BRES2016-01787&495 CALLE TAMPICO• V
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: '
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation: .
BRES2016-0178
56985 VILLAGE DR
764060004
KRISHNAN / 330SF ADDITION TO EXISTING GUEST HOUSE
$50,000.00
Applicant:
PREST VUKSIC ARCHITECTS INC.
44530 SAN PABLO
PALM DESERT, CA 92260
CfTY OF LA QUINTA
COMMUNITY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of.the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 396595
Date: ` o aZ •!A Contractor:
OWNER -BUILDER DECLARATION.
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to.its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760).777-7125
FAX (760)777=7011
INSPECTIONS (760) 777-7153
Date: 10/25/2016
Owner:
KALLIANA KRISHNAN
737 RICHARDSON DR
BRENTWOOD, CA 92253
Contractor:
SJR CONSTRUCTION COMPANY INC
Pb BOX 3305
PALM DESERT, CA 92261
(760)779-9399
Llc. No.: 396595
- WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by.
Section 3700 of the labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: EXEMPT Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in'any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the '
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: /(7/-Z :FApplicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION ERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINALPENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of.this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
'I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
i
Date 1 Signature (Applicant or Agent)
Date: 10/25/20.16
Application Number: BRES2016-0178
Owner:
Property Address: 56985 VILLAGE DR
KALLIANA KRISHNAN
APN: 764060004
737 RICHARDSON DR
Application Description: - KRISHNAN / 330SF ADDITION TO EXISTING GUEST HOUSE
BRENTWOOD, CA 92253
Property Zoning:
Application Valuation: $50,000.00
Applicant:
Contractor:
PREST VUKSIC ARCHITECTS INC.
SJR CONSTRUCTION COMPANY INC
44530 SAN PABLO
P 0 BOX 3305
PALM DESERT, CA 92260 _
PALM DESERT, CA 92261
(760)779=9399
Llc. No.' 396595
Detail; 330SF ADDITION OF TWO LIVING AREAS TO EXISTING DETACHED CASITA [ENGINEERED] THIS PERMIT DOES NOT INCLUDE REMODEL TO THE EXISTING
CASITA AREA. 2013 CALIFORNIA BUILDING CODES.
FINANCIAL O•
DESCRIPTION' ACCOUNT QTY AMOUNT
ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36
DESCRIPTION ACCOUNT QTY AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40
DESCRIPTION ACCOUNT QTY AMOUNT
ADDITION, FIRST 100 SF 10170000-42400 0 $120.83
DESCRIPTION ACCOUNT QTY AMOUNT
ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14
Total Paid for ADDITION: $371.73
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
1
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
1
$95.00
Total Paid for BLDG CITY STAFF - PER HOUR: $135.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$2.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SERVICES
101-0000-42403
0
$24.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SERVICES PC
101-0000-426000
$12.09
Total Paid for ELECTRICAL: $36.26
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-000042403
0
$145.03
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
-0
$47.86
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89
DESCRIPTION
ACCOUNT
QTY
AMOUNT
OTHER MECHANICAL EQUIPMENT
101-0000-42402
0-
$72.52
DESCRIPTION
ACCOUNT
QTY
AMOUNT.
OTHER MECHANICAL EQUIPMENT PC
101-0000-42600
0
$72.52
Total Paid for MECHANICAL: , $145.04
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$6.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $6.50
Bin, #
City of LA Qu%uta 1
Building a Safety Division
P.O. Box 1504,'78-49S Calle Tampico
La.Quinta, CA 92253 - (760) 777-7012
1` Building Permit Application and Tracking Sheet
Permlt #
_d ( (040,
Project Address: 56-985 Village Drive
Owner's Name:. Kal Krishnan
A. P. Number.
Address: 56-985 Village Drive
Legal Description:
Contractor.
City, ST, zip: La Qinta, CA 92253'
Telephone'
Address:
Proje4Description: Addition to the guest house.
City, ST, Zip: ,
Telephone:
State Lic. # : City Lic. #;
Arch., Bngr., Designer. David Prest
Address: 44-530 San Pablo STE 200
City., ST, Zip: Palm Desert6A92261
Telephone: .(760).779-5393 Construction Type: VB Occupancy: R-3'
State Lic. #: - C-8960 Project type (circle one): Newdd'n Alter Repair Demo
Name of Contact Person: Tatiana Barbuzza Sq. Ft.: 330#Stories: 1 - # Units:
Telephone # of Contact Person: (760)77/-5393
Estimated value of Project 50,000.00
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES -
Plan Sets
Plan Cheek submitted
JA
Item Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit. .
Trus Calcs.
Called Contact Person 1
Plan Check Balance
Tide 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted.-.
Mecharilcal
Grading plan
r Review, ready for correctionsrissue
Electrical
Subcoatactor List
Called Contact Person
Plumbing
Grant Deed
Pians picked up
SALL
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'''° Review; ready for correcdons/ime
Developer Impact Fee
Planning Approval
Called Contact Person
AXP.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
.Coachella Valle Unified School District.-:: y This Box For District Use Only ': : •' "
83-733 Avenue. 55; Thermal, :CA 92274 DEVELOPER FEES PA1D: '
..
(760).39_8=5909 — Fax. (760):398-1224 ;.
AREA: .. ..:: -
AMOUNT .. .. . .
.LEVEL ONE AMOUNT:' .'.
LEVEL TWO AMOUNT:'
MITIGATION AMOUNT:
COMM/IND.:AMOUNT:
RECEIPT:
..CHECK #: ' •' • ....
INITIALS '
CERTIFICATE OF COMPLIANCE
(California • Education Code 17620)
Project Name: he� Palms Date: " Ocfober 20, 2016
Owner's Name:.: Kal. Krishnan : - Phone No. 760-567=7310
Project Address: 56985 Village Dr.', La Quints
Project Description:_ 'Residental Addition'.::
APN:. .-764-060-004 Tract #: , Lot #'s:. ;
Type of Development:. " Residential.XX! Commercial Industrial
Total Square Feet of Building Area: ..330 sq: ft:
Certification of Appticant/Owners:..The'persoh signing certifies that the above infoiination is'correct and makes this statement under
penalty of per bry and further represents that he/she:is.authorized to sign on behalf of the owner/developer:
Dated:.. ..October 20;-2016.. Signature: ... ..�.' ..
SCHOOL DISTRICT'S REQUIREMENTS.FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN : -
ACCORDANCE WITH' ONE OF THE- FOLLOWING:. (CHICLE ONE).
Education Code: Gov. Code.• Project.- :`: Agreement: Existing Not Subject to Fee
.17620 65995 Approval Prior to l/1/87 Requirement;:
... ..... Note: .. .. ..... ...
Number of Sq.Ft. :330 Pursuant to AB:181 any room additions or enclosures of 500
' sq: ft. or less are exempf from developer fees'. `Any. mobile
Amount.per:Sq.Ft. $0.00 homes being -relocated within :the ;same school district's `
Amount Collected . $0.00 '
jurisdiction are exempt from developer fees,; "•
Building Permit:Application Completed: Yes/No
By: E sa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by.' Laurie Howard; Secretary . Signature:.. Y(
.NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT'OF FEES.. .
Section 66020 of the Government Code asserted by -Assembly Bill 3081, effective january 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees; mitigation payment or other exactions ("Feed% of the 90 -day period to protest;the imposition of these, :.
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that.the 90 -day protest period' in regard to such.Fees'or:the validity thereof; commences with the payment:of:the fees or performance . any other
requirements as'described in section 66020 of the Government code: Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. :As:in the latter, the 90 days'starts on the date hereof.: This Certificate of .
Compliance is valid for thirty. (30) days from the date:of,issuance. Extension will tie. granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.:
:, MV:c%inydocs/`de;vfees/aertificateofcontpliancetormupdated3-2007 :. :. i ;.11!2010
ARC � � of, . shall not constitute a representation, warranty, or guarantee that such plans and specifications
e,' { wit-, meed%, design, practices or zoning and building ordinances, or other governmental agency, regulations
42r The ARG shat not: be responsible for reviewing, nor shall its approval of any plans or design, be
d � � .mthe standpoint of structural safety or conformance with building or other codes. By approving
zsand m-cabom neither the ARC, the Members thereof, the Association, any Member thereof, their Board
CF, i aV Alerabers thereof, or the Declarant assumes any liability or responsibility therefore or for any defect it
t cxr�_- =6 o�n or knpovernent from such plans or specifications. As provided in the CC&R's neither the ARC, the
,,, a I of DUedors or the Association or any Members thereof not the Declarant or Developer shall b,
ft� is , Owner. Occupant, or other person or entity for any damage, loss or prejudice suffered or chime
a as`,t-af(l) Me aWaval or disapproval of any plans, drawings, or specifications, whether or not defective, or ('
-xtan or pedbmsance of any work whether or not pursuant to the approved plans, drawings,
%,are coagmation with the architectural review process is appreciated. If you have any questions, Ales
at X6-5100.
� d* VWAGE AT THE PALMS Architectural Review Committee
Tbe 1�ertwil Tl - Ott: DW*n
S BOW
V� ;
The Management Trust
OWNER INSPIRED. CHALLENGE ACCEPTED,
VILLAGE AT THE PALMS HOMEOWNERS ASSOCIATION
RECEIVED
: � t...
JUN 2 4 2016 -
XILEY WAY #302
`
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
' •:^ f' for, %,9W VILLAGE DRIVE
' f?cr�eovrr�-
•
vb�E ,�fttect=d ReeiOs Committee for VILLAGE AT THE PALMS has reviewed and APPROVED your architectural
t?ae 0.tion oi' desert landscape and removal of existing per the plans submitted.
ARC � � of, . shall not constitute a representation, warranty, or guarantee that such plans and specifications
e,' { wit-, meed%, design, practices or zoning and building ordinances, or other governmental agency, regulations
42r The ARG shat not: be responsible for reviewing, nor shall its approval of any plans or design, be
d � � .mthe standpoint of structural safety or conformance with building or other codes. By approving
zsand m-cabom neither the ARC, the Members thereof, the Association, any Member thereof, their Board
CF, i aV Alerabers thereof, or the Declarant assumes any liability or responsibility therefore or for any defect it
t cxr�_- =6 o�n or knpovernent from such plans or specifications. As provided in the CC&R's neither the ARC, the
,,, a I of DUedors or the Association or any Members thereof not the Declarant or Developer shall b,
ft� is , Owner. Occupant, or other person or entity for any damage, loss or prejudice suffered or chime
a as`,t-af(l) Me aWaval or disapproval of any plans, drawings, or specifications, whether or not defective, or ('
-xtan or pedbmsance of any work whether or not pursuant to the approved plans, drawings,
%,are coagmation with the architectural review process is appreciated. If you have any questions, Ales
at X6-5100.
� d* VWAGE AT THE PALMS Architectural Review Committee
Tbe 1�ertwil Tl - Ott: DW*n
S BOW
V� ;
YOUNG
ro@a a o� o D
ENGINERING
E
a
w:
Letter of Transmittal'
To: City of La Quinta Today's Date 7=7=2016
~� t
"-78-495 Calle'Tampico - City Due-Date:7-11-2016
^
La Qulnia,• CA 92253 - ' . Project'Address:'-
56985 VILLAGE DR '�
,Attn: 'Ramses Sevilla Plan Check #
BRES20'16-0"178;
< ;Submittal *. ®; 15�
❑ 4`h
�i a;,
2nd
❑ 5th
',3rd r❑
-Other.
,
We are forwarding. ® By Messenger ❑ By Mail (Fed Ex or.UPS) `' ❑ YourPickup '
R'•
<
' Includes: Descnptio,ns , • Includes
# Of " Descriptions
4
,Copies: -
<
Structural Plans +
❑ R .°Revised Struct. Plans'
StructuraF Calculations ` - '
❑ Revised Structs Calcs�
< ❑ ~r Truss Calcs :�.. �=
. �-
y .
❑ Revised Truss:Calcs
r
❑: '. d ' Soils`Report Update`,..
-Revised Soils Report',
'❑. �. Structural P/C Comments ''
O�• t R Approved Structural_Plans
:.
+ ` 'Redlined Structural•Plans _ ^❑
Y
4 `_ Approved Structural Calcis
R
El ;Redlined StrLickiral Calcs .' '- `
❑ s z ~' : Approved.Truss Calcs <
` . ,+ '; �' i' Rbdlined;Truss Calcs _ t ,��
Approved Soils Report '
+ - ❑ Redlined'Soils_ Reports
❑ :k Other,.`,,*'
Comments.. '': Structural content is'approvable.
:
.Transit Pet.
Admin Time - .25'HR :4
F
Structural- Engineer/Principal Review Tirrie' = O HR' -
R.
'Plan Review. Engineer. Time = 1 HR'
rom
Thisf
Mate'ri�aI :Sent
❑`; Your files ® PerYourRequest
Your: eview,
Approval
�' ;.. ❑'; Checking, Y.
°❑ At the 'request of ` #
Other: ❑
F
By BrQnz,Yourig
'Office- ® `(760).,772-51.07
F r r •
Othe❑ ',
'
•
�' if .. C,
3 <�F r ' �'- f • f y , 1
- R 4 lM1 k 4 " <
Plan SubmNW Dr
'Job Sde Addie
s ` r' (h�unwra.Nwi
Building Permit Number:
Project Description: Small Room Addition
Exampt: O
(Materials may contain.hazardous wastes and
are not iwbject.to recycling provisions)
Construction Debris Management Plan
10/24/2016
56985 Village Drive
Krishnan
56985 Village Drive
La Quinta, CA. 92253
:* ProJeedWanagerb�Nwnd
Steve Ruffolo
Projd&VManagers3Phone Number
760-567-7310
ProJecHManegera'Envail Address
davldDCdlrxestvuksicaarchitads.com
Builder /Contractor,
SJR COnStnJCtlOn
r ANumber `street or PO t3oz
49291 Mariposa Dr
crit' -*state Postal Code
Palm Desert, CA. 92260
Prolect`Square Footepe
Approx. 330 square feet
'q City Approval By-R4d%—DELA. t6x
Date of City Approval, b%2k
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse*
'Describe Items
Tons
172-51 Not recyclable
Recyclable
Recyclable
Recyclable
Recyclable
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
Totals: Rec cle Trash Projected :
1.7 1 1.31. 11 FS7.19%
1 understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 60% of the Jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or reuse, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is Issued in the name.of the property owner(s) and shall remain their property throughout the construction and/or
demolition project A contractor serving as agent of the owner may obtain a DNIP for the owner. However, the DMP Is still
Issued in the name of the propertyowner(s) and.the owner retains legal responalblilty. for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be keptiefonned of the diversion progress through
bl-monthly reports. if self -hauling,. all -refuse material from this project eke must be taken to an approved recycler or transfer
Owrier /Developer / Project Manager / Superintendent Date
BUILDING ENERGY ANALYSIS REPORT
i A
PROJECT:
Krishnan Residence,
56-985 Village Drive
La Quinta; CA 92253
' Project Designer:
F
Prest Vuksic Architects
44-530 San Pablo STE 200
Palm. Desert, CA 92261
.
(760) 779-5393
Report Prepared by:
Jon ,Scott
}�
Scott Design and Title 24, Inc;
74-818 Velie Way, STE 8 .
Palm Desert, CA 92260
,
(760) 702-5406
�DG �j ED
CITY OF L.A QUINTA �u� � � Nib
BUILDING & SAFETY DEPTH b Number: QUlNTA
ROVED. MU I v 0 ,60PMONT
'0M
FOR ONSTRUGTION
tt 1� Date:.
BY _
D
?-0I7/29L201B.
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This developed by EnergySoft, LLC
program —www.energysoft.com:
EnergyPro 6.7 bX EnergySoft User Number., 6712 ID:
is � �
a
�. -
.� ..
CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOOD
Project ame: Krishnan Residence Calculation Date/Time: 08:34, Wed, Jul 20, 2016
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml
COORF-01
Page 1 of 8
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Krishnan Residence
04
05
02
Calculation Description Title 24 Analysis
08
-
03
Project Location 56-985 Village Drive
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 982
15
Number of Zones 2
16
Slab Area (ft2) 982
17
Number of Stories 1
18
Addition Cond. Floor Area 330
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 330
21
Glazing Percentage (%) 31.9%
COMPLIANCE RESULTS
01 Building Complies viitl Computer,`Performbance
02- This building incorpoiates'featur ,that require field1est ngsand/or v' eerificat��ib�ri,by alcertifi d+HERS Yf5ter unde the supervision of a CECapproved HERS provider.
03 This building incorporates oneor4�more Special Features ihhown beiow � ' 0
Registration Number: 216-A0224228C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-07-20 08:41:06
Report Version - CF1R-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-07-20 08:35:32 ,
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
13.19
10.19
3.00
22.7%
Space Cooling
351.51
348.57
2.94
0.8%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
19.85
16.95
.2.90
14.6%
- Photovoltaic Offset
- - —_ - —
- - 0.00 _ _ . __.
_ _ . _ 0.00
Compliance Energy Total
384.55
375.71
8.84
2.3%
Registration Number: 216-A0224228C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-07-20 08:41:06
Report Version - CF1R-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-07-20 08:35:32 ,
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OHOD
Project ame: Krishnan Residence Calculation Date/Time: 08:34, Wed, Jul 20, 2016
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. '
• Window overhangs and/or fins
CF•RF-01
Page 2 of 8
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
High Quality Insulation Installation (QII)
Cooling System Verifications:
• — None —
HVAC Distribution System Verifications: t
• — None —
Domestic Hot Water System Verifications:
• — None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use.components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.? ''
Refe`r�ence Energy Usenergy; Design Ratingf Margin Percent Improvement
Total Energy (kTDV/f2-yr)* /'_ ' 451.17 z s, � ;,442 33 " � 8.84 2.0%
includes calculated Appliances and Miscellaneous Energy Use (AMEU
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Krishnan Residence
982
1
2
2
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
casita
Conditioned
HVAC1
652
9
DHW Sys 1
casita add
Conditioned
HVAC1
330
9
DHW Sys 1
Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 -Report,Generated at: 2016-07-20 08:35:32
i
CERTI#E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: Krishnan Residence Ca culation Date/Time: 08:34, Wed, Jul 20, 2016
Calculation Description: Title 24 Analysis Input File Name: Krishnan -PV 16.xml
CF*RF-01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
N Wall ex
casita
R-13 Wall
0
Front
455
0
90
Existing
No
E Wall ex
casita
R-13 Wall -
90
Left
633
56
90
Existing
No
S Wall ex
casita
R-13 Wall
180
Back -
455
0
90
Existing
No
W Wall ex
casita
R-13 Wall
270
Right
633
61.5
90
Existing
No
Roof
casita
Default prior To 1978
652
Existing
No
N Wall
casita add
R-21 Wall (W.21.2x6.16)
0
Front
455
36
90
New
N/A
E Wall
casita add
R-21 Wall (W.21.24.16)
90
Left -
455
40
90
New
N/A
W Wall
casita add
R-21 Wall (W.21.24.16)
270
Right
455
120
90
New
N/A
Roof 2
casita'add
R-38 Roof Attic
330
New
N/A
ATTIC
01
02� `
03
r04
1 0;5
� 06 _
07
08
09
10
Radiant
Statu
Verified Existing
Name%tatd
r> .Constructionype
%�t
,Roof Rise
mRoof Reflectance
Roof�Em��ttance
Barrier
Cool Roof
s
Condition
Attic casita
` Attic Roofta
Ventilated
3
E o.1
a.
0-x_85
No
No
Ex9ti
No
,>
n
Attic casita add
Attic Roofcasita add
Ventilated
3
0.1
0.85
No
No
New
No
Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-20 08:35:32
CERT-�TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE•HOD CIORF-01
Project Rame: Krishnan Residence Calculation Date/Time: 08:34, Wed, Jul 20, 2016 Page 4 of 8
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml
WINDOWS
01
02
03
-
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
-
Multiplie
Height (ft) r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
ex 8x5
E Wall ex (Left -90)
-
- 1
40.0
0.61
0.59
Insect Screen (default)
Existing
No
ex 2x2
E Wall ex (Left -90)
-
- 1
4.0
0.61
0.59
Insect Screen (default)
Existing
No
ex 2x2 2
E Wall ex (Left -90)
-
- 1
4.0
0.61
0.59
Insect Screen (default)
Existing
No
ex 2x2 3
E Wall ex (Left -90)
-
- 1
4.0
0.61
0.59
Insect Screen (default)
Existing
No
ex 2x2 4
E Wall ex (Left -90)
-
- 1
4.0
0.61
0.59
Insect Screen (default)
Existing
No
ex 4.3x5
W Wall ex (Right -270)
-
- 1
21.5
0.61
0.59
Insect Screen (default)
Existing
No
1 5x8
W Wall ex (Right -270)
5.0
8.0 1
40.0
0.32
0.25
Insect Screen (default)
New
N/A
D 4.5x8
N Wall (Front -0)
4.5
8.0 1
36.0
0.32
0.25
Insect Screen (default)
New
N/A
A 3.4x5 new hist
E Wall (Left -90)
-
- 1
17.0
1.17
0.89
Insect Screen (default)
New
N/A
Al 3.4x5 new hist
. E Wall (Left -90) �.
-
- 1
6.0
1.17
0.89
Insect Screen (default)
New
N/A
A2 3.4x5 new hist
E Wall (Left -90), a"-"'
-
- 1
17.0
1.17
0.89 1
Insect Screen (default)
New
N/A
E 3x8
1`W Wall (Right -270) =
Tj-
'A 24`.0
0.32
0,�5�
Insect Screen (default)
New
N/A
C 6x8
W Wall .(Righi-270)-°
- 1
�48)0�
0 3U
i 20
Insect Screen (default)
New
N/A
B 6x8
`.'W Wall (Right2270) - - 1
48.0
0.30
0.20
Insect Screen (default)
New
N/A
OVERHANGS AND FINS
01
02
03
04
OS
08
09.
10
11
12 13
14
OverhangLeft
Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
=Ht.*Depth
op Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
15x8
10
0.1
10
100
0
0
0
0
0
0
D 4.5x8
100.1
10
100
0
0
0
0
0
0
Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 ,
HERS Provider: CaICERTS inc. `
Report Generated at: 2016-07-20 08:35:32
CERTI9E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *HOD
Project ame: Krishnan Residence Calculation Date[Time: 08:34, Wed, Jul 20, 2016
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xmi
CFORF-01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
155
None
0.8
No
Existing
No
• Cavity/ Frame: no insul. /2x4 Top Chrd
casita add
330
.155
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck. Wood Siding/sheathing/decking
Attic Roofcasita
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Rooring: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Default prior To 1978
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R11
0.083
Over Floor Joists:.R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
"^^
• Cavity/ Frame: no insul. /2x4 Top Chrd
i
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofcasita add
Attic Roofs"+` '
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
"- T
Cavity / Frame: R-9.1 / 2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4k9%16 in s0 C1
R 38
0.025
Over Floor Joists: R-28.9 insul.
kao a
kwo`, a ?
m
IC
Inside Finish: Cavityoard
/ Frame: R-21 /� 6
_
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior`Walls
Wood Framed.,Walp
[2x6 @ 166"in. O C:
R 2�-'J
fq:066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab ex
casita
652
155
None
0.8
No
Existing
No
Covered Slab ex 2
casita add
330
.155
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required —
Registration Number: 216-Ao224228C-000000000-0000 Registration Date/Time: 2016-07-2008:41:06
CA Building Energy Efficiency Standards- 2013 Residential Compliance Report Version - CF1R-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-07-20 08:35:32
CERTIfE OF COMPLIANCE —RESIDENTIAL PERFORMANCE COMPLIANCE OD
am
Project ame: Krishnan Residence OD
aculation Date/Time: 08:34, Wed, Jul 20, 2016
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml -
CF*RF-01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar -
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
. Altered
-No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66 EF
40000-Btu/hr
0
-0
WATER HEATING - HERS VERIFICATION
01
ik'_02
03 04 05
06
07
FA6R
07
✓Point
Recirculation with
Recirculation with
Name
-Pipe Insulation
Parallel Piping' Compact Distribution -of Use
Manual Control
Sensor Control
DHW Sys 1";
Na';� " ,
n/a sNaI n/a
n/a
Na
I
Distribution
Fan
Floor Area
SPACE CONDITIONING SYSTEMS %ms *J*0 V -**go Vk 0 *Amp
01
02 7,,03
-*4 1 E
S of R Q
Vof C
FA6R
07
08
.09.
-
Heating System
Cooling System
I
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVACI
Other Heating and
Heating
Yes
1
Cooling
yes
Air Distribution
HVAC Fan
982
Existing
No
Cooling System
Component 1
Component 1
I System 1
1 1 .
I
HVAC - HEATING SYSTEMS
01
02 03
Name
Type Efficiency'
Heating Component 1
CntrlFurnace -Fuel-fired central furnace 80AFUE
Registration Number:. 216-A0224228C-000000000-0000 Registration Date/T-ime: 2016-07-2008:41:06
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-07-20 08:35:32
CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD CRF -01
Project Name: Krishnan Residence Calculation Datefrime: 08:34, Wed, Jul 20, 2016 Page 7 of 8
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xm1 -
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
_ Efficiency ,._..
.- _.
_ _a
Multi -speed
• WH Fan 1
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
'Cooling Component 1
SplitAirCond - Split air conditioning
10
12
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
'Cooling Vent Watts/CFM Number of Fans
• WH Fan 1
'Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
6.0
Attic
Attic
None
Existing
No
N/A
System 1
� specified)
raw
fication
SFam IAQVentRpt 0 � Defaui 0 Not Required
IAQ (Indoor Air Quality) FANS ? ;
01 ""'" ..w, j't";; y , ..»- 02 03. 04 05
• Name LA�Q Fran Type � IAQ Recovery Effectiveness(%) HERS Veri
COOLING VENTILATION
r
-qqw Awroe 0 - -WAt> » affi. �
U 49 W 0 '4W0 W
01
"
1 Ata . ' M
1U V L. X03 rk 04
Name
Cooling Vent CFM
'Cooling Vent Watts/CFM Number of Fans
• WH Fan 1
61
0.52459 1
IAQ (Indoor Air Quality) FANS ? ;
01 ""'" ..w, j't";; y , ..»- 02 03. 04 05
• Name LA�Q Fran Type � IAQ Recovery Effectiveness(%) HERS Veri
COOLING VENTILATION
r
-qqw Awroe 0 - -WAt> » affi. �
U 49 W 0 '4W0 W
01
"
1 Ata . ' M
1U V L. X03 rk 04
Name
Cooling Vent CFM
'Cooling Vent Watts/CFM Number of Fans
• WH Fan 1
61
0.52459 1
COOLING VENTILATION
r
-qqw Awroe 0 - -WAt> » affi. �
U 49 W 0 '4W0 W
01
"
1 Ata . ' M
1U V L. X03 rk 04
Name
Cooling Vent CFM
'Cooling Vent Watts/CFM Number of Fans
• WH Fan 1
61
0.52459 1
Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CaICERTS inc. ,
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-20 08:35:32
CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD CIRF-01
Project ame: Krishnan Residence CaTcutation Date/Time: 08:34, Wed, Jul 20, 2016 Page 8 of 8
Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
TuWi'�cei
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2016-07-20 08:41:06
Address:
CEAMERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, underthe laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Tide 24, Part 1 and Part 6 of the California Code of
Regulations. _
3. The building design features orsystem design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans grid specifications submitted to the enforcement agency for aproval with thisR building permit application.
u
Responsible Designer Name: F -f' ,!N`+ L IDIOM& I to
It
`Responsible Designer Signature:
%uiv.�cs i
Tim Scott rE"W d
-I i L
Company: e ' ti _S PDate.
Signed: *
2016-07-20
Scott Design and Title 24, Inc.
08:41:06
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-20 08:35:32
s
CJ
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Krishnan Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/20/2016
Project Address
56-985 Village Drive La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
982
Addition
330
# of Units
1
INSULATION
Construction Type
Area
Cavi(ft) Special Features Status
Roof Wood Framed Attic R11 652 Existing
Wall Wood Framed R 13 2,059 Existing
Slab Unheated Slab -on -Grade - no insulation 652 Perim = 155' Existing
Demising Wood Framed - no insulation 288 Existing
Roof Wood Framed Attic R 38 330 New
Wall Wood Framed R 21 1,169 New
Slab Unheated Slab -on -Grade - no insulation 330 Perm= 155' New
Demising Wood Framed R 13 155 New
FENESTRATION I Total Area: 314T Glazing Percentage: 31.9 % New/Altered Average U -Factor: 0.46
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Left (E) 56.0 0.610
0.59 none none . Bug Screen Existing
Right (W) 21.5 0.610
0.59 none none Bug Screen Existing
Right (W) 40.0 0.320
0.25 10.0 none Bug Screen New
Front (N) 36.0 0.320
0.25 10.0 none Bug Screen New
Left (E) 40.0 1.170
0.89 none none Bug Screen New
Right (lAq 24.0 0.320
0.25 none none Bug Screen New
Right (Nq 96.0 0.300
0.20 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 6.0
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Small Storage Gas 50
0.66 All Pipes Ins Altered
EnerqyPro 6.7 Zy EnemySoft User Number., 6712
Run Code: 2016-07-20T08:35:54 ID:
Pae 11 of 15
2013 Low -Rise Residential Mandatory Measures Summary
L_ P
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
comDliance aDDroach used. Exceptions may aDDly. Review the respective code .sectinn for mare infnrmatinn_
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of § 10-11l(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(1) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)I:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited. .
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§I50.0Q)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
4
2013 Low -Rise Residential Mandatory Measures Summary
§ I50.06)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.06)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the. installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required. by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable. requirements of UL 181, UL 181A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)l5:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§I50.0(o)lA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
r
4
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§110.40)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§I50.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ I50.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5• and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy,or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, §130.0, §130.2, §130.4, §140.7 and 141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4 140.7 and 141.0.
§150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
'
with the applicable requirements in 110.9, § 130.0, § 130.2 § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§1 10.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §110.10 b through §110.10(e).
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10 b through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
0