12-0151 (AR)P.O. BOX 1504 VOICE (760) 777-7012
7$-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 4/30/12..
Application Number:�12-00000151 Owner.
Property Address: 56705-VILLAGE-DR�i BRUCE VOGEL
APN: 764-050-020- - - 56705 VILLAGE`DRIVE
Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253
Property. Zoning: LOW DENSITY RESIDENTIAL D
e
Application valuation: 12000
Contractor: APR 30 20.12
Applicant: Architect or Engineer: SUNTERRA BUILDERS
P.O. BOX 5217
LA' QUINTA, CA 92248 CITMOFLAQUINTA
(760) 902-0428 FINANCE DEPT
Lic". No.: 788530
V
LICENSED CONTRACTOR'S DECLARATION '
hereby affirm under penalty of perjury that I am licensed under provisionsof Chapter 9 (commencing with -
Section 7000) of Division 3 of the Busin ss and Professionals Code, and my License is in full force and effect.
Licensed.lassl B 4 nA License No.: 788530
ate.� IZ ntractor:
NER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are7not intended or offered for sale. If, however, the building or improvement is sold'within
one year of completion, the owner -builder will have the burden of proving that -he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contracdor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C: for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, -Civ. C.)•
Lender's Name:
Lender's Address:
7
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor'Code, for the performance of the work for which this permit is
issued.
�I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 9005774-12
,I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if'
Id become s 'ec to the workers' compensation provisions of Section
700 of the Labor I shall fo i omply with those provisions. "
ate: �� t1� icant: '
WARM G. FAILU E1 CURE WORKERS'(MPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENAL IES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the '
conditions and restrictions set forth on this application.
1. _ Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner; and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify tha I have read this application and state that aboveqEf
ee to comply withal] .
city and c my rdinances and state laws relating to builds coize representatives
of thiscoy t enter upon the above-mentioned propetty in
ta: �i ture (Applicant or. Agent)
Application Number 12-00000151
------ Structure Information 104SF PATIO ENCLOSURE/VB/RES-3/CL
A -FR ---'--
Other struct info CODE EDITION 2010
FLOOD ZONE NO
1ST FLOOR SQUARE FOOTAGE
104.00
- _ ---- -..- ---Permit----• _.BUILDING_.PERMIT_-
Additional desc .
Permit Fee 135:00 Plan Check Fee
87.75
Issue Date Valuation
12000
Expiration Date 10/27/12
Qty Unit Charge Per.
Extension
BASE FEE
45.00
10.00 .9.0000.THOU BLDG 2,001=25,000
90.00 -
Permit ELECT - ADD/ALT/REM
Additional desc .
Permit Fee 18.64 Plan Check'Fee
4.66
Issue Date Valuation . . . .
0
Expiration Date''. 10/27/12
Qty Unit Charge Per
Extension
BASE FEE
15.00
104.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY
------------------------------
3.64
Permit . . . MECHANICAL
Additional desc .
Permit Fee 19.50 Plan Check Fee
4.88
Issue Date . . . Valuation .. . . .
0
Expiration Date 10/27/12
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 4.5000 EA' MECH VENT INST/ DUCT ALT
4.50
Special Notes and Comments
104SF PATIO-ENCLOSURE/VB/RES-3/CLASS
A -FR [CONVENTIONAL] THIS PERMIT DOES NOT.
INCLUDE ALTERATION TO EXISTING FRAMING
OR PLUMBING INSTALLATIONS. 2010
CALIFORNIA BUILDING. CODES.
April 16, 2012 8:33:30 AM AORTEGA
-------------------------------------------------------------- --------------
Other Fees . . BLDG STDS ADMIN (SB1473-).
1.00
LQPERMIT .
-
Application' Number
12-00000151
------------------------------r----------------------------
Other Fees
ENERGY REVIEW
FEE
8.78
-
STRONG MOTION
(SMI) - RES.
1.20
Fee summary
Charged
Paid . Credited
Due
Permit Fee Total
173.14
.00
00
173:14
Plan -Check_ Total --
- - -9-7.29-----.
- 00 -
------- 00-----.-
—97.29 -
Other Fee Total
10.98
.00
..00
10.98
Grand Total
281.41,
00
.00
281.41
LQPERMIT
. (,Zttf�t2- .�v'tb�6�Zu►u. (�►rl�►�,s� �� • 0230 .
g . S fery•Dry ion -
P.O. Box .1504, 78-495 Calle Tampico
L4.Quinta, CA 92253 -:(760) 777-7012
uilding Permit Application and Tracking Sh et
Perinit # \
\�
Project Address: J� • 5V,
Owner's Name: GCT fXof L'
Address: s & • %S U -A-6 a,
A. P. Number. 7&4 d2s0 OZD
Legal Description: g 3
City, ST, Zip: '� L��
Contractor.
Telephone: . • - ,;. 3: .. ' .'• -
Address:
Project Description:
City, ST, Zip:
4SA3C1t—Bab
Telephone: .2 E��
]E.ritv
MState Lic. #: Lic. M.
2*42 a TM .
Arch., Engr., Designer. A.�.+le,Tt�
0
Address: 4S-0
City., ST, Zip: U(A?rAw-
Telephoae:`JW . - oT
-✓, ~
i-;;,�;w-�,;�
. Construction Type: . Occupancy:
State Lic. #: -
project type (circle one): New dd'n Alter Repair Demo
Name of Contact Person.
Sq. Ft.: 104 # Units:
Estimated Value of Project~ 2 .e7
Telephone # of Contact Person: •� ` S�8. 0
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES.
Plan Sets
p?
Plan Check submitted ?
it. Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit.
Truss Calcs.
Called Contact Person
Pian Check Balance
Title 24 Calcs.
Plans picked up 3
Z
Construction
Flood plain plan
Plans resubmitted •' .
Mechanical
Grading plan
2•4 Review, ready for correcti SP a
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M I.
H.O.A. Approval
Plans resubmitted
Grading
IN ROME:-
'^' Review; ready for correctionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
. (,Zttf�t2- .�v'tb�6�Zu►u. (�►rl�►�,s� �� • 0230 .
C chella Valle Unified School District
Valley. _ � ; . This Box For District Use Only
837733 Avenue 55: Thermal, :CA 92274 DEVELOPER FEES PAID .:
(760):398!-5909 — Fax: (760) 398-1224
ARCA: . .
AMOUNT
LEVEL ONE AMOUNT::
:LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMW' IND,AMOUNT:
DATE: '- -
•RECL•IPT: '-
CHECKN:
INITIALS
CERTIFICATE OF COMPLIANCE
.:.::.: (California Education C6de:1.7620)
Project Name:he?Palm Date: April 30, 2012..
Owner's Name:. Bruce:Vogel
} - Phone No. 760.-702-
.5772
Project Address: 56-705 Village Drive, LAQuinta, CA
Project Description':'*: Patio Enclosure
APM. . ;764-050-020
- :.:::.: Tract: #:::.: ::.: Lot #'s:' : ...::... ..
q. r
Type of Development:::.: Residential ...: AX! .,'Commercial': .:.:::.: Industrial.
Total Square Feet of Building Area: ...104
Certification.of Applkant/Owners:. -The person signing certifies that the above information is correct and makes this statement under'
penalty of perjury and further represents that he/she:is.authoriz to sign on behalf'of the owner/developer::
Dated: ... April 26, 2012 .. .. ... :Signature:.. ..
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN:OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE.OF THE FOLLOWING:. (CIRCLE ONE). .
Education Code,; : .;: Gov. Code:,; : .:: Project::,:: Agreement; Existing =Not Subject to Fee
.7620 65995 Approval Prior'to '1%1/87 _ Requirement . .
:.. Note:
Number of Sq.Ft.: 104
Pu
... sof
:Pursuant to AB 18.1 :any room additions. or :enclosure 500 :
sq. ft. or less are exempt from developer fees.' Any mobile
Amount:per'Sq.Ft. $0
homes being,relocated within:the same school district's,:;
Amount Collected $0
{r�
jurisdiction are• exempt from* developer fees..
Building Permit Application Comple"ped:: Yes/No
By: ;Elsa F. Esqueda, Director: of Facilities and: Maintenance
as
Certificate.issued by Laurie Howard, -Secretary Signature:y..
NOTICE OF 90 DAY.PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES =
Section 66020 of the:Goverrirnent Code asserted by Assembly Bill 3081, effectiveJanuary 1, 1997, requires that this District prdvide f l);a written notice to the
project appellant, at the time:of payment of school fees, mitigation payment or othei:exactions ("Fees" ), of the 90 -day period to protest. the imposition of these
Fees and (2) the, amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you .that the 90 -day protest period in regard to such Fees or. the validity thereof, commences with the payment.of:the fees or performance of any other
requirements as described in section 66020 of the Government code: Additionally, the amount of the fees imposed is as herein set forth,, whether payable at this .
time or in whole or in. part: prior to issuance: of :a, Certificate of Occupancy. As in the latter, the 90 days _starts on the date hereof. This Certificate of
Compliance is valid for thirty. (30) days from the, date of issuance. Extension will be: granted only for good cause, as determined by: the School District, and up
to three (3) such extensions may be granted.
\•1V:cfmydix ldevfeeslcenificate ot`coni(ilvice form Updated 3-2007
::-11/2010
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Vogel Residence
56-705 Village Drive
La Quinta, CA
Project Designer:
Lench Design Studio, Inc.
P.O. Box 450
La Quinta, Ca 92247
760-578-1077
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
MAR 2 6 2012
0/Zfb/ZU_I Z
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.,
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-03-26T14:41:49 ID:
e
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Vogel Residence
56-705 Village Drive
La Quinta, CA
Project Designer:
Lench Design Studio, Inc.
P.O. Box 450
La Quinta, Ca 92247
760-578-1077
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
MAR 2 6 2012
0/Zfb/ZU_I Z
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.,
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-03-26T14:41:49 ID:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary • 10
HVAC System Heating and Cooling Loads Summary 13
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Vogel Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
3/26/2012
Project Address
56-705 Village Drive La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,989
Addition
104
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 2,780 Perim = 86' Existing
Wall Wood Framed
R-13 1,154 Existing
Door Opaque Door
None 20 Existing
Roof Wood Framed Attic
R-22 2,780 Existing
Slab Unheated Slab -on -Grade
None 104 Perim = 22' New
Wall Wood Framed
R-13 293 New
Roof Wood Framed Attic
R-38 104 New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (E) 13.8 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 3.8 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 30.0 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 3.0 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 3.8 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 25.0 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 3.8 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 45.0 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 8.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (lM 36.0 0.710.
0.73 2.0 none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number.' 2655 RunCode: 2012-03-26714:41:49 ID:
Pa e 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Vogel Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
3/26/2012
Project Address
56-705 Village Drive La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,989
Addition
104
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Rear (tM 12.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (tM 24.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (lM 96.0 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 3.8 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 25.0 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 25.0 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 20.0 0.710
0.73 2.0 none Bug Screen New
Rear (lM 27.0 0.710
0.73 2.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-03-26T14:41:49 ID:
Page 4 of 13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Vogel Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
3/26/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
EnemvPro 5.1 by Ene Soft User Number: 2655 RunCode: 2 01 2-03-2 6 714:41:49 ID: Page 5 of 13
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1R_
Project Name
Building Type m Single Family ❑ Addition Alone
Date .
Vogel Residence
1 ❑ Multi Family m Existing+ Addition/Alteration
1312612012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin ,
TDV kBtu/ft2- r
Space Heating 5.13 4.41 0.72
Space Cooling 123.80 118.51 5.28
Fans 26.79 25.63 1.16
Domestic Hot Water 21.21 21.21 0.00
Pumps 0.00 0.00 0.00
Totals 176.94 169.77 7.17
Percent Better Than Standard: 4.1%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 450 51
Fuel Available at Site: Natural Gas (S) 450 110
Raised Floor Area: 0 (tM 570 195
Slab on Grade Area: 2,884 , (N) 450 98
Average Ceiling Height: 9.0 Roof 2,884 0
Fenestration Average U -Factor: 0.71 TOTAL: 453
Average SHGC: 0.73 Fenestration/CFA Ratio: 15.2%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
32620 2
Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Si ed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelop sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Lench Design Studio, Inc. /^1 ,� cy,�_ <
P.O. Box 450 P e'tV4
Address Name' ` l
City/State/Zip La Quinta, Ca 92247 Phone 760-578-1077 i License # Date
Ener Pro 5.1 by Ener Sok User Number: 2655 RunCode: 2012-03-26714:41:49 ID: Page 6 of 13
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5) CF -1 R
Project Name
Vogel Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family la Existing+ Addition/Alteration
Date
1312612012.
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
2,780
0.730 None
0
180 Existing4.4.7-A1
ExistingLiving
Wall
379
0.102 R-13
90
90 Existing4.3.1-A3
ExistingLiving
Door
20
1.450 None
90
90 Existing4.5.1-A1
ExistingLiving
Wall
240
0.102 R-13
180
90 Existing4.3.1-A3
ExistingLiving
Wall
282
0.102 R-13
270
90 Existing4.3.1-A3
ExistingLiving
Wall
252
0.102 R-13
0
90 Existing4.3.1-A3
ExistingLiving
Roof
2,7801
0.043 R-22
90
0 Existing4.2.1-A6
ExistingLiving
Wall
200
0.102 R-13
270
90 Remove 4.3.1-A3
ExistingLiving
Slab
104
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
100
0.102 R-13
180
90 New 4.3.1-A3
Addition
Roof
104
0.025 R-38
90
0 New 4.2.1-A21
Addition
Wall
93
0.102 R-13
270
90 New 4.3.1-A3
Addition
Wall
100
0.102 R-13
0
90 New 4.3.1-A3
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
13.8 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing Living
2
Window
3.8 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing Living
3
Window
30.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing Living
4
Window
3.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing Living
5
Window
3.8 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
6
Window
25.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
7
Window
3.8 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
8
Window
45.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
9
Window
24.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
10
Window
8.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
11
Window
36.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
12
Window
12.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
13
Window
24.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
14
1 Window
96.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
15Window
1
64.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
ExistingLiving
16
lWtndow 1
24.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt I RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
6.8 2.5
2.0 0.1
2.0 2.0
2
Bug Screen
0.76
2.5 2.5
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
5.0 2.5
2.0 0.1
2.0 2.0
4
Bug Screen
0.76
2.0 1.5
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
2.5 1.5
2.0 0.1
2.0 2.0
6
Screen
0.76
5.0 2.5
2.0 0.1
2.0 2.0
_Bug
7
Bug Screen
0.76
2.5 1.5
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
5.0 3.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
6.0 2.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
2.0 2.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
6.0 2.0
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
2.0 2.0
2.0 0.1
2.0 2.0
13
Bug Screen
0.76
2.0 12.0
2.0 0.1
2.0 2.0
14
Bu Screen
0.76
8.0 12.0
2.0 0.1
2.0 2.0
15
!Bug Screen
0.76
8.0 8.0
2.0 0.1
2.0 2.0
16
IBug Screen
0.76
8.0 3.0
2.0 0.1
2.0 2.0
EnergyPro
5.1 by EnerqySoft User Number. 2655 RunCode: 2012-03-26714:41:49 ID:
Pae 7 of 13
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Vogel Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1312612012
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
U -Factor SHGC
Azm Status Glazing Type Location/Comments
17 Window 15.0
0.710 Default 0.73 Default
0 Removed Double Metal Clear Existing Living
18 Window 3.8
0.710 Default 0.73 Default
0 Existing Double Metal Clear Existing Living
19 Window 25.0
0.710 Default 0.73 Default
0 Existing Double Metal Clear Existing Living
20 Window 25.0
0.710 Default 0.73 Default
0 Existing Double Metal Clear Existing Living
21 Window 20.0
0.710 Default 0.73 Default
0 New Double Metal Clear Existing Living
22 Window 27.0
0.710 Default 0.73 Default
270 New Double Metal Clear Addition
(1) Ll -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window
SHGC H t Wd
Ove hang Left Fin Right Fin
Len I Hot LExt I RExt Dist Len Hat Dist Len H t
17 Bug Screen
0.76 6.0 2.5
2.0 0.1 2.0 2.0
18 Bug Screen
0.76 2.5 1.5
2.0 0.1 2.0 2.0
19 Bug Screen
0.76 5.0 5.0
2.0 0.1 2.0 2.0
20 Bug Screen
0.76 5.0 2.5
2.0 0.1 2.0 2.0
21 Bug Screen
0.76 6.8 3.0
2.0 0.1 2.0 2.0
22 Buq Screen
0.76 4.5 2.0
2.0 0.1 2.0 2.0
Ener Pro 5.1 by Ener Soft
User Number: 2655 RunCode: 2012-03-26714:41:49 ID: Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Vogel Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1312612012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
Living Zone Existing Living
2,885
25,965 1981
Addition
104
832
Totals 1041 2885 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone 2 1 Central Furnace
80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
AO SMITH PEC -0.40
1
Small Elec.
No Pipe Insulation
15,359
40
0.91
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
c
_ o
id
Q �
—
System Name
Pipe
Length_
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
11
❑
Ener Pro 5.1 by EnergySoft User Number: 2655
RunCode: 2012-03-26714:41:49 ID:
Page 9 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R
Project Name
Vogel Residence
Date
3/26/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111(a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight-fiffing tight-fittingdamper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoff User Number: 2655 RunCode: 2012-03-26T14:41:49 ID: Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Vogel Residence
3/26/2012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
1 50 m 7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-03-26714:41:49 ID: Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Vogel Residence
3/26/2012
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-03-26714:41:49 ID: Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Vogel Residence
Date
3/26/2012
System Name
Living Zone
Floor Area
2,989
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 5,174
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 56,000
48,803
3,712 1,620
39,013
Total Output Btuh 112,000
0
Output Btuh/s ft 37.5
4,138
2,772
Cooling System
0
0
Out ut per System 46,000
0
0 0
0
Total Output Btuh 92,000
0
3,712
0
Total Output Tons 7.7
4,138
2,772
Total Output Btuh/s ft 30.8
Total Output s ft/Ton 389.9
1 57,080
44,557
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow cfm
4,420
Existing 49,965
37,993
112,000
Airflow cfm/s ft
1.48
Airflow cfm/Ton
576.5
Outside Air %
0.0%
Total Adjusted System Output 1 49,965
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK'
37,993
Aug 3 PM
112,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
I Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Outside Air
0 cfm Supply Fan .
AL 4,420 cfm
69 OF
69 OF 93 OF
Heating Coil
93 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 79/69°F
Outside AirAr
0 cfm AL
79 / 69 OF
79/69°F 68/66°F
4O,
c
Supply Fan Cooling Coil 69 / 66 OF
4,420 cfm
64.4% ROOM
78 / 69 °F
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-03-26714:41:49 ID:
Page 13 of 13
-
�u
0
P.O:,BOX 1504 BUILDING & SAFETY DEPARTMENT
$lo
`� 78-495 CALLE TAMPICO•
_ (760),777-7012
9�
Of- T1 Lp•QUINTA,�CALIFORNIA 92253 ' •FAX 7.60 777-7011
,t
-
` Finance Department, Please Collect The Following Fees For The Services Rendered
.y as .• A.
..1 '. .. _�_...,_�__• • -,
HTE APPLICATION NUMBER: See Below?
t �
�_•.� +°.
'
PROJECT: PATIO ENCLOSURE
ADDRESS: 56-705 VILLAGE DRIVE:
r
CUSTOMER: BRUCE`VOGEL `
SERVICES RENDERED: PLAN REVIEW FROM PREVIOUSLY WITHDRAWN
APPLICATION AND BUILDING PERMIT FEES FOR
,. NEWLY PROPOSED PATIO ENCLOSURE
'CONST RUCTION.
_ WITHDRAWN PLAN REVIEW FEE —APPLICATION: 10-0236
7/7/2010: .. ........ ' . $ 195.83
°
=
/PROPOSED CONSTRUCTION PERMIT FEE — APPLICATION: 12-0151
t ' `
{
4/16/2012 : ..........................:...................:.. $ x 281.41
�. g
�. EOTAL_FEES_NOW DUE:........................
...$-47,7.24
-
�u