Loading...
07-0258 (BLCK)4 4 Q P.O. BOX 150C" VOICE (760) 777-7012 78-495 CALLE TAMPICO t FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 , BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 1/24/07 Application Number: X077.00000258� _I Owner, Property Address: 80801- VISTA`LAZO LEE STIRRETT APN: 762-250-017 - - 50325 VIA AMANTE ' "Application description: .WALL/FENCE LA QUINTA, CA 92253 G Q Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 5050" �. t �. .SAN 24 ZO07 - ,Contractor: , Applicant: Architect or Engineer: Owner C"'YOF Aw E DEPT TA ------------ ---------:-•------ -- ;. _— — — — — — — — - — — - — — — — — — — — — — — — — — — — — — — -----—-------—----------—---——---------—------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COM PENSATIONDECLARATION . I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: - Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: License No.: - for by Section 3700 of the Labor Code, for the performance of the work for. which this permit is - ' issued. .. Date: Contractor: - - _ I have and will maintain workers' compensation insurance, as required by Section 3700 •of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation - OWNER -BUILDER DECLARATION - insurance carrier and policy number are: " I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier Policy Number following reason -(Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the work for which this permit is issued, I shall not employ any ' construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner as to become subject to or s' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I s uld b e subject to t r ompensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Coder or 3700 of the Labo C de c , hose pr that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: 'Date: ! App it nt: (z) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: AILURE TO S E WORKERS' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100;000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. rY one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License -Law.). whose. benefit work is performed under or pursuant to any permit issued as a result of this application, (_{ I am exempt under Sec. , B.&P.C. for this reason the ownei, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. r 'Date: /Owner• 2. Any permit issued as a result of this application becomes null and void if work is not commenced r CONSTRU ON LENDING AGENCY within 180 days from date of issuance ofsuchpermit, or cessation of work, for 180 days will subject permit to cancellation. �ereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the o oe information is co ct. a to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to bu' ding cons on, reb ze representatives of this county to enter upon the above-mentioned pro y r ' cti Lender's Name: - �,;/ f _ � � `_ - - - ; Date 1 - �' Signature (Applicant or A U: Lender's Address: �' L��.Y— LQPERMIT, . • Application Number . . 07-00000258 Permit WALL/FENCE PERMIT ' _ Additional desc . _ Permit Fee 81.00 Plan Check Fee .00 Issue Date Valuation 5050 Expiration Date 7/23/07 - Qty Unit Charge Per Extension BASE FEE _ 45.00 4.00 9.0000. THOU BLDG 2,001-25,000 36.00 Special Notes and Comments 202 LF 6' BLOCK WALL.PER,CITY STANDARD _ Fee summary Charged Paid Credited Due Permit .Fee Total 81.00 .00 .00 81.00 Plan Check Total. .00 .00` .00 0'0 Grand Total 81".00 00 .00 81.00 i LQPERMIT .. .. Bin # City of La Quints Building a Safety Division P.O. Box 1.504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # r' eol Project Address: _ D / /jT Zv Owner's Name: L EE7 ,F::: A. P. Number: g5 2-- 2- % - / 7 Address: b TC Legal Description: T / 7 p G-7— 2-r-,70 City, ST, Zip: Contractor: L 0"11e) Gi C _ Telephone: 7l:/ — 6.1— 5P5 Address: Project Description: City, ST, Zip: ,q ex) r �D f�E 5T iDE o Telephone:/�- State Lic. # : City Lic. #:. > - 7z';, e::P4CCo Arch., Engr., Designer: Address: D �� City, ST, Zip: oZD 2 C.F 6/ Telephone: j r _ Construction Type: C,0,141 Occupancy: State Lic. #: Project type (circle one) New Add'n Alter Repair Demo Name of Contact Person: 7 T Sq. Ft.: / Z 6 # Stories: # Units: Telephone # of Contact Person: 760 - - C?57P Estimated Value of Project: 4'/ 2 00 (0, - APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Ree'd TRACKING. PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Cafes. Called Contact Person Plan Check Balance Energy Cafes. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading. plin 1" Review, ready for corrections/issue Electrical Subcoutactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Pians resubmitted Grading IN HOUSE:- '"' Review, ready for. correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees OF QCITY LA VITA . BUILDING AND SAFETY DEPARTMENT GARDEN WALL STANDARD C-M.U. ' 40001350psi, Fy=6' fm= 0psi #4 0 24" Vert 0 CL y4 0 32" Horiz I o - iq I .. . 6 1/4"' A RNATE BEN 3" CLEAR -7�- #4 HORIZ. AS SHOWN .1 �I V-6" 6' c .6' C.M.U. f*m= 1350psi. F.y-- 40000ps1 #4 0 24' Vert 0 CL d4 0 32' Horiz GARDEN WALL " � 1 a . in Scole: 3/8' i,_0. `a 6' C.M.U. f•m= -1350psi, Fy= 40000psi ' A4 0 24' Vert 0 CL Y. CLEAR T c ' /4 0 32 Horiz X74 HORIZ. AS SHOWN Z' I ` 00P .. 10-11./16. . OPTI AL 30'LA �5 G RDEN WALL `f r it• r ly.a. ALTERNATE 3" CLEAR _ Score 3:/$ t� #4' HORIZ. As SHOWN T BENDS oI 6` C.M.U. 2 -Q" f m6 1350psi, Fy= '44000psi y4 0 24'. Vert' ®CL #4 0 32' Horiz S' GARDEN WALL cc .I `, X. Seale 3/f3" , _D• .- fi. C M Aj _ .. J PTIONAL� 30'LAP fm 935Opsi, Fy=' 40000psi " v 0 34" ;Vert .0 CL j �:4 0 32 `Horiz 3' CLEAR .: '.: .4. 04 HORIZ. AS SHOWN - T 2'-6' ! O.NAL. 10=11%16' 3(7_..' a / .. (P GARDEN . WALL .. 3" CLEAR ALTERNATE Stole: 3/6" ' #4 HORIZ. AS SHOWN 'I BENDS'.. --.,-GARDEN WALL:. Scale: 3/8" = V• n" I ORCO block TEK's Average Weight Fite Resistant MasonryWalls Fire Ratings Sound Control Sound Absorption 8bck Calculation Table Grout Requirements 7HH11 DETAILS s� Page 1 of 2 fR1/YV�Ii SAWIVULLEU I�RRJK I�Y�fiiAllrt�liiMi - L ky t • . T ,Inc777.7 1. COMMON BOND 2. COMMON BOND 8" high and 16" long units �4" high and 16" long units h ://www.orco.com/tech wall.htm T 1/22/2007 ttP _ . Joint Details 1. STACK BOND_ ., 8" high and 16" long units 2. STACK BOND " �• r 4" high and 16" long units Wall Patterns Mortar Joints Typicol Details Comer Details Vertical Steel Placement7. 4 Connection of Intersocting Walls ,• - , Conaatre / Masonry Pilasters , Door g Window Untei 3. STACK BOND 4. STACK BOND Floor & Roof 8" x 16" and 4" x 16" units " , 8" x 16" and 4" x 16" units Connection = ` Typi�o! Control Joints Parapet Details Sample-Typpt�ool •y - � `' Retaining Walls 7 _ Retaining Wags- 6,100 Tr - S. STACK BOND , , 6. STACK BOND - . t 8" x 8" units r . 8" x 16" and 4" x 16" units '�Jil.- ky t • . T ,Inc777.7 1. COMMON BOND 2. COMMON BOND 8" high and 16" long units �4" high and 16" long units h ://www.orco.com/tech wall.htm T 1/22/2007 ttP _ . ORCO block �i µ, Page 2 of 2 a }�..a •j .. - Ch �• •i''.a•r j.YS •�iF .F .' '' � - ' Y .- � A. .d i' -v ! _..y S.+ is .!•: _ � , . "1 � - •.i .. i �• *' f 15518"' y■ z 1`` ! 6X8X8 �, u • .. i7518' ' , ;Half- µ 6x8x16`'t .`t c �'" 750�_ 1 -7. k j ■� star ` ., t5 " 50,11r y s f n�� ''"5 r A`�• I ' '` ;-+ 6%8X16' I�jj� II to ' Corner Return J -6. " 15 5181,� t" + J " .17 5 �- 2 12" 6x83X14 ` f .Corner " � u i4tv Y-13 518" 6%8x16 8B s ' 6 8 Half ,17 518 1 r _ .1•- > .. ..- 6%8X15 a s �. �• ? j 'Corner L E] 6%8X18 �---14 58;'—•� r ' . • � .. � � .Y r a• i{ a I{• _ .. - :.vr. �.ShVr ; .1a ._ For exact configurations 8 dimensions of cores please consult your Architectural Representative. . o . contact us: info@orco.com ORCO i What's, New iI Locations I Links i E -Portal i Calendar i Contact Us I Home A Products I Resale.Products I Technical. Notes 8 Details I Specifications I Design Center I Dealers i Masonry Gallery " r ,+• Copyright O ORCO 2004 ' II' � '`.r .. � ..r-. "d � f 4i,1 .0-.. r � y�+ • s' - •ry^�_ ._ Y .. [ _ t , •r y • • , _, ,. 4 [ u s F ! � � N R-�� - F r ` � r •.c e . y � � ��1r t. ; ,. j , ,.� - - = i :sem .. _ ' - �:�' 67 rJ v`»� fes. � �..• � Q �� " -:•r,. t' ,-_ .. �°+ ter• �G� �; � ,i ,f -u - .. .. f`a , h4://www.orco.com/pr=pfecis.8h.htiri`!. } . `` � `= , 1/22/2007 `` ORCO block ORE1 .ir',. s syr ' 4 `- '•�` I s lop :1 d�1JeL711:rtd �' '�. ►_ / ,anvil Ownad 5rnea,184 Page 1 of 1 • nuumKIM&MAM tea, AUiNRRIi� DEAtERt iAASE?IIR�f@AILF� ' Spec AIDE SPECIFICATIONS FOR CONCRETE MASONRY (Short'Form) Conaete Masonry Unit HI -STRESS MASONRY Conacte Masonry (short fOfRl) Hi -stress masonry cost more than the regular A.S.T.M. C-90-96. Be sure to specify the fm required. If OKO WAIL SYSTEM you want a 3,000 P.S.I. fm you will need a block with a minimum P.S.I. of 3,570 a grout with a 4000 P.S.I. and a type M mortar. _ SPECIFICATIONS FOR CONCRETE MASONRY -SHORT FORM - - Masonry Units shall be type II units conforming to A.S.T.M. C-90-96 and in addition the requirements • of the Quality Control Standards of the Concrete Masonry Association of California and Nevada, manufactured by ORCO BLOCK. ,Texture (Precision; Split Face; Slumped) Orco color or approved equal. , PORTLAND CEMENT shall conform to A.S.T.M. C7,150, UBC 19-1 ' Y • • MORTAR shall be freshly prepared and uniformly mixed in the ratio by volumes, 1 part cement, Y2 - r • _ part Hydrated Lime; 3 parts sand, and shall conform to A.S.T.M. C-270, UBC 21-15 mortar to match color of block. r r GROUT shall be a fluid consistency and mixed in the ratio by volumes, 1 part_ cement, 3 parts sand, ,or 1 part cement, 3 parts sand, 2 parts pea gravel. REINFORCING STEEL shall be deformed bars conforming to A.S.T.M. A-615 except that 1/4" ties may be plain bars. Wire reinforcement shall conform to A.S.T.M. A-82. Walls shall be laid true and plumb. Provisions shall be arranged for all adjoining construction.. Construct a 4'x6' sample for workmanship, joint treatment, pattern and color of mortar for approval. Tuck point all holes 1/8" or more. - click here to download the file y~- _ •y ' ` ' ! �_* Contact us: info@orco.PAITI' ' About ORCO I What's New I Locations I Links I IE -Portal Calendar I Contact Lls I Home . ^ Products I Resale Products 1 Technical Notes & Details I Specifications I Design Center I Dealers I Masonry Gallery. , "Copyright O ORCO 2004 • `�" ` is . - i - � +- '� - to w � '� , • 7 - � • � r �' t - http://www.orco.com/specific_cm.htm,_ . •+ ' r . ~ ' 1/22/2007