Loading...
12-1471 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12 - 00001471 Property Address: 49170 VISTA VENTURA APN: 658-220-014- - - Application description: DWELLING - SINGLE FAMILY Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 388028 Applicant: Tiht 4 BUILDING & SAFETY DEPARTMENT i BUILDING PERMIT J-1 Owner: THE COTTEN FAMILY TRUST 17 CALLE ANGELITOS DETACHED SAN CLEMENTE, CA 92673 (949)230-5941 Architect or Engineer: Contractor: ARCHITECTURAL CONSTRU 20250 SW ACACIA ST, S NEWPORT BEACH CA 926 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/22/13 N MGM 13 APR 23 2015 (949)637-8520 Lic. No.: 920899 clTlroFLAfIUINTA (� FINANCE DEPT. V= ----------------------------- LICENSED CONTRACTOR'S DECLARATION I here y affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Sectio 70 0) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. � Licens Cla : B License No.: 920899 % Dat ti Contractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 9017881 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code,A shall forthwith ply with those provisions. Date Applicant: CA WARNIN : FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I ave read this application and state that the above information is correct. I agree to comply with all city and coun ordinances and state laws relating to building construction, and hereby authorize representatives ont f this c uy to enter upon the above-mentioned property for insplecti on Zpu1`pyoses. /Date Signature (Applicant or Agent):_ YY 1 ✓✓ 1 Application Number . . . . . 12-00001471 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/LONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 3.00 FIRE SPRINKLERS YES GARAGE SQ FTG 792.00 PATIO SQ FTG 1215.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 4303.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 1651.00 Plan Check Fee 1073.15 Issue Date . . . . Valuation . . . . 388028 Expiration Date . . 10/16/13 Qty Unit Charge Per Extension BASE FEE 639.50 289.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 1011.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee 196.45 Plan Check Fee 49.11 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/16/13 Qty Unit Charge Per Extension BASE FEE 15.00 4303.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 150.61 792.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 15.84 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/16/13 QLy unit charge Yer Extension ---------------------------------------------------------------------------- . BASE FEE 15.00 Permit . . . . . . MECHANICAL LQPERMIT Application Number . . . . . 12-00001471 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 116.50 Plan Check Fee 29.13 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/16/13 Qty Unit Charge -Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 237.00 Plan Check Fee 59.25 Issue Date . . . . Valuation 0 Expiration Date 10/16/13 Qty Unit Charge Per Extension BASE FEE 15.00 26.00 6.0000 EA PLB FIXTURE 156.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 12.00 .7500 EA PLB GAS PIPE >=5 9.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4303 SF SFD(INCLUDES 638 SF GUEST CASITA) 2010 CODES W/ FIRE SPRINKLERS. ARCHITECT: STANLEY R. BRADEN C9034 **PERMIT DOES NOT INCLUDE_BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, BBQ'S and DRIVEWAY APPROACH** -------------=-------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 470.07 BLDG STDS ADMIN (SB1473) 16.00 DIF COMMUNITY CENTERS -RES 129.00 DIF CIVIC CENTER - RES 942.0.0 1;1 BRGY REV1BW V'BB lU / ..il DIF FIRE PROTECTION -RES 433.00 DIF LIBRARIES - RES 344.00 MULTI -SPECIES (MSHCP) FEE 1254.00 DIF PARK MAINT FAC - RES 40.00 LQPERMIT Application Number . . . . . 12-00001471 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF PARKS/REC - RES 2048.00 STRONG MOTION (SMI) - RES 38.80 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary Charged Paid Credited Due Permit Fee Total 2215.95 .00 .00 2215.95 Plan Check Total 1210.64 1000.00 .00 210.64 Other Fee Total 10617.63 .00 .00 10617.63 Grand Total 14044.22 1000.00 .00 13044.22 LQPERMIT Building / 70 Address `� Oser -_ 3J U Mailing Address 17 1 P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO _41UW A QUINTA. CALIFORNIA 92253 & Classif.Y l ��� l Lic. # Designer 2 LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Lav; for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (8500). 0 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). 111, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for one hundred dollars (8100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST I/OCC. GRP. U_I A.P. Number &5b –� 22-0�T g T p—�01� q qq Legal Description Lor 34 25237 A5 Project Description ZONE: BY: Minimum Setback Distances: Front Setback frorn Center Line 16, Rear Setback from Rear Prop. Line Side Street Setback from Center Line 16Side Setback from Property Line FINAL DATE Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTO Date PINK = FINANCE Sq. Ft. 0415 Size No. f No. DIN. Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ IN 11111! jf 1 cute I TYTF Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. 000, co Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback frorn Center Line 16, Rear Setback from Rear Prop. Line Side Street Setback from Center Line 16Side Setback from Property Line FINAL DATE Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTO Date PINK = FINANCE Date 4/15/13 No. 31603 Owner The Cotten Family Trust Address 17 Calle Angelitos City San Clemente Zip 92673 Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units .� c� Q BERMUDA DUNES Cn RANCHO MIRAGE b � INDIAN WELLS ^-+ d. PALM DESERT t}� LA QUINTA PINDIO yeti a 658-220-014 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 49170 Vista Ventura 4303 Unit 6 Unit 2 Unit 7E I V/ E D Unit 3 Unit 8 Unit 4 Unit 9 APR 15 2013 Unit 5 Unit 10 Comments CITY Cir" LA QUINTA COMMUNM DEVELOPMENT At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.20 X 4,303 S.F. or $13,769.60 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Sunwest Bank - Brad Cotten Bank Name/Recipient of Certificate By Dr. Gary Rutherford Superintendent Fee collected Signature by Shem n Check No. 66010269 Telephone 949-230-5941 Funding Residential Payment Recd $13,769.60 Over/l!ndr ` NOTICE: Pursuant to Government Code Section 66020(d)(1), this w I serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date hich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting ' RECORDING REQUESTED BY: EQUITY TITLE COMPANY WHEN RECORDED, MAIL. TO: Bradley Thomas Cotten, Trustee CIO Western Reliance Funding 24422 Avenida De la Carlota Ste 180 Laguna Hills, CA 92653 APN: 658-220-014-0 TITLE ORDER NO.: OR1255903 - - -A47 nn/t LbL:Kuvv rw.. " - THIS SPACE FOR RECORDER'S USE ONLY GRANT DEED The undersigned Grantor(s) declare that the DOCUMENTARY TRANSFER TAX IS: $ 330.00 County conveyed, or XX computed on the full value of the interest of property thereon at the time of sale. —computed on the full value less the value of liens or the following reason Wedged, remaining OR transfer is EXEMPT from to FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Dollar Varden and Debra Sue Varden Thomas Cotten and Julie Anne Cotten, Trustees of The Cotten Family Trust u/dlt dated HEREBY GRANT(S) to Bradley February 27, 2002 County of Riverside, State of California, described as: All that real property situated in the City of La Quia;A' ATTACHED HERETO & MADE A PART HEREOF COMPLETE LEGAL DESCRIPTION ON EXHIBIT Commonly Known As: 49170 Vista Ventura, La Quinta, CA 92253 Dated: September 4, 2012 ) STATE OF CALIFORNIA CS _} COUNTY OFA C 9 a L1�a before me, On �A 'e rrre v5 L notary public (insert name here) A personally appeared ,r who pro to me on the basis of satisfactory evidence to be the persooK whose name s are subscribed tot e within instrument and ac owledged to me tha he she/they executed the same i his er/t{ eier authorized thei strpumen(t the and that by Is/ erltheir slona (' person(.i' or the entity upon behalf of which the persor�{� acted, executed the instrument. s of I certify under PENALTY OF PERJURY under then as true the State of California that the foregoing paragraph a9 p Signe) in Counterpa Dollar Varden and correct. WITNESS my hand and official seal. (SEAL) Signature mail Tax Statements to: SAME AS ABOVE or Address Noted Below 11 & ERRIE ROSE Commission # 1902126 Notery Public -California v Z �;:=. LDS Angeles County My Conm. F.xpires Sep 26.20 and correct. WITNESS my hand and official seal. (SEAL) Signature mail Tax Statements to: SAME AS ABOVE or Address Noted Below 11 EXHIBIT "A" PARCEL1 LOT 34 OF TRACT NO. 25237, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE„ STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 228, PAGES 95 TO 99, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. RESERVING THEREFROM, FOR THE BENEFIT OF GRANTOR, ITS SUCCESSORS IN INTEREST AND OTHERS, NONEXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, MAINTENANCE, REPAIR, DRAINAGE, AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATDN REFERRED TO BELOW. FURTHER RESERVING UNTO GRANTOR, ITS SUCCESSORS AND ASSIGNS, TOGETHER WITH THE RIGHT TO GRANT AND TRANSFER ALL OR A PORTION OF THE SAME: A.ALL PREVIOUSLY UNRESERVED OIL RIGHTS, MINERAL RIGHTS, NATURAL GAS RIGHTS AND RIGHTS TO ALL OTHER HYDROCARBONS BY WHATEVER NAME KNOWN, TO ALL 3EOTHERMAL HEAT AND TO ALL PRODUCTS DERIVED FROM ANY OF THE FOREGOING (COLLECTIVELY, "SUBSURFACE RESOURCES"); AND B.THE PERPETUAL RIGHT TO DRILL, MINE, EXPLORE AND OPERATE FOR AND TC PRODUCE, STORE AND REMOVE ANY OF THE SUBSURFACE RESOURCES ON OR FROM SAIL- LOT, INCLUDING THE RIGHT TO WHIPSTOCK OR DIRECTIONALLY DRILL AND MINE FROM LANDS OTHER THAN SAID LOT, WELLS, TUNNELS AND SHAFTS INTO, THROUGH OR ACROSS THE SUBSURFACE OF SAID LOT, AND TO BOTTOM SUCH WHIPSTOCKED OR DIRECTIONALLY DRILLED WELLS, TUNNELS AND SHAFTS WITHIN OR BEYOND THE EXTERIOR LIMITS OF SAID LOT, AND TO REDRI_L, RETUNNEL, EQUIP, MAINTAIN, REPAIR, DEEPEN AND OPERATE ANY SUCH WELLS OR MINES, BUT WITHOUT THE RIGHT TO DRILL, MINE, EXPLORE, OPERATE, PRODUCE, STORE OR REMOVE ANY OF THE SUBSURFACE RESOURCES THROUGH OR IN THE SURFACE OR THE UPPER FIVE HUNDRED FEET (500') OF THE SUBSURFACE OF SAID LOT. PARCEL 2 A NONEXCLUSIVE EASEMENT FOR INGRESS, EGRESS, OVER THE COMMON AREA, AS DESCRIBED IN THE DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS, AND RESERVATION OF EASEMENTS RECORDED MARCH 12, 1991 AS INSTRUMENT NO. 82168. PARCEL 3 A NONEXCLUSIVE EASEMENT FOR ACCESS, INGRESS AND EGRESS FOR PEDES-RIAN AND VEHICULAR PURPOSES OVER THOSE PRIVATE STREETS DESCRIBED AS THE "PUD ROADS" AND "VENTURE PROPERTY ROADS," AS DESCRIBED IN THAT CERTAIN USE AGREEMENT AND GRANT OF NON-EXCLUSIVE EASEMENTS RECORDED ON FEBRUARY 25, 1987 AS INSTRUMENT NO. 52339, IN OFFICIAL RECORDS OF RIVERSIDE COUNTY, CALIFORNIA ("USE AGREEMENT"). RECORDING REQUESTED BY: EQUITY TITLE COMPANY WHEN RECORDED, MAIL TO: Bradley Thomas Cotten, Trustee C/O Western Reliance Funding 24422 Avenida De la Carlota Ste 180 Laguna Hills, CA 92653 APN: 658-220-014-0 TITLE ORDER NO.: OR1255903 r=erRnvv wn • 27417-004 THIS SPACE FOR REGORUER'S U6t UNLY GRANT DEED The undersigned Grantor(s) declare that the DOCUMENTARY TRANSFER TAX IS: $ 330.00 County XX computed on the full value of the interest of property conveyed, or _computed on the full value less the value of liens or encumbrances remaining thereon at the time of sale. OR transfer is EXEMPT from tax for the following reason FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Dollar Varde® and Debra Sue Varden HEREBY GRANT(S) to Bradley Thomas Cotten and Julie Anne Cotten, Trustees of The Cotter Family Trust u/d/t dated February 27, 2002 All that real property situated in the City of La Quinta, County of Riverside, State of California, described as: COMPLETE LEGAL DESCRIPTION ON EXHIBIT "A" ATTACHED HERETO & MADE A PART HEREOF Commonly Known As: 49170 Vista Ventura, La Quinta, CA 92253 Dated: September 4, 2012 STATE OF TEXAS COUNTY OF COLLIN On September 11 2012 , before me, Zack Thomas Logsdon notary public (insert name here) personally appeared Debra Sue Varden who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. Signed in Counterpart Debra Sue Varden r ZACK :TH JMIAS LOGSDON • My CorrmWion ExpWes Of ' API 04, 2016 WITNESS my hand and official seal. Signature .17„►"'� (SEAL) Mail Tax Statements to: SAME AS ABOVE or Address Noted Below. EXHIBIT "A" PARCEL1 LOT 34 OF TRACT NO. 25237, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 228, PAGES 95 TO 99, INCLUSIVE; OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. RESERVING THEREFROM, FOR THE BENEFIT OF GRANTOR, ITS SUCCESSORS IN INTEREST AND OTHERS, NONEXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, MAINTENANCE, REPAIR, DRAINAGE, AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION REFERRED TO BELOW. FURTHER RESERVING UNTO GRANTOR, ITS SUCCESSORS AND ASSIGNS, TOGETHER WITH THE RIGHT TO GRANT AND TRANSFER ALL OR A PORTION OF THE SAME: A.ALL PREVIOUSLY UNRESERVED OIL RIGHTS, MINERAL RIGHTS, NATURAL GAS RIGHTS AND RIGHTS TO ALL OTHER HYDROCARBONS BY WHATEVER NAME KNOWN, TO ALL GEOTHERMAL HEAT AND TO ALL PRODUCTS DERIVED FROM ANY OF THE FOREGOING (COLLECTIVELY, "SUBSURFACE RESOURCES"); AND B.THE PERPETUAL RIGHT TO DRILL, MINE, EXPLORE AND OPERATE FOR AND TO PRODUCE, STORE AND REMOVE ANY OF THE SUBSURFACE RESOURCES ON OR FROM SAID LOT, INCLUDING THE RIGHT TO WHIPSTOCK OR DIRECTIONALLY DRILL AND MINE FROM LANDS OTHER THAN SAID LOT, WELLS, TUNNELS AND SHAFTS INTO, THROUGH OR ACROSS THE SUBSURFACE OF SAID LOT, AND TO BOTTOM SUCH WHIPSTOCKED OR DIRECTIONALLY DRILLED WELLS, TUNNELS AND SHAFTS WITHIN OR BEYOND THE EXTERIOR LIMITS OF SAID LOT, AND TO REDRI_L, RETUNNEL, EQUIP, MAINTAIN, REPAIR, DEEPEN AND OPERATE ANY SUCH WELLS OR MINES, BUT WITHOUT THE RIGHT TO DRILL., MINE, EXPLORE, OPERATE, PRODUCE, STORE OR REMOVE ANY OF THE SUBSURFACE RESOURCES THROUGH OR IN THE SURFACE OR THE UPPER FIVE HUNDRED FEET (500') OF THE SUBSURFACE OF SAID LOT. PARCEL 2 A NONEXCLUSIVE EASEMENT FOR INGRESS, EGRESS, OVER THE COMMON AREA, AS DESCRIBED IN THE DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS, AND RESERVATION OF EASEMENTS RECORDED MARCH 12, 1991 AS INSTRUMENT NO. 82168. PARCEL 3 A NONEXCLUSIVE EASEMENT FOR ACCESS, INGRESS AND EGRESS FOR PEDESTRIAN AND VEHICULAR PURPOSES OVER THOSE PRIVATE STREETS DESCRIBED AS THE "PUD ROADS" AND "VENTURE PROPERTY ROADS," AS DESCRIBED IN THAT CERTAIN USE AGREEMENT AND GRANT OF NON-EXCLUSIVE EASEMENTS RECORDED ON FEBRUARY 25, 1987 AS INSTRUMENT NO. 52339, IN OFFICIAL RECORDS OF RIVERSIDE COUNTY, CALIFORNIA ("USE AGREEMENT'=). POST IN A CONSPICUOUS PLACE Certificate of Occupancy Community Development Department This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the California Residential Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 49-170 VISTA VENTURA Use classification: SINGLE FAMILY DWELLING Building Permit No.: 12-1471 Occupancy Group: R3 Type of Construction: VB Land Use Zone: RL Code Edition: 2010 Sprinkler Installed: YES Sprinkler Required: YES Owner of Building: COTTEN, BRADLEY THOMAS Address: 17 CALLE ANGELITOS City, ST, ZIP: SAN CLEMENTE, CA 92673 _________TOM HARTUNG (INTERIM)________________ By: KIRK KIRKLAND Building Official Date: SEPTEMBER 19, 2014 PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FI RE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert; CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 vrww.rvcfire.org April 8, 2013 Western States Fire Protection 1589 W. 9`h Street Upland, CA Re: Residential Fire Sprinkler Plan Review LAQ-1 3 -RS -01 8 49-170 Vista Ventura La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum '/ inch letters, shall be affixed adjacer-t to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require cedain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off tF.e water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shell not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Rre Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Underground Rough and Hydro static test: All underground piping shall be visible and pumped at normal operating pressure. (c) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be rEferred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to scheo ule irl.spection. Sincerely, \ �al Ja:. Stubble Fire Safety Specialist Building Permit Number: Project Description: SFR Exempt: Q (Materials may contain hazareous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submitted Datel 2/1/2013 Job Site Address 49-170 Vista Ventura Owners Name Brad & Jolie Cotton Number, Street, or PO Bout City, State, Postal Code Owner's Phone Number Owner's E -Mall Address k. _---.���Me`magersName'�Rowfant]�ome - ---- - -- _. _ --- w. _ _.v---�-,-•—_— ---, Project Manager's Phone Number 760-574-9048 Project Manager's E-mail Address I hollygLe4Ls@Dve.com Builder /Contractor I ACM Number, street or Po BoxI 20250 SW Acacia, #130 City, State, Postal Codel Newport Beach, Ca 92660 Project Square Footage 5,095 City Approval By Date of City Approval Materials To Be Discarded: Product Trash Asphalt Bdck/Block Cardboard Commingled Concrete Drywall Donated / Reuse* 'Describe Items Tons 9.68 Not recyclable 0.00 Recyclable 0.00 Recyclable 1.68 Recyclable 0.00 Recyclable 0.41 Recyclable IS Totals: Recycle Trash 10.'21 9.7 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons Projected Diversion: a1.2% Recyclable Recyclable Recyclable Recyclable 1 understand It Is the property owner's responsibility to submit copies of weight tickets or recelplis to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the Jobste waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or reuse, remeining materials generated from the first day of the project through the completion of the project In accordance with this plan. This DMP is Issued In the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still Issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of he DMP are adhered to. The property owner(s) and general contractor shall be kept Informed of the diversion progress through 61 -monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer station. Owner / Developer / Project Manager / Superintendent Date CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING P=RMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date:/S2DLSDeveloper: Agi:H1TFzTifaAt- ca -is rrao c -n ew A4AvuP4t5MiEif fAJC THE ewc LAVE 3 Tract No.:AZ37 Tract Name: mamnsmi ESrPyr r -f Lot No.(s): / Address(s): q9-470 Ula _ENTD04, I.P Qyinl rp► Phone Number: (t?tJ9 �' T— The The following are the requirements for Public Works Clearance to authorize issuanceRF ildin `SdE�rr ro e Building & Safety Department: / `�— CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW APR 16 2013 •3 TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW_ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW :)F LA QUINTA ❖ WALLS SIGNS, OTHER: PROVIDE ITEM #6 BELOW CITY COM114UN, I'! DEVELOPMENT 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date . If a precise grading plan creates the pad for approval, please withhold green sheJM-rJM AMOM �Certificate can be provided. d1NUla vi ► A' 'D 1 2. ," ttach geotechnical certification of grading plan compliance including compaction repots from a licensed Soils �/ Engineer. Recently rough graded residential developments which have a previousl7 aff0$ep p9technical certification are exempt from this requirement. t Attach recorded final map or title information/grant deed showing proposed building locatons are legal lots. Complete the attached <1 acre per lot or infill project Fugitive Dust Control projectMelm agreement or provide alternative & valid City approved PM10 plan set referenPM10 plans for commercial & residential developments (beyond 1 lot) are submitte �are subject to additional requirements. A current PM10 certification number is required (5/Attach a copy of the rough or precise SLading plan to the Public Works Department showing building location(s) for pad elevation verification. ` flood zone developments will require an approved flood plain development plan. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-cluinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: Date: / 2� Public Works Distribution: (--Z) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: T:1Checkksts - Forms & ApplicationsTorrns & ApplicationslGREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement (<1 acre/lot or Infill Project) Project Information Project Contractor: Project Phase ,(check one) ,��J( Construction [:1 Demolition Project Name: C.07TGY%1 2t.S! l76IJ Project Tract/Lot Numbers: Project Street Address: �% i3 237 � Lor 3 -170 V(0-0- V&J1v AA, 1 ,`- Total Acres in Active Construction (<1 acre per/ Lot): Anticipated Start Date: ,� / % / % 3 Anticipated Completion Date: 5 / //V PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control ring bus' ess a non -business hours. Name: C-4 Lkao CQ JC - Title: awL-CT Sc.3PC-AIL-1 n�nna Company Name: U STV_U cr1 dr.1 41ArJ"ErN Hv'r T;vc- Mailin Address: 2.0250 s. t+ U City, State, ZIP Code: �J cAt 4 y`LbbO Primary Phone #: L% qq - to I SO 10`3 7 (6 lz�- -- — y` Fax M - 11 S -2S Z13 24 Hour Emergency Phone#: 949- (c - $sZO Mid �c (op0 Cell Phone M 3 - % Y ib $ Email Address: 4e CLC W% CO • C urn K__PM10 Certificate M The above stated property owner (or authorized representative): Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; .• Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan- Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary-, Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; Shall hold harmless the City/County and its representatives from liability for an7acti s related to this dust control plan or any City/County initiated abatement activities. Signat a of rope y Owner or Authorized Representative Ddtd T"1Checklists - Forms d Applications\Forms d A.pplicationslGREEN SHEET cover & P1.410 less than 1 Acre Revised 9.25.09.doc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER ------------------------------------------------------------------------------- METHOD CF -1R Page 1 ------------------------------------------------------------------------------- Project Title.......... COTTEN MAIN RESIDENCE Proposed Date..02/28/13 13:17:46 Project Address........ 49-170 VISTA VENTURA ****** --------------------- Margin ---------- LA QUINTA, CA. *v8.1* 1 I Documentation Author... PAUL KANDARIAN ****** 1 Building Permit # I 73.58 Southland Energy Consultants I I -4.0% 1491 Glenneyre Street 0.55 1 Plan Check / Date 1 0.00 Laguna Beach, CA 92651 = Water Heating.......... _ 1 1 6.74 949-497-3591 32.3% 1 Field Check/ Date 1 Climate Zone........... 15 -------- 0.55 --------------------- Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE --------------------------------------------------------------- --------------------------------------------------------------------------- --------------------------------------------------------------------------- = _ MICROPAS8 ENERGY USE SUMMARY ---------------------------- On Grade = Energy Use Standard Proposed Compliance Percent _ (kTDV/sf-yr) ------------------------ Design ---------- Design ---------- Margin ---------- Improvement ----------- = Space Heating.......... 2.84 2.56 0.28 9.90 = Space Cooling.......... 73.58 76.52 -2.94 -4.0% = Ventilation Fans....... 0.55 0.55 0.00 0.0% = Water Heating.......... _ 9.95 6.74 3.21 32.3% Total -------- 86.92 -------- 86.37 -------- 0.55 -------- 0.6% *** Building complies with Computer Performance *** HERS Verification Required for Compliance ------------------------------------------------------------------------------- GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 3665 sf Building Type .............. Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Front Facing 30 deg (NE) Number of Dwelling Units_ 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 36650 cf Slab -On -Grade Area......... 3665 sf Glazing Percentage......... 26.% of floor area Average Glazing U -factor... 0.23 Btu/hr-sf-F Average Glazing SHGC....... 0.2 Average Ceiling Height..... 10 ft CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FORONSTRUC ON DA V ?! BY RECEIVED APR 162013 COMM �� D Ql1INTq EVELOPMENT J CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 ------------------------------------------------------------------------------- Project Title.......... COTTEN MAIN RESIDENCE Date..02/28/13 13:17:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type -------------- (sf) ----- (cf) Units ------ ----- le ----- ioned Type ------------- (ft) (sf) Housewrap ----- ------ ---------- Residence 3665 36650 1.00 4.0 Yes Setback 2.0 Standard Housewrap ATTIC ---------------------- AND ROOF DETAILS Frame R- R - Roof Roof Re- Emiss- Frame Spac- Value Value Vent Mass Rise fleet- ivity Depth ing Above Below Area Vent Roof Type (lb/sqft) ance (in.) (in.) Deck Deck Ratio High ----------- Tile --------- Heavy ---- ------ 4:12 0.20 ------ 0.90 ----- ----- ------ 3.5 24 oc ------ ------ ---- 0.00 0.00 1/300 0.00 OPAQUE SURFACES --------------- U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Metal ---- ----- ----- 626 0.084` 19 ----- 5 --- ---- --- 30 90 Yes --------- -------------- Non -Std 2 Wall Metal 535 0.084 19 5 120 90 Yes Non -Std 3 Wall Metal 375 0.084 19 5 210 90 Yes Non -Std 4 Wall Metal 540 0.084 19 5 300 90 Yes Non -Std 5 AtticRad Metal 3665 0.041 30 0 n/a 0 Yes Non -Std 6 Door Wood 52 0.500 0 0 30 90 Yes 4.5.1 A,; Entry Door PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar JA4 Location/ Surface ------------ (ft) ------ Factor R-val Gains Reference Comnents 7 SlabEdge 110 -------------------- 0.730 R-0/Oin -------------- No 4.4.7 --------------------- Al 8 SlabEdge 196 0.730 R-0/Oin No 4.4.7 Al CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 Project Title.......... COTTEN MAIN RESIDENCE Date..02/28/13 13:17:46 I MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Front (NE) 10.0 0.230 0.200 30 90 Standard F1/Wd/Vin Op. Dual 2 Door Front (NE) 152.0 0.230 0.200 30 90 Standard F2/Wd/Vin Hin. Dual 3 Wind Left (SE) 30.0 0.230 0.200 120 90 Standard L1/Wd/Vin Op. Dual 4 Wind Left (SE) 125.4 0.230 0.200 120 90 Standard L2/Wd/Vin Op. Dual 5 Wind Back (SW) 36.0 0.230 0.200 210 90 Standard B1/Wd/Vin Op. Dual 6 Wind Back (SW) 90.9 0.230 0.200 210 90 Standard B2/Wd/Vin Op. Dual 7 Door Back (SW) 338.4 0.230 0.200 210 90 Standard B3/Wd/Vin Hin. Dual 8 Wind Right (NW) 49.0 0.230 0.200 300 90 Standard R1/Wd/Vin Op. Dual 9 Door Right (NW) 100.8 0.230 0.200 300 90 Standard R2/Wd/Vin Hin. Dual 10 Skyl Horz 18.8 0.230 0.200 30 0 None SKYLIGHT/Met/Fixed OVERHANGS ---Window--- ------------Overhang------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- 1 Window 10.0 n/a 4.5 2.0 0.0 n/a n/a 2 Door 152.0 n/a 8.0 2.0 0.0 n/a n/a 3 Window 30.0 n/a 4.5 2.0 0.0 n/a n/a 4 Window 125.4 n/a 4.5 2.0 0.0 n/a n/a 5 Window 36.0 n/a 4.5 2.0 0.0 n/a n/a 6 Window 90.9 n/a 4.5 2.0 0.0 n/a n/a 7 Door 338.4 n/a 8.0 2.0 0.0 n/a n/a 8 Window 49.0 n/a 4.5 2.0 0.0 n/a n/a 9 Door 100.8 n/a 8.0 2.0 0.0 n/a n/a THERMAL MASS ------------ Area Thick Hea= Conduct- Surface Mass Type (sf) (in) Cap ivity UIMC R -value Location/Comments --------------- ------ ----- ------------- ----------- ---------------------- 1 SlabOnGrade 3252 3.5 28.0 0.98 4.60 R-0.0 TYPICAL 2 S1abOnGrade 413 3.5 28.0 0.98 1.80 R-2.0 WALLS/CABS 3 InteriorVert 391 1.0 24.0 0.67 1.70 R-0.0 CNTR/SHWR/TUB CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN MAIN RESIDENCE Date..02/28/13 13:17:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- HVAC SYSTEMS ------------ Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity ---------------- ----------- ----- ------------- -------- -------- -------- Furnace 0.800 AFUE n/a n/a n/a n/a n/a ACSplit 13.00 SEER No No No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) ----------------------------------------------------- Furnace 53988 n/a n/a n/a ACSplit n/a 44766 55554 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R -value Leakage Area Ducts ----------------------------------------------------------- Furnace Attic R-8 Yes No No ACSplit Attic R-8 Yes No No FAN SYSTEMS Flow Power System Type (cfm) (W/cfm) -------------------------------- Standard 66.65 .25 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN MAIN RESIDENCE Date..02/28/13 13:17:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R -value ---------------- -------- ------------------- -------------- ------ ---------- 1 Instantaneous Gas Standard 2 0.81 n/a R-n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard user entered U-Factor(s) or F-Factor(s) This building incorporates a Housewrap/Air Infiltration Retarder. This building incorporates a Radiant Barrier. This building incorporates a Cool Roof. This building incorporates a High Mass Design. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate. *** This building incorporates HERS verified High Quality Insulation Installation. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. i CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 Project Title.......... COTTEN MAIN RESIDENCE Date..02/28/13 13:17:46 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- REMARKS Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temps., coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. FRONT: STREET FACADE NOTE: GOVERNING AGENCY MAY REQUIRE RIGID DUCT CONNECTION FROM RETURN AIR GRILL TO FURNACE. FAU: SEE MECH. PLANS .80 AFUE A/C: SEE MECH. PLANS 13.0 SEER WH:(2) TANKLESS NORITZ N -069M OR APPROVED EQUAL CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 7 Project Title.......... COTTEN MAIN RESIDENCE Date..02/28/13 13:17:46 I MICROPAS8 v8.1 File-COTTEN_MAIN Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... HOLLY GRAVES Name.... PAUL KANDARIAN Company. LOHRBACH STUDIO Company. Southland Energy Consultants Address. 31742 S. COAST HWY. Address. 1491 Glenneyre Street LAGUNA BEACH, CA 92651 Laguna Beach, CA 92651 Phone... 949-661-5068 Phone... 949-497-3591 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) Signed.. (date) CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER ------------------------------------------------------------------------------- METHOD CF -1R Page 1 ------------------------------------------------------------------------------- Project Title.......... COTTEN CASITA _ (kTDV/sf-yr) _----------------------- Date..02/25/13 15:28:39 Project Address........ 49-170 VISTA VENTURA ****** --------------------- 5.30 LA QUINTA, CA. *v8.1* I I Documentation Author... PAUL KANDARIAN ****** I Building Permit # I -13.9% _ Southland Energy Consultants I I' 1.74 1491 Glenneyre Street 0.0% _ I Plan Check / Date.1 36.35 Laguna Beach, CA 92651 16.40 1 1 = Total 949-497-3591 -------- 151.14 1 Field Check/ Date I Climate Zone........... 15 complies with --------------------- Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-COTTEN_CASITA Wth-CTZ15S08 User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE --------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS8 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance Percent = _ (kTDV/sf-yr) _----------------------- Design -------------------- Design Margin ---------- Improvement = ----------- - = Space Heating.......... 5.30 5.00 0.30 5.7% _ = Space Cooling.......... 109.22 124.45 -15.23 -13.9% _ = Ventilation Fans....... 1.74 1.74 0.00 0.0% _ = Water Heating.......... _ 36.35 19.95 16.40 45.1% _ - = Total -------- 152.61 -------- 151.14 -------- 1.47 -------- 1.0% _ _ *** Building complies with Computer Performance _ *** HERS Verification Required for ----------------------------------=-------------------------------------------- ------------------------------------------------------------------------------- Compliance GENERAL INFORMATION HERS Verification.......... Required Conditioned Floor Area..... 638 sf Building Type.......,....... Single Family Detached Construction Type ......... New Natural Gas at Site ....... Yes Building Front Orientation. Front Facing 30 deg (NE) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 6380 cf 638 sf 22.6 % of floor area 0.25 Btu/hr-sf-F 0:2 10 ft CITY OF LAQUINTA BUILDING & SAFETY DEPT. APPROVED FO��R��CONSTRUC ON ,off l_L`t l 1'� 8Y vz letlI CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN CASITA Date..0+2/25/13 15:28:39 ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ I MICROPAS8 v8.1 File-COTTEN_CASITA Wth-CTZ15S0`8 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage.or Zone Type -------------- (sf) ----- (cf) Units le ------ ----- ----- ioned Type (ft) (sf) Housewrap ------------- ----- ------- ---------- Residence 638 6380 1.00 4.0 Yes Setback 2.0 Standard No ATTIC AND ROOF DETAILS ---------------------- Frame R- R - Roof Roof Re- Emiss- Frame Spac- Value Value Vent Mass Rise flect- ivity Depth ing Above BElow Area Vent Roof Type (lb/sqft) ance (in.) (in.) Deck DE:ck Ratio High ----------- Tile --------- Heavy ---- ------ ------ 4:12 0.20 0.90 ----- ----- ------ ------ ------ ---- 3.5 24 oc 0.00 0.00 1/300 0.00 OPAQUE SURFACES --------------- U- Sheath- Solar Append -x Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ 1 Wall ----- Metal ---- ----- ----- ----- 290 0.084 19 6 --- ---- --- --------- -------------- 30 90 Yes Non -Std 2 Wall Metal 250 0.084 19 6 120 90 Yes Non -Std 3 Wall Metal 226 0.084 19 6 210 90 Yes Non -Std 4 Wall Metal 250 0.084 19 6 300 90 Yes Non -Std 5 AtticRad Metal 638 0.041 30 0 n/a 0 Yes Non -Std PERIMETER LOSSES ---------------- Appendix Length F2 Insul Solar JA4 Loca-ion/ Surface (ft) Factor R-val Gains Reference Comments -------=---- 6 S1abEdge ------ 43 -------------------- 0.730 R-0/Oin -------------- ---------------------- No 4.4.7 Al 7 S1abEdge 73 0.730 R-0/Oin No 4.4.7 Al I CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN CASITA Date..02/25/13 15:28:39 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS8 v8.1 File-COTTEN_CASITA Wth-CTZ15S08 User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ---------------- -------- 1 Wind Front (NE) 40.5 0.250 0.200 30 90 Standard F1/Wd/Vin Op. Dual 2 Door Back (SW) 104.0 0.250 0.200 210 90 Standard B3/Wd/Vin Hin. Dual OVERHANGS ---Window--- ------------Overhang------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- 1 Window 40.5 n/a 4.5 2.0 0.0 n/a n/a 2 Door 104.0 n/a 8.0 2.0 0.0 n/a n/a THERMAL MASS ------------ Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity UIMC R -value Location/Comments --------------- ------ ----- ------------- ----------- ---------------------- 1 SlabOnGrade 567 3.5 28.0 0.98 4.60 R-0.0 TYPICAL 2 S1abOnGrade 71 3.5 28.0 0.98 1.80 R-2.0 WALLS/CABS 3 InteriorVert 125 1.0 24.0 0.67 1.70 R-0.0 CNTR/SHWR/TUB HVAC SYSTEMS ------------ Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or CID Airflow Draw Capacity ----------------- Furnace ----------- ----- ------------- 0.800 AFUE n/a n/a -------- n/a -------- n/a -------- n/a ACSplit 13.00 SEER No No No No No C CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN CASITA Date..02/25/13 15:28:39 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS8 v8.1 File-COTTEN_CASITA Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- HVAC SIZING DUCT SYSTEMS Verified Verified Verified System Total Sensible Design Maximum Type ------------- Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) (Btu/hr) -------------------- (Btu/hr) ---------- (Btu/hr) Furnace 16074 n/a n/a ---------- n/a ACSplit n/a 12880 15984 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R -value ---------------- -------- ------------------- -------------- ------ ---------- 1 Instantaneous Gas Standard 1 0.81 n/a R-n/a Verified Verified Verified System Duct Duct Duct Surface Buried Type ------------- Location ----------- R -value Leakage Area Ducts Furnace Attic -------------------------- R-4.2 Yes No --------- No ACSplit Attic R-4.2 Yes No No FAN SYSTEMS Flow Power System Type ---------------- (cfm) (W/cfm) --------- Standard ------- 36.38 .25 WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R -value ---------------- -------- ------------------- -------------- ------ ---------- 1 Instantaneous Gas Standard 1 0.81 n/a R-n/a f CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN CASITA Date..02/25/13 15:28:39 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I MICROPAS8 v8.1 File-COTTEN_CASITA Wth-CTZ15S08 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard user entered U-Factor(s) or F-Factor(s) This building incorporates a Radiant Barrier. This building incorporates a Cool Roof. This building incorporates a High Mass Design. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate. *** This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS Note: The loads shown are only one of the criteria affecting the - selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temps., coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. FRONT: STREET FACADE NOTE: GOVERNING AGENCY MAY REQUIRE RIGID. DUCT CONNECTION FROM RETURN AIR GRILL TO FURNACE. FAU: SEE.MECH. PLANS .80 AFUE A/C: SEE MECH. PLANS 13.0 SEER WH:(1) TANKLESS NORITZ N -069M OR APPROVED EQUAL CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... COTTEN CASITA Date..02/25/13 15:28:39 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS8 v8.1 File-COTTEN_CASITA Wth-CTZ15S03 I User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features specifications needed to comply with Title -24, Parts 1 California Code of Regulations, and the administrative implement them. This certificate has been signed by the overall design responsibility. DESIGNER or OWNER and performance and 6 of the regulations to inc.ividual with DOCUMENTATION AUTHOR Name.... HOLLY GRAVES Name.... PAUL KANDARIAN Company. LOHRBACH STUDIO Company. Southland Energy- Consultants Address. 31742 S. COAST HWY. Address. 1491 Glenneyre Street LAGUNA BEACH, CA 92651 Laguna Beach, CF. 92651 Phone... 949-661-5068 Phone... 949-497-3591 License. Signed.. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) (date)