07-1368 (SFD)44P.O. BOX .1504 "
78-495 CALLE TAMPICO
ta; _LA QUINTA;; CALIFORNIA 92253 BUILDING & SAFETY. DEPARTMENT
°"'' BUILDING PERMIT
.'
Application Number:
Property Address:
APN:
Application description:
'Property Zoning:
Application valuation:
Applicant:
07-00001368
56145 -VILLAGE DR
764 -030 -014 -
DWELLING - SINGLE FAMILY•DETACHEO
LOW DENSITY RESIDENTIAL
344838
Architect or Engineer
------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under 'provisions of Chapter 9 (commencing with-
- Section 7000) of Division3 of the Bu 'ness and Professionals Code, and my License is in full force and effect. ,
License Class: B •i se No.:�S638�
Date_ ;-Contractor:RL
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason ISec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the -
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section.7000) of Division of the Business and Professions Code) or
that he or she is exempt,therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit. subjects the applicant to a civil penalty of not more than fiVehundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
` Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her awn employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within '
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). -
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec:
7044, Business and- Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed.
pursuant to the Contractors' State License Law.). _
) lam exempt under Sec. , B.&P.C. for this reason -
Date: Owner:
CONSTRUCTION LENDING AGENCY -
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.). -
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
CHUCK & SHERRI LAYTON
56-145 VILLAGE DRIVE.
LA QUINTA, CA 92253'
Contractor:
AUSTIN DESERT HOMES -
78535 AVENIDA ULTIMO''
LA QUINTA, CA 92.253
(760)200-7605
Lic. No.: 865638
VOICE (760) 777=7012.
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
D/19
CIfTI.
Frn,oFl 4 a,:...
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I. have and will•maintain a certificate of consent to self -insure for workers' compensation; as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is '
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier EXEMPT Policy Number EXEMPT
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I sh Id become suFb'o the workers' compensation provisions of Section
3700 of the Labor C , I shall forthc ply w` e-provlMons. -
^Date: 1� Applicant: 1 'Ilk -
��--_
WARNING: FAILURE TO SECURE -WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS 15100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each.person upon whose behalf this application is made, each person at whose request and for
-
whose benefit work is performed under or pursuant to any permit issued as a result of this application, ,
the owner, and the applicant, each agrees to, and shall defend, indemnify acid hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced .
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. -
I.certify that I have read this application and state that the above information is correct. I.agree to comply with all
,city and county ordinances and state laws relating to b ilding constructi , and here uthorize representatives
of this county to enter upon the above-mentioned prop y for inspecti np poses.
Date: iZaa-� ""Signature (Applicant or•Agentl:
LQPERMIT - ,
Application Number .
. . . . 07-00001368
---: Structure Information
3;897SF DWELLING/V-NR%RES-3/CLASS
A -FR - ---
a'
Other struct info
CODE EDITION 2001/2005
Win+
# BEDROOMS
3.00
FIRE SPRINKLERS NO
'GARAGE SQ FTG
1074.00
PATIO SQ FTG.
670.00
NUMBER OF UNITS
1.00
1ST FLOOR SQUARE FOOTAGE
3897.00^:•
Permit . .
BUILDING PERMIT
•
Additional des'c .
Permit Fee
1497.00 Plan Check Fee
973.05•
Issue.Date . . . .
Valuation
344838' -
Expiration Date
6/16/08
Qty Unit Charge
Per
Extension
BASE FEE
639.50
�. 245.00 3.5000
THOU BLDG 100,001-500,000.
857.50
Permit . .
ELEC-NEW RESIDENTIAL
Additional. desc .
Permit Fee
179.80 Plan Check Fee
44.95
Issue Date
Valuation
0
Expiration Date
6/16/08
-
Qty Unit Charge
Per
Extension
BASE FEE
_ 15.00
3897.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY.
136.40
670.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
13.40
1.00 15.0000
EA ELEC TEMPORARY POWER POLE
15.00
Permit
GRADING PERMIT
-
Additional desc
,
Permit Fee
15.00 Plan Check Fee
.00
Issue Date,
Valuation
0
Expiration Date
6/16/08
Qty Unit Charge
Per
Extension
---------------------------------------
BASE FEE
-----------------.-------------
15.00
-------
Permit
MECHANICAL
4
"
Additional desc
Permit Fee . . . .
125.00 Plan Check Fee
31.25 -
LQPERMIT - ,
LQPERMIT -
a
:.Application Number 07-00001368
Permit . . <.. MECHANICAL,
Issue Date: Valuation
0
Expiration Date 6/16/08
Qty Unit -Charge Per
Extension
BASE -FEE
15.00
2.00 9.0000 EA MECH•FURNACE <=100K
18.00
1.00 4.5000 EA MECH VENT INST/ DUCT ALT'
4.50
1.00 9.0000 EA MECH APPL REP/ALT/ADD
9.00
�- 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU
33.00
6.00 6.5000 EA MECH'VEN'T PAN
39.00
1.00 6.5000 EA MECH 'EXHAUST HOOD
6.50
Permit . . . PLUMBING
Additional desc -
Permit Fee 207.00 Plan Check Fee
51.75
'
Issue Date . . . .- Valuation . . . .
0
Expiration -Date 6/16/08
- Qty Unit Charge. Per
Extension
BASE FEE
15.00
21.00 6.0000 EA PLB FIXTURE
126.00
1.00 15.0000 EA PLB BUILDING SEWER
15.00•
2.00 7.5000 EA PLB WATER HEATER/VENT
15.00
1.00, 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
12.00 .7500 EA PLB GAS PIPE >=5
9.00
1.00 15.0000 -EA- PLB GAS METER
15.00
-
----------------------------------------------------------------------------
Special Notes and Comments
'
3,897SF DWELLING/V_NR/RES-3/CLASS A -FR.
t THIS PERMIT DOES NOT INCLUDE
BLOCKWALLS,-POOL AND SPA, OR.DRIVEWAY
APPROACH. 2001 CBC, CPC, CMC, 2004 CEC,
2005 ENERGY. July 11, 2007 3:57:19 PM'.
AORTEGA -
-
-7----------------------------------------
Other Fees . . . . . ART IN PUBLIC PLACES -RES
362.09.
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
995.00
ENERGY REVIEW FEE
97.31
DIF FIRE PROTECTION -RES-
140.00
GRADING PLAN CHECK FEE
15.00
DIF LIBRARIES - RES
355.00
DIF PARK-MAINT FAC - RES
22.00
DIF PARKS/REC - RES,
892.00
STRONG MOTION.(SMI) - RES
34.48
LQPERMIT -
Application Number . . . . . 07-00001368
----------------------------------------------------------------------------
Other Fees . . . . . . . . . DIF STREET MAINT FAC -RES 67.00
DIF TRANSPORTATION - RES 1930.00
Fee summary Charged
Permit Fee Total 2023.80
Plan Check Total 1101.00
Other Fee Total 4983.88
Grand Total 8108.68
LQPERMIT
Paid Credited Due
.00 .00 2023.80
750.00 .00 351.00
.00 .00 4983.88
750.00 .00 7358.68
Coachella Valley Unified School District ` This Box For District Use .only
.83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID
(760) 398-5909 — Fax (760) 398-1224 "
AREA: ' . -
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
- MITIGATION AMOUNT:
COMM IND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Residence is at the Palms Date: December 17,n2007 ,.
Owner's Name: Chuck and Sherri Layton Phone leo. 200-7605
Project Address: 56-145 Village Drive La Quinta; CA
Project Description: 1 SFD
APN: 764-030-014 Tract #: Lot #'s:
Type of Development:. ' . Residential !XX. Commercial Industrial
Total Square Feet of Building Area: 3,897 sq. ft.
Certification of Applicant/Owners: The person signingkeffies thJthbo a informati i correct and makes this statement under
penalty of perjury and further represents that he/she is authto beh if of the /developer.
Dated: December 17,n 2007 Signature: _
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
-ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code: -Project Agreement Existing Not Subject to Fee.
17620 '' 65995 , . Approval Prior to 1/1/87 Requirement
N^M I
Number of Sq.Ft. 3,897
Amount per Sq.Ft. $3.48
Amount Collected $13,561.56
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt.; Business Services
Certificate issued by: Elvira Mattson, Secretary III Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES y
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
MV:c/mydocs/devfees/certrticate'ofcompliance form tablesTO USE.doc 1/16/03 T.
RECORDING REQUESTED BY:
STEWAR —E COMPANY
AND WHEN RECORDED, MAIL TO:,
Charles C. Layton
56125 Village Drive
La Quinta, CA 92253
DOC tB 2005-0443986
06/03/2005 08:00A Fee:27.00
Page 1 of 1 Doc T Tax Paid
Recorded in Official Records
County of Riverside
Larry W.• Ward
Assessor, County Clerk & Recorder
� • � 111111111111111111 IIIII IIIILIIIII 111111 III IIIiI 1111 illl
M
TUPA E a... DA PCOR
NOCOR S—MF
GRANT DEED
t TJ
LA
ASSESSOR'S PARCEL NO.: 764-030-014-9 The undersigned Grantor(s) declare that the DOCUMENT TRANSFER TAX IS.
TITLE ORDER NO.: 507282404 $412 * 50 County
ESCROW NO.: 24209-003 XX cmputed on the fiill value of the interest of property conveyed, cr
r computed on the full value less the value of liens or encumbrances remaining thereon
at the time of sale.
OR transfer is EXEMPT from tax for the following reason:
'FORA VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Richard A. Vershure and Maureen Vershure,
Husband and Wife as Joint Tenants
hereby GRANT(S) to Charles C. Layton and Sherri LaytonHusband and Wife as Community Property.
all that real property situated in the Cit} -e€ , County of Riverside, State of CA, described as: Lot 34 of Tract No. 28983 as
shown by map on file in book 285, pages 76 through 82 of Maps, Records of Riverside County, California. -
Dated March 14, 2005
State oferaia }
County of
On ; c`6 auLf�, Before me' i ne , e. Notary Public Rlrfwd A. Vershure
Personally appeared _
•-
- Maureen Vershure
Personally known to me (or provided to me on the basis of satisfactory
evidence) to be the person(i) whose name(s) is/are subscribed to the
within instrument and acknowledged to me that he/she/they executed the
same in his/her/their authorized capacity(ies), and that by his/her/their
signature(s) on the instrument the person(s) or the entity upon behalf of
which the person(s) acted, executed the instrument.s...i.......►
LINDA W. HERBST
NOTARY PUBLIC • STATE OF NEW YORK
WITNESS hand and official seal 01 HE5088817
r WESTCHESTER COUNTY
My Commission Expires November 24, 2005
I`
i tore
L ' (This aredfor official notary seal)
MAIL TAX STATEMENTS TO: re,
Charles C. Layton `•
56125 Village Drive -
La Quinta, CA 92253
.
Certificate of Occupancy
=�
OF'T�ti Building & Safety Department
'
This Certificate is issued pursuant to the requirements of .Section 109 of the California Building
x
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating. building
a
construction and/or use.
BUILDING ADDRESS: 56-145 VILLAGE DR
Use classification: SFD _ Building' Permit No7-1368
Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL
Owner of Building: LAYTON Address: 56145 VILLAGE DR
s
City, ST, ZIP: LA QUINTA CA 9223
By: KIRK KIRKLAND
&'i"'L Date: 4-23-09
Building Officia
L'
POST IN A CONSPICUOUS PLACE
t-
TITLE 24 REPORT
Title -24 Report for:
THE LAYTON RESIDENCE
Lot No.34 Village Drive - A. P. N:.764-030-014
La Quinta, Ca 92253
k r'
Project Designer::
TELLEZ DESIGN AND ASSOCIATES
760.989.3457. K
Re ort Pre ared :xB
S.L.O.
Santiago Lopez-Ocampo`
.,
P'.O. Box 10,18
5 La Quinta, CA 92247,, y -
.. (760) 485-892.
JUN
bye_
CITY OF•LA QUINTA Job Number: �.
BUILDING & SAFETY DEPT.
APPROVE® Ig042307. ti
co�
3
FOR CONSTRUiCTION e.z
Date: ,4
DATE BY ,
6/13/2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program- has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards:,
This program developed by EnergySoft, LLC - www.energysoft.com. L. `
EnergyPro 4:3 by EnergySoft Job Number: lg042307 User Number: 6732
r
'�\
r
I ... - -
- - a �y
�4
., - -
�
C
. "i1'
j� ,.. •
� 3
� _
Certificate Of Compliance: Residential
Total Conditioned Floor Area:
(Part 1 of 4) CF -1 R
THE I AYTON RESIDENCE
Project Title
(N) 0 deg
Raised Floor Area:
Natural Gas
6/13/2007
Date
I of No34 Village nroyp
- A P N- 764-030-014
La
Project Address
Building Permit #
Santiago I one7-0r;imoo
'
(76 0) 485-8927
Documen action Author
Telephone
Plan c,eck/Date
EneravPro
Compli'�i ce Method
CA
Climate Zone 15
Climate Zone
Field Check/Date
TDV
Standard
Proposed Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.16
1.95
0.21
Space Cooling
65.09
57.27
7.82
Fans
9.26
8.14
1.12
Domestic Hot Water
6.59
7.38
-0.80
Pumps
0.00
0.00
0.00
Totals
83.09
74.74
8.35
Building Type:
n Standard:
Y Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
10.0%
❑ Addition
Total Conditioned Floor Area:
❑ Existing + Add/Alt
Existing Floor Area:
(N) 0 deg
Raised Floor Area:
Natural Gas
Slab on Grade Area:
Fenestration: Average Ceiling Height:
Area: 837 ft2 Avg. U: 0.39 Number of Dwelling Units:
Ratio: 21.5% Avg. SHGC: 0.37 Number of Stories:
BUILDING ZONE INFORMATION # of Thermostat
Zone Name Floor Area Volume Units Zone Type Type
HVA • Systpm - Zone 1 149 17 136 n 37 Conditioned— Spthark
HVAC: S gtem -Zone 2 2 469 344.566 0_63 Cnnditinned Setback
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Rnnf Wnnd 1r47A 0 Q9.5 X38 -n n n — n
Wall Wood 38 n n69 R-21 R -n n 31.9; gQ
Wall— Wood 232 0.069 R-21 R -n n n gn
nnnr Nnne 24 _J0 500 Nnne R_0 0 _� 90
Wall Wnnd 157 _Q Q69 R21R-Q n 1Af) gn
Wall Wood 628 _Q Q6c) X91 R -Q Q —270 qQ
Rnnf Wnnd 2 469 n 025 R -IA R_0 0 _n _ 1 A
Wall Wnnd 69 n n69_ R_21 R_n a 31f; gQ
wall— Wnnd 69 0 069 R_91 R-0.0 c.0 gn
Wall Wood 736 0 069 R_21 R-0 0 n gn
nnnr Nnne 32 0 50Q NnnP R-Qn n An
Wall Wnnd A96 n n69 R_21 R_n 0 90 gn
Wall Wnnd 728 Q 089 B21R-0 0_-180 go
nnnr None 24 0 500 None R-0 0 180 90
Wall Wood 104 0 069 R_21 R-0 0 270 9
3,897 ft2
n/a ft2
0 ft2
3,897 ft2
13.3 ft
1.00
Vent
Hgt. Area
—2 n/
n/a
Gains Condition
Y / N Status JA IV Reference Location / Comments
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: lg042307 Page:3 of 13 1
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Window
Condition
Overhang
Left Fit Right Fin
#
THE LAYTON
RESIDENCE
6/13/2007
Project Title
Len
Hgt LExt
Date
1
FENESTRATION SURFACES
0.76
5.0
4.0
2.0
True Cond.
Location/
# Type
Bug Screen
0.76
Area LI -Factor" SHGC2 Azm. Tilt Stat. Glazing Type
Comments
Cjjf Window
Right -(NW
10.0
_20 0 n Iq NFRC_-OX MERG 31 F; _,q0_ New Milnard Classic nw-E Vinyl
7nnP 1
42 Window
Front
(N)
25.0 0.390 NFRC 0_37 NFRC 0 90 New Milgard Classic Low -E Vinyl
Zone 1
F3� Window
Rear
(S)
2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 1
c4i Window
Rear
(S)
2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 1
c5s Window
Rear
(S)
2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 1
i65 Window
Rear
(S)
2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 1
�Z� Window
Rear
(Sl_
2.2 X99 NFRC _0_U NFRC 180 90 New Milgard Classic Low -E V*nyL
Zone 1
�8 Window
Rear
(S)
48.0 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
_ Zone 1
L Window
Rear
(S)
48.0 0.390 NFRQ 0.37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 1
1Q+�Window
Right
(W)
. 15.0 0.39 NFRQ -0,37 NFRC 270 90 New Milgard Classic Low -E Vinyl
Zone 1
C11' Window
Right
(W)
15.0 0_390 NFRC 0_37 NFRC 270 90 New Milgard Classic Low -E Vinyl
Zone 1
q-2 Window
Right
(W)
2.2 0.390 NFRC 0_37 NFRC 270 90 New Milgard Classic Low -E Vinyl
Zone 1
Window
Right
(W)
2.2 039 NFRC _QX NFRQ 970 q.Q New Milnard Classic Low -E Viny
7one 1
' 1i Window
Right
(W)
21.3 0.390 NFRC 0_37 NFRC 270 90 New Milgard Classic Low -E Viny
Zone 1
4:5 -Window
Right
(W)
15.0 0.390 NFRC 0_37 NFRC 270 90 New Milqard Classic Low -E Viny
Zone 1
Window
Right
(W)
25.0 0.390 NFRC 0_37 NFRC 270 90 New Milgard Classic Low -E Viny
Zone 1
c1_73Window
Right
(W)
21.3 0.390 NFRC 0_37 NFRr; 270 90 New Milgard Classic Low -E Viny
Zone 1
(128 Window
Right
(NW)
6.0 0.390 NFRC 0_37 NFRC 315 90 New _Milgard Classic Low -E Viny,
Zone 2
12 Window
Left
(E)
6.0 .39 NF8Q_Q_31 JCC 90 90 NewL-Milqard Classic Low -E Vinyi
Zone 2
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window
Condition
Overhang
Left Fit Right Fin
#
Exterior Shade Type
SHGC
Hgt
Wd
Len
Hgt LExt
RExt Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
5.0
4.0
2.0
0.1 2.0
2.0
2
Bug Screen
0.76
5.0
5.0
10.0
0.1 10.0
10.0
3
Bug Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
4
Bug Screen
0.76
1.5
1.5
2.0
01 2.0
2.0
5
Buq Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
6
Bug Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
7
Bug Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
8
Bug Screen
0.76
8.0
6.0
6.0
0.1 6.0
6.0
9
Bug Screen
0.76
8.0
6.0
6.0
0.1 6.0
6.0
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
13
Bug Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
14
Bug Screen
0.76
8.0
2.7
2.0
0.1 2.0
2.0
15
Bug Screen
0.76
5.0
3.0
2.0
0.1 2.0
2.0
16
Bug Screen
0.76
5.0
5.0
- 9.5
0.1 2.0
2.0
17
Bug Screen
0.76
8.0
2.7
9.5
0.1 2.0
2.0
18
Bug Screen
0.76
3.0
2.0
2.0
0.1 2.0
2.0
19
'Bug Screen
0.76
3.0
2.0
2.0
0.1 2.0
2.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type Length
R' -Val. Location JA IV Reference
Status
Comments
Slab Perimeter 110
None No Insulation 26-A1
New
Zone 1
Slab Perimeter 234
None No Insulation 26-A1
New
Zone 2
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig042307 Page:4 of 13
Certificate Of Compliance • Residential (Pal 2 of 4) CF -1 R
THE LAYTON RESIDENCE 6/13/2007
Project Title
Date
FENESTRATION SURFACES.
# Type Area U -Factor' SHGC2 True Cond. Azm. Tilt Stat. Glazin
Location/
Comments
`_m'Windnw
Front
(N) An n igo NERC n 37 ERr qn New Milgard Caaccir I
c213wWindow
Front
_n ow- Vinyl
(N) 4.0 0.390 NFRC 0_37 NFRC 0 90 New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
Q27 Window
(23
Front
Front
(N) 40.0 0.390 NFRC 0_37 NFRC 0 90 New Milgard Classic Low -E Vinyl
(N)
Zone 2
-Window
x"243 Window
Left
40.0 0.390 NFRC 0_37 NFRC 0 90 New Milgard Classic Low -E Vinyl
(E)
Zone 2
25 --Window
Left
30.0 0.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl
Zone 2.
�3fz6
21 Bug Screen
Lj 48.0 0.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl
Zone 2
48.0 0_390 NFRC0_____37 NFRC 90 90 New Milgard Clastic I Vinyl
%_;Window
PMIindow
Left
ow -E
(E) 6.00.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
2.0
Left
(j) 6.0 0_390 NFRC0_37 NFRC �� _90 New Milgard la i . I qw_ inyl
Zone 2
2Q Window
Left
() 6.0 0_390 NFRC 0_37 NFRC _ 90 90 blew Milgard Classic LOMI-E Vinyl
2.0
c3QWind0w
r39 -Window
Left
Left
(E) 20.0 0_390 NFRC0 37 NFRC 90 90 New Milgard Classic Low -E Vinyl
(E)
Zone 2
Zone 2
2 --Window
L ft
2.2 0.390 NFRC 0_37 NFRC 9090 New Miloard Classic Low -E Vinyl
Zone 2
2.0
j_ 2 p NFRC 0_37 NFRC' �W New Milgard Clacci I Vinyl
0.76
X33 :Window
C34:7 -Window
Left
Left
_K . QW -E
(E) 2.2 0.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
X35 -Window
Rear
(E) 2.2 0.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl
(S) 6.0
Zone 2
!3�'r`Window
Rear
0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
(S) 6.0 0.390 NFRC 0_37 NFRC' 180 90 New
Zone 2
37 Window
Rear
Milgard Classic Low -E Vinyl
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
1lVindow
Rear _(
24.0 0_390 NFRC0_37 NFRC 180 90 New Milgard Classic Low -E Vinvl
7nn0 9
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B
INTERIOR AND EXTERIOR SHADING
# Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhang
Left Fin Right Fin
Len. Hgt.
20 Bug Screen
0.76
3.0 2.0
LExt.
2.0 0.1 2.0
RExt.
2.0
Dist.
Len. Hgt. Dist. Len. Hgt.
21 Bug Screen
0.76
22 Bug Screen
0.76
5.0 8.02.0
0.1 2.0
2.0
23 Bug Screen
24 Bug Screen
0.76
8.0 5.0
2.0 0. 2.0
2.0
25 Bug Screen
0.76
0.76
5.0 6.0
8.0 6.0
2.0 0.1 2.0
5.0 . 2.0
2.0
2.0
26 Bug Screen
27 Bug Screen
0.76
8.0 6.0
_
5.0 0.1 2.0
2.0
0.76
28 Bug Screen
0.76
29 Bug Screen
0.76
30 Bug Screen
0.76
31 Bug Screen
0.76
32 Bug Screen
0.76
33 Bug Screen
0.76
34 Bug Screen
0.76
35 Bug Screen
0.76
3.0 2.0
2.5 0.1 2.0
2.0
36 Bug Screen
0.76
3.0 2.0
2.5 ' 0.1 2.0
2.0
37 Bug Screen
0.76
1.5 1.5
2.0 0.1 2.0
2.0
38 Bug Screen
0.76
8.0 3.0
16.0 0.1 2.0
2.0
THERMAL MASS FOR HIGH
MASS DESIGN
Area
Type
Thick. Heat
Inside
Condition
Location/
(sf)
(in.) Cap. Cond. R -Val.
JA IV Reference
Status
Comments
Insulation
PERIMETER LOSSES
Condition
Location/
Type Length
R -Val.
Location
JA IV Reference
Status
Comments
4.3 by EnergySoft User Number: 5732 Job Number:
5of13
Certificate Of Compliance : Residential (Par. 3 of 4) CF -1 R
THE LAYTON RESIDENCE
Tank
Energy
Tank Insul.
6/13/2007
Project Title
Condition Factor
Standby R -Value
Date
(gal)
HVAC SYSTEMS
Loss (%) Ext.
Rheem 41VRP50PT Small Gas No Pipe Insulation 2 40,000
50
New 0.65
Heating
Minimum
Cooling
Minimum
Condition Thermostat
Location Type
Eff
Type
Eff
Status Type
HVAC System - Zone 1 Central Furnace
80% AFUE
Split Air Conditioner
13.0 SEER
[Jew Setback
HVAC System - Zone 2 Central Furnace
80% AFUE
Split Air Conditioner
13.0 SEER
slew Setback
HVAC DISTRIBUTION
Duct
Location Heatinq Coolinq Location
HVAC System - Zone 1 Ducted Ducted Attic
HVAC System - Zone 2 Ducted Ducted Attic
Hydropic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Duct Condition Ducts
R -Value Status Tested?
6.0 New Yes
6.0 New Yes
WATER HEATING SYSTEMS Rated
Tank
Energy
Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Standby R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE
Loss (%) Ext.
Rheem 41VRP50PT Small Gas No Pipe Insulation 2 40,000
50
New 0.65
n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
REMARKS
This calculation supercedes all previous reports. SLO - June 13-07
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that.Dopaptiance using duct design, duct sealing, verification of refrigerant charge and TXVs„ insulation installation quality,
and building envelope se it ller testing and certification and field verification by an approved HERS rater.
Designer or Ow a ess ofessions Code) Documentation Author
Name: C� %1/i /GJi& Name: S.L.O.
Title/Firm: LLEZ DESIGN AND ASSOCIATES Title/Firm: Santiago Lopez-Ocampo
Address:
Telephon : 7,AO.98 Lic. #:
(s' n ure) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature) (date)
Address: P.O. Box 1018
La Quinta, CA 92247
Telephone: 760 485-8927
s•�s•a7
(signature) (date)
EnerayPro 4.3 by EneravSoft User Number: 5732 Job Number: lg042307 ' _ Page:7 of 13 1
Certificate Of Compliance : Residential (Par 2 of 4) CF -1 R
THE LAYTON RESIDENCE
Project Title Date
6/13/2007
FENESTRATION SURFACES
True Cond.
# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type
Location/
Comments
'446Window
Rear
(S) 99 0 390 MERG JLU NFRC 180 _,qD- New Milgard Classic Low -F Vinyl
Zone 2
0401 Window
Rear
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
c4_11 Window
Rear
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
c42=Window
Rear
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
�43�. Window
A indow
Rear
Rear
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
($) 15.0 0.390 NFRC 0_37 NFRC 180. 90 New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
45 -Window
Rear
(S) 15.0 0.390 NFRC 0_37 _NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
C-46,p.Window
Rear
(S) 15.0 0.390 NFRC 0.37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
�1NindoW
t1$ Window
,44Z /endow
Rear
Rear
Rear
(,S.) 15.0 0.390 NFRC 0.37 NFRC 180 90 New Milgard Classic Low -E Vinyl
(,S 2.2 0.390 NFRQ'0.37 NFRC 180 _ 90 New Miloard Classic Low -E Vinyl
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
Zone 2
50,p -Window
6 indow
Rear
Rear
(S) 2.2 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl
(S) 2.2 0.390 NFRC 0.37 NFRC 180 qO New Milgard Classic Low -E Vinyl
Zone 2
Zone 2
,(5-2) Window
Rear
(S) 160.0 0.390 NFRC 0.37 NFRC 180 90 New Milgard Classic Low -E Vinyl
Zone 2
453=Window
Right
(W) 15.0 0.390 NFRC 0_37 NFRC 270 90 New Milgard Classic Low -E Vinyl
Zone 2
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fir Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt. LEA.
RExt. Dist. Len. Hgt. Dist. Len. Hgt.
39
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
40
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
41
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
42
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
43
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
44
Bug
Screen
0.76
5.0
3.0
16.0
_0. 2.0
2.0
45
Bug
Screen
0.76
5.0
3.0
16.0
0.1 2.0
2.0
46
Bug
Screen
0.76
5.0
3.0
16.0
0.1 2.0
2.0
47
Bug
Screen
0.76
5.0
3.0
16.0
0.1 2.0
2.0
48
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
49
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
50
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
51
Bug
Screen
0.76
1.5
1.5
2.0
0.1 2.0
2.0
52
Bug
Screen
0.76
10.0
16.0
13.5
0.1 2.0
2.0
53
Bug
Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation
Tvoe Lenath R -Val. Location JA IV Reference
Condition Location/
Status Comments
Run Initiation Time: 06/13/07 00:01:55 Run Code: 1181718115
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: lg042307 Page:6 of 13
Certificate Of Compliance : Residential (Par 4 of 4) CF -1 R
THE LAYTON RESIDENCE 6/13/2007
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items eequire special
written justification and documentation, and special verification to be used with the performance approach. The -local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
3asea on the aaequacy of the special Jusntication ana aocumentation submitted. I- Plan Field
The Roof "R-38 Roof Attic w/Radiant Barrier" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
HERS Required Verification `
Items in this section require field testing and/or verification by a certified home energy rater under the supervisi=on of a
HERS provider using approved testing and/or verification methods.
Plan
Field
The HVAC System "HVAC System - Zone 1" incorporates HERS verified Duct Leakage. Target leakage is calculated a id documented
on the CF -4R.
The HVAC System "HVAC System - Zone 1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
The HVAC System "HVAC System - Zone 2" incorporates HERS verified Duct Leakage. Target leakage is calculated a: -Id documented
on the CF -4R. ,
,
The HVAC System "HVAC System - Zone 2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion'Valve.
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: lg042307 Paae:8 of 13 1
ti-
e ,
Mandatory Measures, Summary: Residential-, • .(Page.I of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on.this checklist only.
DESCRIPTION Check or initial applicable bones or check NA if not applicable and included with the
El
❑'
ENFORCE -
permit application documentation.'
NIA
DESIGNER
MENT .
Building Envelope Measures
+§ 150(a): Minimum R-19 in,wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b)` Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
r ,
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
N'
❑
apply to exterior mass walls). '
t
❑X
❑'
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
El
❑'
"'I-] . ❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have: !.
a. closable metal or glass door covering the entire opening of the firebox y
❑
❑X
• ❑
b. outside air intake with damper and control, flue damper and control
❑
❑X
v, .❑
2. No continuous burning gas pilot lights allowed.
❑
❑X
❑'
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual
❑
❑X
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. { !
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
j
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑X
❑
CF -6R Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.;
❑
❑X
❑ .
2.' Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
❑X
❑
Coefficient (SHGC), and infiltration certification.
,'3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ -
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
r
§' 110-13: HVAC equipment, "water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑ 7
❑X
;+ ❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. r:
❑
❑X
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
• ❑
having an installed thermal resistance of,R-12 or greater.
,.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external _
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value:
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
-❑
El
indirect hot water tank shall be insulated to Table 150-B and: Equation 150-A:
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑ .
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
11
El;
El,
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is, enclosed
r ❑
❑
t ❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ,
❑
❑
` ❑
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig042307
Page:9 of 13
Mandatory Measures Summary: Residential (Page 2 of 2) WAR,
NOTE: Lowrise residential, buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 504, ❑
605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of
R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed.in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operatic g
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
0 ❑
0 ❑
7. Flexible ducts cannot have porous inner cores.
❑ 0 ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ " ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ 0 ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ 0 ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑X ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ 0 ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ x❑ ❑
controlled by an occupant sensor that complies with Section 1'19(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑X ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑X ❑
same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(c).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
_
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.3 by EnergySoft User Number:..5732 Job Number: Ig042307
Page: 10 of 13
f
Residential Kitchen Lighting` Worksheet - WS -5R
THE LAYTON RESIDENCE 6/13/2007 '
Project Title Date
At least 50% of the total rated wattage of permanently Installed luminaires In kitchens must be In luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. "
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type ' a High Efficacy? Wafts Quantity Watts Other Wafts
(1) 2 ft U -Tube T8 Elec Yes X No 39.0 x 6 = 234
or
(1) 26w Compact Fluorescent Triple 4 Pin Yes X No 28.0 .x 9 - 252 or
ec Yes No _`
x - or
Yes . No x = f or
Yes No x or
Yes No x - or s
( Yes No x = or
'Yes No x _ or
` Yes No x - or
Yes No x - or
Yes No x = or
Yes No x = or
' Yes No x = or,
Yes No x = or y 1
Yes No x = or
Yes No x _ or
Yes No x = or
¢ Yes No x = or
Yes No x or
Yes No x = or
Total - A: 486 B- 0
y COMPLIES IF A;-,- B YES ® NO ❑
r
J
EnergyPro 4.3"by EnergySoft - User Number: 5732 Job Number: ]g042307 Page: 11 of 13
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
THE LAYTON RESIDENCE 6/13/2007
SYSTEM NAMEFLOOR AREA
HVAC System - Zone 1 1,428
Fmr�wFizpmr, CMFCKS
Number of Systems
1
Heating System
Output per System
80,000
Total Output (Btuh)
80,000
Output (Btuh/sqft)
56.0
Cooling System
Output per System
48,500
Total Output (Btuh)
48,500
Total Output (Tons)
4.0
Total Output (Btuh/sqft)
34.0
Total Output (sgfttTon)
353.3
Air System
CFM per System
1,600
Airflow (cfm)
1,600
Airflow (cfm/sgft)
1.12
Airflow (cfm/Ton)
395.9
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS
26.0°F 69.1°F 69.1°F
Outside Air
0 cfm
Supply Fan
1600 cfm
69.1 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
LF -tent
CFM
Sensible
1,00
22,345
1,92
381
18,375
0
2,029
1,464
0
0
0
0
0
0
0
0
J
0
2,0291
1,464
1 26,402 1,92 21302
YorkCZB48.PS8CN100.1600cfm 39,789 2,464 80,000
Total Adjusted System Output
78 2,464 80,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
rstream Tel
I 116.1oF
Heating Coil
f% Return Air Ducts 11
Supply Air Ducts
115.30F
ROOMS
70.0 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.6OF 79.2/63.4°F 79.2/63.5°F 55.8/54.5OF
Supply Air Ducts
Outside Air O
0 cfm Supply Fan Cooling Coil 57.0 / 55.0 of
1600 cfm 43.7% R.H. ROOMS
79.2/63.4 of 78.0 / 63.0 OF
I
Return Air Ducts `S
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: Ig042307 Page: 12 of 13
rHVA6 SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
THE LAYTON RESIDENCE 6/13/2007
SYSTEM NAME FLOOR AREA
HVAC System - Zone 2 2,469
ENGINEERING CHECKS SYSTEM LOAD
1 11
Number of Systems
1
Heating System
Output per System
80,000
Total Output (Btuh)
80,000
Output (Btuh/sgft)
32.4
Cooling System
Output per System
57,000
Total Output (Btuh)
57,000
Total Output (Tons)
4.8
Total Output (Btuhlsgft)
23.1
Total Output (sgft/Ton)
519.8
Air System
CFM per System
1,800
Airflow (cfm)
1,800
Airflow (cfm/sgft)
0.73
Airflow (cfm/Ton)
378.9
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
JEATING SYSTEM PSYCHROMETRICS
26.0 of 68.4 of 68.4 of
Outside Air 0
0 cfm
68.4 of
111.0 / 77.6 of
0
Outside
0 cfm
79.5/64.1 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
L�.tent
CFM
I Sensible
1,534
32,263
2,883
915
37,624
0
2,929
2,997
0
0
0
0
0
0
0
0
0
2,929
21997
38 12 2=883
43 617
YorkCZB60.PS8CN100.2000cfm
43,726
6,503
Total Adjusted System Output43,726
(Adjusted for Peak Design Conditions)
6,503
80,000
80,000
TIME OF SYSTEM PEAK Avg 2 pm Jan 12 am
Supply Fan Heating Coil
1800 cfm
1% Return Air Ducts 4
79.5 / 64.1 of 79.5 / 64.2 of 56.7 / 55.4 of
Supply Fan Cooling Coil
1800 cfm
Supply Air Ducts
108.6 of
ROOMS
70.0 of
Supply Air Ducts
58.2 / 56.0 of
45.7% R.H. ROOMS
78.0 / 63.6 of
Return Air Ducts it
EnergyPro 4.3 by EnergySoft User Number: 5732 Job Number: lg042307 Page: 13 of 13