BRES2014-1143C aNN1��il/
`•Cf/ '�/
VOICE (760) 777-7125
78-495 CALLE TAMPICO
FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253
COMMUNITY DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 1/21/2015
Application Number: BRES2014-1143
Owner:
Property Address: 80871 VISTA LAZO
JACLIN C. SMITH
APN: 762250010
302 E. WEDGEWOOD
ns-
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed'under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 769229 ,
Date: / At m; Contractor'
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, -the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to w
the Contractors' State License Law.).
(� I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
(760)771-9954
Llc. No.: 769229
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of th#wprk for which this permit is issued.
1 have and will maintain workers' compensation insurance, as required by
Section 1700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with hose provisions.
Date: r Zi ? Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and.the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above•
mentioned property for inspection purposes.
Date: I !1 f , Signature (Applicant or Agent):
FINANCIALe•
e
�F DESCRIPTION;,a3
t ACCOUNTS �
aQTY AMOUNTa
s PAIDr
PAID DATE
oz
<�
. 3
,w,;
ART IN PUBLIC PLACES -,RESIDENTIAL
270-0000-43201
0
$382.17
$382.17
1/15/15
`PAID BY #
,iz.�METHOD�'
'. RECEIPT#� e,�
CHECK#
CLTD BY411
y e#a
,
c'
JACLIN C. SMITH
CHECK
R3425
7021
AZA .
Total Paid forART IN PUBLIC PLACES - AIPP: $392.17 $382.17
g $ `=: DESCRIPTION �' `���° ��
� °` �� � ACCOUNT � � {{
�CtTY
��� AMOUNT�e
'18` � PAID*';� a
PAID DATE:
f'
<„is„r
',;,.
BSAS SB1473 FEE
101-0000-20306
0
$15.00
$15.00
1/15/15
PAID<BY' t
44 ,,
RECEIPT,#
Mkt....
CHECK # '
CLTD
1
w .'METHOD �.a
,
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $15.00 $15.00
S� DESCRIPTION: fzq "
r ' tACCOUNT "�iii
Y`CtTY
'AMOUNT
PAID
PAID DATE:
f DIF - CIVIC CENTER
252-000043200
0
$942.00
$942.00
1/15/15
1 { b °iSx {•'i+'k� Y A �• :. 4 Hi C
PAID'BY
sY S 3R. p,k yi - .- was
k aMETHOD
.'R .� .1..
ECEIPT:
CHECK
BY
�z
s< �'� _ .L x
R
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTIONP
}ACCOUNTz
w,;QTYf
w 'AMOUNT s
*z,s? PAID
PAIDDATE
_@ t".2 if
ff' G uS.�e °Il.i
f a 7•,( Sr. a`
�! .%
a.ji(
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
$129.00
1/15/15
INr,
z; PAID'BY cam,;$ r�
?s
METHOD `�,
,.
* ;.RECEIP,T;#
,.
* aCHECK#+z
C LT D BYE
°..�u <� '�•f .r .•- ..
.� ��s _ a.,:,
.�>x.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
F`
,r ACCOUNT
QTY
"_� AMOUNT a"z9
'r. PAID
PAID DATE:
a ,DESCRIPTION
.
DIF -FppIRE PROTECTION
257-0000-43200
0
$433.00
$433.00
1/15/15
G L� S
a > PAID BY hz P,
L, S+�
;! y METHOD
f S.wUr
RECEIPT # f
•14
CHECK # '
y.a:
CLTD BY >'
a
F w
n,< t.• tr
JACLIN C. SMITH
CHECK
R3425
7021
AZA
t
a '.
; ACCOUNT .,
QTY
AMOUNT��
' PAID
PA D'DATE
r`& rDESCRIPTION a , t.
ems;s�,•c
4
, ,
DIF - LIBRARIES
253-0000-43200
0
$344.00
$344.00
1/15/15
PAID BY,{
�r s METHOD
_ RECEIPT #�-
CHECK # "'
CLTD BY
_
Jf
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Y � DESCRIPTIONA,f:"
" s ACCOUNT
F.CZTY
AMOUNT
r PAID
4PAID'DATEa
p
:`
DIF - PARK MAINTENANCE
'256-0000-43200
0
$40.00
$40.00
1/15/15
"fz Q.PAID BY'a 3
x` METHOD
k RECEIPT,# a �f
! Y CHECK
CLTD BY
,ry
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTION E _ ��.�
rACCOUNT 3z
QTY=F
"AMOUNTAN'
z PAID j
PAID DATE
;fir
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
$2,048.00
1/15/15
PA16
�
;H
RECEIPT#
CHECK#
CLTD
BY
JACLIN C. SMITH
CHECK
R3425
7021
AZA
` zfaDESCRIPTION * `
�j a 1, `ACCOUNT rt?� z,
QTY
`;, AMOUNT°
t� PAID x
PAID;DATE;;
+
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
$116.00
1/15/15
PAID BY i
4 _ ` METHOD '`
+ n'RECEIPT # z
CHECK# �.
CLTDBY
s _ ,> r:;•.-°:_...
.- .,.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
r$ DESCRIPTION �'
" <:ACCOUNT a
'QTY
AMOUNT` '"�
z r�' PAID '
PAID DATE:
>. a
E_ r.
DIF -.TRANSPORTATION
250-0000-43200
0
$2,842.00
$2,842.00
1/15/15
L
}
,
5,4 h�'�PAID"BY --METHOD
RECEIPT#
z CHECK#="
�'CLp TDBY
¢:
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total Paid forDIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00
M ?DESCRIPTIONS a;,
ACCOUNTt
s°{€`AIIIIOUNTh
PAID,
PAIDDATE'
.i .F°Yiy.G..<:' i• fix... -. �y..-...+a+`� r'
`'K b r.e , VY
;QTY
TEMP POWER SERVICE
101-0000-42403
0
$24.17
$24.17
1/15/15
Y F 4 �
PAID BY4
��,��S * 'S 'T 3 � �'.,.'§y
METHOD
is � 't '+r -. t '4 .'�. -- �.
`RECEIPT #
Y{. ':T
CHECK #
CLTO BY
...�, ,
4
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTION . $
t ACCOUNT >3
QTY
�VAMOUNT '_
t -� PAID
PAID DATE
}
fi=..
TEMP POWER SERVICE PC
101-0000-42403
0
$16.92
$16.92
1/15/15
t BYF, +�
RECEIPT #�
#�i
CLTD BYE,
�_ F�,PAID
of 2 *METHOD
iz .Ns Y
�` i�'CHECK
JACLIN C.'SMITH
CHECK
R3425
7021
AZA
Total Paid for ELECTRICAL: $41.09 $41.09
a DESCRIPTION
.+ a `;. ACCOUNTS { ..t €
AMOUNT a » L
PAID , s f .
PAID:,DATE°
t e
.. •
'`QN?
>
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$73.98
$73.98
1/15/15
PAID.BY k "
a METHOD
r *
k f
' CHECK # ,
t
CLTD BY "
z ,
3
<3
^RECEIPT#, :n:
JACLIN C. SMITH
CHECK
R3425
7021
AZA
3, DESCRIPTION ;
<- ` ACCOUNT s
t*AMOUNT
PAID '° _
+PAIDDATE
w z is 5
,
.:QTY
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0 $30.48
$30.48
1/15/15
xPAID'BY + ' '�
�a » ` ;Vw
n
METHOD K"1�� ;,RECEIPT
#
' CHECK #
"CLTD BY
r'x'g
JACLIN-C. SMITH
CHECK
R3425
7021
AZA
b x
`V DESCRIRTION
�t
ACCOUNT }:
£aQN
YAMOUNTS
a° PAID ' i s
PAID OATEV,
E sa'
1 4a:`
es :
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$145.01
1/15/15
'PAID BY ¢ t A
METHOD
' w RECEIPT # ` ;
CHECK #
€CLTD BY
;X Y%`., ,;.'. E�.: r. D i:;::'..:•. . d ..,F �?' .
>- :..*,.: ... k ,. :.'h .. 6..ck
:ii.5' P fi}.=51'�.',.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
bESC.RIPTION a`
'`QTY
a AMOUNT
6 PAID°-
PAID -DATE:
4 }
s
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$47.86
i
1/15/15
"c ` PAID: BY
CHECK #
CLTDBMETHOD, Yf' k
z
•g
JACLIN C. SMITH
CHECK
R3425
7021
AZA
-Total Paid for ELECTRICAL - NEW CONSTRUCTION: $297.35 $297.35
[.
DESCRIPTION
r
ACCOUNT' , e
QTY�AMUUNT
`-
s: PAID '
PAIDDATE
7
��
RESIDENTIAL FINISH GRADING PC
101-0000-42600
0
$143.00
$143.00
1/15/15
:.� METHOD p' x
fb,' RECEIPT # .--
CHECK # '
CLTD BYt
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total Paid forGRADING: $143.00 $143.00
DESCRIPTIONul.
) ACCOUNTS
QTY
AMOUNT
{' PAID,, t r
PAID DATE
CONDENSER/COMPRESSOR
101-0000-42402
0
$181.30
$181.30
1/15/15
u t PAID.BYz
< METHODS
RECEIPT #
CHECK # `
CLTD BY
,;
r g
JACLIN C. SMITH
CHECK
R3425
7021
AZA
.DESCRIPTION
` x ,ACCOUNT
QTY
AMOUNT �
.x PAID
PAID DATE'
„ w
v
#
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$120.85
$120.85
1/15/15
" k PAID: BY ; f
r� =METHOD ''�
$.`RECEIPT #
` ` CHECK # u ''
CLTD By
s u:'
*`t
ti s
�i,a
JACLIN C. SMITH
CHECK
R3425
7021
AZA
t.
z 'DESCRIPTIONCCOUNTS QTY AMOUNT PAID `PAIDDATE
_w -
EXHAUST HOOD
101-0000-42402
0
$24.18
$24.18
1/15/15
n #PAID:BY s Y
METHOD ,
;RECEIPT:# r
CHECK #
CLTD BY,',,:'
_-.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
y `FL DESCRIPTIONYACCOUNT
E,
QTY
AMOUN T
PAID
PAID DATE.
'
.. ., ..
o
r
v.. .. -.:x.
EXHAUST HOOD PC ,
101-0000-42600
0
$9.66
$9.66
1/15/15
:ry PAID BY
METHOD t�'
s RECEIPT # `
#
CLTD BY
T e -
n s
,CHECK
JACLIN C. SMITH
CHECK
R3425
7021
AZA
r ,'DES'CRIPTION
ACCOUNT
QTY
AMOUNT
PAID
,_
�PAIDDATE
FURNACE
101-0006-42402
0
$181.30
$181.30
1/15/15
METHOD
RECEIPT #
CHECK #
CLTD BY
h
4
JACLIN C. SMITH
CHECK
R3425
7021
AZA
X DESCRIPTION
ACCOUNT `
QTYr
AMOUNT
PAID
PAIDDATE
FURNACE PC
101-0000-42600
0
$120.85
$120.85
1/15/15
PAID' BY
' METHOD `
wrRECE1PT #
CHECK #
C LTD BY '
x';'
,
JACLIN C. SMITH
CHECK
R3425
7021
AZA
E ;DESCRIPTION a
:'-A000,UNT
QTY
z��AMOUNT .�:
°PAID =,
PAID DATE;
VENT FAN
101-0000-42402
0
$72.54
$72.54
1/15/15
E PAID BY _
METHOD ::.
u� RECEIPT #'.
CHECK #
CLTD BY
„ -. . .: w.
...
3
,
JACLIN C. SMITH
CHECK
R3425
7021
AZA'
,': �_ DESCRIPTION
ACCOUNT Fy
QTY
AMOUNT
j; PAID
PAID, DATE
.: ...,
VENT FAN PC
101-0000-42600
0
$28.98
$28.98
1/15/15
'E' PAIOyBY' pe
METHOD"
` RECEIPT. #
CHECK'
CLTDBY
I
JACLIN C. SMITH
CHECK
R3425
7021
AZA
jt
Total Paid forMECHANICAL: $739.66 $739.66
DESCRIPTION
z ACCOUNTS
QTY
a; AMOUNT-.
! PAID '
PAID DATE-
y
MULTI -SPECIES RESIDENTIAL 0-8 UNITS
101-0000-20310
0
$1,292.00
$1,292.00
1/15/15
$Y h
MMETHOD
CHECK #
CLTD BY `.
k .RECEIPT.#'
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total
Paid for MULTI -SPECIES RESIDENTIAL $1,292.00 $1,292.00
DESCRIPTION `< r =
ACCOUNT „6
AMOUNT,
PAID
PAID DATE
;°CITY
w
NEW CONSTRUCTION PERMIT
101-0600-42400
0
$667.25
$667.25
1/15/15
PAID.BY r '� :; ?
°METHOD §
RECEIPT #
CHECK #
CLiD BY
1E :' +f
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total Paid for NEW CONSTRUCTION PERMIT: $667.25 $667.25
.DESCRIPTION
ACCOUNT
AMOUNT , :
PAID
PAID PATE
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$1,428.60
$1,428.60
1/15/15
' Al BY
METHOD
RECEIPT>#
CHECK
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTION,
' : ACCOUNT
QTY
AMOUNT
PAID
PAID DATE'
,.,,.
„.k...,
NEW CONSTRUCTION PLAN CHECK
I 101-0000-42600
0
$1,400.00
$1,400.00
10/22/14
x = PAID ,BY
w_
` METHOD
RECEIPT:#
CHECK #
CLTD.BY, `
`v
ALBERS CONSTRUCTION CO INC CHECK R2311 3839 SKH
FDESCRIPTION
=
QTY
AMOUNT €�
PAID`
S PAID'DATE
... `
Y'ACCOUNT.
r`
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$28.60
$28.60
1/15/15 .
`�e, PPAID BY
METHODw
.RECEIPT#A x
1 CHECK #kCLTD
BY
,
JACLIN C. SMITH
CHECK
R3425
- 7021
AZA
Total Paid for NEW CONSTRUCTION PLAN CHECK: $2,857.20 $2,857.20
°#DESCRIPTION �a
A000UIVT3t° R
``QTY
AMOUNT =
f PAID
PAID: DATE;
,
. ,
BACKFLOW DEVICE
101-0000-42401
0
$12.09
$12.09
1/15/15
PAID BY x '�<.;
F'�_�"•,
METHOD
�eRECEIPT
F
_`�-<.r�
JACLIN C. SMITH
CHECK
R3425
7021
AZA'
t ' DESCRIPTION > 3 'ACCOUNT
;QTY�AMOUNT
'kv
PAID
AID DATE
-
. ¢ ..,.
$�
BACKFLOW DEVICE PC
101-0000-42600
0
$4.83
$4.83
1/15/15
#'
r
z z3 PAID BY '� 4�,
METHOD
* RECEIPT:# x•
"' CHECK
CLTD BYx
�.
.'Miff?!
JACLIN C. SMITH
CHECK
R3425
7021
AZA
' °DESCRIPTION ��
ACCOUNT
T
AMOUN''
XPAID
PAID DATE
¢„ram
a,
4
BUILDING SEWER
101-0000-42401
0
$12.09
$12.09
1/15/15
k "
k"..
t,.m PAID BY ;
r' :METHOD
RECEIPTz# �s
2 14
CHECK#
CLTD BY
..• '(i'= [ ^4 4
Y..:''Y x ..: ..°"'
K xFa.%,
:&i N yt3�
JACLIN C. SMITH
CHECK ``
R3425
7011
AZA
r;
,* DESCRIPTION
ACCOUNT
CITY
AMOUNT
-
PAID' ATE.,
Y�
,nPAIUE
BUILDING SEWER PC
101-0000-42600
0
$12.09
$12.09
1/15/15
1�
PAID BY �� �
;�>�' METHOD'
r g
w $
:RECEIPT #•.
CHECK #
CLTD BY ;
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Ez 4 DESCRIPTION y
E
QTYw
N'AINIOUNT
€� PAID ,
PAID DATE,
g .;g p`
€ .A000UNTs
a.
F
FIXTURE/TRAP
101-0000-42401
0
$278.07
$278.07
1/15/15
t 'PAID BYE
METHOD n $" ° `
r t
RECEIPT
`
CHECK #z`#
CLTD BY
.,1_.&�i
e
f s
_
JACLIN C. SMITH
CHECK
R3425
7021
AZA
.DESCRIPTION:{ $'� 4,"
ACCOUNT ` &
,QTY.,
AMOUNT :>F
PAID
tPAID DATE'
€°:"
..
FIXTURE/TRAP PC
101-0000-42600
0
$278.07
$278.07
1/15/15
� 4
PAID BYE
METHOD
RECEIPT
CHECK #
BY
_.
-'Y e " ^" ik -.. � "zi i
a
.:'rc ,. •f"•r . :.....i_ . � .4As.-fu -q..
,
IrP, �p
�� P:;
,CLTD
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTION ,'�§
ACCOUNTS
QTY''
AMOUNT f
PAID ti
E' PAID DATE:
_
GAS SYSTEM, S+ OUTLETS
101-0000-42401
0
$36.26
$36.26
1/15/15
QMETHOD
"r fRECEIP7ACHECK#
CLTOBYe.
e a. .:.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTION
ACCOUNT, ' °
QTYk
, AMOUNT py
PAID g
PAID;DATE
.. ?
.
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$24.17
$24.17
1/15/15
ca METHOD;RECEIPT.#
` i'
$ CHECK # *
CLTD BY
x'L ,_,
t�
, ,:.,.• �.
,.+.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTION!i`, , str
e
ACCOUNTS ?
QTY;
`:���
AMOUNT
PAID
PAID DATE
�r jibF rr
k
..`
WATER HEATER/VENT
101-0000-42401
0
$36.27,
$36.27
1/15/15
PAID'BY ET.
METHOD';RECEIPHECK#
CLTD BYE:
zx
JACLIN C. SMITH
CHECK
113425
7021
AZA
• � . 1
7 Ate. DESCRIPTION :
ACCOUNQ
(p AMOUNT a "
gPAID ;xt�,
$PAItD A E
r�
a r
�`
ry . .,
WATER HEATER/VENT PC
101-0600-42600
0
$21.75
$21.75
1/15/15
PAID�BY'� s
s `METH(
RECEIPT
.
; CLTD BY _.
:+•
Y,
,CHEC
JACLIN C. SMITH
CHECK
R3425
7021
AZA
DESCRIPTIONav`;€�
ACCOUNT 4zt1CZTY'}>F
,AV OUNT;P
PAID s
PAID<DATE.
r
t ..�.w
WATER SYSTEM INST/ALT/REP
�101-0000-42401
0
$12.09
$12.09
1/15/15
BY
METFIOD7 ° �Is
� RECEIPT,#r
s CHECK #x
CLTD BY
„fA aPAID r
4
4
> E
JACLIN C. SMITH
CHECK
R3425
7021
AZA
G DESCRIPTIO
CfTY
€* PAID.
� �rACCOUNT�=�
r 4AMOUNT`f
_ k.
LPAIDyDATE
WATER SYSTEM INST/ALT/REP PC-
101-0000-42600
0
$12.09
$12.09
1/15/15
PAIDBY
METH.OD �3s
RECEI
CHECKy#�f+
CLTD BY j
_�.
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total Paid forFLUMBING FEES $739 87 $739.87
a
DESCRIPTION-.,.
�' ' `r
n,�:a
<QTY�
,.'x AMOUNT e i
X' PAID
PAID DATE;
..: :::"?
AACCOUNT
:... _ _.:.
.,. r. ..
SMI - RESIDENTIAL
101-0000-20308
0
$45.87
$45.87
1/15/15
METHOD `, �,%
RECEIPT:#p*
CHECK # 's 4
CLTD BY,
`4
ry, ;*
JACLIN C. SMITH
CHECK
R3425
7021
AZA
Total Paid forSTRONG MOTION INSTRUMENTATION SMt $45.87 $45.87
DESCRIPTION;
AMOUNT
PAID
PAID`DATE
z,µACCOUNT�
V'4TY
*
SINGLE FAMILY DETACHED
224-0000-20320
0
$1,837.44
$1,837.44
1/15/15
PAID By;s
METHOD r 'a
RECEIPTt#+>
CHECK #
CLTD BYE
.
_t " r.> a4'•':
,"
JACLIN C. SMITH
CHECK
R3425 •
7021
AZA
Total Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44
TOTALS:•0 $15,951.90
i
. • ess Summary,,
.83
s
%jApplie( to Approvetl,,,,
CHRONOLOGYTYPE<. t ACTION;DATE. =Y COMPLETION DATESm,
NOTES �'
tt �STAFF_NAME P. r
PLAN CHECK COMMENTS
.FROM CONSULTANT
' µ� KAY HENSELM -
11j14/2014
11/14/2014
_ STRUC RFC 11/13/14
RECEIVED
-
PLAN CHECK COMMENTS
'FROM CONSULTANT
KAY HENSEL .
. - 1/12/2015
1/12/2015
STRUC APP 1/12/2015 _
RECEIVED
i
PLAN CHECK PICKED UP
PHILIP JUAREZ
11/14/2014•
11/14/2014
MR. ALBERS PICKED UP.
PLAN CHECK SUBMITTAL
STEPHANIE KHATAMI
12/29/2014
12/25/2014
RECEIVED
CALLED ALBERS CONSTRUCTION CO. INC. @ 760-774-8787, TO
TELEPHONE CALL
JIM JOHNSON
11/14/2014
11/14/2014
INFORM THEM PLANS ARE READY FOR CORRECTIONS
1$T.PLAN CHECK. -
l '
Printed: Wednesday, January 21, 2015 4:31:14 PM 1 of 6
SYSTEMS
CALLED ALBERS CONST. @760-774-8787 PLANS READY TO
ISSUE. ITEMS NEEDED P.M. 10, SCHOOL FEES, GRAND DEED,
TELEPHONE CALL
JIM JOHNSON
1/13/2015.
1/13/2015
HOA LETTER,GRADING PLAN NOT SIGNED, CONTRACTORS LIC.
NEED S TO BE UPDATED.
CONDITIONS
. .....
CONTACTS
T',
2 OFARESSI:
APPLICANT
ALBERS CONSTRUCTION CO INC
P 0 BOX 238
LA QUINTA
CA
92247
(760)771-9954
'CONTRACTOR
ALBERS CONSTRUCTION CO INC
P 0 BOX 238
LA QUINTA.
CA
92247
(760)771-9954
OWNER
'JACLIN C. SMITH
302 E. WEDGEWOOD
SPOKANE
WA
99208
(760)771-9954.
. . ..... ....
INFORMATION,
MDESCRIPT 4�., A t
,
ID DATE4 ECEI ECK,#+ ET
—B
ART IN PUBLIC PLACES 270-0000-43201
0
.$382.17 $382.17
1/15/15
R3425
7021
CHECK JACLIN C. SMITH
'AZA.
RESIDENTIAL
Total Paid forART IN PUBLIC PLACES - AIPP: .$382.17 $382.17
BSAS SB1473 FEE.-
7-,101-0000-20306
-0
$15.00
$15.00
1/15/15
R342.5
7021
CHECK
[TH.
JACLIN C. SMITH
AZA
Total Paid for BUILDING STANDARDS ADMINISTRATION
$15.00 $15.00
BSA:
DIF - CIVIC CENTER
252-0000-43200
0'
$942.00'
$942.00
1/15/15-
R3425
7021
CHECK
JACLIN C. SMITH
AZA
DIF - COMMUNITY
254-0000-43200
0
$129.00
$129.00
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
CENTERS
DIF - FIRE PROTECTION
257-0000-43200-
0
$433.00
$433.00
1/15/15*
R3425
7021
CHECK
JACLIN C. SMITH
AZA
DIF - LIBRARIES
253-0000-43200
0
$344.00
$344.00
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
DIF - PARK
256-0000-43200
0
$40.00
$40.00
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
MAINTENANCE
DIF - PARKS/REC
--7255-0000-43200
251-0000-43200
0
$2,048.00
$2,048.00
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
DIF - STREET
F
MAINTENANCE
0' T
$116.00
$116.00
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
Printed: Wednesday, January 21, 2015 4:31:14 PM 2 of 6
opwsysums
77 T;FM 7.
CLTW
DESCRIPTION
iA E-RE
EIP
ECK-4M
r
R. ',
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
$2,842.00
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
Total Paid forDIF -'SINGLE FAMILY DWELLING: $6,894.00 $6,894.00
TEMP POWER SERVICE
101-0000-42403
0
$24.17
$24.17
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
TEMP POWER SERVICE
101-0000-42403
0
$16.92
$16.92
1/15/15
R3425
7021
CHECK
'JACLIN C. SMITH
AZA
PC
Total Paid forELECTRICAL: $41.09 $41.09
RESIDENTIAL, EA.
101-0000-42403
0
$73.98
$73.98
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
ADDITION 1,0005F
RESIDENTIAL, EA
101-0000-42600
0.
$30.48
$30.48
1/-15/15
R3425
70 - 21
CHECK
JACLIN C. SMITH
AZA,
ADDITION 1,000SF, PC
RESIDENTIAL, FIRST,
101-0000-42403
0
$145.03
$145.03,',
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
1,0005F
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
.$47.86
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
1,000SF, PC
r
Total Paid fdrELECTRICAL - NEW CONSTRUCTION: $297.35 $297.35,
RESIDENTIAL FINISH
101-0000-42600
0
$143.06
$143.00
1/15/15
1
R3425
70211.
CHECK
JACLIN C. SMITH
AZA
GRADING PC
Total Paid forGRADING: .$143.00 $143.00
CONDENSER/COMPRES
101-0000-42402
0
$181.30'
$181.30
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
SOR
CONDENSER/COMPRES
101-0000-42660
0
$126.85
$120.85
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
SOR PC
EXHAUST HOOD
101-0000-42402
0
$24.18
$24.18
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
EXHAUST HOOD PC
101-0000-42600
0
$9.66
$9.66
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
FURNACE
101-0000-42402
0
$181.30
$181.30
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH.
AZA
FURNACE PC
101-0000-42600
0
$120.85
$120.85
1/15/15
R3425.
7021_
CHECK
JACLIN C. SMITH
AZA
VENT FAN
101-0000-42402
0
$72.54
$72.54
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
Printed: Wednesday, January 21, 2015 4:31:14 PM 3 of 6
qwyerWys..m.
cF
FA,
PAID ,'
D"
VENT FAN PC
101-0000-42600
0'
.$28.98
$28.98
1/15/15
'R3425
7021
CHECK
JACLIN C. SMITH
AZA
Total Paid for MECHANICAL: $739.66 $739.66
MULTI -SPECIES
101-0000-20310
0
$1,292.00
$1,292.00
i/i S/15
R3425
7621
CHECK
JACLIN C. SMITH
AZA
UNITS
RESIDENTIAL 0-8 1TS
Total Paid for MULTI -SPECIES RESIDENTIAL $1,292.00 $1,292.00
NEW CONSTRUCTION,
7—
101-0000-42400
F 0
$667.25 T
—
$667.25
1/15g5
R3425
7021
CHECK
JACLIN C. SMITH
AZA.
PERMIT.
Total Paid for NEW CONSTRUCTION PERMIT: $667.25 $667.25 N
NEW CONSTRUCTION
101-0000-42600
0
$1,428.60
$1,428.60
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
PLAN CHECK
ALBERS
NEW CONSTRUCTION
101-0000-42600
$1,400.00
$1,400.00
10/22/14
R2311
3839
CHECK
CONSTRUCTION CO
SKH
PLAN CHECK
.0
INC
N EW CONSTRUCTION
101-00 00-42600
-0
$28.60
$28.60
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
PLAN CHECK
-
Total Paid forNEW CONSTRUCTION PLAN CHECK: $2,857.20, $2,857.20
BACKFLOW DEVICE
101-0000-42401
0
$12.09
$12.09
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
BACKFLOW DEVICE PC
101-0000-42600
0.
$4.83
$4.83
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
BUILDING SEWER
101-0000-42401
0
$12.09
$12.09
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
BUILDING SEWER PC
101-0000-42600
0
$12.09
$12.09
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
FIXTURE/TRAP
101-0000-42401
0
$278.07
$278.07
1/15/15
R3425
7021.
CHECK
JACLIN C. SMITH
AZA
FIXTURE/TRAP PC
101-0000-42600
0
$278.07
$278.07
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
GAS SYSTEM, S+
101-0000-42401
0
$36.26
$36.26
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
OUTLETS
GAS SYSTEM, S+
101-0000-42600
0.
$24.17
$24.17
1/15/15
R3425-
7021
CHECK
JACLIN C. SMITH
AZA'
OUTLETS PC.
WATER HEATER/VENT
161-0000-42401
0
$36.27
$36..27
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
Printed: Wednesday, January 21, 2015 4:31:14 PM 4 of 6
CRWYSTEMS
BY
WATER HEATER/VENT'
WATER SYSTEM
WATER SYSTEM
AZA
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $45.87 $4547
S
- _T_0�
I
1/15/15
R3425
7021
CHECK
JACLIN C. SMITH
AZA
ACHE
DET D
PARENT PROJECTS.
,s
7.
777
REMARKS
NO
N ON -STRUCTURAL
JIM JOHNSON
10/22/2014
11/13/201 . 4
REVISIONS REQUIRED
CORRECTIONS
1ST. PLAN CHECK CORRECTION REQUIRED
STRUC TO YOUNG DUE
STRUC TO YOUNG DUE 11/13
Plans ready for corrections
..11/13
STRUCTURAL
JIM JOHNSON
12/29/2014
1/12/2015
1/13/2015
APPROVED
APPROVED
PLANS APPROVED
ARMEN
ALTOUNIAN
Printed: ' 5of6
- _ CNew`nrew
1ST PW GREEN
SHEET
AMY YU
1/15/2015
1/22/2015
1/20/2015
REVISIONS REQUIRED
EMAILED BILL ALBERS AND ESSI THE COMMENTS
ON THE PRECISE GRADING PLAN
PRECISE GRADING MYLAR RECEIVED ON
1/20/2015. GREEN SHEET APPROVED WITH THE
2ND PW GREEN
AMY YU
1/20/2015
1/28/2015
1/21/2015
APPROVED-
CONDITION THAT PAD ELEVATION CERTIFICATE
SHEET
CONDITIONS
AND COMPACTION REPORT ARE REQUIRED PRIOR
TO ANY BUILDING INSPECTIONS
BOND INFORMATION
Attachment T' a CREATED OWNER DESCRIPTION PATHNAIVIE SUBDIR ETRAKIT ENABLED "
DOC
10/30/2014
JIM JOH14SON
80-871 VISTA%LAZO.docx
80-871 VISTA LAZO.docx
0 .
'DOC
12/29/2014
STEPHANIE KHATAMI
DEBRIS MANAGEMENT -
DEBRIS MANAGEMENT -
0
VISTA LAZO.pdf
VISTA LAZO.pdf
DOC
1/15/2015
STEPHANIE KHATAMI
HOA APPROVAL 80871
HOA APPROVAL 80871
0
VISTA LAZO.pdf
VISTA LAZO.pdf
DOC
1/15/2015
STEPHANIE KHATAMI
SCHOOL FEES 80871
SCHOOL FEES 80871
0
VISTA LAZO.pdf
VISTA LAZO.pdf
DOC
1/15/2015
STEPHANIE KHATAMI
ALBERS CONSTRUCTION
ALBERS CONSTRUCTION
0
INSURANCE.pdf
INSURANCE.pdf
DOC
1/15/2015
STEPHANIE KHATAMI
ALBERS SCAQMD
ALBERS SCAQMDCERTIFICATE.pdf
0
CERTIFICATE.pdf
DOC
1/15/2015
STEPHANIE KHATAMI
GRANT DEED 80871
GRANT DEED 80871
0
VISTA LAZO.pdf
VISTA LAZO.pdf
Printed: Wednesday, January 21, 2015 4:31:14 PM 6 of 6
SYSTEMS
871
Building eo_ �,v, V /C
Address �'1 / TA
Owner
Address
_Ak&LI N C .SWL IT M
zip.
143
PO. BOX 1504 APPLICATION ONLY
78-495 CALLE TAMPICO
I_A Z0 LA QUINTA, CALIFORNIA 92253
ContractorLl�iCr�S Cb1aST'Q�c'floN Cc�.iJG,
Address
..
City Zip Tel. 7 V b .
L*_ PulNr..Ik-- q1-2-SI-5 774. .4181
State Lic Lj3 I �g2L"I 2j I' City Sq. Ft
& ClassX9 Lic. " Size
Arch., En�r.,
Designer/ STRi1�TS !"NG
S 50 SD . OILeA44 be Q-
Klwt Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm tha am licensed unde rovisions of Chapter 9 (commencing with Section 7000)
of Division oft use s a ssions Cod ,and y 'cens is 'n full jprce nd Effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county w ' quires a permit to construct,
alter, improve, demolish, or repair any structure, prior to its iss ce also requires the applicant for
such permit to file a signed statement that he is licensed p uant to the provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Sectio 000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a p mit subjects the applicant to a civil penalty of
not more than'five hundred dollars (S500).
❑ I, as owner of the proZmnyor my employ s with wages as their sole compensation, will do
the work, and the structnot intende r offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contraicense La does not apply to an owner of property who builds or
improves thereon and wes such rk himself or through his own employees, provided that
such improvements are ended r offered for sale. If, however, the building or improvement
is sold within one year ofletio the owner -builder will have the burden ofproving that he did
not build or improve for trpo of sale).❑ I, as owner of the propxclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Busid Professions Code: The Contractor's License Law does not apply
to an owner of property ilds or improves thereon, and who contracts for such projects with
a contractors) licensednt to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensa 'on Ins rance, or a F�Ified copy I preo`t. y/S.ec. 38000,, La or Code.)
Policy No. 0=' - 'C6mpany 1s1 J
Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS'COMPENSATIONINSURANCE
(This section need not be completed if the permit is for o undred dollars ($100) valuation
or less).
I certify that in the performance of the work for whI911 this permit is issued, I shall not employ
any person in any manner so as to become subject orkers' Compensation Laws of California.
Date Owner
NOTICE TO APPLICANT.' If, after makin is Certificate of Exemption you should become
subject to the Workers' Compensate provisions of the Labor Code, you must forthwith
comply with such provisions or this pe it shall be deemed revoked.
CONSTRUCTION LENDING AGENC
I hereby affirm that there is a constr/ays.
ding agency f he performance of the work for
which this permit is issued. (Sec. 3097, .)
Lender's Name
Lender's Address
This is a building permit when prod t, signed and validated, and is subject to
expiration if work thereunder is suspendays.I certify that I have read this appld state that the above information is correct.
I agree to comply with all city and cinances and state laws relating to building
construction, and hereby authorize reives of this city to enter the above -mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING: TYPE CONST. " .00C. GRP.
A.P. Number % 7r 2 d ( 0
Legal Description L.n t' 10 ' Wart- 7,034
Project Description
I L91 t7 u GvyeQ-e-b L.c5g I (A C U„d-r VW -N!� A-c.)
No No. w.
J No.
QX ( &QErUnits 1
New ❑ Add Nery Repair ❑
Demolition ❑
i-/
Estimated Valuation 1 t Moot 0&
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I. '
Grading
Driveway Enc.
t
Infrastructure
TOTAL
(�
CONTACT INFORMATION
NAME:
PHONE:
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line —
Rear Setback from Rear Prop. Line _
Side Street Setback from Center Line
Side Setback from Property Line —
FINAL DATE INSPECTOR
Issued by: —
Validated by:
Date
WHITE = BUILDING DEPARTMENT
Validation:
YELLOW = APPLICANT
PINK = FINANCE
tea. •
Coachella Valley Unified School District This Box For District Use only
83-733 Avenue 55, Thermal, ICA 92274 ' DEVELOPER FEES PAID
(760) 398-5909 — Fax, (760) 398-1224
AREA: -
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMIIND. AMOUNT:
DATE:
RECEIPT:"
CHECK #:
' INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Named JaclinSmirt�h Date: January 14, 2015
Owner's Name: Phone No. "
Project Address: 80-871 Vista Lazo, La Quinta; CA 92253
Project Description: Single Family Dwelling Unit
APN: ' 762-250-010 Tract #: Lot #'s:
Type of Development: Residential , XX Commercial Industrial
Total Square Feet of Building Area: 5;092 Sq. Ft.
Certification of Applicant/Owners:' The person signing certifies that the above iriformationis correct -and makes this statement under
penalty of pequry and further represents that he/she is authorized to sign on behalf of the owner/developer..
1 / .
Dated: 1 Signature:
SCHOOL DISTRICT'S°REQUIREMENTS FOR THE ABOVE PROJECT'HAVE BEEN OR WILL BE SATISFIED -IN
ACCORDANCE WITH ONE OF THE FOLLOWING:' (CIRCLE ONE)
Education Code Gov. Code Project: Agreement Existing .:.. Not Subject to Fee
17620 65995 ' Approval Prior to 1/1/87 Requirement
Number of Sq.Ft. .5,092 Sq. Ft.: '
Amount per Sq.Ft. $ 3.36
Amount Collected $ 17,100.12.
Building Permit Application Completed: Yes/No
By:. Elsa F. Esqueda,.Director of Facilities and Maintenance
Certificate issued by: Leticia Torres, Facilities Analyst Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF F D TAT ME OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that th't515istrict provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions("Fees"), of the 90-day period to protest the imposition of these.
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90-day protest period in regard to such Fees'or the validity thereof, commences with the payment of the fees or performance•of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in. part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions. may be granted.
iN4V:c/Inydoes/devlecs/certificate ofcompliance firm updated 3-2007 11/2010
Page 1 'of 5 Doc TTax Paid
Recorded in Official Records
+ RECORDMiti REQUESTED BY: County of Riverside
Orange Coast Title Co. Larry W. Ward 1
Assessor, County Clerk & Recorder
AND WHEN RECORDED tIAA1L TO:
isclin C. Smith .
t 1302 E. Wedgewood Ave. * —This document was electronically submitted
Spokane, WA 99208 to the County of Riverside for recording"
Receipted by: AGONZALEZ
r nro ar•AW: I -UK KtWK0tK'5 USE ONLY:
Title Order No.: 1661►7W 10 n Escrow No.: 041162-OL
GRANT DEED
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX Is $220.00
[XI computed on full value of property conveyed, or „
[ I computed on full value less value of liens or encumbrances remaining at time of sale.
I I Unincorporated area [XI City of La Quints AND
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Watson David Todd Bortftwlck and Kathryn Joyce Borthwick, Husband and Wife
hereby GRANT(s) to:
Jaelln C. Smith , a single woman '
,
the real property in the City of La Quints, County of Riverside, State of California, described as:
Lot 10 of Tract No. 28034, in the City of La Quinta, County of Riverside, State of California, according to Map
recorded in Book 258, Pages 69 and 70 of inclusive of Maps, in the Offico of the County Recorder of California.
Also Known as: Vacant Land APN 762-250-010-1, La Quints, CA 92253
AP#: 762-250-010-1
DATED April 22, 2014
STATE OF Washington ti CZL nz j
COUNTY OFOn atson David Todd Borthwick
before me, r [ C wY• V� A Notary Public personally appeared, ---
Watson David Todd Borthwick and _ thryn ce ck .. ,
Kathryn Joyce Bortmick
who proved to me on the basis of satisfactory s ev�nce to be
the person(s) whose nsme(s) Islam subscribed to the within
instrument and acknowledged to me that he/shetthey 1 .
executed the some. in hisrherAheir authorized cspactty(iea),
and that by his&wAheir signatura(s) on the instrument the
person(s), or the entity upon behalf of which the person(s)
acted, executed the instrument. „
I certify under PENALTY OF PERJURY under tha laws of the state
of Caftmis that the foregoing paragraph Is bw end corrwA. �i. r,
WITNESS my hand and ofriclal sagl. t ,
Signature "(Seal)
MAIL T STA E O PARTY HOWN BELOW; IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE:
RIVERSIDE,CA -
Document: DD 2014.170015
Branch :OCC,User :3600 Comment: ; Station Id :SOL'I
,s •
A DOC #2014-0170015 Page 3 of 5 05/09/2014 08:00 AM
ACKNOWLEDGMENT ,
STATE OF WASHINGTON
COUNTY OF WHATCOM
4 .
P. I certify that I know or have satisfactory evidence that t r t) A-
u 0 f.).rt�.u�ck et,
3 Ware the person(s) who appeared before me and that said person(s) acknowledged that
shetlWthey signed this instrument and acknowledged it to be he4ltis/their free and
voluntary act for the uses and purposes mentioned in the instrument.
Givenunder my hand and seal of office this j day of C l •iit , 2014.
Laura Lesley Vestanen, Notary Public Notary Public
Residing at Point Roberts, WA State of Washington
Commission number 95291 z LAURA LESLEY VESTANEN
' My Commission Expires: 10 August 2015 My Commission Expires
August 10, 2015
Description of attached ddocument t.
Title
t
Document date Number of pages
Comments
RIVERSIDE,CA Page 3 of 5 . ` ' 'Printed on 11/3/2014 3:57:19 PM
Document: DD 2014.170015
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 9/25/2009.
Green Sheet approvals are forwarded to the Buildina & Safety Department directiv by Public Works. Please DO
NOT submit the Green. Sheet (Public Works Clearance) Packet to the 'Public Works Department until ALL
requirements listed below are complete. Incomplete applications or applications which cannot be processed will be
returned to applicant..
Date: /�� !S Developer: Omsi-a-lo VT k013 Cy 141-C.
Tract No.: 2034 Tract Name: L1,,rvg GkT-M Lot No.(s)
10
Address(s): ytsrk LA -to Phone Number: OW ) %7 q ` k7 A%
The following are the requirements for Public Works Clearance to authorize issuance of a building permit: from the
Building & Safety Department:
❑ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW
❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW
❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 &.#7 BELOW
❑ WALLS, .SIGNS, OTHER: PROVIDE ITEM #6 BELOW
1. Attach Pad Elevation Certificates in compliance with .the approved design elevation for _ building pad
(maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6
months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet
submittal until a Pad Elevation Certificate can be provided.
2. Attach geotechnical certification of grading'plan compliance including compaction reports from a licensed
Soils Engineer. Recently rough graded residential developments which have a previously approved
geotechnical certification are exempt from this requirement.
3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots.
4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10
plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy
plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with
grading plans & are subject to additional requirements. A current PM10 certification.number is required.
5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building
location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain
development plan.
6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations.
7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW
approved building construction projects require either a WQMP or a completed WQMP exemption form.
Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx
I have reviewed and confirmed the requirements listed above as presented and find the improvements to be
sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s).
Pursuant to my findings, the above project may be released for building permit issuance.
This section completed by City staff.
Recommended by: Date:
Public Works Distribution: ( Green Sheet to Building & Safety "A/771_ Pf1'U f_E?2r 47VI,?
( ) Green Sheet to Planning Department Ga^04 70ti 1�7�.
Declined for approval for reason(s) as follow(s), please correct and resubmit:
I
TAChecklists - For s & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10-02-12.doc
City of La Quinta - PM 10 Fugitive Dust Control Project Information
Construction Phase PM 10 Agreement (< 1 acre/Int or Infill Prniectl
Project Information
Project Contractor: ALP,u_;'i . Co*)s il-u er wv-� �'� G
Project Phase
(check one)
Construction
0 Demolition
Project Name: - fAIA l m Qmyt 11 �2A_-St D L--U C .—
Project Tract/Lot Numbers: ' AZT Z�'0 3�( t Lo Tr- t 0 .
Project Street Address: 80 1,ik
LA- Du #NTk- CA- S3
Anticipated Start Date:/ / Anticipated Completion DateJfi�
:
Total Acres in Active
Construction (< 1 acre per
Lot): S 0 '� j r
PM10 Contact Information .
Please note: Dust control is required 24 hours a day, 7 days a week, regardless of
construction status. Person listed below is responsible for dust control during
business and non -business hours.
Name:
Title:
f it S% as V_ {'
Company Name:
A `\n�e_YS `C)vJS'j0-VCrLvkZJ CQ
Mailing Address:
Pip 23 8
City, State, ZIP Code:
L.d�(D v I l ZZ�I
Primary Phone #:
t kao - -r) ri Li - O
Fax #:
24 Hour Emergency
Phone#:
C G
(DU
Cell Phone #:
Email Address:
b a A IVws O
PM 10 Certificate #:
�v S—0 D 1 (O 3 I ^ I 1 11
The above stated nronerty owner (or authnri7Pd rP.nrP.SP.ntgfivP.1'
Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to
SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP;
:• Shall constitute an Agreement to comply with all project conditions as identified in the approved dust
control plan.
Acknowledges that dust control is required twenty-four. (24) hours a day, seven (7) days a week,
throughout the period of project performance, regardless of project size or status;
❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project
shall be in ,continuous compliance with all requirements of the approved dust control plan;
Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the
dust control plan are necessary-,
Shall authorize representatives of City/County to enter the property for inspection and/or abatement
purposes;
Shall hold harmless the City/County and its representatives from liability for any actions related to this dust
control plan or an City/County initiated) abatement activities.
Signature of P operty Owner or Authorized Representative Date
Y ~ 'e);,,..-'_.•'� �. `�-. ,,,`��, ^l7 :-r `C. s.�,,- ���.,' _ y[���� ,' J�`-vim �ca�t.- .{`+� • - a �,.
��. ,� �: • V �I .It.,,.�'. .%�.�'�.t �+' �t'.•1.4-y�,('C t�...,C. �"`.t ..,✓.�.^..-.'77Y[[ rf 1�
�r -;n ( �::. t'i t•� � � �ti. �{ { ��. 1 '1 Y` , � I_-�* `� l �\N. �. f�( ^,I._'•• ai` ' ��c.. � ': ,a.'� •y "• 4� ,� i.i '- ,y I �:- Y
k�� l!"�r�.. Jar �. J''+•i�-3��� '2%��.�+:'i7R� �3". `�', .�.t,{��., ;�,�j `'i �.�- � \�`f � `�'.r�i:r��J 'V.`• - r
South Coast Air Quality Management District
. t - acknomledges by thi
or
AV
Ay,. •fi ' '. .,vYmj • .. 4
�r !
• that
r Bill Albers
t
successfully completed , _
•�y 5� - C;OA-CH�ELL�1 Yiw- �Y FUCaTIVE BUST CONTI�,OL CLASS
p ? 01/15/2015 ezaAf
Date Issued:
j� (Eapirer 2yearrJrom date of irrf+ante), Training Officer
Engineering and Compliance
ru
CV1501-001632-1717
w
'; � � ���(,�t%Z~t�L�:aI"�,�,'1 �vC.ij`�,r.�,'�- `Cj� .� �F.` t T',...:1 i� 4:`�t/� �3t�'�%-'� �;6.''C�'�.�t'.�1a rf r��. 1�'<<P..'v.i �`-"�,:!r�`\��•,�`l� .�'!'r�i `„+'gin,
a�fi�'� .'r �-^-.,p-«..«-.vn^orr.�.:�.n.aw•. ,�. '[,-�;: � -. - - - -. _ -- .. -. ,.'`�dwFfaw"$..a,-�-ms4.-.--ax'.^^4�*'�ve'�.+�4^�.
Plan Submittal
Building Permit Number. .
Project Description: SFR Demo
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
12/17/2014
Job Site Address] 60871 Vista Lazo
Owner's N1
Number, Street, or PO
City. State, Postal C
Owners Phone Nun
Owners E-MaU Add
Jaclin Smith
106 Jaciln Way
Sandpoint, ID. 83864
50"94-4135
Project-Manage's Name B1II Albers
Project Managers Phone Number 760-774-8787
Project Menagers E-mail Address b.albersO.eaRhlink.net
Builder / Contm
Number, Street or PO
City, State, Postal C
Albers" Construction Co. Inc.
po� . - 4ox 238
gZ24�-
Project Square Footegel aipprox. 5,904 sq ft
City Approval.By
Date of City Approval
To Be Discardei
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated 1 Reuse•
*Describe Items
Recycle Trash
43.5 . 24.0
0'
.O
3n
3
�
_z o
m
n
T
rM C
.z
3D
rn
z
—f
ble Product
Tons
Masonry (broken)ff6.25
-PlasterScrap
MetalTile
(floor).
Tile (root) 0.75
Wood
Landscape Debris_ 0.00
Diversion:
84.44%
I understand it is the property ownses responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. t hereby certitythat completion, implementation and adherence of the
Debris Management Plan'(DMP) for the above named project shall guarantee thatat least 50% of the jobstte waste is
diverted from landfiliing. The remaining material will be recycled or mused. I will divert, for -recycling or reuse, remaining
materials generated from the first day of the project through the compledon.otthe project In accordance with this pion. This
DMP is issued in the name of the propertyowner(s) and shall remain their property throughout the construction andlor
demolition project. A contractor serving as egent.of the owner may obtain a DMP for the owner. However, the DMP Is still
'Issued in the name of the property owiier(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bbmonthly reports. If self -hauling, all refuse.material from this project site must be taken to an approved recycler or transfer .
wQ+. �� Crrid vu l(0 e. j�. Date / 231`Y
. . -
Owner / Developer I Project Manager uperinienNnt
YOUNG
r
A ENGINEERING
' . -. ram°°'� .. ' , �%` €.�
- E •
{ Letter of Transmittal
To: City of La Quinta _-.Today's Date:
1-12-15
' 78-495 Calle Tampico City Due Date:
1-12-15 .
La Quinta, CA 92253 ,, x ' Project Address: 80-871 Vista Lazo
Attn: Kay Plan Check #:
BRES 2014-1143 _
Submittal:. ❑ `ist' s
❑. '. 4th
. J E 3'd
❑ ' Other:
-We are forwarding: �® By Messenger,- ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions: " `" - r Includes:
`. ' # Of Descriptions:
r.. Copies:.Copies:
.
' '_ ❑ Structural Plans : �' • ' ?
®' 1 Revised Structural Plans .
.1 Structural Calculations , ,��•r''
❑ Revised Struct. Calcs .
Truss Calculations Floor
❑ Revised Truss
and Roof
v3
Report
® Soils _ p
❑ Revised Soils Report
Structural Comment List/
3
®
7
3' Approved Structural, Plans '
_
Responses
- ® 1'. Redlined Structural Plans
❑ ' • Approved Structural Calcs
❑ - Redlined Structural Calcs
❑ Approved Truss Calcs
❑ Redlined Truss Calcs
❑.. " Approved Soils Report
- °`❑ Redlined Soils Reports y
❑ , Mt, er•
Comments: Structural content is approvable.
If you have any questions, please call.
CITY OF _ .
Time = 2.25 HR
BlEVELOPIvii
1 This Material Sent 'for'.
❑ Your Files ,� ' ' i _
®. ` Per Your Request
❑ 'Your Review ` " ,
' ❑ Approval
❑ Checking ` �'
❑ At the request of:
r Other: ❑
.
. :By: Kathryn Samuels
,...
-Palm Desert Office: ® (760) 772-5107
' Other :.❑
,
t� +
1�
BUILDING ENERGY ANALYSIS REPORT
'
PROJECT:
- - Jaclin , C. Smith Residence ,
#
_ ;Lions Gates #10 ;
* La. Quinta, CA 92253
.Project Designer: .
Stracts Architects
.� 550 S. Oleander
Palm Springs, CA92262..
", (760) 636-8951
' CITY OF LA QUINTA
' Report. Prepared by:: BUILDING & SAFETY DEPT.
»'•
Jon Scott APPRO ED
FOR CONSTR CTION
Tll`
Scott Design and Title 24, In
.
77-085 Michigan Drive s
DATE
.. Palm Desert, CA 9221.1
(760) 200-4180
Job Number:
Date:
'
12/4/2014
•
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential'2013 Building Energy Efficiency Standards.
s� t
This program developed by EnergySoft, LLC — www.energysoft.com.
Ene Pro'6.3 by EnergySoft User Number 6712: )D:
' x
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tation
OD
Project Name: Jaclin C. Smith Residence Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith -Res -Lions Gate-STRACTS-14.xml
CFOF-01
Page 1 of 12
GENERAL INFORMATION
01
- Project Name
Jadin C. Smith Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
Lions Gates #10
04
A City
La Quinta
05
Standards Version
Compliance 2015
06
Zip code
92253
07 "
Compliance Manager Version
SEMCmpMgr 2013-3 (651) .
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.3
.10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
120
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
- Total Cond. Floor Area (FTZ)
5092
15
.8� Number of Zones
4
16
Slab Area (FTZ)
5092
Number of Stories
1
18
Addition Cond... Floor Area
N/A
0^9'�
Natural Gas Available
Yes
20
Addition Slab Area (FTZ)
N/A
a�2�1
Glazing Percentage (%)
18.8%
COMPLIANCE RESULTS
'
01
Building Complies with Computer Performance Aft.�
02
This building incorporates features that require field testing am verification by a certified HERS rater under the supervision of a CEC-approved HERS provided
03
This building incorporates one or more Special Features shop"tbelow
ENERGY USE SUMMARY
04
05�.
06
07
08
-�'Energy r Use
(kTDV�/ft)C)
Standand
6Design
Proposed
Design
Compliance
Margin.
Percent
Improvement
l m Space Heatin
4.84
4.83
0.01
0.2%
.' !k a6e Cooling .
�10P 126.12
124.99
1.1-3
0.9%
I IAQ� V,entila`tio`n� I
�1.30
1.30
0.00
0.0%
I Wier. eavhg�
5.04
5.62
-0.58
-11.5%
PhoroGoJta1,c` ffs
—
0.00
0.00
—
�mplia-ReEner y T6tl o
et.A
137.30
136.74
0.56
0.4%
z®�
Registration N Registration Date/Time:
CA Building Energy Efficiency Stand5r'ds - 2013 Residential Compliance Report Version - CF1R-16172014-651
HERS Provider:
Report Generated at: 2014-12-04 14:45:23
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE.� OD .
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04; 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
REQUIRED SPECIAL FEATURES
The following are.features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Window overhangs and/or fins
CFF-01'
Page 2 of 12
HERS FEATURE SUMMARY
The following is a summary of the features that'must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:.
• IAQ mechanical ventilation
Cooling System Verifications:
• Verified EER
.
Verified SEER
• Refrigerant Charge
V.
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications.
°®
• -Duct Sealing
Domestic Hot Water System Verifications:
— None —
,.
ENERGY DESIGN RATING 4L%�. -
This is the sum of the annual TDV energy consumption for energy use components includ5, in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy UW
Energy Desrgn Ratrng 'd
Margin .
Percent Improvement
Total Energy. (kTDV/f2p
174.32 �N�
y ' ` 173 76
0.56
0.3%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
A
BUILDING ! FEATURES INFORM71TiOfl
�01 T
02 t�
0
04
05
06
07
0;01
Pr j pt Named L
;Coed tioned Floor Area (Oft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Jaclin C. rMh Resi en&eJ
-' l 5092 VJ
1
12
4
.4
2
Liciency
m nomRegistration N.Registration Date/Time:
CA Building Entandards 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-12-04 14:45:23
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF19RF-01
Page 3 of 12
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftZ)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Bedroom
Conditioned
HVAC 1 masterl
871
14
DHW Sys 1
Kitchen Dining
Conditioned
HVAC 2 kit2
864
14
DHW Sys 1
Greatroom & Hall
Conditioned
HVAC 3 & 4 great3
2245
14
DHW Sys 1
Bedroom 2,3 & 4
Conditioned
HVAC 5 bed4
1112
14
DHW Sys 1
OPAQUE SURFACES -
01
02
03
�� 04
05
06
07
08
Name
Zone
Construction �
Azimuth
.Orientation
Gross Area (ftZ)
Window Area (ft)
Tilt deg)
30d Wall
Master Bedroom
R-21 Wall (W21.2x6.1,6)j�
30
Right
378
40
90
120d Wall
Master Bedroom
R-21 Wall (W.21.24 16),Y
120
Front
378
0
90
210d Wall
Master Bedroom
R-21 Wall (W.21..2z6.16)
210
Left
1210
57.9
90
300d Wall
Master Bedroom
R-21 Wall (W.2i':Fx6A6)
300
Back
672
46
90
Roof
Master Bedroom
R-38 R of Attic
871
30d Wall 2
Kitchen Dining
R-21 Walh(W21.2x6.16)
30
Right
462
102.4
90
300d Wall 2
Kitchen Dining
R-21gWall (W.21.24.16)
300
Back
462
76
90
Roof 2
Kitchen Dining
SR-38 Roof Attic
A.
864
30d Wall 3
Greatroom. & Hall
- 21 Wall (W21.24.16)
30
Right
210
13
90
E Wall
Greatroom & Hall
®`FR-21 Wall (W21.2x6.16)
90
specify -
210
13
90
120d Wall 2
Greatroom & Hall
R-21 Wall (W.21.24.16)
120
Front
1650
183
90
Nall UJ
Greatroom & Half"
R-21 Wall (W.21.2x6.16)
180
specify -
378
0
90
10d�Nall 2
rn
Greatroom & Hall �
R-21 Wall (W21.2x6.16)
210
Left
210
25 .
90
W Wall O C_
Greatroom & Hale
R-21 Wall (W21.2x6.16)
270
- specify -
210
18 .
90
3 0 Wall 3
® 1 Greatroom & Hall)'
R-21 Wall (W.21.24.16)
300
Back
924
222
.90
oof3
Greatroom.&KHall
Va..
R-38 Roof Attic
2245
3 d all 4 (n
Bedroogi!G�3 & 4
R-21 Wall (W21.24.16)
30
Right
1386
66
90
12 d k3pil 3 :13
Beds 0 2,3 & 4
R-21 Wall (W.21.24.16)
120
Front
525
45.9
90
210 Wall 3
Bloom 2,3 & 4
R-21 Wall (W.21.2x6.16)
210
Left
627
50
90
no Wall 4
Bedroom 2,3 & 4
R-21 Wall (W.21.24.16)
300
Back
672
0
90
R o 4
(fl Bedroom 2,3 & 4
R-38 Roof Attic
1112
v®�
Registration Nurrijbe :
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-10172014-651
HERS.Provider:
Report Generated at: 2014-12-04 14:45:23
CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE, COMPLIANCE OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14,42, Thu, Dec 04,2014
Calculation Description: Title 24 Analysis . Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF F-01
Page 4of12
ATTIC
01
02
03
04
05
06
07
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons
3
0.1
0.85
No
No
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF•RF-01
Page 5 of 12
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
NEW
Window
30d Wall (Right-30)
-
-
1
40.0
0.28
0.28
Insect Screen (default)
NEW 2
Window
210d Wall (Left-210)
-
-
1
4.0
0.28
0.28
Insect Screen (default)
NEW 3
Window
210d Wall (Left-210)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 4
Window
210d Wall (Left-210)
-
-
1
3.9
0.28
0.28
Insect Screen (default)
NEW 5
Window
210d Wall (Left-210)
- <
A -
1
6.0
0.28
0.28
Insect Screen (default)
NEW 6
Window
210d Wall (Left-210)
-
-
1
7.5
0.28
0.28
Insect Screen (default)
NEW 7
Window
210d Wall (Left-210)
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 8
Window
210d Wall (Left-210)
o r
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 9
Window
210d Wall (Left-210)®�-
--
1
6.0
0.28
0.28
Insect Screen (default)
NEW 10
Window
210d Wall (Left-210)
"�' -
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 11
Window
300d Wall (Back-300) `�
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 12
Window
300d Wall (Back-300) ®`
-
-
1
40.0
0.28
0.28
Insect Screen (default)
NEW 13
Window
30d Wall 2 (Right-30)
-
-
1
102.4
0.28
0.28
Insect Screen (default)
NEW 14
Window
300d Wall 2 (Back-300) s��
--
--
1
76.0
0.28
0.28
Insect Screen (default)
NEW 15
Window
30d Wall 3 (Right-30)
-
--
1
13.0
0.28
0.28
Insect Screen (default)
NEW 16
Window
E Wall (- specify-90)•y'
-
-
1
13.0
0.28
0.28
Insect Screen (default)
NEW 17
Window
120d Wall 2 (FronYl�120)
-
-
1
11.0
0.28
0.28
Insect Screen (default)
NEW 18
Window
120d Wall 2 (R6nnt=120)
-
-
1
11.0
0.28
0.28
Insect Screen (default)
NEW 19 _
�Wirado
120d Wall 2k( ront-120)
-
-
1
11.0
0.28
0.28
Insect Screen (default)
NEW 20
Window0J
120d Wal�lr2:(Front-120)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 21
ER
11AIrLdow r
120d(Wall 2 (Front-120)
-
--
1
25.0
0.28
0.28
Insect Screen (default)
NEW 22
Q nd6w
120iiyWall 2 (Front-120)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 23 W cow
n.
12ed Wall 2 (Front-120)
-
-
1
13.0
0.28
0.28
Insect Screen (default)
NEW 24 V�nd# go
W20d Wall 2 (Front-120)
--
-
1
13.0
0.28
0.28
Insect Screen (default)
NEW 25 V�(OJ°'' U)
��V 120d Wall 2 (Front-120)
-
-
1
13.0
0.28
0.28
Insect Screen (default)
NEW 26 ::r
120d Wall 2 (Front-120)
-
-
1
13.0
0.28
0.28
Insect Screen (default)
NEW 27 Wi - ow
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 28 VV
120d Wall 2 (Front-120)
--
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 29 Win • w
120d Wall 2 (Front-120)
-
-
1
6.0 1
0.28
0.28
Insect Screen (default)
74
Registration Number: I •��r Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:45:23
CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF*F-01
Page 6of12
NEW 30
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 31
Window
120d Wall 2 (Front-120)
--
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 32
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 33
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 34
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28.
0.28
Insect Screen (default)
NEW 35
Window
210d Wall 2 (Left-210)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 36
Window
210d Wall 2 (Left-210)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 37 _
Window
W Wall (- specify -270)
-
-
1
18.0
0.28
0.28
Insect Screen (default)
NEW 38
Window
.300d Wall 3 (Back-300)
24.0
# 8.0
1
192.0
0.28
0.28
Insect Screen (default)
NEW 39
Window.
300d Wall 3 (Back-300)
-+�'
-
1
30.0
0.28
0.28
Insect Screen (default)
NEW 40
Window
30d Wall 4 (Right-30)
1
6.0
0.28
0.28
Insect Screen (default)
NEW 41
Window
30d Wall 4 (Right-30)
-
1
30.0
0.28
0.28
Insect Screen (default)
NEW 42 -
Window
30d Wall 4 (Right-30)
-
-
1
.6.0.
0.28
0.28
Insect Screen (default)
NEW 43
Window
30d Wall 4 (Right-30) ��
d -
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 44
Window
30d Wall 4 (Right-30) �
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 45
Window
30d Wall 4 (Right-30) ®�
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 46
Window
30d Wall 4 (Right-30) ``
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 47
Window
120d Wall 3 (Front-120) •®�
-
-
1
3.9
0.28
0.28
Insect Screen (default)
NEW 48
Window
120d Wall 3 (Front-120)0
-
-
1
42.0
0.28.
0.28
Insect Screen (default)
NEW 49
Window
210d Wall 3 (Left-21�0).#
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 50
Window
210d Wall 3 (Leftj2j1;0)
-
-
1
25.0
0.28
0.28
Insect Screen (default)
NEW 51
Window
210d Wall 3 (�♦j?210)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
s� i A11%
DOORS t7 ` /
-i 041� � --`
�' " 02
03
04
I Na ie�� �
Side of Building
Area (ft)
U-factor
Do�0
S Wall
20.1
0.50
OVERHANGS AND fl �S Cif (n ��
01 03
T1 0 •t
03
04
05
06
07
08
09
10
11
12
13
1 14
x.✓� `� Overhang
Left Fin
Right Fin
Left
Right
Windo
e61
Dist Up
Extent
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
NEW 3
r4
0.1
18
18
0
0
0
0
0
0
0
0
0
Registration Number: I Registration Date/Time:
CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-12-0414:45:23
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CFF OR
Page 7of12
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
2x4 Top Chord of
Cavity/Frame: no insul. /2x4 Top Chrd
Roof Truss @ 24 in.
Roof Deck: Wood Siding/sheathing/decking '
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
• Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 16 in: O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O., GG?�
R 21
Exterior Finish: Wood Siding/sheathing/decking
hk�
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone,
Area (ft2) �
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Covered Slab
Master Bedroom
871-*v
109
None
0.8
No
Covered Slab 2
Kitchen Dining
8"
44
None,
0.8
No
Covered Slab 3
Greatroom & Hall
e�&.245
170
None
0.8
No
Covered Slab 4
Bedroom 2,3 & 4
�•�'1112
151
None
0.8
No
BUILDING ENVELOPE.- HERS VERIFICATION
t�m01 -
02
03
04
Quality I`n'sulation Installatiort ydilI
Quality Installlaiion of Spray Foam Insulation
Building. Envelope Air Leakage .
ACH @ 50 Pa
m Not Required I-
7 r,
v Not Required
Not Required
a tl -n � s 1 17 .
WATER HEATING SYSTEM!r) ' -5
V `
'. .
-7
A.
1 7 - 90 '
02 A
03
04
05 06
N
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW y 1 7�
D�
Pipe Insulation, All Lines
DHW Heater 1
1
.0%
DHW ty 1 C . rT
i
[)�IMI
Pipe Insulation, All Lines
DHW Heater 1
2
.0%
z®��®
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651
HERS Provider:
Report Generated at: 2014-12-04 14:45:23
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF*F-01
Page 8of12
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01"
02
03
b,04 "
05
06
07
Name
Pipe Insulation
Parallel Piping
"
Compact Distribution
Point -of Use
Recirculation"
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
v N/A
N/A
N/A
N/A
N/A
N/A
DHW Sys.1 - 1/2
N/A
N/A
s N/A -
N/A
N/A
N/A
HVAC SYSTEMS 4w '
01
02
03 �..
04
05
06
07
Heating Systgii
Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC 1 masterl
Other Heat/Cool
Heating Component 1
Yes
Cooling Component,1
Yes
Air Distribution
System T'
871
HVAC 2 kit2
Other Heat/Cool.
ftz
Heating Component 2
Yes
Cooling Component 2
:Yes
Air Distribution
864
System 2
HVAC 3 & 4 great3
tier eat/Cool '
Heati gq Component 3..
�K
Yes
Cooling Component 3
Yes
Air Distribution '
System 3
2245
HVAC 3 & 4, re43
COther. Heat/Cool
v
Hteating Component 3
Yes
Cooling Component 3
Yes
Air Distribution
System 3
2245 `
w
I
HVAC 5 b d4
� ther H
Heating Component 4
Yes
Cooling Component 4
Yes
Air Distribution
1112
�q at/Cool
System 4
I O u 90
-- �
) )
c:: <rn-
-� rn
o® �
z �
Registration Number: ���O Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-12-04 14:45:23
CERTIF,JOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF*F-01.
Page 9 of 12
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntriFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntdFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS.
01
02
03
04
05
06
07
Efficiency 00
Multi -speed
Name
System Type
EER
Zonally Controlled
Compressor
HERS Verification
�4SEER
Cooling Component 1
SplitAirCond - Split air conditioning
13
��e
16
No
No
Cooling Component
system
��
1-hers-cool
Cooling Component 2
SplitAirCond - Split air conditioning
13
> 16
No
No
Cooling Component
system
2-hers-cool
Cooling Component 3
SplitAirCond - Split air conditioning
13 p
16
No
No -
Cooling Component
system
3-hers-cool
Cooling Component 4
SplitAirCond - Split air conditioning
, �®
T13 ®
16
F
No
No
Cooling Component
system
-
I
4-hers-cool
1_
HVAC COOLING - HERS VERIFICATION
01
02 �a
03
04
05
06
a
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Comp n¢rtt 1-hers71q of
= Required ��`
350
Required
Required
Required
Cooling Comp n nt-2-her o, C
= Required
350
Required
Required
Required
Cooling Comp n t 3-herCpo NO
1;,,) Required
350
Required
Required
Required
Cooling Comp e t 4 hers= o
go t I Required'
350
Required
Required
Required
Registration Number: ��
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - U1R-10172014-651
HERS Provider:
Report Generated at: 2014-12-0414:45:23
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time:.14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF*F-01
Page 10 of 12
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System .1
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution
;
System 1-hers-list
Air Distribution System 2
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution
System 2-hers-list
Air Distribution System 3
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution
System 3-hers-dist
�
_
Air Distribution
Air Distribution System 4
Ducts located •in attic
Sealed and tested
-8
Attic .
��
Attic
None
System, 4-hers-dist
HVAC DISTRIBUTION- HERS VERIFICATION ®®`�
01
02
03`
04
05
06
07
Duct Leakage
r
Verified Duct Design
Low -leakage
•
��
Name -
Verification
Duct Leakage Target (0
Verified Duct Location
Return Supply
Air Handler
Air Distribution System
Required
q
6.0
Not Required
Not Required
Not Required
—
1-hers-dist
Air Distribution System
Required'
66-0
Not Required
Not Required
Not Required
—
2-hers-dist
^
Air Distribution System.
3-hers-dist
Required
6.0
Not Required `
Not Required
Not Required
—
A'1D,
Air Distribution System
Required
�`a
6.0
Not Required
Not Required_
Not Required
—
4-hers-dist
�®
I n w.r I ► ALr -
HVAC. FANJ SfFSTEMST
~ C7
02
03
04
N �Ie U
Type
Fan Power (Watts/CFM)
HERS Verification
��
I HVAC{Ean t
&A W Single Speed PSC Furnace Fan
0.58
HVAC fan 1-hers-fan
HVAC_jjF�n (J3
�a Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
WHVAC
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC s
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4-hers-fan
=ml!llftl
HVAC FAN SY EIMS - H R iC T'10 --*
01
02
03
s
Registration Numu'.� Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-0414:45:23
CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04,.2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.icml
CF F-01
Page 11 of 12
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58 .
IAQ (Indoor Air Quality) FANS
01
02
03
04
06
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
DwellingUnit
148.42
0.26
Default
0
Required
COOLING VENTILATION
01
02
03
04
Name
Cooling Vent CFM
Cooling Vent Watts/CFM
Number of Fans
WH Fan 1
61 v
0.52459
1
WH Fan 2
61
0.52459
1
WH Fan 3
61 ���
0:52459
1
WH Fan 4
61 `®�
0.52459.
1
40>
rn
-Lr,-
CA--
°®®
Registrati-
on Date/Time:Registration Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651.
HERS Provider: -
Report Generated at: 2014-12-0414:45:23
CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml .
CF, F-01
Page 12'of 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I. certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signatur
Jon d. SCott
Jon Scott
Company:
Signature Date: -
Scott Design and Title 24, Inc,
12/4/2014
Address:
CE:A/HERS Certification Identification (If applicable):
77-085 Michigan Drive
City/Stat ip:
"Falm Desert,' CA 92211'
Phone:
(460) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT'
I certify the following under penalty of perjury, under the laws of the State of California: o��
1. 1 am eligible under Division 3'of the Business and Professions Code to accept responsibility forithe building design identified on this Certificate of Compliance.
2., 1 certify that the energy features.and performance specifications identified on this Certificate 'Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
.or
3. The building design features system design features identifed on this Certificate of.Comp ance are consistent vvith'the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agencyWor approval with this building permit application.
Responsible Designer Name: �.
Responsible Designer Signature:
Stracts Architects •A�
`
Company: v
Date Signed:
Stracts Architects �1
Address: ��
License:,
550 S. Oleander®®.
City/State/Zip: r� --
Phone:
Palm Sp7ings, CA 9276 '7 ,�� .
.(760) 636-8951
90,
QM
o®o
Registration Numb Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:
Report Generated at: 2014-12-04 14:45:23
•
E
•
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Jaclin C. Smith Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
121412014
Project Address
Lions Gates #10 . La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area'
5,092
Addition
n/a
# of Units
1 .
INSULATION
Construction Type
Area
Cavity ft) Special Features Status
Roof Wood Framed Attic
R 38 5,092
New
Wall Wood Framed
R 21 9,586
New
Slab Unheated Slab -on -Grade
- no insulation 5,092 Perim = 474'
New
Demising Wood Framed
R 13 2,479
New
Door Opaque Door
no insulation 20
New
FENESTRATION
Orientation Area ft2
I Total Area: 958 Glazing Percentage: 18.8 %
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor: 0.28
Exterior Shades Status
Right (NE) 221.4
0.280
0.28 none none
Bug Screen New
Left (S1M 132.9
0.280
0.28 none none
Bug Screen New
Rear (NKq 152.0
0.280
0.28 none none
Bug Screen New
Front (E) 13.0
0180
0.28 none none
Bug Screen New
Front (SE) 228.9
0.280
0.28 none none
Bug Screen New
Rear (1/10 18.0
0.280
0.28 none none
Bug Screen New
Rear (NVI9 192.0
0.280
0.28 18.0 none
Bug Screen New
HVAC SYSTEMS
Qty.. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
2 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R-Value Status
HVAC 1 master Ducted
HVAC 2 kit Ducted
Ducted Attic
Ducted Attic.1Ty
C).
w
HVAC 3 & 4 great Ducted
Ducted Attic
Q1 JILDINGO& S
ew
WATER HEATING
Qty. Type
APPRoVED
Gallons Min. Eff Distributio CONSTRU(*-Quh
2 Small Storage Gas
50
0.66 All Pipes Ins
New
BY
EnemvPro 6.3 by EnemySoft User Number 6712
Run Code: 2014-12-04T14:46:01
ID:
Page 15 of 39
•
•
•
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Jaclin C. Smith Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
121412014
Project Address
Lions Gates #10 La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,092
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity ftz Special Features Status
FENESTRATION
Orientation Area ft2
Total Area: ng Percentage: 18•8 % New/Altered Average U-Factor: 0.28
U-Fac SHGC' Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
HVAC 5 bed Ducted
Ducted AtticC)I/veWTA
o ^
T.
�V
WATER HEATING
Qty. Type
°°
Gallons Min. Eff, Distribution FOR CONSTRU�1,aOtus
0
DATE _-- --
EnemvPro 6.3 by EnemySoft User Number: 6712 Runcode: 2014-12-04T14.46:01 ID:
Page 16 of 39
4
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R
Project Name
Date
Jaclin C. Smith Residence
121412014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
110.6 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form.
§110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the
installation of a Cool Roof is specified on the CF-1 R Form.
" 150.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U-factor.
150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
* 150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U-factor.
* 150.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U-factor.
150.0 : Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form.
150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U-factor of 0.58.
2. The weighted average U-factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)l: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
reater, is exempt from the maximum U-factor requirement.
150.0 r Solar Ready Buildings. Shall meet the requirements of Section .110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150.0 h : Heating and/or cooling loads are calculated in accordance with ASHRAE SMAGNA-e
150.0 i : Heating systems are equipped with thermostats that meet the setback re u
en(eis�SON TAcQU 1 V TA
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than tie
wrapped with insulation havinq an installed thermal resistance of R-12 or greater.
_ _ r-
§150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating s7 ter4-, Q h in`dir._ . hot wat
r
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation Rlvel ire ivii�iq�cUhTJor of t
tank.
DATE BY -
EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 17 of 39
110.4 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cov
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a t
programmed to run only during off-peak electric demand periods.
150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, pipin
Residential Lighting Measures:
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for co
with TABLE 150.0-A or TABLE 150.0-B as applicable.
§150.0(k)1 C: The wattage of permanently installed luminaires shall be determined as so
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name Date
Jaclin C. Smith Residence 1121412014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.0Q)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards
Table 120.3-A.
150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal openings greater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
§150.0(m)7: Exhaust fan systems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
§150.0(m)10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include
all: the following components:
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A gas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating or a pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heatinn.
r.
met SNuitft1� dll9llaSWAVE1716et
filters, w I � n 50.0 .
FOR CONSTRUCTION
pliance with Section 150.0(k) in accordancE
AWS
§150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic an5 shall ave an output frequency — 20 kHz
§150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not
be required to be controlled by vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page 18 of 39
4
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
Jaclin C. Smith Residence
121412014
150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150.0 k .
150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts
for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a, manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; .
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eigkt+eFFRGF-ve4qjeles-peFsall
complV with the applicable requirements in Sections 110.9 130.0 130.2 130.4, 140.7 and 141 0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not conta
ocke rra�y u
a screw-b WWI ��P
no more than five watts of power as determined accordingto 1 30.0d .
BUILD�I�I� & S�i-t�
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply the
/s
PROVED.
with applicable requirements for nonresidential garages in Sections 11
.9, 13 0 30
130.4, 140.6, and 141.0.
FOR CONSTRUCTION
§150.0(k)12A. Ina low-rise multi -family residential building where the total interior common areLin single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that builshall be high efficacy luminaires or
controlled by an occupant sensor. TE BY
§150.0(k)12B. In a low-rise multi -family residential building where the total interior common are
20 percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and a ress.
EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page 19 of 39
4
4
.HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
actin C. Smith Residence
Date
12/4/2014
System Name
HVAC 1 master
Floor Area
871
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total ROOM Loads 803
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation ` 203
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
110,000
14,186
1,710
209
17,120
Total Output Btuh
110,000
0
Output Btuh/s ft
126.3.
819
841
Cooling System
0
0
Output perSystem
37,000
8,945
4,626
203
9,807
Total Output Btuh
37,000
0
.819
1 24,769 6,336
0
Total Output(Tons),3•1
841
Total Output Btuh/s ft
42.5
Total Output s ft/Ton
282.5
28,609
Air S stem
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Carrier 24AN13136-58CVX110
31,783
0
110.000
Airflow cfm/s ft
1.38
Airflow cfm/Ton
389.2
Outside Air %
16•9 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
31,783
0
110.000
Outside Air cfm/s ft .
0.23
Note: values above given at AR! conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
203 cfm
71 OF
64 OF 150 °F� 150 OF -
Heating Coil Supply Fan a
1,200 cfm 149 F
�.� ROOM
72 OF
ri
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Co ling Peak
112/78OF
Outside Air
203 cfm
71 /59°F
LEnerg
78/63°F 53/52°F 53/52.OF CI1 i OF
PI 1 DING SAFETY DEPT.
c
Cooling Coil Supply Fan FOR CONSTRUCT�O 53 / 52 °
1,200 cfm — -- -
52.0 %
DATE--
70/59°F
Pro 6.3 b Energ Soft
User Number: 6712 Run Code: 2014-12-04T14.46:01 /D: Page 20 of 39
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Wan C. Smith Residence
Date
12/4/2014
System Name
HVAC 2 kit
Floor Area
864
ENGINEERING CHECKS
SYSTEM LOAD.
Number of.S stems
1
COIL
CFM
Total Room Loads 841
Return Vented Lighting
Return Air Ducts
Return fan
Ventilation. 202
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
110,000
14,848
1,696
119
9,802
Total Output Stuh
110,000
0
Output Btuh/s ft
127.3
857
482
Cooling System
0
0
Output perSystem
37,000
8,867
4,597
202
9,788
Total Output Btuh
37,000
0
6,293
0
Total Output(Tons)
3•1
857
482
Total Output Btuh/s ft
42.8
Total Output s ft/Ton
280.2
25,430
20,554
Air System
CFM perSystem
1,200
. HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Carrier 24ANB136-58CVX110
31,767
0
110,000
Airflow cfm/s ft
1.39
Airflow cfm/Ton
389.2
110,000
Outside Air °i°
16.8 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
31,767
0
Outside Air cfm/s ft
0.23
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
202 cfm
72 OF
64 OF 150 OF 150 OF
Heating Coil Supply Fan °
1,200 cfm 150 F
ROOM
72 OF
rn
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak)
112/78OF .
Outside Air
202 cfm
71 /59OF
78/63°F 53/52°F 53/52OF' CI t i OF °—' °
T SAFETY DEPT.
R�
Cooling Coil Supply Fan FOR CONSTj�UCTIO 3 / 52 OF
1,200 cfm---
52.0 % �Q
DATE
70/59°F
En&g Pro 6.3 by Energ Soft
User Number: 6712 Run Code: 2014-12-04T14:46:01 /D: Page 21 of 39
4
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Jaclin C. Smith Residence
12/4/2014
System Name
Floor Area
HVAC 3 & 4 great
2,245
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 3,637
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 524
Supply Fan'
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating S stem
Sensible
Latent
CFM
Sensible
Output per System
110,000
32,866
4,408
674
32,254
Total Output Btuh
220,000
0
Output Btuh/s ft
98.0
1,897
1,585
Cooling System
0
0
Output per System
52,300
23,165
4,133
524
25,436
Total Output Btuh
104,600
0
1,897
1. 59,826 8,541
0
Total Output Tons
8.7
1.585
Total Output Btuh/s ft
46.6
Total Output s ft/Ton
257.6
60,861
Air System
CFM per System
?,000
HVAC EQUIPMENT SELECTION
Airflow cfm
4,000
Carrier 24ANB160-58CVX110-24ANB148
63,103
31,377
220,000
Airflow cfm/s ft
1.78
Airflow cfm/Ton
458.9
220,000
Jan 1 AM
Outside Air °i°
13.1 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
63,103
31,377
Outside Air cfm/s ft '
0.23
Note: values above given at ARI conditions
Aug 3M
HEATING SYSTEM PSYCH ROM ETRICS
Airstream Temperatures at Time of Heating Peak).
26 OF
66 OF 117 OF 117 OF
Outside Air
524 cfm
Heating Coil Supply Fan
4,000 cfm 117 OF
ROOM Sim
72 OF
72 OF
CITY ®F FADUI
„ ,. DEPT.
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Coolin 'eak R--
A
112178 OF
76 / 66 OF 61 60 OF 61 / 60 OF
FOR CONSTRUCTION
Outside AirA.
c BY
524 cfm
Supply Fan DATE _------
Cooling Coil 62 / 60 OF
4,000 cfm --
71.4 % ROOM
70/64°F
70/64°F
EnergyPro 6.3 by Energ Soft
User Number: 6712 RunCode: 2014-12-04T14:46:01 ID: Page 22 of 39
L-
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
actin C. Smith Residence
Date
12/4/2014
System Name
HVAC 5 bed
Floor Area
1,112
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,488
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 259
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
110,000
16,964
2,183
452
21,541
Total Out ut Btuh
110,000
0
Output Btuh/s ft
98.9
979
1,059
Cooling System
0
0
Output perSystem
55,600
11,470
3,220
259
12,565
Total Output Btuh
55,600
0
979
1 30,393 5,403
0
Total Output Tons
4.6
1,059
Total Output Btuh/s ft
50.0
Total Output s ft/Ton
240.0
36223
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ANB160-58CVX110
36,223
13,035
110,000
Airflow cfm/s ft
1.80
Airflow cfm/Ton
431.7
Outside Air %
13.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
36,223
13,035
110,000
Outside. Air cfm/s ft
0.23
Note: values above given at ARI conditions
Aug 3 PM
Jan .1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
259 cfm
72 OF
66 OF 117 OF 117 OF
i
Heating Coil Suppiy.Fan
117 OF
2,000 cfm
ROOM rU
72 OF
CITY aOF LA Q AntSAFETY DEPT.
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at.Time of Cooling Pel1i ` —, -. rr- a e-v® Bif
112/78OF
Outside Air
259 cfm
70/62 OF
76/65°F 59/58°F 59/58°F
}0:"
c
Cooling Coil Supply Fan
2,000 cfm-
I-CO�� �.-
FOR CONSTRUCTIO N
- �� BY
59 / 58 OF
65.5 % I ROOM =o
70 / 62 OF
Energ Pro 6.3 by Energ Soft
User Number: 6712 RunCode: 2014-12-04T14.46:01
ID: Page 23 of 39
a
ROOM LOAD SUMMARY
Project Name
Jaclin C. Smith Residence
Date
121412014
System Name
HVAC 1 master
Floor Area
871
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name
Room Name
Mult.
CFM
Sensible
Latent
CFM
Sensible
Latent
CFM
Sensible
Master Bedroom
Master Bedroom
1
803
14,186
1,710
863
14,186
1,710
209
17,120
NITA
ncoT
3UILERINIG
FOR
C
ATE
BY
PAGE TOTAL
803
14,186
1,710
209
17,120
11
ROOM LOAD SUMMARY.
Project Name Date
Jaclin C. Smith Residence 121412014
System Name Floor Area
HVAC 2 kit 864 .
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Kitchen Dining Kitchen Dining - 1 841 14,848 1,696 841 14,848 1,696 119 9,802
LJI I Y lJ LJ-'► v i v a �-.
BUILDING & SAF
P
FOR C NSTR JCTION
PAGE TOTAL
TOTAL*
' Total includes ventilation load for zonal systems.
EnergyPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-12-04T14:46:0
841
14,848
1,696
. 119
9, 802
841
14, 848
1, 696
119
9, 802
1LJ
•
ROOM LOAD SUMMARY
Project Name Date
Jaclin C. Smith Residence 121412014
System Name Floor Area
HVAC 3 & 4 great 2,245
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible' Latent CFM Sensible
Greatroom & Hall Greatroom & Hall 1 3,637 32,866 4,408 3,637 32,866 4,408 674 32,254
EMME
li�®
TOTALM1 W. NEWS I
TOTAL Total includes ventilation loa.
wip
�•
3,637
01�-
32,866
4,408
6741
3Z254.
3,637
32,866
4,408
674
32,254
26 of 39
•
•
•
ROOM HEATING .PEAK LOADS
Project Name
Jaclin C. Smith Residence
Dat e
121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Bedroom
Floor Area 871.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 T
Conduction
Area
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
—
=
=
=
=
=
=
=
=
=
-
=
=
_
=
=
_
=
_
=
=
=
=
_
_
-
=
-
=
_
=
46
Btu/hr
R-38Roof Aftic
871.0
X'.
0.0260
46
1,042
R-21 Wall (W.21.2x6.16)
2,494.1
X
0.0690
46
7,916
Low-E Vinyl
143.9
X
0.2800
46
1,853
Slab -On -Grade
penim = 109.0
X
X
X
X
X
X
0.7300
46
3,660
"R-13 Wall
613.0
0.1020
0
0
.
X
-
X
X
X
X
X
X,
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to
X 871 X
Area Ceiling
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
another room .
14.00 X 0.266
Height ACM
Page Total
/ 60 ] X
AT
14,472
= 2,648
TOTAL HOURLY HEAT LOSS FOR ROOM 17,120
EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-12-04T14:46:01 /D: Page 28 of 39
C ]
C
ROOM HEATING PEAK LOADS
Project Name
Jaclin C. Smith Residence
Date
121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Kitchen Dining
Floor Area 864.0 ft2
Indoor Dry Bulb Temperature .. 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U-Value
864.0 X 0.0260
745.6 X 0.0690
178.4 X 0.2800
perim = 44.0 X 0.7300
411.0 X 0.1020
X
X
x
x
X
X"
X
X
X
x
X
x
X
X
X
X
X
X
X
X
X
X
X
x
x
x
through an interior surface to another room
X 864 X 14:00 X 0.266
Area Ceiling Height _ ACH
X
X
X
X
X
X
X
x
x
X
X
X
X.
X
x
x
x
X
x.
X
X
X
X
X
X
X
x
x
X
x
AT °F
Btu/hr
R-38Roof Attic
46
=
=
_
1,033
R-21 Wall (W.21.2x6.16)
46
2,367
Low-E.Vinyl
46
2,298
Slab -On -Grade
46
=
c
1,478
'R-13 Wall
0
0
c
_
_
-
=
=
=
_
=
=
=
_
=
_
=
_
=
=
=
-
_
_
p OE
l
6
-
FEN
D
UCTION
FOR G
=
Page Total
DATE
/ 60 X 46
AT
Items shown with an asterisk. denote denote conduction
Infiltration:[ 1.00 X. 1.b64
Schedule Air Sensible
Fraction
By 7 17
TOTAL HOURLY HEAT LOSS FOR ROOM 9,802
EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-12-04T14.46:01 ID: Page 29 of 39
•
ROOM HEATING PEAK LOADS
Project Name
Jaclin C. Smith Residence
Date
121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Greatroom & Hall
Floor Area 2,2415.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
..X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT'F
Btu/hr
R-38 Roof Attic
2,245.0
0.0260
46
c
2,685
R-21 Wall (W.21.2x6.16)
3,297.9
0.0690
46
=
10,468
Low-E Vinyl
474.0
0.2800
46
=
6,105
Wood Door
20.1
0.5000
46
=
462
Slab -On -Grade
pen .m = 170.0
0.7300
46
=
=
5,709
'R-13 Wall
714.0
-0.1020
0
0
=
=
_
=
=
-
=
-
=
=
=
=
-
_
-
=
=
=
-
=
-
-
=
Items shown with an asterisk.(') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 2,245 X
Area
another-roomF
14.00 X
Height
�g�,TO I
®INV
ra
5, 29
so
6 _ -6, 5
1CONSTRUCTION
TOTAL HOURLY HEAT LOSS FOR ROOM 32,244,
DATE BY
EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-12-04T14:46:01 Page 30 of 39
•
•
ROOM HEATING PEAK LOADS
Project Name
Jaclin C. Smith Residence . 777.
Date
121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2,3 & 4
Floor Area 1,112.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X.
to
Ceiling
U-Value.
X
. X
X
X
X
X
X
X
X
X
X
X
X
X
X
X.
X
X
X
X
X
x
X
X
X
X
X.
X
X
S
AT °F
=
=
=
=
=
=
=
=
_
=
_
=
-
=
-
_
_
_
_
_
=
=
=
=
_
_
_
-
_
(_�
reVY
4(
Btu/hr
R-38 Roof Attic q
1,112.0
0.0260
46
1,330
R-21 Wall (W..21.2x6.16)
3,048.1
0.0690
46
9,675
Low-E Vinyl
161.9
0.2800
46
2,085
Slab -On -Grade
perim = 151.0
0.7300
46
5,071
`R-13 Wall
741.0
0.1020
0
0
_
TA
rter
Items Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
through an interior surface
X 1,112 X
Area
another roo;CH
14.00
Height
SP-a9z
FQp;�C+Q
ATFraction
E _� 6Y
_ 18, , 0
3,38 .
-
TOTAL HOURLY HEAT LOSS FOR ROOM 21,541
EnergyPro 6.3 by EnergySoft User Number. 6712 Run Code: 2014-12-04T14.46:01 /D: Page 31 of 39
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
• Jaclin C. Smith Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Master Bedroom Outdoor Dry Bulb Temperature
Floor Area 871.0 ft2 Outdoor Wet Bulb Temperature
Indoor Dry Bulb Tem erature 70 OF Outdoor Daily Ranqe:
C � J
Oaaoue Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
"R-13 Wall
Orientation
Area
X
X
X
X
` X
X
X
X
X
U-Factor
X
X
X
X.
X
x
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
871.0
0.026.0
56.0
338.0
0.0690
27.0
378.0
0.0690
31.7
1,152.1
0.0690
29.3
626.0
0.0690
31.2
613.0
0.1020
0.0
Page Total
Items shown with an asterisk"(') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)'
Fenestration
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
Gain
Orientation
(NE)
(SW)
(SIM
(SIM
(SK9
(sK9
(SIM
(SW)
(SWJ
121412014
112 OF
78 OF
34 OF
Btu/hr
1.268
1
1 6,4011
Shaded
Area
Unshaded
GLF . Area
X 16.0 + 40.0
X 16.0 + 4.0
X 16.0 + 6.0
X 16.0 + 3.9
X 16.0 + 6.0
"X 16.0+ 7.5X
X 16.0 + 12.5
X 16.0 + 6.0
X 16:0 + 6.0
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
-
Btu/l
0.0
22.0
0.0
20.3
0.0
20.3
0.0
20.3
0.0
20.3
0.0
20.3=
0.0
20.3
0.0
20.3
0.0
1 20.3
Page Total
1
2.6 Occupants X 245 Btuh/occ.
871 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.94 X 55.88 X 42 =
Air Sensible CFM ELA AT
860
81
122
79
122
152
254
122
Btu/hr
640
1,486
2,336
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM t41.
Latent Gain C
2.s BUILDING & SAFETYB@WrT
Occupants
Occupants X 15 oa�c.Btuh/®�2RI� D 405
0 x x F//'STON
"Infiltration: 4,771 X 0.94 55.88 0.00523 = FOR CONR 1,305
Air. Sensible CFM ELA AW .
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
BY
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jaclin C. Smith Residence
12/4/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name MasterBedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area 871.0 ft2
Outdoor Wet Bulb Temperature
78.OF
Indoor Dry Bulb Temperature 70 OF
1 Outdoor Daily Range:
34 °F
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
X
X =
X
X
X
X =
X
X =
X
X -
X.
X
X
X =
X
X =
X
X _
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1,. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btu/hr
NEW (SK9 0.0 X 16.0 +
6.0 X 20.3 =
122
NEW (NW) 0.0. X 16.0 +
6.0 X 27.5 =
165
NEW (NW) 0.0 X 16.0 +
40.0, ,X 27.5 =
1,101
X +
X _
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
1,388
Internal Gain
Btu/hr
Occupants 2•6 Occupants X,1 245
Btuh/occ. =
640
Equipment 871 Floor Area X 0.50
w/sgft =
1,486
Infiltration: 1.064 X 0.94 X 55.88 X 42 =
2,336
Air Sensible CFM ELA. AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
A UUIM,
s
& SAFEV D
Latent Gain
BUILDING
r
Occupants 26 Occupants X 15
Btuh/o(!01..a�)�
e" 405
FOR CONSTR
4 771
Infiltration: X 0.9.4 X 55.88 X 0.00523 =
1;305
Air Sensible CFM ELA pW
BY
DATE ----�
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
405
EnemyPro 6.3 by EnemySoft User Number: 6712 Run Code: 201412-04T14:46:01 ID:
Pa a 33 of 39
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jaclin C. Smith Residence
12/4/20.14
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Kitchen Dining
outdoor Dry Bulb Temperature
112 OF
Floor Area 864:0 ft-'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor CLTD'
Btu/hr
R-38 Roof Attic' (W) 864.0 X,
0.0260 X 77.0 =
1,730
R-21 Wall (W.21.2x6.16) (NE) 359.6 X
0.0690 X 33.0 =
819
R-21 Wall (Vt!21.2x6.16) (Nim 386.0 X
0.0690 X 50.4 =
1,342
"R-13 Wall 411.0 X
0.1020 X 0.0 =
0
x
X —
X
X =
X
X -
X
X =
X
X =
Page Total
3,890
Items shown with an asterisk (") denote conduction through,an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD) ,
Shaded
.Unshaded
Fenestration Orientation Area GLF • .
Area GLF
Btu/hr
NEW (NE) 0.0 X 19.5
+ 102.4 X 26.4 =
2,701
NEW (NW) 0.0 X 19.5
+ 76.0 X 50.4 =
3,830
X
+ X. _
X
+ X =
X
+ X =
.X
+ X
X
+:. X
X
+ .. X =
X
+ x =
Page Total
6,531
Internal Gain
Btu/hr
Occupants 2 6 Occupants X
245 Btuh/occ. =
635
Equipment 864 Floor Area . X
0.50 w/sgft _
1,474
Infiltration: 1.064 X 0.94 X 55.43 X , • . 42
Air Sensible . CFM EIA, AT
F 1 A u
O L
ll 1�
TOTAL HOURLY SENSIBLE HEAT GAIN' FOR ROOM
14,848
AHVhUvr
Latent Gain
CONSTRUCT(IRWhr
FOR
Occupants 2 6. Occupants X r
1 5 Btuh/occ. =
402
Infiltration: 4,771 X 0.94 X. 55.43 X 0.00523 =
DATE BY,
Air Sensible CFM'' ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM.
402
EnemyPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-12-04T14,46:01
ID: Page 34 of 39
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name 7121412014
ate
• Jaclin C. Smith Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name GreStroom & Hall Outdoor Dry Bulb Temperature 112 °F
Floor Area 2,245.0 ft' Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF
r�
LJ
Ooaaue Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
Wood Door
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
Orientation
(NE)
(E)
(SE)
(S)
(S)
(SW)
(1/109
(NW)
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
0
=
.2,245.0
0.0260
56.0
197.0
0.0690
27.0
197.6
0.0690
33.0
1,467.0
0.0690
31.7
357.9
0.0690
26.0
20.1
0.5000
26.0
185.0
0.0690
29.3
192.0
0.0690
33.0
702.0
1 0.06901
31.2
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
Oriont2finn
(NE)
(E)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
Page Total
Shaded Unshaded
Area
X
X
X
X
X
X
X.
X
X
GLF
Area
+ 13.0
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
0
-
0.0
16.0
22.0
0.0
16.0
+
'13.0
32.6
0.0
.16.0
+
+
11.0
23.1
0.0
16.0
11.0
23.1
0.0
16.0
+
11.0
23.1
0.0
16.6
+
+
12.5
23.1
0.0
16.0
25.0
23.1
0.0
16.0
+
12.5
23A
0.01
1 16.0
+
13.01
1 23. 1
Page Total
Internal Gain
Occupants LE
Occupants X 245 Btuh/occ.E ui ment Floor Area X 0.50 w/sgft =
Infiltration: 1:064 X 0.94 X 144.04 X 42 =
Air Sensible CFM EI.A AT rCITY OF LA
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
Occupants 6 7 Occupants X 155
Infiltration: 4,771 X. 0.94 X 144.04 X 0.00523 =
Air Sensible CFM- ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Code:
Btu/hr
642
261
374
437
1, 509
10,5141
Btu/hr
286
424
255
255
255
289
579
289
301
1,650
3, 831
..
866
C Li
FOR CONSTRUUMN
uh/occ. = 1,044
DATE B
1, 444
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Jaclin C. Smith Residence 12/4/2014
ROOM INFORMATION DESIGN CONDITIONS
Room Name Greatroom & Hall Outdoor Dry Bulb Temperature 112 OF
Floor Area 2,245.0 ft' Outdoor Wet Bulb Temperature 78 OF.
Lin dor D Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF
Opaque Surfaces
'R-13 Wall
Area U-Factor CLTD'
714.0 X 0.1020 X 0.0 =
X X =
X X =
X X =
X X =
X. X =
X X =
X X =
X J X I=
Page Total
Items shown with an asterisk (') denote conduction through an.interior surface to another room
1. Cooling Load Temperature Difference (CLTD)
I FanPgtrntinn
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
I Internal Gain
rientation
Ariantatinn
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
Shaded . Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
Area
+ 13.0
+ 13.0
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
-
0.0
16.0
23.1
0.0
16.0
23.1
0.0
16.0
+
13.0
23.1
0.0
16.0
+
+
6.0
23.1
0.0
16.0
6.0
23.1
0.0
16.0
+
+
6.0
23.1
0.0
16,0
6.0
23.1
0.0
16.0
+
+
6.0.X
23.1
0.0
16.0
1 6.01
23.1
6.7 Occupants X 245 Btuh/occ.
2,245 Floor Area X 0.50 w/sgft
Page Total
Btu/hr
Btu/hr
301
301
301.
139
139
1.39
139
139
1,
Btu/hr
1,650
3,831
Infiltration: 1.064
Air Sensible
X 0.94
CFM
X 144.04
ELA
X 42 = 6,021
AT
TOTAL HOURLY SENSIBLE HEAT GAIN.FOR'ROOM
3 ass
BUILDIN(a
Latent Gain PPROVE
Occupants 6 7 Occupants X 15 �,h(of�(vSTRUC�
Infiltration: 4,771 X 0.94 X 144.04 X 0.005.3 =
Air Sensible CFM ELA AW DATE BY
Btu/
Oi TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Jaclin C. Smith Residence
121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Greatroom & Hall
Outdoor Dry Bulb Temperature
112 °F
Floor Area 2,245.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor CLTD'
Btulhr
X
X =
X
X =
X
X -
X
X =
X
X -
X
X =
X
X _
X
X =
X
X =
Page Total
o
Items shown with an asterisk (') denote conduction though an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF .
Btulhr
NEW (SE) 0.0 X 16.0
+ 6.0 x 23.1 =
139
NEW (SE)'. 0.0 X 16:0
+ 6.0 X 23.1 =
139
NEW (SIM 0.0 X 16.0
+ 12.5 X 20.3 =
254
NEW (SIM 0.0 X 16.0.
+ 12.5 X 20.3 =
254
NEW (W) 0.0 X 16.0
+ 18.0 X 32.6 =
587
NEW (NW) : 112.8 X 16.0
+ 79.2 X 27.5 =
3,984
NEW (NW) 0.0 X 16.0
+ 30.0 X 27.5 =
626
X
+ X =
X
+ X =
-
Page Total
6, 983
Internal Gain
Btulhr
Occupants fi 7 Occupants X
245 Btuh/occ. =
1,650
Equipment 2,245 Floor Area X
0.50 W/s ft =
q
3,831
Infiltration: 1.064 X 0.94 X 144.04 X 42 =
02
Air Sensible CFM ELA• AT
CITY ®�
III -DING &SAFETY DEPT.
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
32,86
Latent Gain
FOR CONSTRUCTIOBN
thr
Occupants 6 7 -Occupants X]
155 Btuh/occ. =
1,044
Infiltration: 4,771 X 0.94 X 144.04 x 0.00523 _
DATE BY--_-
---
3,364
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,044
Ene Pro 6.3 by Ene Soft User Number: 6712 RunCode: 2014-12-04T14:46:01
ID: Page 37 & 39
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name e
Dat
Jaclin C. Smith Residence 121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room. Name Bedro0'M 2,3 & 4
Floor Area 1,112.0'ft2
Indoor Dry Bulb Temperature 70 OF
Outdoor Dry Bulb Temperature 112 °F
Outdoor Wet Bulb Temperature 78 OF
.Outdoor Daily Range: 34 OF
Op ague Surfaces
Orientation
(W)
Area
1,112.0 , X
1,320.0 X
479.1 X
577.0 X
- 672.0 X
741.0 X
X"
X
X
U-Factor
CLTD'
X 56.0 =
X 27.0 =
X 31.7 =
X 29.3 =
'X 31.2 =
X 0.0 =
X =
X =
X =
Btulhr
R-38 Roof Attic.
0.0260
1,619
R-21 Wall (W.21:2x6.16)
(NE)
0.0696
2,459
R-21 Wall (W21.2x6.16)
(SE)
0.0690
1,047
R-21 Wall (W.21.2x6.16)
(svio
0.0690
1,168
R-21 Wall (W.21.2x6.16)
(NW)
0.0696
1,445
"R-13 Wall
0.1020
0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
Area
X
X
X
X
X
X
X
X
X
GLF
I
+
+
+
+
+
+
+
+
+
.Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.01
16.0
6.0
22.0
0.0
16.0
30.0
22.0
0.0
16.0
6.0
22.0
0.0
16.0
6.0
22.0
0.0
16.0
6.0
22.0
0.0
16.0
6.0
22.0
0.0
16.0
6.0
22.0
0.0
16.0
3.9
23.1
0.0
16.0
42.0
23.1
Page Total
Internal Gain
Occupants 3.3 Occupants X 245 Btuh/occ: _
Equipment 1,112 Floor Area X 0.50 -w/sgft =
Infiltration: 1.064 X . 0.94 X 71.35 X 42
Air Sensible CFM ELA AT
CfF-T�7qF LA QUIN
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13 U I LU I.IN U
Latent Gain AP
R CONSTRUCTION
Occu ants 3 3 Occupants X . 155 Btuh/occ. _
Infiltration: 4,771 X 0.94 X 71.35 X. 0.00523 = DATE BY
Air Sensible CFM ELA pW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
7. 737I
Btu/hr
132
660
132
132
132
132
132
90
972
Btulhr
817
1,898
--"2.982
to/hr
•
E
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project, Name
Date
Jaclin C. Smith Residence
7121412014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2,3 & 4
Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,112.0 ft2
Outdoor Wet Bulb
Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range: 34 OF
Opaque Surfaces Orientation ` Area U-Factor CLTD' Btulhr
X
X =
X
X =
X
X -
X
X =
X
X =
X.
X =
X
X =
X
X =
X
X =
Page Total 0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF Btu/hr
NEW (SK9 6.0 X 16.0
+ 12.5 X 20.3 = 254
NEW (SK9 0.0 X 16.0.
+ 25.0 X 20.3 = 508
NEW (SK9 0.0 X 16.0
+ 12.5 . X 20.3 = 254
X
+ X
X
+ X =
X
+ . X =
X
+ X _
X
+ X _
X
x =
Page Total 1,01
Internal Gain
Btu/hr
Occupants 33 OccupantsX
245 Btuh/occ. = 817
Equipment 1,112 Floor Area X
0.50 w/sgft = 1,898
Infiltration: 1.064 X 0.94 X 71.35 X 42 _
Air Sensible
/ 9
C' 1 I OF.
CFM ELA AT
FBUILDING & SAFETY DEPT.
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,96
FOR CONSTRUCTION
Latent Gain
Btu/hr
Occupants 3 3 Occupants X
4155 Btuh/occ. = 51
TEInfiltration:
4,771 X 0.94 X 71.35 X=
1,666
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
517
EnemvPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-12-04T14:46:01
ID: Page 39 6! 39
CEFe.rIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
%Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Page 1 of 12
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi
GENERAL INFORMATION
01
Project Name
Jaclin C. Smith Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
Lions Gates #10
04
A City
La Quinta
05
Standards Version
Compliance 2015
06
Zip code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-3 (651)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.3
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
120 .
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
5092
15
Number of Zones
4
16
Slab Area (FT2)
5092 .
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
N/A
21
Glazing Percentage (%)
18.8%
COMPLIANCE RESULTS
01
Building Complies Wdomputer Performance
02
This building incorpo atesfeatu s; that;reVire field testing and/dr verification by a certified HERS�at�ertunderthe supervision of a CEC-approved HERS provider.
03
This building incorporates one o�r- moie Special._Featuees'shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(kTDV/ft)
Standard
Design
Proposed.
Design
Compliance
Margin
Percent
Improvement
Space Heating
4.84
4.83
0.01
0.2%
Space Cooling
126.12
124.99
1.13
0.9%
IAQ Ventilation
1.30
1.30
0.00
0.0%
Water Heating
5.04
5.62
-0.58
r%1TV 1lt5°
Photovoltaic Offset
---
0.00
0.00--
-..
cs III rnln _ C
Compliance Energy Total
137.30
136.74
0.56 i
v
DATE
I
APT.
w4.l1. 0 Registration Number: 214-No092597B-000000000-0000 Registration Date/Time: _ 2014-12-04 14:40:57 HERS-Provi
�C6ICERT0S in
CA BuildingEnergy Efficient Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Repo���OP A2 V"Uuip64M. --
-
r � ter,•,-..- -_ . ' . _—•--•=:.-+�•
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Jaclin C. Smith Residence - Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Page 2 of 12
Calculation Description: Title 24 Analysis - Input File Name: Smith Res -Lions Gate-STRACTS-14.icml
ENERGY DESIGN RATING_£
This is the sum of the annual TDV energy 4onsumption for energy use components included in the performance'compliance app oach'ia ttie Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components.not regulated by Title 24 Part.6 (such as domestic appliance"s and__cconsumerelectromcs) and accounting for the annual TDV energy offset by an
on -site renewable energy system.-
Reference Energy Use
"z f $ ;Energy D ' I' `Rating
Margin
Percent Improvement '
_ Total Energy (kTDV/f2)"
' 174.32 " '�
ti .:173 76
. 0.56
`. 0.3%
t
. r
. " includes calculated Appliances and Miscellaneous Energy Use (AMEU) _ +, -5 : • i - ,
.+ , ♦ �• F
BUILDING - FEATURES INFORMATION ,
01
02
03 _
04
05 ,.
06
•07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Jaclin C. Smith Residence
5092
1 -
12
4`
Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 -
L. I I Y U i— L/-! 'lid U 11N I/ O
BUILDING &SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
f DATE BY
p _
HE-R-S4�Mer.
Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CFI R-PRF-01
Page 3 of 12
ZONE INFORMATION
01
02
03
04
05-
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Bedroom
Conditioned
HVAC 1 masterl
871
14
DHW Sys 1
Kitchen Dining
Conditioned
HVAC 2 kit2
864
14
DHW Sys 1
Greatroom & Hall
Conditioned
HVAC 3 & 4 great3
2245
14
DHW Sys 1
Bedroom 2,3 & 4
Conditioned
HVAC 5 bed4
1112
14
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
30d Wall
Master Bedroom
R721 Wall (W.21.2x6.16)
30 _
Right
378
40
90
120d Wall
Master Bedroom
R-21 Wall (W.21.2x6.16)
120
Front
378
0
90
210d Wall
Master Bedroom
_ R-21 Wall (W.21.2x6.16)
_ 210
Left
1210
57.9
90
300d Wall
�Master Bedroom ` '.
t< R-21 Wall (W 21 2x6.16)
tf'300V
Bade
672
46
90
Roof
(' Maste�Bedrdom'" �
�R-38 Roof Attic''
= A
871
30d Wall 2
%,W KdchenLDirnng !
'
30 . ti��;
'+�' Right
462
102.4
90
300d Wall 2
Kitchen Dining i
R=21 Wall (W.21.2x6.16)
300
Bade
462
76
90
Roof 2
Kitchen Dining
R-38 Roof Attic
864
30d Wall 3
Greatroom & 11611
R-21 Wall (W.21.2x6.16)
30
Right
210
13
90
E Wall
Greatroom & Hall
R-21_ Wall (W.21.2x6.16)
90
specify -
210
13
90
120d Wall 2
Greatroom & Hall
R-21 Wall (W.21.2x6.16)
120
Front
1650
183
90
S Wall
Greatroom & Hall
R-21 Wall (W.21.2x6.16)
180
specify -
378
0
90
210d Wall 2
Greatroom & Hall
R-21 Wall (W.21.2x6.16)
210
Left
210
25
90
W Wall
Greatroom & Hall
R-21 Wall (W.21.2x6.16)
270
specify -
210
18
90
300d Wall 3
Greatroom & Hall
R-21 Wall (W.21.2x6.16)
300
Bade
924
222
90
Roof 3
Greatroom & Hall
R-38 Roof Attic
2245
30d Wall 4
Bedroom 2,3 & 4
R-21 Wall (W.21.2x6.16)
30
Right
1386
C
T ION—
Registration Number: 214-No092597B-000000000-0000 Registration Date/Time:., 2014-12-04 14:40:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence CalculationDate/Time: 14:31, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xm1
CFI R-PRF-01
Page 4 of 12
ATTIC
01
02
03
04
05
06
07
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons
3
0.1
0.85
No
No
Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time:2014-12-04 14:40:57,
CA Building Energy Efficiency Standards - 2013 Residential Compliance • Report Version- CF1R-10172014-651
f CITY OF LA QUINTA
I BUILDING & SAFETY DEPT.
4, PROVED
FO.=i CONSTRUCTION
DATE BY
i
HERS Provider: CaICERTS inc.
Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CFI R-PRF-01
Page 5 of 12
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
NEW
Window
30d Wall (Right-30)
-
-
1
40.0
0.28
0.28
Insect Screen (default)
NEW 2
Window
210d Wall (Left-210)
---
--
1
4.0
0.28
0.28
Insect Screen (default)
NEW 3
Window
210d Wall (Left-210)
-
--
1
6.0
0.28
0.28
Insect Screen (default)
NEW 4
Window
210d Wall (Left-210)
-
-
1
3.9
0.28
0.28
Insect Screen (default)
NEW 5
Window
210d Wall (Left-210)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 6
Window
210d Wall (Left-210)
-
-
1
7.5
0.28
0.28
Insect Screen (default)
NEW 7
Window
210d Wall (Left-210)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 8
Window
210d Wall (Left-210)
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 9
Window
210d Wall (Left-210)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 10
Window
210d Wall (Left-210)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 11
Window
_ _ 300d Wall.(Bacl-30t)),
1
6.0
0.28
0.28
Insect Screen (default)
NEW 12
Window f
" r t' 3ddd-Wall (Back=30U)
�-
1
40.0
0.28
0.28
Insect Screen (default)
NEW 13
Window
i30d Wall 2 (Right=30)'�f_
-
�'=-�
��1
�102.4
0.28
0.28
Insect Screen (default)
NEW 14
Window �..¢�
'.;�d "300d Wall 2.(Bacli-300)--7
76.0
0.28
0.28
Insect Screen (default)
NEW 15
Window
30d Wall 3 (Right-30)
- -
--
1
13.0
0.28
0.28
Insect Screen (default)
NEW 16
Window
E Wall (- specify -90)
---
-
1
13.0
0.28
0.28
Insect Screen (default)
NEW 17
Window
120d Wall 2 (Front-120)
--
--
1
11.0
0.28
0.28
Insect Screen (default)
NEW 18
Window
120d Wall 2 (Front-120)
-
1
11.0
0.28
0.28 1
Insect Screen (default)
NEW 19
Window
120d Wall 2 (Front-120)
-
--
1
11.0
0.28
0.28
Insect Screen (default)
NEW 20
Window
120d Wall 2 (Front-120)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 21
Window
120d Wall 2 (Front-120)
--
-
1
25.0
0.28
0.28
Insect Screen (default)
NEW 22
Window
120d Wall 2 (Front-120)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
NEW 23
Window
120d Wall 2 (Front-120)
-
-
1
13.0
0.28
-2
nse een RN
Or
NEW 24
Window
120d Wall 2 (Front-120)
-
-
1
13.0
0.2,8.2
ristAcrAU
NEW 25
Window
120d Wall 2 (Front-120)
-
-
1
13.0
0.28
UR-3I,
G Innsec er ( e
NEW 26
Window
120d Wall 2 (Front-120)
-
-
1
13.0
0.2b
0..128P
PI`' S ri d fa It)
NEW 27
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
_28�@�e
NEW 28
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.2d
0.28
Insect Screen (default)
NEW 29
Window
120d Wall 2 (Front-120)
--
-
1
6.0
0.28` r
`T 0.28
Insect ;�peen default
Registration Number: 214-No092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Calculation. Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CFI R-PRF-01
Page 6 of 12
NEW 30
Window
120d Wall 2 (Front-120)
-
--
1
6.0
0.28
0.28
Insect Screen (default)
NEW 31
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 32
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 33
Window
120d Wall 2 (Front-120)
-
-
1
6.0
0.28
0.28
Insect Screen (default)
NEW 34
Window
120d Wall 2 (Front-120)
--
--
1
6.0
0.28
0.28
Insect Screen (default)
NEW 35
Window
210d Wall 2 (Left-210)
----
---
1
12.5
0.28
0.28
Insect Screen (default)
NEW 36
Window
210d Wall 2 (Left-210)
--
--
1
12.5
0.28
0.28
Insect Screen (default)
NEW 37
Window
W Wall (- specify -270)
-
-
1
18.0
0.28
0.28
Insect Screen (default)
NEW 38
Window
300d Wall 3 (Back-300)
24.0
8.0
1
192.0
0.28
0.28
Insect Screen (default)
NEW 39
Window
300d Wall 3 (Back-300)
-
-
1
30.0
0.28
0.28
Insect Screen (default)
NEW 40
Window
30d Wall 4 (Right-30)
-
---
1
6.0
0.28
0.28
Insect Screen (default)
NEW 41
Window
30d Wall 4 (Right-30)
-
---
1
30.0
0.28
0.28
Insect Screen (default)
NEW 42
Window
30d Wall 4 (Right-30)
---
--
1
6.0
0.28
0.28
Insect Screen (default)
NEW 43
Window
30d Wall 4 (Right-30)
--
---
1
6.0
0.28
0.28
Insect Screen (default)
NEW 44
Window
30d Wa11.4,(Right,30) �r-s+e*�
_
1
6.0
0.28
0.28
Insect Screen (default)
NEW 45
Window
'! ^� 3l)d Wall 4 (Ri66t-30) , `�--
, ; '
1
6.0
0.28
0.28
Insect Screen (default)
NEW 46
Window t
F �30d61Nal14 (Right 30)'Y.
'_=. f
trn,rl /m
1 6.0
0.28
0.28
Insect Screen (default)
NEW 47
Window
`>,,,'� " ' `120d 1Nall.3-(Front-120) '" s ' , yK
- =`=
,
' *yf �1,[,�a
3.9
0:28
0.28
Insect Screen (default)
NEW.48
Window
120d Wall 3 (Front-120)
----
---
1
42.0
0.28
0.28
Insect Screen (default)
NEW 49
Window
210d Wall 3 (Left-210)
--
--
1
12.5
0.28
0.28
Insect Screen (default)
NEW 50
Window
210d Wall 3 (Left-210)
-
-
1
25.0
0.28
0.28
Insect Screen (default)
NEW 51
Window
210d Wall 3 (Left-210)
-
-
1
12.5
0.28
0.28
Insect Screen (default)
DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
S Wall
20-w
r Q
t_. . . - - -
OVERHANGS AND FINS ' tSUI ED II 71
_
01
02
03
04
05
06
07
08
09
10
11 A�12 l' I
4
Overhang
Left Fin I
FUK URig
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht
Depth
Top Up
DistL
Bot Up
r.RVt;h
Top Up
'st R
Bot Up
NEW 38
18
0.1
18
18
0
0
0
0
0
0
0
Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Calculation. Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi
CFI R-PRF-01
Page 7 of 12
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
2x4 Top Chord of
Cavity/Frame: no insul. /2x4 Top Chrd
Roof Truss @ 24 in.
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-9.1 / 2x4
R-38 Roof Attic
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
-
Cavity/ Frame: R-21 / 2x6
R-21 Wall (W.21.2x6..16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
Exterior Finish: Wood Siding/sheathing/decking
SLAB FLOORS
0.1
02 '
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Covered Slab``
Master Bedroom
None
0.8
No
Covered Slab 2
`, Kitchen Dining,;'
8641^''s %i
k,44:
None
0.8 ,
No
Covered Slab 3
y\ } Greatroom &"Hall ""s �I
i'•'.e iRr' F.. !4'
�•� , 2245 ' `-erg}
'3�.
170 , •f� }y
v
None
0.8
No
Covered Slab 4
` ` Bedroom 2 3 t£'4'� ,, .
*' 1112
151 "
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION s
01
02
03 ,
04
Quality Insulation Installation (QII)
I. Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Not Required
—
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of -(seat p
p: of FFa� Ion' 'TJ
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
I r�l NI
R RAFM pEP
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
-
r-3 r0n=
Registration Number: 214-No092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 -
FOR CONSTRUCTION
DATE BY
HERS Provider: CaICERTS inc.
Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input file Name: Smith Res -Lions Gate-STRACTS-14.xmi
CF1 R-PRF-01
Page 8 of 12
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
.(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A.
N/A
N/A
N/A
N/A
N/A
DHW Sys 1 - 1/2
N/A
N/A
N/A
N/A`
N/A
N/A
HVAC SYSTEMS
01.021Y
y'
`03
04
05
06
07
f
Heating"Systee `
Ir Cooling System
Distribution..
Floor Area
Name
System�Type..
Name Ducted
Named r?' Ducted
r
System
Fan System
Served
# ,�
e,
HVAC 1 masterl
Other Heat/Cool }
Heating Component 1
_
Yes
_ ._, . „
Cooling Component 1 .
Yes
Air Distribution
871
System 1
HVAC 2 kit2
Other Heat/Cool
Heating Component 2
Yes
Cooling Component 2
Yes
Air Distribution
System 2
864
HVAC 3 & 4 great3
Other Heat/Cool
Heating Component 3
Yes
Cooling Component 3
Yes
Air Distribution System System 3
HVAC 3 & 4 great3
Other Heat/Cool
Heating Component 3
Yes
Cooling Component 3
Yes
Air Distribution System System 3
HVAC 5 bed4
Other Heat/Cool
Heating Component 4
Yes
Cooling Component 4
Yes
Air Distribution
System 4
1112
Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
HERS Provider: CaiCERTS inc.
Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith' Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi
CF1 R-PRF-01
Page 9 of 12
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntrlFurnace - Fuel -fired central furnace
80 AFUE_
HVAC - COOLING SYSTEMS
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
'Cooling Component 1
SplitAirCond - Split air conditioning
13
16
No
No
Cooling Component
system
1-hers-cool
Cooling Component 2
SplitAirCond - Split air conditioning
13
16
No
No
Cooling Component
system _
x..+ .,t--T.
2-hers cool
Cooling Component 3
SplitAirCond -' Split air conddi&ir g
r
13
a "16 0.`
No
No
Cooling Component
ste
- s Y xm` : }
1f
a .-
.�.
3-hers-cool
Cooling Component 4
S IitAirCond - S Id`airaohAlhiornn
p p� 9
2
13.rf1
" t
s 16
t` ##�
No
No
CoolingComponent
p
system x.
,
F -
4-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02,
03-
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
'350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
uice
CITY OF, LA UUIN I /A
BUILDING & SAFETY DEPT.
PIPF"" ROVED
FOR CONSTRUCTION
DATE BY
Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 R Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014=651 Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 -
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Page 10 of 12 '
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi 6
HVAC - DISTRIBUTION SYSTEMS '
01
02
03
04
05
106
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution
System 1-hers-list
Air Distribution System 2
Ducts located in attic
Sealed and tested
8
Attic
Attic
None
Air Distribution ,
•t
System 2-hers-list
Air Distribution System 3 "
Ducts located in attic
Sealed and tested
T 8 ` -
F Attic
Attic
None y
Air Distribution
System 3-hers-dist
a
Air Distribution System 4
Ducts located in attic,
Sealed and tested
8
Attic. -�
Attic. „ ,
N_
one
-° Air Distribution
System 4. hers -disc'
'.
HVAC DISTRIBUTION -HERS VERIFICATION ,.
01
02:.:
03„
04
05 ..
06 -
07 _
'
Duct Leakage
' °
r
Verified' Duct Design
Low -leakage -
Name
Verification F:
Duct LeaTare % a ,`4' tVe^rfed
9 g ( )
4 �.._, Duct Location
Return Supply ,
Air Handler
' Air Distribution System
Required
" j
rw� 60
-�
,Not ui
.l2egred..
Not Required
Not Required1-hers
dist
o
Air Distribution System'-
"a. '''
Required
k3,, x'"' `:v.:
N+`" ... '
6 0
a„-1;"4.4.. '�4+.
Not Required
'Not Required
Not Required
2-hers-dist
;
1T _
Air Distribution System
3-hers-dist
"' =`;
' Required
.. >- 6 0
': "' a s•
Not Required
' '
Not Required
`
Not Required
-
Air Distribution System
Required
6.0
Not Required
Not Required ::
Not Required
-
4-hers-dist
-
•'+ r
a
S.
HVAC -
FAN, SYSTEMS-
01
02
03
04
Name
Type
-Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1,
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
u f I T AvAE F - e -
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58 !
UI UI WXc e _ .
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
A HPe Fa°n 4- a ��f
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
Registration Number: 214-N0092597B-000000000-0000 ,
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2014-12-04 14:40:57
Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-12-0414:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE .COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014
Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CFI R-PRF-01
Page 11 of 12
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58.
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
D'WellingUnit
148.42
0.25 ' .
Default
0
Required
COOLING VENTILATION -
01
; 02
03
04
Name
Cooling Vent CFM
Cooling Vent Watts/CFM
Number of Fans
WH Fan 1
/n"" �s61 x s,z
?a _. 0.52459
1
�•�_
WH Fan 2a p,
r
`%'1'.; *>61t, ,, � ; /
0.52459,
1
WH Fan 3
61' ! i .,
.. ir. "� .f'f '0.524593
1
:+.�,r r
WH Fan
�� ;.*' "' 9 r .6,1 �'` ._ ';,"" .:' $
""a�;k�q t+ 4r'ty''0:52459
1
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
�
P"ROVED
FOR CONSTRUCTION
f
DATE BY
Registration Number: 214-NO09259713-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-04 14:34:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Jaclin C. Smith Residence Calculation DatefTime: 14:31, Thu, Dec 04, 2014 "
Calculation Description: -Title 24 Analysis ` Input File Name: Smith Res -Lions Gate-STRACTS-14.xml
CF1 R-PRF-01
Page 12 of 12 ,
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete. * .
Documentation Author Name:' , -
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc. -
2014-10-31 07:58:37
Address: �. • ,- ' -� z�
CEA/HERS Certification Identification (If applicable): , , „-
77085 Michigan Drive
City/State/Zip:.. ..
Phone:
Palm Desert, CA 92211 . , '° - ;
: (760) 200-4780 ? w• + r
RESPONSIBLE PERSON'S DECLARATION STATEMENT • " - ••, s ' �• i, �- �. ' _ x . ' . , '
I certify the following under penalty of perjury, under the laws of the State of California: r'L . " • ' • , z - r P`
1- 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for thelbuilding design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title'24, Part•1 and Part 6 of the California Code of. • .:
{• •' Regulations. ' ...�, , r, ;. ', - .', • - ,-
3. The building design features -or. system.design features identified -on this Certificate of Compliance are _consistent,with the information provided on other applicable compliance documents
.-.� � .'vat. , - `m •. � FN `k .a..' h a .�
• worksheets, calculations, plans and specifications submitted tb� thre enforc�ement�agency for approval?with this building permit application.
Responsible Designer Name:
„ • ti`
�x...x
�'�w.
Responsible Designer Signature:
ti .
�' J•Y
Tim Scott F r
IGIJl/�GOG!/
5'�.rrf"�'�
Company:
y24,
Date Signed ,.
- a
Scott Design and Title Inc.-
2014-12-04'14 40:57 ` 4
Address: ,. z c , ; I �;
t ;s:
License:.
77085 Michigan Drive ..s
na
City/State/Zip: „ ! ..
Phone:
Palm Desert, CA 92211 F `., -` �•
(760) 200-4780
t _
... =r-• . • f ` . -- •,' M1' ate. -.- +_,h> � . - .' -1. — � � _ - - `'
CITY O1= LA.Q, UINTA
BUILDING &SAFETY'DEPT.
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibrlrt f r r
` - FOF;rMION
information.. -
" [DATE BY
Registration Number: '214-N0092597B-000000000-0000 - Registration Date/Time: 2014-12-04 14:40:57 ' HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:34:02 .