Loading...
05-2052 (SFD)IN a rtirica �e f Occupancy OF T19wJ Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and . the various ordinances of the City .'regulating building construction and/or use. BUILDING ADDRESS: 56-605 VILLAGE DRIVE Use classification: SFD Building Permit No.- 05-2052 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: KEITH & GENEVIEVE BUTENSHON Address: 682 34TH ST City, ST, ZIP: ASTORIA ORE 97103 By- STEVEN WILLETT -r" Date: 4-28-2006 uilding Offic,41 POST IN A CONSPICUOUS PLACE i - rw TITLE 24 REPORT Title 24 Report for: a Mr. & Mrs BUTENSCHON 56-605 VILLAGE -DRIVE La Ouinta, CA 92253 Project Designer: 'TELLEZ DESIGN AND ASSOCIATES 440 North Palm Canyon Dr. Palm Springs, CA 92262 (760) 778-0078 Report Prepared By: S.L.O. Santiago Lopez-Ocampo ..P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Numbe CITY OF ,(_q a QULNTA . BUILDING & SAFETY DEPT. • LQ060105 APPROVED. FOR CO TRUCTIO Date: oA 8/23/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: LQ060105 User Number: 5732 Certificate of Compliance: Residential (Part 1 of ?L CF -1 R' Mr. & Mrs BUTENSCHON Component 8/23/2005 Project Title Location/Comments Date 56-605 VILLAGE DRIVE La Quinta (attic, garage, typical, etc.) Project Address Wood Building Permit # Santiago Lopez-Ocampo (760) 485-8927. Plan check / Date Documentation Author Telephone -Exposed Slab w/R-0.0 Perimeter Insulation Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate zone Enforcement Agency Use Only GENERAL INFORMATION n/a 0.756 Total Conditioned Floor Area: 2,806 ft2 Average Ceiling Height: 11.0 ft, Total Conditioned Slab Area: 2,806 ft2 Exterior Door Building Type: Wood 0.060 (check one or more) 0.45 0.38 Single Family Detached ❑ Addition ❑ ❑ Single Family Attached ❑ Existing Building ` ❑ Multi -Family ❑ Existing Plus Addition 0.40 Front Orientation: (East) 90 de- Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 _ Number. of Stories: 1 ❑ Raised Floor FENESTRATION Shadina Devices Type Orientation Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38 2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 -Exposed Slab w/R-0.0 Perimeter Insulation R-19 Wall w/1" EPS Wood 0.045 Exterior Wall Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door None 0.387 Exterior Door R-19 GarageWall GYP + 5/8" GYP Wood 0.060 Exterior Wall 0.45 0.38 FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (East) 7.1 0.45 0.38 Bug Screen x❑ ❑ ❑ 0 Front (East) 43.0 0.60 0.39 Bug Screen Q' .❑ ❑ x❑ Left (South): 16.0 0.45 0.38 Bug Screen[g] ❑ ❑ X❑ Rear (West) 208.0 0.59 0.40 Bug Screen 0 ❑ ❑X❑ Right (North) 52.0 0.45 0.38 Bug Screen x❑ ❑ ❑ Q Left (South) 79.0 0.60 0.39 Bug Screen..x❑ ❑ ❑ x❑ Left (South) 6.0 0.59 0.39 Bug Screen X ❑ ❑ x❑ Rear (West) 119.8 0.45 0.38 Bug Screen 0 ❑ ❑ Q Right (North) 72.0 0.60 0.39 Bug ScreenX❑ ❑ ❑ 0 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ Run Initiation Time: 08/23/05 18:53:12 Run Code: 1124848392 Ener Pro 3.1 6y Ener Soft ' User Number: 5M Job Number: LQ060105 Page: 3 of 14 Certificate,of Compliance:* Residential (Part 2 of 2) CF -1 R Mr. & Mrs BUTENSCHON 8/23/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments f.Pntral Furnace 80% AFUE Ducts in Attic, 4.2 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner; Efficiency Location Duct . Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R=Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 47 Setback HVAC System WATER HEATING SYSTEMS Rated 1 Tank Energy Facti 1 ' External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby. Tank Insul. System Name Type Type' Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.Q- SMITH FPS -75-230 Small Gas Standard 1 7000 75 0.52 nia 12 11 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. , For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. RGMARKC :OMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate' has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Codej Documentation Author Name: Name: 1 Name: S.L.Q. ' Title/Firm: TELLEZ DESIGN AND ASSOCIATES Title/Firm: Santiago Lopez-Ocampo Address: 440 North Palm Canyon Dr. Address: P.O. Box 1018 Palm Springs, CA 92262 La Quinta, CA 92247 Telephone: 078 Telephone: (760) 485-8927 Lic. #: - (signature) (date) (signature) :. (date) Enforcement Ag cy Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 08/23/05 18:53:12 Run Code: 1124848392 . :nergyPro 3.1 By.EnergySoft User Number: 5732 , Job Number: LQ060105 . Page:4 of 14 Certificate of Compliance: Residential (Addendum) CF -1 R Mr. & Mrs BUTENSCHON - 8/23/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on ine adequacy or ine special Jusuncaaon and documentation submitted.Plan----f Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 428 sgft Exposed Slab Floor, 3.50" thick at Whole House. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 518 sgft Covered Slab Floor,. 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1860 sgft Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a.certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R: Plan Field i t Run Initiation Time: 08/23/0518:53:12 Run Code: 1124848392 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ060105 Page:5 of 14 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the,Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable bones or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. . Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑§150(c): X not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. -'§150(1)- Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118: insulation specified or installed meets insulation quality standards. Indicate type and form. IAI ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain, Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑%� §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑X § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ060105 Page:6 of 14 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents;the features noted shall be considered. by all parties as minimum component performance specifications for'the mandatory measures whether, they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT .Space Conditioning, Water -Heating and Plumbing System Measures:`(pontinued) X],'§150(m): Ductdand Fans �•: 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, '603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings 'shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL161A, or IJU81 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums'defined or constructed with materials other than sealed sheet metal, duct,board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. , 4. Exhaust fan systems have back draft or automatic dampers. • 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. „ 6. -Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight; moisture, equipment maintenance,- and'wind but not limited to the following: Insulation, exposed to weather shall be suitable ' for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water+ retardant and provides shielding from solar radiation that can cause degradation of the material. a§114: Pool and Spa Heating Systems and Equipment [ 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and. heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) EI§118 (f): Cool Roof material meet specified criteria Lighting Measures ® § 150(k)1: Luminaires for general lighting.in kitchens shall have lamps with an efficacy 40'lumens/watt or greater for . general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of. 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. . Computer Method Summary (Part 1 of 3)* C -2R Mr R Mrs RIJTFNS(.HON Project Title 8/23/2005 Date 56-605 VII I AGE DRIVE I a -(Minta Project Address Building Permit # ,Santiago Lopez-0rampo (760) 485-8927 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) . Design Design Margin Space Heating 4.35 4.98 -0.64 Space Cooling 40.22 38.29 1.92 Domestic Hot Water 10.16 10.24 -0.09 Totals 54.72 53.52 1.20 Percent better than Standard: 2.2 Total Conditioned Floor Area: 2,806 ft 2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Total Fenestration Area: 21.5% Number of Dwelling Units: 1.00 Total Conditioned Volume:. 30,866 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 21806 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC: System 9 80M$6b 1 00 CnnrlifinnPri Sethnnk _2 n/a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt . Rnnf 428 0.024 0 18 wall 151 0 045 _90_ 90 Wall 94 0 045 180 90 Wall 6 0.045 270 90 Wall 203 0-045 180 _90 Wall 122 0 045 270 90_ Wall 301 0.045 _0 90 Rnnf 2-378 0.024 Q 18 Wall 107 0 045 90_ 90_ W la I 28 0 045 180 90 Wall 80 0.045 90 90 Door 24 0.387 _90 _90 wall 140 0 045 90 Wall 6 0.045 270 90_ Wall 112 0 045 0 _90_ Wall 262 0 060 90 9.d nnnr 24 0 387 Wall 504 0 045 180 _990_ wall 52 0.045 270 90 (all 116 0.045 180 90 Wall 133 0.045 270 90 WaII 48 0 045 180 _9.Q WaII 52 0 045 270 -90 Wall 416 0 045 _(L _9.0_ Solar Gains Y / N Form 3 Reference Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ060105 Page:8 of 14 1 Computer Method Summary (Part 2 of 3) C -2R Mr. & Mrs BUTENSCHON 8/23/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1- Window Front (Fac -3.5 0 450 0.38 g0_ qQ GENERAL Aluminum Corp Low-FWhole House 2 Window Front (East) 9.0 0.600 0.39 90 90 GENERAL Aluminum Corp.Low-E Whole House 3 Window Front (East) 3.5 0.450 0.38 90 90 GENERAL Aluminum Corp.Low-E Whole House 4 Window Front (East) 9.0 0.600 0.39 90 90 GENERAL Aluminum Corp.Low-E Whole House 5 Window Left (South) 2.0 0.450 0.38 180 90 GENERAL Aluminum Corp.Low-E Whole House 6 Window Left (South) 2.0 0.450 0.38 180 90 GENERAL Aluminum Corp.Low-E Whole House L Window Rear (West) 48.0 0.590 0.40 270 90 GENERAL Aluminum Corp.Low-E Whole House 8 Window Front (East) 25.0 0.600 0.39 90 90 GENERAL Aluminum Corp.Low-E Whole House 6 Window Right (North) 18.0 0.450 0.38 0 90 GENERAL Aluminum Cor ow- Whole House 1Q Window Right (North) 18.0 0.450 0.38 0 90 GENERAL Aluminum Cor ow- Whole House 11 Window Right (North) 4.0 0.450 0.38 0 90 GENERAL Aluminum Corp.Low-E Whole House 12 Window Left (South) 30.0 0.600 0.39 180 90 GENERAL Aluminum Corp.Low-E Whole House 13 Window Left (, out 25.0 0.600 0.39 180 90 GENERAL Aluminum Corp.Low-F Whole House 14 Window Left (South 6.0 0.590 0.39 180 90 GENERAL Aluminum Corp.Low-E Whole House 15 Window Left (South) 6.0 0.450 0.38 180 90 GENERAL Aluminum Corp.Low-E Whole House 16 Window Left (South) 6.0 0.450 0.38 180 90 GENERAL Aluminum Corp.Low-E Whole House 17 Window Rear (West) 16.0 0.450 0.38 270 90 GENERAL Aluminum Corp.Low-E . Whole House 18 Window Rear (West) 64.0 0.590 0.40 270 90 GENERAL Aluminum Corp.Low-E Whole House _JR Window Rear (West) 24.0 0.450 0.38 270 90 GENERAL Aluminum Cor Low -E Whole House 20 Window Rear (West) 96.0 0.590 0.40 270 90 GENERAL Aluminum Corp.Low-E Whole House 21 Window Left (South) 24.0 0.600 0.39 180 90 GENERAL Aluminum Corp.Low-E Whole House 22 Window Rear (West) 16.0 0.450 0.38 270 90 GENERAL Aluminum Corp Low -E Whole House 23 Window Rear (West) 21.3 0.450 0.38 270 90 GENERAL Aluminum Corp.Low-E Whole House 24 Window Rear (West) 21.3 0.450 0.38 270 90 GENERAL Aluminum Corp.Low-E Whole House 25 Window Rear (West) 21.3 0.450 0.38 270 90 GENERAL Aluminum Corp.Low-E Whole House 26 Window Right (North) 24.0 0.600 0.39 0 90 GENERAL Aluminum Corp.Low-E Whole House 27 Window Right (North) 24.0 0.600 0.39 0 90 GENERAL Aluminum Corp.Low-E Whole House 28 Window Right (North) 6.0 0.450 0.38 0 90 GENERAL Aluminum Corp.Low-E Whole House 29 Window Right (North) 6.0 0.450 0.38 0 90 GENERAL Aluminum Corp.Low-E Whole House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 1.5 3.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 1.5 3.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 2.0 2.0 2.0 0 2.0 ---2-0 7 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 2.0 8.0 13.5 0.1 2.0 2.0 18 Bug Screen 0.76 8.0 12.0 13.5 0.1 2.0 2.0 19 Bug Screen 0.76 2.0 12.0 16.5 0.1 2.0 2.0 20 Bug Screen 0.76 8.0 12.0 16.5 0.1 2.0 2.0 21 Bug Screen 0.76 8.0 3.0 25.0 0.1 2.0 2.0 22 Bug Screen 0.76 2.0 8.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 8.0 2.7 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 8.0 2.7 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 8.0 2.7 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 29 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 Run• Initiation Time: 08/23/0518m5312 Run Code: 1124848392 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ060105 Page:9 of 14 ti Computer Method Summary (Part 2 of 3) C -2R Mr. & Mrs BUTENSCHON 8/23/2005 Project Title Date FENESTRATION SURFACES U- Act.. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 8.0. Window Right (North) 19n 0 600 0 39 0 q0 GFNFRAL Aluminum Corp Low-FWhole House • 31 Window Right (North) 12.0 0.600 0.39 0 90 GENERAL Aluminum Corp.Low-E Whole House I t INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin #' Exterior Shade -Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 6.0 2.0 2.0 0.1.— 2.0 2.0 31 Bug Screen 0.76 6.0 2.0 2.0 0.1 2.0 2.0 Run In* T*mem 08 Run Code* 1124848392 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ060105 Page: 10 of 14 Cooling Equipment . Minimum Duct Type (air conditioner, Efficiency. Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) •R -Value Type Comments Split Air Conditioner 12.0 SEER .Ducts in Attic 4.2 'Setback HVAC System .WATER HEATING SYSTEMS Ratedl Tank 'Energy Facts 1 Tank lnsul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name .Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%). Ext. A.O. SMITH FPS -75-230. Small Gas Standard 1 75,000 75 0.52 n/a 12 1 For small gas storage,(rated input <= 75000 Btu/hr), electric resistance and heat pump water.heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS ' Computer Method Summary (Part 3 of 3) C -2R Mr. & Mrs BUTENSCHON 8/23/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN ' 4 Area Thick. Heat Inside Location Type (so (in.) Cap._ Cond. Form.3 Reference R -Val. Comments Concrete Heavyght 428 3 50 98 0_ 98 njan Whole Houc - / Slah on ,rad Concrete. Heavyweight 518 3_50 28 0_98 n/a 2 Whole House / Slab on Grade Concrete, Heavyweight 1,860 3.50 0.98 n/a 0 Whole House / Slab on Grade + PERIMETER LOSSES F2 Insulation Type Length Factor R -Val Depth Location / Comments Slab Perimeter 86 0.76 0.0 0 Whole House a . Slab Perimeter 59 0.76 0.0 _ 0 Whole House Slab Perimeter 180 0.76 0.0 0 -Whole House - HVAC SYSTEMS r - Heating Equipment Minimum' Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat - ..Location/, pump, etc.) . (AFUE/HSPF)(ducts/attic, etc) R -Value• Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC item e Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. . Cooling Equipment . Minimum Duct Type (air conditioner, Efficiency. Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) •R -Value Type Comments Split Air Conditioner 12.0 SEER .Ducts in Attic 4.2 'Setback HVAC System .WATER HEATING SYSTEMS Ratedl Tank 'Energy Facts 1 Tank lnsul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name .Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%). Ext. A.O. SMITH FPS -75-230. Small Gas Standard 1 75,000 75 0.52 n/a 12 1 For small gas storage,(rated input <= 75000 Btu/hr), electric resistance and heat pump water.heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS ' Computer Method Summary (Addendum) C -2R Mr. & Mrs BUTENSCHON 8/23/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520: Ain EF below 0.58 requires an R-12 External Blanket.. The HVAC System "HVAC System" includes credit fora Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass`. 428 sgft Exposed Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 518 sgft Covered Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1860 sqft Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the'supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic. testing of these measures on a form CF -6R. Plan Field Run Initiation Time:"08/23105 18:53:12 Run Coder 1124848392 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: L0060105 Page:12 of 14 i PROPOSED CONSTRUCTION ASSEMBLY ENV=3 PROJECT NAME Mr. & Mrs BUTENSCHON DATE 8/23/2005 COMPONENT DESCRIPTION DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Membrane, Vapor -Permeable Felt 2 Gypsum or Plaster Board 3 Insulation, Mineral Fiber, R-19 4 Gypsum or Plaster Board 5 ASSEMBLY NAME R-19 Gara eWall GYP + 5/8" GYP 1.06 7 0.26 6 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 TYPE (check one) , X Wall LU W Ceiling I Roof FRAM FRAMING MATERIAL Wood 2.3 p Z FRAMING % 15 % Framingo /o 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTA Rc Rf R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Membrane, Vapor -Permeable Felt 2 Gypsum or Plaster Board 3 Insulation, Mineral Fiber, R-19 4 Gypsum or Plaster Board 5 2.87 6 1.06 7 0.26 6 s INSIDE SURFACE AIR FILM SUBTOTA Rc Rf R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ El El El El 0.170 0.010 0.625 6.000 0.500 19.002 5.940 0.450 0.450 2.87 0.37 SUBTOTA Rc Rf R -VALUE CAVITY . R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.0601 0.060 0.562 0.562 19.002 5.940 0.450 0.450 2.87 0.37 1.06 2.081 0.26 0.54 0.680 0.680 .20.92 7.86 -HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) , SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0478 X 0.85 ] 0.06 0.35 0.02 2.60. 0.26 0.68 2.87 0.37 1.06 2.081 0.26 0.54 7.6 TOTAL HC 2.3 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0478 X 0.85 ] + [ 0.1272I X 0.15 ] _ . 0.060 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 ByfnergySoft User Number: 5732 Job Number: LQ060105 Page: 13 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. & Mrs BUTENSCHON 8/23/2005 SYSTEM NAME FLOOR AREA HVAC Svstem 9 Rna Number of Systems 2 Heating System Output per System 65,000 Total Output (Btuh) 130,000 Output (Btuh/sqft) 46.3 Cooling System Output per System 58,500 Total Output (Btuh) 117,000 Total Output (Tons) 9.8 Total Output (Btuh/sqft) 41.7 Total Output (sgft/Ton) 287.8 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sqft) 1.43 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 1,585 28,609 0 1,230 38,796 0 1,430 1,940 0 0 0 0 0 0 0 0 0 1,4301 1,940 31,47:0[==0 42 676 York H4DH060/PDHUCO20L60 U&H 75,072 24,842 130,000 Total Adjusted System Output 75,072 24,842 130,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.5 of 69.5 of 100.10F Supply Air Ducts Outside Air rr 0 cfm 99.6 of Supply Fan Heating Coil 4000 cfm ROOMS 69.5 of 70.0 of Return Air Ducts m Temoeratures at Ti 111.0/77.6OF 74.3/62.1OF 74.3/62.2OF . 56.7/55.7OF Outside Air 0 cfm 74.3/62.10F Supply Fan Cooling Coil 4000 cfm h Return Air Ducts `S Supply Air Ducts 57.0 / 55.9 of 51.3% R.H. ROOMS 74.0 / 62.0 of EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ060105 Page: 14 of 14 1