BRES2015-0305r
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
I
c&'r 4 XP Qu&rcu
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/1/2015
Application Number:
BRES2015-0305
Owner:
Property Address:
49215 VISTA VENTURA
GEORGE KOSMOS:
APN:
658220005
601 UNION ST STE 3900
Application Description:
KOSMOS / 255 ADDITION FAMILY ROOM
SEATTLE, WA 92253
Property Zoning:
Application Valuation:
$80,090.40
Applicant:
GREGORY JOHNSON CORP DBA G 10H
Contractor: ��
GREGORY JOHNSON COR m
J�
�p
78365 HIGHWAY 111 SUITE
177
78365 HIGHWAY -11 SUIT
LA QUINTA, CA 92253
LA QUINTA, CA 92253 v r
s
(760)567-2026 z
C
Llc. No.: 992255
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 992255
Dat -06 Contractor:@ JPn ✓J�7
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of.proving that
he or she did not build or improve for the purpose of sale.).
( ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044,.5usiness and Professions Code: The Contractors'
State License Law does not apply !10n owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's
WORKER'S COMPENSATON DECLARATION
I hereby affirm under penalty of perjury one of -the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3706 of the Labor Code, for the performance
of the work for which this permit is issued.
1 have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carri r: PoIicy 'umber:_
�i W (`certify that in the performance of the work for which this permit is issued, I
sha not employ any person in any manner so 3s to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply, with those provisions.
Dat —' _ ApplicantP�
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOP IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on thi! application.
1. Each person upon whose behalf this application is made, each person at. whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of ssuance of such permit, or cessation of
work for 180 days will subject permit to cancel ation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordi lances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above-
mentioned property for inspection purposes.
Datg—( ~ [ Signature (Applicant or Agent):00&
•� ,
gmmm
�='G''s: s �,.t,-'�•'k`�K..>-*.a'�'�F'vaW+.r�.:.- `�'.Y�"' _ �.� '� � '�Y�"sF a' '-%'.a"4 X�:`i�;kkW" , ��.y�` r �_ �Y i. X53 k ..}v� ��FY+>�i� +'+^b„ ��y'�i4,�� � ��;�+<�. �'"#t .r-'�`; v��'�S'�"�.'}f.. err
t�DESCRIPTIUN°:, ,, X?"sACCOUNT? QTYzG^ „AMOUNT AIDxPAIDpATEp
`v`_>a??'syi"tb"'`tl.'k+;•;6�:'_"r'?z.'r,.>7"T-"'h.T{:C?3'4.u+i.�"+1�`,Y��'.��+'�»lt�.'C:,�a:?�5iw'�;+ . :..?�i.�'+»�'t'"JIk".h`te.C+: '�'5;:..'l',F"�ir��C�'+ctc`'SLi: Ly'.i'tkC�`5>�`: {%`.'.:Y.iiF t ��r��"s`sti+..`a'rri�a'.�?.f�.J.�,� `i^-t7'�i€. *�'.,i'`�..'Ei'a u..w!a.
ADDITION, EA ADDITIONAL500 SF 101-0000-42400
0 $62.36 $0.00
-zW gH x
�RECEIP�T�#�x
PA DB�r».��.asMf 0EE
rsa s e r xs
BECK
*€,.��,�,-ria
; � 'x 'DESCRIPTION � 2 � ACCOUNT " a n
QTY .,
.s9_0.�*t?� �,
, M, _NM JPAID z PAID DATE's
MM
ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600
0
$17.40 $0.00
-MIMI��n X.�'. - $g'��3c^"'7rds:'ta+.�' an"i '; .: ~ '� 'FN.?*�:+"`3d'r..'..,�." t;`
y� 4 PAID BYr � v ° � ETHOtD r
l.-rn`Yz.r�., i��,.k>.
. `Lk>...:.Z, . �1„Fv:y",{ �+.k�,� .c �'i'kvTfJ0.t:, ". sS'Y,+�:i,1.'e+fiC
§4ffl EI E K #�� z Cl`Tx kBY u
c�L '',uX�?:=...13 't.,' r '. ,�:�?':r'� f,. .r`'j yE'` �.,�y}y
�iSPrTI € 0ME 4`>ACCxOUN�5,3QN�
Y:;,tl
Y:""f4 =4,x•.1. ,. .'rv' s>�F a. v$�`Fg*=r''iz.�S'ry i+Kvit
aAMOUNT�t .PAIPAIDkOAT:En
ADDITION, FIRST 100 SF 101-0000-42400
0.
$120.83 .5 $0.00
4E�'�' .y i4. 4`s•`YS""r '.'�-P4C'4�s t'ijfP iF+4'4 .. g "�.�k`-ii4`j.y,.'&
PAIO;BY METHOD�
°.
.. fit, r'�`r T('ICS4W -W �' ��''...�>nQ.it"•�''F�W;`N%aD4'T.�
RECEIRT #CHECK"#�CLTD
ir.Dz`sZY' "" ,g >.&t
t':�,s
r UESCRIPTIONQTY�sMQUNTu��P�DaTEx,
;' F'' a. ti �, i ' `' •' '�?:
ADDITION, FIRST 100 SF PC 101-0000-42600
0
$171.14 $0.00'
�� `Y"•7 . '�v 'k"z ��t`"��°F��'£, `' •+Y..,�'� ..=i.�['.+�t�.• .. �� ,S''l •^. _'��'t5.'';F:c�� 1`;i�K'�.,
mPAID,BY '. s METHODSp�#RECE�IPT#CHECK
i� I �..'Y 1�%/jS'rAY:`J.i+'.',(.Y X :'i`E ti��x&.''�'''r_'�' fi�,Si E•' h�ri'v. v.
#�CLTDhBY
Total Paid forADDITION: $371.73 $0.00 -
S'SYLv .: YS fil+�.,•z :H•3'.z'^',n. ' b .i ��
DESCRIPTION ', , ,��•�
DE
'�
" •�' ... R`N-°fY"hi'.*.... .. : 8:1� ..I
ACCOUNT
g.Y•.•SX °4..�.
yup �4 .tY:�`ri%'«t'r�''T
AMOUNT
:�- '�''�':S' *iH a
s PAID.,,:
:41. afi.ti
=PAID DAT£
HOURLY PLAN.CHECK -YES
101-0000-42600
1.75
$122.50
$0.00.
�_.asU�PAIDB�Y� �'�MNOIN
xgm'REEIPT#s?a�
C`TD B
Total Paid forBLDG CITY STAFF - PER'HOUR $122.50• $0.00
FCssk7'i4Y�"^ .tARf' ==!s`�`.i"`i=Y•,ixBfd` 3t�+iki} ^Fc. ;;n
DES CRIPTION, �y�; � � M R
a: �r _ { .:?w'S''r`S"....'.+ ._ q �. :
Man
ACCOUNT
ify"G-`s>,' ' :'X ifi'd.°4:R:.5y.7tzs
QN� ;. AMOUNT
f;�,
.,2_ .,.,. P � � s
t _.'•z'" .'?ki$
A D E
BSAS SB1473 FEE
101-0000-20306
0 $4.00
$0.00
OWN
�ti.✓ali�.rz�_�1..NI� ?_ ..
.... MEET OBD ''
�
`'RECEI T #
CHECK #�
x.s 332iss
CCTO Y
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $4.00 $0.00
i:. �y •�j r' ¢§ -r��s
5 I � DESCRIPTION , �r�
'?.., > ng -pj
ACCOUNT
QTY
' . ...
��ANIOUNT
PAIf)
PAID DATE
RESIDENTIAL, FIRST 1,000S1`
101-0000-42403
0
$145.03
$0.00
s'+i ..
��PAID BYs i�,:.:��
,.:METHO�D�13'
e
gir
��REEPT70 'x
r g„.: 'z ^sx�t, ga '
CK#CLTDBY
3 ' 7+z
MIN,.;ti"y :"{''''';.c::?'tni4+raF..Jv">p" , r ''...."''
a.•.+n5'�rSi�.'e�i.:Us.+,e..;;t',...FF.°.Xrs,•i�z��s'" "=11
DESCRIPTION' s
.q,. ,j,t;:`+k'sF�.'3'4'"k w_"viyvg•.' ' S�
Al ACCOUNT .^
fcs+Fr .,'">,✓r*. i3. ��..
,'' r.
QT,Y
':;: >s�•;�33�
.iiv°Cr i+. `t;,,t,,'r
�AMOIJNTPAID`r
yv
�Yw";;�£'.;4�6�afi+.,+:"+'�:§�
• '�{ ±w'.w',rk.+`:�`C'¢3::.
a
f�3*..:' �' yrv,"fi'.�:
1.ut?$,..,_ay.'i'.`�t'����C.
PAID'DATE:
.h.d>.��`3:?Ys�C:"�.+�k
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$0.00
xr "" `.•�,�"'4S'�S°t�"w�"
n'>P.,i4tDTBYk�
0.1 11 �.. --;x .: ` ' � �����
vYY t. !" Std`. `':dGea'.tfi. k....:..+.:A.s:`�.
+ �-���2sy^a� -���
METHOD`
.x..`5''�.' U'.
��� � 4 > ��Z
Yti �'' S�'z.+S¢'.�'o..xr`.� h� 3y
RECEIPTS#.�
Yfe!.'9S'v�':f:X'"'.. i}.e..yn.
� �' � �
CHHECK;#
a , � .�
r�r' i.c"�-w':.�` :.uEL"}5. i,r^...,:.
{..
� CLTD BYE'
ti J.%�"3M.
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
,,...,. k2."ys,i..:...
.. .DESCRIPTION" ;-
'-:`;`"'wf.>3_:b:a,:k'z'c�Y,.:;-3.'z'�t^-•a's:_.:_�....:.. .....-r'�.;t?;.n-;:i`i.�:K
-..�.'i1iN+".rt.. hNE+";';I*k��,?.:k
"A000U,NT°.,',QTY•
N.'c�,:,'xi.+`.ac.s,c.,z."xA"..�`�:::4.`�„t�,'<.3�$s'&y
, AMOUNTS'
11,0
n
PAID;
PA DFD'ATE
.3k Ai^
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$0.00
zsg '>.'';.,£4' _°g$`;a"%k°"ate'":
A F4AIDBY����
°;..,'>:a:ri,-Na�.�'''.;.. _.�..�F<+5
; METHOD.,.�RECEIPT#CHECK#wCL�T4DBYf
!?. ha�':'.i3.�Yh<sc::
•:3§x:."i'.' "''1,,,.
�M^"'''a+'e".'c t
�Srer11,111
WEEMS
7
,COUNT
WINE
, 'm
"un , AMOUN TO, I
N, i. Mrj
ED)
wo mMz sm",
ow,
APPIMCE.REPAIR/ALTERATION PC
101-0000-42600
0 $4.83
$0.00
WA'
mm R
wz
All 1,
4,Sf n0ZIM `�T'X"&%%
T
0
M `,CHECW'#-
EMST."m
C "IT *BIVE
NO, !
Ot Ri
'Total Paid forMECHANICAL: $16.92 $0.00
g
N N 11
gm
A IMi
PATIO COVER, STD, OPEN
101-000042404
0
$97.17
$0.00
mw -W,
SIR,
Milli offi^", 0moo ME
101.
)T
IRWIN
m
DESCRIPTION" aY."
AMOUNTSR
50 r. IRE"
'-T
VAlbbA-ft
PATIO..COVER, STD, OPEN PC
101-0000-42600
0
$95.72
0.00
PAI
I Em P��
1"WIr In
-T
vm
ME
NO
I IN
'k -V !T %4"
'm
Total Paid for PATIO COVER COVERED PORCH LATTICE $192.89 $0.00
IBM" :(.is'.
x
.11-111 RE
IN 'XV v
PAID DATE;
. =V=PVWN�
FIXTURE/TRAP
101-0000-42401
0
$12.09
$0.00
W
01'. METHOD
M,01
11 ON 111, N 11,116
01"M MHE6 r1f,
X al
OEM I
f CL T D, 9
I E �
ME
0 TM
"WIt
4gg.p
j4,g,,1AkCOUNTT-,,k,q ffing
0
'i-&�MOUNUNN-M,
"BRAURIN' g
:`Asn�rTtwEl i.
'ID;,"D
jfA
FIXTURE/TRAP PC
101-0000-42600
0 $12.69-
$0.00
BYLids�THO
R -ASRNOm
R
g
g
MAID
."mIAf.t=IPw-f9mW, n oul
t,HECK
J-55
Total Paid forPLUMBING FEES: $24.18 $0.00
ffl"Z
Mq
PAIffi4
Ic
REMODEL, EA ADDITIONAL 500 SF
101-0000-42406
0
$21.75
$0.00
_0 )-c'm -4g, Mr
PAID5
011 W
56 ep
smommmmmm
5.
RECEIPT �5'
:W-6
WT
I'M W
WE
SAIN,
Ya>�ILW� WEN �,MiF
"Ell
p - ml
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42606
0
$17 . .40
$0.00
y R
W", ' I e!
'M IF, T,� H. 0 !D $,,
Iffi E PRO`
J,t
�T
0m, I
M
f EIN
REMODEL, FIRST 100 SF
.101-00010-42400
0
$49.31
$0.00
ZEN 1-111111" 1111 �Mllffi
;,WROMMONST4
�gg- wggw�g
EYE M M ET
Rl� NMI,
El
"S
Will MINE
.-§�MOUNT
I I Z�7,nW -10
m
x
`PRIMTE,,
REMODEL, FIRST 500 SF PC
10110000-42600
0
$134.88
$0.00.
PAIDzBY
I " 'm
, I - "
" ME
H,, A Vg�
Ri .sib''' V FAA
N., m - E i, `5 110"',N�h
t PT
IN 07.z- I-,
lf� R';�A� 7x� !6-t
CHECK LZ A
CTD Blf
Total Paid forREMODEL: $223.34 $0.00
M�N, WE'
)UNT
3c��PAID
SMI -RESIDENTIAL
1-20308
$10.41
-$0.00
Description: KOSMOS / 255 ADDITION FAMILY ROOM
Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED
Applied: 8/7/2015 SKH
Approved: 8/26/2015 JJO
Parcel No: 658220005 Site Address: 49215 VISTA VENTURA LA QUINTA,CA 92253
Subdivision: TR 25237 Block: Lot: 50
Issued:
Lot Scl Ft: 0 Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $80,090.40 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
8/18/2015
Details: REM / ADD, CONVERT 288 SQ. FT. OF PATIO TO NEW FAMILY ROOM AND REMODEL KITCHEN AREA. RELOCATE EXISTING BBQ ADD
NEW SINK TO FAMILY ROOM. 2013 CALIFORNIA BUILDING CODES.
..j Applied to Approved
Printed: Tuesday, September 01, 2015 8:19:32 AM 1 of 4 r
SYSTf.•ti1S
NOTES
CHRONOLOGY TYPE
STAFF NAME
CHRONOLOGY
ACTION DATE
COMPLETION DATE
PLAN CHECK COMMENTS
FROM CONSULTANT
RECEIVED
PHILIP JUAREZ
8/18/2015
8/18/2015
RECIEVED ; APPROVED PER YOUNG
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
8/20/2015
8/20/2015
PLAN CHECK SUBMITTAL
RECEIVED
STEPHANIE KHATAMI
8/7/2015
8/7/2015
RESUBMITTAL
PHILIP JUAREZ
8/24/2015
8/24/2015
11 SAID OK PUT ON WEEK 1.I51 NUN 51 RUIN UKAL UIYLY.
SENT TO PLAN CHECK
CONSULTANT
STEPHANIE KHATAMI
8/7/2015
8/7/2015
CONDITIONS
Printed: Tuesday, September 01, 2015 8:19:32 AM 1 of 4 r
SYSTf.•ti1S
Printed: Tuesday, September 01, 2015 8:19:32 AM 2 of 4 RwYSTr:MS
FAX
EMAIL '
NAME TYPE
NAME
ADDRESSI
CONTACTS
CITY
STATE
21P
PHONE
APPLICANT
GREGORY JOHNSON CORP DBA G
JOH
78365 HIGHWAY 111
SUITE 177
LA QUINTA
CA
92253
CONTRACTOR
GREGORY JOHNSON CORP DBA G
JOH
78365 HIGHWAY 111
SUITE 177
LA QUINTA
CA
92253
DESCRIPTION
ACCOUNT
QTY
OWNER
GEORGE KOSMOS
601 UNION ST STE 3900
SEATTLE
WA
1 92253
PAID BY
BY
ADDITION, EA
Printed: Tuesday, September 01, 2015 8:19:32 AM 2 of 4 RwYSTr:MS
FINANCIAL••
•
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT#
CHECK #
METHOD
PAID BY
BY
ADDITION, EA
101-0000-42400
0
$62.36
$0.00
ADDITIONAL 500 SF
ADDITION, EA
101-0000-42600
0
$17.40
$0.00
ADDITIONAL 500 SF PC
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
ADDITION, FIRST 100 SF
101-0000-42600
0
$171.14
$0.00
PC
Total Paid forADDITION: $371.73 $0.00
HOURLY PLAN CHECK -
101-0000-42600
T1.75
F$122.SO
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR: $122.50 $0.00
BSAS S61473 FEE
1 101-0000-20306
1 0
$4.00
$0.00
total Paid for BUILDING STANDARDS ADMINISTRATION $4.00 $0.00
BSA:
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$0.00
1,000SF
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$0.00
1,000SF, PC
Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00
Printed: Tuesday, September 01, 2015 8:19:32 AM 2 of 4 RwYSTr:MS
INSPECTIONS
SEQID INSPECTICIN TYPE INSPECTOR SCHEDULED COMPLETED RESULT F' REMARKS7 NOTES
DATE DATE
Printed: Tuesday, September 01, 2015 8:19:32 AM 3 of 4 ,
SYSTEMS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
APPLIANCE
101-0000-42402
0
$12.09
$0.00
REPAIR/ALTERATION
APPLIANCE101-0000-42600
0
$4.83
$0.00
REPAIR/ALTERATION PC
Total Paid forMECHANICAL: $16.92 $0.00
PATIO COVER, STD,
101-0000-42404
0
$97.17
$0.00
OPEN
PATIO COVER, STD,
101-0000-42600
0
$95.72
$0.00
OPEN PC
Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00
FIXTURE/TRAP
101-0000-42401
0
$12.09
1 $0.00
FIXTURE/TRAP PC
101-0000-42600
0
$12.09
$0.00
Total Paid for PLUMBING FEES: $24.18 $0.00
REMODEL, EA
101-0000-42400
0
$21.75
$0.00
ADDITIONAL 500 SF
REMODEL, EA
101-0000-42600
0
$17.40
$0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$0.00
PC
Total Paid for REMODEL: $223.34 $0.00
SIVII - KtSiUENTIAL
101-8880.20508
1 0
$10.41
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $10.41 $0.00
TOTALS:00
INSPECTIONS
SEQID INSPECTICIN TYPE INSPECTOR SCHEDULED COMPLETED RESULT F' REMARKS7 NOTES
DATE DATE
Printed: Tuesday, September 01, 2015 8:19:32 AM 3 of 4 ,
SYSTEMS
FINAL" I BLD I I I I I
Printed: Tuesday, September 01, 2015 8:19:32 AM 4 of 4 J
sysTrnns
PARENT
PROJECTS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
REVIEWS
STATUS REMARKS
NOTES
Attachment Type
CREATED
OWNER
DESCRIPTION
DATE
SUBDIR ETRAKIT ENABLED
NON-STRUCTURAL -
JIM JOHNSON
8/7/2015
8/21/2015
8/20/2015
REVISIONS REQUIRED
0
DOC
2 WK
JIM JOHNSON
VENTURA.docx
VENTURA.docx
YOUNG
8/7/2015
8/21/2015
8/18/2015
READY FOR APPROVAL
8/26/2015
JIM JOHNSON
STRUCTURAL - 2 WK
ENGINEERING
1ST REVIEW -
NON-STRUCTURAL -
JIM JOHNSON
8/24/2015
8/31/2015
8/26/2015
APPROVED
STRUCTURAL
BRES 2015-0305
1 WK
0
TRANSMITTAL
(ist).pdf
Printed: Tuesday, September 01, 2015 8:19:32 AM 4 of 4 J
sysTrnns
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATFINAME
SUBDIR ETRAKIT ENABLED
49-215 VISTA
49-215 VISTA
0
DOC
8/20/2015
JIM JOHNSON
VENTURA.docx
VENTURA.docx
49-215 VISTA
49-215 VISTA
0
DOC
8/26/2015
JIM JOHNSON
VENTURA.pdf
VENTURA.pdf
1ST REVIEW -
NEW CITY TRANSMITTAL
DOC
8/18/2015
KATHRYN SAMUELS
STRUCTURAL
BRES 2015-0305
0
TRANSMITTAL
(ist).pdf
Printed: Tuesday, September 01, 2015 8:19:32 AM 4 of 4 J
sysTrnns
Bin #
City of La Quinta
Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address; A' .V ILL
Owner's Name: C �(J
A. P. Number:
Address: (.-f 6j
Legal Description:
City, ST, Zip:
Contractor:
U
TeleP h0 ne:
Address:
l e %
Project Description:
City, ST, Zip: L�
Te 7
le hone:
P 6d 6
State Lic. # :
City Lic.
Arch., Engr., Designer:
Address:
City., ST, Zip:
Telephone:
Construction n TYP e• V O ccs ancY:
Lic. #:
Add'n trReState
'
Project tyPa (circle one): New air Demo
Name of Contact Person:
Sq. Ft.: 'Z
# Stories:
# Units: I
Telephone # of Contact Person: �;b�—
Estimated Value of Project: crt)
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, re for corrections
�(j
Plan Check D_posit
Truss Cales.
Called Contac on
g
Plan Check Balance.
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
god Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN I1OUSE:-
'"' Review, ready for corrections/issue
Developer InVact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District 4� �o
47950 Dune Palms Road ¢ BERMUDA DUNES
RANCHO MIRAGE tj
Date 8126115 La Quinta, CA 92253 INDIANWELLS
PALMDESERT
y
No. 31918 (760) 771-8515 `�J'�QINDIO LA QUINTA y7�
O
Owner Kosmos
APN # 658-220-005
Address 49215 Vista Ventura
Jurisdiction La Q jinta
City La Quinta Zip
Permit #
Tract #
No. of Units 1
Type Residential Addition
Lot # No. Street
S.F.
Lot # No. Street S.F.
Unit 1 49215 Vista Ventura
288 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments Convert Patio to Family Room
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiosfivalkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 288 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Greg Johnson Check No.
Bank Name/Recipient of Certificate Telephone 760-567-2026
Funding Exempt
By Dr. Gary Rutherford
Superintendent
Fee collected /ex46��yOn IIVf�y Payment Recd
—� :.Jiver/Under -
Signature
NOTICE: Pursuant to Government Code SectZl '66020(d)(1), this qlI serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this proje:t is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) be-lalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting .
Associa°
Desert Resort Management
August 6, 2015
George C. & Kathleen Kosmos
49215 Vista Ventura
La Quinta, CA 92253
RE: Mountain Estates HOA — 49215 Vista Ventura
Kitchen & Family Room Remodel
Dear Mr. & Mrs. Kosmos:
Your architectural request to remodel the kitchen and family room, which includes expanding
into the patio space, at the residence listed above has been approved by the Board of Directors
with the following condition:
Ensure any and all construction adheres to setbacks outlined in the Mountain Estates
architectural guidelines (10 feet).
Please note that this approval is valid for ninety (90) days from the date of this letter. If the
modification will not be completed within that timeframe, you will need to re -apply for
architectural approval.
We trust that only licensed, insured contractors will be performing the work. Please be
reminded that any damage to the common area due to construction should be repaired in a
timely manner.
Thank you for your cooperation in filing for architectural approval. If you have any questions or
need further assistance, please feel free to contact me at 760.346.1161.
Sincerely,
I�fiJ�
Mark Dodge, CEO
Community Association Manager
On Behalf of the Board of Directors
Mountain Estates Homeowners Association
CC: Homeowner File
YOUNG
v ENGINEERING
1 E R v. C E
Letter of Transmittal
To: City of La Quinta Today's Date:
8-18-15
78-495 Calle Tampico City Due Date:
8-21-15
La Quinta, CA 92253 Project Address: .49125 Vista Ventura
Attn: Kay Plan Check M
BRES 2015-0305
Submittal: ® 1st
❑ 4th
❑ 2nd
❑ 5th
❑ 3rd
❑ Other:
We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS)
❑ Your Pickup
Includes: # Of Descriptions: Includes: # Of
Descriptions:
Copies:
Copies:
® 1 Structural Plans
❑
Revised Structural Plans
® 1 Structural Calculations
❑
Revised Struct. Calcs
❑ Truss Calculations Floor
❑
Revised Truss
and Roof
❑ Soils Report
❑
Revised Soils Report
❑ Structural Comment List
❑
Approved Structural Plans
❑ Redlined Structural Plans
❑
Approved Structural Calcs
❑ Redlined Structural Calcs
❑
Approved Truss Calcs
❑ Redlined Truss Calcs
❑
Approved Soils Report
❑ Redlined Soils Reports
❑
Other:
Comments: Structural content is approvable.
If you have any questions, please call.
Time = 1.75 HR
W
This Material Sent for:
;z Q_
❑ Your Files I... CIIJ
Per Your Request
❑ �/ 00 Your Review
zbt Approval
❑ Checking 1O
At the request
of:
Other: ❑ J Q ,.
By: Kathryn Samuels
�O
Palm Desert Office: ® (760) 772-5107
Other: ❑
CITY. OF LA QUINTA .SUB&JONTRACTOR LIST _
JOB ADDRESS4��i5 V�S'r
PERMIT. NUMBER $ �S��S-0�O�/VNER <<-�►�tc BUILDE13
This form shall be posted on the job with the Building
Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance.
of .building permit. For each applicable trade, all information requested below must be completed by applicant. "On -File" is not a.n acceptable response.
Tcade.L..Clas sification.................................Contras:tor.......................
.......................... .
...:......................State..Contractor..s:License..................:.....................::.
:..
:«.::.;:;::•;.;:.... w.orkers..Co.m .ensation In ................................Y................................................
rt Business::License
Company Name
Classification-
License Number
ExP.Com Date
Carrier Name -
Policy
Exp. Date
License. Number
Exp. Date
.9 AB C -8
xxxxxx
xx x x
e. . State CalCom)
Format Varies)
xx/xx xx)
x xxx)
(xxlxx /xx )
R:.,1'.IW.........3EA-`
/!J ' .
CQ.NC.RETE lC: 8.) » < ?::`>
G v1�J G
�1.
/
��ii'L
�i-�V_ �(�
to 31
I t
v
STRU.C..:...STEEL:.4C.;5:.;:�<:;;;;;
/V
MAS;O
PLU PIN
�li�a
:LATH :PLgS:TER (G-�5.): :
ELECTRICAL:::(C:<�<01.:<:>::s:>::>::»»
v.�
L —.lO
3� 2-^
"y►.
�p��
�^`7 l✓
WF
2'' _
- 6
I
SHEE.T<METAL:>(C-:43:)`.`#
.
FLOORING' C. i5
GLAZING'
.::: ;:I.;:.;.;:.:
i
aNSU:LATION 'C-2)'«< <? `i
SE.INAGF;DISP:»f.C'=4'.2):<?
PA1NTING`.>{C`.33)'::>:' >a?>>'
CERAMIC. TILE (C.:=54.);
:.:FENC,I,NG;aC:::1;3) ::`; >:< s`.;':
DF_ IN X n
JCM Inspections
IIIJ t 39725 Garand Lane Suite F
SEP 4 12015 Palm Desert, CA 92211
INSPECTIONS Phone: 760-275-5020 - Fax: 760-327-8907
INSPECTIONS
CITY OF LA QUINEpOXY INSPECTION REPORT
Date:�� _
Project Name:
Project No: 15-91
Kosmos Residence @ The Enclave Mountain Estates
Project Address:
City:
49215 Vista Ventura
La Quinta, CA
Client: Sub -Contractor:
Owner
General Contractor: Architect: Structural Encineer:
Greg Johnson Construction RA
Anchor Bolts Ej.,Rebar
Z IBC
Title 24
Epoxy Type: t1oc!ti
�
Other:
R C
Epoxy Shelf Life:
Unresolved Items:
-31
Hole Cleaning Method(s):q,\,o.s C (r,c, t-� C>c u<`r.� / t.y�nr�
r.
❑ None
see Below
Description of Work Inspected: _
,
Ql' } 4 n O
l� ' t
nPAD
, 1
P It
U
4
a nn""
- L t C_
=\-\.a
\-
PD e
S
�.
Work complies with written approval from Structural Engineer and ICC Evaluation Report #
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector: Ja k C. CC rtification No: 0842216-49
Contractor's Representative:
Millin
).C,
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page T of
n
BUILDING ENERGY ANALYSIS REPORT
AIG 2.4 �ui5
CITY Cf L� QUi;\1TA
COMMUNITY DE\,ELOPMF-NT
PROJECT:
Kosmos Residence Addition
49215 Vista Ventura
La Quinta, CA 92253
Project Designer:
G. Johnson Construction
78-365 Highway 111, Suite 177
La Quinta, CA 92253
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm DesIONSTFkJCTION
11
(760)F LA QUINTA
G & SAFETY DEPT,
PROVED
DATE 13 Z ( I BY
Job Number:
Date:
8/20/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
6.7 by EnergySoft User
) V L
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 13
Form MF -1 R Mandatory Measures Summary 15
HVAC System Heating and Cooling Loads Summary 19
Room Load Summary 20
EnergyPro 6.7 by EnergySoft Job Number. ID: User Number: 6712
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CF1 R -PRF -01-E
Page 1 of 10
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Kosmos
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 49215 Vista Ventura
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 5856
15
Number of Zones 2
16
Slab Area (ft2) 5856
17
Number of Stories 1
18
Addition Cond. Floor Area 288
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 288
21
Glazing Percentage (%) 31.0%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-20 15:58:30
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.95
5.26
-0.31
-6.3%
Space Cooling
261.97
263.27
-1.30
-0.5%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
5.87
4.23
1.64
27.9%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
272.79
272.76
0.03
0.0%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-20 15:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Calculation Description: Title 24 Analysis Input File Name: Kosmos Res. Addn-Lucy-15.xm1
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cathedral Ceiling
• Window overhangs and/or fins
CF1 R -PRF -01-E
Page 2of10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer' analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
— None —
Cooling System Verifications:
—VANone —
HC Distribution System Verifications:
— None —
Domestic Hot Water System Verifications:
—None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 308.63 308.60 0.03 0.0%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Kosmos
5856
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Exist Res
Conditioned
HVAC 1-41
5568
9
DHW Sys 1
Addition
Conditioned
HVAC 1-41
288
9
1DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-07082015-744 Report Generated at: 2015-08-20 15:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CF1 R -PRF -01-E
Page 3 of 10
OPAQUE SURFACES
01
02
03
04
05
06
06
07
08
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (f:2)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
N Wall
Exist Res
R-19 Wall (W.19.2x6.16)
0
225
130
55.2
90
Existing
No
NE Wall
Exist Res
R-19 Wall (W.19.2x6.16)
45
Right
920
217.6
90
Existing
No
E Wall
Exist Res
R-19 Wall (W.19.2x6.16)
90
315
130
71.6
90
Existing
No
SE Wall
Exist Res
R-19 Wall (W.19.2x6.16)
135
Front
1100
307.8
90
Existing
No
SW Wall
Exist Res
R-19 Wall (W.19.2x6.16)
225
Left
830
313.4
90
Existing
No
W Wall
Exist Res
R-19 Wall (W.19.2x6.16)
270
135
220
133.2
90
Existing
No
NW Wall
Exist Res
R-19 Wall (W.19.24.16)
315
Back
920
458
90
Existing
No
Roof 2
Exist Res
R-30 Roof(R.30.2x12.16)
5471
Existing
No
NE Wall 2
Addition
R-21 Wall (W21.2x6.16)
45
Right
30
90
New
N/A
SE Wall 2
Addition
R-21 Wall (W.21.24.16)
135
Front
160
27
90
New
N/A
SW Wall 2
Addition
R-21 Wall (W.21.2x6.16)
225
Left
176
90
New
N/A
NW Wall 2
Addition
R-21 Wall (W.21.24.16)
315
Back
240
160.056
90
New
N/A
Roof 3
Addition
R-38 Roof Attic
288
New
N/A
OPAQUE SURFACES—Cathedral Ceilings
01
02
03
04
05
06
06
07
08
09
10
11
12
13
Roof Reflectance
Roof Emittance
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic Exist Res
Attic RoofExist Res
Ventilated
Roof
0.1
Framin
No
Verified
Existi
ng
No
Attic Addition
Orientatio
Area
Skylight
Roof Rise
Roof
Roof
Reflectan
Roof
g
Statu
Existing
Name
Zone
Type
n
(ft)
Area (ft2)
(x in 12)
Pitch
Tilt(deg)
ce
Emittance
Factor
s
Condifion
R-30
Existin
Roof
Exist Res
Roof(R.30.2x12.16
- specify -
97.1
8
3
0.25
14.04
0.1
0.85
0.1
No
)1
9
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic Exist Res
Attic RoofExist Res
Ventilated
3
0.1
0.85
No
No
Existi
ng
No
Attic Addition
Attic RoofAddition
Ventilated
0
0.1
0.85
Yes
No
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-2015:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Input File Name: Kosmos Res. Addn-Lucy-15.xml
CF1 R -PRF -01-E
Page 4 of 10
WINDOWS
01
02
03 04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Multiplie
Width(ft) Height (ft) r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Ex. Glazing -Z
N Wall (- specify -0)
- - 1
25.2
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -6
N Wall (- specify -0)
- - 1
30.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing-[
NE Wall (Right -45)
- - 1
10.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -H
NE Wall (Right -45)
- - 1
16.6
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -F
NE Wall (Right -45)
- - 1
30.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -17
NE Wall (Right -45)
- - 1
45.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -D
NE Wall (Right -45)
- - 1
80.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -C
NE Wall (Right -45)
- - 1
36.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -F 2
E Wall (- specify -90)
- - 1
30.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -Y
E Wall (- specify -90)
- - 1
41.6
0.79
0.59
Insect Screen (default)
Existing
No
NEW
SE Wall (Front -135)
- - 1
20.1
0.51
0.30
Insect Screen (default)
New
N/A
Ex. Glazing -E
SE Wall (Front -135)
- - 1
36.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -13
SE Wall (Front -135)
- - 1
24.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -A
SE Wall (Front -135)
- - 1
22.5
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -2
SE Wall (Front -135)
- - 1
36.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -A 2
SE Wall (Front -135)
- - 1
22.5
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -X
SE Wall (Front -135)
- - 1
115.2
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -W
SE Wall (Front -135)
- - 1
31.5
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -U
SW Wall (Left -225)
- - 1
64.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -18
SW Wall (Left -225)
- - 1
48.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -S
SW Wall (Left -225)
- - 1
42.4
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -18 2
SW Wall (Left -225)
- - 1
48.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -5-R
SW Wall (Left -225)
- - 1
24.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -P -R
SW Wall (Left -225)
- - 1
32.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -L
SW Wall (Left -225)
- - 1
55.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -Q -R
W Wall (- specify -270)
- - 1
44.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -K
W Wall (- specify -270)
- - 1
40.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -N
W Wall (- specify -270)
- - 1
24.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -J
W Wall (- specify -270)
- - 1
25.2
0.79
0.59
Insect Screen (default)
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-2015:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CFI R -PRF -01-E
Page 5of10
Ex. Glazing -T
NW Wall (Back -315)
- - 1
32.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -R
NW Wall (Back -315)
- - 1
44.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -P -R 2
NW Wall (Back -315)
- - 1
32.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -5-R 2
NW Wall (Back -315)
- - 1
24.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -0
NW Wall (Back -315)
- - 1
35.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -M
NW Wall (Back -315)
- - 1
120.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -20
NW Wall (Back -315)
- - 1
90.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -19
NW Wall (Back -315)
-- - 1
63.0
0.79
0.59
Insect Screen (default)
Existing
No
Ex. Glazing -G
NW Wall (Back -315)
- - 1
18.0
0.80
0.39
Insect Screen (default)
Existing
No
Skylight
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 2
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 3
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 4
Roof (- specify -270)
- - 1
9.0
1.30
0.60
None
Existing
No
Skylight 5
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 6
Roof (- specify -270)
- - 1
4.0
1.30
0.60
None
Existing
No
Skylight 7
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 8
Roof (- specify -270)
- - 1
4.0
1.30
0.60
None
Existing
No
Skylight 9
Roof (- specify -270)
- - 1
4.0
1.30
0.60
None
Existing
No
Skylight 10
Roof (- specify -270)
- - 1
4.0
1.30
0.60
None
Existing
No
Skylight 11
Roof (- specify -270)
- - 1
4.0
1.30
0.60
None
Existing
No
Skylight 12
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 13
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
Skylight 14
Roof (- specify -270)
- - 1
4.0
1.30
0.60
None
Existing
No
Skylight 15
Roof (- specify -270)
- - 1
8.0
1.30
0.60
None
Existing
No
New Window
NW Wall 2 (Back -315)
18.0 9.0 0.988
160.1
0.52
0.32
1 Insect Screen (default)
New
N/A
DOORS
01 02
03 04 05 06
Name Side of Building
Area (ft) U -factor Status Verified Existing Condition
Door SE Wall 2
27.0 0.50 New No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744
HERS Provider:
Report Generated at: 2015-08-20 15:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CFI R -PRF -01-E
Page 6 of 10
OVERHANGS AND FINS
01
02 03 04 05 0607
08 09 10
11 12 13 14
05
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
New Window
18
0.1
18
18
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Cavity/ Frame: no insul. /2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic RoofExist Res
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-30 Roof(R.30.2x12.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 30
0.032
Over Floor Joists: R-20.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-30 / 2x4
• Roof Deck. Wood Siding/sheathing/decking
R-30 Roof(R.30.2xl2.16)1
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 30
0.046
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -19/2x6
• Exterior Finish: Wood
R-19 Wall (W. 1 9.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
0.069
Siding/sheathing/decking
• Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider:
Report Generated at: 2015-08-2015:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CF1 R -PRF -01-E
Page 7 of 10
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
Exist Res
5568
376
None
0.8
No
New
No
Slab -on -Grade
Addition
288
57
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
2
Annual
Altered
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
75
0.72 EF
75000-Btu/hr
0
0.03
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-2015:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Calculation Description: Title 24 Analysis Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CF1 R -PRF -01-E
Page 8 of 10
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Multi -speed
Heating System
Cooling System
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
Distribution
Fan
Floor Area
Location
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC 141
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
5856
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntdFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
N/A
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Air Distribution System 1 -hers -dist
N/A
I— —
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03 04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%) Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
I— —
I— —
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-2015:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kosmos Res. Addn-Lucy-15.xmi
CF1 R -PRF -01-E
Page 9 of 10
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider:
Report Generated at: 2015-08-20 15:58:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Kosmos Calculation Date/Time: 15:57, Thu, Aug 20, 2015
Calculation Description: Title 24 Analysis
Input File Name: Kosmos Res. Addn-Lucy-15.xm1
CF1 R -PRF -01-E
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: A J
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
8/20/2015
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
LZ-
City/StatePah Desert, CA 92211
Phone:
200-4780
(760)
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Greg Johnson
Company:
Date Signed:
G. Johnson Construction
Address:
License:
78-365 Highway 111, Suite 177
City/State/Zip:
Phone:
La Quinta, CA 92253
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-20 15:58:30
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Kosmos Residence Addition
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/20/2015
Project Address
49215 Vista Ventura La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,856
Addition
288
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Roof Wood Framed Attic
R 30
5,471
Existing
Wall Wood Framed
R 19
2,693
Existing
Slab Unheated Slab -on -Grade
- no insulation
5,856 Perim = 433'
New
Demising Wood Framed
R 13
352
New
Roof Wood Framed Attic
R38
288
New
Wall Wood Framed
R 21
419
New
Door Opaque Door
- no insulation
27
New
FENESTRATION
Orientation Area ft2
Total Area: 1,814 Glazing Percentage: 31.0%1New/Altered
U -Fac SHGC Overhang Sidefins
Average U -Factor: 0.52
Exterior Shades Status
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 9.0
1.300
0.60 none
none
None Existing
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 4.0
1.300
0.60 none
none
None Existing
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 4.0
1.300
0.60 none
none
None Existing
Skylight 4.0
1.300
0.60 none
none
None Existing
Skylight 4.0
1.300
0.60 none
none
None Existing
Skylight 4.0
1.300
0.60 none
none
None Existing
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 8.0
1.300
0.60 none
none
None Existing
Skylight 4.0
1.300
0.60 none
none
None Existing
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
4 Central Furnace
80% AFUE
Split Air Conditioner 12.0 SEER
Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
HVAC 1-4 Ducted
Ducted
Attic
4.2
Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
2 Small Storage Gas
75
0.72
All Pipes Ins
Altered
EnemyPro 6.7 by EnemySoft User Number: 6712
RunCode: 2015-08-20716:14:17
ID:
Pae 13 of 20
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Kosmos Residence Addition
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/20/2015
Project Address
49215 Vista Ventura La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,856
Addition
288
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
FENESTRATION
Orientation Area f 2
I Total Area: 1.814 Glazing Percentage: 31.0%1
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor: 0.52
Exterior Shades Status
Skylight 8.0
1.300
0.60 none
none
None Existing
Rear (N) 55.2
0.790
0.59 none
none
Bug Screen Existing
Right (NE) 217.6
0.790
0.59 none
none
Bug Screen Existing
Right (E) 71.6
0.790
0.59 none
none
Bug Screen Existing
Front (SE) 20.1
0.510
0.30 none
none
Bug Screen New
Front (SE) 287.7
0.790
0.59 none
none
Bug Screen Existing
Left (SK) 313.4
0.790
0.59 none
none
Bug Screen Existing
Left (Kq 133.2
0.790
0.59 none
none
Bug Screen Existing
Rear (NVt9 440.0
0.790
0.59 none
none
Bug Screen Existing
Rear (NVtq 18.0
0.800
0.39 none
none
Bug Screen Existing
Rear (NW) 160.0
0.520
0.32 18.0
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
Ene Pro6.7 by EnemySoft User Number: 6712
RunCode: 2015-08-20716:14:17
ID:
Pae 14 of 20
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance aDDroach used. Exceptions may annly. Review the respective rnde seclinn fnr mnro infnrmnlinn
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFI R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
§150.0(g)l:
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
§ I50.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ I50.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)1 l:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow>_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permiss_ble methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
. 2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)lE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ I50.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
'
functionality of a dimmer according to 110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages,- laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §150.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §150.0(k)9B or 150.0(k)9D
'110.9,
shall comply with the applicable requirements in §130.0, 130.2, '130.4, 140.7 and 141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, $130.2, § 130.4, § 140.7 and $141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§150.0(k)1 l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 § 130.0, § 130.1 ' 130.4 ' 140.6 and ' 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)I2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of $110.10 b through $110.10 e .
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10 b through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§I10.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Kosmos Residence Addition
Date
8/20/2015
System Name
HVAC 1-4
Floor Area
5,856
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
4
COIL
CFM
Total Room Loads 9,016
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 835
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem
89,000
144,273
6,223 2,971
111,453
Total Output Btuh
356,000
0
Output Btuhls ft
60.8
12.234
7,918
Cooling System
01
0
Output perSystem
57,800
30,721
10,507 835
40,060
Total Output Btuh
231,200
0
16,731
0
Total Output Tons
19.3
12,234
7,918
Total Output Btuhls ft
39.5
Total Output s ft/Ton
303.9
199,461
P167,350
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
8,000
Existing HVAC 183,204 26,704
356,000
Airflow cfm/s ft
1.37
Airflow cfm/Ton
415.2
Outside Air %
10.4%
Total Adjusted System Output 183,204 26,704
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK Aug 3 MI
356,000
Outside Air cfmis ft 0.14
Note: values above given at ARI conditions
F Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
10
Outside Air
835 cfm
71 OF
66 OF 108 OF 108 OF
Heating Coil Supply Fan
8,000 cfm 107 OF
ROOM In
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 81 /66°F 81 /66°F 60/58°F
Outside Air Ar
835 cfm Supply Fan Cooling Coil 61 / 59 OF
8,000 cfm
53.4% ROOM 11
77/65°F 76/64°F
EnergyPro 6.7 by EnergySoR
User Number: 6712 RunCode: 2015-08-20716:14:17 ID: Page 19 of 20
J
ROOM LOAD SUMMARY
6,223
2,971
111,453
Project Name
Kosmos Residence Addition
6,223
2,971
Date
8/20/2015
System Name
HVAC 1-4
Floor Area
5,856
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM Sensible Latent
CFM Sensible
Exist Res Ex. Residence
1 8,513 136,231 5,917
8,513 136,231 5,917
2,742 102,854
Addition DiningAddn
1 503 8,041 306
503 8,041 306
229 8,600
PAGE TOTAL
TOTAL *
*T
9,016 144,273
6,223
2,971
111,453
9,016 144,273
6,223
2,971
111,453
Lioi IIINUUCJ VCIIWGUUII R$lU IUI LUIIHI 5 JJVJJJb.
EnergyPro 6.7 by Ene Soft User Number: 6712 RunCode: 2015-08-20T16:14:17 ID: Page 20 of 20