cup to protect the sprinkler from damage, which cold nominal K -factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] occur during construction before the cover plate is installed. - OL ' „_• [Chrome -plated] [White Polyester) [Special finish- specify]. Resk Standard cover plate finish: rte Custom Color- specify]. dental pendent sprinklers shall be Reliable Model F1 Res 30,49 Concealed pendent sprinklers shall be Reliable Model F1 Res & 58, SIN R3511, R3516 & R3513 (Bulletin 135). 30,49 & 58 CCP, SIN 83511, 83516 &R3513 (Bulletin 135). Model F1 Res 49 & 58 Recessed 'PendenVF1, Model F1 Res 44 Horizontal SideWall Model F1 Res 30,49 & 58 Recessed Pendent/F2, Residential Sprinkler Specifications �_ ... ` Yr _, r Model F1 Res 30,49 & 58 Recessed PendenVFP Sprinklers shall be [cULus Listed],[New York City MEA Ap- - . Sprinklers shall be [cULus Listed] [New York City MEA•Ap- proved (258-93-E)] low flow residential horizontal sidewall sprin-.. i,'a proved (258-93-E)] low, flow residential recessed pendent Iders engineered to provide a minimum design,density of 0.05 < sprinklers engineered to provide a minimum design density ped gl�rW over the listed coverage area. listed flows as sped- of of 0.05 gpm/ft2 over the listed coverage area. Listed flows as fled by the manufacturer's technical data sheets are to be used. specified by the manufacturer's technical data sheets are to be Residential sprinklers shall be installed in conformance with the - used. Residential sprinklers shall be installed in conformance manufacturer's installation guidelines and the applicable instal - with the manufacturer's installation guidelines and the applica- lation standard. Where horizontal sidewall residential sprinklers ble installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to w are installed under sloped ceilings having a pitch from [4/12] [8/12], the sprinklers shall be listed for such use -'Sprinkler frame to [8/12], the sprinklers shall be listed for such use.. Deflector, and deflector shall be of bronze frame construction having a'/2". to -ceiling distance listing shall be 1" to 8" maximum. Sprinkler NPT thread. Water seal assembly shall consist of a Teflon -coat- frame and deflector shall be of bronze frame construction hav- ed Belleville spring washer with top -loaded extruded or cold ing a '/2" NPT thread. Water seal assembly shall consist of a head cup with 3 mm glass bulb containing no plastic parts, and Teflori-coated Belleville spring washer with top4oaded extruded having a temperature rating of [155°F (68°C)] [175°F (79°C)]. . ' or cold head cup with 3 mm glass bulb containing no plastic Sprinklers shall have a nominal K -factor of 4.4 (62.8). Standard parts, and having a temperature rating of [155OF(68°C)] [175°F finish: [Bronze] [Chrome -plated] [White Polyester] [Special fin- . (79°C)]. Sprinklers shall have a rwminal K -factor of 3.0, 4.9 & ish- specify] * Residential horizontal sidewall sprinklers shall be 5.8. Standard finish: [Bronze] [Chron,e plated] [White Polyester] Reliable Mo el F1 Res 44, SIN R3531 (Bulletin 135). # . [Special finish- specify]. Recessed escutcheon assembly shall y • S i` c. s Model F1 Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44/F2, SIN R3531 (Bulletin 135): Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum de- sign density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Sprinkler frame and deflector shall be of bronze frame construction having a3/4" NPT thread. Water seal assembly shall consist of a Teflon -coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a tempera- ture rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K -factor of 7.6. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special fin- ish— specify]. Residential pendent sprinklers shall be Reli- able Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a3/4" NPT thread. Water seal assembly shall consist of a Teflon -coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K -factor of 7,6. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjust- ment (Model F2)] [with 3/4" adjustment (Model F1)] [of push -on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/ F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Q Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable instal- lation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon -coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design h allowing a'" cover plate adjustment. Cover plate tem- perature rating shall be 135'F (57°C).iA plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Finishes t?> Standard Finishes Sprinkler F1, F2, FP Cover Plates Sprinkler Type Escutcheons Temperature Rating Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black Polyester White Painted Coated Special Application Finishes Sprinkler Cover Plates Escutr� ns Bright Brass Bright Brass Bright Brass Black Plated Black Plated Black Plated Black Paint Black Paint Black Paint Off White -Off White Off White Satin Chrome Satin Chrome Satin Chrome (') Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish Relia'ble..,'For- Corn ple'te'. Protect I o n _ . .. Reliable offers a wide selection of sprinkler components. Following are some of the many precision=made Reliable products that guard life and property from fire around the clock. w. • Automatic sprinklers !. Deluge•valves r . • Flush automatic sprinklers_ , • Detector check valves b • Recessed automatic'sprinklers Check valves ; • Concealed automatic' sprinklers' Electrical system ` Adjustable automatic sprinklers Sprinkler emergency cabinets: , • ` `, . '. •Dry automatic sprinklers . Sprinkler wrenches • Intermediate level sprinklers f -• Sprinkler escutcheons and guards • Open sprinklers Inspectors test connections t • • Spray nozzles Sight drains , - • Alarm valves Ball drips and drum drips f •Retarding chambers , Control valve seals `> • Dry pipe valves - ! Air'maintenance devices • Accelerators for.dry pipe valves Air compressors • Mechanical sprinkler alarms Pressure gaugesidentification signs • Electrical sprinkler alarm switches Fire department connection Water, flow detectors . t The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fre Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinlder contractors located throughout the United States, Canada and foreign countries. + Manufactured byRecycled The Reliable Automatic Sprinkler Co., Inc. 11111111111M.ne. . 'ti (800) 431-1588 Paper , Sales Offices • (800) 848-6051 bid Sales Fax Revision lines indicate updated or new data ' (914) 829-2042' Corporate Offices ' www.reliablesprinkler.com Inteet Address EG. Printed in Us.A o9/10 PM s99ss�°zas, - rn 3�,56585-Village Dr, "La Quinta, CA ' , ` ` LCI Project No. LPI 3023 ` Summary of Laboratory Tests (ASTM.D1557) Y1„ fit ��N, `+�?;•- °�� tfi7n•.�_=„�1 « .�. .Ar�� r�4 • - •.. ' L T L i. i �C 4 LF• '�. ,�Y ' cn���Y+T`�. .,. JP-yy'_.� •�' �T' �iP. �P3P��'. ' � y �V�. g�= L• S y`A fy iI . � i 1 m 01 ._ : .' - 13,rown Silty Sand Olive 1 1 Legend for Summary Sheet + • ; • - Abbrev. For Test Elev. L -Abbrev. for. r A6brev. For ' a Test Type , Notes PG'=Pad Giade - . BSG =Below Subgrade/Padgrade N =Nuclear Gauge k• -P =Pass ,1 BOF =Bottom of Footing 'ASTM D-6938 (soil/agg) F =Fail e • rade SubgJ Legend for Summary Sheet + • ; • - Abbrev. For Test Elev. L -Abbrev. for. r A6brev. For ' a Test Type , Notes PG'=Pad Giade . BSG =Below Subgrade/Padgrade N =Nuclear Gauge k• -P =Pass ,1 BOF =Bottom of Footing 'ASTM D-6938 (soil/agg) F =Fail e rade SubgJ ASTM D2950 (AC) f" • =notNSG=Native available S =Sand Cone ,' •` =information BED =Bedding _ ASTM D-1556 only ' . y PZ =Pipe Zone MT•=Midtrench TT '-Top of Trench, , • BSG =Below Subgrade/Padgrade r. ' S✓. V: y '• SG =Subgrade' BG =Base Grade BC =Base Course (AC) • `FC -Finish Course (AC) LandMark Consultants, Inc. t Landmark Consultants, Inc. Compaction - '' Test Summary' Client: Bill Lawson ,1 Project: 56585 Village Dr, La Quinta, 'CA Project No.: LP13023 Test of: house Pad 1 � ����( �' � ,1 � �i � 1 Ti �i S' A'M i F` S�i� 1 1 7iYll i. fsl}.. �...�Z3'S. +5 {L3'��*� � i`•j 1��;F�'�1L'� � i � 1 � I 1 s�' r q � 1 � 1 • 1 1 d r � 1 �'� 36'W x I 6N of SE comer 48'W of SE comer 2FE x 18'N of SW comer I O'E x 18'N of SW comer �� ■tea■�®■■ ®® ■vim■�®■■ 4 ' yes �eKCP,... HVAC SYSTEMS Qty. Heating 1 Central Furnace 1 Central Fumaqe HVAC DISTRIBUTION Location He, HVAC System - Zone 1 Ducted HVAC System - Zone 2 Ducted WATER HEATING Qty. Type 1 Small Gas ig Sidefins PERFORMANCE CERTIFICATE: Residential Part 1 of 5), CF -1 R SHGC Project Name Mr. BILL LAWSON Bug Screen Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/7/2012 0.300 Project Address 56585 Village Drive La Quinta none California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3, 390 _ . Addition n/a # of Stories 1 0.31 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status 0.300 Slab Unheated Slab -on -Grade None 3,480 Perim = 0' New Wall Wood Framed R-21 5,587 New 0.300 Door Opaque Door None 48 New Roof Wood Framed Attic R-38 3,390 Radiant Barrier New HVAC SYSTEMS Qty. Heating 1 Central Furnace 1 Central Fumaqe HVAC DISTRIBUTION Location He, HVAC System - Zone 1 Ducted HVAC System - Zone 2 Ducted WATER HEATING Qty. Type 1 Small Gas ig Sidefins FENESTRATION Orientation Aeea(ft) U_ Factor SHGC Ove Bug Screen Right (N) 138.0 0.300 0.31 none none BIAM Rear (W) 111.0 0.300 0.31 10.0 Rear (W) 120.0 0.300 0.31 15.0 Leff (S) 15.0. 0.300 0.31 23.0 Front (E) 71.0 0.300 031 no Right (NE) 4.0 0.300 0.31 none Rear (W) 71.0 0.300 0.31 none Left (S) 130.0 0.300 0.31 none HVAC SYSTEMS Qty. Heating 1 Central Furnace 1 Central Fumaqe HVAC DISTRIBUTION Location He, HVAC System - Zone 1 Ducted HVAC System - Zone 2 Ducted WATER HEATING Qty. Type 1 Small Gas ig Sidefins Exterior Shades none Bug Screen none Bug Screen 13.0/5.0 Bug Screen, 0.0/23.0 Bug Screen none none S re none BIAM none .. Bu§LSre rEb I Min. Eff Cooling 80% AFUE Split Air Conditioner 80% AFUE Split Air Conditioner DATE 1 JVS Min. Eff Ter 13.0 SEER Setback 13.0 SEER Setback Cooling Duct Location Ducted Attic, Ceiling Ins, vented Ducted Attic, Ceiling Ins, vented Gallons Min. Eff Distribution 50 0.65 Kitchen Pipe Ins Status New New New rdffleN BY tat Status New New Duct R -Value Status 8.0 New 8.0 New Status New EnerovPro 5.1 by EneravSoft User Number: 5732 Run Code: 2012-08-07708:09:19 ID: Corr0807121vU - - AAaW f of 01A Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/2012 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mt: BILL LAWSON Building Type ❑ Single Family ❑ Addition Alone ❑ Multifamily ❑ Existing+ Addition/Alteration Date 8/7/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written. justification and documentation, and special verification to be used with the performance approach. The enforcement agency • determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 623.0 ft2 Covered Slab Floor, 4:000" thick at Zone 1 - Off, Master, Great. HIGH MASS Design - Verify Thermal Mass: 1,141.0 ft2 Exposed Slab Floor, 4.000" thick at Zone 1 - Off, Master, Great HIGH MASS Design -Verify Thermal Mass: 1,716.0 ft' Exposed Slab Floor, 4.000" thick at Zone 2 -Main House The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. Y.k - - r ' , � � • '. y : a,, ''(�.A; - � X11 -y :�.. d':r•... ,;r Pr '-K i•. HERS REQUIREDWERIFICATIONt• Items irrthis section require field testing and/or verification fjy'a certified HERS Rater The inspector must receive a completed CF -4R form for each of the measures listed below for final t6 be giv6n. The Cooling System YorkCZB60. PS8CN 100. 2000cfm includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System - Zone 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System - Zone 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System YorkCZB60.PS8CN100.2000cfm includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System- Zone 2 incorporates HERS Verified Refrigerant Charge ora Charge Indicator,Display. The HVAC System HVAC System - Zone 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. r. Ener Pro 5.1 7y Ener Soft User Number: 5732 RunCode: 2012-08-07708:09:19 ID: Corr080712 Page 2 of 61 Reg: 212-N0042601A-000000000-0000 Registration Date/Time: 2012/08/07 11:37:41 HERS,Provider:'Ca10ERTS, Inc `r Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/20.12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name • Building Type ❑ Single Family ❑ Addition Alone Date Mr. BILL LA WSON ❑ Multi Family ❑ Existing+ Addition/Alteration 8/7/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.54 5.39 0.15 Space Cooling 68.28 61.64 6.64 Fans 13.40 15.86 -2.46 Domestic Hot Water 10.76 9.48 1.28 Pumps 0.00 0.00 0.00 Totals 97.98 92.37 5.61 Percent Better Th n Standard: 5.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof > Wall Area Area Number of Dwelling Units: 1.00 (E) 607. 71 Fuel Available at Site: Natural Gas (S) 969 145 Raised Floor Area: 0 656 302 Slab on Grade Area: 3,480 (N) 4,064 142 Average Ceiling Height: 10.5 Roof 3,390 0 Fenestration Average U -Factor: 0.30 TOTAL: 660 Average SHGC: 0.31 Fenestration/CFA Ratio: 19.5% REMARKS e� -t K STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Santiago Lopez-Ocampo 8/7/2012 Address P.O. Box 1018 Name City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and reco using duct design,. duct sealing, verification of refrigerant charge, insulation installation quality and eope sealing require installer testing andcertification and field verification by an approved HER rDesigner Dthaln,ce or Owner (per Business & Profe'ssions Code) Company CHARLES D. GARLAND - Architect/Struch I A (I Address 74-991 Joni Dr. #9. Name CHARLES D. GARLAND City/State/Zip Palm Desert, Ca 92211 Phone 760.340.3528 Signed License # Date Ene Po 5.1 SoRrb User Number- 5732 Run Code: 2012-08-07708:09:19 ID: Corr080712 Page 3 of 6 Reg: 212-N0042601A7000000000-0000 Registration Date/Time: 2012/08/07 11:37:41 HERS Provider: CalCERTS, Inc 'Z Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/2012, CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. BILL LAWSON Building Type ❑Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date - 817/2012 OPAQUE SURFACE DETAILS Surface IU Type Area Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 623 0.730 None 0 180 New 4.4.7-A1 Zone 1 -Off, Master, Greal Slab 1,141 0.730 None 0 180 New 4.4.7-A1 Zone 1 -Off, Master, Greal Wall 564 0:;069 R-21 0 90 New 4.3.1-A6 Zone 1 -Off, Master, Greal Wall 215 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 -Off, Master, Greal Wall 134 0.069 R-21 180 90 New 4.3.1-A6 Zone 1 -Off, Master, Gram Wall 241 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 -Off, Master,'Greal Wall 3,058 0.069 R-21 45 90 New 4.3.1-A6 Zone 1 -Off, Master, Great Door 24 0.500 None 45 90 New 4.5.1-A4 Zone 1 -Off, Master, Great Roof 1,674 0.025 R-38 0 18 New 4.2.1-A21 Zone 1 -Off, Master, Greal Slab 1,716 0.730 None 0 180 New 4.4.7-A1 Zone 2 -Wet, Kitchen,Bed2 Wall 276 0.069 R-21 0 90 New 4.3.1-A6 Zone 2 -Wet, Kitchen,Bed2 Wall 139 0.069 R-21 270 90 New 4.3.1-A6 Zone 2 -Wet, Kitchen, Bed[ Wall 690 0.069 R-21 180 90 New 4.3.1-A6 Zone 2 -Wet, Kitchen,Bedc' Wall 271 0.069 R-21 90 90 New 4.3.1-A6 Zone 2 -Wet, kitchen,Bedc' Door 24 0.500 None 90 90 New 4.5.1-A4 Zone 2-Wet,Kitchen,Bed2 Roof 1,716 0.025 R-38 0 18 New 4.2.1-A21 Zone 2 -Wet, Kitchen, Bed[ FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 5.6 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster - Lot Zone 1 -Off, Master, Great Window_ 30.0 0.300 NFRC 0.31 NFRC' 0 New JELD-WEN WindowMaster - Lo Zone 1 -Off, Master, Great -2 3 Window 4.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster - Lot Zone 1 -Off, Master, Great 4 Window 96.0 0.300 NFRC 0.31 NFRC 270 New JELD-WEN WindowMaster - Lot Zone 1 -Off, Master, Great 5 Window _ s. 15.0 0.300 NFRC 0.31 NFRC 270 New.-, - JELD-WEN WindowMaster-: Lot Zone 1 -Off, Master, Great, " 6 Window' 120.0 0.300 NFRC �+ _, 0.31 NFRC -270 New', JELD=WEN WindowMaster -.Lo Zone 1 -Off, Master, Great 7 Window 315.0 0.300 NFRC F 0.31 NFRC' : 180 New '= JELD-WEN WindowMaster - Lot Zone 1 -Off, Master, Great .8 Window 36.0 »"0.300 NFRC ? 0.31 NFRC.: , .,rf' '90 New.., JELD-WEN WindowMaster- Lo Zone -1 -Off, Master, Great 9 Window 5:0 o 0:300 NFRC 0.31 NFRC', r 90 New JELD-WEN WindowMaster - Lot Zone 1.-Off,.Master Great . 10 Window x 30.0 0 0.300 NFRC 0.31 NFRC ' X 90 New ; JELD-WEN WindowMaster - Lot Zone i -Off, I Master. Great 11 Window ` ". 4.0 . -0.300 NFRC - ' - -0.31 NFRC 45 New . JELD-WEN WindowMaster --Lot Zone 1 -Off," Master, Great 12 Window 15.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster- Lot Zone 2 -Wet, Kitchen, Bed2,Me 13 Window 15.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster - Lot Zone 2 4Vet,Kitchen,Bed2,Me 14 1 Window. 15.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster- Lot Zone 2-Wet,Kitchen, Bed2, Mec 15 lWindow. 1 18.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster- Lot Zone 2-Wet,Kitchen,Bed2,Me 16 Window 1, 18.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster- Lot Zone 2 -Wet, Kitchen, Bed2,Mac (1). Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hat Dist Len H t 1 'Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen. 0.76 4 Bug Screen 0.76 8.0 12.0 10.0 0.1 10.0 10.0 5 Bug Screen 0.76 6.0 3.5 10.0 0.1 10.0 10.0 ,6 Bug Screen s '0.76 10.0 12.0 15.0 0.1 2.5 2.5 2.5 13.0 0 2.5 5.0 0 7 Bug Screen 0.76 6.0 3.5 23.0 0.1 2.0 2.0 0.0 0.0 0 0.1 23.0 0 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 .12 Bug Screen 0.76 13 Bug Screen 0.761 1 14 Bug Screen 0.761 1 15 IBug Screen 0.761 1" 16 IBug Screen 1 0.761 1 EnergyPro 5.1 by Ener Soft User Number: 5732 - RunCode: 2012-08-07708:09:19 ID: Corr080712 Page 4 of 6 Reg: 212-N0042601A-000000000-0000 Registration Date/Time: 2012/08/07'11:37:41 HERS -Provider: CalCERTS, Inc , Electronically Filed by Santiago Lopez-Ocampo and Authenticated at Ca10ERTS.com - 8/7/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. BILL LAWSON Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date $/7/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Area Factor Cavity] Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments —Type FENESTRATION SURFACE DETAILS ID Type Area -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 —LI Window 1 .0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster- Lot Zone 2 4Vet,Kitchen,Bed2,Me 18 Window 15.0 0.300 NFRC 0.31 NFRC 270 New JELD-WEN WindowMaster- Lot Zone 2-Wet,Kitchen,Bed2,Me 19 Window 56.0 0.300 NFRC 0.31 NFRC 270 New JELD-WEN WindowMaster- Lot Zone 2-Wet,Kitchen,Bed2,Me 20 Window 36.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster- Lot Zone 2 -Wet, Kitchen, Bed2, Mec 21 Window 36.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster- Lot Zone 2 -Wet, Kitchen,Bed2,Me 22 Window 4.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster - Lot Zone 2 -Wet, Kitchen, Bed2, Mec 23 Window 4.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster - Lot Zone 2 -Wet, Kitchen, Bed2, Mec 24 Window 25.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster- Lot Zone 2-We1,Kitchen,Bed2,Me 25 Window 25.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster- Lot Zone 2. -Wet, Kitchen, Bed2, Mec (1) . U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H't 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 EnergyPro 5.1 by Ener Soft User Number: 5732 RunCode: 2012-08-07708:09:19 ID: Corr080712 Pa e 5 of 6 Reg: 212-N0042601A-060000000-0000 Registration Date/Time: 2012/08/07 11:37:41 HERS Provider: Ca10ERTS, Inc Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mt: BILL LAWSON Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date $/7/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existin Altered Removed Volume Year Built HVAC System - Zone 1 Zone 1 - Off,.Master, Great 1,674 18,414 HVAC System - Zone 2 Zone 2 - Main House 1,716 17,160 Totals 1 3,390 01 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System - Zone 1 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC System - Zone 2 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating____ Cooling Duct Location Duct:. R -Value Ducts Tested? Status HVAC System - Zone 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New System - Zone 2. Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New _HVAC ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor. or RE Standby Loss or Pilot Ext. Tank ° Insul. R- Value Status Rheem 41VRP50PT 1 Small Gas Kitchen Pipe Ins 40,000 50 0.65 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING ,t Control Hot Water Piping Length ft c o �C 0 cn a System Name Pipe Length Pipe Diameter Insul. ' Thick. Qty. HP Plenum Outside Buried En erg Pro 5.1 by En erg Soft User Number: 5732 RunCode: 2012-08-07708:09:19 ID: Corr080712 Page 6 of 6 Reg: 212-N0042601A-000000000-0000 Registration Date/Time: 2012/08/07 11:37:41 HERS Provider: CalCERTS, Inc - Cas if -'G PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1-13 Project Name I Mr. BILL LAWSON. Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+Addition/Alteration Date $/7/2012 Project Address 56585 Village Drive La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area X477 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 477 Perim = 0' New Wall Wood Framed R-21 913 New Door Opaque Door None 21 New Roof Wood Framed Attic R-38 477 Radiant Barrier New FENESTRATION U- Orientation Area(ftz) Factor Exterior SHGC Overhang Sidefins Shades Status Right (N) 15.0 0.300 0.31 none none Bug Screen New Rear (l� - _ 18.0 0.300 0.31 : none _ none Bug Screen - New Left (S) r t 54.0 0.300 0.31 none none `i Bug Screen e Front (E) ' ; 9.0 • 0.300 0.31 none no .- F L!- \ '\iQ U Irl `➢..7 /. \ ._ 01- WN FOR CONSTRUCTION 1 HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.20 HSPF Split Heat Pump 14.3 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System - Guest Hou Ductless/ with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 30 0.93 Kitchen Pipe Ins New AU EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2012-08-07708:12:41 ID: GH -C 0712 "Pagi U Uf 5 . v By E'lectrorrtically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS..com,- 8/•7/2012 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. BILL LAWSON Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 81712012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 477.0 ft2 Exposed Slab Floor, 4.000" thick at Guest Suite The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION: items in this'sectiori require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by EnerqySoft User Number: 5732 RunCode: 2012-08-07708:12:41 ID: GH-Corr080712 Page 2 of 5 Reg: 212-N0042602A-000000000-0000 Registration Date/Time: 2012/08/07 11:39:52 HERS Provider: Ca10ERTS,'Inc Fileptron�pally Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/2012 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type ❑ Single Family ❑ Addition Alone Date Mr. BILL LAWSON ❑ Multi Family ❑ Existing+Addition/Alteration $/7/2012. ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2-yr Space Heating 2.27 0.40 1.87 Space Cooling 76.61 84.77 -8.17 Fans 15.42 19.51 -4.09 Domestic Hot Water 46.51 23.48 23.03 Pumps 0.00 0.00 0.00 Totals 140.81 128.17 12.65 Percent Better Than Standard: 9.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 185 9 Fuel Available at Site: Natural Gas (S) 330 54 - Raised Floor Area: 0 (tM 185 18 Slab on Grade Area: 477 (N) 330 15 Average Ceiling Height: 10.0 Roof 477 0 '. Fenestration Average U -Factor: 0.30 TOTAL: 96 Average SHGC: 0.31 Fenestration/CFA Ratio: 20.1 %' REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Santiago,Lopez-Ocampo 817/2012 Address P.O. Box 1018 Name City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms an sheets, with the specifications, and with any other calculations submitted with this permit,application, and r pg jze t compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation ality, uil ' g envelope sealing require installer testing and certification and field verification by an approvedERSa Designer or Owner (per Business & Professions Code) C I l Company CHARLES D. GARLAND-Architect/Structs t �ej/� Address 74-991 Joni Dr. #9 Name CHARLES D. GA City/State/zip Palm Desert, Ca 92211 Phone 760.340.3528 Signed License # Date EnergyPro 5.1 by EnerQySoft User Number 5732 Run Code: 2012-08-07rO8:12:41 ID: GH-Con,080712 Page 3 of 5 Reg: 212-N0092602A-000000000-0000 Registration Date/Time: 2012/08/07 11:39:52 HERS Provider: CalCERTS, Inc r2 Electronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. BILL LAWSON Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/7/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 477 0.730 None 0 180 New 4.4.7-A1 Guest House Wall 315 0.069 R-21 0 90 New 4.3.1-A6 Guest House Wall 146 0.069 R-21 270 90 New 4.3.1-A6 Guest House Door 21 0.500 None 270 90 New 4.5.1-A4 Guest House Wall 276 0.069 R-21 180 90 New 4.3.1-A6 Guest House Wall 176 0.069 R-21 90 90 New 4.3.1-A6 Guest House Roof 477 0.025 R-38 0 18 New 4.2.1-A21 Guest House FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 15.0 0.300 NFRC 0.31 NFRC 0 New JELD-WEN WindowMaster - Lot Guest House 2 Window 18.0 0.300 NFRC 0.31 NFRC 270 New JELD-WEN WindowMaster - Lot Guest House 3 Window 18.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster - Lot Guest House 4 Window 18.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster - Lot Guest House 5 Window 18.0 0.300 NFRC 0.31 NFRC 180 New JELD-WEN WindowMaster - Lot Guest House 6 Window • 3.0 0.300 NFRC _ 0.31 NFRC 90 New JELD-WEN WindowMaster - Lot Guest House 7 Window 3.0 0.300 NFRC 0.31 NFRC 90 New JELD-WEN WindowMaster - Lot Guest House 8 Window 3.0 ' 0.300 NFRC 0.31 NFRC 90 New JELD-WEN WindowMaster - Lot Guest House (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len Hat Dist Len Hat 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-08-07T08:12:41 ID: GH-Corr080712 Page 4 of 5 Reg: 212-N0042602A-000000000-0000 Registration Date/Time: 2012/08/07 11:39:52 HERS Provider: CalCERTS, Inc E3cctronically Filed by Santiago Lopez-Ocampo and Authenticated at CalCERTS.com - 8/7/2012 CERTIFICATE OF COMPLIANCE: Residential (Part.5 of 5) CF -1 R Project Name Mr. BILL LAWSON Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/7/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC System - Guest House Guest Suite 477 4,770 , f Totals 1 4771 0 0 0 HVAC SYSTEMS _ System Name___ Qty. _ Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System - Guest House 1 Split Heat Pump 8.20 HSPF Split Heat Pump 14.3 SEER Setback - New HVAC DISTRIBUTION System Name Heating Duct. . _ Coolin Duct Location R -Value Ducts Tested? Status HVAC System -Guest House Ductless /with Fan Ductless n/a n/a ❑ New ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith PEC -30 1 Small Gas Kitchen Pipe Ins 35,000 30 0.93 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING c Control Hot Water Piping Length ft 0 0 i� v N a C System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 01 En erg Pro 5.1 by En erg Soft User Number: 5732 RunCode: 2012-08-07708:12:41 ID: GH-Con,080712 Page 5 of 5 Reg: 212-N0092602A-000000000-0000 Registration Date/Time: 2012/08/07 11:39:52 HERS Provider: CalCERTS, Inc