BRES2015-0288, . e � . � I IIIIII "III IIII IIII
07
78-495 CALLE TAMPICO. VOICE (760) 777-7125
U
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT sCq/�/N�D INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 10/9/2015
Application Number: BRES2015-0288 Owner:
Property Address: 48570 VISTA CALICO TURNER RESIDENCE
APN: 602190021 48570 VISTA CALICO
Application Description: ADDITION OF 210 SQ FT OFFICE LCO LA QUINTA, CA 92253
Property Zoning:Application Valuation: $25,000.00
9 2015
Applicant: Contractor:
ROB PITCHFORD LA QUINTA BOB EDWARDS CONSTRUCTION INCOR
76622 COUNTRY CLUB OPh1ENTDEPARTIv!ENT 51-455 DESERT CLUB DRIVE
PAM DESERT, CA LA QUINTA, CA 92253
(760)777-8202
Llc. No.: 684857
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I he firm under penalty of perjury one of the following declarations:
9 (commencing with Section 70001 of Division 3 of the Busine d Professions Code, ( I have and will maintain a certificate of consent to self -insure for workers'
and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance
License Class) B License _r.
eNo.: 684857 of th�,yf�rk for which this permit issued.
� � I have and will maintain workers' compensation insurance, as required by
Dater Contractor: Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued workers' compensation insurance carrier and policy number are:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an *owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(=) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( I I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of -the work for which this permit is issued•(Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
CarrPolicy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions
gI
�of Secti 00 theL e, I shall forthwith
comply wi�th a provisions.
Da eD Applicant-
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a.result of this application, the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state lard lati to building
construction, and hereby authorize representatives ofWtntelon the
above-ment- ne property for inspection purposes.Dater r Signature -(Applicant or Agent
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0 $62.36
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
'AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.40
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
-PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for ADDITION: $371.73 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT'
PAID
PAID DATE
HOURLY PLAN CHECK -*YES
101-0000-42600
1.25
$87.50
$0.00
PAID BY
METHOD
'RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
1
$70.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT'
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT.
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
.101-0000-42403
0
$145.03
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT'
PAID -
PAID DATE
CONDENSER/COMPRESSOR
.101-0000-42402
0
$36.26
$0.00
PAID BY
METHOD .
i
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
- ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT •
QTY
AMOUNT
PAID
PAID DATE
FURNACE
101-0000-42402
0
$36.26
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION •
= ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE PC
101-0000-42600
0
$24.17
$0.00
PAID BY
METHOD.
RECEIPT #,.
CHECK #
CLTD BY
Total Paid for MECHANICAL: $120.86 $0.00
DESCRIPTION
ACCOUNT
QTY•
AMOUNT
PAID
PAID DATE
SMI -RESIDENTIAL
101-0000-20308
0-
$3.25
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $3.25 $0.00
TOTALS:$0.00
r'
Description: ADDITION OF 210 SQ FT OFFICE
ADDITIONAL
Type: BUILDING, RESIDENTIAL
Subtype: ADDITION
Status: APPROVED
Applied: 7/27/2015 PJU
Approved: 9/8/2015 JJO
Parcel No: 602190021 Site Address: 48570 VISTA CALICO LA QUINTA,CA 92253
Subdivision: TR 29306
Block:
Lot: 21
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $25,000.00
Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0
No. Unites: 0
Details: 210 SQ. FT. NEW OFFICE SPACE PER 2013 CRC CODES
Printed: Friday, October 09, 2015 2:09:11 PM 1 of 4J?
SYSTEMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
NOTE
JIM JOHNSON
8/13/2015
8/14/2015
NOTE
JIM JOHNSON
9/2/2015
9/8/2015
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
8/14/2015
8/14/2015
STRUC READY FOR CORRECTIONS 8/13/15.
RECEIVED
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
9/4/2015
9/4/2015
STRUC APPROVABLE WITH CONDITIONS - SEE TRANSMITTAL
RECEIVED
PLAN CHECK PICKED UP
ED VASQUEZ
8/14/2015
8/14/2015
ROB PITCHFORD PICKED UP PLANS FOR CORRECTIONS
PLAN CHECK SUBMITTAL
PHILIP JUAREZ
7/27/2015
7/27/2015
RECEIVED
Printed: Friday, October 09, 2015 2:09:11 PM 1 of 4J?
SYSTEMS
Printed: Friday, October 09, 2015 2:09:11 PM 2 of 4 CR
SYSTEMS
FINANCIAL
RECIEVED SECOND SUBMITTAL SLIP SHEETED NEW
INFORMATION
DESCRIPTION
ACCOUNT
QTY
CORRECTIONS IN REDLINES OK'D PER JJ,TITLE 24-S DID NOT
RESUBMITTAL
RECEIPT #
PHILIP JUAREZ
METHOD
8/21/2015
CT
8/21/2015
BY
ADDITION, EA.
101-0000-42400
0
CHANGE, NEW & OLD STRUCTURAL CALCS. CORRECTION
$0.00
ADDITIONAL 500 SF
SHEET .SENT TO YOUNG.
TELEPHONE CALL
JIM JOHNSON
8/14/2015
8/14/2015
ADDITION, EA
CALLED ROB PITCHFORD TO INFORM HIM PLANS ARE READY
0
$17.40
$0.00
FOR CORRECTIONS
TELEPHONE CALL
JIM JOHNSON
9/8/2015
9/8/2015
CALLED ROB TO INFORM HIM PLANS ARE READY TO ISSUE.
ADDITION, FIRST 100 SF
101-0000-42400
0
CONDITIONS
$0.00
CONDITION
DATE
DATE DATE
ADDITION, FIRST 100 SF
CONTACT -
0
STATUS
REMARKS. NOTES
TYPE
ADDED REQUIRED -SATISFIED
-
READY TO ISSUE
9/8/2015
PENDING
CHECKLIST
Total Paid for ADDITION: $371.73 $0.00
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE"
ZIP
PHONE .. .
. ..............
,,,, ..FAX .
..... EMAIL
APPLICANT
ROB PITCHFORD
76622 COUNTRY CLUB
PAM DESERT
CA
(760)346-2856
CONTRACTOR
BOB
EDWARDS CONSTRUCTION
51-455 DESERT CLUB
LA QUINTA
CA
92253
(760)346-2856
INCOR
DRIVE
OWNER
TURNER RESIDENCE
48570 VISTA CALICO
I LA QUINTA
CA
92253.
(760)346-2856
Printed: Friday, October 09, 2015 2:09:11 PM 2 of 4 CR
SYSTEMS
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CT
BY
ADDITION, EA.
101-0000-42400
0
$62.36
$0.00
ADDITIONAL 500 SF
ADDITION, EA
101-0000-42600
0
$17.40
$0.00
ADDITIONAL 500 SF PC
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
ADDITION, FIRST 100 SF
101-0000-42600
0
$171.14
$0.00
PC
Total Paid for ADDITION: $371.73 $0.00
Printed: Friday, October 09, 2015 2:09:11 PM 2 of 4 CR
SYSTEMS
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
FINAL*" BLD
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT.'
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY. '
HOURLY PLAN CHECK -
101-0000-42600
1.25
$87.50
$0.00
YES
HOURLY PLAN CHECK -
101-0000-42600
1
$70.00
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $0.00
BSAS SB1473 FTE--7-.
101-0000-20306
0
$1.00
$0.00
Total Paid .for BUILDING STANDARDS ADMINISTRATION
$1.00 $0.00
BSA:
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$0.00
1,000SF
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$0.00
1,600SF, PC
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
CONDENSER/COMPRES
101-0000-42402
0
$36.26
$0.00
SOR
CONDENSER/COMPRES
101-0000-42600
0
$24.17
$0.00
SOR PC
FURNACE
101-0000-42402
0
$36.26
$0.00
FURNACE PC
101-0000-42600
0
$24.17
$0.00
Total Paid for MECHANICAL: $120.86 • $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$3.25
$0.00
Total Paid for STRONG MOTION INSTRUMENTATION SIVII: $3.25 $0.00
TOTALS::400
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
FINAL*" BLD
Printed: Friday, October 09, 2015 2:09:11 PM. 3 of 4 CRE"
SYSTEMS
Printed: Friday, October 09, 2015 2:09:11 PM 4 of 4 CR
sysreMs
BOND INFORMATION
Attachment Type.
CREATED
OWNER
PARENT
PROJECTS
SUBDIR
ETRAKIT ENABLED
DOC
8/13/2015
JIM JOHNSON
SCHOOL FEES2015-
SCHOOL FEES2015-
0
REVIEWS
0288.pdf
REVIEW TYPE
REVIEWER
SENT DATE.
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
NON-STRUCTURAL-
2 WK
JIM JOHNSON
7/27/2015
8/10/2015
8/13/2015
APPROVED
CALICO.docx
STRUCTURAL - 2 WK
KATHRYN
SAMUELS
7/27/2015
8/10/2015
8/13/2015
REVISIONS REQUIRED
SENT TO YOUNG.
NON-STRUCTURAL -
2 WK
JIM JOHNSON
8/21/2015
9/4/2015
9/2/2015
APPROVED
0
STRUCTURAL - 2 WK
YOUNG
ENGINEERING
8/21/2015
9/4/2015
9/4/2015
READY FOR APPROVAL
-CONDITION
SENT TO YOUNG
Printed: Friday, October 09, 2015 2:09:11 PM 4 of 4 CR
sysreMs
BOND INFORMATION
Attachment Type.
CREATED
OWNER
ATTACHMENTS
DESCRIPTION
_ _
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
8/13/2015
JIM JOHNSON
SCHOOL FEES2015-
SCHOOL FEES2015-
0
0288.pdf
0288.pdf
DOC
8/14/201S
JIM JOHNSON
48-570 VISTA
48-570 VISTA
0
CALICO.docx
CALICO.docx
1ST REVIEW -
NEW CITY
DOC
8/13/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
0
TRANSMITTAL
2015-0288 (lst).pdf
1ST REVIEW -
DOC
8/13/2015
KATHRYN SAMUELS
STRUCTURAL
88 KS -02
BRES 2015 2015 02
0
COMMENTS
2ND REVIEW -
NEW CITY
DOC
9/4/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
0
TRANSMITTAL
2015-0288 (2nd).pdf
Printed: Friday, October 09, 2015 2:09:11 PM 4 of 4 CR
sysreMs
a
Iain #
- o
City, of La Quinta
Building 8z• Safety Division
P.O. Box 1504,'78-495 Calle Tampico
—;---Z 'La Quinta, CA 92253 - (760) 777-7012.
Building Permit Application and -racking Sheet
Permit # -
--'
Project Address U l Sr.� [' [b
Owner's Name: 1.1 . To
A. P. Number: ��OZ ! 90c) --7) (
Address: g—Q
Legal Description: '0�—?306
r
City, ST, Zip: Lfu QU& (*.
Contractor:r
. Q
Tele Z
Phone: S
Address:
Project Description: • -
City, ST, Zip:
-04 0 45,Q FT Q/
Telephone: Po . ne�
ele h 7� O
State Lic. # : -
City Lie. #;
}kselr.��f-ig7�T.;'•�Designer:
Address - 77-6 V �/�e�t►+.r,,
T
City., ST, Zip:cm t..
T ele h ne
P o . 6 z
Lic #• ............Sq.
Con struc o Yti n T e• ecu
P Occupancy:
P Y:
Project type (circle rcle one • New Add'n Alter r Re
Pair Demo
Name of Contact Person:'
Ft.: Stories: (
#Units:
Telephone # of Contact Person: `7 v 8
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd `
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cafes.
'L
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person "
Plan Check Balance
Title 24 Cafes.
Plans picked up
I
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
�.
Grading
IN HOUSE:-
7rd Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr,
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE, OF'COMPLIANCES�
Desert Sands Unified School District : Zaga 0
47950 Dune Palms Road y eeaµvaaoa`c� o
a aaacxoeai
La Qunita CA 92253
Date: 10/9/2015 ,
No.: 15-00043-1 .(760)771-8515
Owner: Turner Email:
Address: 48570 Vista Calico .. Jurisdiction: La Quinta .
City:. La Quinta Tract #:..
I. Type: Residential Addition < 500 Sq ft
Lot # Street No.. Street Name Sq. Feet APN Permit No.
48570 Vista Calico 210 602-190-021
Comments: Office Addition
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures.(spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
i.
mobile homes. It has been determined that the above-named owner is exempt from paying school -fees at this time due to the following reason:
j
Residential. Addition 500 Sq Feet or Less .
Exempt
This certifies that school facility -fess imposed pursuant to
i Education Code Section 17620.and Government, Code 65995 Et Seq.:
j in the amount of .$0.00 X .210 S.F. or, $0.00 have been paid forthe property listed above and that building permits
and/or.Certificates of Occupancy for this. square footage in the p�oposeclproject may now be issued.
- Fees Paid By- Exempt -Bob Evans Check No.
Bank Name/Recipienttifi
of Certificate Telephone: 760-777-8202.
Funding: Exempt.
ey: Or. Gary Rutherford
Superintendent
Fee Collected/ Exempted by: Sharo cGil Amount -Due: $0.00
L
Origikl Paymen4(sj Rec'd: $0.00
Neve Pent Rec'd: $0.00
ver/Under: $0.00
7i1. w % I
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will se' t notify you that the"90-day approval period in which you may protest the fees or.
other payment identified above will begin to run from the date; on whic a building;or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public.entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED. WITH EMBOSSED SEAL.
L 0TJf 1 <T ✓ rr,
3 '
ENGINEERING ° ` r ° ° ��
E '
'Letter of,Transmittal , ` t • ,
To:.City of La Quinta Today's Date:. 9-4-15'
78-495 Calle Tampico , City Due Date: 9-4-15
La Quinta, CA 92253 - ProjectAddress:`y _ 48-570 Vista Calico
.4 Attn: Kay Plan Check #: ,` ,BRES.2015-0288 '
-Submittal: �. ;❑ 1st ❑ 4th
L ..® 2nd ❑ 5th
a,
" ❑ 3'd . ❑ Other:
r We are forwarding: ®_ By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: - # Of Descriptions: Includes: # Of Descriptions: ,
Copies: Copies:
® _ :Structural Plans ❑.; 1 Revised Structural Plans
® 1-- Structural.Calculations i. ❑ =1 Revised Struct. Calcs
Truss Calculations Floor -
❑ 1 and Roof i El Revised Truss.
t ❑, Soils.Report❑ t k Revised Soils Report
Structural Comment List/
® 1 ❑ _ Approved Structural Plans
F Responses 3
�� �' ❑ Redlined Structural Plans _ . ' ❑.' " Approved Structural Calcs
❑ Redlined Structural Calcs '❑ Approved Truss Calcs
❑ Redlined Truss Calcs' _,❑ ..4 Approved Soils Report Y
❑ Redlined Soils Reports ® 1 Other: Slip Sheet
Comments: Structural content is approvable, pending the following: Per framing plan, the hip truss
adjacent to the existing'structure does not have an overhang. Revise truss calculation to exclude the '
extended top chord: Following revision; the EOR.shall issue a letter of review and approval to the Building
Official or affix shop drawing stamp on the truss calculations stating reviewed and accepted:
If you have any questions, please call.
A'
Time = 1 HR
•This Material SenFti for::',` x
❑ ' Your Files'*' , �' �• ' ® Per Your Request
:Y. ❑ Your Review❑ Approval -
❑ Checking 'El' At the request of:
` Other: ❑ Na.
VEUBy: Kathryn Samuels
F` Palm Desert Office : ® (760) 772-5107
Other: ❑ . - SEP -O+ 15'
'CITY OF LA'QUINTA:
:�, = COMMUNITY DEVELOPMENT .
Master Association for Rancho La Quinta
79-285 Rancho La Quinta Drive
La Quinta CA 92253
Phone: 760-777-8807 Fax: 760-777-.8961 .
www.rlgma.com ;
Date: October 07, 2015
George Turner
48570 Vista Calico
La Quinta CA 92253
Re: 48570 Vista Calico - Approval of Submission
Dear Mr. Turner,
The Architectural Committee reviewed your submission for'the` following: .
Office addition
Your submission as presented, is approved contingent on the following:
• Any damage to the common area caused during this construction shall be repaired by the Owner to the
6 satisfaction of the Association.
• Roof tiles on new construction must match existing roof tiles in both style and color.
• All work is to be done in accordance with all applicable requirements of governmental entities,
including the City of La Quinta and in accordance with all Homeowners Association
Architectural/Landscape Guidelines and governing documents.
• If required, a City of La Quinta building permit will be obtained and copy furnished to the Association
prior to commencement of work.
• No other structural changes are approved with this submission.
( Once completed, please submit a "Notice of Completion" and the Association's'Architect will schedule an
1 inspection so we can process your deposit for return.
If you have, any questions, please contact the onsite office at,"760-777-8807.
Since ly,
G "
Jamie
Architectural & Communications Manager
Master Association for Rancho La Quinta
i
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Turner Residence
48-570 Vista Calico
La Quinta, CA -92253
Project Designer:
Robert A..Pitchford Design and Drafting
77-622 Country Club STE O
Palm Desert, CA 92211
(7.60) 346-2856.
Report Prepared by:
Jon Scott
Scott Design and Title 24,. Inc,
77=085 Michigan Drive
Palm" Desert, CA 92211
(760) 200-4780UINTp►
SPAFEN DEPT.
Bu�Lo�NPR ED
AP uCTIoN
FOR CONS
Job Number:
Date: JUL 2 7 2015
7/6/2015 CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 6.6 by EnergySoft User Number. 6712 ID:
CERTIE"OF`COMPL"IANCE RESIDENTIAL PERFOF
Project me: Turner
Calculation Description: Title 24 Analysis
LIANCEOD
*aculation Date/Time: 14:04, Mon, Jul 06, 2015
Input File Name: Turner-Pitchford-15.xml
RF -01 -
1 of 7
GENERAL INFORMATION
®®w
ENERGY USE SUMMARY
01
Project Name Turner
045j
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 48-570 Vista Calico
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1 .
14
Total Cond. Floor Area (ft2) 210
15 A
Number of Zones 1
16
Slab Area (ft2) 210
17W(
Number of Stories 1-
18
'Addition Cond. Floor Area N/Av19I
Natural Gas Available Yes
20
Addition Slab Area (ft2) N/A
a°�a1.
Glazing Percentage (°/a) 28.6% -
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
Aft.�
02 This building incorporates features that require field testing and/or erification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shoawiNelow
` war E
SIV -
CFO
.0
Registration Number: Registration Date/Time:
` CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744
HERS Provider:
Report Generated at: 2015-07-06 14:05:05
®®w
ENERGY USE SUMMARY
045j
06
07
08
Energy Use (kTDV/ft2-yr)
Starirarard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
0.00
0.01
-0.01
0.0%
Space Cooling
260.61
245.70.
14.91
5.7%
IAQ Ventilation
"� 6.83
6.83
0.00
0.0%
Water Heating
78.12
75.53
2.59
3.3%
Photovoltaic Offset
�; �' —
0.00
0.00
—
Compliance Energy Total
�� 345.56
328.07
17.49
5.1%
CFO
.0
Registration Number: Registration Date/Time:
` CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744
HERS Provider:
Report Generated at: 2015-07-06 14:05:05
CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project me: Turner culation Date/Time: 14:04, Mon, Jul 06, 2015
,Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xmi
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
CF•RF-01
Page 2 of 7
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QIQ
• IAQ mechanical ventilation
Cooling System Verifications:
• Refrigerant Charge - ,tab'r '
HVAC Distribution System Verifications: • v - s,4 '41
• — None — '
Domestic Hot Water System Verifications: ted' s
—None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such asMdomestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
' Reference Energy Use °�� Energy Design Rating `; ", Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 554.84 x 537.35k- 17.49 3.2%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION'°
01
02
`� 03
04
05
_ 06
07
Project Name
Conditioned Floor Area (ft2)4
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Turner
210
- 1
3
1
1
1
ZONE INFORMATION -
01
02
03
04
05
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone #e
HVAC System Name
(ft)
Height
Water Heating System 1
Water Heating System 2
office
Condi oned
HVAC 11
210
9
DHW Sys 1
°0
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Stand r s -.2013 Residential Compliance Report Version - CF1R-06232015-744
HERS Provider:
Report Generated at: 2015-07-06 14:05:05
CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE*OD C*F-01
Project Dame: Turner ation Date/Time: 14:04, Mon, Jul 06, 2015 Page 3 of 7
Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xml
OPAQUE SURFACES
01
02
0326
04
05
06
07
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
NE Wall
office
R-21 Wall (W21.2x6.16)
15
- specify -
140
Insect Screen (default)
90
SE Wall
"office
R-21 Wall (W.21.2x6.16)
105
- specify -
150
30
90
SW Wall
office
R-21 Wall (W.21.2x6.16)
195
- specify -
140
30
90
Roof ,
office w
R-38 Roof Attic
210
ATTIC ��
01 02 03 04 ��" 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic office . Attic Roofoffice r Ventilated 3,67 0.1 0.85 No No
A
L71 J
WINDOWS 4.� -
01
02
0326
04
05
06
07
08
09
10
-
Name
Type
%W
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(ft2)
U -factor
SHGC
Exterior Shading -
6x5
Window
SE Wall (- specify -105) V
6.0
5.0
1
30.0
0.28
0.18
Insect Screen (default)
6x5 2
Window
SW Wall (- specify —195)VJ
6.0
5.0
1
30.0
0.28
0.18
Insect Screen (default)
OVERHANGS AND FINS
01
02
03 04�'q
05
06
07
08 09
10
11
12 1 13
14
Ovvirh ang
Left Fin
Right Fin
Left
Right
Window
Depth
Dist Up�f
Extent
Extent
Flap Ht
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R"
Bot Up
6x5
6
0.1
6
6
0
0
0
0
0
0
0
0
0
6x5 2
6
M-,1
6
6
0
0
0
0
0
0
0
0
0
Registration Number: Registration Date/Time: -
CA Building Energy Efficiency Stand`a ds - 2013 Residential Compliance Report Version - CF1R-06232015-744
y
HERS Provider: -
Report Generated at: 2015-07-0614:05:05
- -- CERTIE`OF COMPLIANCE -'RE;
Project ame: Turner
Calculation Description: Title 24 Analysis
RFORMANCE COMPLIANCE
Date/Time: 14:04, Mon, Jul 06, 2015
Input File Name: Turner-Pitchford-15.xmi
CF&F-01
Page 4 of 7
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
.V
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Name
Heater Element Type
Tank Type
• Cavity/ Frame: no insul. / 2x4 Top Chrd
Efficiency
Input Rating
R -value
2x4 Top Chord of Roof Truss @ 24
DHW Heater 1
Natal Gas
Roof Deck: Wood Siding/sheathing/decking
Attic Roofoffice
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
>
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
��
• Exterior Finish: Wood
R-21 Wall (W21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C,,,
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01 02 03 0-7 04 05 06 07
v
Name Zone Area (ft?) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated
Covered Slab office 236V 45 None 0.8. No
BUILDING ENVELOPE - HERS VERIFICATION
IN
01
00 03 04
Quality Insulation Installation (QII)
Quality Installation di Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required
N rkequired Not Required —
44c*
WATER HEATING SYSTEMS
IN
01
02 *% 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 - 1/1
DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
WATER HEATERS 410
01
02 ^(�
03
04
05
06
07
08
.V
Tank Volume
Energy Factor
Tank Exterior
Insulation
Standby Loss
♦�
or
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
DHW Heater 1
Natal Gas
Small Storage
50
0.61
40000-Btu/hr
0
0
0
.40
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-06232015-744
HERS Provider:
Report Generated at: 2015-07-06 14:05:05
CERTIE OF-COMPLIANCE---RESIDENTIAL-PERFORMANCE ' COMPLIANCE OD
Projecse: Turner C culation Date/Time: 14:04, Mon, Jul 06, 2015
Calculation Description: Title 24 Analysis .Input File Name: Turner-Pitchford-15.xm1
CF -ORF-01
Page5of7
WATER HEATING - HERS VERIFICATION
01
02
03
04
05 -
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
—
—
—
—
—
—
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
:Heat Pump System 1:::2
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
None
None
HVAC - HEAT PUMPS ss�i
01
02
03 04 �� ;� 05
06 07
08
09
10
Verified Airflow 4%
Airflow Target
Heating`
Cooling
Zonally
Multispeed
HERS
Name
Type a
HSPF/COPReap 47 Cap 17
SEER EER
Controlled
Compressor
Verification
Heat Pump System 1
DuctlessHeatPump
8 '
� 2000
` 11000
15
13
No
No
Heat Pump System
1 -hers -cool
v�
-a,-
HVAC COOLING - HERS VERIFICATION ^� '
01
02
W 03
04
05
06
Name
Verified Airflow 4%
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 17hers-cool
Not Required
—
Not Required
Not Required
Required
IAQ (Indoor Air Quality) FANS or a
01
02 4k NW
03
04
05
06
Dwelling Unit
0-
IAQ CFM*,®
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
32.1`
API
0.25
Default
0
Required
I
I
COOLING VENTILATION.
* W
01
02 03 04 05
Name
_ �`e Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans
WH Fan 1
61 0.52459 32 1
s�
Registration Number:�@�% Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744
HERS Provider:
Report Generated at: 2015-07-0614:05:05
CERTI E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE WOD f C*RF-01
Project me: Turner culation Date/Time: 14:04, Mon, Jul 06, 2015 Page 7 of 7
Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xm1
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT '
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc, `
7/6/2015
Address:
CEA/HERS Certification Identification (If applicable): F
77-085 Michigan Drive
City/State:
Palm Desert, CA 92211
Phone:
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT ��
I certify the following under penalty of perjury, under the laws of the State of California: e��
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility %t4hee building design identified on this Certificate of Compliance.
J! I certify that the energy features and performance specifications identified on this Certificate oPG,ompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Comp it ance are consiste P org on other plicable compliance documents, .
Worksheets, calculations, plans and specifications submitted to the enforcement agency�for approval with " uilding pe e .
Responsible Designer Name: 4
esp le Desi g
Robert A. Pitchford
Company:r
ate Si n
Robert A. Pitchford Design and Drafting
Address:Li
se:
'
77-622 Country Club STE O®�
City/State/Zip:
Phone: t •
Palm Desert, CA 92211 ,�,
(760) 346-2856 '
®$N1
. - 0
42
Registration Number X�N Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-07-06 14:05:05
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Turner Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
7/6/2015
Project Address
48-570 Vista Calico La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area.
210
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavi ft2 Special Features Status
Roof Wood Framed Attic
R38 210 New
Wall Wood Framed
R 21 370 New
Slab Unheated Slab-on-Grade
- no insulation 210 Perim = 45' New
Demising Wood Framed
R 13 210 New
FENESTRATION Total Area: 60FGlazing Percentage: 28.6 % New/Altered Average U-Factor: 0.28
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (E) 30.0 0.280
0.18 6.0 none Bug Screen New
Left (S) 30.0 ' 0.280
0.18 6.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Split Heat Pump 8.00 HSPF
Split Heat Pump 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC 1 Ductless/with Fan
Ductless n/a n/a
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnemvPro 6.6 by EnerqySoft User Number: 6712
RunCode: 2015-07-06714:07:43 /D:
Pae 10 of 18
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
corn liance
approach used. Exceptions may apply. Review the respective code section or more information.
Bung Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-11l(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFI R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ ] 50.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)] A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e) I B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
'150.0(h)2.
in
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)1A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
1/
4
i
1
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class 1 or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)]:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ I50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy 5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§I50.0(o)IA.
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
y
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§I50.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ I50.0(k)I B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I50.0(k)I C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§I50.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§150.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2.
§I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in ' 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
14
4
i
•
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, ' 130.2; ' 130.4, ' 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§I50.0(k)1 l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§1 50.0(k)12B:
i. Comply with the applicable requirements in § 110.9, §130.0, §130. 1, § 140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§I 10.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10 e .
§110.10 a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§I 10.10(d):
A copy of the construction documents or a comparable document indicating the information from §I 10.10(b) through §I 10.10(c)
shall be provided to the occupant.
§, 10 10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.I O(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
i
•
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
urner Residence
Date
7/6/2015
System Name
HVAC 1
Floor Area
210
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 198 3,160
Return Vented Lighting 0
Return Air Ducts 0
Return Fan 0
Ventilation 32 1,408
Supply Fan 0
Supply Air Ducts 0
TOTAL SYSTEM LOAD 4,568
COIL HTG.
Latent CFM
300 443
616 32
916
PEAK
Heating System
Sensible
Output perSystem 12,000
41120
Total Output Btuh 12,000
Output Btuh/s ft 57.1
0
Cooling System
0
Output perSystem 12,000
1,542
Total Output Btuh 12,000
0
Total Output ons 1.0
0
Total Output Btuh/s ft 57.1
Total Output s ftfTon 210.0
5,662
Air System
CFM perSystem
640
HVAC EQUIPMENT SELECTION
Airflow cfm
640
mitsubishi 6,200
3,820
7,495
Airflow cfm/s ft
3.05
Airflow cfm/Ton
640.0
Outside Air %
4.9%
Total Adjusted System Output { 6,200
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
3,820
Aug 3 PM
7,495
Outside Air cfm/s ft 0.15
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 70 OF
Outside Air
32 cfm Supply Fan
640 cfm
72 OF
70 OF 81 OF
Heating Coil
81 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 72/61
Outside Air
32 cfm
70/60°F
OF 72/61 OF 55/54°F
Supply Fan Cooling Coil
640 cfm
56.2%
55 / 54 OF
I ROOM_..
70/60°F
Energ Pro 6.6 by Energ Soft User Number: 6712 Run Code: 2015-07-06T14:07:43 /D:
Page 15 of 18
I ROOM LOAD SUMMARY I
Tumer Residence
System Name
HVAC 1
ROOM LOAD SUMMARY
Date
7/6/2015
Floor Area
210
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible I Latent CFM I Sensible
office New Office 1 198 3,160 300 198 3,160 300 443 4,120
PAGE TOTAL
TOTAL *
* Total includes
EnerovPro 6.61
198
3,160
300
443 4,120
198
3,160
300
443 4,120
ROOM HEATING PEAK LOADS
Project Name771612
Turner Residence -
ate
015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name New Office
Floor Area 210.0 ft2
Indoor Dry Bulb Temperature - 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
AT OF
46 =
46 =
46 =
46 =
Btu/hr
R-38 Roof Attic
210.0
0.0260
X
251
R-21 Wall (W 21.2x6.16)
370.0
. 0.0690
X
1,174
Low -E.28.18
60.0
0.2800
X
773
Slab -On -Grade
perim = 45.0
0.7300
X
1,511
X
=
X
=
X
X
X
=
_
=
=
X
X
-
=
=
=
=
_
X
X
X
X
X
X
X
X
=
=
y.
=
X
X
X
X
X
X
X
=
=
=
=
_
_
=
X
=
=
=
-
=
Page Total
/60] X 46
AT
X
X
X
X
another room
9.00 X 0.266
Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 210 X
Area
3,709
= 410
TOTAL HOURLY HEAT LOSS FOR ROOM 4,120
EnergyPro 6.6 by EnergySoft User Number: 6712 Run Code: 2015-07-06714:07:43 /D: Page 17 of 18
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Turner Residence
7/6/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
New Office
Outdoor Dry Bulb Temperature
112 OF
Floor Area
210.0 ff2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
(W) 210.0 X 0.0260
X
77.0 =
420
R-21 Wall (W.21.2x6.16)
(N) 140.0 X 0.0690
X
32.0 =
309
R-21 Wall (W.21.2x6.16)
(E) 120.0 X 0.0690
X
43.7 =
362
R-21 Wall (W.21.2x6.16)
(S) 110.0 X 0.0690
X
42.7 =
324
X
X
=
X
X
X
X
=
X
X
=
X
X
=
Page Total
1,415
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
6x5
(E) 30.0 X 14.5 +
0.0
X 30.4 =
435
6x5
(S) 30.0 X 14.5 +
0.0
X 22.0 =
435
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
870
Internal Gain
Btu/hr
Occupants
0.6 Occupants X 245
Btuh/occ. =
154
Equipment
210 Floor Area X 0.50 w/sgft
=
358
Infiltration: 1.064
X 0.94 X 8.66 X 42 =
362
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
3,160
Latent Gain
Btu/hr
Occupants
0 6 Occupants X 155
Btuh/occ.
=
98
Infiltration: 4.771
X 0.94 X 8.66 X 0.00523 =
202
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
98
EnergyPro 6.6 by EnerqySoft
User Number: 6712 RunCode: 2015-07-06714:07:43 ID:
Pae 18 of 18
CERTIR E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project ame: Turner
Calculation Description: Title 24 Analysis
Date/Time: 14:04, Mon, Jul 06, 2015
Input File Name: Turner-Pitchford-15.xml
CF•RF-01
Page 1 of 7
GENERAL INFORMATION
01 Building Complies with Computer. Performance f ° r�yp�.-
- ca .,tea A, � �+ 'fD,. , �J�,
01
Project Name Turner
03 This building incorporates one or�more Specpaf Feat es ihhown below M
y04
02
Calculation Description Title 24 Analysis
06
07
03
Project Location 48-570 Vista Calico
ft2-1g -
Standard Design
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 20134 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 210
15
Number of Zones 1
16
Slab Area (ft) 210
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) N/A
21
Glazing Percentage (%) 28.6%
COMPLIANCE RESULTS
01 Building Complies with Computer. Performance f ° r�yp�.-
- ca .,tea A, � �+ 'fD,. , �J�,
rl
02 This building incorporates featuresithat require fieldtesting'and/or44verification. by a. certified! HERS rater.underthe supervision of a CEC-approved HERS provider.
.0,*, �i ,v.- -*k" F# kf +a't. - 4k�.__.- *( $C 0A JAR 35 11..
03 This building incorporates one or�more Specpaf Feat es ihhown below M
y04
11 t_- to --> r- V� %..10 V t
L..Of C; W -A
Z�MZ
y
Registration Number: 215-N0184591A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-07-07 07:42:32
Report Version - CF1R-06232015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-07-06 14:05:12
-
ENERGY USE SUMMARY
y04
05
06
07
08
Ene g Use (kT#
ft2-1g -
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
pace H
0.00
0.01
-0.01
0.0%
pace Cc oji
O
260.61
245.70
14.91
5.7%
Q Vent i
go -n
6.83
6.83
0.00
0.0%
ter H
(q
78.12
75.53
2.59
3.3%
h tovolta*
t -n
—
0.00
0.00
—
Cor il liance 85t
345.56
328.07
17.49
5.1%
Z�MZ
y
Registration Number: 215-N0184591A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-07-07 07:42:32
Report Version - CF1R-06232015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-07-06 14:05:12
CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD `
Project ame: Turner Ca culation Date/Time: 14:04, Mon, Jul 06, 2015
Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xmi
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
C*RF-01
Page 2 of 7
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Refrigerant Charge
HVAC Distribution System Verifications:
-- None —
Domestic Hot Water System Verifications:
— None -- e
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included inntdothe �pe�rforrmannc compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated"by Title 24, Part 6'(such as°mestic appliancesland consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
RefeiencerEnergy User Energy Design Rating Margin 1 Percent Improvement
Total Energy (kTDV/f2-yr)*554.84N; # i 537.35 17.49 3.2%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Turner
210
1
3
1
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
office
Conditioned
HVAC 11
210
9
DHW Sys 1
Registration Number: 215-N0184591A-000000000-0000 Registration Date/Time: 2015-07-07 07:42:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-07-06 14:05:12
CERTI#E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD CF�RF-01
Project ame: Turner Ca culation Date/Time: 14:04, Mon, Jul 06, 2015 Page 3 of 7
Calculation Description: Title 24 Analysis
Input File Name: Turner-Pitchford-15.xml
OPAQUE SURFACES
01
02
04
05
06
07
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
NE Wall
office
R-21 Wall (W.21.2x6.16)
15
specify -
140
Exterior Shading
90
SE Wall
office
R-21 Wall (W.21.2x6.16)
105
- specify -
150
30
90
SW Wall
office
R-21 Wall (W.21.24.16)
195
- specify -
140
30
90
Roof
office
R-38 Roof Attic
6
0.1
210
6
0
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic office Attic Roofoffice Ventilated 3 0.1 0.85 No No
WINDOWS
01
02
04
05
06
07
08
09
10
01
_03 _ _
03
_
Multipli
Area
07
08 09
10
Name
Type
Surface (Orientat�onaAzimuth)Width
(ft)
~Height (ft)
er'
(ft2)
U -factor
SHGC
Exterior Shading
6x5
Window.,
SE Wall'( spe"cify�-105) - � *t
U 6.6 "W
�" X5.0 "-
0 14
X30:0
0.28
0.18
Insect Screen (default)
6x5 2
Window
SSW Wall("`specify —195) "�
6a
50
'
'30.0
0.28
0.18
Insect Screen (default)
OVERHANGS AND FINS
01
02
03
04
05
06
07
08 09
10
11
1 12 1 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
6x5
6
0.1
6
6
0
0
0
0
0
0
0
0
0
6x5 2
1 6
0.1
6
6
0
1 0
0
0
0
1 0
0
0
0
Registration Number: 215-N0184591A-000000000-0000 Registration Date/Time: 2015-07-07 07:42:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-07-06 14:05:12
CERTIE OF COMPLIANCE --RESIDENTIAL PERFORMANCE COMPLIANCE JWOD CF�RF-01
Projectte: Turner Ca culation Date/Time: 14:04, Mon, Jul 06, 2015 Page 4 of 7
Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xml
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Total Cavity
Winter Design
Input Rating
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
40000-Btu/hr
0
0
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofoffice
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16) I
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
tT
01 02 03
04 05 06 07
Name Zone Area (ft)
Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated
Covered Slab office y { 210' "'
7r
' . 45 None 0.8 No
. 4% A --101 it it 3!Fl— VKIZ 9F R 7f 'IF &r
BUILDING ENVELOPE -HERS VERIFICATION
tT
01:02
'03 R 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage ACH @ 50 Pa
Required Not Required
Not Required —
WATER HEATING SYSTEMS
01
01
02 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%a)
DHW Sys 1 - 1/1
DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61
40000-Btu/hr
0
0
Registration Number: 215-N0184591A-000000000-0000 Registration Date/Time: 2015-07-07 07:42:32 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-07-06 14:05:12
CERTIt*E OF M COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: Turner Ca culation Date/Time: 14:04, Mon, Jul 06, 2015
Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xml
CF•RF-01
Page 5 of 7
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
—
—
—
—
—
—
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
:Heat Pump System 1:::2
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
None
None
HVAC - HEAT PUMPS
01
02
03 04 05
06 07
08
09
10
Airflow Target
Verified EER Verified SEER
Heating
Cooling
Zonally
Multispeed
HERS
Name
Type
HSPF/COP Cap 4,7 Cap17
SEER EER
Controlled
Compressor
Verification
Heat Pump System 1
DuctlessHe�attPump
Ar 2000,11000 t
_
'1y 15 il3
No
No
Heat Pump System
1
��
t
-hers -cool
'�:'�r:►:�---�r_ .:�'IES,�:�.�:.�..:a;.`.,�,�-�.�:;,�raE.'!'.�;�w;:i�
HVAC COOLING - HERS VERIFICATION H F R P R 0 V-1
1 0
01
02
03
04 05
06
Name
Verified Airflow
Airflow Target
Verified EER Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1 -hers -cool
Not Required
--
Not Required Not Required
Required
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
32.1
0.25
Default
0
Required
COOLING VENTILATION
01 02 03 04 05
Name Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans
WH Fan 1 61 0.52459 32 1
Registration Number: 215-No184591A-000000000-0000 Registration Date/Time: 2015-07-07 07:42:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-07-06 14:05:12
- CERTI�CFE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD•RF-01
Project Name: Turner ation Date/Time: 14:04, Mon, Jul 06, 2015 Page 6 of 7
Calculation Description: Title 24 Analysis Input File Name: Turner-Pitchford-15.xml
Registration Number: 215-N0184591A-000000000-0000 Registration Date/Time: 2015-07-07 07:42:32
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-07-06 14:05:12
CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Ct&RF-01
Project ame: Turner ation DatefTime: 14:04, Mon, Jul 06, 2015 Page 7 of 7
Calculation Description: Title 24 Analysis
Input File Name: Turner-Pitchford-15.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-07-07 07:42:32
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted
to -the enforcement,agency,for approval _awi h this..building permit application.
Responsible Designer Name:
L11'L
Responsible Designer Signature:.
%ufv.�cai
Tim Scott
tC'm
Company:
Design Title
Date Signed: V E
Scott and 24, Inc.
2015-07 07 07:42:32
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N0184591A-000000000-0000 Registration Date/Time: 2015-07-07 07:42:32 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-07-06 14:05:12