Loading...
0304-181 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and. Professionals Code, and my License is in full force and effect, License # Lic, Class Exp. Date 760044; //Y :VS Date ignature of Co't 'actor Contractor r OWNER -BUILDER DECLARATION I hereby affirm under. penalty of perjury that I -am exempt from the Contractor's License Law for the following reason: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to Construct the project (Sec. 7044, Businesi &,.Priofessionals Code). ? I ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner /WORKER'S COMPENSATION DECLARATION I her6ly affirm juiider' penalty of perjury one of the followi6g declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, ras provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (V) I have and will maintain workers' compensation insurance, as required by Se*rtion 3700 of the *Labor Code, for the performance of the work for which this permit is'issued. My workers' compensation insurance carrier & policy no. are: Carrier STATI B F1JN D Policy No. 46-ftO3••$353 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify.that in the performance of the'work for which this permit is issued, l,shall not employ any person in any manner so as to become subject to the - workers' compensation laws of California, and agr6e that if I should become subject to the workers' compensd 'ti6 provisions 6f !Section 3700 of the Labor Code, I Dafte: shallfor - t6ith comply with those provisions. 'li� t kk:i A -V QAp�p, Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless 'the City. of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above.information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize, representatives of this City to enter upon the above-mentioned p1ropeAy for inspection purposes. ignature (Ener/Agen!)t+. I I � 12 BUILDING PERMIT PERMIT#0304-1111 DATE VALUATION LOT TRACT `236,597,40 b 96 JOB SITE APN ADDRESS T, . 764-044D-010 I OWNER CONTRACTOR / DESIGNER / ENGINEER . .1 _FfkZ1STPfijCV1CA 1.,T;VF:WPW7.NTC-0RP. 5 h M -r CHRtV AVENU111TM 105 5 E, CITRUS AVE 14111"VER 205 R E, DL.A.1 NYD S, 11 CA 923731 RMLANDS CA 92373 (909)198 3688 CBLA 4911 USE OF PERMIT SYD sLOT P5 PIAN 711;PERMIT DOES NOT DNCLUDY, EWCKWAL Pool, SPA 0&, _DRfVnVA Y APPROACH. 13% RLDUCTION TO PL4N CHECK 173B- DUZ TO mmmpiz, iissuawm. or s--&mF, Pt -P-1.4 TwE CUSTON CONENJIUCTION 2,780.00 or POR 550.00 SF 0ARAMMARPORT M9.00 81: EST MIMI D Cog or COVIS11RU(IMON RE-WAHTFri 7i! MUMATZY COSY N RUCTION FEE iol-000-418-000 11,JJ9,00 PLIA14 %Ckl= FM 1ALC1IMICAL ME $163,00 RL"ECTk.RICA-F U?,' 4 10 't -0004420-000 PLUMMBF0, In FLM '101-000-419-.000 $173.25 STRONG MOT1014 PRE - RESID 101-000-241-000 $23.66 ORAD.1140 FEE 101-000.423-000 $15.00 DEVEDOPER IMPAC; PZF, ART M FUSUC PIACIM - r(El 11127 10-000-iP!5­000 191.49 Vii; -TTY L COW: JM10 X ALTO 1:>LAkf CIC- CX U103 PR&PAID FTW, DEC 5 2003T FERWM]IMIS DUIR KGW CITY OF F A QUINTA FINANCE DEPT. RECEIPT DATE BY DATE FINA /JD INSPECT 91R i_2 1 7 10�2 C-1-1 I *N , 236,597,40 $4,416.2-1 . $01,00 $4,41627 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings 1J Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing v ti Compressor Insulation / v Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath ?� Drywall - Int. Lath Final Final POOLS - SPAS BLOCKJAPPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I I Gas Piping PLUMBING APPROVAL Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Lour Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) s rZLA QUINTA e o EC �IJIL ETY DEPARTMENT J 77 -7012 CITY OF LA O REQUEST LINE -7153 CE DEPT. . INAN Owner IE HOMES 111, LLC Contractor FIRST PACIFICA DEVELOP.CORP. Permit Number 0304-181 POST ON JOB IN CONSPICUOUS PLACE - INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 56-192 VILLAGE DRIVE •. SFD - LOT 96 PLAN 2B. PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH _ TYPE OF INSPECTION DATE INSP. TEMPORARY POWER SETBACKS i U/G PLUMBING / WASTE U/G ELECTRICAL / GROUNDING FOOTINGS / STEEL ;� n CONCRETE SLAB 1' DO NOT POUR CONCRETE UNTI, Oy SIG -ROOF NAIL / PRE -ROOF OKAY TO WRAP FRAMING COMBINATION ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL I INSULATION Zfl? j COVER NO WORK UNTIL AID30VE S GNED INTERIOR GYP. BD. DRYWALL7z'41 /15 el EXTERIOR LATH 0 '64 GAS TEST Z z SEPTIC ABANDONMENT - SEWER CONNECTION & SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS t . PRE-GUNITE / SETBACKS U/G PLUMBING U/G CAS j U/G ELECTRICAL PRE -PLASTER ALARMS / BARRIERS FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER m j o se ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ._ 6• ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING Certificate of Occupancy Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 56-192 VILLAGE DRIVE Use classification: SINGLE FAMILY DWELLING Occupancy Group: R3 Owner of Building: BIRDIE HOMES 111, LLC Building Official Type of Construction: VN Building Permit No.: 0304-181 Land Use Zone: RL Address: 5 E. CITRUS AVE. STE. 105 City, ST, ZIP: REDLANDS, CA 92373 By: GARY HARTMAN Date: JANUARY 7, 2005 OUS PLACE V IrCITY OF LA QUINTASUB-CONTRA�jTOR LISTCovd JOB ADDRESS��.1�� `IAIIC PERMIT NUMBtR �OWN+ER /"S 1/ S�S�� BUILDER6-01ee Mool;I-S. This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit For each applicable trade all information requested below must be completed by applicant. "On File" is not an acceptable response. Trade (Classification , Contractor ::: :>::::>::;::<:::<:>::::;:> State:::Contracto .s License... : Worker.Com erlsat�on;Insuranee::' ' • >'::...::`:::.:: Busrie s License:::. City s Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C-12). CONCRETE (C-8) :: f'2ANL0 1&AIS I • G - %%1 � 3-%5 %'3 '{ rtlG� �LrJ$ulav'u �blt O�l(oa- FRAMING .(C-5) : DDl �. Tv�1 .1��. %Sa10 741'010 5 7WtG Co fwMY ?390-0b05(,0'4 a • STRUCT::STEEL (6-51) MASONRY (C•29) PLU.MBiNG (C -36i" NAAJ401 6701!14011 Nvk 3- `3 S159qc1 .00-,31-01 Sfiwlt *iAhaq 1040878-d00*3 3-'~09 /313- 1-3')--01 lLTH: PLASTER IC=35) ��G /l�/(/�'I C� 3� g 7Z 3 �� y3U��j Vit i,40- Baty: WV500013V77 01 /1-1.09 1020a7 6.3`43 DRYWALL(C-9)..:..: a- At /lir 3Y as (.��� �c�lib�J 11-3o-oo 1,ta6.B3to7t2oa— 1 -2q -v5 35-13 g -3t -off HVAC. i%4� C 0-7`-i 0j 3 `>�a- S-31-08 Sim F� 1cu ned dotaBS� -abo- -ol opt 5951 3t ELECTRICAL. (C�101 Vef✓ !� t 71 �'ja}o8 S Cb �fi GvsDal cat Bao t 1-1 a`i' al /03f'og ROOFINGIC=391 ::.?';':> . %�e1 I�OTI�Q% G"J -n l7 ��'30'0''t i go kV, WC,3q���0� 1-01-01 $qi$ I-/ .31 og SHEET METAL (C-431 FLO04RING /! [y 7!D G C�� v-1- G C's 1 7S3$O q 1 Co�1 _ 4038 000so�g'o� O� S310 GLAZING (0-17)%:- INSULATION `(C-2) . SEWAGE DISP -(6-42) -`.' PAINTING (.C-'33).'-: CERAMIC TILE (C-54) CABINETS IC -61 FENCING (C-13) LANDSCAPING (C=27) POOL (C-53) TITLE 24 REPORT Title 24 Report for: MR. & MRS. BUSSMAN - Guest House 56-192 VILLAGE DRIVE La Quinta, Ca 92253 Project Designer: TELLEZ DESIGN P.O. BOX 815 Thermal, CA 92274 760.989.3457 Report Prepared By: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Number: •I I:1: Date: 1/8/2008 Cin OF� LA QUINTA BUILDING & SAFMY DEPT. APPROVED FOR calvernl DA ,111 MAR 2 7 2008 o c� ffC r JAN ; 7 7008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: Ig010808 User Number: 5732 I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 7 9 EnergyPro 4.4 by EnergySoft Job Number: Ig010808 User Number: 5732 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R MR _& MRS __B_USSMAN-Guest Hol fse 1/8/9QQ8 Project Title Date _56-_92_Vll LA.G-DRLV_F l a -Quints Project Address Building Permit # Satlti3 or,A7- carnno (760) 485-8927 Documen tion Author Telephone plan Check/Date -EnerPro CA-C-imat 7ane15 1 Field Check/Date Complig6ce Method Climate Zone TDV Standard Proposed Compliance _ kBtu/sf- r Design Design Margin Space Heating 2.12 1.91 0.21 Space Cooling 79.26 74.88 4.38 Fans 11.33 10.56 0.76 Domestic Hot Water 20.77 22.27 -1.50 Pumps 0.00 0.00 0.00 Totals 113.47 109.63 3.85 Percent better than Standard: 3.4% Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (N) 0 deg Natural Gas Area: 156 ft2 Avg. U: 0.39 Ratio: 18.8% Avg. SHGC: 0.37 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type RVAC-System - Gue t H use 829 -8 290 1 nn Conditioned- -Set-ack- OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt .RooL-.Wood- -829_ -O-M- -R_38_ R -n n 0 1 -Wall_ Wood_ 38D- _0.074 -R_1.9_ _R_0..0_ 0_ 9.0 _Doo- None_ 24 -0_5.01)_ .Mose_ X0_0_ -0__91) Arae- Wood- 2Qa n074 R-19 R-00 9.0 AQ Wall Wood_ 436 0 074 -R_19_ R-0 0_ 180 9,Q -Nall_ Wood_ _200_ -0_074 R_19_ R -n.0_ _27.0_-91) 829 ft2 n/a ft2 0 ft2 829 ft2 10.0 ft 1.00 1 Vent Hgt. Area 2 -n/a Gains Condition Y / N Status JA IV Reference Location / Comments New ni A18 GuesLElouse NLew _O --AS Guest louse New 28-A4 GuesthOusB Mew .09 -AS Guest House New 09 -AS GuesiHouse New 09 -AS Guest -Rouse EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010808 Pane:3 of 9 1 Certificate Of Compliance: Residential (Pa -t 2 of 4) CF -1 R MR. & MRS. BUSSMAN - Guest House 1/8/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazino TVDe Comments -I- 2 ,endow Front Window Front (N) -20..0_ --0-39D NFR.CJ_3Z NFRC 0_ (N) 12.0 0.390 NFRC 0_37 NFRC 0 _90-N.ew Milgard Classic II - V* yl G.uesLljouse 90 New Milgard Classic Low -E Vinyl Guest House 3 Window Front (N) 12.0 0.390 NFRC 0_37 NFRC 0 90 New Milgard Classic Low -E Vinyl Guest House 4 Window Front (N) 20.0 0.390 NFRC 0_37 NFRC 0 90 New milgard Classic Low -E Vinyl Guest House 5 Window Left (E) 15.0 0.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl Guest House 6 Window Left (E) 15.0 0.390 NFRC 0_37 NFRC 90 90 New Milgard Classic Low -E Vinyl Guest House Z Window Rear (S) 4,O 2 390 NFRC -O aZ NFRC 180 90 New Milgard Classic Low -E Vinyl Guest-bosae 8 Window Rear (S) 4.0 0.390 NFRC 0.37 NFRC 180 90 New Milgard Classic Low -E Vinyl Guest House 9- Window Rear (S) 8.0 0.39 NFRC -O3Z SI_ERC _180 _90 NewrdClassic Low -E Vinyl st House 1Q Window Rear 8.0 0.390 NFRC 0.37 NFRC 180 90 New Milgard Classiclow-E Vinyl Guest119use 11 Window Rear (S) 4.0 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl Guest House 12 Window Rear (S) 4.0 0.390 NFRC 0_37 NFRC 180 90 New Milgard Classic Low -E Vinyl Guest House 13 14 Wia�ight-(M 15.0 -0.39 _NERC -O-aZ NFRC -270_ -9D- N.emL-Milgaid-Classic-Low-E_VinyJ Window Right (M 15.0 0.390 NFRC 0_37 NFRC 270 90 New Milgard Classic Low -E Vinyl Gxest- louse Guest House 1. Indicate source either from NFRC or Table 116A. INTERIOR AND EXTERIOR SHADING 1 2 3 4 5 6 7 T- T 10 11 12 13 14 2. Indicate source either from NFRC or Table 116B. Window Overhang Left Fin Right Fin Hat. Wd. Len. Hat. LExt. REA Dist. Len. Hat. Dist. Len. Hat. Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 Bug Screen 0.76 6.0 2.0 2.0 0.1 2.0 Bug Screen 0.76 6.0 2.0 2.0 0.1 2.0 Bug Screen 0.76 4.0 5.0 2. 0.1 2. Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 Bug Screen 0.76 5.0 3.0 2. Q, 24 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 THERMAL MASS FOR HIGH MASS DESIGN 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Location/ Condition Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 01/08/08 03:56:27 Run Code: 1199793387 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010808 Page:4 of 9 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R MR. & MRS. BUSSMAN - Guest House 1/8/2008 Project Title Date HVAC SYSTEMS Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. T-KJR. Instant Gas No Pipe Insulation 2 140,000 0 New 0.81 500 n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: _M ISLi 70e A A -197 Name: SLO Title/Firm: TELLEZ DESIGN Title/Firm: Santiago Lopez-Ocampo Address: P.O. BOX 815 Address: P.O. Box 1018 Thermal, CA 92274 Telephone: 7 Lic. #: (signature (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) La Quinta, CA 92247 T hone: 7 0 485-8927 C> l Cig-OCj (signature) (date) Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System - Guest House Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? ' HVAC System - Guest House Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. T-KJR. Instant Gas No Pipe Insulation 2 140,000 0 New 0.81 500 n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: _M ISLi 70e A A -197 Name: SLO Title/Firm: TELLEZ DESIGN Title/Firm: Santiago Lopez-Ocampo Address: P.O. BOX 815 Address: P.O. Box 1018 Thermal, CA 92274 Telephone: 7 Lic. #: (signature (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) La Quinta, CA 92247 T hone: 7 0 485-8927 C> l Cig-OCj (signature) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R MR. & MRS. BUSSMAN - Guest House 1/8/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These iterrs require special written justification and documentation, and special verification to be used with the performance approach. T. -he local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on ine aaequacy or ine special Justirication ano aocumentation suomittea. I Plan I Field The Roof "R-38 Roof Attic w/Radiant Barrier" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manu4l. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC System - Guest House" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: I010808 Page:6 of 9 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklis- is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ EK ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ Q ❑ § 118: Insulation specked or installed meets insulation installation quality standards. Indicate type and include ❑ O ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExFltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ 11Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ 0 ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 0 ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. ❑ ❑X ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ 0 ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010808 Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach .rsed. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklis,. is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 60-, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment a ❑ © ❑ fR El LLU ❑ ❑ ® ❑ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specked criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ © ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH HEFFIC OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ u factory installed HID( § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 111(d). EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010808 Page:8 of 9 FVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE MR. & MRS. BUSSMAN - Guest House 1/8/2008 SYSTEM NAME FLOOR AREA HVAC System - Guest House 829 26.0 OF 69.0 OF 69.0 OF Outside Air 0 cfm 69.0 of 40 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 639 11,760 1,171 275 10,419 0 1,068 830 0 0 0 0 0 0 0 0 0 1,068 830 13,8951 1,1711 1 12 079 YorkCZB24.PS8Al2N40.800cfm 16,860 4,070 Total Adjusted System Output 16,860 4,070 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I ALg 2 pm 106.6 of Supply Fan Heating Coil 800 cfm res at Time of Ili% Return Air Ducts 4 32,000 32,000 Jan 12 am Supply Air Ducts 105.6 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 79.3/65.6OF 79.3/65.6OF 59.5/58.3OF • Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 60.7 / 58.8 of 800 cfm 507% R.H. ROOMS 79.3/65.6 OF 78.0 / 65.2 of wa.r- A;, n....4� EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010808 Page:9 of 9