Loading...
13-0889 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA.QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT -BUILDING PERMIT Application Number: 13-00000889 Property Address: 48545 VISTA CALICO APN: 649-530-016- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL VOICE (760) 777-7012 ' FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: r CORNE WILSON 48-545 VISTA CALICO - LA QUINTA, CA 92253 Dater 7/24/13 Application valuation: 27000 _ , v V Contractor: Applicant: Architect or Engineer j SANTUCCI,' BUILDERS INC 72529 BEAVERTAIL STREET �� O� �. PALM DESERT, CA 92260 17 60) 57s-7 iso cF�pG� D Lic. NO.. 820801 - • . r. ------------------- • LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION _ hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with. - I hereby affirm under penalty of perjury one of the following declarations:. • . _ Section 7000) of Division 3 of the Busi ess and Professionals Code, and my License is in full force and effect. _ 1 have and will maintain a certificate of consent to self -insure for workers'. compensation, as provided ' License Cla s: B is nse No.: 820801 - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is - I/ issued. • Date:' L Contractor:!•1 (/:/ham t _ ./ I have and will maintain workers compensation insurance, as required by Section 3700 of the Labor t. - - /- Code, for the performance of the work for which this permit is issued. My workers' compensation t . v OW -BUILDER DECLARATION f - insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier GRANITE STATE Policy Number 51759994-12 following reason (Sec. 7031.5, Business. and Professions Code: Any city, or county that requires a permit -to - _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair, any structure, prior to its issuance, also requires the applicant for the - person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she islicensed pursuant to the provisions of the Contractor's State and agree that, if 1 should become subject to the workers' compensation provisions of Section - License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or ,rj,. 3 0 of. the Labor de, I shall forthwith ro ply with those provisions. - - that he or she is exempt therefrom and the basis for the alleged exemption.. Any violation of Section 7031.5 by l i q►�� _ : + any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: Applicant:xvw- •.(_ 1 •1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and _ - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The - . WARNING: FAILURE TO SECURE W ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND - and who does the work himself or herself through his or her own employees, provided that the - - DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). _ APPLICANT ACKNOWLEDGEMENT , (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the r 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - - property who builds or improves thereon, and who contracts, for the projects with a contractor(s) licensed 1.. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). ^ whose.. benefit work is performed under or pursuant to any permit issued as a result of this application, (-1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced - within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject - - • CONSTRUCTION LENDING AGENCY permit to cancellation. - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of theI certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ord' ances and state laws relating to building construction,,arrdd hereby authorize representatives . of this coun y to a er upon the above-mentioned p operty for inspection pses. - Lender's Name: Date: ! 1Sl nature (Applicant or Agent): - Lender's Address: . ' LQPERMIT f Application Number . . . . 13-00000889 Permit . . . ROOM ADDITION 2013 Additional desc . Permit Fee. . . . . 181.61 Plan Check Fee'. .00 , Issue Date . . . Valuation . . . . 0 Expiration Date 1/20/14 Qty Unit,Charge Per Extension 1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF 120.12 1.00 61.4900 EA MISC ROOM ADDN, ADDL 500 SF 61.49 ---------------------------------------------------------------------------- Special Notes and Comments 230 S.Q. FT. BEDROOM AND BATHROOM ADDITION TO DETATCHED CASITA. PER 2010 CALID BUILDING CODES. July 19, 2013 2:20:25 PM JJOHNSON. -----------------_-_------------------------------------------- Other Fees . . BLDG STDS ADMIN (SB1473) ------------- 2.00 HOURLY PLAN CHECK 122.50 PLAN CHECK, ROOM ADDITION 185.90 STRONG MOTION (SMI) - RES 2.70 Fee summary Charged Paid Credited Due Permit Fee Total 181:61. .00 .00 181.61 - Plan Check Total .00 .00 .00 00 Other Fee Total 313.10 .00 .00 313.10 Grand Total 494.71 .00 -.00 494.71 LQPERMIT - U I R^f -.'CVED ,,,, Bin # Permit # �b�m Project Address: Yf Sqf tl(f Qty of La Quinta -Building u Safety Division 0 3 P.O. Box 1504, 78-495 Caile Tampico 3 La Quinta, CA 92253 - (760) 777-7012 c�M�yv y°Fc� Building Permit Application and Tracking Sheet C,?1te,0 Owner's Narnc:b'k* e tv; lia h A. P. Number: 11,0 - 0 Address: Llfr YJ IN br e4 /f 6_0 Legal Description: o -f Ito 4b 9F? 14 7 7 Tr'? V* Contractor: QhA/Gd A, f le;(ekf 'City, ST, Zip: Telephone: 925'9,2 3 Y' UMONS: Address: Project Description: 130 f beoevo4i, City, ST, Zip: -144 Telephone: 7 7S' 7%%S7 ..... . . . . . . State Lie. # City Lie. #.. Aq Arch., Engr., Designer: ive tWlfh ft Address: V#f k City., ST, Zip: Pa/*, (ma Telephone: W �k Construction Type: Occupancy: Con State Lie. #: ) Alter Project type (circle one): NewKAddn Repair Demo Name of Contact Person: ai-f Sq. Ft.: 0 # Stories: / 1 # Units: Telephone I/ of Contact Person: 760 3V(s '7?5Z Estimated Value of Project: 7-2 71 APPLICANT: DO NOT WRITE BELOW THIS LINE Submittal Reqld Recld TRACKING PERMIT FEES Plan Sets Plan Check submitted 3Item Amount Structural Calcs. Reviewed, ready for corrections bkl Plan Check Deposit Truss Calcs. Called Contact Person L23113 1 Plan Check Balance. dop Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2'! Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing F Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correction /issue 24 1� Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees ?•1 • r3 lowt olo4oun i " CERTIFICATE OF COMPLIANCE N Desert Sands Unified School District Zq`''1EA oo .47950 Dune Palms Road Q BERMUOAOUNES r /� q r) RANCHO MIRAGE b Date 7/24/1. - La QUinta, CA 92253 INOIANWELLS ti NO. 31740%INDIO RECEIroPALM DESERT y 7 -8515 °'NTA Owner Lorne Wilson APN # 602-190-016 Address 48545 Vista Calico JUL 2.4" 2013 Jurisdiction La Quinta ,City La Quinta Zip CITY OF LA QUINTA Permit # ;Tract #COMMUNITY DEVELOPMENT No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 48545 Vista Calico 230 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Addition to existing casita At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping,,cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less f EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. , in the amount of $0.00 X 230 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt- Jerry Santucci Check No. Bank Name/Recipient of Certificate Telephone 760-578-7757 Funding Exempt By Dr. Gary Rutherford Superintendent � 61 ;Fee collected /exem d by 8 aGIlVrey Payment Recd' $0.00 ✓ �` na 'Signature q NOTICE: Pursu nt to Government Cod Section 6020(d) ), this will serve to notify you that the 90 -day approval period inwhich`'you may protest the fees or other payment identified above will begin to run fro a date on which the building or installation permit_ for this project is issued, or from the date on which those amounts are paid to the Districts) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original Building Department Applicant Copy - Applicant/Receipt Copy - Accounting BUILDING ENERGY ANALYSIS REPORT. PROJECT:. ` , •, '. Wilson Casita 'Vo& y 48545 Vista Calico La �Quinta, CA Project Designer: _ Curtis R. Shupe 72-880 Fred. Warino Drive, Suite A=5 Palm Desert, Ca 92260 760-346-7354 ',.Report Pre ared'b J&Z : P y' �' 032013 - - Joan D. Hacker CQtZo � Insu-form, Inc. 77810 Las Montanas Road Suite 201 ,D.%,0 _' Palm .Desert, Ca 92211' 760-345=1352 CITY OF LA QUINTA Date: BUILDING & SAFETY Dom. APP .., 7/2/2013 COVED FOR CONSTRUCTION ;. The EnergyPro computer program has been used to perform the calculations summarized i QbA elrort. fpr 'has a pmV and is authorized by the California Energy Commission for use with both the Residential and N; n 20088 ng n rds. This program developed by EnergySoft, LLC – www.energysoft.com. —EnergyPro 5.1 by Energ Soft User Number. 2655 RunCode: 2013-07-02T16:53:15 ID: wrl 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Wilson Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/212013 Project Address 48545 Vista Calico La Quints California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 647 Addition 230 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 417 Perim = 18' Existing Wall Wood Framed R-11 970 Existing Door Opaque Door None 40 Existing Roof Wood Framed Attic R-19 417 Existing Slab Unheated Slab -on -Grade None 431 Perim = 15' New Wall Wood Framed R-19 582 New Roof Wood Framed Attic R-38 321 New Door Opaque Door None 20 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (tM 26.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 24.0 0.710 0.73 2.0 none Bug Screen Existing Right (S) 32.5 0.710 0.73 2.0 none Bug Screen Removed Front (iM 32.5 0.710 0.73 2.0 none Bug Screen New Right (S) 6.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Packaged Air Condition. 12.0 SEER Setback Existing 1 Room Heat Pump 5.95 COP Room PTHC without Sic 10.3 EER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing Addition Ductless /with Fan Ductless n/a n/a WATER HEATING I %-'7 Ot . Type Gallons Min. Eff Distri�utlbg-DING & SAFETY D Statu WITION � r DATE Energ Pro 5.1 by Energ Soft User Number: 2655 RunCode: 2013-07-02T16:53:1 Page 3 of 12 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Wilson Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/2/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a -certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. CITY OF LAQUINTA -- VBUILDIN , m FOR CONSTRUC ION Ene Pro 5.1 6 Ene Soft User Number: 2655 RunCode: 2013-07-02716:53:15 DATrD: Pa e 44 12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Wilson CaSlta ❑ Multi Family m Existing+ Addition/Alteration 7/2/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 24.31 17.95 6.36 Space Cooling 203.64 170.77 32.87 Fans 44.86 39.25 5.61 Domestic Hot Water 42.21 42.21 0.00 Pumps 0.00 0.00 0.00 Totals 315.02 270.18 44.84 Percent Better Than Standard: 14.2 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (KJ 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (14 560 59 Fuel Available at Site: Natural Gas (N) 350 24 Raised Floor Area: 0 (E) 0 0 Slab on Grade Area: 848 (S) 790 6 Average Ceiling Height: 8.0 Roof 738 0 Fenestration Average U-Factor: 0.71 TOTAL: 89 Average SHGC: 0.73 Fenestration/CFA Ratio: 13.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 7/2/2013 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Curtis R. Shupe Address 72-880 Fred Waring Drive, Suite A-5 Name Z 3 City/State/Zip Palm Desert Ca 92260 Phone 760-346-7354 Signe Licens # Date Ene Pro 5.1 by EnerSoft User Number: 2655 Run Code: 2013-07-02716:53:15 /D: Page 5 of 12 0 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Wilson C8sit8 Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 7/2/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 417 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 294 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Living Door 40 1.450 None 270 90 Existing 4.5.1-A1 Existing Living Wall 326 0.110 R-11 0 90 Existing 14.3.1-A2 Existing Living Wall 390 0.110 R-11 90 90 Removec 4.3.1-A2 Existing Living Wall 350 0.110 R-11 180 90 Existing 4.3.1-A2 Existing Living Roof 417 0.049 R-19 270 0 Existing 4.2.1-A4 Existing Living Wall 200 0.110 R-11 180 90 Removec 4.3.1-A2 Existing Living Slab 431 0.730 None 0 180 New 4.4.7-A 1 Addition Wall 168 0.074 R-19 270 90 New 4.3.1-A5 Addition Roof 321 0.025 R-38 270 0 New 4.2.1-A21 Addition Wall 214 0.074 R-19 180 90 New 4.3.1-A5 Addition Wall 200 0.074 R-19 180 90 New 4.3.1-A5 Addition Door 20 1.450 None 180 90 New 4.5.1-A1 Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 16.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 2 Window 10.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 3 Window 24.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 4 Window 20.0 0.710 Default 0.73 Default 180 Removed Double Metal Clear Existing Living 5 Window 12.5 0.710 Default 0.73 Default 180 Removed Double Metal Clear Existing Living 6 Window 20.0 0.710 Default 0.73 Default 270 New Double Metal Clear Addition 7 Window 12.5 0.710 Default 0.73 Default 270 New Double Metal Clear Addition 8 Window 6.0 0.710 Default 0.73 Default 180 New Double Metal Clear Addition (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat I Wd Ove hang Left Fin Right Fin Len Hat LExt REA Dist Len Hat Dist Len H t 1 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.5 4.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 2.5 5.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 dnt i IIn i , c' & / Kr t V V - Ns LATE EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-07-02T16:53:15 Pa e 9 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Wilson CaSita Building Type Irl Single Family ❑ Addition Alone ❑ Multi Family © Existing+ Addition/Alteration Date 7/2/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Living Zone Existing Living 417 3,336 1981 Addition Addition 230 1,840 Totals 1 2301 4171 01 0 HVAC SYSTEMS System Name Qt . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 1 Central Furnace 78 % AFUE Packaged Air Conditione 12.0 SEER Setback Existing Addition 1 Room Heat Pump 5.95 COP Room PTA without Sid 10.3 EER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R-Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing Addition Ductless / with Fan Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name aty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.53 n/a n/a Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 v `� Q CIV S stem Na i, �PI p t . tfr `Pi1 i ie1{ef� cul. ilk. Qty. HP Plenum Outside Buried ❑ w C ❑ ❑FDE CO ❑ DATE Ene Pro 5.1 b Ene Soft User Number. 2655 Run Code: 2013-07-02716:53:15 Pae 7 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name _ Date Wilson Casita 7/212013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R - Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the re uirements of 10-111 (a). " 117: Exterior doors and windows are weather-stripped; all joints and penetrafions are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for lAulating Material: Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF'1 R Form. �_ * *§150(a): Minimum R-19 insulation in wood -frame ceilin ore uivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum.R-13 insulation in raised wood -frame floor orequivalent U -factor. ` 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. ° a §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: . 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or lass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor .air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water.heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the'setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. , §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the° tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated'per Standards Table 150-13: §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and E uation`150-A.• `'• - §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirementsandafds le 123-A. §150(j)3A: Insulation is rotected from dama e, includin'� that due to -sunlight, moisture, equip ..ment main ena egad_ v p §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor 3tarida�ntj6rjGebcIdA6•eniir I n conditioned s ace. 150(j)4: Solar water -heating s• stems and/or collectors are certified by -the Solar Ratinj and CeAificatiodn Coro io FO t EnergyPro 5.1 by EnergySoff User Number 2655 RunCode• 2013-07-02716.53.15 q Pa e 8 Lk - , 'T � ` ... _ ,mss '. VAS •�, �: R � ^. av, •a 3' �1 •• f , � q. � '. L•: - �'. ,t t. -'may °1. .i � � �^ •`- ♦ � ^ /� �' MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Wilson Casita 1 7/2/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation ,required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than -20 watt �fpo er,pey�lin�ar�fd��t T M illuminated cabinet. Y �l BUILDING & SA ' APPROVED FOR CONS UCTION EnergyPro 5.1 by EnergySoft User Number: 2655 Run Code: 2013-07-02T16:53:15 /D: Page 9 of MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Wilson Casita 1 7/2/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1.: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTPA &SAF BUILDING APPF� E® FOR CONS UCTION DATE Z4P EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-07-02716:53:15 Page 10 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Wilson Casita Date 7/2/2013 System Name Living Zone Floor Area 417 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,089 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 56,000 16,543 1,095 273 11,437 Total Output Btuh 56,000 0 Output Btuh/s ft 134.3 1,403 813 Cooling System 0 0 Output per System 36,000 0 0 0 0 Total Output Btuh 36,000 0 1,095 0 Total Output Tons 3.0 1,4031 813 Total Output Btuh/s ft 86.3 Total Output s ft/Ton 139.0 19,348 13,062 Air System CFM per System 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 1,300 Existing HVAC 22,554 10,695 56,000 Airflow cfm/s ft 3.12 Airflow cfm/Ton 433.3 Outside Air % 0.0% Total Adjusted System Output 22,554 10,695 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK I Aug 3PM 56,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions r Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 69 OF 69 OF 110 OF 110 OF Heating Coil Supply Fan 1,300 cfm 109 o F ROOM1 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm / 67 °F 79/67°F 63/62°F 63/62°F C I f Supply Fan k -A 1YUr EA QUINT Cooling Coil pp y � ETYDEF$!6 F 1,300 cfm E3i11LIJlNG & SAFISIC ��79 FOR C78 / 61 OF DATE EnergyPro5.1 by EnergySoft User Number: 2655 RunCode: 2013-07-02T16:53:15 /D: Page 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Wilson Casita Date 7/2/2013 System Name Addition Floor Area 230 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 344 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 12,000 8,411 321 152 5,679 Total Output Btuh 12,000 0 Output Btuh/s ft 52.2 0 0 Cooling System 0 0 Output per System 12,000 0 0 0 0 Total Output Btuh 12,000 0 321 0 Total Output Tons 1.0 0 0 Total Output Btuh/s ft 52.2 Total Output s ft/Ton 230.0 1 8,411 1 5,679 Air System CFM per System 300 HVAC EQUIPMENT SELECTION Airflow cfm 300 Mitsubishi Electronics MSH17NW 9,161 1,105 7,495 Airflow cfm/s ft 1.30 Airflow cfm/Ton 300.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 9,161 1,105 7,495 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 300 cfm 70 OF 70 OF 105 OF Heating Coil 105 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F Outside Air 0 cfm 78/63°F 55/54°F c Supply Fan Cooling Coil 300 cfm 7BDtIN SAFETY Q, 54TAk O N78/63°F 8/63°F --� EnergyPro 5.1 by EnergySoft User Number: 2655 Run Code: 2013-07-02716:53:15 ID: Page 12 of 12