BRES2015-031378-495 CALLE TAMPICO }
LA QUINTA, CALIFORNIA 92253
4
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BRES2015-0313
Property Address: 77330 VISTA ROSA
APN: 658220029
Application Description: SATHER GLEN & ANN CLOSET ADDITION
Property Zoning:
Application Valuation: $8,888.00
Applicant:
JMA ARCHITECTURE, INC.
P.O. BOX 778
PALM DESERT, CA 92261
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: ��B License No.: 541336
Date:, 1 r�-1' Contractor:
OWNER -BUILDER DECLARATI N
I hereby affirm under penalty of perjury that I am exempt rom the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a -
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
f
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/21/2015
Owner:
GLENN & ANN SATHER
77330 VISTA ROSA
LA QUINTA, CA 92253
Contractor:
RON SAWYER CONSTRUCTION INC
78525 AVENUE 41
BERMUDA DUNES, CA 92203
(760)200-0893
Llc. No.: 541336
WORKER'S COMPENSATION DECLARATION -
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the wor r which this permit is issued.
I have and will maintain workers%compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued! My workers' compensation insurance carrier and policy number are:
Carrier: _ • Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if houId become subject to the
workers' compensation provisions of Section o he Labor Code, I shall forthwith
comply with those provisions.
Dater �- (� Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSA N COV RAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIE CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application. -
1..Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as'a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city r upon the
above-mentioned property for inspection purposes.
( C�
Date: " �1' (J Signature (Applicant or Agent):
i
xF: DESCRIPTION r
ACCOUNT f {CITY. c ANiOUNTy c%�.¢ PAID
sk
c:
1PAIDDATEh:
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400 =
0 $62.36
$62.36
9/21/15
E� -fi.a �' t o 4 Y j5 k..64
PAID:BY
Y: �4 Y{Eto
METHOD
c+ RECEIPT #4 CHECK # a
V
3 'CLTD BY
E
RON SAWYER CONSTRUCTION INC
CHECK
MR226 27320
MFA
p § § L 9 -tE1 .Q.q .' £'
DESCRIPTIONriv �cA000UNT�1
d i E.R` iE-X 'Ys`
QTY
'f t^h.
AMOUNTF PAIp {
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.40 $17.40
9/21/15
PAID BY y
s MEO
T
„ -RECEIPT#''� CHECK#
CLTD BY
x
RON SAWYER CONSTRUCTION INC
CHECK
MR226 27320
MFA
`DESCRIP..TION?
ACC0.l1NTs'QTY.fj
AMOUNT x� PAIDffi
PAID DATE+
P
r4 h
6
r .
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83 $120.83
9/21/15
PAIDBYxNNAP._x�
METHODsK��
RECEIPT#z ` �%<d'CHECK#ECLTUBYx.
r c�..,a4
1 >
v<r#.
y
RON SAWYER CONSTRUCTION INC
CHECK
MR226 27320
MFA
:DESCRIP,TION
wACCOUNT
F
AMOUNT s PAID
5 .
PAID DATE?.
_kgTY�s
ADDITION, FIRST 100 SF PC .
101-0000-42600
0
$171.14 $171.14
9/21/15
"..r PAID_BY c
RECEIPT #� X4s CHECK # V;
CLTD BY�'.
s r"='�aµMETHOD
. ? cis
;+ §
RON SAWYER CONSTRUCTION INC
CHECK
MR226 27320
MFA
Total Paid for ADDITION: $371.73 $371.73
SCRIPTI
"--ACOUNT fir
"AMOUNTi
0462;x`..
PAID;DATEDE
.. _
?,�
HOURLY PLAN CHECK -YES
101-0600-42600
2
$140.00
$140.00
9/21/15
s *
BY4
METHOD
RECEIPT ;#
' CHECK #
CLTD BY
n .,PAID y.c
$,.,�.. t
o g�
RON SAWYER CONSTRUCTION INC
CHECK
MR226
27320
MFA
DESCRIPTIONtbz <q„; Y
s ACCOUNTy
QTY
AMOUNT
AID
PAID DATE;
§ +
8.
*Ppl
, ,
HOURLY PLAN CHECK - YES
101-0000-42600
1
$70.00
$70.00
9/21/15
,�-a,y
} s
PAIDtiBY
M ETHOD
n
# �, =x
b..a .:.
CHECK #.:
.:
” CLTD BY
h {
z r.
<RECEIPT
z
c
RON SAWYER CONSTRUCTION INC
CHECK
MR226
27320
MFA
Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $210.00
" " DESCRIPTION' b
a ` ">>
:QTY}
'. E." AMOUNTc ` �
s T �4PAID z Y
DATE`
,i
,ACCOUNT&
, ,.
,PAID
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
9/21/15
t ':" e •S :+'� s� a
PAID BY
'ice 1 ai ?
METHOD
F q
RECEIPT M
EA 'Y' ,. Q 'Y
r, CHECK #
J
CLTD BY
_x
3 Cf q. i.�:-r s .z ...,,.: � ?o� `LY' .i4=� a.3.h,
e r
�..
ss
�'
RON SAWYER CONSTRUCTION INC
CHECK
MR226
27320
MFA
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
'�
ACCOU
Ts<x,
fy
UN
PA(D
PAIDD.DATEcDESCRIPTION
�
,
rwE •'r .. R
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$145.03
9/21/15
„iqt
$ PAID'BYr Ew
�
METHOD'° u
RECEIPT ##
< CHECK # ;
'CLTD BY
. ,
,£ r Y
,
RON SAWYER CONSTRUCTION INC
CHECK
'.M11226
27320
MFA
bESCRIP,TION
:
;'4 :ACCOUNT b;
=QTY
+ AMOUNT k $
c PAID
PAID DATE:
,.
���
s .:I
RESIDENTIAL, FIRST 1,000SF, PC-
101-0000-42600
0
$47.86
$47.86
9/21/15
„c c PAID BY ;f
71
METHOD
Cd
RECEIPT
i
CHEGK # e "
CLTQ BY#
Y #
RON SAWYER CONSTRUCTION INC
CHECK
MR226
27320
MFA
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
�.DESCRIPTIUNttrX�e,�
` Xp=ACCOUNTk
'Q
='z�AMOUNT y,
"FU
PAID
PAID;DA E
-ri. �: ;- x'�'; F.
,"'
x}'* ,� x ...ros its
#.,
$.y',{+d,m cer 2+n 'CEi
x"
Y',i b, x lw.v'
i pj e/ci
APPLIANCE REPAIR/ALTERATION
101-0000-42402
.0
$12.09
$12.09
9/21/15
PATO BYE
*z. -z• -y?; TL"' d ri.a
METHOD
,.,,+iMEi
- RECEIPT # x
CHECK # `,
CLTD BYE
ti §ivR�s fx -e -:.. n :s :%.
�. ma
x. -:-v: '. n .r
+.. a
- v - x•.. r.. n
rot +. •:+x rn'
Wt
RON SAWYER CONSTRUCTION INC
CHECK
MR226
27320
MFA
r �ta-x 7+ ,__ z-+ gs.
DESCRIPTION
-:+€^" ,�. ,:sr . i4rs. v .,,„ N.t�`
ACCOUNTAMOUNTO",
•4;
�-.:. »g.,, z - •.
..
DATE;
..
A-4,
a Y xPAlf) ,`';'PAID
APPLIANCE REPAIR/ALTERATION PC ,
101-0000-42600
0
$4.83
$4.83
9/21/15
'� PAID BY? 33
+s «� �
`
# 4a
¢� CHECK #
v.
BY'i
3w vtxMETHOD'
�n�ax;YRECEIPT
yCLTD
RON SAWYER CONSTRUCTION INC
CHECK
MR226
27320 r
MFA
Total Paid for MECHANICAL: $16.92 $16.92
DESCRIPTIONp`�k�ACCOUNTe*'QTY
`
;PAIDDATE
aAMOUNT;PAID�°
SMI - RESIDENTIAL
101-0000-20308
0
$1.16
$1.16
9/21/15
j. .rc ?,
+,,y #, -PAID`BY
i ` METHOD,y '$,sRECEIPT#$
's4
CLTD BYE,.
a��
zEs3CHECK# r=
RON SAWYER CONSTRUCTION INC
CHECK
-MR226
27320•
MFA
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.16 $1.16
TOTALS:
Description: SATHER GLEN & ANN CLOSET ADDITION
iCHRONOLOGY
Type: BUILDING, RESIDENTIAL
Subtype: ADDITION
Status: ISSUED
Applied: 8/19/2015 PJU
Approved: 9/18/2015110
Parcel No: 658220029 Site Address: 77330 VISTA ROSA LA QUINTA,CA 92253
Subdivision: TR 25237
- •Block:
Lot: 54
Issued: 9/21/2015 MFA
Lot Sq Ft: 0
Building Sq Ft: 0
Zoning:
Finaled: ,
Valuation: $8,888.00
- Occupancy Type:
P Construction Type:
Expired: 3/19/2016 MFA
No. Buildings: 0
No. Stories: -O ' I
No. Unites: 0
FROM CONSULTANT
Details: '110 SQ. FT. ADDITION TO CLOSET. PER 2013 CRC CODES
r
-
-8/28/2015
- .. - �, . � Approv�ed�to� ssued�•,�� •
R
iCHRONOLOGY
# 30," 3
'CHRONOLOGY TYPE
.y;,.
-ACTION DATE COMPLETION DATE.
NOTES
- .. - �, . � Approv�ed�to� ssued�•,�� •
R
Printed: Monday, September 21, 2015 12:38:11 PM
1of4
"`'
iCHRONOLOGY
'CHRONOLOGY TYPE
.y;,.
-ACTION DATE COMPLETION DATE.
NOTES
NOTE
JIM JOHNSON
,9/10/2015
9/18/2015
PENDING STRUC APPROVAL
-PLAN CHECK COMMENTS _
FROM CONSULTANT
MARY FASANO'
8/28/2015
-8/28/2015
RECEIVED.
PLAN CHECK PICKED UP
MARY FASANO
9/3/2015
9/3/2015
t
PLAN CHECK -SUBMITTAL
PLAN CK SUBMITTED BY ARCHITEC JMA / CONTACT RYAN
PHILIP JUAREZ
8/18/2015
8/18/2015 —
RECEIVED
-ARIAS 760346-6155
TELEPHONE CALL
JIM JOHNSON
9/2/2015
9/2/2015
CALLED RYAN TO INFORM HIM PLANS ARE READY FOR
CORRECTIONS
TELEPHONE CALL
JIM JOHNSON
9/18/2015
9/18/2015
CALLED RYYAN TO INFORM HIM PLANS ARE READY TO ISSUE.
NEED SCHOOL FEE LETTER.
Printed: Monday, September 21, 2015 12:38:11 PM
1of4
"`'
-CONDITION
,7
��"`,DATE�
A
-f9_`DATE4-
P�.;;` ATE43,�-� �7d
D
-.4" "VAN" hl,
PE
'STATUS
k
UIR
SATISFIEWi�
READY TO ISSUE
9/10/2015
PENDING
CHECKLIST
CONTACTS
STATE r q�'� FAX,. EMAIL
S PHONE-
-
APPLICANT JMA ARCHITECTURE, INC.
P.O. BOX 778
PALM DESERT
CA
92261 (760)200-0893
ARCHITECT JMA ARCHITECTURE, INC.
P.O. BOX 778
PALM DESERT
CA
92261 (760)200-0893
CONTRACTOR 'RON SAWYER CONSTRUCTION INC 78525 AVENUE 41
BERMUDA
CA
92203 (760)200-0893
DUNES
OWNER GLENN & ANN SATHER 77330 VISTA ROSA
LA QUINTA
CA
92253 (760)200-0893
..
FINANCIAL
. . .... ...
INFOWAfION'
;04%.........
. . . . . . . . . . . . . ...
DESCRIPTION,
PAID :PAID.
Yt.
-,1;3 5:ztt��
�Mv
7 BY
ADDITION, EA
.101-000.0-42400
0
$62.36
$62-36, 9/21/15
MR226
27320
CHECK-
RON SAWYER
MFA
,ADDITIONAL 500 SF
CONSTRUCTION INC
ADDITION, EA
RON SAWYER
101-0000-42660
0
$17.40
$17.40 9/21/15
MR226
CHECK
MFA
ADDITIONAL 500 SF PC
CONSTRUCTION INC
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83 9/21/15
MR226
27320
CHECK
RON SAWYER
MFA
CONSTRUCTION INC
ADDITION, FIRST 100 SF
RON SAWYER
101-0000-42600
0
'$171.14
$171.14 9/21/15
MR226
27320
MFA
PC. -
CONSTRUCTION INC
Total Paid for ADDITION:
$371.73
$371.73
HOURLY PLAN CHECK -
RON SAWYER
101-0000-42600
2
$146.00
$140.00
0/21/15
MR226
27320
CHECK.
MFA
YES
CONSTRUCTION INC
HOURLY PLAN CHECK -
RON SAWYER
101-0000-42660
1
$70.00
$70.00
9/21/15
MR226
27320
CHECK
MFA
YES
CONSTRUCTION INC
Total Paid for BLDG CITY STAFF - PER.HOUR:
$210.00
$210.00
Printed:. Monday, September 21, 2015 12:38:11 PM 2 of 4
CRSYSTEMS'
DESCRIPTION
ACCOUNT ..
771
Q TY
AMOUNT
PAID
PAID OATE.,
yRECEIPT ;#
CHECK #
METHOD ,
PAID BY
CLTD
13Y .
{`
'
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
9/21/15
MR226
27320
CHECK
RON SAWYER
MFA
CONSTRUCTION INC
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00
BSA:
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$145.03'
9/21/15
MR226
27320
CHECK
RON SAWYER
MFA
1,000SF
CONSTRUCTION INC
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
9/21/15
MR226
27320
CHECK
RON SAWYER
MFA
1,000SF, PC
CONSTRUCTION INC
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
APPLIANCE
101-0000-42402
0
$12.09
$12.09
9/21/15
MR226
27320
CHECK
RON SAWYER
MFA
REPAIR/ALTERATION
CONSTRUCTION INC
APPLIANCE
101-0000-42600
0
$4.83
$4.83
9/21/15
MR226
27320
CHECK
RON SAWYER
MFA
REPAIR/ALTERATION PC
CONSTRUCTION INC
Total Paid for MECHANICAL:. $16.92 $16.92
SMI - RESIDENTIAL
101-0000-20308
0
$1.16
$1.16
9/21/15
MR226
27320
CHECK
RON SAWYER.
MFA
CONSTRUCTION INC
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.16 $1.16
TOTALS:
,....- PARENT..PROIECTS: ,.,.,,.. ,.., ... ,,..,.., ..,,,.. ,..
Printed: Monday, September 21, 2015 12:38:11 PM. 3 of 4
' SYSTEMS
STRUCTURAL -,2 WK
YOUNG
8/18/2015
9/1/2015
8/27/2015
REVISIONS REQUIRED
DOC
9/2/2015
JIM JOHNSON
ENGINEERING
77-330 VISTA
0.
'
NON-STRUCTURAL -
JIM JOHNSON
8/19/2015
9/2/2015
9/2/2015
REVISIONS REQUIRED
SCHOOL FEES BRES2015-
2 WK
DOC
9/2/2015 =
-
'
2ND BLDG NS (1
.WK)
JIM JOHNSON
9/9/2015
9/16/2015
9/10/2015.
APPROVED
0313.pdf
-
IST REVIEW -
2ND BLDG STR (1
YOUNG
9/9/2015
9/16/2015 7;
9/17/2015
READY FOR APPROVAL
DOC
WK)
ENGINEERING
STRUCTURAL
-
0
-
BOND INFORMATION
:�•-sem. >:,.� ,.. .,� s:;,. �»*�-,��:•� . ,•,.�.�, ..,r� , ::A.:w� �• � a-.�, ..�,.�._. �..___..>: . t.,--,.•
Attachment:T a = CREATED g�> _ 'O.UVNER� ... :A°. DESCRIP:TION, •,4PATHNAME
,
SUBD'IR =ETRAKITENABLED
.. s,. N.. _
DOC
9/2/2015
JIM JOHNSON
77-330 VISTA
77-330 VISTA
0.
ROSA.docx
ROSA.docx
'
SCHOOL FEES BRES2015-
SCHOOL FEES BRES2015-
DOC
9/2/2015 =
JIM JOHNSON
'
0
0313.pdf
0313.pdf
-
IST REVIEW -
y
BRES 2015-0313 K5
DOC
8/27/2015
KATHRYN SAMUELS
STRUCTURAL
-
0
-
(ist).doc-
COMMENTS
_
1ST REVIEW -
NEW CITY
-
DOC
8/27/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
R 0
TRANSMITTAL
2015-0313 (lst)_l.pdf
-
2ND REVIEW -
NEW CITY
DOC
-9/17/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
0
TRANSMITTAL
2015-0313 (2nd).pdf
Printed: Monday, September 21, 2015 12:38:51 PM 4 of 4
CIRWYSTEMS
Bin #4 G
Permit # /� /�
City of La Q uin to
Building 8z Safety Division
W�► P.O. Box 1504 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking•Sheet
Project Address: 77
I
Owner's Name: '62 -n d- rl n (1n L i
A. P. Number: (o S" 22i7 .0 2
Address: % - 3 3 0
Legal Description:
City, ST; Zip: I-cA- QA
o
Contractr:INsh"
Te ec
0/7.
»>s>>
Address: -756526- ( I
Project Description: 1/0 } (f)0t l—......
City, ST, Zip:
ct-hd
Tele h ne•
o . - Lt�n �-CM,,2,
P 2.0-
State Lie. # : 654 31aj1P
City Lic. #;
Ar ., Engr., Designer:
Address: Zt7
City., ST, Zip: G �� �eSF'{^ l/► 9 ZZ 60
Tele h one: D
P 6 �5
3 S
y �
7 b 6
Con tructi T -3
s on e: Occupancy:
O
Y Y�
P P
State Lie. #�•Z 4 2 6
-Iter r Demo
type (circle one): �ARepairai
Name of Contact Person(i�
G� T
Sq. Ft.: Jl7
#Stories:
Units:
Telephone # of Contact Person: -7b0 3 6 6 /S5-
Estimated Value of Project- '7,5:'_/0(20
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
\
Item
Amount
Structural Cafes.
_
Reviewed, ready for corrections
Plan Check Deposit
Truss Cates.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
god Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
Ii.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
3' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
y�$
�a c�a�rado�
YOUNG
o o
ENGINEERINGW
a .
' r• . Letter
of Transmittal. -
To: City of La Quints f Today's Date: ' -
9-17-15
78-495 Calle Tampico : City Due
Date:
9-16-15
La Quinta, CA 92253 Project Address:..
77330 Vista Rose
Attn: Kay s ` Plan Check #:
BRES 2015-0313
Submittal:. ❑ "
15t El
4m ,
❑
3rd ❑'
"Other:
We are forwarding: ®.' "By Messenger
❑ ' , By Mail (Fed Ex or UPS) ❑ Your Pickup
•,#
Includes: # Of Descriptions: ,
Includes:
Of , Descriptions:
Copies: r 3
"Copies: ,
ElStructural Plans
®'
1 Revised Structural Plans
® 1 Structural Calculations
®
1 Revised Struct. Calcs
• Truss Calculations Floor.,
❑
❑
N
Revised Truss
and Roof
❑ Soils Report 411
❑
Revised Soils Report
Structural Comment List/,
❑
` r Approved Structural Plans
Responses -
,
' ® 1 Redlined Structural Plans
❑ -, , Approved Structural Calcs `
' ❑ Redlined Structural Calcs
❑ ...
Approved Truss Calcs
❑ Redlined Truss Calcs
_ ❑
- _ Approved Soils Report
❑ Redlined Soils Reports
❑
Other:
Comments: Structural'content is approvable.
If you have any questions,• please call.' J"
Time =1 HR
..,.,`
This Material Sent for:,e•,
❑ Your Files- {.
y
Per Your Request
❑ Your. Review
❑
"Approval
• ❑ Checking
❑
'At the request of:
Other: ❑
y'
BY: Kathryn Samuels.
Palm Desert Office :.Z .(760)'772-5107 "
Other . ❑ .
r
♦ 4.
i
F
�. BUILDING ENERGY ANALYSIS REPORT
RECEIVED
PROJECT: AUG. 1 8 2015
Sather Residence CITY OF LA QUINTA
. 77-330Vista Rosa
COMMUNITY DEVELOPMENT
`La Quinta, CA 92253
Project Designer:
JMA Architecture' and Engineering
73-995 EI Paseo Suite 203
W s Palm Desert, CA 92260
y (760) 346-6155,-��
CIS :f1T
EPBUILDIN!C L)i
Report Prepared by FOR U', -i"``TION
l
Jon Scott DATE q JS LS t�
Scott Design and Title 24, Inc, - —
`� 77-085 Michigan Drive
Palm Desert, CA 92211
,(760)`200-4780.
L RECEIVED
of
SEP 0 9 2015 t
Job Number: CITY OF €:,:A QUINTA
COMMUNITY DEVELOPMENT
Date:
8/7/2015•
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC —www.energysoft.com.
Ene Pro 6.7 ;y E - nergySoft User Number: 6712. ID:
.. I
l
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD
Project ame: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis
Input File Name: Sather-JMA-15.xml
C FIDRF-01'
Page 1 of 9
GENERAL INFORMATION
®®�
ENERGY USE SUMMARY
01
Project Name Sather Residence
04
00,
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 77-330 Vista Rosa
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 80
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 5490
1s A�
Number of Zones 2
16
Slab Area (ft) 5490
17�(�
Number of Stories 1
18
Addition Cond. Floor Area 110
^91
Natural Gas Available Yes
20
Addition Slab Area (ft2) 110
�t 1
Glazing Percentage (%) 22.6%
Amw
COMPLIANCE RESULTS
01 Building Complies with Computer Performance �W
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shoswn`tbelow
♦Ao
Registration Number: �4p® Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-07 09:42:40
®®�
ENERGY USE SUMMARY
04
00,
06
07
08
Energy Use (kTDV/ft2-yr)
Sta�nSarard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
Iv 11.90
11.24
0.66
5.5%
Space Cooling
247.30
243.63
3.67
1.5%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water HeatingA;�
4.58
4.50
0.08
1.7%
Photovoltaic Offset
A,' �Y' —
0.00
0.00
—
Compliance Energy Total
&®k 263.78
259.37
4.41
1.7%
♦Ao
Registration Number: �4p® Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-07 09:42:40
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE�OD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
CRF -01
Page 2 of 9
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below. "
Building -level Verifications:
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
• -- None —
Domestic Hot Water System Verifications:'
- None —
ENERGY DESIGN RATING o�
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use - a- Energy Design Rating' Margin Percent Improvement
Total Energy (kTDVlf2-yr)` 299.96 ' �k29555 ' 4.41 1.5%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING -FEATURES INFORMATION
01
02,0`3
04
05 '
06
07
Numiler of Dwelling
Zone Floor Area
Avg. Ceiling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2) Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
Sather Residence
5490 F 1
3
2
1
1
ZONE INFORMATION
01
02 04 03
04
05
06
07
�i
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Typef', HVAC System Name
(ft)
Height
Water Heating System 1
Water Heating System 2
Main
Conditiofieci
CERTIE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xmi
CORF-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (W)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
80d Wall ex
Main
R-13 Wall (W.13.2x6.16)
80
Front
2820
303.8
90
Existing
No
170d Wall ex
Main
R-13 Wall (W.13.2x6.16)
170
Left
3210
347.2
90
Existing
No
260d Wall ex
Main
R-13 Wall (W.13.2x6.16)
260
Back
2820
142.6
90
Existing
No
350d Wall ex
Main
R-13 Wall (W.13.2x6.16)
350
Right
3210
_ 444.5
90
Existing
No
Roof `
Main
Default 1978 to present..
5380
Existing
No
80d Wall
.,'add
R-21 Wall (W.21.2x6.16)
80 ,�
Front
400
90
New
N/A
170d Wall
`, add
R-21 Wall (W.21.2x6.16)
170
Left
600.
4.6
90
New
N/A
260d Wall
add ' ' r
R-21 Wall (W.21.2x6.16)
2604
Back
400
90
New
N/A
Roof 2
add ' .
R-38 Roof Attic
110
New
N/A
ATTIC
01
, 02 " ,
03 '
�C04
05
_06
07
08
09
10
Radiant
Statu
Verified Existing
'Name
Construction .
'Type •oQ
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition-
Attic Main :
Attic RoofMain
VentilatedZ
3
0.1
0.85
No
No
Existi
No
�._
j
ng
Attic add
Attic Roofadd
Ventilated
3
0.1
0.85
No
No
New
No
eN�
♦ �d
Registration Number: �e�Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider:
Report Generated at: 2015-08-07 09:42:40
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis
Input File Name: Sather-JMA-15.xmi
CF*RF-01
Page 4of9
WINDOWS
01
02
03
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Multiplie
Height (ft) r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
3x4.5 ex m
80d Wall ex (Front -80)
-
-- 1
13.5
0.39
0.18
Insect Screen (default)
Existing
No
6x7 ex 7
80d Wall ex (Front -80)
-
- 1
42.0
0.39
0.18
Insect Screen (default)
Existing
No
2.3x7 ex 18
80d Wall ex (Front -80)
-
-- 1
16.1
0.39
0.18
Insect Screen (default)
Existing
No
4x8 ex 23
80d Wall ex (Front -80)
-
- 1
32.0
0.39
0.18
Insect Screen (default)
Existing
No
5x8 ex r
80d Wall ex (Front -80)
-
-- 1
40.0
0.39
0.18
Insect Screen (default)
Existing
No
3.4x6.5 ex gg
80d Wall ex (Front -80)
-
- 1 22.1
0.39
0.18
Insect Screen (default)
Existing
No
5.5x8 ex 22
80d Wall ex (Front -80)
-
-- �1��
44.0
0.39
0.18
Insect Screen (default)
Existing
No
3.4x6.5 ex hh
80d Wall ex (Front -80)
-
- e �1
22.1
0.39
0.18
Insect Screen (default)
Existing
No
5x8 ex s
80d Wall ex (Front -80)
-
-- 1
40.0
0.39
0.18
Insect Screen (default)
Existing
No
4x8 ex 32
80d Wall ex (Front -80)
-
- 1
32.0
0.39
0.18
Insect Screen (default)
Existing
No
2.4x4.5 ex n
170d Wall ex (Left -170)
-
1
10.8
0.39
0.18
Insect Screen (default)
Existing
No
6x8 ex 27
170d Wall ex (Left -170)
-
1
48.0
0.39
0.18
Insect Screen (default)
Existing
No
2.5x4 ex t
170d Wall ex (Left -170)
-
`- 1
10.0
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex w
170d Wall ex (Left -170)
- -- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex ww
170d Wall ex (Left -170)
--
Aw
1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex v
170d Wall ex (Left -170)
��
-- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex vv
170d Wall ex (Left -170)
!!fir--
1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex u
170d Wall ex (Left -170)
1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex uu
170d Wall ex (Left -170) j v -
-- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 1
170d Wall ex (Left -170)x,
-
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 1 2
170d Wall ex (Left -170)
-
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 1 3
170d Wall ex (Left -1 0
-
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
12.8x4 ex h
170d Wall ex (Leftvy'-170)
--
-- 1
51.2
0.39
0.18
Insect Screen (default)
Existing
No
2.8x4 ex c
170d Wall ex Sj of -170)
-
- 1
11.2
0.39
0.18
Insect Screen (default)
Existing
No
4.3x8 ex 11
170d Wali ez��(Left-170)
-
-- 1
34.2
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 30
260d WAW (Back -260)
-
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
6.8x5.8 ex ff
260d W�+"all ex (Back -260)
-
- 1
39.4
0.39
0.18
Insect Screen (default)
Existing
No
2.8x4 ex d
2t6CVNall ex (Back -260)
--
-- 1
11.2
0.39
0.18
Insect Screen (default)
Existing
No
7x4 ex g
�260d Wall ex (Back -260)
-
- 1
28.0
0.39
0.18
Insect Screen (default)
Existing
No
Registration Number: A�i
CA Building Energy Efficiency Staha ds - 2013 Residential Compliance
Registration Datefrime:
Report Version - CF111-07082015-744
HERS Provider:
Report Generated at: 2015-08-07 09:42:40
CERTI�E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD CF*RF-01
Project M1Tame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015 Page 5 of 9
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xm1
2x2 ex f
260d Wall ex (Back -260) -
- 1
4.0
0.39
0.18
Insect Screen (default)
Existing
No
2x2 ex 11
260d Wall ex (Back -260) -
- 1
4.0
0.39 '
0.18
Insect Screen (default)
Existing
No
3.7x8 ex 10
350d Wall ex (Right -350) -
- 1
29.60.39
0.18
Insect Screen (default)
Existing
No
7x6 ex a
350d Wall ex (Right -350) -
- 1
42.0
0.39
0.18
Insect Screen (default)
Existing
No
7x10 ex 2a
350d Wall ex (Right -350) -
-- 1
70.0
0.39
0.18
Insect Screen (default)
Existing
No
7x10 ex2
350d Wall ex (Right -350) -
- 1
70.0
0.39
0.18
Insect Screen (default)
Existing
No
7x10 ex 2a 2
350d Wall ex (Right -350) -
-. 1
70.0
0.39
0.18
Insect Screen (default)
Existing
No
6.7x8 ex 3
350d Wall ex (Right -350) -
- 1
53.6
0.39
0.18
Insect Screen (default)
Existing
No
6x8 ex s
350d Wall ex (Right -350) -
1
48.0
0.39
0.18
insect Screen (default)
Existing.
No
6x7 ex k
350d Wall ex (Right -350) -
--" 1 J 42.0
0.39
0.18
Insect Screen (default)
Existing
No
2x4 ex j
350d Wall ex (Right -350) -
- 1
8.0
0.39
0.18
Insect Screen (default)
Existing
No
2.5x4.5 ex I
350d Wall ex (Right -350) -
--'�
11.3
0.39
0.18
Insect Screen (default)
Existing
No .
1.5x1.5 ex o
170d Wall (Left -170) -
.1
2.3
0.39
0.18
Insect Screen (default)
Existing
, No
1.5x1.5 ex o 2
170d Wall (Left -170) -
- A i 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
®v t
o®
to
Registration Number: ®� % Registration Date/Time:
CA Building Energy Efficiency Stan daar'ds - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider:
Report Generated at: 2015-08-07 09:42:40
a
-
HERS Provider:
Report Generated at: 2015-08-07 09:42:40
CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xm1
CF*RF-01
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
•
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Perimeter
Carpeted
Existing
• Cavity/Frame: no insul. /2x4 Top Choi
Zone ��
Area (ft)
(ft)
2x4 Top Chord of Roof Truss @ 24
Fraction
Heated
Roof Deck., Wood Siding/sheathing/decking
Attic RoofMain
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing. Light Roof (Asphalt Shingle)
No
Existing
No
Covered Slab
addAft
110
• Inside Finish: Gypsum Board
None
Ceilings (below
No
New
No
Cavity/Frame: R-9.1 /2x4
Default 1978 to present..
attic)
Wood Framed Ceiling
'2x4 @ 16 in. O.C.
R11
0.083
Over Floor Joists: R-1.9 insul.
>
Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wail (W.13.2x6.16)
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof T ss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofadd
Attic Roofs
Wood Framed Ceiling
in. O.C9
none
0.644
Roofing: Light Roof (Asphak Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4_@�16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
o
@�
Exterior Finish: Wood
R-21 Wall (W21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
VWA
SLAB FLOORS WIV
01
02
�03
04
05
06
07
08
09
•
Verified
Perimeter
Carpeted
Existing
Name
Zone ��
Area (ft)
(ft)
Edge lnsul. R -value
Fraction
Heated
Status
Condition
Covered Slab ex
Main
5380
286
None
0.8
No
Existing
No
Covered Slab
addAft
110
38
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION W.91
01 �f �` 02 03 04
Quality Insulation Installation (QII)®� Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required ®V Not Required Not Required —
!Ai
Registration Number:
CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-07082015-744
HERS Provider:
Report Generated at: 2015-08-07 09:42:40
CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE CWOD
Project ame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
CF*RF-01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
1 07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
ZE nergy Factor or
r�►� Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction) '
DHW Heater 1
Natural Gas
Small Storage
50
0.61 EF
40000-Btu/hr
0
0
WATER HEATING -,HERS VERIFICATION ?®�
01
02
03 �)
04
05
06
07
Name
Pipe Insulation -
Parallel Piping,
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a te
n/a
n/a
n/a
,, n/a
SPACE CONDITIONING SYSTEMS o®
01
02,
03
04
05
06
07
08
09
Heating System
. Cooling System '
w
��
>
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted off®
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating. and
Heating
Y"�' "
Cooling
Yes
Air Distribution
HVAC Fan
'`490
Existing
No
Cooling System
Component 1
Component 1
System 1
1
all
HVAC - HEATING SYSTEMS
01 02 03
Name �A . Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
o e®
o®�
Registration Number:
CA Building Energy Efficiency Stan daar'ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - C17111-07082015-744
HERS Provider:
Report Generated at: 2015-08-07 09:42:40
CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD ,
Project ame: Sather Residence ation Date/Time: 09:41, Fri, Aug.07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
CFORF-01
Page 8 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
OS 06
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
Yes
No
N/A
—
system
Status
Condition
Verification
HVAC - DISTRIBUTION SYSTEMS
01
02•
03
04
05
06
07
08
09
10
•
OS 06
-
Insulation
Supply Duct
Retu" rn Duct
Verified Duct Design
Name
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
—
Bypass Duct
Status
Condition
Verification
�(LLocation
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
•
N/A
System 1
specified)
$
�
o® d
HVAC DISTRIBUTION - HERS VERIFICATION
Q
01
02 03 04
Name
�� Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1
61 0.52459 1
01.
02
03
04
OS 06
-
- Duct Leakage
Duct Leakages
Verified Duct Design
Name
Verification
Target (0/,d)
Verified Verified Duct Location
Return Supply
Air Distribution System 1 -hers -dist
N/A
.—�
—
— —
IAQ (Indoor Air Quality) FANS
01 02 �03 04 05 .
Name IAQ CFM o�{�a IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
COOLING VENTILATION
, ®;to
01
02 03 04
Name
�� Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1
61 0.52459 1
o®
Registration Number: 44 ® Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider: k
Report Generated at: 2015-08-07 09:42:40
' CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD CFORF-01
Project ame: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Page 9 of 9
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xm1
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:,
Documentation Author Signature:
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc, -
8/7/2015
Address:
CEA/HERS Certification Identification (If applicable):
77-085 Michigan Drive -
City/State ip
al'm Desert; CA 92211
Phone:.
(76,0) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT�-
I certify the following under penalty of perjury, under the laws of the State of California og�
1. 1 am eligible under Division 3 of the Business and Professions,Code to accept responsibility for theme building design identified on this Certificate o� Compliance.
2. I certify that the energy features and performance specifications identified on this Certificate of,Compliance conform to the requirements of Title/24, Part 1 and Part 6 of the California Code of
Regulations.
/n
3. The building design features or.system design features identified -on this Certificate of Compliance are consistent with the information provided other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency�for approval with this building permit application: / l
Responsible Designer Name: 41:�
Responsible Designer Signature:
JMA Architecture and Engineering. ,�Aft
Company: V
Date Signed: L
JMA Architecture and Engineering
Address: w ��
License:
73-995 El Paseo Suite 203
City/State/Zip:
Phone: -
Palm Desert, CA 92260
(760) 346-6155
®AV
Registration Number: ® Registration Date/Time: HERS Provider: '
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFlR-07082015-744 Report Generated at: 2015-08-07 09:42:40
•
C`
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Sather Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
$/7/2015
Project Address
77-330 Vista Rosa La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,490
Addition
110
# of Units
1
INSULATION
Construction Type
Area
Cavi(ft) Special Features Status
Roof Wood Framed Attic R11 5,380 Existing
Wall Wood Framed R 13 10,822 Existing
Slab Unheated Slab -on -Grade - no insulation 5,380 Perim = 286' Existing
Demising Wood Framed - no insulation 735 Existing
Roof Wood Framed Attic R38 110 New
Wall Wood Framed R 21 1,395 New
Slab Unheated Slab -on -Grade -
no insulation 110 Perim = 38' New
FENESTRATION Total Area: 1,243 Glazin Percentage: 22.6T, New/Altered Average U -Factor: 0.00
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Front (E) 303.8 0.390
0.18 none none Bug Screen Existing
Left (S) 351.8 0.390
0.18 none none Bug Screen Existing
Rear (IM 142.6 0.390
0.18 none none Bug Screen Existing
Right (N) 444.5 0.390
0.18 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
4 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Enerq yPro 6.7 by EnemySoft User Number: 6712
Run Code: 2015-08-07T09:43:19 /D:
Pae 12 of 26
L
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
corn liance
approach used. Exceptions may apply, Review the respective code section or more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-11l(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFI R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§ I50.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150 .0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)1A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.OQ)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ I50.0Q)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
4
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ ] 50.0(n)l :
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ ] 50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ ] 50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)l0:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)]2:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow>_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
4
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)]A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§I50.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§I50.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ I50.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in ' 150.0(k)2.
§ ] 50.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ ] 50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ ] 50.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
4
2013 Low -Rise Residential Mandatory Measures Summary
7�
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, § 130.2, §130.4, §140.7 and § 141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2 § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, §130.2, §130.4, §140.7 and § 141.0.
§ I50.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 § 130.0, § 130.1 § 130.4, § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §110.10 b through §110.10 e .
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §I 10.10(d).
The solar zone shall have'a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
7�
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
ather Residence
Date
8/7/2015
System Name
HVAC
Floor Area
5,490
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
4
COIL
CFM
Total Room Loads 7,726
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 824
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 89,000
108,243
7,841 3,171
118,792
Total Output Btuh 356,000
0
Output Btuh/s ft 64.8
9,178
8,440
Cooling System
0
0
Output perSystem 57,800
35,863
14,926 824
39,445
Total Output Btuh 231,200
0
9,178
1 162,464 22,768
0
Total Output Tons 19.3
8,440
Total Output Btuh/s ft 42.1
Total Output s ft/Ton 284.9
175,116
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
8,000
Existing HVAC 166,308 32,452
356,000
Airflow cfmis ft
1.46
Airflow cfm/Ton
415.2
Outside Air %
10.3%
Total Adjusted System Output 1 166,308 32,452
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK Aug 3 PM
356,000
Outside Air cfmis ft 0.15
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
824 cfm
71 OF
66 OF 108 OF _ 108 OF
mom
Heating Coil Supply Fan
107 OF
8,000 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/63°F 75/63°F 56/55°F
Outside Air
824 cfm Supply Fan Cooling Coil 57 / 55 OF
8,000 cfm
58.1 % ROOM
71/61°F70/60°F
U�E3
EnergyPro 6.7 by EnergySoft
User Number: 6712 Run Code: 2015-68-07T09:43:19 /D: Page 17 of 26
•
ROOM HEATING PEAK LOADS
Project Name78/7/2015
Sather Residence
ate
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Main
Floor Area 5,380.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U -Value
5,380.0 X 0.0790
10,821.9 X 0.1020
1,238.1 X 0.3900
perim = 286.0 X 0.7300
625.0 X 0.3560
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to another room
X 5,380 X 9.00 X 0.266
Area Ceiling Height ACH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
46 =
46 =
46 c
46 =
0 =
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total
/60] X 46
AT
Btu/hr
Default 1978 to present...
19,551
R-13 Wall (W. 13.2x6.16)
50,776
ex non metal Window. 39.18
22,212
Slab -On -Grade
9,604
'R-0 Interior Wall
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
102,143
= 10,515
TOTAL HOURLY HEAT LOSS FOR ROOM 112,658
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-07T09:43:19 /D: Page 19 of 26
•
C
•
ROOM HEATING PEAK LOADS
Project Name
Sather Residence
Date
81712015.
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Addition Residence
Floor Area 110.0 ftz
Indoor Dry Bulb Temperature 72 OF,
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X 0.0260
AT OF
X 46
X 46
X 46
X 46
X 0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page Total
/60] X
AT
Btu/hr
= 132
= 4,429
= 83
= 1,276
0 0
=
=
=
=
=
=
=
=
=
=
=
=
=
-
=
=
=
5,919
46 = 215
R-38 Roof Attic
110.0
R-21 Wall (W.21.2x6.16)
1,395.4
X
0.0690
ex non metal Window.39.18
4.6
X
0.3900
Slab -On -Grade
pen .m = 38.0
X
0.7300
"R-0 Interior Wall
110.0
X
X
0.3560
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room
9.00 X 0.266
Ceiling Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 110 X
Area
TOTAL HOURLY HEAT LOSS FOR ROOM 6,134
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 ID: Page 20 of 26
1�
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Sather Residence 8/7/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Existing Main
Outdoor Dry Bulb Temperature
112 OF
Floor Area
5,380.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Dailv Ranae:
34 OF
ODaaue Surfaces
Default 1978 to present...
R-13 Wall (W..13.2x6.16)
R-13 Wall (W. 13.24.16)
R-13 Wall (W. 13.24.16)
R-13 Wall (W.13.2x6.16)
-R-0 Interior Wall
Orientation
(►M
(E)
(S)
(tM
(N)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
5,380.0
0.0790
56.0
2,516.2
0.1020
32.1
Z862.8
0.1020
27.1
2,677.4
0.1020
32.6
2,765.5
0.1020
29.0
625.0
0.3560
0.0
0.0
14.5
40.0
24.1
0.0
14.5
22.1
24.1
0.0
14.5
44.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
3x4.5 ex m
6x7 ex 7
2.3x7 ex 18
4x8 ex 23
5x8 ex r
3.46.5 ex gg
5.54 ex 22
3.46.5 ex hh
5x8 ex s
Orientation
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
Shaded Unshaded
Area
X
X
X
X
-X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
14.5
13.5
24.1
0.0
14.5
42.0
24.1
0.0
14.5
16.1
24.1
0.0
14.5
32.0
24.1
0.0
14.5
40.0
24.1
0.0
14.5
22.1
24.1
0.0
14.5
44.0
24.1
0.0
14.5
22.1
24.1
0.01
14.5
40.0
24.1
Page Total
Btu/hr
23,801
8,241
7,917
8,891
8,180
57,
Btu/hr
325
1,011
388
770
963
532
1,059
532
6,
Internal Gain Btu/hr-
Occupants 16.1 Occupants X 245 Btuh/occ. = 3,954
Equipment 5,380 Floor Area . X 0.50 w/sgft = 9,181
Infiltration: 1.064 X 0.94 X 221.90 X 42 = 9,275
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104.656
Latent Gain Btu/hr
Occupants Occupants X 155 Btuh/occ. = 2,502
Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 = 5,183
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR
I EnergyPro 6.7 by EnemySoR User Number. 6712 Run Code: 2015-08-07709:43:19 ID: Paoe 21 of 26 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
' Sather Residence 8/7/2015
ROOM INFORMATION DESIGN CONDITIONS'
Room Name Existing Main Outdoor Dry Bulb Temperature 112 OF
Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temuerature 70 OF Outdoor Dailv Ranae: 34 OF
17,
Surfaces
Orientation
Area U -Factor CLTD'
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another. room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
4x8 ex 32
2.4x4.5 ex n
6x8 ex 27
2.5x4 ex t
1.5x1.5 ex w
1.5x1.5 ex ww
1.5x1.5 ex v
1.5x1.5 ex w
1.5x1.5 ex u
Oripntatinn
(E)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Shaded
Area
X
X
X
X
X
X
X
X
X
Unshaded
Area
+ 32.0
X
X
X
X
X
X
X
X.
X
0.0
=
=
=
=
=
=
=
_
-
24.1
c
=
0.0
+
+
+
+
+
10.8
15.4
r 0.0
48.0
X
X
X
X
X
X
15.4
=
=
=
=
=
=
0.0
10.0
15.4
0.0
2.3
15.4
0.0
2.3
15.4
0.0
+ 2.3
+ 2.3
+1' 2.3
15.4
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another. room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
4x8 ex 32
2.4x4.5 ex n
6x8 ex 27
2.5x4 ex t
1.5x1.5 ex w
1.5x1.5 ex ww
1.5x1.5 ex v
1.5x1.5 ex w
1.5x1.5 ex u
Oripntatinn
(E)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Shaded
Area
GLF
X 14.5
X 14.5
X 14.5
X 14.5
X 14.5
X 14.5
X 14.5
X 14.5
X1 14.5
Unshaded
Area
+ 32.0
GLF
0.0
X
X
24.1
c
=
0.0
+
+
+
+
+
10.8
15.4
r 0.0
48.0
X
X
X
X
X
X
15.4
=
=
=
=
=
=
0.0
10.0
15.4
0.0
2.3
15.4
0.0
2.3
15.4
0.0
+ 2.3
+ 2.3
+1' 2.3
15.4
0.0
15.4
0.0
X1
15.4
-
Page Total
Btu/hr
Btu/hr
770
741
154
35
Internal Gain Btu/hr
Occupants 16.1 Occupants X 245 Btuh/occ. = 3,954
Equipment - 5,380 Floor Area X 0.50 w/sgft = 9,181
Infiltration: 1.064 X 0.94 X. 221.90 X 42 9,275
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656
Latent Gain Btu/hr
Occupants 1fi1 Occupants X 155 Btuh/occ. = 2,502
Infiltration: 4.771 X 0.94 X . 221.90 X 0.00523 = 5,183
Air Sensible CFM . ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2015-08-07T09:43:19
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Sather Residence 8/7/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing Main Outdoor Dry Bulb Temperature 112 OF
Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF
ue Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
0
=
=
=
Btu/hr
0.0
14.5
2.3
15.4
35
0.0
14.5
56.0
15.4
864
0.0
14.5
56.0
15.4
864
0.0
14.5
56.0
15.4
864
0.0
14.5
51.2
15.4
790
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
1.5x1.5 ex uu
7x8 ex 1
7x8 ex 1
7x8 ex 1
12.8x4 ex h
2.8x4 ex c
4.3x8 ex 11
7x8 ex 30
6.8x5.8 ex ff
Orientation
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(K9
(tM
Btu/hr
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X1
GLF
=
=
=
=
=
0
=
=
=
Btu/hr
0.0
14.5
2.3
15.4
35
0.0
14.5
56.0
15.4
864
0.0
14.5
56.0
15.4
864
0.0
14.5
56.0
15.4
864
0.0
14.5
51.2
15.4
790
0.0
14.5
11.2
15.4
173
0.0
14.5
34.2
15.4
528
0.0
14.5
56.0
24.8
1,387
0.0
14.5
1 39.4
24.8
976
Page Total
6,482
Internal Gain Btu/hr
Occupants 16.1 Occupants X 245 Btuh/occ. 3,954
Equipment 5,380 Floor Area X 1 0.50 w/sgft = 9,181
Infiltration: 1.064 X 0.94 X 221.90 X 42 = 9,275
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104.6561
Latent Gain Btu/hr
Occupants 16.1 Occupants X 155 Btuh/occ. = 2,502
Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 = 5,183
Air Sensible CFM ELA AW
AL HOURLY LATENT HEAT GAIN FOR ROOM
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Sather Residence 8/7/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing Main Outdoor Dry Bulb Temperature. 112 OF
Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF
Surfaces Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
X
X
X
X
X
X
X
X
X
24.8
=
=
=
=
=
=
=
=
=
0.0
14.5
24.8
0.0
14.5
24.8
0.0
14.5
24.8
0.0
14.5
20.3
0.0
.14.5
20.3
0.0
14.5
20.3
Page Total L
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF' Area GLF
2.8x4 ex d
7x4 ex g
2x2 ex f
2x2 ex J
3.7x8 ex 10
7x6 ex e
7x10 ex 2a
7x10 ex2
7x10 ex 2a
Page Total
r
Internal Gain
Occupants 16.1 _Occupants X 245 Btuh/occ.
Equipment 5,380 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.94 X 221.90 X 42 =
Air Sensible CFM ELA AT
Btu/hr
Btu/hr
277
694
99
99
600
851
1,419
1,419
1,419
6,87
Btu/hr
1 9,1811
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656
r
Latent Gain
Occupants 161 Occupants X 155 Btuh/occ.
Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 =
Air Sensible CFM ELA AW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Btu/hr
1 5,1831
LEnemyPro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 ID: Page 24 of 26
0.0
X
X
X
X
X
X
X
X
X
114.5
+g
+
+
+,
+
+"
+
+
+
X
X
X
X
X
X
X
X
X
24.8
=
=
=
=
=
=
=
=
=
0.0
14.5
24.8
0.0
14.5
24.8
0.0
14.5
24.8
0.0
14.5
20.3
0.0
.14.5
20.3
0.0
14.5
20.3
0.0
14.5
20.3
0.0
14.5
20.3
Page Total
r
Internal Gain
Occupants 16.1 _Occupants X 245 Btuh/occ.
Equipment 5,380 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.94 X 221.90 X 42 =
Air Sensible CFM ELA AT
Btu/hr
Btu/hr
277
694
99
99
600
851
1,419
1,419
1,419
6,87
Btu/hr
1 9,1811
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656
r
Latent Gain
Occupants 161 Occupants X 155 Btuh/occ.
Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 =
Air Sensible CFM ELA AW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
Btu/hr
1 5,1831
LEnemyPro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 ID: Page 24 of 26
C
C �
J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Sather Residence
8/7/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Existing Main
Outdoor Dry Bulb Temperature
112 OF
Floor Area
5,380.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
6.7x8 ex 3
(N) 0.0 X 14.5 +
53.6 X
20.3 =
1,086
6x8 ex s
(N) 0.0 X 14.5 +
48.0 X
20.3 =
973
6x7 ex k
(N) 0.0 X 14.5 +
42.0 X
20.3 =
851
2x4 ex j
(N) 0.0 X 14.5 +
8.0 X
20.3 =
162
2.5x4.5 ex I
(N) 0.0 X 14.5 +
11.3 X
20.3 =
229
X +
X
X +
X
=
X +
X
=
X 1 +1
X
=
Page Total
3,302
Internal Gain
Btu/hr
Occupants
16.1 Occupants X 245
Btuh/occ.
=
3,954
Equipment
5,380 Floor Area X 0.50
w/sgft
=
9,181
Infiltration: 1.064
X 0.94 X 221.90. X 42 =
9,275
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
104,656
Latent Gain
Btu/hr
Occupants
Occupants X 155
Btuh/occ.
=
2,502
Infiltration: 4,771
X 0.94 X 221.90 X 0.00523 =.
5,183
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2,502
EnergyPro 6.7 by EneMySoft
User Number: 6712 RunCode: 2015-08-07T09:43:19 /D:
Page 25 of 26
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name781712015
ate
Sather Residence
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Addition Residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
110.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
W 110.0 X 0.0260
X
56.0 =
160
R-21 Wall (W.21.2x6.16)
(E) 400.0 X 0.0690
X
32.1 =
886
R-21 Wall (W.21.2x6.16)
(S) 595.4 X 0.0690
X
27.1 =
1,114
R-21 Wall (W.21.2x6.16)
(tA✓) 400.0 X 0.0690
X
32.6 =
899
'R-0 Interior Wall
110.0 X 0.3560
X
0.0 =
0
X
X
-
X
X
=
X
X
=
X
X I=
Page Total
3,059
Items shown with an asterisk (')
denote conduction through an interior surface to another room. +
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
1.5x1.5 ex o
(S) 0.0 X 14.5 +
2.3
X 15.4 =
35
1.5x 1.5 ex o
(S) 0.0 X 14.5 +
2.3
X 15.4 =
35
X +
X =
i
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X + I
XI =
-
Page Total
71
Internal Gain
Btu/hr
Occupants
0.3 Occupants X 245
Btuh/occ.
=
81
Equipment
110 Floor Area X 0.50
w/sgft
=
188
Infiltration: 1.064
X 0.94 X 4.54 X 42 =
190
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
3,588
Latent Gain
Btu/hr
Occupants
0 3 Occupants X 155
Btuh/occ.
=
51
Infiltration: 4,771
X 0.94 X 4.54 X 0.00523 =
106
Air Sensible
CFM ELA AW
i TOTAL HOURLY LATENT HEAT GAIN FOR ROOM.
51
Ene Pro 6.7 by EnemySoft
User Number.- 6712 RunCode: 2015-08-07709:43:19 ID:
Page 26 of 26
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IWOD
Project Name: Sather Residence IW
culation DatelTime: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis
Input File Name: Sather-JMA-15.xml
C*RF-01
Page 1 of 9
GENERAL INFORMATION
01 Building Complies witFiComputer.PerformA-, ce 44m,Q
01
Project Name Sather Residence
03 This building incorporates one or�A Spec alF eatur�es shhow;—n l elow
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 77-330 Vista Rosa
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 80
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 5490
15
Number of Zones 2
16
Slab Area (ft2) 5490
17
Number of Stories 1
18
Addition Cond. Floor Area 110
19
Natural Gas Available Yes
20
Addition Slab Are0(ie) 110
21
Glazing Percentage (%) 22.6%
COMPLIANCE RESULTS ',%�'
01 Building Complies witFiComputer.PerformA-, ce 44m,Q
02 This building incorporates' features that require fiel8 est ng and/or verifficat by certiI' dl HERS ater u dei the supervision of a CEC-approved HERS provider.
em... �
03 This building incorporates one or�A Spec alF eatur�es shhow;—n l elow
06
07
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-08-07 09:42:47
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
11.90
11.24
0.66
5.5%
Space Cooling
247.30
243.63
3.67
1.5%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
4.58
4.50
0.08
1.7%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
263.78
259.37
4.41
1.7%
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-08-07 09:42:47
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD CRF-01Project Name: Sather Residence ation Date/Time: 09:41, Fri, Aug 07, 2015 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
— None —
Domestic Hot Water System Verifications:
—None --
k
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
;
CERTI E OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE 4kOD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
CF*RF-01.
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft).
Tilt
(deg) '
Status
Verified
Existing
Condition
80d Wall ex _
Main
R-13 Wall (W.13.2x6.16)
80
Front
2820
303.8
90
Existing
No
170d Wall ex .
Main
R-13 Wall (W.13.2x6.16)
170
Left
3210
347.2
90
Existing
No
260d Wall ex
Main
R-13 Wall (W.13.2x6.16)
260
Back
2820
142.6
90
Existing
No
350d Wall ex
Main
R-13 Wall (W.13.2x6.16)
350
Right
3210
444.5
90
Existing
No
Roof
Main
Default 1978 to present..
5380
Existing
No
80d Wall
add
R-21 Wall (W.21.2x6.16)
80
Front
400
90
- New
N/A
170d Wall
add i
R-21 Wall (W.21.2x6.16)
170
Left
600
'4.6
90
New
N/A
260d Wall
add' 'E
R-21 Wall (W.21.2x6.16)
260
Back
400
90
New
N/A
Roof 2
add.-? y.
R-38 Roof Attic
110
New
N/A
#1 4 3 R
ATTIC •�. U -.--j
01
.. y 02. -
03
04 `
3 `
06
07
OS
09
10
Name
Consttion
Type
�y Ro f Rise
Roof Refle ctance
'
RoofjE mittan
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic Main
Attic RoofMaini
Ve entilated a
g 3
> K.
0.16'
0; 85
No
No
Existi
ng
No
Attic add
Attic Roofadd
Ventilated
3
0.1
0.85
No
No
New
No
Registration Number: 215-Ao219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47
CERTI'VE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Ca
Project 'VE
Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis
Input File Name: Sather-JMA-15.xml
C*RF-01
Page 4 of 9
WINDOWS
01
02 03
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth) Width(ft)
Multiplie
Height (ft) r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
3x4.5 ex m
80d Wall ex (Front -80) -
- 1
13.5
0.39
0.18
Insect Screen (default)
Existing
No
6x7 ex 7
80d Wall ex (Front -80) -
- 1
42.0
0.39
0.18
Insect Screen (default)
Existing
No
2.3x7 ex 18
80d Wall ex (Front -80) -
-- 1
16.1
0.39
0.18
Insect Screen (default)
Existing
No
48 ex 23
80d Wall ex (Front -80) -
- 1
32.0
0.39
0.18
Insect Screen (default)
Existing
No
5x8 ex r
80d Wall ex (Front -80) -
- 1
40.0
0.39
0.18
Insect Screen (default)
Existing
No
3.4x6.5 ex gg
80d Wall ex (Front -80) -
-- 1
22.1
0.39
0.18
Insect Screen (default)
Existing
No
5.5x8 ex 22
80d Wall ex (Front -80) -
- 1
44.0
0.39
0.18
Insect Screen (default)
Existing
No
3.4x6.5 ex hh
80d Wall ex (Front -80) -
- 1
22.1
0.39
0.18
Insect Screen (default)
Existing
No
5x8 ex s
80d Wall ex (Front -80) -
- 1
40.0
0.39
0.18
Insect Screen (default)
Existing
No
48 ex 32
80d Wall ex (Front -80) -
- 1
32.0
0.39
0.18
Insect Screen (default)
Existing
No
2.44.5 ex n
170d Wall ex (Left -170), -
- 1
10.8
0.39
0.18
Insect Screen (default)
Existing
No
6x8 ex 27
170d Wall ex (Left -170),#'' --•� %
A F
y �{3¢ 1 '��(yr4-8.0
�!' ff
0.39
1 i ti 0_
0.18
9 i.418
Insect Screen (default)
Existing
No
2.5x4 ex t
170d Wall (Left -170k F 1e kV
. -- '1 1
1Or0�
0.39 y Ft0 18
Insect Screen (default)
Existing
No
1.5x1.5 ex w
'. a^ t ' 'ta�+•ex b.i "s snw" 4.rn.xd11w/
170d Wall ex (Left -170) _-_ _ - _ 1 _
'F r
2.3
X y i
0.39 ' 0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex ww
"'170d Wall ex (Left,170) -r C
i `M 1'QJ
I:Z3
0�39 �
01'8
Insect Screen (default)
Existing
No
1.5x1.5 ex v
170d Wall ex (Left -170) -
- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex vv
170d Wall ex (Left -170) --
- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex u
170d Wall ex (Left -170) -
- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex uu
170d Wall ex (Left -170) -
- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 1
170d Wall ex (Left -170) --
-- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 1 2
170d Wall ex (Left -170) -
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 1 3
170d Wall ex (Left -170) -
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
12.8x4 ex h
170d Wall ex (Left -170) -
- 1
51.2
0.39
0.18
Insect Screen (default)
Existing
No
2.8x4 ex c
170d Wall ex (Left -170) -
- 1
11.2
0.39
0.18
Insect Screen (default)
Existing
No
4.3x8 ex 11
170d Wall ex (Left -170) -
- 1
34.2
0.39
0.18
Insect Screen (default)
Existing
No
7x8 ex 30
260d Wall ex (Back -260) -
- 1
56.0
0.39
0.18
Insect Screen (default)
Existing
No
6.8x5.8 ex ff
260d Wall ex (Back -260) -
- 1
39.4
0.39
0.18
Insect Screen (default)
Existing
No
2.8x4 ex d
260d Wall ex (Back -260) -
- 1
11.2
0.39
0.18
Insect Screen (default)
Existing
No
7x4 ex g
260d Wall ex (Back -260) -
_- 1 28.0
0.39
0.18 -
insect Screen (default)
- Existing -- -
- -No -- -
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
CF.RF-01
Page 5 of 9
2x2 ex f
260d Wall ex (Back -260) -
- 1
4.0
0.39
0.18
Insect Screen (default)
Existing
No
2x2 ex jj
260d Wall ex (Back -260) -
- 1
4.0
0.39
0.18
Insect Screen (default)
Existing
No
3.7x8 ex 10
'350d Wall ex (Right -350) -
- 1
29.6
0.39
0.18
Insect Screen (default)
Existing
No'
7x6 ex a
350d Wall ex (Right -350) -
- 1
42.0
0.39
0.18
Insect Screen (default)
Existing
No
7x10 ex 2a
350d Wall ex (Right -350) -
- 1
70.0
0.39
0.18
Insect Screen (default)
Existing
No
7x10 ex2
350d Wall ex (Right -350) -
- 1
70.0
0.39
0.18
Insect Screen (default)
Existing
No
7x10 ex 2a 2
350d Wall ex (Right -350) -
- 1
70.0
0.39
0.18
Insect Screen (default)
Existing
No
6.7x8 ex 3
350d Wall ex (Right -350) -
- 1
53.6
0.39
0.18
Insect Screen (default)
Existing
No
6x8 ex s
- 350d Wall ex (Right -350) -
- 1
48.0
0.39
0.18
Insect Screen (default)
Existing
No
6x7 ex k
Mcl Wall ex (Right -350) -
-- 1_
42.0
0.39
0.18 ,
Insect Screen (default)
Existing
No
2x4 ex j
350d Wall ex (Right -350) -
- 1
8.0
.0.39
0.18 -
Insect Screen (default)
Existing
No
2.5x4.5 ex I
350d Wall.ex (Right -350) -
- 1
11.3
0.39
0.18
Insect Screen (default)
Existing
No
1.5x1.5 ex o
170d -Wall (Left -170) -
- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No -
1.5x1.5 ex o 2
17l)djWall,(Left-170) - „17
- 1
2.3
0.39
0.18
Insect Screen (default)
Existing
No
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47
R
CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE !-IOD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
C*RF-01
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
286
None
0.8
No
Existing
No
• Cavity/Frame: no insul. /2x4 Top Chrd
add
110
38
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck. Wood Siding/sheathing/decking
Attic RoofMain
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Default 1978 to present..
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R11
0.083
Over Floor Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
• Exterior Finish: Wood
R-13 Wall (W.13.2x6.16) -
Exterior Walls =
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
1114
Cavity / Frame: no insul. / 2x4 Top Chrd
-
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofadd
Attic Roofs:' - '„
ti Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
--.-•- -
Inside Finish: Gypsum Board
Ceilings (below
,-^
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic) ,
Wood Framed;Ceiling
.2x4f@11.6 inw!O Cox
R 381
0.025
Over Floor Joists: R-28.9 insul.
f ,
Dam
Inside Finish: Gypsum Board
Cavity /Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Fram�!,Wall
<2x6 @ 16�;in. Qom.
!R 21-1 1
Ot066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (f:2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab ex
Main
5380
286
None
0.8
No
Existing
No
Covered Slab
add
110
38
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required —
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47
CERTI#E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
CF.*RF-01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61 EF
40000-Btu/hr
0
0
s
WATER HEATING - HERS VERIFICATION r �
01
t' it 02
03
04 05
06
07
It
Name
T^ 'A�-<....-
Pipe Insulation, - "" '
~ Parallel Piping
Compact Distribution Point -of Use
Recirculation withRecirculation
Manual Control
with
Sensor Control
DHW Sys 1
n/a—,-
n7a°%a
w n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS 0-wo,a 1
01
02 ,(<`
'�*_A03 H E
RS 044
i V051,
) E06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
CoolingAir
Yes
Distribution
HVAC fan
5490
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 -
CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
CFORF-01-
Page 8 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05,
06
07
07
08
Efficiency
10
Multi -speed
OAV". AVtw A
Verified'Dutaocition.
ct
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
I
SplitAirCond - Split air conditioning
10
12
I
Yes
No
N/A
I
I system
Status
Condition
I
I
I I
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target - N -0 -ft
OAV". AVtw A
Verified'Dutaocition.
ct
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage*
R -value-
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
ExistingNo
N/A
System 1
1
�.. specified)
F
.
HVAC DISTRIBUTION - HERS VERIFICATION
t1tK.5
FKUVIULK
01
01
03 04 .05
03
04
05 06
Name
Duct Leakage---,
- ,Verification
Duct Leakage
Target - N -0 -ft
OAV". AVtw A
Verified'Dutaocition.
ct
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
Aft-
IAQ (indoor Air Quality) FANS Y'
t1tK.5
FKUVIULK
01
02
03 04 .05
Name
IAQ CFM
IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam 1AQVentRpt
0
Default 0 Not Required
.COOLING VENTILATION
01 02 03 04
Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1 61 0.52459 1
Registration Number: 215-AO219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47
CERTI E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD CFJRF,01`
Project IJame:.Sather Residence Calculation DatefTime: 09:41, Fri, Aug 07, 2015 Page 9 of 9
Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
%rxrri.$'c6'i-
Tim Scott
Company:
Signature Date:
.Scott Design and Title 24, Inc.
2015-08-07 09:52:23
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive,
City/State/Zip:
Phone:
Palm Desert, CA 92214
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
1 certify the following under penalty of pedury, under the laws of the State of California
1. I am eligible under Division 3 of the Business ;and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and perfoiniance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or systemdesign features ide itified_on-this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans aril specifications submitted "fie enforcement agencyr approval with this.,building permit application.
Responsible Designer Name: ' F
t
(Responsible Designer Sig ature`. .
Tim ScottLEIB'
Company:
Date Signed: y,
Scott Design and Title 24, Inc.
2015-08-07 09: 2`23
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
r
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-07 09:42:47