Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-0352 (SOL)
P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO • FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT ; INSPECTIONS (760) 77777153 BUILDING PERMIT Date: 3/26/13 Application Number: 13-00000352,. ' Owner: ,•. Property Address: 48310 VISTA CALICO• JACOBS RAYMOND L APN: 649-530-034 - - 48310 VISTA CALICO Application description: SOLAR LA QUINTA,' CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 33312 Fr Contractor. Applicant: Architect or Enginoor. AENOVA ENERGY CORP 75181 MEDITERRANEAN AVENUE ��� 1 �n93 PALM DESERT, CA 9221✓9 '1 t? P 01J (760) 568-3413 �9M Lio. No.: 910836 CITY OF LA QUINTA FINANCE DEPT. ---------------------- UCENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of.consent to self-insure for workers' compensation, as provided - License Class: B C10 C46 LicenseNo.: - 910836 - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is X31 2 K JC ' -1�'„ Q.VA _ issued: DateJ. 2�7 �Contractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor - Code, for the performance of the work for which this permit is issued. My workerscompensation , OWNER-BUILDER DECLARATION - insurance carrier and policy number are: - - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 9024501-12 - following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that; if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by - -3`,01 -3 �' any applicant for a permit subjects the applicant to a civil penalty of.not more than five hundred dollars ($500)-: Date: 1 J Applicant: o/ _ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The _ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL \ Contractors' State License Law does not apply, to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through, his or her own employees, provided that the - DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvementris sold within' SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner-builder will have the burden of proving that he or she did not build or - - • improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT ( 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application.is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request.and for .. pursuant to the Contractors' State License Law.). - whose benefit work is performed under or pursuant to any permit issued as a result of this application, - (_ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being - performed under or following issuance of this permit. - Date: - Owner: - 2. Any permit issued as a result of this application becomes null and void if work is not commenced - within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject - CONSTRUCTION LENDING AGENCY. permit to cancellation. ' he affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all 'work for which this permit is issued (Sec. 3097, Civ. C.). - city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Lender's Name: - - ate:3 L-1 I i Signature (Applicant or Agent): Lender's Address: - - - Application Number . . . . . 13-00000352 Y Permit SOLAR PERMIT 'Additional desc Permit Fee 22:50' `Plan Check Fee 5:63 Valuation Iss Va ation• Issue Date r. a.f 3 3312 Expiration Date '-Qty. Unit Charge Per , ' Extension 'BASE FEE 15.00 1.00 .4.5000 -EA- SOLAR COLLECTOR•<'1000 _ 4.50 t ' 1.00 - 3.0000 EA SOLAR EQUIP MISCELLANEOUS 3.00 ` PermitELEC-MISCELLANEOTTS , • - tiddiLionaLl:desc ? Permit Fee22.50 Plan Check Fee 5.63 Issue Date r Valuation 0 - Y Expiration Date -9/22/13 _ - - Unit Charge c Extension t. .i.Qty. ,Per f . BASE FEE`` " . •3" 15.00 . 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 7.'50 ,- Special Notes and Comments 9.6kW SOLAR ARRAY --(28) 343W SUNPOWER- PANELS W/ (1) 8-,000W SUNPOWER INVERTER " (508SF] 2010 CALIFORNIA ELECTRICAL -CODE. z ' March 26, 2013 7:48:43 AM AORTEGA • ``., -----------------.----------------------------------------- Other'Fees . . . . . . ,BLDG STDS ADMIN (SB1473) - 2.00 Fee summary Charged Paid Credited Due • •---------------------------------------=------- ---------- Permit Fee Total 45.00 00 .00 45.00' Plan Check Total - 11.26 .00 .00 '11.26 Other Fee Total 2.00 .00 .00 2.00 `r .Grand Total 58.26 .00 .00 x•58.26: f LQPERMIT' .. . .. . 1 Bin.# city, 0f U Qil(t1td Building 8L Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit -Application and Tracking Sheet Permit # �; • o35ti ProjectAddress:48310 Vista Calico Owner's Name: Jacobs, Raymond A. P. Number. Address: 48310 Vista Calico Legal Description: City, ST, zip: La Quinta, CA 92253 contractor: Rehova Ener Cor Energy p • Telephone: ProjectDescri tion: Residential Roof Mounted Solar PV 9.6kW DC Address: 75181 Mediterranean Ave city, ST, zip: Palm Desert, CA 92211 -6*J V41, Telephone:760-568-3413 „ 8 State Lic. #: 910836 City Lic. #,104947 , Arch., Engr., Designer Address: City., ST, Zip: Telephone: Y ', State Lic. #: -�_',-,�", Construction Type:. Occupancy: Residential . Project type (circle one): New Add'a Alter Repair Demo Name of Contact Person: Lea Waki - 760-568-3413. Sq. FL: 2924 # Stories 1 -T# nits: Telephone # of Contact Person: lea@ renovasolar. corn Estimated value of Project: $33,31 MID APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan sets Plan Check submitted &JIItem Amount Structural Calcs. Reviewed, ready for corrections Plan Zheck Deposit. Truss Calcs. Called Contact Person Plan `heck Balance Title 24 Calci. Plana picked up Cons. -ruction a Li Flood plainpian Plans resubmitted... Mecharilcal ^ Grading plan 2°4 Review, ready for correct'ionslissue Elect-ical �� �� C� Subcontactor List Called Contact Person Plumbing �- Grant Deed Plans picked up S.M.& H.O.A. Approval Plans resubmitted Grading �- IN HOUSE-- Review, ready for correctionsfissae Deve oyer Impact Fee Planning Approval. Called Contact Person A LP.P. Pub. Wks. App Date or permit issue %vier, School Fees Tota! Permit Fees Mar 21.13 02:43p RANCHO LA QUINTA HOA 7607778961 p,1 -RANCHO ILA QUINTA MASTER A SOCIAT o. Architectural Control Committee March 20, 2013 Mr. and Mrs. Raymond Jacobs 48-310 Vista Calico La Quinta, CA 92253 Re: 48-310 Vista Calico Submission Approved The Architectural Committee reviewed the submission for thermal/passive c•solar installation at your residence; on your roof; submission has been approved. They have studied the submission for esthetic value and find the following: • All work is to be done in accordance with all applicable requirements;of governmental entities, including the City of La Quinta and in accordance with all Homeowners Association architectural guidelines and governing documents. ACity of La Quinta building permit to be obtained and copy furnished to the, Association prior to commencement of work. • Solarpanels shall be intearated into the roof design. Panels and frames MUST be anodized copper or colored to match the roof tiles. Natural aluminum is prohibited. Absolutely no reflective or "shinny" materials can be used: • Panels to have low profile; panels shall be static with no tracking mechanisms and no cables, connections or components may be visible. • No access from Golf Course for this project. When the work has been finished, please return `Notice of Completion" to tie Association Office. The Association's architectural consultant will perform'a final inspection after receipt.of notice;'when verification of the approved plan modifications have been concU.1cled, your Security Deposit will be processed for refund. If you have any questions please do not hesitate to call me at the on-site office 777,8807. , Sincer 111 Cfarp Com' ccAnnm Association General Manager 760-777-8807 fax 760-777-8961" mwalkerPdrminternet.com www.rlgma.com cc: Architectural Comm. P.O. BOX 6419 LA QUIN'TA, CA 92248-6419 - 760-777-8807 • FAX 760-777-8961 • _ _ _ _ _ ' , r _ , • t mss. • ., - f UN -8444 r 100 KVAB Phase: SOLAR.SYSTEM SIZE: 9.604 'kW DC WORK TO BE PERFORMED ACCORDING TO THE - co '• High7.2KV : ' FOLLOWING CODES; 2010 CEC, 2010`CBC' &NEC 2008 - - C `J Low 120/24oV �'' _ GEGAC' SYSTEM SIZE: 8.556 kW AC Q� o r i. CJ CQ� y 20, F ~ s. ' L •'� - :L ;ii-rf� .. «,. 'L, _ r..f i•ri, �• - iv h` rr .4 �^ * BfO • a. dt �l e , r *EXISTING METER # 164S-101'042 - .. ., ,.w • ,.•. `' S^, y � _ - • •t �� '� A - PROPOSED 61-DIRECTIONAIJ�METER• t • y S ::� - - ''� " + • iC y EXISTING 225A MAIN SERVICE ., 3 r v ti a ..:120/240 VOLT ffjj - s ^ s; \• R , LOCATED ON NORTHEAST EXTERIOR WALL" Pv Instaltatton a t:_ ' ' : ..�• L. r r v �y a k. ; - _ Company * Yq t rLIQTE 1. . w t. i' a . *. 0. .. t,, F.+ t1,,/ -P , t ..' ,. - _ t !• •` . ,R•-{ -r - enova Energy Corp' 1 THIS ISA 9.604 KW SOLAR ELECTRIC SYSTEM USING _ t ' a •. Cabtgnia' 2612 s (28) SUNPOWER SPR-343J-WHT-D (343 WATT) PHOTOVOLTAIC MODULES. -• ~' * r MP ' a60 A AC DISCONNECT 2: THIS SYSTEM IS GRID-INTERTIED VIA'UL=LISTED POWER + SQUARE -D #DU222RB C , .�z".. .,� t. r ti. a �� ' s, `,w'4 �,,. hey - r>� CONDITIONING INVERTER: (1) SUNPOWER SPR -8000m-240 •; r , . r it .' is ' * . North American Boardm " 1. " , a r� [ "" 120/240 VOLT ' e` '` �• 3. THIS SYSTEM HAS NO UPS NO BATTERIES. _P - ` \ ' . LOCATED IN GARAGE NABCEPI y n s r 4: THIS IS A ROOF MOUNTED SYSTEM, ADDING 2.68 LB/SQ FT. x l t \\ \ '' Mk. a VENT \ , t FOLLOWING THE ROOF SLOPE. a \'' 't+• . A r , 'ROOF•IS SPANISH TILE AT 15+ PITCH. [ ', INVERTER r r a, \ SUNPOWER 8000.WATT INVE E A-� x ,- t,- +� ., - -` ^ - SPR -8000m-240 r . •• '�', 5: THE SYSTEMS SQUARE FOOTAGE IS 508 FTz. THE MODULES AZIMUTH IS 240°.a '120/240 VOLT " • E a �; i v i 'L'OCATED IN GARAGE 4 t : 3 6. MODULES ARE 0 DEGREES TILT ABOVE ROOF SLOPE. i ", `' • ''' _ t • . f .. 7. BUILDING IS (1) STORIES. „ , `+ *- r + ~t• a 8. LAG SCREWS ARE 3/8" X4" AT 48" O.C.'MAX, WITH 2.5" INTO FRAMING. t ` ` D TO ROOFTOP USING UNIRAC STANDOFF f _ , J co + , 9. MODULES WILL BE SECURE - HIMNEY l ATTACHMENTS. f� #„- "k” x O-.� ' t pSOLAR MODULES"'.- ;" +'r . " .. U U N tz 3 .,' CO N • 10, DESIGNED FOR BASIC.WIND SPEED OF. 100 MPH PER UNIRAC CALCULATIONS. ��` t : '� • r `y `J .11. VISIBLE EXPOSED CONDUIT SHALL BE PAINTED TO MATCH:cup .r .t - '✓• : f " , r '` . �, �. v ^ QUINT tl ! A ,♦ t, ''•f•'• y - ., t ',� �' t•• s i , • N , . ,r Q �• 12: MODULE DIMENSIONS ARE 41.2" X 61.4'' :CITY O F LA Q� � s } � �'Ste* � Q 1, , ; � 0 UILDING & SAFE..IY DEPT. - 13. PROPER CLEARANCES SHALL BE IN ACCORDANCE WITH ALL ADOPTED - "�Y" ` \ /\ t ° °-p a { ;'f ,i +* Z CAL FIRE GUIDELINES: _ 't \ �• ,�' �,� Oo t T,� m; t.r �� O { r..� • sr �.. _ . ,c O''/ . 'f� > .�-�" o C� �H.. _ - .7':.e •ri"Q i' *• h� 7. ,� , ,, : - -.A' tom.. -1 - -��•. t ! is P • t- •k 14. SYSTEM INSTALLATION SHALL: BE PER NEC 690 AND IS SUBJECT TO„ h �' r hY *, F`. „ \ ti; �' '• ` p ` = ` ' E �- � ' µ FIELD INSPECTION BY THE CITY.' r '� Y° FOR' CONSTRUCTIOI�I 3 y \r •<00 * r '- s a ! a r' . i. a . - .� 3 .�' - • l F ► t « •- .. ' .'� r ! - ' } � . `} r ,'i ti ` U LL it . J P ,._ ,:•�'' �r ;' -<.,. �.+ 1;,,, r" ) DATE ��3 BY�.-- ,. o � .•i t - ' .a r..f• - - +' > 1 "' is f, S -;•.i, . - 4iAj' - .5 " j" - •A w - ., IAA\TI ! �- • Drawn By: y - 4 _ .r r ,.ek- ..r y.;.•..� ,•��. , R _:• .S]�' •'Y� •,Y •_ •R'.. ` y \ - - STRING #1sw Y • ; ." t /y •�"' .s - .1. #•, 1v .'r'-• r Sr. ,,, pa t.• ''F { • {:,. _ ♦. 3 . r! _ -!'a e'4 • +!. " e Date Drawn: 2 , -W ESTRING 3/11/13' (p •' f -STRING #3 - , y� Oo�� r �O �� { + Revision No ° ' '400 r C' rk ,STRING r#4 i - _ .. '. �' ► ° - ti, .r r �PQ� v•, . - O Sheet No:cl. xf —r. :. SCALE: 1, 20- • c I �.. WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUC TERMINALS. TERMINALS ON BOTH THE LIN AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. OPERATING CURRENT: 23.96 Amps OPERATING VOLTAGE: 334.31 Volts MAXIMUM VOLTAGE: 520.48 Volts SHORT-CIRCUIT CURRENT: 25.48 Amps NOTE: MOUNT ON DC DISCONNECT OF SPR -8000m INVERTER W FTHIS PANEL IS FED BY TWO SOURCES: I SOLAR PHOTOVOLTAIC SYSTEM ON PREMISES NOTE: MOUNT ON MAIN SERVICE PANEL COVER BACKGROUND "RED" AND "WHITE" LETTERING. WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUC (ERMINALS. TERMINALS ON BOTH THE LIN AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 32 Amps OPERATING AC VOLTAGE: 240 Volts NOTE: MOUNT ON AC DISCONNECT _I 4\ WARNING: THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SITE PLAN 225A MAIN PANEL 60 AMP AC DISCONNECT (INSIDE GARAGE) SUNPOWER 8000W INVERTER (INSIDE GARAGE) NOTE: MOUNT ON SERVICE PANEL SCALE: PROJECT SIGNAGE N/A 3 SUPPORT SYSTEM * WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 100 MPH) * WIND EXPOSURE C * CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY • VISIBLE AND ACCESSIBLE • SOLARMOUNT RACKING SYSTEM, LAG BOLTED DIRECTLY INTO RAFTERS. 3" WARNING INVERTER CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON MAIN SERVICE PANEL AT SOLAR BREAKER W _F PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS AND AT SOLAR BREAKER W PHOTOVOLTAIC DISCONNECT BREAKER LOCATED INSIDE NOTE: MOUNT ON MAIN SERVICE PANEL COVER *ALL PLACARDS SHALL BE RED WITH WHITE LETTERING CITY OF LA QUINTA BUILDING & SAFE T Y. DEPT. A OP P MR C3 V EED FOR CONSTRUCTION SAFEGUARDS * SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED * WILEY CABLE CLIPS * EMT CONDUIT WHERE EXPOSED / ALL METAL CONDUIT -NO SET SCREWS * ALL EMT SHALL USE OUTDOOR COMPRESSION FITTINGS * SERIES CIRCUITS FUSED AT 20 AMPS DC * ALL EQUIPMENT TO BE LABELED * ADD COMBINER / JUNCTION BOX AS NEEDED * BLOCKING DIODE INTERNAL IN EACH MODULE *GROUND FAULT PROTECTION DEVICE BUILT INTERNALLY INTO SUNPOWER INVERTERS *MODULE GROUNDING PERFORMED WITH ILSCO GBL-4DB LUGS WITH #8 SOLID BARE COPPER AND WEEB CONNECTIONS. *ALL NEUTRAL TO GROUND CONNECTIONS ARE TO OCCUR IN MAIN PANEL LOCATION *1" EMT MINIMUM * JUNCTION BOX/ COMBINER BOX ENTRY TO BE COMPRESSION FITTING BY M)kTERIALS ; (28) SUNPOWER 343 WATT PHOTOVOLTAIC MODULES #SPR-343J-WHT-1) (1) SUNPOWER SPR -8000m - 7,680 W; 240 VOLT (1) SQUARE -D AC DISCONNECT, 60A NON-FUSIBLE,2-POLE #DU222RB SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (28 x 343/1000) 9.604 kW CEC-AC SYSTEM SIZE 8.556 kW 2 Jr N W E S NOTES+ SOLAR PRODUCTION STATS. SNAE. 2 I P.V. PLAN ' N/A PANEL: MAIN PANELVOLTAGE: 240/120 3'• N: NON -CONTINUOUS WARNING: BACKGROUND 225 A ELECTRIC SHOCK HAZARD "RED" AND 0 IF A GROUND FAULT IS INDICATED, THE "WHITE" o)UM C NORMALLY GROUNDED CONDUCTORS LETTERING. Cu MAY BE UNGROUNDED AND ENERGIZED. U NOTE: MOUNT ON INVERTER _I 4\ WARNING: THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SITE PLAN 225A MAIN PANEL 60 AMP AC DISCONNECT (INSIDE GARAGE) SUNPOWER 8000W INVERTER (INSIDE GARAGE) NOTE: MOUNT ON SERVICE PANEL SCALE: PROJECT SIGNAGE N/A 3 SUPPORT SYSTEM * WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 100 MPH) * WIND EXPOSURE C * CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY • VISIBLE AND ACCESSIBLE • SOLARMOUNT RACKING SYSTEM, LAG BOLTED DIRECTLY INTO RAFTERS. 3" WARNING INVERTER CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON MAIN SERVICE PANEL AT SOLAR BREAKER W _F PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS AND AT SOLAR BREAKER W PHOTOVOLTAIC DISCONNECT BREAKER LOCATED INSIDE NOTE: MOUNT ON MAIN SERVICE PANEL COVER *ALL PLACARDS SHALL BE RED WITH WHITE LETTERING CITY OF LA QUINTA BUILDING & SAFE T Y. DEPT. A OP P MR C3 V EED FOR CONSTRUCTION SAFEGUARDS * SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED * WILEY CABLE CLIPS * EMT CONDUIT WHERE EXPOSED / ALL METAL CONDUIT -NO SET SCREWS * ALL EMT SHALL USE OUTDOOR COMPRESSION FITTINGS * SERIES CIRCUITS FUSED AT 20 AMPS DC * ALL EQUIPMENT TO BE LABELED * ADD COMBINER / JUNCTION BOX AS NEEDED * BLOCKING DIODE INTERNAL IN EACH MODULE *GROUND FAULT PROTECTION DEVICE BUILT INTERNALLY INTO SUNPOWER INVERTERS *MODULE GROUNDING PERFORMED WITH ILSCO GBL-4DB LUGS WITH #8 SOLID BARE COPPER AND WEEB CONNECTIONS. *ALL NEUTRAL TO GROUND CONNECTIONS ARE TO OCCUR IN MAIN PANEL LOCATION *1" EMT MINIMUM * JUNCTION BOX/ COMBINER BOX ENTRY TO BE COMPRESSION FITTING BY M)kTERIALS ; (28) SUNPOWER 343 WATT PHOTOVOLTAIC MODULES #SPR-343J-WHT-1) (1) SUNPOWER SPR -8000m - 7,680 W; 240 VOLT (1) SQUARE -D AC DISCONNECT, 60A NON-FUSIBLE,2-POLE #DU222RB SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (28 x 343/1000) 9.604 kW CEC-AC SYSTEM SIZE 8.556 kW 2 Jr N W E S NOTES+ SOLAR PRODUCTION STATS. SNAE. 2 I P.V. PLAN ' N/A PANEL: MAIN PANELVOLTAGE: 240/120 1P,3W CIRCUIT CODE: N: NON -CONTINUOUS di cl)Q o 0 BUS: 225 A L: LONG -CONTINUOUS 0 LOCATION: EXTERIOR NORTHEAST WALL o)UM C Q Cco U 'DIn lcc NJ Cu 0) U) �cc � a) p N CD U U���U co E cv R: DEMANDABLE RECEPTACLES MOUNTING: FLUSH Q K: KITCHEN A/C RATING: 10,000 Z VA LOAD o TYPE C.B. BUS C.B. TYPE o VA LOAD U LOAD DESCRIPTION p p LOAD DESCRIPTION it A B L) N R L TR P A B TR P L R N U A B V 1 3840 Sunpower SPR -8000f Inverter L 40 40 2 x L 2 2 3 3840 L - x L 4 3840 3840 PHASE TOTALS PHASE TOTALS L. Date Drawn: PHASE TOTALS A+B CONNECTED VA (CODE N): 3/11/13 TOTAL PHASE A: 3840 CONNECTED VA (CODE L): 7680 TOTAL PHASE B: 3840 CONNECTED VA (CODE R): CONNECTED VA (CODE K): TOTAL CONNECTED KVA: 7.68 DEMAND KVA * EXISTING LOADS UNKNOWN TOTAL ADJUSTED KVA: 7.68 TOTAL PANEL AMPS: 32 4 AMPS W/L,CL: 32 MAIN PANEL SCHEDULE 1 'N,q t' 11 4 NOTES 1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED. 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. (9 ru co di cl)Q o 0 co CL 0 y � co 0 TNQ�N o)UM C Q Cco U 'DIn lcc NJ Cu 0) U) �cc � a) p N CD U U���U co E cv fY ' m •`' Df �a o L U PV Installation Company Renova Energy Corp. .CaGfomia - 2012 10 FTAI • C?Mfed Energy-'rar:+Lener: Revision No 1, Sheet No. E.1 O M LO. m - N p Q rn , U Q � U Q Z Z O > - E >- M 2 o` Drawn By: C. L. Date Drawn: 3/11/13 Revision No 1, Sheet No. E.1 TO IID EXISTING 225 AMP MAIN SERVICE UN -8444 > ARRAYMETER# 1B4S-101042 240/120 VOLT, 2 -POLE 100 KVA B -Phase SOLAR ARRAY O Q SUR PROPOSED BI-DIRECTIONAL LOCATED ON NORTHEAST EXTERIOR WALL High 7.2 kV p ICC N C') It WATT PHOTOVOLTAIC MODULES #SPR-343J-WHT-D ; (2) #8 THWN-2 METER # Low 120/240 V �\ U c [R�a/� (4 STRINGS OF 7 MODULES) (1) #8 THWN-2 NEUTRAL y °o 11) DC DISCONNECT (1) #8 THWN-2 EGC M 0) J I FUSED AT 20 AMPS (1) #8 THWN-2 GEC w (D Na - N C SUNPOWER 1" EMT o 0-8 SPR.MOOI I-240 EXISTING 225A 240 V, 2P ' MAIN BREAKER f C °; E V 6 N - @ aj; n o C 0 U 40 AMP o/V (2) #8 THWN-2 SOLAR (1) #8 THWN-2 NEUTRAL BREAKER ti 60 AMP NON -FUSIBLE (1) #8 THWN-2 EGC N BAR SOLAR BREAKER SUITABLE FOR DISCONNECTING (1) #8 THWN-2 GEC LOCATED IN MEANS PER NEC 690.14 AND 690.17 AC DISCONNECT 1" EMT ' GARAGE SQUARE -D #DU222R6 240V, 2P G BAR 8 THWN-2 LOCATED IN GARAGE () #8 "'ate PV Installation (1) #8 THWN-2 EGC Company P y 1 1/4" EMT LIFER+ Renova Energy Corp. GEC GROUND Calif°mia -.2012 (2) #8 THWN-2 TO 40 AMP 2 -POLE * ALL WIRING BETWEEN MODULES SHALL BE TYPE USE -2 OR PV -WIRE IF EXPOSED. SOLAR BREAKER ALL CONDUIT SHALL BE 1" EMT OR LARGER. CITY OF L _ of � ALL CONDUIT SHALL BE BONDED. NABCEP` ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS. [��ILDING & SAFETY DEPT (1) #8 THWN-2 NEUTRAL STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR JUNCTION BOXES SHALL BE USED ASN E ALL'CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRE& IVD1 #8 THWN-2 GEC A P " �13 #8 THWN-2 EGC FOR CONSTRUCTION *GEC CONNECTED TO MAIN PANEL GND *EMT ENTRY TO MAIN PANEL (2) #8 THWN-2 TO BE DETERMINED IN FIELD DATE gY (1) #8 THWN-2 NEUTRAL (1) #8 THWN-2 GEC (1) #8 THWN-2 EGC 1" EMT SINGLE LINE DIAGRAM SCALE. O LO U N DC CIRCUITS AC CIRCUITS CO rn MODULES TO SUNPOWER 8000W INVERTERQ SUNPOWER'8000W INVERTER TO MAIN PANEL U U 4 STRINGS X 7 MODULES = 28 MODULES 25[PER NEC 215 Record Low°C T coetV)) X # modules in series 7680W / 240 VOLT = 32A X 1..2(A)1] = 40 AMPS (40 AMP SOLAR BREAKER) Q Q MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp [via www.solarabcs.org]) x MAX VOLTAGE DC= (68.1 +((25°C - 3°C) x.1674)) X 7 modules in series = 502.48 VOLTS AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE. Z . U) H Z 6.37 AMPS EACH CIRCUIT X 1.56[PER NEC 690.8] = 9.94 AMPS ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG Q i FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER #8 WIRE = 55 AMPS X .82[PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 45.1 AMPS � CY @ 2 DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. 45.1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(B)(2)(a)] = 45.1 AMPS > 40 AMPS = OK co Z 00 ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG (3) #8 THWC-2 AWG WIRE, (2) #8 TH GROUND � d' _j o #8 WIRE = 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(6)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS 1" EMT @ 40% FILL PER NEC TABLE C.1 = (9) #88 THWN-2 WIRES = OK a 31.9 AMPS X .70[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 22.33 AMPS > 9.94 AMPS = OK Drawn By: 4 STRINGS= (8) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND C. L. 1 1/4" EMT @ 40% FILL PER NEC TABLE C.1 = (16) #8 THWN-2 WIRES = OK Date Drawn: MAIN PANEL BACKFEED CALCULATION EXISTING 225 AMP MAIN SERVICE 3/11/1 120% OF 225 AMP BUSS: ALLOWABLE BACKFED AMPS [PER NEC 690.64(6)(2)] = 270 AMPS Revision No. 270 AMP - 225 AMP MAIN BREAKER = 45 TOTAL AMP ALLOWABLE 40 AMP SOLAR BREAKER < 45 AMPS = OK 0 WORK TO BE- PERFORMED ACCORDING TO THE Sheet No. FOLLOWING CODES: 2010 CEC 2010 CBC & NEC 2008 II E.2 CALCULATIONS SCALE: 2 N/A 21% EFFICIENCY X21 panels, part of the new X -Series modules, use high efficiency third generation Advanced MoxeonT' cells. High efficiency means more power in a given space to maximize return on investment and enable flexibility of future system expansion. BOOSTING POWER OUTPUT SunPower modules take the "LID" off performance. SunPower modules remove "Light Induced Degradation" to improve power by 2-3% compared to common photovoltaic modules, delivering more power and value from your system. BETTER SHADE PERFORMANCE SunPower module technology keeps the module working, even when a shadow sweeps over the module. REDUCED INSTALLATION COST More power per panel means fewer panels to install, fewer rooftop/racking components, and less wiring. This saves both time'and money. RELIABLE AND ROBUST SunPower's unique Maxeon cell technology and module design ensure industry-leading reliability. MAXEONTM CELL.:" TECHNOLOGY =` Patented all back contact solar cell provides industry highest efficiency (up to 24%) and reliability THE WORLD'S STANDARD FOR SOLAR TM X SERIES SunPower solar panels provide today's highest efficiency and performance. The X21, powered by third generation MoxeonT' cell technology, provides panel conversion efficiency of at least 21 %. X series modules deliver extraordinary energy production in full sun and hot, as well as low light and shaded conditions. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE LJ% 20% 15% 10% 5% SERIES SERIES SERIES SERIES sunpowercorp.com C &us i MODEL: SPR-343J-WHT-D Peak Power (+5/-3%) Pmax 343 W Cell Efficiency n 23.6 Panel Efficiency n 21.0% Rated Voltage VmPp 57.3 V Rated Current Impp 5.99 A Open Circuit Voltage Voc 68.1 V Short Circuit Current Isc 6.37 A Maximum System Voltage UL IEC . 600.V 1000 V (Pending) Temperature Coefficients Power (P) — 0.36 %/K (B) Voltage (Voc) -167.4 mV/K Current (Isc) 3.5 mA/K NOCT 45e C +/— 2e C Series Fuse Rating 20A �. �o 0 i Solar Cells 96 SunPower 3rd generation Maxeon cells Front Glass High -transmission tempered glass with , anti -reflective (AR) coating Junction Box IP -65 rated with 3 bypass diodes Output Cables 1000 mm cables / MC4 compatible connectors Frame Anodized aluminum alloy type 6063 (black) Weight 41.0 lbs (18.6 kg) Temperature - 40a F to +1 BY F (- 40a C to + 85" C) Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow) w/specified mounting configurations 50 psf 245 kg/m2 (2400 Pa) front and back (e.g. wind) Impact Resistance Hail: (25 mm) at 51 mph (23 m/s) I Ir.VJG IGVV JVIGIr VIIV IIIJIVIIV IMI IIIJII V\.IIVIIJ VGI VIG VJ111� II IIJ I./IVV V�.Ir YIJ11 JVI1I.JV YY GI �. VI N.V V111 for more details. 0 2012 SunPower corporation. SUNPOWER, the SunPower Logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON are trademorb or registered trodern b s U n p o W e rc o r p . C o m of SunPower Corporation in the US and other countries as well. All Rights Reserved. Specifications included in this datashea are subject to change without notice. Document 11501651 RevA / LTR_EN r C612 190 i 2X 11.0[.43] MM (A) - 2X06.6MOUNTING HOLES (B) -GROUNDING HOLES 30[1 18) �i I (IN) 12X 06.6 [.26] lOX 04.2 (.17] � 2X 577 (22.70] 322[12.69] 180[7.07] 4X 230.8 I I I (B) m j � �o 0 - 1H M 2 8((B _ END ( I r o 1559[61.39] 46[1.81J -� �- .�• 915136.02] (A1 1200(47.24) • e 12[.471 1535[60.451 yr i ... I Ir.VJG IGVV JVIGIr VIIV IIIJIVIIV IMI IIIJII V\.IIVIIJ VGI VIG VJ111� II IIJ I./IVV V�.Ir YIJ11 JVI1I.JV YY GI �. VI N.V V111 for more details. 0 2012 SunPower corporation. SUNPOWER, the SunPower Logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON are trademorb or registered trodern b s U n p o W e rc o r p . C o m of SunPower Corporation in the US and other countries as well. All Rights Reserved. Specifications included in this datashea are subject to change without notice. Document 11501651 RevA / LTR_EN r C612 190 i BENEFITS Reliable and Robust Design Proven track record for durability and longevity Effective Power Range Enables most systems to use a single inverter rather than multiple units Commercial Use Flexible AC voltage output and scalable building blocks create an easy solution for commercial applications High Efficiency Weighted CEC efficiency of at least 95.5% and peak efficiency of at least 96.5% Reduced Installation Cost Integrated DC disconnect with fuses lowers material costs and labor requirements Attractive Aesthetics Integrated disconnect eliminates need for visible conduits to inverter SPR -5000m, -6000m, -7000m and -8000m SunPower SPR -5000m, -6000m, -7000m and -8000m inverters offer superior reliability and performance and can be easily integrated into residential. or commercial installations. All models are backed by a 10 -year warranty. sunpowercorp.com 1-800-SUNPOWER Electrical Data String Inverters SPR -5000m SPR -6000m SPR -7000m SPR -8000m AC Nominal Power 5000 W 6000 W 7000 W 7680 W @ 240 V 141 lbs for SPR -5000m, Inverter Weight -6000m and -7000m / 8000 W @ 277 V AC Max Output 148 lbs for SPR -5000m, Shipping Weight -6000m and -7000m Current (@ 208V, 24 A, 21 A, 18A 29A, 25A, 22A 34A, 29A, 25A N/A, 32A, 29A 240V, 277V): NEMA 3R Mounting Wall Mount AC Nominal 183 - 229 V@ 208 V 183 - 229 V@ 208V 183 - 229 V@ 208V N/A @ 208 V Voltage / Range 211 - 264 V @ 240 V 211 - 264 V @ 240 V 211 - 264 V @ 240 V 211 - 264 V @ 240 V 244 - 305V @ 277 V 244-305V@277V 244-305V@277V 244-305V@277V AC Freq / Range 60 Hz /59.3 Hz - 60 Hz / 59.3 Hz - 60 Hz / 59.3 Hz - 60 Hz /59.3 Hz - 60.5 Hz 60.5 Hz 60.5 Hz 60.5 Hz Power Factor (Nominal) 0.99 0.99 0.99 0.99 Peak Inverter Efficiency 96.8% 97.0% 97.1% 96.5% CEC Weighted 95.5% @ 208 V 95.5% @ 208 V 95.5% @ 208 V N/A @ 208 V Efficiency 95.5% @ 240 V 95.5% @ 240 V 96.0% @ 240 V 96.0% @ 240 V 95.5% @ 277 V 96.0% @ 277 V 96.0% @ 277 V 96.0% @ 277 V Recommended Maximum PV Power 6250 W 7500 W 8750 W 10000W (Module @ STC) DC Input Voltage Range 250 - 600 V 250 - 600 V 250 - 600 V 300 - 600 V Peak Power Tracking Voltage 250 - 480 V 250 - 480 V 250 - 480 V 300 - 480 V DC Max. 21A 25A 30A 30A Input Current DC Voltage Ripple 4% 4% 4% 4% No. of Fused 4 4 4 4 String Inputs PowerConsumpfion: <7W/0.1 W Operation/Nighttime Topology Low frequency transformer Fused DC Disconnect Standard; Complies with NEC Standards Configurable in the field with integrated grounding kit: Electrical Grounding SunPowerT" Solar Panels: DC circuit positively grounded Serengeti- Solar Panels: DC circuit negatively grounded >1 U a A) U SPRm EFFICIENCY CURVES 0% 10% 20% 30% 40% 50% 60% 70% • 80% 90% 100% % of rated output power 24. Mechanical Data t SPR -7000m and SPR -8000m Shipping Dimensions W x H x D (inches) 23.5" x 31.0" x 16.0" Unit Dimensions W x H x D (inches) 18.4" x 24.1" x 9.5" IMMOMMMMMOM 141 lbs for SPR -5000m, Inverter Weight -6000m and -7000m / 148 lbs for SPR -8000m 148 lbs for SPR -5000m, Shipping Weight 0% 10% 20% 30% 40% 50% 60% 70% • 80% 90% 100% % of rated output power 24. Mechanical Data SPR -5000m, SPR -6000m, SPR -7000m and SPR -8000m Shipping Dimensions W x H x D (inches) 23.5" x 31.0" x 16.0" Unit Dimensions W x H x D (inches) 18.4" x 24.1" x 9.5" 141 lbs for SPR -5000m, Inverter Weight -6000m and -7000m / 148 lbs for SPR -8000m 148 lbs for SPR -5000m, Shipping Weight -6000m and -7000m /152 lbsforSPR-8000m Cooling Forced Air/ Sealed Electronics Enclosure Enclosure NEMA 3R Mounting Wall Mount Bracket Standard Ambient Temperature Range -13 to +113 OF Warranty and Certifications Warranty 10 year limited warranty Compliance: IEEE -929, Certifications IEEE -1547, UL 1741, UL 1998, FCC Part 15 A&B 18.4" Founded in 1985, SunPower Corp. (Nasdaq: SPWRA, SPWRB) designs, manufactures and delivers the planet's most powerful solar technology. Residential, business, government and utility customers rely on the company's experience and proven results to maximize return on investment. SUNPOWER and the SUNPOWER logo are trademarks a registered trudernarlu of SunPower corporation. su n powe rCOrp. com OJuly 2010 SunPower Corporation. All rights reserved. Specilii bions included in this datasi-i are su6iwt to charge withom nota- D-ent # 001-16967 RaV*B Unirac - Solarmount / Sunframe Configurator - Project Specs Solarmount / Sunframe Configurator - Project Specs Project Specs Arravinformation Description Name: RayrnortdJacebs Manufacturer: Sanpotner Email: cesar@renouasolar.cem Module Model: E_10527 Telephone: Module Size: 6-.39" x41.18" $72.00 Module Rows xCols 13 203 Proiect Location Number of Arrays 2 City, State: La Quinta, CA Total Modules 5_ Zip code: 92253 Total IGlwalts 1-.004 County Riverside 96 $3.42 Basic Wind Speed: 100 mph (User Modified) Racking Type SalarMount Roofmount Ground Snow Load: 0psf Module Orientation Portrait $2.87 Rail Direction E -W Special Notes on Basic W ind Speed and Snowl-oad STANDOFF W 2 PIECE AL, DRK 96 'ti0- $16.72 $1,604.80 2000 ft. is the upper eleAtion limit in feet for the ground snowload %slue gieen. Single L -Feet SM L -FOOT SERRATED WMDW, DRK 96 96 $4.54 u - Part of the counyis in a Special Wnd Region 0040150 Flashing Material Takeoff Part Number Part Type Description Suggested Quantity ]uantity Unit Price Total 310132C SolarMount Rail SM RAIL 137' CLR 40 40 $72.00 $2,880.00 3030020 Splice SM SPLICE BAR SERRATED DRK 32 32 $6.20 $198.40 302104D Mid Clamps SM MID CLAMP, EFJMN, WHDW, DRK 96 96 $3.42 $328.32 302006D End Clamps SM ENDCLAMP F, WHDW, DRK 16 16 $2.87 $45.92 004600D Aluminum Flat Top STANDOFF W 2 PIECE AL, DRK 96 96 $16.72 $1,604.80 304000D Single L -Feet SM L -FOOT SERRATED WMDW, DRK 96 96 $4.54 $436.21 0040150 Flashing FLASHING OATEY 12920AL, 96 96 $11.59 $1,112.64 308001S UGC Clip SM GROUND CUP #11, UGC -1 SS, 56 56 $2.29 $128.24 Total Price - • Please note these are list prices. Contact your distributor for your system price. $6,734.54 Thermal breaks are required e%ery40 feet. See the Unirac splicing and expansion joint manual for details Engineering Variables Description Variable ValueUnits h _ Building Height _15 R Roof Angle >7to27 degrees Wind Exposure B Pnet30 (Uplift) Importance Factor 1 psf Wind Speed V 100 mph Effective Wind Area 100 112 Roaf Zone 3 1 vmw.unirac.corrdconfig urators/estimator_roofmountt?module=part&task=estimator&mode=detail&type=solar&id=98 1/2 Design Wind Load Calculation Description Variable Value Units Net Design Wind Pressure (Uplift) Pnet30 (Uplift) -38.1 psf Net Design Wind Pressure (Downforce) Pnet30 (Downforce) 7.3 psf Adjustment Factor for Height and EKnosure Category A 1 Importance Factor I 1 Design Wnd Load (Uplift) Pnet (Uplift) -38.1 n psf Design Wind Load (Downforce) Pnet (D—dorce) 7.3 psf Load Combinations Calculations Description Variable Downforce Uplift Units Dead Load D 5 5 psf Total Design Wind Load Pnet _ 10 -38.1 psf Snow Load S 0 Total Load Combination 1 D + 0.75Pnet + 0.755 12.5 psf Total Load Combination 2 D + Pnet 15 psf vmw.unirac.corrdconfig urators/estimator_roofmountt?module=part&task=estimator&mode=detail&type=solar&id=98 1/2 3/11/13 Unirac - Solarmount / Sunframe Config urator - Project Specs 35.1 Total Load Combination 3 D + S 5 psf Total Load Combination 4 0.6D + Pnet -35.1 psf Max Absolute Value Load 35.1 psf Distributed Load (Downforce) Distributed Load Calculation 38.37 Description Variable Value Units MabmwnAbsolute Value of Load Combinations P 35.1 psf Module Length Perpendicular to Rails B 5.12 ft Distributed Load (Uplift) IN -89.78 plf Distributed Load (Downforce) w 38.37 plf Rail Span Information Description Variable Value Units Raddng Attachment Type 4 Single L Solar Mount Point Load Force Racldng Attachment -359.1 AluminiumFlatTop Rail preference SM RAIL 137' CUR Reused Rail Span L 4 ft Allowable Soans Single L Foot SMHD 8 It Double L Foot SM 5 It Double L Foot SMHD 8 ft This engineering report and associated bill of materials is to be e%duated to Unirac SolerMoumt Code Compliant Installation Manual 227.3 (Pub 110616.1cc) and SunFrame Code Compliant Installation Manual 809 (Pub 110518-2cc) which references International Building Code 2003, 2006, 2009 and ASCE 7-05, ASCE 7-02 and California Building Code 2010. The installation of products related to this engineering report is subject to requirements in the above mentioned installation manual. Rev 3.2 - 6252011 I� • p' 2 :t mmw.unirac.com/config urators/estimator_roofhmunY?module= part&taslrestimator&mode=detail&type=solar&jd=98 2/2 Point Load Calculations (per Code, these are based on mazm um allavable spans as shove in chart above) Description Variable Downforce Uplift Units Single SM Point Load Force R 191.8 -448.9 Itis Single SMHD Point Load Force R 307.0 -718.3 Itis Point Load Calculations for your span are: Rail preference SM RAIL 137' CLR Reused Rail Span L 4 ft Solar Mount Point Load Force R 153.5 -359.1 lbs This engineering report and associated bill of materials is to be e%duated to Unirac SolerMoumt Code Compliant Installation Manual 227.3 (Pub 110616.1cc) and SunFrame Code Compliant Installation Manual 809 (Pub 110518-2cc) which references International Building Code 2003, 2006, 2009 and ASCE 7-05, ASCE 7-02 and California Building Code 2010. The installation of products related to this engineering report is subject to requirements in the above mentioned installation manual. Rev 3.2 - 6252011 I� • p' 2 :t mmw.unirac.com/config urators/estimator_roofhmunY?module= part&taslrestimator&mode=detail&type=solar&jd=98 2/2 January 20, 2011 UniRac 1411 Broadway Boulevard NE Albuquerque, New Mexico 87102-1545 TEL: (505) 242-6411 FAX: (505) 242-6412 Attn.: Engineering Department, STRU(TURALENGINEERS Re: Engineering Certification for UniRac's SolarMount Code -Complaint Installation Manual 227.3 PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Code -Complaint Installation Manual 227.3" published October 2010 and specifically "Part I. Procedure to Determine the Design Wind Load", and "Part 11: Procedure to Select Rail Span and Rail Type". The procedures are used to determine the calculation of the design wind force, load combinations, applied loading and rail selection. All information, data and analysis contained within the Installation Manual are based on, and comply with the following: 1. 2009 International Building, by International Code Council, Inc., 2009 2. 2010 California Building Codeby California Building Standards Commission, 2011 3. Aluminum Design Manual: Specifications and Cruidelines for Aluminum Structures, by The Aluminum Association, 2005 This letter certifies that the structural calculations contained within Uni.Rac's "SolarMount Code -Complaint Installation Manual 227.3 are in compliance with the above Codes. If yo}i have any questions on the above, do not hesitate to call. Paul Zacher, 'SE - President 8137 Sunset Avenue, Suite 120 • Fair Oaks, CA 95628 • 916.961.3960 • 916.961.3965 f • WWW.PL .(OH SOLARMOUNTO PV's most versatile mounting system SolarMount is the most versatile PV mounting rail system on the market today. We've engineered installer -friendly components for maximum flexibility, allowing you to solve virtually any PV mounting challenge. The universal SolarMount rail system has three options which can be assembled into a wide variety of PV mounting structures to accommodate any job site. Unirac provides a technical support system complete with installation and code compliance documentation, an on-line estimator and design assistance to help you solve the toughest challenges. 13® IN I rR ■�� Bright Thinking in Solar Visit us online at www.unirac.com SOLARMOUNT® RAIL OPTIONS PV's most versatile mounting system SolarMount• HD HD (heavy duty) rail adds the SolarMount advantage to Pv Pole'rops•, U-LAs (see separate data sheets), and custom applications that require long spans. ATTACHMENT OPTIONS Flexible Components Speed Installation Standoffs Use standoffs whenever Flashed installations • are required, on tile roofs, for example. Two- piecealuminum standoff allow precise place- ment of a Flashing over a secured base prior to the installation of the standoff itself. ^� All standoff types come in four standard heights: 3, q, 6, and 7 inches. Appropriate Flashings are available. Serrated L -feet Standard for ground mount installations on I jT; residential and commercial rooRops,use L -feet alone above asphalt composition shingles or in conjunction with Flat lop standoffs. Mount IILJ' standard or light rails. Configure to either of two rail heights, one promoting air Row for cooling, the other offering close -to -the -roof aesthetics Strut -in -Tube Style legs Quickly set the precise tilt angle required. Styles are available For high profile (1 or z legs per rail) and low profile installations. Each series offers three leg lengths so that you p can adjust to exactly the tilt angle you want— up to a maximum of 6o degrees—without cutting and drilling at the job site. Standard SolarMount° • Standard rail gives you ultimate Flexibility, includingFastFoot'" bottom mounting and tilt -up options. b The FastFoot'" attachment features Eco -Fasten MODULE MOUNTING technology by the Alpine Snow Guard Company, allowing attachments to metal, concrete and wood Asseutbly Seyuelll-e Isi`UUI CIIUiLe of the droofseckwithoutcomPromisingtheintegrity Top Mounting Clamps Bottom Mounting Clips Ideal for Rush mount applica- Use bottom mounting clips �r Tile Hook tions, such as residential rooftops, standard and HD rail only) the hook ( Y) Made from cast aluminum, the ` where it is most convenient to whenever you prefer to attachment provides 5olarMount with a secure footings and rails before preassemble the array using cost-effective solution for barrel or Spanish installing modules, top mounting module mounting holes. 'r: •• • clamps securely grip any point of Simply fit the clip into its rail file roofs. All required lag bolts and hardware the module frame, freeing you slot over the mounting bolt for k are included. Refer to the tile hook engineering from the constraints of module a secure connection. Adjust the data for max load capabilities. mounting holes. clip position anywhere along the rail slot. KEY BENEFITS of SolarMountm Rail Maximum flexibility Flush, high-profile or low -profile configurations Roof or ground mount Pitched or flat roof Ease of installation Installer -friendly components Minimized penetration with longer attachment spans than competitive products Designed with customer input Grounding and wire management options Complete technical support Installation and code compliance documentation Online estimator Person-to-person customer service Core component for Unirac mounting solutions Three rail options to accommodate any job site Incorporated into other major product lines :OAC :°UNIIN Bright Thinking in Solar E Bright Thinking in Solar Component Specifications 6o61 -T6 and 6063-T5 • SolarMount ballast frame 6105-T5 aluminum extrusion • SolarMount® rails Mounting clips and clamps . Tilt legs and L -feet Two-piece standoffs Severe Condition 4 (very severe) zinc -plated welded steel - One-piece standoffs 18 -8 -stainless steel - Fasteners mm UNIRAC no Bright Thinking in Solar Code Compliant The SolarMount® system is PE certified. Call Unirac for documentation applicable to your building code Warranty SolarMount° is covered by a 10 -year limited product warranty and a 5 -year limited finish warranty. For complete warranties, download any SolarMount® installation manual from our web site. Visit us online at www.unirac.com m UNIRAC A HILTI GROUP COMPANY SolarMount Technical Datasheet Pub 110818 -ltd V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip................................................................................................1 MidClamp...................................................................................................................2 EndClamp...................................................................................................................2 SolarMount Beam Connection Hardware.....................................................................3 L-Foot..........................................................................................................................3 SolarMountBeams.........................................................................................................4 SolarMount Module Connection Hardware Be SolarMount Bottom Up Module Clip Part No. 302000C Dimensions specified in inches unless noted • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: —0.031 lbs (14g) • Allowable and design loads are valid when components are assembled with SolarMount sEries beams according to authorized UNIRAC documents • Assemble with one %"-20 ASTM F593 bolt, one %"-20 ASTM F594 serrated flange nut, and one Y-" flat washer • Use anti -seize and tighten to 1)0 ft -lbs of torque • Resistance factors and safety Lgactors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under Serrated flange nut Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, 0 Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, Xt 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, Zt 66 (292) 27 (119) 2.44 41 (181) 0.619 0 ti Ch SolarMount Mid Clamp Part No. 302101 C, 302101 D, 302103C, 302104D, 302105D,302106D LOD DISTANOE 11SWEEN MODULES I 1 I Y 1 � ►X Dimensions specified in inches unless noted SolarMount End Clamp Part No. 302001C, 302002C, 302002D, 302003C, 302003D, 302004C, 302004D, 302005C, 302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C or UNIRAC , A HILTI GROUP COMPANY • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4"-20 T -bolt and one Y4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, X± 1194 (5312) 1 490 (2179) 1 2.44 1 741 (3295)1 0.620 • -, 1 1 MIAIT YARD WITH TNL4G.fSB _, 3 Dimensions specified in ifask�es �a-less ao%d • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: —0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac W-20 T -bolt and one Y4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate lbs (N) Allowable Load' lbs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, 0 Tension, Y+ 1321 (5876) 529 (2352), 2.50 800 (3557) 0.605 Transverse, Z± :63(279) 14 (61) 4.58 21 (92), 0.330 Sliding, X± -142(630) 52 (231) 2.72 79 (349) 0.555 SolarMount Beam Connection Hardware SolarMount L -Foot Part No. 304000C, 304000D Y L, X 'Nf AOT FOR '6 wwnvru� 7.1 —f - Loa _. i , Dimensions specified in inches unless noted s UNIRAC A HILTI GROUP COMPANY • L -Foot material: One of the following extruded aluminum alloys: 6005- T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • L -Foot weight: varies based on height: -0.215 lbs (98g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized 3olt UNIRAC documents L -Foot For the beam to L -Foot connection: • Assemble with one ASTM F593 W-16 hex head screw and one ASTM F594 Wserrated flange nut • Use anti -seize and tighten to 30 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory NOTE: Loads are given for the L -Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, 4) Sliding, Zt 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Traverse, Xt 486 (2162) 213 (949) 2.28 323 (1436) 0.664 m UNIRAC A HILTI GROUP COMPANY SolarMount Beams Part No. 310132C, 310132C -B, 310168C, 310168C -B, 310168D 310208C,310208C-B,310240C,310240C-B,310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area in' 0.676 1.059 Section Modulus (X -Axis) . in' 0.353 0.898 Section Modulus (Y -Axis) in' 0.113 0:221 Moment of Inertia (X -Axis) in° 0.464 1.450 Moment of Inertia (Y -Axis) in° 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 Radius of Gyration (Y -Axis) in 0.254 0.502 SLOT FOR T -BOLT OR 14" HEX HEAD SCREW 2X SLOT FOR BOTTOM CLIP SLOT FOR = 3/s" HEX BOLT 2.500 T 1.316 3 .7 7500 Y l i�X SolarMount Beam SLOT FOR T -BOLT OR 1.728-1 i/4" HEX HEAD SCREW -T SLOT FOR BOTTOM CLIP 3.000 /I L ..-7 SLOT FOR q 1.385 II3/8" HEX BOLT Y F�-1.207 1.875 .A P.�X SolarMount HD Beam Dimensions specified in inches unless noted Standoffs & Flashings Installation Manual 907.2 [1] Installer responsibility AThe installer is solely responsible for: • Complying with all applicable local or national building codes, including any that may supercede this manual; • Ensuring that Unirac and other products are appropriate for the particular installation and the installation environment; • Ensuring that the roof, its rafters, connections, and other structural support members can support the array under building live load conditions; • Using only Unirac parts and installer -supplied parts as specified by Unirac (substitution of parts may void the warranty); • Maintaining the waterproof integrity of the roof; and • Ensuring safe installation of all electrical aspects of the PV array. U N,1 RAC.,A HILTI GROUP COMPANY. • See www.unirac.com/dis&ibutors for your nearest Unirac distributor. Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@urirac.com. :'UNI RAC Installation Manual 907.2 Standoffs & Flashings Standoffs: 3-,4-, 6-, and 7 -inch lengths in each type Shaft O.D. ' Use Components Use only with SolarMount standard or HD rails. • Welded standoff Raised flange 15/8" Secure to rafter with 2 lag screws at opposite • 2 lags, 5/16' x 31/2"* (zinc) zinc -plated steel corners, orienting the flange parallel to the rails. Use with SunFrame, SolarMount standard, or • Welded standoff Flat top I -piece 15/8- SolarMount HD rails. Secure to rafter with 2 lag • Bolt, 3/8- x 11/4 - zinc -plated steel screws at opposite corners. Secure L -foot or • Lock washer, 3/8^ installer -supplied strut directly to standoff with • 2 lags, 5/16' x 31/2"* standoff hardware. 9 s Flat top 2 -piece aluminum Use with SunFrame, SolarMount standard, or SolarMount HD rails. Secure to rafter with 2 lag screws. Secure L -foot or instiller -supplied S/8" strut directly to standoff with standoff hardware. Especially convenient when Installing over a tile roof because flashing can be precisely fitted over secured base prior to installation ofshaft. • Shaft • Base assembly • Bolt, 318' x 11/4- Flange Head • Lock washer, 3/s- • 2 lags, 5/16- x 31/2"* (zinc) • EPDM Washer * A lag-boh removal credit is available wherever an installer prefers to substitute a different lag bolt The installer is solely responsible for determining wheth- er lags are adequate to handle live and dead loads under wind conditions at the installation she. Wind loads and lag pullout capacities are addressed in Code -Compliant installation manual for SolorMount (installation Manual 227) and SunFrame (Installation Manual 809). Flashings for all current standoffs (0/8" O.D. shaft (see illustrations, p. 3) *Pocks of.12 (lashings Flashings for other uses ('/2- - 11/8" O.D. shaft) Part no. Dimensions Collared, galvanized 990109 8.75- x 12.5" Flashing refers to thin, continuous pieces of sheet metal or other impervious material installed to prevent the passage of water into a structure from an angle or joint. Flashing generally operates on the principal that, for water to penetrate a joint, it must work itself upward against the force of gravity or in the case of wind -driven rain, it would have to follow a tortuous path during which the driving force will be dissi- pated. �: • E- ,: is 1,. i + , Unirac offers flashings to be used specifically with Unirac standoffs. These flashings are collared, thereby eliminating the need for the use of sealant between standoff and flashing. The flashing slides over the standoff, under the shingle above, and over the shingle below. The following installation instruction provides an explanation of planning and installation of three different applications. Part no.* Dimensions Collared, galvanized 990101 8.75-x 12.5" Collared, aluminum 990102 8.75" x 12.5" Collared, soft aluminum 990103 18-X 18" *Pocks of.12 (lashings Flashings for other uses ('/2- - 11/8" O.D. shaft) Part no. Dimensions Collared, galvanized 990109 8.75- x 12.5" Flashing refers to thin, continuous pieces of sheet metal or other impervious material installed to prevent the passage of water into a structure from an angle or joint. Flashing generally operates on the principal that, for water to penetrate a joint, it must work itself upward against the force of gravity or in the case of wind -driven rain, it would have to follow a tortuous path during which the driving force will be dissi- pated. �: • E- ,: is 1,. i + , Unirac offers flashings to be used specifically with Unirac standoffs. These flashings are collared, thereby eliminating the need for the use of sealant between standoff and flashing. The flashing slides over the standoff, under the shingle above, and over the shingle below. The following installation instruction provides an explanation of planning and installation of three different applications. Standoffs & Flashings Installation Man �tal 907.2 : UNI RAC Planning and installation There are many possible configurations of standoffs and flashing. The three examples here illustrate major product varieties and installation settings. Example 1 2 -piece, aluminum, flat top standoff Soft aluminum flashing Tile roof SunFrame (shown) or SolarMount rail SunFrame x rail %� L -foot Til Mold flashing Rafter to tile Remove a tile over a rafter. Install the base of a two-piece standoff, ensuring that both lag bolts are screwsd into the rafter. Install soft aluminum flashing over the base, inserting it under the tile above and forming it to the shape of the tile. Insert standoff shaft through the opening in the flashing, screwing it down firmly in place onto the base. Seal with roofing cement or other appropriate compound. Attach L feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Insert footing bolts through L feet and fasten with flange nuts. Example 2 1 -piece, steel, flat top standoff No -Calk- flashing Shingled roof SunFrame (shown) or SolarMount rail SunFrame k Shingle rail L -foot Raffer a No -Calk collar --► Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install the standrff, ensuring that both lag bolts are screwed into the rafter. Insert the flashing under the shingle above and over the shaft of the standoff. No -;alk collar does not require sealing of the flashing and standoff shaft. Attach L—feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Ins °rtfooting bolts through L feet and fasten with flange nuts. U N I RAC Installation Manual 907.2 Standoffs & Flashings Example 3 1 -piece, steel, raised -flange standoff No -Calk' flashing Shingled roof SolarMount rail SolarMount rail Shingle tY" Rafter No -Calk collar -► Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install the standoff, ensuring that (1) both lag bolts are screwed into the rafter, and (2) the raised flange is oriented parallel to the rail. Insert the flashing under the shingle above and over the shaft of the standoff. No -Calk"' collar does not require sealing of the flashing and standoff shaft. Slide mounting bolts along slot on SolarMount rail. Insert footing bolts through raised flange on standoff and fasten with flange nuts. 10 year limited Product Warranty Unirac, Inc., warrants to the original purchaser ("Purchaser") of product(s) that it manufactures ("Product") at the original installation site that the Product shall be free from defects in material and workmanship for a period of ten (10) years, from the earlier of 1) the date the installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original Purchaser.This Warranty does not cover damage to the Product that occurs during its shipment, storage, or Installation. This Warranty shall beVOID if installation of the Product is not performed in accordance with Unirac's written installation instructions, or if the Product has been modified, repaired, or reworked in a manner not previously authorized by Unirac IN WRITING, or if the Product is installed in an environment for which it was not designed. Unirac shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by the Purchaser under any circumstances. If within the specified Warranty period the Product shall be reasonably proven to be defective, then Unirac shall repair or replace the defective Product, or any part thereof, in Unirac's I sole discretion. Such repair or replacement shall completely satisfy and discharge all of Unirac's liability with respect to this limited Warranty. Under no circumstances shall Unirac be liable for special, indirect or consequential damages arising out of or related to use by Purchaser of the Product Manufacturers of related items, such as PV modules and Flashings, may provide written warranties of their own. Unirac's limited Warranty covers only its Product, and not any related items. FUNIRAC 1411 Broadway Boulevard NE Albuquerque NM 87102-1545 USA 4 Wiley Electronics. LLC Washer, Electrical Equipment Bond WEEB Patent Pending INSTALLATION INSTRUCTIONS For Unirac Solar'Mount only Please read carefully before installing. q WEEB-UMC WEEBL-6.7 WEEB Bonding Jumper -6.7 : C ( �S Products.are tested to UL -467 3098177 UL standard for safety grounding and bonding equipment Document Number 104-0404-000010-011 Wiley Electronics LLC. 2006-2009© — All Rights Reserved WEEB COMPATIBILITY The WEEB family of products can be used to bond anodized aluminum, galvanized steel, steel and other electrically conductive metal structures. Standard Top Down Clamps The WEEBs used for bonding the PV modules to the mounting rails are compatible with various cross-sections of module frames. The following are examples of module frames that are compatible. Notice that the WEEB teeth are positioned completely under the edge of the module frame. The WEEB-UMC is only compatible with module frames that have a reinforcing box structure, as illustrated below. The following is an example of a module frame that is incompatible with the WEEB. The WEEB teeth are positioned only partially under the edge of the module due to the lip on the top edge of the module frame. Not Compatible W. •3 Wiley Electronics LLC. 2006-2009© —All Rights Reserved Top Down Clamps for Lipped Modules The following are a few variations of lipped solar modules mounted with inverted U-shaped clamps. The low -lipped module requires use of the WEEB-DMC instead of the WEEB-UMC. Notice that the force which the inverted U-shaped clamp exerts is in line.with the WEEB teeth. Low -Lipped Module WEEB-UMC is not compatible with high lipped modules. The WEEB teeth are not in line. with the force of the inverted U-shaped clamps, with the result that the WEEB teeth do not embed properly. .'High -Lipped Module Wiley Electronics LLC. 2006-2009© —All Rights Reserved SYSTEM OVERVIEW Use WEEB-UMC to bond solar modules to module mounting rail II Use WEEB Bonding Use one WEEBL-6.7assembly Jumper to electrically per rail to connect system to connect mechanically equipment ground conductor spliced rails Important notes:; I.- Use general-purpose. anti -seize compound on fastener threads ,,when installing WEEBs. 2.:2 WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed, if reused. Y Wiley Electronics LLC. 2006-2009© —All Rights Reserved 0 WEEB-UMC ASSEMBLY IT/�l"iui Pre -assemble WEEB-UMC to mid - clamp assembly as shown. Pre - assembling WEEB-UMC to mid - clamp assembly will contain the small individual parts, reducing the . possibility of losing parts during installation. WEE Wiley Electronics LLC. 2006-2009© — All Rights Reserved Spring retention tabs hold WEEB-UMC and Drop in T -bolt and snap WEEB-UMC on to mounting rai Slightly lift solar module and slide WEEB-UMC and mid - clamp assembly into position. WEEB teeth will automatically be aligned under the edge of the module when mid clamp assembly is correctly installed. Impollrtant note: To correctly install mid -clamp assembly, ensure that the T - bolt is perpendicular to.the mounting rail and both'sides of the solar."modules are completely positioned against the mid clamp. Refer to WEEB compatibility page for illustrations. Wiley Electronics LLC. 2006-2009© —All Rights Reserved ® Important note: WEEBs are for SINGLE USE ONLY! Do not torque down if position of solar modules is not finalized. tighten fasteners to keep modules in place. fasteners Only slighty then position of solar nodules are finalized, irque fasteners to 10 -lb / 13.5 N -m using aneral purpose anti- �ize compound on Breads Wiley Electronics LLC. 2006-2009© — All Rights Reserved 0 WEEB-UMC LAYOUT EVEN NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-UMC C X R = 4 X 1 WEEB-UMC NEEDED = C X R= 4 X 1= 4 ODD NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-UMC C X R = 5 X 1 WEEB-UMC NEEDED = [C+1] X R = [5+1] X 1 = 6 Note: When replacing a single faulty module, also remove the . adjacent module which contacts the same �WEEBs as the faulty module. This will ensure that there are never ungrounded modules in the array. Wiley Electronics LLC. 2006-2009© —All Rights Reserved O WEEBLUG ASSEMBLE( WEEB teeth towards rail Slide bolt to desired position and slip bolt through WEEB-6.7 EB -6.7 Install WE=BL-6.7 assembly and torque fasteners to 10 ft - Ib / 13.5N -m using general purpose anti -seize compound on threads Important note: WEEB-6.7 that sits under the WEEBLug is for single use only. Ensure position is correct before tightening dawn. Wiley Electronics LLC. 2006-2009© — All Rights Reserved LJ I Wiley Electronics LLC. 2006-2009© — All Rights Reserved UMC SPLICE KIT ASSEMBLY �9 The flexible WEEB Bonding Jumper can be mounted in different ways shown below. WEEB SLr, ners to .5N -m eral nti seize i on threads rs to I ize treads Route WEEB Bonding Jumper as shown above if�edge of solar module lands between := two spliced rails. - Wiley Electronics LLC. 2006-2009© — All Rights Reserved V LAjiLeL Advancing Renewable Technology ACCAcme Cable Clips ACME Cable Clips simplify wire management and create a cleaner aesthetic to solar PV arrays. The clips are made of corrosion resistant stainless steel and are designed to prevent damage to cable insu- lation. The easy to install and remove design only requires a flat head screwdriver and can be reused, unlike zip ties. The universal design fits most modules and can hold one or two wires. • Made with corrosion resistant 300 series stainless steel • Dual wire compartments • Special tab for easy installation and removal with flat -head screwdriver • Designed to prevent damage to cable insulation • Sized for USE -2 cable (5-5.4mm) or PV cable (6.8-7.2mm) ACC Holds: 1 to 2 USE -2 wires or 1 PV wire DC Power Systems `. (800) 967-6917 www.dcpower-systems.com ACC- PV Holds: 1 to 2 PV wires Contact us at: 845.247.4708 www.we-lic.com 6 Product Data Sheet DU222RB SWITCH NOT FUSIBLE GD 240V 60A 2P NEMA3R Technical Characteristics SaVARE'D .�' 4y Schneider Eicc«rc List Price $353.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Number of Poles 2 -Pole Terminal Type . Lugs Type of Duty General Duty Maximum Voltage Rating 240VAC Wire Size #10 to #2 AWG(AI) - #14 to #2 AWG(Cu) Action Single Throw Ampere Rating 60A Approvals UL Listed File Number E2875 Enclosure Rating NEMA3R Enclosure Type Rainproof acid Sleet/lee proof (Indoor/Outdoor) Factory Installed Neutral No Disconnect Type Non -Fusible -------------------------- ---------------------------------- --------- --------------------------------------------------- --_-------------------------- -------------------------- Mounting Type Surface Shipping and Ordering I Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule DE1A GTIN 00785901491491 ----------------------------------------------------------------- Package Quantity ---------------------------------------------------------------------------- -------------------------------------- 1 Weight 4.7 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. ------------------------------------------------------------- Retumability ------------------------------------ ------------------- ..------------------------------------------------------------- Y Country of Origin MX As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. i Generated: 11/17/2011 17:11:35 O 2011 Schneider Electric. All rights' reserved. Schneider 1 VElectric