Loading...
BRES2016-01787&495 CALLE TAMPICO• V LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: ' Property Address: APN: Application Description: Property Zoning: Application Valuation: . BRES2016-0178 56985 VILLAGE DR 764060004 KRISHNAN / 330SF ADDITION TO EXISTING GUEST HOUSE $50,000.00 Applicant: PREST VUKSIC ARCHITECTS INC. 44530 SAN PABLO PALM DESERT, CA 92260 CfTY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of.the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 396595 Date: ` o aZ •!A Contractor: OWNER -BUILDER DECLARATION. I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to.its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760).777-7125 FAX (760)777=7011 INSPECTIONS (760) 777-7153 Date: 10/25/2016 Owner: KALLIANA KRISHNAN 737 RICHARDSON DR BRENTWOOD, CA 92253 Contractor: SJR CONSTRUCTION COMPANY INC Pb BOX 3305 PALM DESERT, CA 92261 (760)779-9399 Llc. No.: 396595 - WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by. Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in'any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the ' workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: /(7/-Z :FApplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINALPENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of.this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 'I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. i Date 1 Signature (Applicant or Agent) Date: 10/25/20.16 Application Number: BRES2016-0178 Owner: Property Address: 56985 VILLAGE DR KALLIANA KRISHNAN APN: 764060004 737 RICHARDSON DR Application Description: - KRISHNAN / 330SF ADDITION TO EXISTING GUEST HOUSE BRENTWOOD, CA 92253 Property Zoning: Application Valuation: $50,000.00 Applicant: Contractor: PREST VUKSIC ARCHITECTS INC. SJR CONSTRUCTION COMPANY INC 44530 SAN PABLO P 0 BOX 3305 PALM DESERT, CA 92260 _ PALM DESERT, CA 92261 (760)779=9399 Llc. No.' 396595 Detail; 330SF ADDITION OF TWO LIVING AREAS TO EXISTING DETACHED CASITA [ENGINEERED] THIS PERMIT DOES NOT INCLUDE REMODEL TO THE EXISTING CASITA AREA. 2013 CALIFORNIA BUILDING CODES. FINANCIAL O• DESCRIPTION' ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 10170000-42400 0 $120.83 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 Total Paid for ADDITION: $371.73 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 1 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1 $95.00 Total Paid for BLDG CITY STAFF - PER HOUR: $135.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT SERVICES 101-0000-42403 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT SERVICES PC 101-0000-426000 $12.09 Total Paid for ELECTRICAL: $36.26 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-000042403 0 $145.03 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 -0 $47.86 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402 0- $72.52 DESCRIPTION ACCOUNT QTY AMOUNT. OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $72.52 Total Paid for MECHANICAL: , $145.04 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $6.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $6.50 Bin, # City of LA Qu%uta 1 Building a Safety Division P.O. Box 1504,'78-49S Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 1` Building Permit Application and Tracking Sheet Permlt # _d ( (040, Project Address: 56-985 Village Drive Owner's Name:. Kal Krishnan A. P. Number. Address: 56-985 Village Drive Legal Description: Contractor. City, ST, zip: La Qinta, CA 92253' Telephone' Address: Proje4Description: Addition to the guest house. City, ST, Zip: , Telephone: State Lic. # : City Lic. #; Arch., Bngr., Designer. David Prest Address: 44-530 San Pablo STE 200 City., ST, Zip: Palm Desert6A92261 Telephone: .(760).779-5393 Construction Type: VB Occupancy: R-3' State Lic. #: - C-8960 Project type (circle one): Newdd'n Alter Repair Demo Name of Contact Person: Tatiana Barbuzza Sq. Ft.: 330#Stories: 1 - # Units: Telephone # of Contact Person: (760)77/-5393 Estimated value of Project 50,000.00 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES - Plan Sets Plan Cheek submitted JA Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Trus Calcs. Called Contact Person 1 Plan Check Balance Tide 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted.-. Mecharilcal Grading plan r Review, ready for correctionsrissue Electrical Subcoatactor List Called Contact Person Plumbing Grant Deed Pians picked up SALL H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '''° Review; ready for correcdons/ime Developer Impact Fee Planning Approval Called Contact Person AXP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees .Coachella Valle Unified School District.-:: y This Box For District Use Only ': : •' " 83-733 Avenue. 55; Thermal, :CA 92274 DEVELOPER FEES PA1D: ' .. (760).39_8=5909 — Fax. (760):398-1224 ;. AREA: .. ..:: - AMOUNT .. .. . . .LEVEL ONE AMOUNT:' .'. LEVEL TWO AMOUNT:' MITIGATION AMOUNT: COMM/IND.:AMOUNT: RECEIPT: ..CHECK #: ' •' • .... INITIALS ' CERTIFICATE OF COMPLIANCE (California • Education Code 17620) Project Name: he� Palms Date: " Ocfober 20, 2016 Owner's Name:.: Kal. Krishnan : - Phone No. 760-567=7310 Project Address: 56985 Village Dr.', La Quints Project Description:_ 'Residental Addition'.:: APN:. .-764-060-004 Tract #: , Lot #'s:. ; Type of Development:. " Residential.XX! Commercial Industrial Total Square Feet of Building Area: ..330 sq: ft: Certification of Appticant/Owners:..The'persoh signing certifies that the above infoiination is'correct and makes this statement under penalty of per bry and further represents that he/she:is.authorized to sign on behalf of the owner/developer: Dated:.. ..October 20;-2016.. Signature: ... ..�.' .. SCHOOL DISTRICT'S REQUIREMENTS.FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN : - ACCORDANCE WITH' ONE OF THE- FOLLOWING:. (CHICLE ONE). Education Code: Gov. Code.• Project.- :`: Agreement: Existing Not Subject to Fee .17620 65995 Approval Prior to l/1/87 Requirement;: ... ..... Note: .. .. ..... ... Number of Sq.Ft. :330 Pursuant to AB:181 any room additions or enclosures of 500 ' sq: ft. or less are exempf from developer fees'. `Any. mobile Amount.per:Sq.Ft. $0.00 homes being -relocated within :the ;same school district's ` Amount Collected . $0.00 ' jurisdiction are exempt from developer fees,; "• Building Permit:Application Completed: Yes/No By: E sa F. Esqueda, Director of Facilities and Maintenance Certificate issued by.' Laurie Howard; Secretary . Signature:.. Y( .NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT'OF FEES.. . Section 66020 of the Government Code asserted by -Assembly Bill 3081, effective january 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees; mitigation payment or other exactions ("Feed% of the 90 -day period to protest;the imposition of these, :. Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that.the 90 -day protest period' in regard to such.Fees'or:the validity thereof; commences with the payment:of:the fees or performance . any other requirements as'described in section 66020 of the Government code: Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. :As:in the latter, the 90 days'starts on the date hereof.: This Certificate of . Compliance is valid for thirty. (30) days from the date:of,issuance. Extension will tie. granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted.: :, MV:c%inydocs/`de;vfees/aertificateofcontpliancetormupdated3-2007 :. :. i ;.11!2010 ARC � � of, . shall not constitute a representation, warranty, or guarantee that such plans and specifications e,' { wit-, meed%, design, practices or zoning and building ordinances, or other governmental agency, regulations 42r The ARG shat not: be responsible for reviewing, nor shall its approval of any plans or design, be d � � .mthe standpoint of structural safety or conformance with building or other codes. By approving zsand m-cabom neither the ARC, the Members thereof, the Association, any Member thereof, their Board CF, i aV Alerabers thereof, or the Declarant assumes any liability or responsibility therefore or for any defect it t cxr�_- =6 o�n or knpovernent from such plans or specifications. As provided in the CC&R's neither the ARC, the ,,, a I of DUedors or the Association or any Members thereof not the Declarant or Developer shall b, ft� is , Owner. Occupant, or other person or entity for any damage, loss or prejudice suffered or chime a as`,t-af(l) Me aWaval or disapproval of any plans, drawings, or specifications, whether or not defective, or (' -xtan or pedbmsance of any work whether or not pursuant to the approved plans, drawings, %,are coagmation with the architectural review process is appreciated. If you have any questions, Ales at X6-5100. � d* VWAGE AT THE PALMS Architectural Review Committee Tbe 1�ertwil Tl - Ott: DW*n S BOW V� ; The Management Trust OWNER INSPIRED. CHALLENGE ACCEPTED, VILLAGE AT THE PALMS HOMEOWNERS ASSOCIATION RECEIVED : � t... JUN 2 4 2016 - XILEY WAY #302 ` CITY OF LA QUINTA COMMUNITY DEVELOPMENT ' •:^ f' for, %,9W VILLAGE DRIVE ' f?cr�eovrr�- • vb�E ,�fttect=d ReeiOs Committee for VILLAGE AT THE PALMS has reviewed and APPROVED your architectural t?ae 0.tion oi' desert landscape and removal of existing per the plans submitted. ARC � � of, . shall not constitute a representation, warranty, or guarantee that such plans and specifications e,' { wit-, meed%, design, practices or zoning and building ordinances, or other governmental agency, regulations 42r The ARG shat not: be responsible for reviewing, nor shall its approval of any plans or design, be d � � .mthe standpoint of structural safety or conformance with building or other codes. By approving zsand m-cabom neither the ARC, the Members thereof, the Association, any Member thereof, their Board CF, i aV Alerabers thereof, or the Declarant assumes any liability or responsibility therefore or for any defect it t cxr�_- =6 o�n or knpovernent from such plans or specifications. As provided in the CC&R's neither the ARC, the ,,, a I of DUedors or the Association or any Members thereof not the Declarant or Developer shall b, ft� is , Owner. Occupant, or other person or entity for any damage, loss or prejudice suffered or chime a as`,t-af(l) Me aWaval or disapproval of any plans, drawings, or specifications, whether or not defective, or (' -xtan or pedbmsance of any work whether or not pursuant to the approved plans, drawings, %,are coagmation with the architectural review process is appreciated. If you have any questions, Ales at X6-5100. � d* VWAGE AT THE PALMS Architectural Review Committee Tbe 1�ertwil Tl - Ott: DW*n S BOW V� ; YOUNG ro@a a o� o D ENGINERING E a w: Letter of Transmittal' To: City of La Quinta Today's Date 7=7=2016 ~� t "-78-495 Calle'Tampico - City Due-Date:7-11-2016 ^ La Qulnia,• CA 92253 - ' . Project'Address:'- 56985 VILLAGE DR '� ,Attn: 'Ramses Sevilla Plan Check # BRES20'16-0"178; < ;Submittal *. ®; 15� ❑ 4`h �i a;, 2nd ❑ 5th ',3rd r❑ -Other. , We are forwarding. ® By Messenger ❑ By Mail (Fed Ex or.UPS) `' ❑ YourPickup ' R'• < ' Includes: Descnptio,ns , • Includes # Of " Descriptions 4 ,Copies: - < Structural Plans + ❑ R .°Revised Struct. Plans' StructuraF Calculations ` - ' ❑ Revised Structs Calcs� < ❑ ~r Truss Calcs :�.. �= . �- y . ❑ Revised Truss:Calcs r ❑: '. d ' Soils`Report Update`,.. -Revised Soils Report', '❑. �. Structural P/C Comments '' O�• t R Approved Structural_Plans :. + ` 'Redlined Structural•Plans _ ^❑ Y 4 `_ Approved Structural Calcis R El ;Redlined StrLickiral Calcs .' '- ` ❑ s z ~' : Approved.Truss Calcs < ` . ,+ '; �' i' Rbdlined;Truss Calcs _ t ,�� Approved Soils Report ' + - ❑ Redlined'Soils_ Reports ❑ :k Other,.`,,*' Comments.. '': Structural content is'approvable. : .Transit Pet. Admin Time - .25'HR :4 F Structural- Engineer/Principal Review Tirrie' = O HR' - R. 'Plan Review. Engineer. Time = 1 HR' rom Thisf Mate'ri�aI :Sent ❑`; Your files ® PerYourRequest Your: eview, Approval �' ;.. ❑'; Checking, Y. °❑ At the 'request of ` # Other: ❑ F By BrQnz,Yourig 'Office- ® `(760).,772-51.07 F r r • Othe❑ ', ' • �' if .. C, 3 <�F r ' �'- f • f y , 1 - R 4 lM1 k 4 " < Plan SubmNW Dr 'Job Sde Addie s ` r' (h�unwra.Nwi Building Permit Number: Project Description: Small Room Addition Exampt: O (Materials may contain.hazardous wastes and are not iwbject.to recycling provisions) Construction Debris Management Plan 10/24/2016 56985 Village Drive Krishnan 56985 Village Drive La Quinta, CA. 92253 :* ProJeedWanagerb�Nwnd Steve Ruffolo Projd&VManagers3Phone Number 760-567-7310 ProJecHManegera'Envail Address davldDCdlrxestvuksicaarchitads.com Builder /Contractor, SJR COnStnJCtlOn r ANumber `street or PO t3oz 49291 Mariposa Dr crit' -*state Postal Code Palm Desert, CA. 92260 Prolect`Square Footepe Approx. 330 square feet 'q City Approval By-R4d%—DELA. t6x Date of City Approval, b%2k Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse* 'Describe Items Tons 172-51 Not recyclable Recyclable Recyclable Recyclable Recyclable Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons Totals: Rec cle Trash Projected : 1.7 1 1.31. 11 FS7.19% 1 understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 60% of the Jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or reuse, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is Issued in the name.of the property owner(s) and shall remain their property throughout the construction and/or demolition project A contractor serving as agent of the owner may obtain a DNIP for the owner. However, the DMP Is still Issued in the name of the propertyowner(s) and.the owner retains legal responalblilty. for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be keptiefonned of the diversion progress through bl-monthly reports. if self -hauling,. all -refuse material from this project eke must be taken to an approved recycler or transfer Owrier /Developer / Project Manager / Superintendent Date BUILDING ENERGY ANALYSIS REPORT i A PROJECT: Krishnan Residence, 56-985 Village Drive La Quinta; CA 92253 ' Project Designer: F Prest Vuksic Architects 44-530 San Pablo STE 200 Palm. Desert, CA 92261 . (760) 779-5393 Report Prepared by: Jon ,Scott }� Scott Design and Title 24, Inc; 74-818 Velie Way, STE 8 . Palm Desert, CA 92260 , (760) 702-5406 �DG �j ED CITY OF L.A QUINTA �u� � � Nib BUILDING & SAFETY DEPTH b Number: QUlNTA ROVED. MU I v 0 ,60PMONT '0M FOR ONSTRUGTION tt 1� Date:. BY _ D ?-0I7/29L201B. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This developed by EnergySoft, LLC program —www.energysoft.com: EnergyPro 6.7 bX EnergySoft User Number., 6712 ID: is � � a �. - .� .. CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOOD Project ame: Krishnan Residence Calculation Date/Time: 08:34, Wed, Jul 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml COORF-01 Page 1 of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Krishnan Residence 04 05 02 Calculation Description Title 24 Analysis 08 - 03 Project Location 56-985 Village Drive Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 982 15 Number of Zones 2 16 Slab Area (ft2) 982 17 Number of Stories 1 18 Addition Cond. Floor Area 330 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 330 21 Glazing Percentage (%) 31.9% COMPLIANCE RESULTS 01 Building Complies viitl Computer,`Performbance 02- This building incorpoiates'featur ,that require field1est ngsand/or v' eerificat��ib�ri,by alcertifi d+HERS Yf5ter unde the supervision of a CECapproved HERS provider. 03 This building incorporates oneor4�more Special Features ihhown beiow � ' 0 Registration Number: 216-A0224228C-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-07-20 08:41:06 Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-20 08:35:32 , ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 13.19 10.19 3.00 22.7% Space Cooling 351.51 348.57 2.94 0.8% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 19.85 16.95 .2.90 14.6% - Photovoltaic Offset - - —_ - — - - 0.00 _ _ . __. _ _ . _ 0.00 Compliance Energy Total 384.55 375.71 8.84 2.3% Registration Number: 216-A0224228C-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-07-20 08:41:06 Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-20 08:35:32 , CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OHOD Project ame: Krishnan Residence Calculation Date/Time: 08:34, Wed, Jul 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. ' • Window overhangs and/or fins CF•RF-01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: High Quality Insulation Installation (QII) Cooling System Verifications: • — None — HVAC Distribution System Verifications: t • — None — Domestic Hot Water System Verifications: • — None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use.components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system.? '' Refe`r�ence Energy Usenergy; Design Ratingf Margin Percent Improvement Total Energy (kTDV/f2-yr)* /'_ ' 451.17 z s, � ;,442 33 " � 8.84 2.0% includes calculated Appliances and Miscellaneous Energy Use (AMEU BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Krishnan Residence 982 1 2 2 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 casita Conditioned HVAC1 652 9 DHW Sys 1 casita add Conditioned HVAC1 330 9 DHW Sys 1 Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 -Report,Generated at: 2016-07-20 08:35:32 i CERTI#E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Krishnan Residence Ca culation Date/Time: 08:34, Wed, Jul 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Krishnan -PV 16.xml CF*RF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition N Wall ex casita R-13 Wall 0 Front 455 0 90 Existing No E Wall ex casita R-13 Wall - 90 Left 633 56 90 Existing No S Wall ex casita R-13 Wall 180 Back - 455 0 90 Existing No W Wall ex casita R-13 Wall 270 Right 633 61.5 90 Existing No Roof casita Default prior To 1978 652 Existing No N Wall casita add R-21 Wall (W.21.2x6.16) 0 Front 455 36 90 New N/A E Wall casita add R-21 Wall (W.21.24.16) 90 Left - 455 40 90 New N/A W Wall casita add R-21 Wall (W.21.24.16) 270 Right 455 120 90 New N/A Roof 2 casita'add R-38 Roof Attic 330 New N/A ATTIC 01 02� ` 03 r04 1 0;5 � 06 _ 07 08 09 10 Radiant Statu Verified Existing Name%tatd r> .Constructionype %�t ,Roof Rise mRoof Reflectance Roof�Em��ttance Barrier Cool Roof s Condition Attic casita ` Attic Roofta Ventilated 3 E o.1 a. 0-x_85 No No Ex9ti No ,> n Attic casita add Attic Roofcasita add Ventilated 3 0.1 0.85 No No New No Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-20 08:35:32 CERT-�TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE•HOD CIORF-01 Project Rame: Krishnan Residence Calculation Date/Time: 08:34, Wed, Jul 20, 2016 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml WINDOWS 01 02 03 - 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) - Multiplie Height (ft) r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 8x5 E Wall ex (Left -90) - - 1 40.0 0.61 0.59 Insect Screen (default) Existing No ex 2x2 E Wall ex (Left -90) - - 1 4.0 0.61 0.59 Insect Screen (default) Existing No ex 2x2 2 E Wall ex (Left -90) - - 1 4.0 0.61 0.59 Insect Screen (default) Existing No ex 2x2 3 E Wall ex (Left -90) - - 1 4.0 0.61 0.59 Insect Screen (default) Existing No ex 2x2 4 E Wall ex (Left -90) - - 1 4.0 0.61 0.59 Insect Screen (default) Existing No ex 4.3x5 W Wall ex (Right -270) - - 1 21.5 0.61 0.59 Insect Screen (default) Existing No 1 5x8 W Wall ex (Right -270) 5.0 8.0 1 40.0 0.32 0.25 Insect Screen (default) New N/A D 4.5x8 N Wall (Front -0) 4.5 8.0 1 36.0 0.32 0.25 Insect Screen (default) New N/A A 3.4x5 new hist E Wall (Left -90) - - 1 17.0 1.17 0.89 Insect Screen (default) New N/A Al 3.4x5 new hist . E Wall (Left -90) �. - - 1 6.0 1.17 0.89 Insect Screen (default) New N/A A2 3.4x5 new hist E Wall (Left -90), a"-"' - - 1 17.0 1.17 0.89 1 Insect Screen (default) New N/A E 3x8 1`W Wall (Right -270) = Tj- 'A 24`.0 0.32 0,�5� Insect Screen (default) New N/A C 6x8 W Wall .(Righi-270)-° - 1 �48)0� 0 3U i 20 Insect Screen (default) New N/A B 6x8 `.'W Wall (Right2270) - - 1 48.0 0.30 0.20 Insect Screen (default) New N/A OVERHANGS AND FINS 01 02 03 04 OS 08 09. 10 11 12 13 14 OverhangLeft Fin Right Fin Window Depth Dist Up Left Extent Right Extent =Ht.*Depth op Up DistL Bot Up Depth Top Up Dist R Bot Up 15x8 10 0.1 10 100 0 0 0 0 0 0 D 4.5x8 100.1 10 100 0 0 0 0 0 0 Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 , HERS Provider: CaICERTS inc. ` Report Generated at: 2016-07-20 08:35:32 CERTI9E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *HOD Project ame: Krishnan Residence Calculation Date[Time: 08:34, Wed, Jul 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xmi CFORF-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 155 None 0.8 No Existing No • Cavity/ Frame: no insul. /2x4 Top Chrd casita add 330 .155 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck. Wood Siding/sheathing/decking Attic Roofcasita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Rooring: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default prior To 1978 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R11 0.083 Over Floor Joists:.R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking "^^ • Cavity/ Frame: no insul. /2x4 Top Chrd i 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofcasita add Attic Roofs"+` ' Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Ceilings (below "- T Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4k9%16 in s0 C1 R 38 0.025 Over Floor Joists: R-28.9 insul. kao a kwo`, a ? m IC Inside Finish: Cavityoard / Frame: R-21 /� 6 _ • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior`Walls Wood Framed.,Walp [2x6 @ 166"in. O C: R 2�-'J fq:066 Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab ex casita 652 155 None 0.8 No Existing No Covered Slab ex 2 casita add 330 .155 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required — Registration Number: 216-Ao224228C-000000000-0000 Registration Date/Time: 2016-07-2008:41:06 CA Building Energy Efficiency Standards- 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-20 08:35:32 CERTIfE OF COMPLIANCE —RESIDENTIAL PERFORMANCE COMPLIANCE OD am Project ame: Krishnan Residence OD aculation Date/Time: 08:34, Wed, Jul 20, 2016 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml - CF*RF-01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar - Fraction N Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual . Altered -No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 EF 40000-Btu/hr 0 -0 WATER HEATING - HERS VERIFICATION 01 ik'_02 03 04 05 06 07 FA6R 07 ✓Point Recirculation with Recirculation with Name -Pipe Insulation Parallel Piping' Compact Distribution -of Use Manual Control Sensor Control DHW Sys 1"; Na';� " , n/a sNaI n/a n/a Na I Distribution Fan Floor Area SPACE CONDITIONING SYSTEMS %ms *J*0 V -**go Vk 0 *Amp 01 02 7,,03 -*4 1 E S of R Q Vof C FA6R 07 08 .09. - Heating System Cooling System I Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVACI Other Heating and Heating Yes 1 Cooling yes Air Distribution HVAC Fan 982 Existing No Cooling System Component 1 Component 1 I System 1 1 1 . I HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency' Heating Component 1 CntrlFurnace -Fuel-fired central furnace 80AFUE Registration Number:. 216-A0224228C-000000000-0000 Registration Date/T-ime: 2016-07-2008:41:06 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-07-20 08:35:32 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD CRF -01 Project Name: Krishnan Residence Calculation Datefrime: 08:34, Wed, Jul 20, 2016 Page 7 of 8 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xm1 - HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 _ Efficiency ,._.. .- _. _ _a Multi -speed • WH Fan 1 Name System Type EER SEER Zonally Controlled Compressor HERS Verification 'Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A Location system Status Condition Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 'Cooling Vent Watts/CFM Number of Fans • WH Fan 1 'Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 6.0 Attic Attic None Existing No N/A System 1 � specified) raw fication SFam IAQVentRpt 0 � Defaui 0 Not Required IAQ (Indoor Air Quality) FANS ? ; 01 ""'" ..w, j't";; y , ..»- 02 03. 04 05 • Name LA�Q Fran Type � IAQ Recovery Effectiveness(%) HERS Veri COOLING VENTILATION r -qqw Awroe 0 - -WAt> » affi. � U 49 W 0 '4W0 W 01 " 1 Ata . ' M 1U V L. X03 rk 04 Name Cooling Vent CFM 'Cooling Vent Watts/CFM Number of Fans • WH Fan 1 61 0.52459 1 IAQ (Indoor Air Quality) FANS ? ; 01 ""'" ..w, j't";; y , ..»- 02 03. 04 05 • Name LA�Q Fran Type � IAQ Recovery Effectiveness(%) HERS Veri COOLING VENTILATION r -qqw Awroe 0 - -WAt> » affi. � U 49 W 0 '4W0 W 01 " 1 Ata . ' M 1U V L. X03 rk 04 Name Cooling Vent CFM 'Cooling Vent Watts/CFM Number of Fans • WH Fan 1 61 0.52459 1 COOLING VENTILATION r -qqw Awroe 0 - -WAt> » affi. � U 49 W 0 '4W0 W 01 " 1 Ata . ' M 1U V L. X03 rk 04 Name Cooling Vent CFM 'Cooling Vent Watts/CFM Number of Fans • WH Fan 1 61 0.52459 1 Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CaICERTS inc. , CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-20 08:35:32 CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD CIRF-01 Project ame: Krishnan Residence CaTcutation Date/Time: 08:34, Wed, Jul 20, 2016 Page 8 of 8 Calculation Description: Title 24 Analysis Input File Name: Krishnan-PV-16.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: TuWi'�cei Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2016-07-20 08:41:06 Address: CEAMERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, underthe laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Tide 24, Part 1 and Part 6 of the California Code of Regulations. _ 3. The building design features orsystem design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans grid specifications submitted to the enforcement agency for aproval with thisR building permit application. u Responsible Designer Name: F -f' ,!N`+ L IDIOM& I to It `Responsible Designer Signature: %uiv.�cs i Tim Scott rE"W d -I i L Company: e ' ti _S PDate. Signed: * 2016-07-20 Scott Design and Title 24, Inc. 08:41:06 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0224228C-000000000-0000 Registration Date/Time: 2016-07-20 08:41:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-07-20 08:35:32 s CJ RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Krishnan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/20/2016 Project Address 56-985 Village Drive La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 982 Addition 330 # of Units 1 INSULATION Construction Type Area Cavi(ft) Special Features Status Roof Wood Framed Attic R11 652 Existing Wall Wood Framed R 13 2,059 Existing Slab Unheated Slab -on -Grade - no insulation 652 Perim = 155' Existing Demising Wood Framed - no insulation 288 Existing Roof Wood Framed Attic R 38 330 New Wall Wood Framed R 21 1,169 New Slab Unheated Slab -on -Grade - no insulation 330 Perm= 155' New Demising Wood Framed R 13 155 New FENESTRATION I Total Area: 314T Glazing Percentage: 31.9 % New/Altered Average U -Factor: 0.46 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Left (E) 56.0 0.610 0.59 none none . Bug Screen Existing Right (W) 21.5 0.610 0.59 none none Bug Screen Existing Right (W) 40.0 0.320 0.25 10.0 none Bug Screen New Front (N) 36.0 0.320 0.25 10.0 none Bug Screen New Left (E) 40.0 1.170 0.89 none none Bug Screen New Right (lAq 24.0 0.320 0.25 none none Bug Screen New Right (Nq 96.0 0.300 0.20 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic 6.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 50 0.66 All Pipes Ins Altered EnerqyPro 6.7 Zy EnemySoft User Number., 6712 Run Code: 2016-07-20T08:35:54 ID: Pae 11 of 15 2013 Low -Rise Residential Mandatory Measures Summary L_ P NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the comDliance aDDroach used. Exceptions may aDDly. Review the respective code .sectinn for mare infnrmatinn_ Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of § 10-11l(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(1) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)I: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. . Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §I50.0Q)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 2013 Low -Rise Residential Mandatory Measures Summary § I50.06)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.06)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the. installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required. by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable. requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)l5: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)lA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. r 4 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines or built-up connections for future solar heating. §110.40)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)IC: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer §150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § I50.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5• and all other requirements in § 150.0(k)2. § 150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only §150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy,or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and §150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, §130.0, §130.2, §130.4, §140.7 and 141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4 140.7 and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply ' with the applicable requirements in 110.9, § 130.0, § 130.2 § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §1 10.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §110.10 b through §110.10(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10 b through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 0