BRES2014-1143C aNN1��il/ `•Cf/ '�/ VOICE (760) 777-7125 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 1/21/2015 Application Number: BRES2014-1143 Owner: Property Address: 80871 VISTA LAZO JACLIN C. SMITH APN: 762250010 302 E. WEDGEWOOD ns- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed'under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 769229 , Date: / At m; Contractor' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, -the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to w the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (760)771-9954 Llc. No.: 769229 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th#wprk for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 1700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with hose provisions. Date: r Zi ? Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and.the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned property for inspection purposes. Date: I !1 f , Signature (Applicant or Agent): FINANCIALe• e �F DESCRIPTION;,a3 t ACCOUNTS � aQTY AMOUNTa s PAIDr PAID DATE oz <� . 3 ,w,; ART IN PUBLIC PLACES -,RESIDENTIAL 270-0000-43201 0 $382.17 $382.17 1/15/15 `PAID BY # ,iz.�METHOD�' '. RECEIPT#� e,� CHECK# CLTD BY411 y e#a , c' JACLIN C. SMITH CHECK R3425 7021 AZA . Total Paid forART IN PUBLIC PLACES - AIPP: $392.17 $382.17 g $ `=: DESCRIPTION �' `���° �� � °` �� � ACCOUNT � � {{ �CtTY ��� AMOUNT�e '18` � PAID*';� a PAID DATE: f' <„is„r ',;,. BSAS SB1473 FEE 101-0000-20306 0 $15.00 $15.00 1/15/15 PAID<BY' t 44 ,, RECEIPT,# Mkt.... CHECK # ' CLTD 1 w .'METHOD �.a , JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $15.00 $15.00 S� DESCRIPTION: fzq " r ' tACCOUNT "�iii Y`CtTY 'AMOUNT PAID PAID DATE: f DIF - CIVIC CENTER 252-000043200 0 $942.00 $942.00 1/15/15 1 { b °iSx {•'i+'k� Y A �• :. 4 Hi C PAID'BY sY S 3R. p,k yi - .- was k aMETHOD .'R .� .1.. ECEIPT: CHECK BY �z s< �'� _ .L x R JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTIONP }ACCOUNTz w,;QTYf w 'AMOUNT s *z,s? PAID PAIDDATE _@ t".2 if ff' G uS.�e °Il.i f a 7•,( Sr. a` �! .% a.ji( DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 1/15/15 INr, z; PAID'BY cam,;$ r� ?s METHOD `�, ,. * ;.RECEIP,T;# ,. * aCHECK#+z C LT D BYE °..�u <� '�•f .r .•- .. .� ��s _ a.,:, .�>x. JACLIN C. SMITH CHECK R3425 7021 AZA F` ,r ACCOUNT QTY "_� AMOUNT a"z9 'r. PAID PAID DATE: a ,DESCRIPTION . DIF -FppIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 1/15/15 G L� S a > PAID BY hz P, L, S+� ;! y METHOD f S.wUr RECEIPT # f •14 CHECK # ' y.a: CLTD BY >' a F w n,< t.• tr JACLIN C. SMITH CHECK R3425 7021 AZA t a '. ; ACCOUNT ., QTY AMOUNT�� ' PAID PA D'DATE r`& rDESCRIPTION a , t. ems;s�,•c 4 , , DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 1/15/15 PAID BY,{ �r s METHOD _ RECEIPT #�- CHECK # "' CLTD BY _ Jf JACLIN C. SMITH CHECK R3425 7021 AZA Y � DESCRIPTIONA,f:" " s ACCOUNT F.CZTY AMOUNT r PAID 4PAID'DATEa p :` DIF - PARK MAINTENANCE '256-0000-43200 0 $40.00 $40.00 1/15/15 "fz Q.PAID BY'a 3 x` METHOD k RECEIPT,# a �f ! Y CHECK CLTD BY ,ry JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTION E _ ��.� rACCOUNT 3z QTY=F "AMOUNTAN' z PAID j PAID DATE ;fir DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 1/15/15 PA16 � ;H RECEIPT# CHECK# CLTD BY JACLIN C. SMITH CHECK R3425 7021 AZA ` zfaDESCRIPTION * ` �j a 1, `ACCOUNT rt?� z, QTY `;, AMOUNT° t� PAID x PAID;DATE;; + DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $116.00 1/15/15 PAID BY i 4 _ ` METHOD '` + n'RECEIPT # z CHECK# �. CLTDBY s _ ,> r:;•.-°:_... .- .,. JACLIN C. SMITH CHECK R3425 7021 AZA r$ DESCRIPTION �' " <:ACCOUNT a 'QTY AMOUNT` '"� z r�' PAID ' PAID DATE: >. a E_ r. DIF -.TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 1/15/15 L } , 5,4 h�'�PAID"BY --METHOD RECEIPT# z CHECK#=" �'CLp TDBY ¢: JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid forDIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 M ?DESCRIPTIONS a;, ACCOUNTt s°{€`AIIIIOUNTh PAID, PAIDDATE' .i .F°Yiy.G..<:' i• fix... -. �y..-...+a+`� r' `'K b r.e , VY ;QTY TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 1/15/15 Y F 4 � PAID BY4 ��,��S * 'S 'T 3 � �'.,.'§y METHOD is � 't '+r -. t '4 .'�. -- �. `RECEIPT # Y{. ':T CHECK # CLTO BY ...�, , 4 JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTION . $ t ACCOUNT >3 QTY �VAMOUNT '_ t -� PAID PAID DATE } fi=.. TEMP POWER SERVICE PC 101-0000-42403 0 $16.92 $16.92 1/15/15 t BYF, +� RECEIPT #� #�i CLTD BYE, �_ F�,PAID of 2 *METHOD iz .Ns Y �` i�'CHECK JACLIN C.'SMITH CHECK R3425 7021 AZA Total Paid for ELECTRICAL: $41.09 $41.09 a DESCRIPTION .+ a `;. ACCOUNTS { ..t € AMOUNT a » L PAID , s f . PAID:,DATE° t e .. • '`QN? > RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $73.98 $73.98 1/15/15 PAID.BY k " a METHOD r * k f ' CHECK # , t CLTD BY " z , 3 <3 ^RECEIPT#, :n: JACLIN C. SMITH CHECK R3425 7021 AZA 3, DESCRIPTION ; <- ` ACCOUNT s t*AMOUNT PAID '° _ +PAIDDATE w z is 5 , .:QTY RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $30.48 $30.48 1/15/15 xPAID'BY + ' '� �a » ` ;Vw n METHOD K"1�� ;,RECEIPT # ' CHECK # "CLTD BY r'x'g JACLIN-C. SMITH CHECK R3425 7021 AZA b x `V DESCRIRTION �t ACCOUNT }: £aQN YAMOUNTS a° PAID ' i s PAID OATEV, E sa' 1 4a:` es : RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.01 1/15/15 'PAID BY ¢ t A METHOD ' w RECEIPT # ` ; CHECK # €CLTD BY ;X Y%`., ,;.'. E�.: r. D i:;::'..:•. . d ..,F �?' . >- :..*,.: ... k ,. :.'h .. 6..ck :ii.5' P fi}.=51'�.',. JACLIN C. SMITH CHECK R3425 7021 AZA bESC.RIPTION a` '`QTY a AMOUNT 6 PAID°- PAID -DATE: 4 } s RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 i 1/15/15 "c ` PAID: BY CHECK # CLTDBMETHOD, Yf' k z •g JACLIN C. SMITH CHECK R3425 7021 AZA -Total Paid for ELECTRICAL - NEW CONSTRUCTION: $297.35 $297.35 [. DESCRIPTION r ACCOUNT' , e QTY�AMUUNT `- s: PAID ' PAIDDATE 7 �� RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 $143.00 1/15/15 :.� METHOD p' x fb,' RECEIPT # .-- CHECK # ' CLTD BYt JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid forGRADING: $143.00 $143.00 DESCRIPTIONul. ) ACCOUNTS QTY AMOUNT {' PAID,, t r PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $181.30 $181.30 1/15/15 u t PAID.BYz < METHODS RECEIPT # CHECK # ` CLTD BY ,; r g JACLIN C. SMITH CHECK R3425 7021 AZA .DESCRIPTION ` x ,ACCOUNT QTY AMOUNT � .x PAID PAID DATE' „ w v # CONDENSER/COMPRESSOR PC 101-0000-42600 0 $120.85 $120.85 1/15/15 " k PAID: BY ; f r� =METHOD ''� $.`RECEIPT # ` ` CHECK # u '' CLTD By s u:' *`t ti s �i,a JACLIN C. SMITH CHECK R3425 7021 AZA t. z 'DESCRIPTIONCCOUNTS QTY AMOUNT PAID `PAIDDATE _w - EXHAUST HOOD 101-0000-42402 0 $24.18 $24.18 1/15/15 n #PAID:BY s Y METHOD , ;RECEIPT:# r CHECK # CLTD BY,',,:' _-. JACLIN C. SMITH CHECK R3425 7021 AZA y `FL DESCRIPTIONYACCOUNT E, QTY AMOUN T PAID PAID DATE. ' .. ., .. o r v.. .. -.:x. EXHAUST HOOD PC , 101-0000-42600 0 $9.66 $9.66 1/15/15 :ry PAID BY METHOD t�' s RECEIPT # ` # CLTD BY T e - n s ,CHECK JACLIN C. SMITH CHECK R3425 7021 AZA r ,'­DES'CRIPTION ACCOUNT QTY AMOUNT PAID ,_ �PAIDDATE FURNACE 101-0006-42402 0 $181.30 $181.30 1/15/15 METHOD RECEIPT # CHECK # CLTD BY h 4 JACLIN C. SMITH CHECK R3425 7021 AZA X DESCRIPTION ACCOUNT ` QTYr AMOUNT PAID PAIDDATE FURNACE PC 101-0000-42600 0 $120.85 $120.85 1/15/15 PAID' BY ' METHOD ` wrRECE1PT # CHECK # C LTD BY ' x';' , JACLIN C. SMITH CHECK R3425 7021 AZA E ;DESCRIPTION a :'-A000,UNT QTY z��AMOUNT .�: °PAID =, PAID DATE; VENT FAN 101-0000-42402 0 $72.54 $72.54 1/15/15 E PAID BY _ METHOD ::. u� RECEIPT #'. CHECK # CLTD BY „ -. . .: w. ... 3 , JACLIN C. SMITH CHECK R3425 7021 AZA' ,': �_ DESCRIPTION ACCOUNT Fy QTY AMOUNT j; PAID PAID, DATE .: ..., VENT FAN PC 101-0000-42600 0 $28.98 $28.98 1/15/15 'E' PAIOyBY' pe METHOD" ` RECEIPT. # CHECK' CLTDBY I JACLIN C. SMITH CHECK R3425 7021 AZA jt Total Paid forMECHANICAL: $739.66 $739.66 DESCRIPTION z ACCOUNTS QTY a; AMOUNT-. ! PAID ' PAID DATE- y MULTI -SPECIES RESIDENTIAL 0-8 UNITS 101-0000-20310 0 $1,292.00 $1,292.00 1/15/15 $Y h MMETHOD CHECK # CLTD BY `. k .RECEIPT.#' JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid for MULTI -SPECIES RESIDENTIAL $1,292.00 $1,292.00 DESCRIPTION `< r = ACCOUNT „6 AMOUNT, PAID PAID DATE ;°CITY w NEW CONSTRUCTION PERMIT 101-0600-42400 0 $667.25 $667.25 1/15/15 PAID.BY r '� :; ? °METHOD § RECEIPT # CHECK # CLiD BY 1E :' +f JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid for NEW CONSTRUCTION PERMIT: $667.25 $667.25 .DESCRIPTION ACCOUNT AMOUNT , : PAID PAID PATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,428.60 $1,428.60 1/15/15 ' Al BY METHOD RECEIPT># CHECK JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTION, ' : ACCOUNT QTY AMOUNT PAID PAID DATE' ,.,,. „.k..., NEW CONSTRUCTION PLAN CHECK I 101-0000-42600 0 $1,400.00 $1,400.00 10/22/14 x = PAID ,BY w_ ` METHOD RECEIPT:# CHECK # CLTD.BY, ` `v ALBERS CONSTRUCTION CO INC CHECK R2311 3839 SKH FDESCRIPTION = QTY AMOUNT €� PAID` S PAID'DATE ... ` Y'ACCOUNT. r` NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $28.60 $28.60 1/15/15 . `�e, PPAID BY METHODw .RECEIPT#A x 1 CHECK #kCLTD BY , JACLIN C. SMITH CHECK R3425 - 7021 AZA Total Paid for NEW CONSTRUCTION PLAN CHECK: $2,857.20 $2,857.20 °#DESCRIPTION �a A000UIVT3t° R ``QTY AMOUNT = f PAID PAID: DATE; , . , BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 1/15/15 PAID BY x '�<.; F'�_�"•, METHOD �eRECEIPT F _`�-<.r� JACLIN C. SMITH CHECK R3425 7021 AZA' t ' DESCRIPTION > 3 'ACCOUNT ;QTY�AMOUNT 'kv PAID AID DATE - . ¢ ..,. $� BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 1/15/15 #' r z z3 PAID BY '� 4�, METHOD * RECEIPT:# x• "' CHECK CLTD BYx �. .'Miff?! JACLIN C. SMITH CHECK R3425 7021 AZA ' °DESCRIPTION �� ACCOUNT T AMOUN'' XPAID PAID DATE ¢„ram a, 4 BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 1/15/15 k " k".. t,.m PAID BY ; r' :METHOD RECEIPTz# �s 2 14 CHECK# CLTD BY ..• '(i'= [ ^4 4 Y..:''Y x ..: ..°"' K xFa.%, :&i N yt3� JACLIN C. SMITH CHECK `` R3425 7011 AZA r; ,* DESCRIPTION ACCOUNT CITY AMOUNT - PAID' ATE., Y� ,nPAIUE BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 1/15/15 1� PAID BY �� � ;�>�' METHOD' r g w $ :RECEIPT #•. CHECK # CLTD BY ; JACLIN C. SMITH CHECK R3425 7021 AZA Ez 4 DESCRIPTION y E QTYw N'AINIOUNT €� PAID , PAID DATE, g .;g p` € .A000UNTs a. F FIXTURE/TRAP 101-0000-42401 0 $278.07 $278.07 1/15/15 t 'PAID BYE METHOD n $" ° ` r t RECEIPT ` CHECK #z`# CLTD BY .,1_.&�i e f s _ JACLIN C. SMITH CHECK R3425 7021 AZA .DESCRIPTION:{ $'� 4," ACCOUNT ` & ,QTY., AMOUNT :>F PAID tPAID DATE' €°:" .. FIXTURE/TRAP PC 101-0000-42600 0 $278.07 $278.07 1/15/15 � 4 PAID BYE METHOD RECEIPT CHECK # BY _. -'Y e " ^" ik -.. � "zi i a .:'rc ,. •f"•r . :.....i_ . � .4As.-fu -q.. , IrP, �p �� P:; ,CLTD JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTION ,'�§ ACCOUNTS QTY'' AMOUNT f PAID ti E' PAID DATE: _ GAS SYSTEM, S+ OUTLETS 101-0000-42401 0 $36.26 $36.26 1/15/15 QMETHOD "r fRECEIP7ACHECK# CLTOBYe. e a. .:. JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTION ACCOUNT, ' ° QTYk , AMOUNT py PAID g PAID;DATE .. ? . GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $24.17 1/15/15 ca METHOD;RECEIPT.# ` i' $ CHECK # * CLTD BY x'L ,_, t� , ,:.,.• �. ,.+. JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTION!i`, , str e ACCOUNTS ? QTY; `:��� AMOUNT PAID PAID DATE �r jibF rr k ..` WATER HEATER/VENT 101-0000-42401 0 $36.27, $36.27 1/15/15 PAID'BY ET. METHOD';RECEIPHECK# CLTD BYE: zx JACLIN C. SMITH CHECK 113425 7021 AZA • � . 1 7 Ate. DESCRIPTION : ACCOUNQ (p AMOUNT a " gPAID ;xt�, $PAItD A E r� a r �` ry . ., WATER HEATER/VENT PC 101-0600-42600 0 $21.75 $21.75 1/15/15 PAID�BY'� s s `METH( RECEIPT . ; CLTD BY _. :+• Y, ,CHEC JACLIN C. SMITH CHECK R3425 7021 AZA DESCRIPTIONav`;€� ACCOUNT 4zt1CZTY'}>F ,AV OUNT;P PAID s PAID<DATE. r t ..�.w WATER SYSTEM INST/ALT/REP �101-0000-42401 0 $12.09 $12.09 1/15/15 BY METFIOD7 ° �Is � RECEIPT,#r s CHECK #x CLTD BY „fA aPAID r 4 4 > E JACLIN C. SMITH CHECK R3425 7021 AZA G DESCRIPTIO CfTY €* PAID. � �rACCOUNT�=� r 4AMOUNT`f _ k. LPAIDyDATE WATER SYSTEM INST/ALT/REP PC- 101-0000-42600 0 $12.09 $12.09 1/15/15 PAIDBY METH.OD �3s RECEI CHECKy#�f+ CLTD BY j _�. JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid forFLUMBING FEES $739 87 $739.87 a DESCRIPTION-.,. �' ' `r n,�:a <QTY� ,.'x AMOUNT e i X' PAID PAID DATE; ..: :::"? AACCOUNT :... _ _.:. .,. r. .. SMI - RESIDENTIAL 101-0000-20308 0 $45.87 $45.87 1/15/15 METHOD `, �,% RECEIPT:#p* CHECK # 's 4 CLTD BY, `4 ry, ;* JACLIN C. SMITH CHECK R3425 7021 AZA Total Paid forSTRONG MOTION INSTRUMENTATION SMt $45.87 $45.87 DESCRIPTION; AMOUNT PAID PAID`DATE z,µACCOUNT� V'4TY * SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $1,837.44 1/15/15 PAID By;s METHOD r 'a RECEIPTt#+> CHECK # CLTD BYE . _t " r.> a4'•': ," JACLIN C. SMITH CHECK R3425 • 7021 AZA Total Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44 TOTALS:•0 $15,951.90 i . • ess Summary,, .83 s %jApplie( to Approvetl,,,, CHRONOLOGYTYPE<. t ACTION;DATE. =Y COMPLETION DATESm, NOTES �' tt �STAFF_NAME P. r PLAN CHECK COMMENTS .FROM CONSULTANT ' µ� KAY HENSELM - 11j14/2014 11/14/2014 _ STRUC RFC 11/13/14 RECEIVED - PLAN CHECK COMMENTS 'FROM CONSULTANT KAY HENSEL . . - 1/12/2015 1/12/2015 STRUC APP 1/12/2015 _ RECEIVED i PLAN CHECK PICKED UP PHILIP JUAREZ 11/14/2014• 11/14/2014 MR. ALBERS PICKED UP. PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 12/29/2014 12/25/2014 RECEIVED CALLED ALBERS CONSTRUCTION CO. INC. @ 760-774-8787, TO TELEPHONE CALL JIM JOHNSON 11/14/2014 11/14/2014 INFORM THEM PLANS ARE READY FOR CORRECTIONS 1$T.PLAN CHECK. - l ' Printed: Wednesday, January 21, 2015 4:31:14 PM 1 of 6 SYSTEMS CALLED ALBERS CONST. @760-774-8787 PLANS READY TO ISSUE. ITEMS NEEDED P.M. 10, SCHOOL FEES, GRAND DEED, TELEPHONE CALL JIM JOHNSON 1/13/2015. 1/13/2015 HOA LETTER,GRADING PLAN NOT SIGNED, CONTRACTORS LIC. NEED S TO BE UPDATED. CONDITIONS . ..... CONTACTS T', 2 OFARESSI: APPLICANT ALBERS CONSTRUCTION CO INC P 0 BOX 238 LA QUINTA CA 92247 (760)771-9954 'CONTRACTOR ALBERS CONSTRUCTION CO INC P 0 BOX 238 LA QUINTA. CA 92247 (760)771-9954 OWNER 'JACLIN C. SMITH 302 E. WEDGEWOOD SPOKANE WA 99208 (760)771-9954. . . ..... .... INFORMATION, MDESCRIPT 4�., A t , ID DATE4 ECEI ECK,#+ ET —B ART IN PUBLIC PLACES 270-0000-43201 0 .$382.17 $382.17 1/15/15 R3425 7021 CHECK JACLIN C. SMITH 'AZA. RESIDENTIAL Total Paid forART IN PUBLIC PLACES - AIPP: .$382.17 $382.17 BSAS SB1473 FEE.- 7-,101-0000-20306 -0 $15.00 $15.00 1/15/15 R342.5 7021 CHECK [TH. JACLIN C. SMITH AZA Total Paid for BUILDING STANDARDS ADMINISTRATION $15.00 $15.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0' $942.00' $942.00 1/15/15- R3425 7021 CHECK JACLIN C. SMITH AZA DIF - COMMUNITY 254-0000-43200 0 $129.00 $129.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA CENTERS DIF - FIRE PROTECTION 257-0000-43200- 0 $433.00 $433.00 1/15/15* R3425 7021 CHECK JACLIN C. SMITH AZA DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA DIF - PARK 256-0000-43200 0 $40.00 $40.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA MAINTENANCE DIF - PARKS/REC --7255-0000-43200 251-0000-43200 0 $2,048.00 $2,048.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA DIF - STREET F MAINTENANCE 0' T $116.00 $116.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Printed: Wednesday, January 21, 2015 4:31:14 PM 2 of 6 opwsysums 77 T;FM 7. CLTW DESCRIPTION iA E-RE EIP ECK-4M r R. ', DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Total Paid forDIF -'SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA TEMP POWER SERVICE 101-0000-42403 0 $16.92 $16.92 1/15/15 R3425 7021 CHECK 'JACLIN C. SMITH AZA PC Total Paid forELECTRICAL: $41.09 $41.09 RESIDENTIAL, EA. 101-0000-42403 0 $73.98 $73.98 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA ADDITION 1,0005F RESIDENTIAL, EA 101-0000-42600 0. $30.48 $30.48 1/-15/15 R3425 70 - 21 CHECK JACLIN C. SMITH AZA, ADDITION 1,000SF, PC RESIDENTIAL, FIRST, 101-0000-42403 0 $145.03 $145.03,', 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA 1,0005F RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 .$47.86 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA 1,000SF, PC r Total Paid fdrELECTRICAL - NEW CONSTRUCTION: $297.35 $297.35, RESIDENTIAL FINISH 101-0000-42600 0 $143.06 $143.00 1/15/15 1 R3425 70211. CHECK JACLIN C. SMITH AZA GRADING PC Total Paid forGRADING: .$143.00 $143.00 CONDENSER/COMPRES 101-0000-42402 0 $181.30' $181.30 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA SOR CONDENSER/COMPRES 101-0000-42660 0 $126.85 $120.85 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA SOR PC EXHAUST HOOD 101-0000-42402 0 $24.18 $24.18 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA EXHAUST HOOD PC 101-0000-42600 0 $9.66 $9.66 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA FURNACE 101-0000-42402 0 $181.30 $181.30 1/15/15 R3425 7021 CHECK JACLIN C. SMITH. AZA FURNACE PC 101-0000-42600 0 $120.85 $120.85 1/15/15 R3425. 7021_ CHECK JACLIN C. SMITH AZA VENT FAN 101-0000-42402 0 $72.54 $72.54 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Printed: Wednesday, January 21, 2015 4:31:14 PM 3 of 6 qwyerWys..m. cF FA, PAID ,' D" VENT FAN PC 101-0000-42600 0' .$28.98 $28.98 1/15/15 'R3425 7021 CHECK JACLIN C. SMITH AZA Total Paid for MECHANICAL: $739.66 $739.66 MULTI -SPECIES 101-0000-20310 0 $1,292.00 $1,292.00 i/i S/15 R3425 7621 CHECK JACLIN C. SMITH AZA UNITS RESIDENTIAL 0-8 1TS Total Paid for MULTI -SPECIES RESIDENTIAL $1,292.00 $1,292.00 NEW CONSTRUCTION, 7— 101-0000-42400 F 0 $667.25 T — $667.25 1/15g5 R3425 7021 CHECK JACLIN C. SMITH AZA. PERMIT. Total Paid for NEW CONSTRUCTION PERMIT: $667.25 $667.25 N NEW CONSTRUCTION 101-0000-42600 0 $1,428.60 $1,428.60 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA PLAN CHECK ALBERS NEW CONSTRUCTION 101-0000-42600 $1,400.00 $1,400.00 10/22/14 R2311 3839 CHECK CONSTRUCTION CO SKH PLAN CHECK .0 INC N EW CONSTRUCTION 101-00 00-42600 -0 $28.60 $28.60 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA PLAN CHECK - Total Paid forNEW CONSTRUCTION PLAN CHECK: $2,857.20, $2,857.20 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA BACKFLOW DEVICE PC 101-0000-42600 0. $4.83 $4.83 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA FIXTURE/TRAP 101-0000-42401 0 $278.07 $278.07 1/15/15 R3425 7021. CHECK JACLIN C. SMITH AZA FIXTURE/TRAP PC 101-0000-42600 0 $278.07 $278.07 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA GAS SYSTEM, S+ 101-0000-42401 0 $36.26 $36.26 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA OUTLETS GAS SYSTEM, S+ 101-0000-42600 0. $24.17 $24.17 1/15/15 R3425- 7021 CHECK JACLIN C. SMITH AZA' OUTLETS PC. WATER HEATER/VENT 161-0000-42401 0 $36.27 $36..27 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Printed: Wednesday, January 21, 2015 4:31:14 PM 4 of 6 CRWYSTEMS BY WATER HEATER/VENT' WATER SYSTEM WATER SYSTEM AZA Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $45.87 $4547 S - _T_0� I 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA ACHE DET D PARENT PROJECTS. ,s 7. 777 REMARKS NO N ON -STRUCTURAL JIM JOHNSON 10/22/2014 11/13/201 . 4 REVISIONS REQUIRED CORRECTIONS 1ST. PLAN CHECK CORRECTION REQUIRED STRUC TO YOUNG DUE STRUC TO YOUNG DUE 11/13 Plans ready for corrections ..11/13 STRUCTURAL JIM JOHNSON 12/29/2014 1/12/2015 1/13/2015 APPROVED APPROVED PLANS APPROVED ARMEN ALTOUNIAN Printed: ' 5of6 - _ CNew`nrew 1ST PW GREEN SHEET AMY YU 1/15/2015 1/22/2015 1/20/2015 REVISIONS REQUIRED EMAILED BILL ALBERS AND ESSI THE COMMENTS ON THE PRECISE GRADING PLAN PRECISE GRADING MYLAR RECEIVED ON 1/20/2015. GREEN SHEET APPROVED WITH THE 2ND PW GREEN AMY YU 1/20/2015 1/28/2015 1/21/2015 APPROVED- CONDITION THAT PAD ELEVATION CERTIFICATE SHEET CONDITIONS AND COMPACTION REPORT ARE REQUIRED PRIOR TO ANY BUILDING INSPECTIONS BOND INFORMATION Attachment T' a CREATED OWNER DESCRIPTION PATHNAIVIE SUBDIR ETRAKIT ENABLED " DOC 10/30/2014 JIM JOH14SON 80-871 VISTA%LAZO.docx 80-871 VISTA LAZO.docx 0 . 'DOC 12/29/2014 STEPHANIE KHATAMI DEBRIS MANAGEMENT - DEBRIS MANAGEMENT - 0 VISTA LAZO.pdf VISTA LAZO.pdf DOC 1/15/2015 STEPHANIE KHATAMI HOA APPROVAL 80871 HOA APPROVAL 80871 0 VISTA LAZO.pdf VISTA LAZO.pdf DOC 1/15/2015 STEPHANIE KHATAMI SCHOOL FEES 80871 SCHOOL FEES 80871 0 VISTA LAZO.pdf VISTA LAZO.pdf DOC 1/15/2015 STEPHANIE KHATAMI ALBERS CONSTRUCTION ALBERS CONSTRUCTION 0 INSURANCE.pdf INSURANCE.pdf DOC 1/15/2015 STEPHANIE KHATAMI ALBERS SCAQMD ALBERS SCAQMDCERTIFICATE.pdf 0 CERTIFICATE.pdf DOC 1/15/2015 STEPHANIE KHATAMI GRANT DEED 80871 GRANT DEED 80871 0 VISTA LAZO.pdf VISTA LAZO.pdf Printed: Wednesday, January 21, 2015 4:31:14 PM 6 of 6 SYSTEMS 871 Building eo_ �,v, V /C Address �'1 / TA Owner Address _Ak&LI N C .SWL IT M zip. 143 PO. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO I_A Z0 LA QUINTA, CALIFORNIA 92253 ContractorLl�iCr�S Cb1aST'Q�c'floN Cc�.iJG, Address .. City Zip Tel. 7 V b . L*_ PulNr..Ik-- q1-2-SI-5 774. .4181 State Lic Lj3 I �g2L"I 2j I' City Sq. Ft & ClassX9 Lic. " Size Arch., En�r., Designer/ STRi1�TS !"NG S 50 SD . OILeA44 be Q- Klwt Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm tha am licensed unde rovisions of Chapter 9 (commencing with Section 7000) of Division oft use s a ssions Cod ,and y 'cens is 'n full jprce nd Effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county w ' quires a permit to construct, alter, improve, demolish, or repair any structure, prior to its iss ce also requires the applicant for such permit to file a signed statement that he is licensed p uant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Sectio 000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a p mit subjects the applicant to a civil penalty of not more than'five hundred dollars (S500). ❑ I, as owner of the proZmnyor my employ s with wages as their sole compensation, will do the work, and the structnot intende r offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contraicense La does not apply to an owner of property who builds or improves thereon and wes such rk himself or through his own employees, provided that such improvements are ended r offered for sale. If, however, the building or improvement is sold within one year ofletio the owner -builder will have the burden ofproving that he did not build or improve for trpo of sale).❑ I, as owner of the propxclusively contracting with licensed contractors to construct the project. (Sec. 7044, Busid Professions Code: The Contractor's License Law does not apply to an owner of property ilds or improves thereon, and who contracts for such projects with a contractors) licensednt to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensa 'on Ins rance, or a F�Ified copy I preo`t. y/S.ec. 38000,, La or Code.) Policy No. 0=' - 'C6mpany 1s1 J Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for o undred dollars ($100) valuation or less). I certify that in the performance of the work for whI911 this permit is issued, I shall not employ any person in any manner so as to become subject orkers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after makin is Certificate of Exemption you should become subject to the Workers' Compensate provisions of the Labor Code, you must forthwith comply with such provisions or this pe it shall be deemed revoked. CONSTRUCTION LENDING AGENC I hereby affirm that there is a constr/ays. ding agency f he performance of the work for which this permit is issued. (Sec. 3097, .) Lender's Name Lender's Address This is a building permit when prod t, signed and validated, and is subject to expiration if work thereunder is suspendays.I certify that I have read this appld state that the above information is correct. I agree to comply with all city and cinances and state laws relating to building construction, and hereby authorize reives of this city to enter the above -mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST. " .00C. GRP. A.P. Number % 7r 2 d ( 0 Legal Description L.n t' 10 ' Wart- 7,034 Project Description I L91 t7 u GvyeQ-e-b L.c5g I (A C U„d-r VW -N!� A-c.) No No. w. J No. QX ( &QErUnits 1 New ❑ Add Nery Repair ❑ Demolition ❑ i-/ Estimated Valuation 1 t Moot 0& PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. ' Grading Driveway Enc. t Infrastructure TOTAL (� CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line — Rear Setback from Rear Prop. Line _ Side Street Setback from Center Line Side Setback from Property Line — FINAL DATE INSPECTOR Issued by: — Validated by: Date WHITE = BUILDING DEPARTMENT Validation: YELLOW = APPLICANT PINK = FINANCE tea. • Coachella Valley Unified School District This Box For District Use only 83-733 Avenue 55, Thermal, ICA 92274 ' DEVELOPER FEES PAID (760) 398-5909 — Fax, (760) 398-1224 AREA: - AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT:" CHECK #: ' INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Named JaclinSmirt�h Date: January 14, 2015 Owner's Name: Phone No. " Project Address: 80-871 Vista Lazo, La Quinta; CA 92253 Project Description: Single Family Dwelling Unit APN: ' 762-250-010 Tract #: Lot #'s: Type of Development: Residential , XX Commercial Industrial Total Square Feet of Building Area: 5;092 Sq. Ft. Certification of Applicant/Owners:' The person signing certifies that the above iriformationis correct -and makes this statement under penalty of pequry and further represents that he/she is authorized to sign on behalf of the owner/developer.. 1 / . Dated: 1 Signature: SCHOOL DISTRICT'S°REQUIREMENTS FOR THE ABOVE PROJECT'HAVE BEEN OR WILL BE SATISFIED -IN ACCORDANCE WITH ONE OF THE FOLLOWING:' (CIRCLE ONE) Education Code Gov. Code Project: Agreement Existing .:.. Not Subject to Fee 17620 65995 ' Approval Prior to 1/1/87 Requirement Number of Sq.Ft. .5,092 Sq. Ft.: ' Amount per Sq.Ft. $ 3.36 Amount Collected $ 17,100.12. Building Permit Application Completed: Yes/No By:. Elsa F. Esqueda,.Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF F D TAT ME OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that th't515istrict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions("Fees"), of the 90-day period to protest the imposition of these. Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees'or the validity thereof, commences with the payment of the fees or performance•of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in. part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions. may be granted. iN4V:c/Inydoes/devlecs/certificate ofcompliance firm updated 3-2007 11/2010 Page 1 'of 5 Doc TTax Paid Recorded in Official Records + RECORDMiti REQUESTED BY: County of Riverside Orange Coast Title Co. Larry W. Ward 1 Assessor, County Clerk & Recorder AND WHEN RECORDED tIAA1L TO: isclin C. Smith . t 1302 E. Wedgewood Ave. * —This document was electronically submitted Spokane, WA 99208 to the County of Riverside for recording" Receipted by: AGONZALEZ r nro ar•AW: I -UK KtWK0tK'5 USE ONLY: Title Order No.: 1661►7W 10 n Escrow No.: 041162-OL GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX Is $220.00 [XI computed on full value of property conveyed, or „ [ I computed on full value less value of liens or encumbrances remaining at time of sale. I I Unincorporated area [XI City of La Quints AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Watson David Todd Bortftwlck and Kathryn Joyce Borthwick, Husband and Wife hereby GRANT(s) to: Jaelln C. Smith , a single woman ' , the real property in the City of La Quints, County of Riverside, State of California, described as: Lot 10 of Tract No. 28034, in the City of La Quinta, County of Riverside, State of California, according to Map recorded in Book 258, Pages 69 and 70 of inclusive of Maps, in the Offico of the County Recorder of California. Also Known as: Vacant Land APN 762-250-010-1, La Quints, CA 92253 AP#: 762-250-010-1 DATED April 22, 2014 STATE OF Washington ti CZL nz j COUNTY OFOn atson David Todd Borthwick before me, r [ C wY• V� A Notary Public personally appeared, --- Watson David Todd Borthwick and _ thryn ce ck .. , Kathryn Joyce Bortmick who proved to me on the basis of satisfactory s ev�nce to be the person(s) whose nsme(s) Islam subscribed to the within instrument and acknowledged to me that he/shetthey 1 . executed the some. in hisrherAheir authorized cspactty(iea), and that by his&wAheir signatura(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. „ I certify under PENALTY OF PERJURY under tha laws of the state of Caftmis that the foregoing paragraph Is bw end corrwA. �i. r, WITNESS my hand and ofriclal sagl. t , Signature "(Seal) MAIL T STA E O PARTY HOWN BELOW; IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE: RIVERSIDE,CA - Document: DD 2014.170015 Branch :OCC,User :3600 Comment: ; Station Id :SOL'I ,s • A DOC #2014-0170015 Page 3 of 5 05/09/2014 08:00 AM ACKNOWLEDGMENT , STATE OF WASHINGTON COUNTY OF WHATCOM 4 . P. I certify that I know or have satisfactory evidence that t r t) A- u 0 f.).rt�.u�ck et, 3 Ware the person(s) who appeared before me and that said person(s) acknowledged that shetlWthey signed this instrument and acknowledged it to be he4ltis/their free and voluntary act for the uses and purposes mentioned in the instrument. Givenunder my hand and seal of office this j day of C l •iit , 2014. Laura Lesley Vestanen, Notary Public Notary Public Residing at Point Roberts, WA State of Washington Commission number 95291 z LAURA LESLEY VESTANEN ' My Commission Expires: 10 August 2015 My Commission Expires August 10, 2015 Description of attached ddocument t. Title t Document date Number of pages Comments RIVERSIDE,CA Page 3 of 5 . ` ' 'Printed on 11/3/2014 3:57:19 PM Document: DD 2014.170015 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009. Green Sheet approvals are forwarded to the Buildina & Safety Department directiv by Public Works. Please DO NOT submit the Green. Sheet (Public Works Clearance) Packet to the 'Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant.. Date: /�� !S Developer: Omsi-a-lo VT k013 Cy 141-C. Tract No.: 2034 Tract Name: L1,,rvg GkT-M Lot No.(s) 10 Address(s): ytsrk LA -to Phone Number: OW ) %7 q ` k7 A% The following are the requirements for Public Works Clearance to authorize issuance of a building permit: from the Building & Safety Department: ❑ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 &.#7 BELOW ❑ WALLS, .SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with .the approved design elevation for _ building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading'plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification.number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: Date: Public Works Distribution: ( Green Sheet to Building & Safety "A/771_ Pf1'U f_E?2r 47VI,? ( ) Green Sheet to Planning Department Ga^04 70ti 1�7�. Declined for approval for reason(s) as follow(s), please correct and resubmit: I TAChecklists - For s & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10-02-12.doc City of La Quinta - PM 10 Fugitive Dust Control Project Information Construction Phase PM 10 Agreement (< 1 acre/Int or Infill Prniectl Project Information Project Contractor: ALP,u_;'i . Co*)s il-u er wv-� �'� G Project Phase (check one) Construction 0 Demolition Project Name: - fAIA l m Qmyt 11 �2A_-St D L--U C .— Project Tract/Lot Numbers: ' AZT Z�'0 3�( t Lo Tr- t 0 . Project Street Address: 80 1,ik LA- Du #NTk- CA- S3 Anticipated Start Date:/ / Anticipated Completion DateJfi� : Total Acres in Active Construction (< 1 acre per Lot): S 0 '� j r PM10 Contact Information . Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: Title: f it S% as V_ {' Company Name: A `\n�e_YS `C)vJS'j0-VCrLvkZJ CQ Mailing Address: Pip 23 8 City, State, ZIP Code: L.d�(D v I l ZZ�I Primary Phone #: t kao - -r) ri Li - O Fax #: 24 Hour Emergency Phone#: C G (DU Cell Phone #: Email Address: b a A IVws O PM 10 Certificate #: �v S—0 D 1 (O 3 I ^ I 1 11 The above stated nronerty owner (or authnri7Pd rP.nrP.SP.ntgfivP.1' Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; :• Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. Acknowledges that dust control is required twenty-four. (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in ,continuous compliance with all requirements of the approved dust control plan; Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary-, Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or an City/County initiated) abatement activities. Signature of P operty Owner or Authorized Representative Date Y ~ 'e);,,..-'_.•'� �. `�-. ,,,`��, ^l7 :-r `C. s.�,,- ���.,' _ y[���� ,' J�`-vim �ca�t.- .{`+� • - a �,. ��. ,� �: • V �I .It.,,.�'. .%�.�'�.t �+' �t'.•1.4-y�,('C t�...,C. �"`.t ..,✓.�.^..-.'77Y[[ rf 1� �r -;n ( �::. t'i t•� � � �ti. �{ { ��. 1 '1 Y` , � I_-�* `� l �\N. �. f�( ^,I._'•• ai` ' ��c.. � ': ,a.'� •y "• 4� ,� i.i '- ,y I �:- Y k�� l!"�r�.. Jar �. J''+•i�-3��� '2%��.�+:'i7R� �3". `�', .�.t,{��., ;�,�j `'i �.�- � \�`f � `�'.r�i:r��J 'V.`• - r South Coast Air Quality Management District . t - acknomledges by thi or AV Ay,. •fi ' '. .,vYmj • .. 4 �r ! • that r Bill Albers t successfully completed , _ •�y 5� - C;OA-CH�ELL�1 Yiw- �Y FUCaTIVE BUST CONTI�,OL CLASS p ? 01/15/2015 ezaAf Date Issued: j� (Eapirer 2yearrJrom date of irrf+ante), Training Officer Engineering and Compliance ru CV1501-001632-1717 w '; � � ���(,�t%Z~t�L�:aI"�,�,'1 �vC.ij`�,r.�,'�- `Cj� .� �F.` t T',...:1 i� 4:`�t/� �3t�'�%-'� �;6.''C�'�.�t'.�1a rf r��. 1�'<<P..'v.i �`-"�,:!r�`\��•,�`l� .�'!'r�i `„+'gin, a�fi�'� .'r �-^-.,p-«..«-.vn^orr.�.:�.n.aw•. ,�. '[,-�;: � -. - - - -. _ -- .. -. ,.'`�dwFfaw"$..a,-�-ms4.-.--ax'.^^4�*'�ve'�.+�4^�. Plan Submittal Building Permit Number. . Project Description: SFR Demo Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan 12/17/2014 Job Site Address] 60871 Vista Lazo Owner's N1 Number, Street, or PO City. State, Postal C Owners Phone Nun Owners E-MaU Add Jaclin Smith 106 Jaciln Way Sandpoint, ID. 83864 50"94-4135 Project-Manage's Name B1II Albers Project Managers Phone Number 760-774-8787 Project Menagers E-mail Address b.albersO.eaRhlink.net Builder / Contm Number, Street or PO City, State, Postal C Albers" Construction Co. Inc. po� . - 4ox 238 gZ24�- Project Square Footegel aipprox. 5,904 sq ft City Approval.By Date of City Approval To Be Discardei Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated 1 Reuse• *Describe Items Recycle Trash 43.5 . 24.0 0' .O 3n 3 � _z o m n T rM C .z 3D rn z —f ble Product Tons Masonry (broken)ff6.25 -PlasterScrap MetalTile (floor). Tile (root) 0.75 Wood Landscape Debris_ 0.00 Diversion: 84.44% I understand it is the property ownses responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. t hereby certitythat completion, implementation and adherence of the Debris Management Plan'(DMP) for the above named project shall guarantee thatat least 50% of the jobstte waste is diverted from landfiliing. The remaining material will be recycled or mused. I will divert, for -recycling or reuse, remaining materials generated from the first day of the project through the compledon.otthe project In accordance with this pion. This DMP is issued in the name of the propertyowner(s) and shall remain their property throughout the construction andlor demolition project. A contractor serving as egent.of the owner may obtain a DMP for the owner. However, the DMP Is still 'Issued in the name of the property owiier(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bbmonthly reports. If self -hauling, all refuse.material from this project site must be taken to an approved recycler or transfer . wQ+. �� Crrid vu l(0 e. j�. Date / 231`Y . . - Owner / Developer I Project Manager uperinienNnt YOUNG r A ENGINEERING ' . -. ram°°'� .. ' , �%` €.� - E • { Letter of Transmittal To: City of La Quinta _-.Today's Date: 1-12-15 ' 78-495 Calle Tampico City Due Date: 1-12-15 . La Quinta, CA 92253 ,, x ' Project Address: 80-871 Vista Lazo Attn: Kay Plan Check #: BRES 2014-1143 _ Submittal:. ❑ `ist' s ❑. '. 4th . J E 3'd ❑ ' Other: -We are forwarding: �® By Messenger,- ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: " `" - r Includes: `. ' # Of Descriptions: r.. Copies:.Copies: . ' '_ ❑ Structural Plans : �' • ' ? ®' 1 Revised Structural Plans . .1 Structural Calculations , ,��•r'' ❑ Revised Struct. Calcs . Truss Calculations Floor ❑ Revised Truss and Roof v3 Report ® Soils _ p ❑ Revised Soils Report Structural Comment List/ 3 ® 7 3' Approved Structural, Plans ' _ Responses - ® 1'. Redlined Structural Plans ❑ ' • Approved Structural Calcs ❑ - Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑.. " Approved Soils Report - °`❑ Redlined Soils Reports y ❑ , Mt, er• Comments: Structural content is approvable. If you have any questions, please call. CITY OF _ . Time = 2.25 HR BlEVELOPIvii 1 This Material Sent 'for'. ❑ Your Files ,� ' ' i _ ®. ` Per Your Request ❑ 'Your Review ` " , ' ❑ Approval ❑ Checking ` �' ❑ At the request of: r Other: ❑ . . :By: Kathryn Samuels ,... -Palm Desert Office: ® (760) 772-5107 ' Other :.❑ , t� + 1� BUILDING ENERGY ANALYSIS REPORT ' PROJECT: - - Jaclin , C. Smith Residence , # _ ;Lions Gates #10 ; * La. Quinta, CA 92253 .Project Designer: . Stracts Architects .� 550 S. Oleander Palm Springs, CA92262.. ", (760) 636-8951 ' CITY OF LA QUINTA ' Report. Prepared by:: BUILDING & SAFETY DEPT. »'• Jon Scott APPRO ED FOR CONSTR CTION Tll` Scott Design and Title 24, In . 77-085 Michigan Drive s DATE .. Palm Desert, CA 9221.1 (760) 200-4180 Job Number: Date: ' 12/4/2014 • The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential'2013 Building Energy Efficiency Standards. s� t This program developed by EnergySoft, LLC — www.energysoft.com. Ene Pro'6.3 by EnergySoft User Number 6712: )D: ' x CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tation OD Project Name: Jaclin C. Smith Residence Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith -Res -Lions Gate-STRACTS-14.xml CFOF-01 Page 1 of 12 GENERAL INFORMATION 01 - Project Name Jadin C. Smith Residence 02 Calculation Description Title 24 Analysis 03 Project Location Lions Gates #10 04 A City La Quinta 05 Standards Version Compliance 2015 06 Zip code 92253 07 " Compliance Manager Version SEMCmpMgr 2013-3 (651) . 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 .10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 120 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 - Total Cond. Floor Area (FTZ) 5092 15 .8� Number of Zones 4 16 Slab Area (FTZ) 5092 Number of Stories 1 18 Addition Cond... Floor Area N/A 0^9'� Natural Gas Available Yes 20 Addition Slab Area (FTZ) N/A a�2�1 Glazing Percentage (%) 18.8% COMPLIANCE RESULTS ' 01 Building Complies with Computer Performance Aft.� 02 This building incorporates features that require field testing am verification by a certified HERS rater under the supervision of a CEC-approved HERS provided 03 This building incorporates one or more Special Features shop"tbelow ENERGY USE SUMMARY 04 05�. 06 07 08 -�'Energy r Use (kTDV�/ft)C) Standand 6Design Proposed Design Compliance Margin. Percent Improvement l m Space Heatin 4.84 4.83 0.01 0.2% .' !k a6e Cooling . �10P 126.12 124.99 1.1-3 0.9% I IAQ� V,entila`tio`n� I �1.30 1.30 0.00 0.0% I Wier. eavhg� 5.04 5.62 -0.58 -11.5% PhoroGoJta1,c` ffs — 0.00 0.00 — �mplia-ReEner y T6tl o et.A 137.30 136.74 0.56 0.4% z®� Registration N Registration Date/Time: CA Building Energy Efficiency Stand5r'ds - 2013 Residential Compliance Report Version - CF1R-16172014-651 HERS Provider: Report Generated at: 2014-12-04 14:45:23 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE.� OD . Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04; 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml REQUIRED SPECIAL FEATURES The following are.features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins CFF-01' Page 2 of 12 HERS FEATURE SUMMARY The following is a summary of the features that'must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications:. • IAQ mechanical ventilation Cooling System Verifications: • Verified EER . Verified SEER • Refrigerant Charge V. • Fan Efficacy Watts/CFM HVAC Distribution System Verifications. °® • -Duct Sealing Domestic Hot Water System Verifications: — None — ,. ENERGY DESIGN RATING 4L%�. - This is the sum of the annual TDV energy consumption for energy use components includ5, in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy UW Energy Desrgn Ratrng 'd Margin . Percent Improvement Total Energy. (kTDV/f2p 174.32 �N� y ' ` 173 76 0.56 0.3% includes calculated Appliances and Miscellaneous Energy Use (AMEU) A BUILDING ! FEATURES INFORM71TiOfl �01 T 02 t� 0 04 05 06 07 0;01 Pr j pt Named L ;Coed tioned Floor Area (Oft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Jaclin C. rMh Resi en&eJ -' l 5092 VJ 1 12 4 .4 2 Liciency m nomRegistration N.Registration Date/Time: CA Building Entandards 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-12-04 14:45:23 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF19RF-01 Page 3 of 12 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Bedroom Conditioned HVAC 1 masterl 871 14 DHW Sys 1 Kitchen Dining Conditioned HVAC 2 kit2 864 14 DHW Sys 1 Greatroom & Hall Conditioned HVAC 3 & 4 great3 2245 14 DHW Sys 1 Bedroom 2,3 & 4 Conditioned HVAC 5 bed4 1112 14 DHW Sys 1 OPAQUE SURFACES - 01 02 03 �� 04 05 06 07 08 Name Zone Construction � Azimuth .Orientation Gross Area (ftZ) Window Area (ft) Tilt deg) 30d Wall Master Bedroom R-21 Wall (W21.2x6.1,6)j� 30 Right 378 40 90 120d Wall Master Bedroom R-21 Wall (W.21.24 16),Y 120 Front 378 0 90 210d Wall Master Bedroom R-21 Wall (W.21..2z6.16) 210 Left 1210 57.9 90 300d Wall Master Bedroom R-21 Wall (W.2i':Fx6A6) 300 Back 672 46 90 Roof Master Bedroom R-38 R of Attic 871 30d Wall 2 Kitchen Dining R-21 Walh(W21.2x6.16) 30 Right 462 102.4 90 300d Wall 2 Kitchen Dining R-21gWall (W.21.24.16) 300 Back 462 76 90 Roof 2 Kitchen Dining SR-38 Roof Attic A. 864 30d Wall 3 Greatroom. & Hall - 21 Wall (W21.24.16) 30 Right 210 13 90 E Wall Greatroom & Hall ®`FR-21 Wall (W21.2x6.16) 90 specify - 210 13 90 120d Wall 2 Greatroom & Hall R-21 Wall (W.21.24.16) 120 Front 1650 183 90 Nall UJ Greatroom & Half" R-21 Wall (W.21.2x6.16) 180 specify - 378 0 90 10d�Nall 2 rn Greatroom & Hall � R-21 Wall (W21.2x6.16) 210 Left 210 25 . 90 W Wall O C_ Greatroom & Hale R-21 Wall (W21.2x6.16) 270 - specify - 210 18 . 90 3 0 Wall 3 ® 1 Greatroom & Hall)' R-21 Wall (W.21.24.16) 300 Back 924 222 .90 oof3 Greatroom.&KHall Va.. R-38 Roof Attic 2245 3 d all 4 (n Bedroogi!G�3 & 4 R-21 Wall (W21.24.16) 30 Right 1386 66 90 12 d k3pil 3 :13 Beds 0 2,3 & 4 R-21 Wall (W.21.24.16) 120 Front 525 45.9 90 210 Wall 3 Bloom 2,3 & 4 R-21 Wall (W.21.2x6.16) 210 Left 627 50 90 no Wall 4 Bedroom 2,3 & 4 R-21 Wall (W.21.24.16) 300 Back 672 0 90 R o 4 (fl Bedroom 2,3 & 4 R-38 Roof Attic 1112 v®� Registration Nurrijbe : CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS.Provider: Report Generated at: 2014-12-04 14:45:23 CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE, COMPLIANCE OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14,42, Thu, Dec 04,2014 Calculation Description: Title 24 Analysis . Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF F-01 Page 4of12 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 No No CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF•RF-01 Page 5 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading NEW Window 30d Wall (Right-30) - - 1 40.0 0.28 0.28 Insect Screen (default) NEW 2 Window 210d Wall (Left-210) - - 1 4.0 0.28 0.28 Insect Screen (default) NEW 3 Window 210d Wall (Left-210) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 4 Window 210d Wall (Left-210) - - 1 3.9 0.28 0.28 Insect Screen (default) NEW 5 Window 210d Wall (Left-210) - < A - 1 6.0 0.28 0.28 Insect Screen (default) NEW 6 Window 210d Wall (Left-210) - - 1 7.5 0.28 0.28 Insect Screen (default) NEW 7 Window 210d Wall (Left-210) - 1 12.5 0.28 0.28 Insect Screen (default) NEW 8 Window 210d Wall (Left-210) o r - 1 6.0 0.28 0.28 Insect Screen (default) NEW 9 Window 210d Wall (Left-210)®�- -- 1 6.0 0.28 0.28 Insect Screen (default) NEW 10 Window 210d Wall (Left-210) "�' - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 11 Window 300d Wall (Back-300) `� - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 12 Window 300d Wall (Back-300) ®` - - 1 40.0 0.28 0.28 Insect Screen (default) NEW 13 Window 30d Wall 2 (Right-30) - - 1 102.4 0.28 0.28 Insect Screen (default) NEW 14 Window 300d Wall 2 (Back-300) s�� -- -- 1 76.0 0.28 0.28 Insect Screen (default) NEW 15 Window 30d Wall 3 (Right-30) - -- 1 13.0 0.28 0.28 Insect Screen (default) NEW 16 Window E Wall (- specify-90)•y' - - 1 13.0 0.28 0.28 Insect Screen (default) NEW 17 Window 120d Wall 2 (FronYl�120) - - 1 11.0 0.28 0.28 Insect Screen (default) NEW 18 Window 120d Wall 2 (R6nnt=120) - - 1 11.0 0.28 0.28 Insect Screen (default) NEW 19 _ �Wirado 120d Wall 2k( ront-120) - - 1 11.0 0.28 0.28 Insect Screen (default) NEW 20 Window0J 120d Wal�lr2:(Front-120) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 21 ER 11AIrLdow r 120d(Wall 2 (Front-120) - -- 1 25.0 0.28 0.28 Insect Screen (default) NEW 22 Q nd6w 120iiyWall 2 (Front-120) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 23 W cow n. 12ed Wall 2 (Front-120) - - 1 13.0 0.28 0.28 Insect Screen (default) NEW 24 V�nd# go W20d Wall 2 (Front-120) -- - 1 13.0 0.28 0.28 Insect Screen (default) NEW 25 V�(OJ°'' U) ��V 120d Wall 2 (Front-120) - - 1 13.0 0.28 0.28 Insect Screen (default) NEW 26 ::r 120d Wall 2 (Front-120) - - 1 13.0 0.28 0.28 Insect Screen (default) NEW 27 Wi - ow 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 28 VV 120d Wall 2 (Front-120) -- - 1 6.0 0.28 0.28 Insect Screen (default) NEW 29 Win • w 120d Wall 2 (Front-120) - - 1 6.0 1 0.28 0.28 Insect Screen (default) 74 Registration Number: I •��r Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:45:23 CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF*F-01 Page 6of12 NEW 30 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 31 Window 120d Wall 2 (Front-120) -- - 1 6.0 0.28 0.28 Insect Screen (default) NEW 32 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 33 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 34 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28. 0.28 Insect Screen (default) NEW 35 Window 210d Wall 2 (Left-210) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 36 Window 210d Wall 2 (Left-210) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 37 _ Window W Wall (- specify -270) - - 1 18.0 0.28 0.28 Insect Screen (default) NEW 38 Window .300d Wall 3 (Back-300) 24.0 # 8.0 1 192.0 0.28 0.28 Insect Screen (default) NEW 39 Window. 300d Wall 3 (Back-300) -+�' - 1 30.0 0.28 0.28 Insect Screen (default) NEW 40 Window 30d Wall 4 (Right-30) 1 6.0 0.28 0.28 Insect Screen (default) NEW 41 Window 30d Wall 4 (Right-30) - 1 30.0 0.28 0.28 Insect Screen (default) NEW 42 - Window 30d Wall 4 (Right-30) - - 1 .6.0. 0.28 0.28 Insect Screen (default) NEW 43 Window 30d Wall 4 (Right-30) �� d - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 44 Window 30d Wall 4 (Right-30) � - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 45 Window 30d Wall 4 (Right-30) ®� - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 46 Window 30d Wall 4 (Right-30) `` - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 47 Window 120d Wall 3 (Front-120) •®� - - 1 3.9 0.28 0.28 Insect Screen (default) NEW 48 Window 120d Wall 3 (Front-120)0 - - 1 42.0 0.28. 0.28 Insect Screen (default) NEW 49 Window 210d Wall 3 (Left-21�0).# - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 50 Window 210d Wall 3 (Leftj2j1;0) - - 1 25.0 0.28 0.28 Insect Screen (default) NEW 51 Window 210d Wall 3 (�♦j?210) - - 1 12.5 0.28 0.28 Insect Screen (default) s� i A11% DOORS t7 ` / -i 041� � --` �' " 02 03 04 I Na ie�� � Side of Building Area (ft) U-factor Do�0 S Wall 20.1 0.50 OVERHANGS AND fl �S Cif (n �� 01 03 T1 0 •t 03 04 05 06 07 08 09 10 11 12 13 1 14 x.✓� `� Overhang Left Fin Right Fin Left Right Windo e61 Dist Up Extent Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up NEW 3 r4 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: I Registration Date/Time: CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-12-0414:45:23 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CFF OR Page 7of12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers 2x4 Top Chord of Cavity/Frame: no insul. /2x4 Top Chrd Roof Truss @ 24 in. Roof Deck: Wood Siding/sheathing/decking ' Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in: O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O., GG?� R 21 Exterior Finish: Wood Siding/sheathing/decking hk� SLAB FLOORS 01 02 03 04 05 06 07 Name Zone, Area (ft2) � Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab Master Bedroom 871-*v 109 None 0.8 No Covered Slab 2 Kitchen Dining 8" 44 None, 0.8 No Covered Slab 3 Greatroom & Hall e�&.245 170 None 0.8 No Covered Slab 4 Bedroom 2,3 & 4 �•�'1112 151 None 0.8 No BUILDING ENVELOPE.- HERS VERIFICATION t�m01 - 02 03 04 Quality I`n'sulation Installatiort ydilI Quality Installlaiion of Spray Foam Insulation Building. Envelope Air Leakage . ACH @ 50 Pa m Not Required I- 7 r, v Not Required Not Required a tl -n � s 1 17 . WATER HEATING SYSTEM!r) ' -5 V ` '. . -7 A. 1 7 - 90 ' 02 A 03 04 05 06 N System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW y 1 7� D� Pipe Insulation, All Lines DHW Heater 1 1 .0% DHW ty 1 C . rT i [)�IMI Pipe Insulation, All Lines DHW Heater 1 2 .0% z®��® Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 HERS Provider: Report Generated at: 2014-12-04 14:45:23 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF*F-01 Page 8of12 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01" 02 03 b,04 " 05 06 07 Name Pipe Insulation Parallel Piping " Compact Distribution Point -of Use Recirculation" Control Central DHW Distribution DHW Sys 1 - 1/1 v N/A N/A N/A N/A N/A N/A DHW Sys.1 - 1/2 N/A N/A s N/A - N/A N/A N/A HVAC SYSTEMS 4w ' 01 02 03 �.. 04 05 06 07 Heating Systgii Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC 1 masterl Other Heat/Cool Heating Component 1 Yes Cooling Component,1 Yes Air Distribution System T' 871 HVAC 2 kit2 Other Heat/Cool. ftz Heating Component 2 Yes Cooling Component 2 :Yes Air Distribution 864 System 2 HVAC 3 & 4 great3 tier eat/Cool ' Heati gq Component 3.. �K Yes Cooling Component 3 Yes Air Distribution ' System 3 2245 HVAC 3 & 4, re43 COther. Heat/Cool v Hteating Component 3 Yes Cooling Component 3 Yes Air Distribution System 3 2245 ` w I HVAC 5 b d4 � ther H Heating Component 4 Yes Cooling Component 4 Yes Air Distribution 1112 �q at/Cool System 4 I O u 90 -- � ) ) c:: <rn- -� rn o® � z � Registration Number: ���O Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-10172014-651 HERS Provider: Report Generated at: 2014-12-04 14:45:23 CERTIF,JOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF*F-01. Page 9 of 12 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 3 CntriFurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 CntdFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS. 01 02 03 04 05 06 07 Efficiency 00 Multi -speed Name System Type EER Zonally Controlled Compressor HERS Verification �4SEER Cooling Component 1 SplitAirCond - Split air conditioning 13 ��e 16 No No Cooling Component system �� 1-hers-cool Cooling Component 2 SplitAirCond - Split air conditioning 13 > 16 No No Cooling Component system 2-hers-cool Cooling Component 3 SplitAirCond - Split air conditioning 13 p 16 No No - Cooling Component system 3-hers-cool Cooling Component 4 SplitAirCond - Split air conditioning , �® T13 ® 16 F No No Cooling Component system - I 4-hers-cool 1_ HVAC COOLING - HERS VERIFICATION 01 02 �a 03 04 05 06 a Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Comp n¢rtt 1-hers71q of = Required ��` 350 Required Required Required Cooling Comp n nt-2-her o, C = Required 350 Required Required Required Cooling Comp n t 3-herCpo NO 1;,,) Required 350 Required Required Required Cooling Comp e t 4 hers= o go t I Required' 350 Required Required Required Registration Number: �� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - U1R-10172014-651 HERS Provider: Report Generated at: 2014-12-0414:45:23 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Jaclin C. Smith Residence Calculation Date/Time:.14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF*F-01 Page 10 of 12 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System .1 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution ; System 1-hers-list Air Distribution System 2 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 2-hers-list Air Distribution System 3 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 3-hers-dist � _ Air Distribution Air Distribution System 4 Ducts located •in attic Sealed and tested -8 Attic . �� Attic None System, 4-hers-dist HVAC DISTRIBUTION- HERS VERIFICATION ®®`� 01 02 03` 04 05 06 07 Duct Leakage r Verified Duct Design Low -leakage • �� Name - Verification Duct Leakage Target (0 Verified Duct Location Return Supply Air Handler Air Distribution System Required q 6.0 Not Required Not Required Not Required — 1-hers-dist Air Distribution System Required' 66-0 Not Required Not Required Not Required — 2-hers-dist ^ Air Distribution System. 3-hers-dist Required 6.0 Not Required ` Not Required Not Required — A'1D, Air Distribution System Required �`a 6.0 Not Required Not Required_ Not Required — 4-hers-dist �® I n w.r I ► ALr - HVAC. FANJ SfFSTEMST ~ C7 02 03 04 N �Ie U Type Fan Power (Watts/CFM) HERS Verification �� I HVAC{Ean t &A W Single Speed PSC Furnace Fan 0.58 HVAC fan 1-hers-fan HVAC_jjF�n (J3 �a Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan WHVAC Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC s Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan =ml!llftl HVAC FAN SY EIMS - H R iC T'10 --* 01 02 03 s Registration Numu'.� Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-0414:45:23 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04,.2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.icml CF F-01 Page 11 of 12 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 0.58 HVAC Fan 4-hers-fan Required 0.58 . IAQ (Indoor Air Quality) FANS 01 02 03 04 06 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 148.42 0.26 Default 0 Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 v 0.52459 1 WH Fan 2 61 0.52459 1 WH Fan 3 61 ��� 0:52459 1 WH Fan 4 61 `®� 0.52459. 1 40> rn -Lr,- CA-- °®® Registrati- on Date/Time:Registration Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651. HERS Provider: - Report Generated at: 2014-12-0414:45:23 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:42, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml . CF, F-01 Page 12'of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I. certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signatur Jon d. SCott Jon Scott Company: Signature Date: - Scott Design and Title 24, Inc, 12/4/2014 Address: CE:A/HERS Certification Identification (If applicable): 77-085 Michigan Drive City/Stat ip: "Falm Desert,' CA 92211' Phone: (460) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT' I certify the following under penalty of perjury, under the laws of the State of California: o�� 1. 1 am eligible under Division 3'of the Business and Professions Code to accept responsibility forithe building design identified on this Certificate of Compliance. 2., 1 certify that the energy features.and performance specifications identified on this Certificate 'Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. .or 3. The building design features system design features identifed on this Certificate of.Comp ance are consistent vvith'the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencyWor approval with this building permit application. Responsible Designer Name: �. Responsible Designer Signature: Stracts Architects •A� ` Company: v Date Signed: Stracts Architects �1 Address: �� License:, 550 S. Oleander®®. City/State/Zip: r� -- Phone: Palm Sp7ings, CA 9276 '7 ,�� . .(760) 636-8951 90, QM o®o Registration Numb Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-12-04 14:45:23 • E • RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Jaclin C. Smith Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 121412014 Project Address Lions Gates #10 . La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area' 5,092 Addition n/a # of Units 1 . INSULATION Construction Type Area Cavity ft) Special Features Status Roof Wood Framed Attic R 38 5,092 New Wall Wood Framed R 21 9,586 New Slab Unheated Slab -on -Grade - no insulation 5,092 Perim = 474' New Demising Wood Framed R 13 2,479 New Door Opaque Door no insulation 20 New FENESTRATION Orientation Area ft2 I Total Area: 958 Glazing Percentage: 18.8 % U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.28 Exterior Shades Status Right (NE) 221.4 0.280 0.28 none none Bug Screen New Left (S1M 132.9 0.280 0.28 none none Bug Screen New Rear (NKq 152.0 0.280 0.28 none none Bug Screen New Front (E) 13.0 0180 0.28 none none Bug Screen New Front (SE) 228.9 0.280 0.28 none none Bug Screen New Rear (1/10 18.0 0.280 0.28 none none Bug Screen New Rear (NVI9 192.0 0.280 0.28 18.0 none Bug Screen New HVAC SYSTEMS Qty.. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC 1 master Ducted HVAC 2 kit Ducted Ducted Attic Ducted Attic.1Ty C). w HVAC 3 & 4 great Ducted Ducted Attic Q1 JILDINGO& S ew WATER HEATING Qty. Type APPRoVED Gallons Min. Eff Distributio CONSTRU(*-Quh 2 Small Storage Gas 50 0.66 All Pipes Ins New BY EnemvPro 6.3 by EnemySoft User Number 6712 Run Code: 2014-12-04T14:46:01 ID: Page 15 of 39 • • • RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Jaclin C. Smith Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 121412014 Project Address Lions Gates #10 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,092 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ftz Special Features Status FENESTRATION Orientation Area ft2 Total Area: ng Percentage: 18•8 % New/Altered Average U-Factor: 0.28 U-Fac SHGC' Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC 5 bed Ducted Ducted AtticC)I/veWTA o ^ T. �V WATER HEATING Qty. Type °° Gallons Min. Eff, Distribution FOR CONSTRU�1,aOtus 0 DATE _-- -- EnemvPro 6.3 by EnemySoft User Number: 6712 Runcode: 2014-12-04T14.46:01 ID: Page 16 of 39 4 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date Jaclin C. Smith Residence 121412014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 110.6 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF-1 R Form. " 150.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U-factor. 150.0 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U-factor. * 150.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U-factor. 150.0 : Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U-factor of 0.58. 2. The weighted average U-factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)l: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U-factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section .110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0 h : Heating and/or cooling loads are calculated in accordance with ASHRAE SMAGNA-e 150.0 i : Heating systems are equipped with thermostats that meet the setback re u en(eis�SON TAcQU 1 V TA §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than tie wrapped with insulation havinq an installed thermal resistance of R-12 or greater. _ _ r- §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating s7 ter4-, Q h in`dir._ . hot wat r tanks have R-12 external insulation or R-16 internal insulation where the internal insulation Rlvel ire ivii�iq�cUhTJor of t tank. DATE BY - EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 17 of 39 110.4 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cov §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a t programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, pipin Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for co with TABLE 150.0-A or TABLE 150.0-B as applicable. §150.0(k)1 C: The wattage of permanently installed luminaires shall be determined as so MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Jaclin C. Smith Residence 1121412014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.0Q)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)7: Exhaust fan systems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all: the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heatinn. r. met SNuitft1� dll9llaSWAVE1716et filters, w I � n 50.0 . FOR CONSTRUCTION pliance with Section 150.0(k) in accordancE AWS §150.0(k)1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic an5 shall ave an output frequency — 20 kHz §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page 18 of 39 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Jaclin C. Smith Residence 121412014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150.0 k . 150.0 k 2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a, manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; . meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eigkt+eFFRGF-ve4qjeles-peFsall complV with the applicable requirements in Sections 110.9 130.0 130.2 130.4, 140.7 and 141 0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not conta ocke rra�y u a screw-b WWI ��P no more than five watts of power as determined accordingto 1 30.0d . BUILD�I�I� & S�i-t� §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply the /s PROVED. with applicable requirements for nonresidential garages in Sections 11 .9, 13 0 30 130.4, 140.6, and 141.0. FOR CONSTRUCTION §150.0(k)12A. Ina low-rise multi -family residential building where the total interior common areLin single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that builshall be high efficacy luminaires or controlled by an occupant sensor. TE BY §150.0(k)12B. In a low-rise multi -family residential building where the total interior common are 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and a ress. EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page 19 of 39 4 4 .HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name actin C. Smith Residence Date 12/4/2014 System Name HVAC 1 master Floor Area 871 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total ROOM Loads 803 Return Vented Lighting Return Air Ducts Return Fan Ventilation ` 203 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 110,000 14,186 1,710 209 17,120 Total Output Btuh 110,000 0 Output Btuh/s ft 126.3. 819 841 Cooling System 0 0 Output perSystem 37,000 8,945 4,626 203 9,807 Total Output Btuh 37,000 0 .819 1 24,769 6,336 0 Total Output(Tons),3•1 841 Total Output Btuh/s ft 42.5 Total Output s ft/Ton 282.5 28,609 Air S stem CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24AN13136-58CVX110 31,783 0 110.000 Airflow cfm/s ft 1.38 Airflow cfm/Ton 389.2 Outside Air % 16•9 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,783 0 110.000 Outside Air cfm/s ft . 0.23 Note: values above given at AR! conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 203 cfm 71 OF 64 OF 150 °F� 150 OF - Heating Coil Supply Fan a 1,200 cfm 149 F �.� ROOM 72 OF ri COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Co ling Peak 112/78OF Outside Air 203 cfm 71 /59°F LEnerg 78/63°F 53/52°F 53/52.OF CI1 i OF PI 1 DING SAFETY DEPT. c Cooling Coil Supply Fan FOR CONSTRUCT�O 53 / 52 ° 1,200 cfm — -- - 52.0 % DATE-- 70/59°F Pro 6.3 b Energ Soft User Number: 6712 Run Code: 2014-12-04T14.46:01 /D: Page 20 of 39 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Wan C. Smith Residence Date 12/4/2014 System Name HVAC 2 kit Floor Area 864 ENGINEERING CHECKS SYSTEM LOAD. Number of.S stems 1 COIL CFM Total Room Loads 841 Return Vented Lighting Return Air Ducts Return fan Ventilation. 202 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 110,000 14,848 1,696 119 9,802 Total Output Stuh 110,000 0 Output Btuh/s ft 127.3 857 482 Cooling System 0 0 Output perSystem 37,000 8,867 4,597 202 9,788 Total Output Btuh 37,000 0 6,293 0 Total Output(Tons) 3•1 857 482 Total Output Btuh/s ft 42.8 Total Output s ft/Ton 280.2 25,430 20,554 Air System CFM perSystem 1,200 . HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB136-58CVX110 31,767 0 110,000 Airflow cfm/s ft 1.39 Airflow cfm/Ton 389.2 110,000 Outside Air °i° 16.8 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,767 0 Outside Air cfm/s ft 0.23 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 202 cfm 72 OF 64 OF 150 OF 150 OF Heating Coil Supply Fan ° 1,200 cfm 150 F ROOM 72 OF rn COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF . Outside Air 202 cfm 71 /59OF 78/63°F 53/52°F 53/52OF' CI t i OF °—' ° T SAFETY DEPT. R� Cooling Coil Supply Fan FOR CONSTj�UCTIO 3 / 52 OF 1,200 cfm--- 52.0 % �Q DATE 70/59°F En&g Pro 6.3 by Energ Soft User Number: 6712 Run Code: 2014-12-04T14:46:01 /D: Page 21 of 39 4 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Jaclin C. Smith Residence 12/4/2014 System Name Floor Area HVAC 3 & 4 great 2,245 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 3,637 Return Vented Lighting Return Air Ducts Return Fan Ventilation 524 Supply Fan' Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating S stem Sensible Latent CFM Sensible Output per System 110,000 32,866 4,408 674 32,254 Total Output Btuh 220,000 0 Output Btuh/s ft 98.0 1,897 1,585 Cooling System 0 0 Output per System 52,300 23,165 4,133 524 25,436 Total Output Btuh 104,600 0 1,897 1. 59,826 8,541 0 Total Output Tons 8.7 1.585 Total Output Btuh/s ft 46.6 Total Output s ft/Ton 257.6 60,861 Air System CFM per System ?,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 24ANB160-58CVX110-24ANB148 63,103 31,377 220,000 Airflow cfm/s ft 1.78 Airflow cfm/Ton 458.9 220,000 Jan 1 AM Outside Air °i° 13.1 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 63,103 31,377 Outside Air cfm/s ft ' 0.23 Note: values above given at ARI conditions Aug 3M HEATING SYSTEM PSYCH ROM ETRICS Airstream Temperatures at Time of Heating Peak). 26 OF 66 OF 117 OF 117 OF Outside Air 524 cfm Heating Coil Supply Fan 4,000 cfm 117 OF ROOM Sim 72 OF 72 OF CITY ®F FADUI „ ,. DEPT. COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Coolin 'eak R-- A 112178 OF 76 / 66 OF 61 60 OF 61 / 60 OF FOR CONSTRUCTION Outside AirA. c BY 524 cfm Supply Fan DATE _------ Cooling Coil 62 / 60 OF 4,000 cfm -- 71.4 % ROOM 70/64°F 70/64°F EnergyPro 6.3 by Energ Soft User Number: 6712 RunCode: 2014-12-04T14:46:01 ID: Page 22 of 39 L- HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name actin C. Smith Residence Date 12/4/2014 System Name HVAC 5 bed Floor Area 1,112 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,488 Return Vented Lighting Return Air Ducts Return Fan Ventilation 259 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 110,000 16,964 2,183 452 21,541 Total Out ut Btuh 110,000 0 Output Btuh/s ft 98.9 979 1,059 Cooling System 0 0 Output perSystem 55,600 11,470 3,220 259 12,565 Total Output Btuh 55,600 0 979 1 30,393 5,403 0 Total Output Tons 4.6 1,059 Total Output Btuh/s ft 50.0 Total Output s ft/Ton 240.0 36223 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB160-58CVX110 36,223 13,035 110,000 Airflow cfm/s ft 1.80 Airflow cfm/Ton 431.7 Outside Air % 13.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 36,223 13,035 110,000 Outside. Air cfm/s ft 0.23 Note: values above given at ARI conditions Aug 3 PM Jan .1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 259 cfm 72 OF 66 OF 117 OF 117 OF i Heating Coil Suppiy.Fan 117 OF 2,000 cfm ROOM rU 72 OF CITY aOF LA Q AntSAFETY DEPT. COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at.Time of Cooling Pel1i ` —, -. rr- a e-v® Bif 112/78OF Outside Air 259 cfm 70/62 OF 76/65°F 59/58°F 59/58°F }0:" c Cooling Coil Supply Fan 2,000 cfm- I-CO�� �.- FOR CONSTRUCTIO N - �� BY 59 / 58 OF 65.5 % I ROOM =o 70 / 62 OF Energ Pro 6.3 by Energ Soft User Number: 6712 RunCode: 2014-12-04T14.46:01 ID: Page 23 of 39 a ROOM LOAD SUMMARY Project Name Jaclin C. Smith Residence Date 121412014 System Name HVAC 1 master Floor Area 871 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Bedroom Master Bedroom 1 803 14,186 1,710 863 14,186 1,710 209 17,120 NITA ncoT 3UILERINIG FOR C ATE BY PAGE TOTAL 803 14,186 1,710 209 17,120 11 ROOM LOAD SUMMARY. Project Name Date Jaclin C. Smith Residence 121412014 System Name Floor Area HVAC 2 kit 864 . ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Kitchen Dining Kitchen Dining - 1 841 14,848 1,696 841 14,848 1,696 119 9,802 LJI I Y lJ LJ-'► v i v a �-. BUILDING & SAF P FOR C NSTR JCTION PAGE TOTAL TOTAL* ' Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-12-04T14:46:0 841 14,848 1,696 . 119 9, 802 841 14, 848 1, 696 119 9, 802 1LJ • ROOM LOAD SUMMARY Project Name Date Jaclin C. Smith Residence 121412014 System Name Floor Area HVAC 3 & 4 great 2,245 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible' Latent CFM Sensible Greatroom & Hall Greatroom & Hall 1 3,637 32,866 4,408 3,637 32,866 4,408 674 32,254 EMME li�® TOTALM1 W. NEWS I TOTAL Total includes ventilation loa. wip �• 3,637 01�- 32,866 4,408 6741 3Z254. 3,637 32,866 4,408 674 32,254 26 of 39 • • • ROOM HEATING .PEAK LOADS Project Name Jaclin C. Smith Residence Dat e 121412014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 871.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 T Conduction Area U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F — = = = = = = = = = - = = _ = = _ = _ = = = = _ _ - = - = _ = 46 Btu/hr R-38Roof Aftic 871.0 X'. 0.0260 46 1,042 R-21 Wall (W.21.2x6.16) 2,494.1 X 0.0690 46 7,916 Low-E Vinyl 143.9 X 0.2800 46 1,853 Slab -On -Grade penim = 109.0 X X X X X X 0.7300 46 3,660 "R-13 Wall 613.0 0.1020 0 0 . X - X X X X X X, X X X X X X X X X X X X X X X through an interior surface to X 871 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room . 14.00 X 0.266 Height ACM Page Total / 60 ] X AT 14,472 = 2,648 TOTAL HOURLY HEAT LOSS FOR ROOM 17,120 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-12-04T14:46:01 /D: Page 28 of 39 C ] C ROOM HEATING PEAK LOADS Project Name Jaclin C. Smith Residence Date 121412014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Dining Floor Area 864.0 ft2 Indoor Dry Bulb Temperature .. 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value 864.0 X 0.0260 745.6 X 0.0690 178.4 X 0.2800 perim = 44.0 X 0.7300 411.0 X 0.1020 X X x x X X" X X X x X x X X X X X X X X X X X x x x through an interior surface to another room X 864 X 14:00 X 0.266 Area Ceiling Height _ ACH X X X X X X X x x X X X X. X x x x X x. X X X X X X X x x X x AT °F Btu/hr R-38Roof Attic 46 = = _ 1,033 R-21 Wall (W.21.2x6.16) 46 2,367 Low-E.Vinyl 46 2,298 Slab -On -Grade 46 = c 1,478 'R-13 Wall 0 0 c _ _ - = = = _ = = = _ = _ = _ = = = - _ _ p OE l 6 - FEN D UCTION FOR G = Page Total DATE / 60 X 46 AT Items shown with an asterisk. denote denote conduction Infiltration:[ 1.00 X. 1.b64 Schedule Air Sensible Fraction By 7 17 TOTAL HOURLY HEAT LOSS FOR ROOM 9,802 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-12-04T14.46:01 ID: Page 29 of 39 • ROOM HEATING PEAK LOADS Project Name Jaclin C. Smith Residence Date 121412014 ROOM INFORMATION DESIGN CONDITIONS Room Name Greatroom & Hall Floor Area 2,2415.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X ..X X X X X X X X X X X X X X X AT'F Btu/hr R-38 Roof Attic 2,245.0 0.0260 46 c 2,685 R-21 Wall (W.21.2x6.16) 3,297.9 0.0690 46 = 10,468 Low-E Vinyl 474.0 0.2800 46 = 6,105 Wood Door 20.1 0.5000 46 = 462 Slab -On -Grade pen .m = 170.0 0.7300 46 = = 5,709 'R-13 Wall 714.0 -0.1020 0 0 = = _ = = - = - = = = = - _ - = = = - = - - = Items shown with an asterisk.(') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,245 X Area another-roomF 14.00 X Height �g�,TO I ®INV ra 5, 29 so 6 _ -6, 5 1CONSTRUCTION TOTAL HOURLY HEAT LOSS FOR ROOM 32,244, DATE BY EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-12-04T14:46:01 Page 30 of 39 • • ROOM HEATING PEAK LOADS Project Name Jaclin C. Smith Residence . 777. Date 121412014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2,3 & 4 Floor Area 1,112.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X x X X X X X X X X X. to Ceiling U-Value. X . X X X X X X X X X X X X X X X. X X X X X x X X X X X. X X S AT °F = = = = = = = = _ = _ = - = - _ _ _ _ _ = = = = _ _ _ - _ (_� reVY 4( Btu/hr R-38 Roof Attic q 1,112.0 0.0260 46 1,330 R-21 Wall (W..21.2x6.16) 3,048.1 0.0690 46 9,675 Low-E Vinyl 161.9 0.2800 46 2,085 Slab -On -Grade perim = 151.0 0.7300 46 5,071 `R-13 Wall 741.0 0.1020 0 0 _ TA rter Items Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible through an interior surface X 1,112 X Area another roo;CH 14.00 Height SP-a9z FQp;�C+Q ATFraction E _� 6Y _ 18, , 0 3,38 . - TOTAL HOURLY HEAT LOSS FOR ROOM 21,541 EnergyPro 6.3 by EnergySoft User Number. 6712 Run Code: 2014-12-04T14.46:01 /D: Page 31 of 39 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name • Jaclin C. Smith Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature Floor Area 871.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Tem erature 70 OF Outdoor Daily Ranqe: C � J Oaaoue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) "R-13 Wall Orientation Area X X X X ` X X X X X U-Factor X X X X. X x X X X CLTD' = = = = = = = = = 871.0 0.026.0 56.0 338.0 0.0690 27.0 378.0 0.0690 31.7 1,152.1 0.0690 29.3 626.0 0.0690 31.2 613.0 0.1020 0.0 Page Total Items shown with an asterisk"(') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD)' Fenestration NEW NEW NEW NEW NEW NEW NEW NEW NEW Gain Orientation (NE) (SW) (SIM (SIM (SK9 (sK9 (SIM (SW) (SWJ 121412014 112 OF 78 OF 34 OF Btu/hr 1.268 1 1 6,4011 Shaded Area Unshaded GLF . Area X 16.0 + 40.0 X 16.0 + 4.0 X 16.0 + 6.0 X 16.0 + 3.9 X 16.0 + 6.0 "X 16.0+ 7.5X X 16.0 + 12.5 X 16.0 + 6.0 X 16:0 + 6.0 X X X X X X X X GLF = = = = = = = - Btu/l 0.0 22.0 0.0 20.3 0.0 20.3 0.0 20.3 0.0 20.3 0.0 20.3= 0.0 20.3 0.0 20.3 0.0 1 20.3 Page Total 1 2.6 Occupants X 245 Btuh/occ. 871 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.94 X 55.88 X 42 = Air Sensible CFM ELA AT 860 81 122 79 122 152 254 122 Btu/hr 640 1,486 2,336 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM t41. Latent Gain C 2.s BUILDING & SAFETYB@WrT Occupants Occupants X 15 oa�c.Btuh/®�2RI� D 405 0 x x F//'STON "Infiltration: 4,771 X 0.94 55.88 0.00523 = FOR CONR 1,305 Air. Sensible CFM ELA AW . • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM BY • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Jaclin C. Smith Residence 12/4/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name MasterBedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 871.0 ft2 Outdoor Wet Bulb Temperature 78.OF Indoor Dry Bulb Temperature 70 OF 1 Outdoor Daily Range: 34 °F Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X X X = X X = X X - X. X X X = X X = X X _ Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1,. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr NEW (SK9 0.0 X 16.0 + 6.0 X 20.3 = 122 NEW (NW) 0.0. X 16.0 + 6.0 X 27.5 = 165 NEW (NW) 0.0 X 16.0 + 40.0, ,X 27.5 = 1,101 X + X _ X + X = X + X = X + X = X + X = X + X = Page Total 1,388 Internal Gain Btu/hr Occupants 2•6 Occupants X,1 245 Btuh/occ. = 640 Equipment 871 Floor Area X 0.50 w/sgft = 1,486 Infiltration: 1.064 X 0.94 X 55.88 X 42 = 2,336 Air Sensible CFM ELA. AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM A UUIM, s & SAFEV D Latent Gain BUILDING r Occupants 26 Occupants X 15 Btuh/o(!01..a�)� e" 405 FOR CONSTR 4 771 Infiltration: X 0.9.4 X 55.88 X 0.00523 = 1;305 Air Sensible CFM ELA pW BY DATE ----� TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 405 EnemyPro 6.3 by EnemySoft User Number: 6712 Run Code: 201412-04T14:46:01 ID: Pa a 33 of 39 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Jaclin C. Smith Residence 12/4/20.14 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Dining outdoor Dry Bulb Temperature 112 OF Floor Area 864:0 ft-' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic' (W) 864.0 X, 0.0260 X 77.0 = 1,730 R-21 Wall (W.21.2x6.16) (NE) 359.6 X 0.0690 X 33.0 = 819 R-21 Wall (Vt!21.2x6.16) (Nim 386.0 X 0.0690 X 50.4 = 1,342 "R-13 Wall 411.0 X 0.1020 X 0.0 = 0 x X — X X = X X - X X = X X = Page Total 3,890 Items shown with an asterisk (") denote conduction through,an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) , Shaded .Unshaded Fenestration Orientation Area GLF • . Area GLF Btu/hr NEW (NE) 0.0 X 19.5 + 102.4 X 26.4 = 2,701 NEW (NW) 0.0 X 19.5 + 76.0 X 50.4 = 3,830 X + X. _ X + X = X + X = .X + X X +:. X X + .. X = X + x = Page Total 6,531 Internal Gain Btu/hr Occupants 2 6 Occupants X 245 Btuh/occ. = 635 Equipment 864 Floor Area . X 0.50 w/sgft _ 1,474 Infiltration: 1.064 X 0.94 X 55.43 X , • . 42 Air Sensible . CFM EIA, AT F 1 A u O L ll 1� TOTAL HOURLY SENSIBLE HEAT GAIN' FOR ROOM 14,848 AHVhUvr Latent Gain CONSTRUCT(IRWhr FOR Occupants 2 6. Occupants X r 1 5 Btuh/occ. = 402 Infiltration: 4,771 X 0.94 X. 55.43 X 0.00523 = DATE BY, Air Sensible CFM'' ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM. 402 EnemyPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-12-04T14,46:01 ID: Page 34 of 39 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name 7121412014 ate • Jaclin C. Smith Residence ROOM INFORMATION DESIGN CONDITIONS Room Name GreStroom & Hall Outdoor Dry Bulb Temperature 112 °F Floor Area 2,245.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF r� LJ Ooaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (NE) (E) (SE) (S) (S) (SW) (1/109 (NW) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = 0 = .2,245.0 0.0260 56.0 197.0 0.0690 27.0 197.6 0.0690 33.0 1,467.0 0.0690 31.7 357.9 0.0690 26.0 20.1 0.5000 26.0 185.0 0.0690 29.3 192.0 0.0690 33.0 702.0 1 0.06901 31.2 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration NEW NEW NEW NEW NEW NEW NEW NEW NEW Oriont2finn (NE) (E) (SE) (SE) (SE) (SE) (SE) (SE) (SE) Page Total Shaded Unshaded Area X X X X X X X. X X GLF Area + 13.0 X X X X X X X X X GLF = = = = = = = 0 - 0.0 16.0 22.0 0.0 16.0 + '13.0 32.6 0.0 .16.0 + + 11.0 23.1 0.0 16.0 11.0 23.1 0.0 16.0 + 11.0 23.1 0.0 16.6 + + 12.5 23.1 0.0 16.0 25.0 23.1 0.0 16.0 + 12.5 23A 0.01 1 16.0 + 13.01 1 23. 1 Page Total Internal Gain Occupants LE Occupants X 245 Btuh/occ.E ui ment Floor Area X 0.50 w/sgft = Infiltration: 1:064 X 0.94 X 144.04 X 42 = Air Sensible CFM EI.A AT rCITY OF LA TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 6 7 Occupants X 155 Infiltration: 4,771 X. 0.94 X 144.04 X 0.00523 = Air Sensible CFM- ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Code: Btu/hr 642 261 374 437 1, 509 10,5141 Btu/hr 286 424 255 255 255 289 579 289 301 1,650 3, 831 .. 866 C Li FOR CONSTRUUMN uh/occ. = 1,044 DATE B 1, 444 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Jaclin C. Smith Residence 12/4/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Greatroom & Hall Outdoor Dry Bulb Temperature 112 OF Floor Area 2,245.0 ft' Outdoor Wet Bulb Temperature 78 OF. Lin dor D Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces 'R-13 Wall Area U-Factor CLTD' 714.0 X 0.1020 X 0.0 = X X = X X = X X = X X = X. X = X X = X X = X J X I= Page Total Items shown with an asterisk (') denote conduction through an.interior surface to another room 1. Cooling Load Temperature Difference (CLTD) I FanPgtrntinn NEW NEW NEW NEW NEW NEW NEW NEW NEW I Internal Gain rientation Ariantatinn (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) Shaded . Unshaded Area X X X X X X X X X GLF Area + 13.0 + 13.0 X X X X X X X X GLF = = = = = = = - 0.0 16.0 23.1 0.0 16.0 23.1 0.0 16.0 + 13.0 23.1 0.0 16.0 + + 6.0 23.1 0.0 16.0 6.0 23.1 0.0 16.0 + + 6.0 23.1 0.0 16,0 6.0 23.1 0.0 16.0 + + 6.0.X 23.1 0.0 16.0 1 6.01 23.1 6.7 Occupants X 245 Btuh/occ. 2,245 Floor Area X 0.50 w/sgft Page Total Btu/hr Btu/hr 301 301 301. 139 139 1.39 139 139 1, Btu/hr 1,650 3,831 Infiltration: 1.064 Air Sensible X 0.94 CFM X 144.04 ELA X 42 = 6,021 AT TOTAL HOURLY SENSIBLE HEAT GAIN.FOR'ROOM 3 ass BUILDIN(a Latent Gain PPROVE Occupants 6 7 Occupants X 15 �,h(of�(vSTRUC� Infiltration: 4,771 X 0.94 X 144.04 X 0.005.3 = Air Sensible CFM ELA AW DATE BY Btu/ Oi TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Jaclin C. Smith Residence 121412014 ROOM INFORMATION DESIGN CONDITIONS Room Name Greatroom & Hall Outdoor Dry Bulb Temperature 112 °F Floor Area 2,245.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btulhr X X = X X = X X - X X = X X - X X = X X _ X X = X X = Page Total o Items shown with an asterisk (') denote conduction though an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF . Btulhr NEW (SE) 0.0 X 16.0 + 6.0 x 23.1 = 139 NEW (SE)'. 0.0 X 16:0 + 6.0 X 23.1 = 139 NEW (SIM 0.0 X 16.0 + 12.5 X 20.3 = 254 NEW (SIM 0.0 X 16.0. + 12.5 X 20.3 = 254 NEW (W) 0.0 X 16.0 + 18.0 X 32.6 = 587 NEW (NW) : 112.8 X 16.0 + 79.2 X 27.5 = 3,984 NEW (NW) 0.0 X 16.0 + 30.0 X 27.5 = 626 X + X = X + X = - Page Total 6, 983 Internal Gain Btulhr Occupants fi 7 Occupants X 245 Btuh/occ. = 1,650 Equipment 2,245 Floor Area X 0.50 W/s ft = q 3,831 Infiltration: 1.064 X 0.94 X 144.04 X 42 = 02 Air Sensible CFM ELA• AT CITY ®� III -DING &SAFETY DEPT. TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,86 Latent Gain FOR CONSTRUCTIOBN thr Occupants 6 7 -Occupants X] 155 Btuh/occ. = 1,044 Infiltration: 4,771 X 0.94 X 144.04 x 0.00523 _ DATE BY--_- --- 3,364 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,044 Ene Pro 6.3 by Ene Soft User Number: 6712 RunCode: 2014-12-04T14:46:01 ID: Page 37 & 39 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name e Dat Jaclin C. Smith Residence 121412014 ROOM INFORMATION DESIGN CONDITIONS Room. Name Bedro0'M 2,3 & 4 Floor Area 1,112.0'ft2 Indoor Dry Bulb Temperature 70 OF Outdoor Dry Bulb Temperature 112 °F Outdoor Wet Bulb Temperature 78 OF .Outdoor Daily Range: 34 OF Op ague Surfaces Orientation (W) Area 1,112.0 , X 1,320.0 X 479.1 X 577.0 X - 672.0 X 741.0 X X" X X U-Factor CLTD' X 56.0 = X 27.0 = X 31.7 = X 29.3 = 'X 31.2 = X 0.0 = X = X = X = Btulhr R-38 Roof Attic. 0.0260 1,619 R-21 Wall (W.21:2x6.16) (NE) 0.0696 2,459 R-21 Wall (W21.2x6.16) (SE) 0.0690 1,047 R-21 Wall (W.21.2x6.16) (svio 0.0690 1,168 R-21 Wall (W.21.2x6.16) (NW) 0.0696 1,445 "R-13 Wall 0.1020 0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration NEW NEW NEW NEW NEW NEW NEW NEW NEW Area X X X X X X X X X GLF I + + + + + + + + + .Area X X X X X X X X X GLF = = = = = = = = = 0.01 16.0 6.0 22.0 0.0 16.0 30.0 22.0 0.0 16.0 6.0 22.0 0.0 16.0 6.0 22.0 0.0 16.0 6.0 22.0 0.0 16.0 6.0 22.0 0.0 16.0 6.0 22.0 0.0 16.0 3.9 23.1 0.0 16.0 42.0 23.1 Page Total Internal Gain Occupants 3.3 Occupants X 245 Btuh/occ: _ Equipment 1,112 Floor Area X 0.50 -w/sgft = Infiltration: 1.064 X . 0.94 X 71.35 X 42 Air Sensible CFM ELA AT CfF-T�7qF LA QUIN TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13 U I LU I.IN U Latent Gain AP R CONSTRUCTION Occu ants 3 3 Occupants X . 155 Btuh/occ. _ Infiltration: 4,771 X 0.94 X 71.35 X. 0.00523 = DATE BY Air Sensible CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7. 737I Btu/hr 132 660 132 132 132 132 132 90 972 Btulhr 817 1,898 --"2.982 to/hr • E • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project, Name Date Jaclin C. Smith Residence 7121412014 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2,3 & 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,112.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation ` Area U-Factor CLTD' Btulhr X X = X X = X X - X X = X X = X. X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr NEW (SK9 6.0 X 16.0 + 12.5 X 20.3 = 254 NEW (SK9 0.0 X 16.0. + 25.0 X 20.3 = 508 NEW (SK9 0.0 X 16.0 + 12.5 . X 20.3 = 254 X + X X + X = X + . X = X + X _ X + X _ X x = Page Total 1,01 Internal Gain Btu/hr Occupants 33 OccupantsX 245 Btuh/occ. = 817 Equipment 1,112 Floor Area X 0.50 w/sgft = 1,898 Infiltration: 1.064 X 0.94 X 71.35 X 42 _ Air Sensible / 9 C' 1 I OF. CFM ELA AT FBUILDING & SAFETY DEPT. TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,96 FOR CONSTRUCTION Latent Gain Btu/hr Occupants 3 3 Occupants X 4155 Btuh/occ. = 51 TEInfiltration: 4,771 X 0.94 X 71.35 X= 1,666 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 517 EnemvPro 6.3 by EnemySoft User Number: 6712 RunCode: 2014-12-04T14:46:01 ID: Page 39 6! 39 CEFe.rIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 %Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Page 1 of 12 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi GENERAL INFORMATION 01 Project Name Jaclin C. Smith Residence 02 Calculation Description Title 24 Analysis 03 Project Location Lions Gates #10 04 A City La Quinta 05 Standards Version Compliance 2015 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 120 . 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 5092 15 Number of Zones 4 16 Slab Area (FT2) 5092 . 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A 21 Glazing Percentage (%) 18.8% COMPLIANCE RESULTS 01 Building Complies Wdomputer Performance 02 This building incorpo atesfeatu s; that;reVire field testing and/dr verification by a certified HERS�at�ertunderthe supervision of a CEC-approved HERS provider. 03 This building incorporates one o�r- moie Special._Featuees'shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft) Standard Design Proposed. Design Compliance Margin Percent Improvement Space Heating 4.84 4.83 0.01 0.2% Space Cooling 126.12 124.99 1.13 0.9% IAQ Ventilation 1.30 1.30 0.00 0.0% Water Heating 5.04 5.62 -0.58 r%1TV 1lt5° Photovoltaic Offset --- 0.00 0.00-- -.. cs III rnln _ C Compliance Energy Total 137.30 136.74 0.56 i v DATE I APT. w4.l1. 0 Registration Number: 214-No092597B-000000000-0000 Registration Date/Time: _ 2014-12-04 14:40:57 HERS-Provi �C6ICERT0S in CA BuildingEnergy Efficient Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Repo���OP A2 V"Uuip64M. -- - r � ter,•,-..- -_ . ' . _—•--•=:.-+�• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Jaclin C. Smith Residence - Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Page 2 of 12 Calculation Description: Title 24 Analysis - Input File Name: Smith Res -Lions Gate-STRACTS-14.icml ENERGY DESIGN RATING_£ This is the sum of the annual TDV energy 4onsumption for energy use components included in the performance'compliance app oach'ia ttie Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components.not regulated by Title 24 Part.6 (such as domestic appliance"s and__cconsumerelectromcs) and accounting for the annual TDV energy offset by an on -site renewable energy system.- Reference Energy Use "z f $ ;Energy D ' I' `Rating Margin Percent Improvement ' _ Total Energy (kTDV/f2)" ' 174.32 " '� ti .:173 76 . 0.56 `. 0.3% t . r . " includes calculated Appliances and Miscellaneous Energy Use (AMEU) _ +, -5 : • i - , .+ , ♦ �• F BUILDING - FEATURES INFORMATION , 01 02 03 _ 04 05 ,. 06 •07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Jaclin C. Smith Residence 5092 1 - 12 4` Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 - L. I I Y U i— L/-! 'lid U 11N I/ O BUILDING &SAFETY DEPT. APPROVED FOR CONSTRUCTION f DATE BY p _ HE-R-S4�Mer. Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CFI R-PRF-01 Page 3 of 12 ZONE INFORMATION 01 02 03 04 05- 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Bedroom Conditioned HVAC 1 masterl 871 14 DHW Sys 1 Kitchen Dining Conditioned HVAC 2 kit2 864 14 DHW Sys 1 Greatroom & Hall Conditioned HVAC 3 & 4 great3 2245 14 DHW Sys 1 Bedroom 2,3 & 4 Conditioned HVAC 5 bed4 1112 14 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) 30d Wall Master Bedroom R721 Wall (W.21.2x6.16) 30 _ Right 378 40 90 120d Wall Master Bedroom R-21 Wall (W.21.2x6.16) 120 Front 378 0 90 210d Wall Master Bedroom _ R-21 Wall (W.21.2x6.16) _ 210 Left 1210 57.9 90 300d Wall �Master Bedroom ` '. t< R-21 Wall (W 21 2x6.16) tf'300V Bade 672 46 90 Roof (' Maste�Bedrdom'" � �R-38 Roof Attic'' = A 871 30d Wall 2 %,W KdchenLDirnng ! ' 30 . ti��; '+�' Right 462 102.4 90 300d Wall 2 Kitchen Dining i R=21 Wall (W.21.2x6.16) 300 Bade 462 76 90 Roof 2 Kitchen Dining R-38 Roof Attic 864 30d Wall 3 Greatroom & 1­1611 R-21 Wall (W.21.2x6.16) 30 Right 210 13 90 E Wall Greatroom & Hall R-21_ Wall (W.21.2x6.16) 90 specify - 210 13 90 120d Wall 2 Greatroom & Hall R-21 Wall (W.21.2x6.16) 120 Front 1650 183 90 S Wall Greatroom & Hall R-21 Wall (W.21.2x6.16) 180 specify - 378 0 90 210d Wall 2 Greatroom & Hall R-21 Wall (W.21.2x6.16) 210 Left 210 25 90 W Wall Greatroom & Hall R-21 Wall (W.21.2x6.16) 270 specify - 210 18 90 300d Wall 3 Greatroom & Hall R-21 Wall (W.21.2x6.16) 300 Bade 924 222 90 Roof 3 Greatroom & Hall R-38 Roof Attic 2245 30d Wall 4 Bedroom 2,3 & 4 R-21 Wall (W.21.2x6.16) 30 Right 1386 C T ION— Registration Number: 214-No092597B-000000000-0000 Registration Date/Time:., 2014-12-04 14:40:57 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence CalculationDate/Time: 14:31, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xm1 CFI R-PRF-01 Page 4 of 12 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 No No Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time:2014-12-04 14:40:57, CA Building Energy Efficiency Standards - 2013 Residential Compliance • Report Version- CF1R-10172014-651 f CITY OF LA QUINTA I BUILDING & SAFETY DEPT. 4, PROVED FO.=i CONSTRUCTION DATE BY i HERS Provider: CaICERTS inc. Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CFI R-PRF-01 Page 5 of 12 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading NEW Window 30d Wall (Right-30) - - 1 40.0 0.28 0.28 Insect Screen (default) NEW 2 Window 210d Wall (Left-210) --- -- 1 4.0 0.28 0.28 Insect Screen (default) NEW 3 Window 210d Wall (Left-210) - -- 1 6.0 0.28 0.28 Insect Screen (default) NEW 4 Window 210d Wall (Left-210) - - 1 3.9 0.28 0.28 Insect Screen (default) NEW 5 Window 210d Wall (Left-210) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 6 Window 210d Wall (Left-210) - - 1 7.5 0.28 0.28 Insect Screen (default) NEW 7 Window 210d Wall (Left-210) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 8 Window 210d Wall (Left-210) - 1 6.0 0.28 0.28 Insect Screen (default) NEW 9 Window 210d Wall (Left-210) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 10 Window 210d Wall (Left-210) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 11 Window _ _ 300d Wall.(Bacl-30t)), 1 6.0 0.28 0.28 Insect Screen (default) NEW 12 Window f " r t' 3ddd-Wall (Back=30U) �- 1 40.0 0.28 0.28 Insect Screen (default) NEW 13 Window i30d Wall 2 (Right=30)'�f_ - �'=-� ��1 �102.4 0.28 0.28 Insect Screen (default) NEW 14 Window �..¢� '.;�d "300d Wall 2.(Bacli-300)--7 76.0 0.28 0.28 Insect Screen (default) NEW 15 Window 30d Wall 3 (Right-30) - - -- 1 13.0 0.28 0.28 Insect Screen (default) NEW 16 Window E Wall (- specify -90) --- - 1 13.0 0.28 0.28 Insect Screen (default) NEW 17 Window 120d Wall 2 (Front-120) -- -- 1 11.0 0.28 0.28 Insect Screen (default) NEW 18 Window 120d Wall 2 (Front-120) - 1 11.0 0.28 0.28 1 Insect Screen (default) NEW 19 Window 120d Wall 2 (Front-120) - -- 1 11.0 0.28 0.28 Insect Screen (default) NEW 20 Window 120d Wall 2 (Front-120) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 21 Window 120d Wall 2 (Front-120) -- - 1 25.0 0.28 0.28 Insect Screen (default) NEW 22 Window 120d Wall 2 (Front-120) - - 1 12.5 0.28 0.28 Insect Screen (default) NEW 23 Window 120d Wall 2 (Front-120) - - 1 13.0 0.28 -2 nse een RN Or NEW 24 Window 120d Wall 2 (Front-120) - - 1 13.0 0.2,8.2 ristAcrAU NEW 25 Window 120d Wall 2 (Front-120) - - 1 13.0 0.28 UR-3I, G Innsec er ( e NEW 26 Window 120d Wall 2 (Front-120) - - 1 13.0 0.2b 0..128P PI`' S ri d fa It) NEW 27 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 _28�@�e NEW 28 Window 120d Wall 2 (Front-120) - - 1 6.0 0.2d 0.28 Insect Screen (default) NEW 29 Window 120d Wall 2 (Front-120) -- - 1 6.0 0.28` r `T 0.28 Insect ;�peen default Registration Number: 214-No092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Calculation. Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CFI R-PRF-01 Page 6 of 12 NEW 30 Window 120d Wall 2 (Front-120) - -- 1 6.0 0.28 0.28 Insect Screen (default) NEW 31 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 32 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 33 Window 120d Wall 2 (Front-120) - - 1 6.0 0.28 0.28 Insect Screen (default) NEW 34 Window 120d Wall 2 (Front-120) -- -- 1 6.0 0.28 0.28 Insect Screen (default) NEW 35 Window 210d Wall 2 (Left-210) ---- --- 1 12.5 0.28 0.28 Insect Screen (default) NEW 36 Window 210d Wall 2 (Left-210) -- -- 1 12.5 0.28 0.28 Insect Screen (default) NEW 37 Window W Wall (- specify -270) - - 1 18.0 0.28 0.28 Insect Screen (default) NEW 38 Window 300d Wall 3 (Back-300) 24.0 8.0 1 192.0 0.28 0.28 Insect Screen (default) NEW 39 Window 300d Wall 3 (Back-300) - - 1 30.0 0.28 0.28 Insect Screen (default) NEW 40 Window 30d Wall 4 (Right-30) - --- 1 6.0 0.28 0.28 Insect Screen (default) NEW 41 Window 30d Wall 4 (Right-30) - --- 1 30.0 0.28 0.28 Insect Screen (default) NEW 42 Window 30d Wall 4 (Right-30) --- -- 1 6.0 0.28 0.28 Insect Screen (default) NEW 43 Window 30d Wall 4 (Right-30) -- --- 1 6.0 0.28 0.28 Insect Screen (default) NEW 44 Window 30d Wa11.4,(Right,30) �r-s+e*� _ 1 6.0 0.28 0.28 Insect Screen (default) NEW 45 Window '! ^� 3l)d Wall 4 (Ri66t-30) , `�-- , ; ' 1 6.0 0.28 0.28 Insect Screen (default) NEW 46 Window t F �30d61Nal14 (Right 30)'Y. '_=. f trn,rl /m 1 6.0 0.28 0.28 Insect Screen (default) NEW 47 Window `>,,,'� " ' `120d 1Nall.3-(Front-120) '" s ' , yK - =`= , ' *yf �1,[,�a 3.9 0:28 0.28 Insect Screen (default) NEW.48 Window 120d Wall 3 (Front-120) ---- --- 1 42.0 0.28 0.28 Insect Screen (default) NEW 49 Window 210d Wall 3 (Left-210) -- -- 1 12.5 0.28 0.28 Insect Screen (default) NEW 50 Window 210d Wall 3 (Left-210) - - 1 25.0 0.28 0.28 Insect Screen (default) NEW 51 Window 210d Wall 3 (Left-210) - - 1 12.5 0.28 0.28 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door S Wall 20-w r Q t_. . . - - - OVERHANGS AND FINS ' tSUI ED II 71 _ 01 02 03 04 05 06 07 08 09 10 11 A�12 l' I 4 Overhang Left Fin I FUK URig Window Depth Dist Up Left Extent Right Extent Flap Ht Depth Top Up DistL Bot Up r.RVt;h Top Up 'st R Bot Up NEW 38 18 0.1 18 18 0 0 0 0 0 0 0 Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Calculation. Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi CFI R-PRF-01 Page 7 of 12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers 2x4 Top Chord of Cavity/Frame: no insul. /2x4 Top Chrd Roof Truss @ 24 in. Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board - Cavity/ Frame: R-21 / 2x6 R-21 Wall (W.21.2x6..16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS 0.1 02 ' 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab`` Master Bedroom None 0.8 No Covered Slab 2 `, Kitchen Dining,;' 8641^''s %i k,44: None 0.8 , No Covered Slab 3 y\ } Greatroom &"Hall ""s �I i'•'.e iRr' F.. !4' �•� , 2245 ' `-erg} '3�. 170 , •f� }y v None 0.8 No Covered Slab 4 ` ` Bedroom 2 3 t£'4'� ,, . *' 1112 151 " None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION s 01 02 03 , 04 Quality Insulation Installation (QII) I. Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of -(seat p p: of FFa� Ion' 'TJ DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 I r�l NI R RAFM pEP DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 - r-3 r0n= Registration Number: 214-No092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 - FOR CONSTRUCTION DATE BY HERS Provider: CaICERTS inc. Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input file Name: Smith Res -Lions Gate-STRACTS-14.xmi CF1 R-PRF-01 Page 8 of 12 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss .(Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A. N/A N/A N/A N/A N/A DHW Sys 1 - 1/2 N/A N/A N/A N/A` N/A N/A HVAC SYSTEMS 01.021Y y' `03 04 05 06 07 f Heating"Systee ` Ir Cooling System Distribution.. Floor Area Name System�Type.. Name Ducted Named r?' Ducted r System Fan System Served # ,� e, HVAC 1 masterl Other Heat/Cool } Heating Component 1 _ Yes _ ._, . „ Cooling Component 1 . Yes Air Distribution 871 System 1 HVAC 2 kit2 Other Heat/Cool Heating Component 2 Yes Cooling Component 2 Yes Air Distribution System 2 864 HVAC 3 & 4 great3 Other Heat/Cool Heating Component 3 Yes Cooling Component 3 Yes Air Distribution System System 3 HVAC 3 & 4 great3 Other Heat/Cool Heating Component 3 Yes Cooling Component 3 Yes Air Distribution System System 3 HVAC 5 bed4 Other Heat/Cool Heating Component 4 Yes Cooling Component 4 Yes Air Distribution System 4 1112 Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY HERS Provider: CaiCERTS inc. Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith' Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi CF1 R-PRF-01 Page 9 of 12 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 CntrlFurnace - Fuel -fired central furnace 80 AFUE_ HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification 'Cooling Component 1 SplitAirCond - Split air conditioning 13 16 No No Cooling Component system 1-hers-cool Cooling Component 2 SplitAirCond - Split air conditioning 13 16 No No Cooling Component system _ x..+ .,t--T. 2-hers cool Cooling Component 3 SplitAirCond -' Split air conddi&ir g r 13 a "16 0.` No No Cooling Component ste - s Y xm` : } 1f a .- .�. 3-hers-cool Cooling Component 4 S IitAirCond - S Id`airaohAlhiornn p p� 9 2 13.rf1 " t s 16 t` ##� No No CoolingComponent p system x. , F - 4-hers-cool HVAC COOLING - HERS VERIFICATION 01 02, 03- 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required '350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required uice CITY OF, LA UUIN I /A BUILDING & SAFETY DEPT. PIPF"" ROVED FOR CONSTRUCTION DATE BY Registration Number: 214-N0092597B-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 R Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014=651 Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 - Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Page 10 of 12 ' Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xmi 6 HVAC - DISTRIBUTION SYSTEMS ' 01 02 03 04 05 106 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 1-hers-list Air Distribution System 2 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution , •t System 2-hers-list Air Distribution System 3 " Ducts located in attic Sealed and tested T 8 ` - F Attic Attic None y Air Distribution System 3-hers-dist a Air Distribution System 4 Ducts located in attic, Sealed and tested 8 Attic. -� Attic. „ , N_ one -° Air Distribution System 4. hers -disc' '. HVAC DISTRIBUTION -HERS VERIFICATION ,. 01 02:.: 03„ 04 05 .. 06 - 07 _ ' Duct Leakage ' ° r Verified' Duct Design Low -leakage - Name Verification F: Duct LeaTare % a ,`4' tVe^rfed 9 g ( ) 4 �.._, Duct Location Return Supply , Air Handler ' Air Distribution System Required " j rw� 60 -� ,Not ui .l2egred.. Not Required Not Required1-hers dist o Air Distribution System'- "a. ''' Required k3,, x'"' `:v.: N+`" ... ' 6 0 a„-1;"4.4.. '�4+. Not Required 'Not Required Not Required 2-hers-dist ; 1T _ Air Distribution System 3-hers-dist "' =`; ' Required .. >- 6 0 ': "' a s• Not Required ' ' Not Required ` Not Required - Air Distribution System Required 6.0 Not Required Not Required :: Not Required - 4-hers-dist - •'+ r a S. HVAC - FAN, SYSTEMS- 01 02 03 04 Name Type -Fan Power (Watts/CFM) HERS Verification HVAC Fan 1, Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 u f I T AvAE F - e - HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 ! UI UI WXc e _ . HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 A HPe Fa°n 4- a ��f HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 Registration Number: 214-N0092597B-000000000-0000 , CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-12-04 14:40:57 Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-12-0414:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE .COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation Date/Time: 14:31, Thu, Dec 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CFI R-PRF-01 Page 11 of 12 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58. HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 0.58 HVAC Fan 4-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification D'WellingUnit 148.42 0.25 ' . Default 0 Required COOLING VENTILATION - 01 ; 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 /n"" �s61 x s,z ?a _. 0.52459 1 �•�_ WH Fan 2a p, r `%'1'.; *>61t, ,, � ; / 0.52459, 1 WH Fan 3 61' ! i ., .. ir. "� .f'f '0.524593 1 :+.�,r r WH Fan �� ;.*' "' 9 r .6,1 �'` ._ ';,"" .:' $ ""a�;k�q t+ 4r'ty''0:52459 1 CITY OF LA QUINTA BUILDING & SAFETY DEPT. � P"ROVED FOR CONSTRUCTION f DATE BY Registration Number: 214-NO09259713-000000000-0000 Registration Date/Time: 2014-12-04 14:40:57 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-04 14:34:02 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Jaclin C. Smith Residence Calculation DatefTime: 14:31, Thu, Dec 04, 2014 " Calculation Description: -Title 24 Analysis ` Input File Name: Smith Res -Lions Gate-STRACTS-14.xml CF1 R-PRF-01 Page 12 of 12 , DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. * . Documentation Author Name:' , - Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. - 2014-10-31 07:58:37 Address: �. • ,- ' -� z� CEA/HERS Certification Identification (If applicable): , , „- 77085 Michigan Drive City/State/Zip:.. .. Phone: Palm Desert, CA 92211 . , '° - ; : (760) 200-4780 ? w• + r RESPONSIBLE PERSON'S DECLARATION STATEMENT • " - ••, s ' �• i, �- �. ' _ x . ' . , ' I certify the following under penalty of perjury, under the laws of the State of California: r'L . " • ' • , z - r P` 1- 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for thelbuilding design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title'24, Part•1 and Part 6 of the California Code of. • .: {• •' Regulations. ' ...�, , r, ;. ', - .', • - ,- 3. The building design features -or. system.design features identified -on this Certificate of Compliance are _consistent,with the information provided on other applicable compliance documents .-.� � .'vat. , - `m •. � FN `k .a..' h a .� • worksheets, calculations, plans and specifications submitted tb� thre enforc�ement�agency for approval?with this building permit application. Responsible Designer Name: „ • ti` �x...x �'�w. Responsible Designer Signature: ti . �' J•Y Tim Scott F r IGIJl/�GOG!/ 5'�.rrf"�'� Company: y24, Date Signed ,. - a Scott Design and Title Inc.- 2014-12-04'14 40:57 ` 4 Address: ,. z c , ; I �; t ;s: License:. 77085 Michigan Drive ..s na City/State/Zip: „ ! .. Phone: Palm Desert, CA 92211 F `., -` �• (760) 200-4780 t _ ... =r-• . • f ` . -- •,' M1' ate. -.- +_,h> � . - .' -1. — � � _ - - `' CITY O1= LA.Q, UINTA BUILDING &SAFETY'DEPT. Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibrlrt f r r ` - FOF;rMION information.. - " [DATE BY Registration Number: '214-N0092597B-000000000-0000 - Registration Date/Time: 2014-12-04 14:40:57 ' HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-04 14:34:02 .