13-0874 (BLCK)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
13-00000874
79625 VISTA CORALINA LN
600-020-054- - -
WALL/FENCE.
COMMERCIAL PARK
2500
Tiiy�l
VOICE (760) 777-7012
FAX (760) 777-7011
BUILDING & SAFETY DEPARTMENT'S INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/15/13
Owner:
LA QUINTA HOUSING AUTHO �
78495 CALLE TAMPICO
LA QUINTA, CA 92253
JUL 16 2813
Architect or Engineer:
WW"%'K a=M
Contractor: ICITY OF LA QUINT
OPTIMUS CONSTRUCTION IN FINANCE DEPT.
440 WESTERN AVE #202
GLENDALE, CA 91201
(818)550-8411
Lic. No.: 902939
" LICENSED CONTRACTOR'S DECLARATION
WORKER'S COMPENSATION DECLARATION - -
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with ,"
I hereby affirm under penalty of perjury one of the following declarations: _
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
,. I have and will maintain a certificate of consent to self -insure for. workers' compensation, as provided "
License Class: B ( „-/ s License No.: 902939
or by Section 3700 of the Labor Code, for the performance of the work for which this permit is -
:3 Yr
Date Contractor:" /yimJ - .
ssued.
Z_-1have
6 and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
'd / v ,.
Code, for the performance of the work for which this permit is issued. My workers' compensation
-- OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the -
Carrier "SCOTTSDALE INS Policy Number '041650658812 ..
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
persornin any manner so as to become subject to the workers' compensation laws of California, '
permit to file a'signed statement that he or she is licensed pursuant to the provisions of the Contractor's State -
'and agree that, if I should become subject to the workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
- 3700 of the Labor Code, I shall forthwith comply with those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
five hundred
�l�pp
any applicant for a permit subjects the applicant to a civil penalty of not more than dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
Dater' alit cant:
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds of improves thereon,
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND "
" and who does the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving -that he or she did not build or
improve for the purpose of sale.). -
APPLICANT ACKNOWLEDGEMENT
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
conditions and restrictions set forth on this application. -
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
1. Each person upon whose behalf this application is made, each person at whose request and for -
pursuant to the Contractors' State License Law.).
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
1 _ 1 I am exempt under Sec.- B.&P.C. for this reason
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
"
of La Quinta, its officers,, agents and employees for any act or omission related to the work being
"
performed under or following issuance of this permit.
Date: Owner:
2. Any permit issued as a result of this application becomes null and void if work is not commenced
• within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY
permit to cancellation. -
. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
I certify that I have read this application and state that the above information is correct. I agree to comply with all
work for which this permit is issued (Sec. 3097, Civ. C.).
stru tion, and hereby authorize representatives
city and county ordinances and state laws relating t5e�
"
of this county to enter upon the above-mentioned prspec on purposes.
Lender's Name:
'
iDate: ' 1� Signature (Applicant or Age
Lender's Address:
.
`J
—LQPERMIT
Application Number . . . . . 13-00000874
Permit . . .. WALL/FENCE PERMIT
2013
Additional desc .
Permit Fee . . . . 47.19
Plan Check Fee
.00
Issue Date . . . .
Valuation . . .
. 2500
Expiration Date 1/11/14
Qty Unit Charge Per
Extension
1.00 47.1900 LS MISC-WALL,
FIRST 100 LF
47.19
Special Notes and Comments
BLOCK WALL PERMIT - 30 L.F. OF 5 FT.
HIGH BLOCK WALL PER ORCO STANDARD, FOR
TRASH ENCLOSURE. 2010 CALIFORNIA
BUILDING CODES.
Other Fees . . . . . . BLDG.STDS ADMIN (SB1473)
1.00
PLAN CHECK, WALLS
60.06
Fee summary Charged Paid
Credited
Due
Permit Fee -Total 47.19
.0.0 .00.
47..19 ,
Plan Check Total :00
.00 -00
.00
Other Fee Total 61.06
00 00
61.06 -
Grand Total 108.25
-00 .00
108.25
. LQPERMIT - - -- - ---- -- -
5' TO DAYLIGHT
---I*—
J,
MIN. I
SLOPE
CONT.
ORCO STANDARD 6'- TO 8' CMU SITE WALLS -
2 TO J
C--=]— OPTIONAL FLAT CAP
DESIGN CRITERIA: PER THE 2010 CBC
F3 —mi
AND FOOTING DIMENSIONS.
1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF
2. ALLOWABLE LATERAL PASSIVE PRESSURE =,150 P01
3. GROUT STRENGTH = 2000 PSI @ 28 DAYS.
4. REINFORCING STEEL: GRADE 60.
ool
5. 1500 PSI MASONRY COMPRESSION STRENGTH - NO SPCC.
INSPECTION
6816, 6616, OR 6618 CMU
GROUTED ONLY@ VERT
STEEL
NOTES.,
1. CONCRETE BLOCK Sh4ti CONFORM TO ASTM C.90. WED&SLOCK
BLOCK SLUMP OLOCKAND SPErTFACE "MAREACCEPTA BLE -
'YDROP-INBAR
2 CONCRETE FOR F007TNG SHALL BE I PART CEMENT TO 2-112
PARTS SAND TO 3-1/2 PARTS GRAVEL HMA NWMUN OF I-112
GALLOAS OF WATER PER SACK. poRTLAND CDffivTqjALL cour-oRm
TO A5TM C 150 TYPE ITIV Fc = 2500 PST
#6 STD JOINT
ti
REINFORCEMENT @24- Ole
3 RETAfFORCING STEEL SHALL BE DEFORNfD AAD,CONFORM TO
(3 PLACES - 4 PLACES FOR 7'
ASTM A 615 GRADE 60 PROVIDE 48 BAR DIAMETER LAP
B' WALLS). USE 05 STV.
FOR SLUMP BLOCK '
4. REB AR R.SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN
.
WHICH rrlSLOC 4TM
tib
NOTE PROVIDE 04 DOWEL i-
vf4DROP-IN a4RATE4Ol
SIDE OF CONTROL JOINTS
S. CONCRETE BLOCK SHALL BELAYED INA RUNNING BOND
PATTERN WITH KW77CAL CONTINUrTYOF THE CELLS UNO.
ENDS OF WALLS AND @ WALL
HET IT 04U& -a
6. ALL BLOCK allS CONTAINING VERTICAL RES4R SHALL BE SOLID
GROUTED.
Z USE TYPES MORTAR PROPORTIONED USING A57N C 270 PART
N* DOWEL 01 CENTER OF
CEMENT TO 412 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND.
CMU.
GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE I PART
CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318 -
PEA GRAVEL IF WEATHER CONDITIONS ARE FA PORABLE AND BLOCK
UNOBSTRUCTED CELL SME IS sumaENT 70 ALLOW GOOD GROUT
FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW
VVT7HOUT SEGREGATION OF THE CON-q7UEN7S.
SEE CHART
9. BLOCKSTEfif N4YBE WEr-SET 1-112*INTO THE F0077NG WHILE
THE CONCRETE IS PLASTIC BLOCK STEM NA Y BE PLACED TO
EITHER EDGE OF THE TRENCH TYPE FOOTING
10 F0077NG MUST SEPOURED ON OR INTO UNDISTURBED
2
NATURAL SOIL OR ON COMPACTED FILL 'W77H A MINIMUM
MAK
COMPACTION OF 90%.
11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE
READY ATR COVOZETEANDALL REQUIREDSTER IS 775DINPLACE
SECOND DUPECUON TO BE VNFJV THE
REQUIRED PER TX4L IS IN
PLACEANDTHE &OLX
WALL ISREADY TOGROUr.
04 HORZ CONT
12. MAXIMUM CONTROL JOINT SPACING: 40'0/C 10' 01C FOR
WALLS TO BE MORTAR WASHED OR snicoo COATED.
5' TO DAYLIGHT
---I*—
J,
MIN. I
SLOPE
CONT.
2 TO J
SEE CHART FOR REQUIRED REBAR
F3 —mi
AND FOOTING DIMENSIONS.
CITY OF LA OUINTA
BUILDING &.SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
0ATE7//f'/J--2 - 13 Y
77NG DEPTH FOR 5' TO DA YUGlf
WALL WALL 0 WALL 0
mp I Fr. SETWO( 2 Fr. SET340e
2'6' 2'0'
2'0' -
I
b
CHART FOR 6' TO 8' SITE WALL W/ TRENCH FOOTING
WIND
MAX.
D
DESIGN
WALL
TRENCH
FOOTING
X' DOWEL
'Y' BAR
SPEED
HEIGHT
DEPTH
61 -0 "
2, -OR
#4@ 48" 0/C ID+2'-O"
#4 @ 48" 0/C
U U
4B' O/C FOR 6'
48" 0/C FOR 6'
w
SLUMP BLOCK
SLUMP BLOCK
Ln L
Lx#4@
6!-8.
2'-2"
48" 0/C JD+2 -0'
#4 @ 48" 0/C
Q
40- 0/C FOR 6'
40' 0/C FOR 6"
Z w
SLUMP BLOCK
SLUMP BLOCK
�w
CL
= N7'-4"
2',l:'"
#4@ 40O/C ID+2'-O'
#4 @ 40" 0/C
CL
N
32' 0/C FOR 6'
SLUMP BLOCK
32' 0/C FOR 6"
SLUMP BLOCK
U7 Z)
co
#4@ 32" 0/C I D+2'-0"
24' 0/C FOR 6'
24' 0/C FOR 6'
SLUMP BLOCK
SLUMP BLOCK
NU It: rVK 1 i7'" LUrvEY LYL(Ax USE 9" INCREMENT REBAR SPACING THAT
IS CLOSER TOGETHER THAN THE 16" LONG BLOCKSPACING. FOR EXAMPLE:
48" O/C SPACING FOR 16" LONG BLOCK REVERTS TO 45" O/C FOR
IB" LONG BLOCK, 40" FOR 16" BLOCK GOES TO 36" O/C FOR IB" BLOCK - ETC.
FDR 9DEYARD UTURN N WALLS WN&E
LIR MGESWALEOCLURES, A W LR00K
/44YLEFT OL? l SWALE LMADE PROI?DE
04 DOWN AND 04 DROPdN MR ON S"
SWOFTILEl9&0 KLLPALN-AS
& OWN.
iarsw6-
r4 D1ROP�N BAR
CITY OF LA QUINTA
A"nwama m
am w wi.m"es=z
M MADS
N Ao2 G1Yf.I1G'ASJC�1ldt9•
wtlYIDfXMY.WAANWUA'Y
CHM IIgR3GY.
M/R712 RWI. IAfIJdY •IRT'.0[ 71'
�mv.wae»avwrauvamrr
ffi
F0077NG STEP DETAIL
O�R4ftiS S r:0,. C.
4
u m
a 1— Ln "
C31925 A
ExP. 12-31-20(i
F O!- CA1-SFO
J
Bin #
City of La Quinta
-Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: 6QS "vtft..
Owner's Name:
A. P. Number: (,,o 0 - 0 D 0 - o S14-
Address:
Legal Description: C,,,N Ne.,-C40,L^-t os
Contractor: C.,,._
City, ST, Zip: L C.A. CN;tas-3
J C�.
Telephone:
Address:
0 a
Project Description:
City, ST, Zip:
r%
t&y,, -'W.4er
Telephone: I
State Lic.#: O a93
City Lie. #.-.
Arch., Engr., Designer:
Address: -too
City, ST, Zip:
Telephone: 14c" S n !>
Construction Type: Occupancy:
State Lic. #:
Project type (circle one ):C; Addln Alter Repair Demo
Name of Contact Person: ¢ h 0 sf�
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person: C-+;.--) %Ck S- - .0 S
Estimated Value of Project:47'5(4-'�q,
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Rec'd'
TRACKING
PERMIT FEES
Plan Sets
'Plan Check submitted
Item
Amount
Structural Coles.
Reviewed, ready for corrections
Plan Check Deposit
Truss Coles.
Called Contact Person
Plan Check Balance.
Title 24 Coles.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, readySgr to . rrectionsfissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue'
School Fees
Total Permit Fees
P
Subcontractor Meeting Minutes
:Q..N S-. T:.R::V:C::TA.,0'N��: :1:'N:.C.�•
Coral Mountain
-
Meeting
# 23 - 05/21/13
Distribution:
Name
Company
Phone
E-mail
x .
Joseph Rossi
Optimus Construction, Inc.
(760) 895-0544
JRossi@optimusconstruction.com
x
Marlon Areas
r Optimus Construction, Inc.
(818) 813-1755 ,
mareas@optimusconstruction.com
x
Jeff Curdes
Optimus Construction, Inc.
(818) 813-1008
icurdes@optimusconstruction.com -
Russ Miller
Al Miller & Sons Roofing Co.
(760) 250-7021
russ@almillerroofine.com
x
Matt Miller
Al Miller & Sons Roofing Co.
(760) 250-0068
4.
x
Juan Rosales
AA Gonzalez
(818) 968-7113
-
'z'
Hermilo Melyo
AMPAM Parks Mechanical
(310) 863-6651
-
x
Francisco Calderon
BMC
(760) 895-3286
X. -
Chris Hammer
BMC
(760)•578-3970 .
Allen Mugica
Hardy Windows
(714) 853-9356
Greg Johnson
James A. Shirley Construction
(760) 228-0447
admin@*ascinc.com ,4
'Jim Smith
James A. Shirley Construction
(760) 275-0124
Jonathan Ramirez
La Salle Electric
(760) 200-7027
jramirez@lasalleli�htine.net
y . x
Leonardo Reis
La Salle Electric
(760) 409-7876
X. °
Wenceslao Razo
Lawson Concrete
(760) 275-1708
A.D. Flores
LDI Mechanical.
(951) 741-6783
Ismael Olivsa
LDI Mechanical
(951) 808-7161
c.
x
Juan Dimas
LDI Mechanical
(714) 589-9199
Dave Lippert
Lippert Construction
(760) 601-7437
dave@lippertconstruction.com
x
Joey Lanza
Lippert Construction
(951) 543-8293
'
Ken Phillips
Magik Glass & Door -
(760) 325-1876
'Andrew Hicks
Magik Glass & Door
(760) 272-4484
x
Juan Canizales
RWS
(909) 721-9974
Javier Cordova
Shasta Fire Protection
(760) 625-5908.
-
Michael Cordova
Shasta Fire Protection
(760) 219-4299
Everett Brunelle
Valley Wide Sheet Metal
(760) 275-3806
Bruce Brunelle
Valley Wide Sheet Metal
(760) 275-3812
x
Dave Dugan
VBI Doors
(760) 521-0004
Samuel Aguilar
VBI Doors
(760) 262-6315
-
(x)
Attendees
Next Meeting is on Tuesday, 05/28/2013 at 10:00 am at the Optimus Jobsite Trailer '
A. Safetv
Meeting
Item
Discussion
R/P
Status
001
001
HARD HATS and Reflective Safety Vest must be worn at ALL times.
ALL
Info
Each worker of ALL subcontractors must sign in individually each day. NO EXCEPTIONS. Please
001
002
make sure that you have the correct amount of total hours worked.
ALL
Info
ALL Subcontractors will provide Optimus with a copy of the weekly Safety "Tailgate" Meeting
001
003
Minutes every Tuesday at the Foremen's Meeting.
ALL
Info
001
004
No smoking or alcohol is allowed on 'obsite.
ALL
Info
All u con rac ors will cleanup aller ineir own worK and are responsible Tor jol5site trash an
general cleanliness. Please dispose of trash in a safe manner.
02-12-13 All trash material must be contain within the trash bin.
03-19-13 OCI stopped workers from throwing trash from the roof because they had no spotters or
caution tape below.
04-09-13 OCI stated again not to throw trash from the roof without spotters. Windows at Buildings
L & M were found broken.
001
005
05-14-13 OCI stated they found another broken window at Building G.
ALL
Info
001
007
All Subcontractors will respect the work of other subcontractors.
ALL
Info
001
008
Safety Compliance Orientation -Provided Upon Request
ALL
Info
Copies of OCI's Heat Illness Preventions Plan are available to all subcontractor's. OCI
recommends each subcontractor keep a copy of the plan on site.
001
009
03-12-13 Reminder: Each contractor to provide water and shade to their workers.
ALL
Info
All subcontractors on site have to provide all MSDS sheets for the products they are using on the
001
010
'obsite.
ALL
Info
All foremen are to check-in with the OCI Superintendent every morning.
001
011
Return all Sign -In sheets to the office by 2 m.
ALL -
Info
003
012
Each contractor must have their own First Aid Kit onsite.
ALL
Info
02-05-13 There are several overhead power lines that crosses dirt road (future A Street).ease
inform all workers and trucks of the danger.
03-19-13 More overhead power lines were added to the jobsite toward the South and East end of
008
015
the project. Please inform all workers and trucks of the added danger.
ALL
Info
03-19-13 Any contractor cutting holes on the 2nd floors and/or roofs must mark the holes they will
014 1
018
cut and warn all workers above or have an observer so that no one is accidentally cut from below.
ALL
Info
03-19-13 Please have all workers report any cracks or broken stair treads or handrails at
1
temporary stairs to OCI/BMC.
014
019
04-16-13 Do not use stairs without handrails.
ALL
Info
03-26-13 Bolts at the bottom stair landings will be painted o be more visible.
04-09-13 Bolts were painted orange to be visible.
04-23-13 Caps were placed on bolts at the bottom of the stair landings. The hole by building L stair
landing will be filled.
04-30-13 Rebar caps are being knocked off. Please re-insert them on the rebar if your men
015 1
020
accidentalIX knocked them off.
ALL
Info
ease clo not leave Nail Guns unattended and charged with air. Nail guns nee s
022 1
021
to be unplugged from air source when left unattendend.
ALL
Info
r
Week
No
Description
R/P
tatus
023
023
r0521-13 Temperatures will be in the low 100's this week with projected winds as high as 30 mph.
ALL
Info
C. Schedule & Deliveries w +
e
Meeting
Item
Discussion
R/P
Status
001
001
ALL Subcontractors will coordinate their project schedules and all deliveries with Optimus' Project
Superintendent(s).
ALL
Info
001
002
Please provide O timus with a list of all items delivered..
-view
ALL
Info
004
003
Fe two weeks look ahead schedule
ALL
Info
D. Current Construction Documents, , r
-Meeting
Item
Discussion
R/p
Status
016
153
Plan IndexMost current set is posted on OC jo site wall.
OCI
Oen
020
163
Please review the Plan Index with your current set of Construction Documents and inform Optimus
OCI
Oen
001
° .001-
Construction of any discrepancies. '
O timus '
Info
001
002.
SK's Sketches and Logs).,- Most current set is posted on OCI jobsite wall.
O timus ' ` _
Info
001
003
RFI Logs - Most current set is posted on OCl "obsite wall. -
O timus
Info
-001
004 "
Submittals Hard Copies and Los - Provided Upon Request .
O timus
Info
023
174
Every contractor onsite are to check if they are using the most current set of plans.
Lawson,
Oen
018
005
04-16-13 Revised Building K drawings Delta 7 -Owner Revisions .were,sent to all contractors.
O timus °
~. Info
176
-
05-07-13 Revised Building K drawings bathroom (Delta 8-2010 ADA Revisions) were sent to all
Oen
023
021
006
contractors. I t •
Opti Us
Info
022-
007
05-14-13 Delta 10, The Bathroom Door Flie were sent to all contractors on 5/10/13.
O timus
Info
05-2.1-13 RFI#179 Mailing Address Exhibit
OCI _
05-114713peita 9, The locations orn s & Hearing and VisuallyImpaired will e
022
008
sent to all contractors on 5/14/13. ` • . - + _
O timus , ..
* Info
E. RFPs y -
•sr
Meeting
Item
I Discussion
Involved
Status
016
153
04-02-13 RFI#153 Costco Plans & Specs
OCI
Oen
020
163
04-30-13 RFI#163 Method of Attachment for Formica Ceiling Tiles at Bldg K.
OCI
Oen
021
166
05-07-13 RFI#166 Signature Request on Sheet L-1
OCI
Oen
021
169
05-07-13 RFI#169 ADA Double Kitchen Sinks
AMPAM ` "
Oen
021
1 170
05-07-13 RFI#170 Double Locks Door Hardware
OCI, VBI •
Oen
022
173
05-14-13 RFI#173 Greenheck RFC -7 Installation Procedure,
LDI
Oen
023
174
05-21713 RFI#174 Resizing CMU Wall Footings -
Lawson,
Oen
023,
175 ` 05=21-13-RFI#175 Roof Hose. Bibon. Bld X-
AMPAM '
Closed
023
176
05-21-13 RFI#176. Door Strike Clearances at Unit Types A2 & C2
BMC
Oen
023
177 -: 05-21-13 RFI#177 FAU's Closet Door Thickness
VBI
Oen .
023
178'
05-21-13'RFI#178 Bldg Units Door Swap Confirmation - -
All
Oen
023-
179
05-2.1-13 RFI#179 Mailing Address Exhibit
OCI _
Closed
0p►
i
- ��MUCTQAU OV��,
� t rwE u "-
vvo� /Wq�vo,
I'- �I-kcwo,o
rA
1