Loading...
BRES2015-031378-495 CALLE TAMPICO } LA QUINTA, CALIFORNIA 92253 4 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2015-0313 Property Address: 77330 VISTA ROSA APN: 658220029 Application Description: SATHER GLEN & ANN CLOSET ADDITION Property Zoning: Application Valuation: $8,888.00 Applicant: JMA ARCHITECTURE, INC. P.O. BOX 778 PALM DESERT, CA 92261 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: ��B License No.: 541336 Date:, 1 r�-1' Contractor: OWNER -BUILDER DECLARATI N I hereby affirm under penalty of perjury that I am exempt rom the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a - permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason f Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/21/2015 Owner: GLENN & ANN SATHER 77330 VISTA ROSA LA QUINTA, CA 92253 Contractor: RON SAWYER CONSTRUCTION INC 78525 AVENUE 41 BERMUDA DUNES, CA 92203 (760)200-0893 Llc. No.: 541336 WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wor r which this permit is issued. I have and will maintain workers%compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued! My workers' compensation insurance carrier and policy number are: Carrier: _ • Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if houId become subject to the workers' compensation provisions of Section o he Labor Code, I shall forthwith comply with those provisions. Dater �- (� Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSA N COV RAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIE CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. - 1..Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as'a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city r upon the above-mentioned property for inspection purposes. ( C� Date: " �1' (J Signature (Applicant or Agent): i xF: DESCRIPTION r ACCOUNT f {CITY. c ANiOUNTy c%�.¢ PAID sk c: 1PAIDDATEh: ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 = 0 $62.36 $62.36 9/21/15 E� -fi.a �' t o 4 Y j5 k..64 PAID:BY Y: �4 Y{Eto METHOD c+ RECEIPT #4 CHECK # a V 3 'CLTD BY E RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA p § § L 9 -tE1 .Q.q .' £' DESCRIPTIONriv �cA000UNT�1 d i E.R` iE-X 'Ys` QTY 'f t^h. AMOUNTF PAIp { PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $17.40 9/21/15 PAID BY y s MEO T „ -RECEIPT#''� CHECK# CLTD BY x RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA `DESCRIP..TION? ACC0.l1NTs'QTY.fj AMOUNT x� PAIDffi PAID DATE+ P r4 h 6 r . ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 9/21/15 PAIDBYxNNAP._x� METHODsK�� RECEIPT#z ` �%<d'CHECK#ECLTUBYx. r c�..,a4 1 > v<r#. y RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA :DESCRIP,TION wACCOUNT F AMOUNT s PAID 5 . PAID DATE?. _kgTY�s ADDITION, FIRST 100 SF PC . 101-0000-42600 0 $171.14 $171.14 9/21/15 "..r PAID_BY c RECEIPT #� X4s CHECK # V; CLTD BY�'. s r"='�aµMETHOD . ? cis ;+ § RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA Total Paid for ADDITION: $371.73 $371.73 SCRIPTI "--ACOUNT fir "AMOUNTi 0462;x`.. PAID;DATEDE .. _ ?,� HOURLY PLAN CHECK -YES 101-0600-42600 2 $140.00 $140.00 9/21/15 s * BY4 METHOD RECEIPT ;# ' CHECK # CLTD BY n .,PAID y.c $,.,�.. t o g� RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA DESCRIPTIONtbz <q„; Y s ACCOUNTy QTY AMOUNT AID PAID DATE; § + 8. *Ppl , , HOURLY PLAN CHECK - YES 101-0000-42600 1 $70.00 $70.00 9/21/15 ,�-a,y } s PAIDtiBY M ETHOD n # �, =x b..a .:. CHECK #.: .: ” CLTD BY h { z r. <RECEIPT z c RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 $210.00 " " DESCRIPTION' b a ` ">> :QTY} '. E." AMOUNTc ` � s T �4PAID z Y DATE` ,i ,ACCOUNT& , ,. ,PAID BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 9/21/15 t ':" e •S :+'� s� a PAID BY 'ice 1 ai ? METHOD F q RECEIPT M EA 'Y' ,. Q 'Y r, CHECK # J CLTD BY _x 3 Cf q. i.�:-r s .z ...,,.: � ?o� `LY' .i4=� a.3.h, e r �.. ss �' RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 '� ACCOU Ts<x, fy UN PA(D PAIDD.DATEcDESCRIPTION � , rwE •'r .. R RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 9/21/15 „iqt $ PAID'BYr Ew � METHOD'° u RECEIPT ## < CHECK # ; 'CLTD BY . , ,£ r Y , RON SAWYER CONSTRUCTION INC CHECK '.M11226 27320 MFA bESCRIP,TION : ;'4 :ACCOUNT b; =QTY + AMOUNT k $ c PAID PAID DATE: ,. ��� s .:I RESIDENTIAL, FIRST 1,000SF, PC- 101-0000-42600 0 $47.86 $47.86 9/21/15 „c c PAID BY ;f 71 METHOD Cd RECEIPT i CHEGK # e " CLTQ BY# Y # RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 �.DESCRIPTIUNttrX�e,� ` Xp=ACCOUNTk 'Q ='z�AMOUNT y, "FU PAID PAID;DA E -ri. �: ;- x'�'; F. ,"' x}'* ,� x ...ros its #., $.y',{+d,m cer 2+n 'CEi x" Y',i b, x lw.v' i pj e/ci APPLIANCE REPAIR/ALTERATION 101-0000-42402 .0 $12.09 $12.09 9/21/15 PATO BYE *z. -z• -y?; TL"' d ri.a METHOD ,.,,+iMEi - RECEIPT # x CHECK # `, CLTD BYE ti §ivR�s fx -e -:.. n :s :%. �. ma x. -:-v: '. n .r +.. a - v - x•.. r.. n rot +. •:+x rn' Wt RON SAWYER CONSTRUCTION INC CHECK MR226 27320 MFA r �ta-x 7+ ,__ z-+ gs. DESCRIPTION -:+€^" ,�. ,:sr . i4rs. v .,,„ N.t�` ACCOUNTAMOUNTO", •4; �-.:. »g.,, z - •. .. DATE; .. A-4, a Y xPAlf) ,`';'PAID APPLIANCE REPAIR/ALTERATION PC , 101-0000-42600 0 $4.83 $4.83 9/21/15 '� PAID BY? 33 +s «� � ` # 4a ¢� CHECK # v. BY'i 3w vtxMETHOD' �n�ax;YRECEIPT yCLTD RON SAWYER CONSTRUCTION INC CHECK MR226 27320 r MFA Total Paid for MECHANICAL: $16.92 $16.92 DESCRIPTIONp`�k�ACCOUNTe*'QTY ` ;PAIDDATE aAMOUNT;PAID�° SMI - RESIDENTIAL 101-0000-20308 0 $1.16 $1.16 9/21/15 j. .rc ?, +,,y #, -PAID`BY i ` METHOD,y '$,sRECEIPT#$ 's4 CLTD BYE,. a�� zEs3CHECK# r= RON SAWYER CONSTRUCTION INC CHECK -MR226 27320• MFA Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.16 $1.16 TOTALS: Description: SATHER GLEN & ANN CLOSET ADDITION iCHRONOLOGY Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: ISSUED Applied: 8/19/2015 PJU Approved: 9/18/2015110 Parcel No: 658220029 Site Address: 77330 VISTA ROSA LA QUINTA,CA 92253 Subdivision: TR 25237 - •Block: Lot: 54 Issued: 9/21/2015 MFA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: , Valuation: $8,888.00 - Occupancy Type: P Construction Type: Expired: 3/19/2016 MFA No. Buildings: 0 No. Stories: -O ' I No. Unites: 0 FROM CONSULTANT Details: '110 SQ. FT. ADDITION TO CLOSET. PER 2013 CRC CODES r - -8/28/2015 - .. - �, . � Approv�ed�to� ssued�•,�� • R iCHRONOLOGY # 30," 3 'CHRONOLOGY TYPE .y;,. -ACTION DATE COMPLETION DATE. NOTES - .. - �, . � Approv�ed�to� ssued�•,�� • R Printed: Monday, September 21, 2015 12:38:11 PM 1of4 "`' iCHRONOLOGY 'CHRONOLOGY TYPE .y;,. -ACTION DATE COMPLETION DATE. NOTES NOTE JIM JOHNSON ,9/10/2015 9/18/2015 PENDING STRUC APPROVAL -PLAN CHECK COMMENTS _ FROM CONSULTANT MARY FASANO' 8/28/2015 -8/28/2015 RECEIVED. PLAN CHECK PICKED UP MARY FASANO 9/3/2015 9/3/2015 t PLAN CHECK -SUBMITTAL PLAN CK SUBMITTED BY ARCHITEC JMA / CONTACT RYAN PHILIP JUAREZ 8/18/2015 8/18/2015 — RECEIVED -ARIAS 760346-6155 TELEPHONE CALL JIM JOHNSON 9/2/2015 9/2/2015 CALLED RYAN TO INFORM HIM PLANS ARE READY FOR CORRECTIONS TELEPHONE CALL JIM JOHNSON 9/18/2015 9/18/2015 CALLED RYYAN TO INFORM HIM PLANS ARE READY TO ISSUE. NEED SCHOOL FEE LETTER. Printed: Monday, September 21, 2015 12:38:11 PM 1of4 "`' -CONDITION ,7 ��"`,DATE� A -f9_`DATE4- P�.;;` ATE43,�-� �7­d D -.4" "VAN" hl, PE 'STATUS k UIR SATISFIEWi� READY TO ISSUE 9/10/2015 PENDING CHECKLIST CONTACTS STATE r q�'� FAX,. EMAIL S PHONE- - APPLICANT JMA ARCHITECTURE, INC. P.O. BOX 778 PALM DESERT CA 92261 (760)200-0893 ARCHITECT JMA ARCHITECTURE, INC. P.O. BOX 778 PALM DESERT CA 92261 (760)200-0893 CONTRACTOR 'RON SAWYER CONSTRUCTION INC 78525 AVENUE 41 BERMUDA CA 92203 (760)200-0893 DUNES OWNER GLENN & ANN SATHER 77330 VISTA ROSA LA QUINTA CA 92253 (760)200-0893 .. FINANCIAL . . .... ... INFOWAfION' ;04%......... . . . . . . . . . . . . . ... DESCRIPTION, PAID :PAID. Yt. -,1;3 5:ztt�� �Mv 7 BY ADDITION, EA .101-000.0-42400 0 $62.36 $62-36, 9/21/15 MR226 27320 CHECK- RON SAWYER MFA ,ADDITIONAL 500 SF CONSTRUCTION INC ADDITION, EA RON SAWYER 101-0000-42660 0 $17.40 $17.40 9/21/15 MR226 CHECK MFA ADDITIONAL 500 SF PC CONSTRUCTION INC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 9/21/15 MR226 27320 CHECK RON SAWYER MFA CONSTRUCTION INC ADDITION, FIRST 100 SF RON SAWYER 101-0000-42600 0 '$171.14 $171.14 9/21/15 MR226 27320 MFA PC. - CONSTRUCTION INC Total Paid for ADDITION: $371.73 $371.73 HOURLY PLAN CHECK - RON SAWYER 101-0000-42600 2 $146.00 $140.00 0/21/15 MR226 27320 CHECK. MFA YES CONSTRUCTION INC HOURLY PLAN CHECK - RON SAWYER 101-0000-42660 1 $70.00 $70.00 9/21/15 MR226 27320 CHECK MFA YES CONSTRUCTION INC Total Paid for BLDG CITY STAFF - PER.HOUR: $210.00 $210.00 Printed:. Monday, September 21, 2015 12:38:11 PM 2 of 4 CRSYSTEMS' DESCRIPTION ACCOUNT .. 771 Q TY AMOUNT PAID PAID OATE., yRECEIPT ;# CHECK # METHOD , PAID BY CLTD 13Y . {` ' BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 9/21/15 MR226 27320 CHECK RON SAWYER MFA CONSTRUCTION INC Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03' 9/21/15 MR226 27320 CHECK RON SAWYER MFA 1,000SF CONSTRUCTION INC RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 9/21/15 MR226 27320 CHECK RON SAWYER MFA 1,000SF, PC CONSTRUCTION INC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 APPLIANCE 101-0000-42402 0 $12.09 $12.09 9/21/15 MR226 27320 CHECK RON SAWYER MFA REPAIR/ALTERATION CONSTRUCTION INC APPLIANCE 101-0000-42600 0 $4.83 $4.83 9/21/15 MR226 27320 CHECK RON SAWYER MFA REPAIR/ALTERATION PC CONSTRUCTION INC Total Paid for MECHANICAL:. $16.92 $16.92 SMI - RESIDENTIAL 101-0000-20308 0 $1.16 $1.16 9/21/15 MR226 27320 CHECK RON SAWYER. MFA CONSTRUCTION INC Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.16 $1.16 TOTALS: ,....- PARENT..PROIECTS: ,.,.,,.. ,.., ... ,,..,.., ..,,,.. ,.. Printed: Monday, September 21, 2015 12:38:11 PM. 3 of 4 ' SYSTEMS STRUCTURAL -,2 WK YOUNG 8/18/2015 9/1/2015 8/27/2015 REVISIONS REQUIRED DOC 9/2/2015 JIM JOHNSON ENGINEERING 77-330 VISTA 0. ' NON-STRUCTURAL - JIM JOHNSON 8/19/2015 9/2/2015 9/2/2015 REVISIONS REQUIRED SCHOOL FEES BRES2015- 2 WK DOC 9/2/2015 = - ' 2ND BLDG NS (1 .WK) JIM JOHNSON 9/9/2015 9/16/2015 9/10/2015. APPROVED 0313.pdf - IST REVIEW - 2ND BLDG STR (1 YOUNG 9/9/2015 9/16/2015 7; 9/17/2015 READY FOR APPROVAL DOC WK) ENGINEERING STRUCTURAL - 0 - BOND INFORMATION :�•-sem. >:,.� ,.. .,� s:;,. �»*�-,��:•� . ,•,.�.�, ..,r� , ::A.:w� �• � a-.�, ..�,.�._. �..___..>: . t.,--,.• Attachment:T a = CREATED g�> _ 'O.UVNER� ... :A°. DESCRIP:TION, •,4PATHNAME , SUBD'IR =ETRAKITENABLED .. s,. N.. _ DOC 9/2/2015 JIM JOHNSON 77-330 VISTA 77-330 VISTA 0. ROSA.docx ROSA.docx ' SCHOOL FEES BRES2015- SCHOOL FEES BRES2015- DOC 9/2/2015 = JIM JOHNSON ' 0 0313.pdf 0313.pdf - IST REVIEW - y BRES 2015-0313 K5 DOC 8/27/2015 KATHRYN SAMUELS STRUCTURAL - 0 - (ist).doc- COMMENTS _ 1ST REVIEW - NEW CITY - DOC 8/27/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES R 0 TRANSMITTAL 2015-0313 (lst)_l.pdf - 2ND REVIEW - NEW CITY DOC -9/17/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0313 (2nd).pdf Printed: Monday, September 21, 2015 12:38:51 PM 4 of 4 CIRWYSTEMS Bin #4 G Permit # /� /� City of La Q uin to Building 8z Safety Division W�► P.O. Box 1504 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking•Sheet Project Address: 77 I Owner's Name: '62 -n d- rl n (1n L i A. P. Number: (o S" 22i7 .0 2 Address: % - 3 3 0 Legal Description: City, ST; Zip: I-cA- QA o Contractr:INsh" Te ec 0/7. »>s>> Address: -756526- ( I Project Description: 1/0 } (f)0t l—...... City, ST, Zip: ct-hd Tele h ne• o . - Lt�n �-CM,,2, P 2.0- State Lie. # : 654 31aj1P City Lic. #; Ar ., Engr., Designer: Address: Zt7 City., ST, Zip: G �� �eSF'{^ l/► 9 ZZ 60 Tele h one: D P 6 �5 3 S y � 7 b 6 Con tructi T -3 s on e: Occupancy: O Y Y� P P State Lie. #�•Z 4 2 6 -Iter r Demo type (circle one): �ARepairai Name of Contact Person(i� G� T Sq. Ft.: Jl7 #Stories: Units: Telephone # of Contact Person: -7b0 3 6 6 /S5- Estimated Value of Project- '7,5:'_/0(20 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted \ Item Amount Structural Cafes. _ Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan god Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN HOUSE:- 3' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees y�$ �a c�a�rado� YOUNG o o ENGINEERINGW a . ' r• . Letter of Transmittal. - To: City of La Quints f Today's Date: ' - 9-17-15 78-495 Calle Tampico : City Due Date: 9-16-15 La Quinta, CA 92253 Project Address:.. 77330 Vista Rose Attn: Kay s ` Plan Check #: BRES 2015-0313 Submittal:. ❑ " 15t El 4m , ❑ 3rd ❑' "Other: We are forwarding: ®.' "By Messenger ❑ ' , By Mail (Fed Ex or UPS) ❑ Your Pickup •,# Includes: # Of Descriptions: , Includes: Of , Descriptions: Copies: r 3 "Copies: , ElStructural Plans ®' 1 Revised Structural Plans ® 1 Structural Calculations ® 1 Revised Struct. Calcs • Truss Calculations Floor., ❑ ❑ N Revised Truss and Roof ❑ Soils Report 411 ❑ Revised Soils Report Structural Comment List/, ❑ ` r Approved Structural Plans Responses - , ' ® 1 Redlined Structural Plans ❑ -, , Approved Structural Calcs ` ' ❑ Redlined Structural Calcs ❑ ... Approved Truss Calcs ❑ Redlined Truss Calcs _ ❑ - _ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural'content is approvable. If you have any questions,• please call.' J" Time =1 HR ..,.,` This Material Sent for:,e•, ❑ Your Files- {. y Per Your Request ❑ Your. Review ❑ "Approval • ❑ Checking ❑ 'At the request of: Other: ❑ y' BY: Kathryn Samuels. Palm Desert Office :.Z .(760)'772-5107 " Other . ❑ . r ♦ 4. i F �. BUILDING ENERGY ANALYSIS REPORT RECEIVED PROJECT: AUG. 1 8 2015 Sather Residence CITY OF LA QUINTA . 77-330Vista Rosa COMMUNITY DEVELOPMENT `La Quinta, CA 92253 Project Designer: JMA Architecture' and Engineering 73-995 EI Paseo Suite 203 W s Palm Desert, CA 92260 y (760) 346-6155,-�� CIS :f1T EPBUILDIN!C L)i Report Prepared by FOR U', -i"``TION l Jon Scott DATE q JS LS t� Scott Design and Title 24, Inc, - — `� 77-085 Michigan Drive Palm Desert, CA 92211 ,(760)`200-4780. L RECEIVED of SEP 0 9 2015 t Job Number: CITY OF €:,:A QUINTA COMMUNITY DEVELOPMENT Date: 8/7/2015• The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. Ene Pro 6.7 ;y E - nergySoft User Number: 6712. ID: .. I l CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD Project ame: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml C FIDRF-01' Page 1 of 9 GENERAL INFORMATION ®®� ENERGY USE SUMMARY 01 Project Name Sather Residence 04 00, 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 77-330 Vista Rosa Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 5490 1s A� Number of Zones 2 16 Slab Area (ft) 5490 17�(� Number of Stories 1 18 Addition Cond. Floor Area 110 ^91 Natural Gas Available Yes 20 Addition Slab Area (ft2) 110 �t 1 Glazing Percentage (%) 22.6% Amw COMPLIANCE RESULTS 01 Building Complies with Computer Performance �W 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shoswn`tbelow ♦Ao Registration Number: �4p® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-07 09:42:40 ®®� ENERGY USE SUMMARY 04 00, 06 07 08 Energy Use (kTDV/ft2-yr) Sta�nSarard Design Proposed Design Compliance Margin Percent Improvement Space Heating Iv 11.90 11.24 0.66 5.5% Space Cooling 247.30 243.63 3.67 1.5% IAQ Ventilation 0.00 0.00 0.00 0.0% Water HeatingA;� 4.58 4.50 0.08 1.7% Photovoltaic Offset A,' �Y' — 0.00 0.00 — Compliance Energy Total &®k 263.78 259.37 4.41 1.7% ♦Ao Registration Number: �4p® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-07 09:42:40 CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE�OD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. CRF -01 Page 2 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. " Building -level Verifications: Cooling System Verifications: — None — HVAC Distribution System Verifications: • -- None — Domestic Hot Water System Verifications:' - None — ENERGY DESIGN RATING o� This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use - a- Energy Design Rating' Margin Percent Improvement Total Energy (kTDVlf2-yr)` 299.96 ' �k29555 ' 4.41 1.5% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING -FEATURES INFORMATION 01 02,0`3 04 05 ' 06 07 Numiler of Dwelling Zone Floor Area Avg. Ceiling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Sather Residence 5490 F 1 3 2 1 1 ZONE INFORMATION 01 02 04 03 04 05 06 07 �i Zone Floor Area Avg. Ceiling Zone Name Zone Typef', HVAC System Name (ft) Height Water Heating System 1 Water Heating System 2 Main Conditiofieci CERTIE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE �OD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xmi CORF-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (W) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition 80d Wall ex Main R-13 Wall (W.13.2x6.16) 80 Front 2820 303.8 90 Existing No 170d Wall ex Main R-13 Wall (W.13.2x6.16) 170 Left 3210 347.2 90 Existing No 260d Wall ex Main R-13 Wall (W.13.2x6.16) 260 Back 2820 142.6 90 Existing No 350d Wall ex Main R-13 Wall (W.13.2x6.16) 350 Right 3210 _ 444.5 90 Existing No Roof ` Main Default 1978 to present.. 5380 Existing No 80d Wall .,'add R-21 Wall (W.21.2x6.16) 80 ,� Front 400 90 New N/A 170d Wall `, add R-21 Wall (W.21.2x6.16) 170 Left 600. 4.6 90 New N/A 260d Wall add ' ' r R-21 Wall (W.21.2x6.16) 2604 Back 400 90 New N/A Roof 2 add ' . R-38 Roof Attic 110 New N/A ATTIC 01 , 02 " , 03 ' �C04 05 _06 07 08 09 10 Radiant Statu Verified Existing 'Name Construction . 'Type •oQ Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition- Attic Main : Attic RoofMain VentilatedZ 3 0.1 0.85 No No Existi No �._ j ng Attic add Attic Roofadd Ventilated 3 0.1 0.85 No No New No eN� ♦ �d Registration Number: �e�Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-08-07 09:42:40 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xmi CF*RF-01 Page 4of9 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition 3x4.5 ex m 80d Wall ex (Front -80) - -- 1 13.5 0.39 0.18 Insect Screen (default) Existing No 6x7 ex 7 80d Wall ex (Front -80) - - 1 42.0 0.39 0.18 Insect Screen (default) Existing No 2.3x7 ex 18 80d Wall ex (Front -80) - -- 1 16.1 0.39 0.18 Insect Screen (default) Existing No 4x8 ex 23 80d Wall ex (Front -80) - - 1 32.0 0.39 0.18 Insect Screen (default) Existing No 5x8 ex r 80d Wall ex (Front -80) - -- 1 40.0 0.39 0.18 Insect Screen (default) Existing No 3.4x6.5 ex gg 80d Wall ex (Front -80) - - 1 22.1 0.39 0.18 Insect Screen (default) Existing No 5.5x8 ex 22 80d Wall ex (Front -80) - -- �1�� 44.0 0.39 0.18 Insect Screen (default) Existing No 3.4x6.5 ex hh 80d Wall ex (Front -80) - - e �1 22.1 0.39 0.18 Insect Screen (default) Existing No 5x8 ex s 80d Wall ex (Front -80) - -- 1 40.0 0.39 0.18 Insect Screen (default) Existing No 4x8 ex 32 80d Wall ex (Front -80) - - 1 32.0 0.39 0.18 Insect Screen (default) Existing No 2.4x4.5 ex n 170d Wall ex (Left -170) - 1 10.8 0.39 0.18 Insect Screen (default) Existing No 6x8 ex 27 170d Wall ex (Left -170) - 1 48.0 0.39 0.18 Insect Screen (default) Existing No 2.5x4 ex t 170d Wall ex (Left -170) - `- 1 10.0 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex w 170d Wall ex (Left -170) - -- 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex ww 170d Wall ex (Left -170) -- Aw 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex v 170d Wall ex (Left -170) �� -- 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex vv 170d Wall ex (Left -170) !!fir-- 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex u 170d Wall ex (Left -170) 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex uu 170d Wall ex (Left -170) j v - -- 1 2.3 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 1 170d Wall ex (Left -170)x, - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 1 2 170d Wall ex (Left -170) - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 1 3 170d Wall ex (Left -1 0 - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 12.8x4 ex h 170d Wall ex (Leftvy'-170) -- -- 1 51.2 0.39 0.18 Insect Screen (default) Existing No 2.8x4 ex c 170d Wall ex Sj of -170) - - 1 11.2 0.39 0.18 Insect Screen (default) Existing No 4.3x8 ex 11 170d Wali ez��(Left-170) - -- 1 34.2 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 30 260d WAW (Back -260) - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 6.8x5.8 ex ff 260d W�+"all ex (Back -260) - - 1 39.4 0.39 0.18 Insect Screen (default) Existing No 2.8x4 ex d 2t6CVNall ex (Back -260) -- -- 1 11.2 0.39 0.18 Insect Screen (default) Existing No 7x4 ex g �260d Wall ex (Back -260) - - 1 28.0 0.39 0.18 Insect Screen (default) Existing No Registration Number: A�i CA Building Energy Efficiency Staha ds - 2013 Residential Compliance Registration Datefrime: Report Version - CF111-07082015-744 HERS Provider: Report Generated at: 2015-08-07 09:42:40 CERTI�E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD CF*RF-01 Project M1Tame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015 Page 5 of 9 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xm1 2x2 ex f 260d Wall ex (Back -260) - - 1 4.0 0.39 0.18 Insect Screen (default) Existing No 2x2 ex 11 260d Wall ex (Back -260) - - 1 4.0 0.39 ' 0.18 Insect Screen (default) Existing No 3.7x8 ex 10 350d Wall ex (Right -350) - - 1 29.60.39 0.18 Insect Screen (default) Existing No 7x6 ex a 350d Wall ex (Right -350) - - 1 42.0 0.39 0.18 Insect Screen (default) Existing No 7x10 ex 2a 350d Wall ex (Right -350) - -- 1 70.0 0.39 0.18 Insect Screen (default) Existing No 7x10 ex2 350d Wall ex (Right -350) - - 1 70.0 0.39 0.18 Insect Screen (default) Existing No 7x10 ex 2a 2 350d Wall ex (Right -350) - -. 1 70.0 0.39 0.18 Insect Screen (default) Existing No 6.7x8 ex 3 350d Wall ex (Right -350) - - 1 53.6 0.39 0.18 Insect Screen (default) Existing No 6x8 ex s 350d Wall ex (Right -350) - 1 48.0 0.39 0.18 insect Screen (default) Existing. No 6x7 ex k 350d Wall ex (Right -350) - --" 1 J 42.0 0.39 0.18 Insect Screen (default) Existing No 2x4 ex j 350d Wall ex (Right -350) - - 1 8.0 0.39 0.18 Insect Screen (default) Existing No 2.5x4.5 ex I 350d Wall ex (Right -350) - --'� 11.3 0.39 0.18 Insect Screen (default) Existing No . 1.5x1.5 ex o 170d Wall (Left -170) - .1 2.3 0.39 0.18 Insect Screen (default) Existing , No 1.5x1.5 ex o 2 170d Wall (Left -170) - - A i 1 2.3 0.39 0.18 Insect Screen (default) Existing No ®v t o® to Registration Number: ®� % Registration Date/Time: CA Building Energy Efficiency Stan daar'ds - 2013 Residential Compliance Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-08-07 09:42:40 a - HERS Provider: Report Generated at: 2015-08-07 09:42:40 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xm1 CF*RF-01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 • Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Perimeter Carpeted Existing • Cavity/Frame: no insul. /2x4 Top Choi Zone �� Area (ft) (ft) 2x4 Top Chord of Roof Truss @ 24 Fraction Heated Roof Deck., Wood Siding/sheathing/decking Attic RoofMain Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing. Light Roof (Asphalt Shingle) No Existing No Covered Slab addAft 110 • Inside Finish: Gypsum Board None Ceilings (below No New No Cavity/Frame: R-9.1 /2x4 Default 1978 to present.. attic) Wood Framed Ceiling '2x4 @ 16 in. O.C. R11 0.083 Over Floor Joists: R-1.9 insul. > Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wail (W.13.2x6.16) Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof T ss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofadd Attic Roofs Wood Framed Ceiling in. O.C9 none 0.644 Roofing: Light Roof (Asphak Shingle) Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4_@�16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 o @� Exterior Finish: Wood R-21 Wall (W21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking VWA SLAB FLOORS WIV 01 02 �03 04 05 06 07 08 09 • Verified Perimeter Carpeted Existing Name Zone �� Area (ft) (ft) Edge lnsul. R -value Fraction Heated Status Condition Covered Slab ex Main 5380 286 None 0.8 No Existing No Covered Slab addAft 110 38 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION W.91 01 �f �` 02 03 04 Quality Insulation Installation (QII)®� Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required ®V Not Required Not Required — !Ai Registration Number: CA Building Energy Efficiency Stan`da ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-08-07 09:42:40 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE CWOD Project ame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml CF*RF-01 Page 7 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 1 07 08 Name Heater Element Type Tank Type Tank Volume (gal) ZE nergy Factor or r�►� Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) ' DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING -,HERS VERIFICATION ?®� 01 02 03 �) 04 05 06 07 Name Pipe Insulation - Parallel Piping, Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a te n/a n/a n/a ,, n/a SPACE CONDITIONING SYSTEMS o® 01 02, 03 04 05 06 07 08 09 Heating System . Cooling System ' w �� > Distribution Fan Floor Area Verified Existing Name System Type Name Ducted off® Name Ducted System System Served Status Condition HVAC1 Other Heating. and Heating Y"�' " Cooling Yes Air Distribution HVAC Fan '`490 Existing No Cooling System Component 1 Component 1 System 1 1 all HVAC - HEATING SYSTEMS 01 02 03 Name �A . Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE o e® o®� Registration Number: CA Building Energy Efficiency Stan daar'ds - 2013 Residential Compliance Registration Date/Time: Report Version - C17111-07082015-744 HERS Provider: Report Generated at: 2015-08-07 09:42:40 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD , Project ame: Sather Residence ation Date/Time: 09:41, Fri, Aug.07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml CFORF-01 Page 8 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed OS 06 Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 Yes No N/A — system Status Condition Verification HVAC - DISTRIBUTION SYSTEMS 01 02• 03 04 05 06 07 08 09 10 • OS 06 - Insulation Supply Duct Retu" rn Duct Verified Duct Design Name Verified Existing HERS Name Type Duct Leakage R -value Location — Bypass Duct Status Condition Verification �(LLocation Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No • N/A System 1 specified) $ � o® d HVAC DISTRIBUTION - HERS VERIFICATION Q 01 02 03 04 Name �� Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 01. 02 03 04 OS 06 - - Duct Leakage Duct Leakages Verified Duct Design Name Verification Target (0/,d) Verified Verified Duct Location Return Supply Air Distribution System 1 -hers -dist N/A .—� — — — IAQ (Indoor Air Quality) FANS 01 02 �03 04 05 . Name IAQ CFM o�{�a IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION , ®;to 01 02 03 04 Name �� Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 o® Registration Number: 44 ® Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 HERS Provider: k Report Generated at: 2015-08-07 09:42:40 ' CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD CFORF-01 Project ame: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Page 9 of 9 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xm1 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:, Documentation Author Signature: Jon Scott Company: Signature Date: Scott Design and Title 24, Inc, - 8/7/2015 Address: CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive - City/State ip al'm Desert; CA 92211 Phone:. (76,0) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT�- I certify the following under penalty of perjury, under the laws of the State of California og� 1. 1 am eligible under Division 3 of the Business and Professions,Code to accept responsibility for theme building design identified on this Certificate o� Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of,Compliance conform to the requirements of Title/24, Part 1 and Part 6 of the California Code of Regulations. /n 3. The building design features or.system design features identified -on this Certificate of Compliance are consistent with the information provided other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency�for approval with this building permit application: / l Responsible Designer Name: 41:� Responsible Designer Signature: JMA Architecture and Engineering. ,�Aft Company: V Date Signed: L JMA Architecture and Engineering Address: w �� License: 73-995 El Paseo Suite 203 City/State/Zip: Phone: - Palm Desert, CA 92260 (760) 346-6155 ®AV Registration Number: ® Registration Date/Time: HERS Provider: ' CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFlR-07082015-744 Report Generated at: 2015-08-07 09:42:40 • C` • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Sather Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date $/7/2015 Project Address 77-330 Vista Rosa La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,490 Addition 110 # of Units 1 INSULATION Construction Type Area Cavi(ft) Special Features Status Roof Wood Framed Attic R11 5,380 Existing Wall Wood Framed R 13 10,822 Existing Slab Unheated Slab -on -Grade - no insulation 5,380 Perim = 286' Existing Demising Wood Framed - no insulation 735 Existing Roof Wood Framed Attic R38 110 New Wall Wood Framed R 21 1,395 New Slab Unheated Slab -on -Grade - no insulation 110 Perim = 38' New FENESTRATION Total Area: 1,243 Glazin Percentage: 22.6T, New/Altered Average U -Factor: 0.00 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (E) 303.8 0.390 0.18 none none Bug Screen Existing Left (S) 351.8 0.390 0.18 none none Bug Screen Existing Rear (IM 142.6 0.390 0.18 none none Bug Screen Existing Right (N) 444.5 0.390 0.18 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 4 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Enerq yPro 6.7 by EnemySoft User Number: 6712 Run Code: 2015-08-07T09:43:19 /D: Pae 12 of 26 L 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the corn liance approach used. Exceptions may apply, Review the respective code section or more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §I 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-11l(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § I50.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §I50.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 § I50.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device. §I50.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150 .0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § I50.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.OQ)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § I50.0Q)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § ] 50.0(n)l : space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § ] 50.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § ] 50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)l0: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §I50.0(m)]2: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow>_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 4 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)]A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §I50.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)1 C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § I50.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in ' 150.0(k)2. § ] 50.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § ] 50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § ] 50.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 2013 Low -Rise Residential Mandatory Measures Summary 7� a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, § 130.2, §130.4, §140.7 and § 141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2 § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, §130.2, §130.4, §140.7 and § 141.0. § I50.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 § 130.0, § 130.1 § 130.4, § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I 50.0(k) I 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §I50.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §110.10 b through §110.10 e . §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §I 10.10(d). The solar zone shall have'a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 7� 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ather Residence Date 8/7/2015 System Name HVAC Floor Area 5,490 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 4 COIL CFM Total Room Loads 7,726 Return Vented Lighting Return Air Ducts Return Fan Ventilation 824 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 108,243 7,841 3,171 118,792 Total Output Btuh 356,000 0 Output Btuh/s ft 64.8 9,178 8,440 Cooling System 0 0 Output perSystem 57,800 35,863 14,926 824 39,445 Total Output Btuh 231,200 0 9,178 1 162,464 22,768 0 Total Output Tons 19.3 8,440 Total Output Btuh/s ft 42.1 Total Output s ft/Ton 284.9 175,116 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 8,000 Existing HVAC 166,308 32,452 356,000 Airflow cfmis ft 1.46 Airflow cfm/Ton 415.2 Outside Air % 10.3% Total Adjusted System Output 1 166,308 32,452 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM 356,000 Outside Air cfmis ft 0.15 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 824 cfm 71 OF 66 OF 108 OF _ 108 OF mom Heating Coil Supply Fan 107 OF 8,000 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/63°F 75/63°F 56/55°F Outside Air 824 cfm Supply Fan Cooling Coil 57 / 55 OF 8,000 cfm 58.1 % ROOM 71/61°F70/60°F U�E3 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-68-07T09:43:19 /D: Page 17 of 26 • ROOM HEATING PEAK LOADS Project Name78/7/2015 Sather Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Floor Area 5,380.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 5,380.0 X 0.0790 10,821.9 X 0.1020 1,238.1 X 0.3900 perim = 286.0 X 0.7300 625.0 X 0.3560 X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 5,380 X 9.00 X 0.266 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F 46 = 46 = 46 c 46 = 0 = = = = = = = = = = = = = = = = = Page Total /60] X 46 AT Btu/hr Default 1978 to present... 19,551 R-13 Wall (W. 13.2x6.16) 50,776 ex non metal Window. 39.18 22,212 Slab -On -Grade 9,604 'R-0 Interior Wall 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction 102,143 = 10,515 TOTAL HOURLY HEAT LOSS FOR ROOM 112,658 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-07T09:43:19 /D: Page 19 of 26 • C • ROOM HEATING PEAK LOADS Project Name Sather Residence Date 81712015. ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Residence Floor Area 110.0 ftz Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 AT OF X 46 X 46 X 46 X 46 X 0 X X X X X X X X X X X X X X X X X X X X X X X X X X Page Total /60] X AT Btu/hr = 132 = 4,429 = 83 = 1,276 0 0 = = = = = = = = = = = = = - = = = 5,919 46 = 215 R-38 Roof Attic 110.0 R-21 Wall (W.21.2x6.16) 1,395.4 X 0.0690 ex non metal Window.39.18 4.6 X 0.3900 Slab -On -Grade pen .m = 38.0 X 0.7300 "R-0 Interior Wall 110.0 X X 0.3560 X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.00 X 0.266 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 110 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 6,134 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 ID: Page 20 of 26 1� RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sather Residence 8/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Outdoor Dry Bulb Temperature 112 OF Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF ODaaue Surfaces Default 1978 to present... R-13 Wall (W..13.2x6.16) R-13 Wall (W. 13.24.16) R-13 Wall (W. 13.24.16) R-13 Wall (W.13.2x6.16) -R-0 Interior Wall Orientation (►M (E) (S) (tM (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 5,380.0 0.0790 56.0 2,516.2 0.1020 32.1 Z862.8 0.1020 27.1 2,677.4 0.1020 32.6 2,765.5 0.1020 29.0 625.0 0.3560 0.0 0.0 14.5 40.0 24.1 0.0 14.5 22.1 24.1 0.0 14.5 44.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 3x4.5 ex m 6x7 ex 7 2.3x7 ex 18 4x8 ex 23 5x8 ex r 3.46.5 ex gg 5.54 ex 22 3.46.5 ex hh 5x8 ex s Orientation (E) (E) (E) (E) (E) (E) (E) (E) (E) Shaded Unshaded Area X X X X -X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 14.5 13.5 24.1 0.0 14.5 42.0 24.1 0.0 14.5 16.1 24.1 0.0 14.5 32.0 24.1 0.0 14.5 40.0 24.1 0.0 14.5 22.1 24.1 0.0 14.5 44.0 24.1 0.0 14.5 22.1 24.1 0.01 14.5 40.0 24.1 Page Total Btu/hr 23,801 8,241 7,917 8,891 8,180 57, Btu/hr 325 1,011 388 770 963 532 1,059 532 6, Internal Gain Btu/hr- Occupants 16.1 Occupants X 245 Btuh/occ. = 3,954 Equipment 5,380 Floor Area . X 0.50 w/sgft = 9,181 Infiltration: 1.064 X 0.94 X 221.90 X 42 = 9,275 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104.656 Latent Gain Btu/hr Occupants Occupants X 155 Btuh/occ. = 2,502 Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 = 5,183 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR I EnergyPro 6.7 by EnemySoR User Number. 6712 Run Code: 2015-08-07709:43:19 ID: Paoe 21 of 26 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date ' Sather Residence 8/7/2015 ROOM INFORMATION DESIGN CONDITIONS' Room Name Existing Main Outdoor Dry Bulb Temperature 112 OF Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temuerature 70 OF Outdoor Dailv Ranae: 34 OF 17, Surfaces Orientation Area U -Factor CLTD' Page Total Items shown with an asterisk (') denote conduction through an interior surface to another. room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 4x8 ex 32 2.4x4.5 ex n 6x8 ex 27 2.5x4 ex t 1.5x1.5 ex w 1.5x1.5 ex ww 1.5x1.5 ex v 1.5x1.5 ex w 1.5x1.5 ex u Oripntatinn (E) (S) (S) (S) (S) (S) (S) (S) (S) Shaded Area X X X X X X X X X Unshaded Area + 32.0 X X X X X X X X. X 0.0 = = = = = = = _ - 24.1 c = 0.0 + + + + + 10.8 15.4 r 0.0 48.0 X X X X X X 15.4 = = = = = = 0.0 10.0 15.4 0.0 2.3 15.4 0.0 2.3 15.4 0.0 + 2.3 + 2.3 +1' 2.3 15.4 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another. room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 4x8 ex 32 2.4x4.5 ex n 6x8 ex 27 2.5x4 ex t 1.5x1.5 ex w 1.5x1.5 ex ww 1.5x1.5 ex v 1.5x1.5 ex w 1.5x1.5 ex u Oripntatinn (E) (S) (S) (S) (S) (S) (S) (S) (S) Shaded Area GLF X 14.5 X 14.5 X 14.5 X 14.5 X 14.5 X 14.5 X 14.5 X 14.5 X1 14.5 Unshaded Area + 32.0 GLF 0.0 X X 24.1 c = 0.0 + + + + + 10.8 15.4 r 0.0 48.0 X X X X X X 15.4 = = = = = = 0.0 10.0 15.4 0.0 2.3 15.4 0.0 2.3 15.4 0.0 + 2.3 + 2.3 +1' 2.3 15.4 0.0 15.4 0.0 X1 15.4 - Page Total Btu/hr Btu/hr 770 741 154 35 Internal Gain Btu/hr Occupants 16.1 Occupants X 245 Btuh/occ. = 3,954 Equipment - 5,380 Floor Area X 0.50 w/sgft = 9,181 Infiltration: 1.064 X 0.94 X. 221.90 X 42 9,275 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656 Latent Gain Btu/hr Occupants 1fi1 Occupants X 155 Btuh/occ. = 2,502 Infiltration: 4.771 X 0.94 X . 221.90 X 0.00523 = 5,183 Air Sensible CFM . ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2015-08-07T09:43:19 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sather Residence 8/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Outdoor Dry Bulb Temperature 112 OF Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF ue Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = 0 = = = Btu/hr 0.0 14.5 2.3 15.4 35 0.0 14.5 56.0 15.4 864 0.0 14.5 56.0 15.4 864 0.0 14.5 56.0 15.4 864 0.0 14.5 51.2 15.4 790 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration 1.5x1.5 ex uu 7x8 ex 1 7x8 ex 1 7x8 ex 1 12.8x4 ex h 2.8x4 ex c 4.3x8 ex 11 7x8 ex 30 6.8x5.8 ex ff Orientation (S) (S) (S) (S) (S) (S) (S) (K9 (tM Btu/hr Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X1 GLF = = = = = 0 = = = Btu/hr 0.0 14.5 2.3 15.4 35 0.0 14.5 56.0 15.4 864 0.0 14.5 56.0 15.4 864 0.0 14.5 56.0 15.4 864 0.0 14.5 51.2 15.4 790 0.0 14.5 11.2 15.4 173 0.0 14.5 34.2 15.4 528 0.0 14.5 56.0 24.8 1,387 0.0 14.5 1 39.4 24.8 976 Page Total 6,482 Internal Gain Btu/hr Occupants 16.1 Occupants X 245 Btuh/occ. 3,954 Equipment 5,380 Floor Area X 1 0.50 w/sgft = 9,181 Infiltration: 1.064 X 0.94 X 221.90 X 42 = 9,275 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104.6561 Latent Gain Btu/hr Occupants 16.1 Occupants X 155 Btuh/occ. = 2,502 Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 = 5,183 Air Sensible CFM ELA AW AL HOURLY LATENT HEAT GAIN FOR ROOM RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sather Residence 8/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Outdoor Dry Bulb Temperature. 112 OF Floor Area 5,380.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = X X X X X X X X X 24.8 = = = = = = = = = 0.0 14.5 24.8 0.0 14.5 24.8 0.0 14.5 24.8 0.0 14.5 20.3 0.0 .14.5 20.3 0.0 14.5 20.3 Page Total L Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF' Area GLF 2.8x4 ex d 7x4 ex g 2x2 ex f 2x2 ex J 3.7x8 ex 10 7x6 ex e 7x10 ex 2a 7x10 ex2 7x10 ex 2a Page Total r Internal Gain Occupants 16.1 _Occupants X 245 Btuh/occ. Equipment 5,380 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.94 X 221.90 X 42 = Air Sensible CFM ELA AT Btu/hr Btu/hr 277 694 99 99 600 851 1,419 1,419 1,419 6,87 Btu/hr 1 9,1811 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656 r Latent Gain Occupants 161 Occupants X 155 Btuh/occ. Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Btu/hr 1 5,1831 LEnemyPro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 ID: Page 24 of 26 0.0 X X X X X X X X X 114.5 +g + + +, + +" + + + X X X X X X X X X 24.8 = = = = = = = = = 0.0 14.5 24.8 0.0 14.5 24.8 0.0 14.5 24.8 0.0 14.5 20.3 0.0 .14.5 20.3 0.0 14.5 20.3 0.0 14.5 20.3 0.0 14.5 20.3 Page Total r Internal Gain Occupants 16.1 _Occupants X 245 Btuh/occ. Equipment 5,380 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.94 X 221.90 X 42 = Air Sensible CFM ELA AT Btu/hr Btu/hr 277 694 99 99 600 851 1,419 1,419 1,419 6,87 Btu/hr 1 9,1811 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656 r Latent Gain Occupants 161 Occupants X 155 Btuh/occ. Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Btu/hr 1 5,1831 LEnemyPro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 ID: Page 24 of 26 C C � J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sather Residence 8/7/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Main Outdoor Dry Bulb Temperature 112 OF Floor Area 5,380.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 6.7x8 ex 3 (N) 0.0 X 14.5 + 53.6 X 20.3 = 1,086 6x8 ex s (N) 0.0 X 14.5 + 48.0 X 20.3 = 973 6x7 ex k (N) 0.0 X 14.5 + 42.0 X 20.3 = 851 2x4 ex j (N) 0.0 X 14.5 + 8.0 X 20.3 = 162 2.5x4.5 ex I (N) 0.0 X 14.5 + 11.3 X 20.3 = 229 X + X X + X = X + X = X 1 +1 X = Page Total 3,302 Internal Gain Btu/hr Occupants 16.1 Occupants X 245 Btuh/occ. = 3,954 Equipment 5,380 Floor Area X 0.50 w/sgft = 9,181 Infiltration: 1.064 X 0.94 X 221.90. X 42 = 9,275 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 104,656 Latent Gain Btu/hr Occupants Occupants X 155 Btuh/occ. = 2,502 Infiltration: 4,771 X 0.94 X 221.90 X 0.00523 =. 5,183 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,502 EnergyPro 6.7 by EneMySoft User Number: 6712 RunCode: 2015-08-07T09:43:19 /D: Page 25 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name781712015 ate Sather Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 110.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic W 110.0 X 0.0260 X 56.0 = 160 R-21 Wall (W.21.2x6.16) (E) 400.0 X 0.0690 X 32.1 = 886 R-21 Wall (W.21.2x6.16) (S) 595.4 X 0.0690 X 27.1 = 1,114 R-21 Wall (W.21.2x6.16) (tA✓) 400.0 X 0.0690 X 32.6 = 899 'R-0 Interior Wall 110.0 X 0.3560 X 0.0 = 0 X X - X X = X X = X X I= Page Total 3,059 Items shown with an asterisk (') denote conduction through an interior surface to another room. + 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1.5x1.5 ex o (S) 0.0 X 14.5 + 2.3 X 15.4 = 35 1.5x 1.5 ex o (S) 0.0 X 14.5 + 2.3 X 15.4 = 35 X + X = i X + X = X + X = X + X = X + X = X + X = X + I XI = - Page Total 71 Internal Gain Btu/hr Occupants 0.3 Occupants X 245 Btuh/occ. = 81 Equipment 110 Floor Area X 0.50 w/sgft = 188 Infiltration: 1.064 X 0.94 X 4.54 X 42 = 190 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,588 Latent Gain Btu/hr Occupants 0 3 Occupants X 155 Btuh/occ. = 51 Infiltration: 4,771 X 0.94 X 4.54 X 0.00523 = 106 Air Sensible CFM ELA AW i TOTAL HOURLY LATENT HEAT GAIN FOR ROOM. 51 Ene Pro 6.7 by EnemySoft User Number.- 6712 RunCode: 2015-08-07709:43:19 ID: Page 26 of 26 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IWOD Project Name: Sather Residence IW culation DatelTime: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml C*RF-01 Page 1 of 9 GENERAL INFORMATION 01 Building Complies witFiComputer.PerformA-, ce 44m,Q 01 Project Name Sather Residence 03 This building incorporates one or�A Spec alF eatur�es shhow;—n l elow 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 77-330 Vista Rosa Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 5490 15 Number of Zones 2 16 Slab Area (ft2) 5490 17 Number of Stories 1 18 Addition Cond. Floor Area 110 19 Natural Gas Available Yes 20 Addition Slab Are0(ie) 110 21 Glazing Percentage (%) 22.6% COMPLIANCE RESULTS ',%�' 01 Building Complies witFiComputer.PerformA-, ce 44m,Q 02 This building incorporates' features that require fiel8 est ng and/or verifficat by certiI' dl HERS ater u dei the supervision of a CEC-approved HERS provider. em... � 03 This building incorporates one or�A Spec alF eatur�es shhow;—n l elow 06 07 Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-08-07 09:42:47 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 11.90 11.24 0.66 5.5% Space Cooling 247.30 243.63 3.67 1.5% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 4.58 4.50 0.08 1.7% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 263.78 259.37 4.41 1.7% Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-08-07 09:42:47 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD CRF-01Project Name: Sather Residence ation Date/Time: 09:41, Fri, Aug 07, 2015 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: Cooling System Verifications: — None — HVAC Distribution System Verifications: — None — Domestic Hot Water System Verifications: —None -- k ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. ; CERTI E OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE 4kOD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml CF*RF-01. Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft). Tilt (deg) ' Status Verified Existing Condition 80d Wall ex _ Main R-13 Wall (W.13.2x6.16) 80 Front 2820 303.8 90 Existing No 170d Wall ex . Main R-13 Wall (W.13.2x6.16) 170 Left 3210 347.2 90 Existing No 260d Wall ex Main R-13 Wall (W.13.2x6.16) 260 Back 2820 142.6 90 Existing No 350d Wall ex Main R-13 Wall (W.13.2x6.16) 350 Right 3210 444.5 90 Existing No Roof Main Default 1978 to present.. 5380 Existing No 80d Wall add R-21 Wall (W.21.2x6.16) 80 Front 400 90 - New N/A 170d Wall add i R-21 Wall (W.21.2x6.16) 170 Left 600 '4.6 90 New N/A 260d Wall add' 'E R-21 Wall (W.21.2x6.16) 260 Back 400 90 New N/A Roof 2 add.-? y. R-38 Roof Attic 110 New N/A #1 4 3 R ATTIC •�. U -.--j 01 .. y 02. - 03 04 ` 3 ` 06 07 OS 09 10 Name Consttion Type �y Ro f Rise Roof Refle ctance ' RoofjE mittan Radiant Barrier Cool Roof Statu s Verified Existing Condition Attic Main Attic RoofMaini Ve entilated a g 3 > K. 0.16' 0; 85 No No Existi ng No Attic add Attic Roofadd Ventilated 3 0.1 0.85 No No New No Registration Number: 215-Ao219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 CERTI'VE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Ca Project 'VE Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml C*RF-01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition 3x4.5 ex m 80d Wall ex (Front -80) - - 1 13.5 0.39 0.18 Insect Screen (default) Existing No 6x7 ex 7 80d Wall ex (Front -80) - - 1 42.0 0.39 0.18 Insect Screen (default) Existing No 2.3x7 ex 18 80d Wall ex (Front -80) - -- 1 16.1 0.39 0.18 Insect Screen (default) Existing No 48 ex 23 80d Wall ex (Front -80) - - 1 32.0 0.39 0.18 Insect Screen (default) Existing No 5x8 ex r 80d Wall ex (Front -80) - - 1 40.0 0.39 0.18 Insect Screen (default) Existing No 3.4x6.5 ex gg 80d Wall ex (Front -80) - -- 1 22.1 0.39 0.18 Insect Screen (default) Existing No 5.5x8 ex 22 80d Wall ex (Front -80) - - 1 44.0 0.39 0.18 Insect Screen (default) Existing No 3.4x6.5 ex hh 80d Wall ex (Front -80) - - 1 22.1 0.39 0.18 Insect Screen (default) Existing No 5x8 ex s 80d Wall ex (Front -80) - - 1 40.0 0.39 0.18 Insect Screen (default) Existing No 48 ex 32 80d Wall ex (Front -80) - - 1 32.0 0.39 0.18 Insect Screen (default) Existing No 2.44.5 ex n 170d Wall ex (Left -170), - - 1 10.8 0.39 0.18 Insect Screen (default) Existing No 6x8 ex 27 170d Wall ex (Left -170),#'' --•� % A F y �{3¢ 1 '��(yr4-8.0 �!' ff 0.39 1 i ti 0_ 0.18 9 i.418 Insect Screen (default) Existing No 2.5x4 ex t 170d Wall (Left -170k F 1e kV . -- '1 1 1Or0� 0.39 y Ft0 18 Insect Screen (default) Existing No 1.5x1.5 ex w '. a^ t ' 'ta�+•ex b.i "s snw" 4.rn.xd11w/ 170d Wall ex (Left -170) _-_ _ - _ 1 _ 'F r 2.3 X y i 0.39 ' 0.18 Insect Screen (default) Existing No 1.5x1.5 ex ww "'170d Wall ex (Left,170) -r C i `M 1'QJ I:Z3 0�39 � 01'8 Insect Screen (default) Existing No 1.5x1.5 ex v 170d Wall ex (Left -170) - - 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex vv 170d Wall ex (Left -170) -- - 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex u 170d Wall ex (Left -170) - - 1 2.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex uu 170d Wall ex (Left -170) - - 1 2.3 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 1 170d Wall ex (Left -170) -- -- 1 56.0 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 1 2 170d Wall ex (Left -170) - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 1 3 170d Wall ex (Left -170) - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 12.8x4 ex h 170d Wall ex (Left -170) - - 1 51.2 0.39 0.18 Insect Screen (default) Existing No 2.8x4 ex c 170d Wall ex (Left -170) - - 1 11.2 0.39 0.18 Insect Screen (default) Existing No 4.3x8 ex 11 170d Wall ex (Left -170) - - 1 34.2 0.39 0.18 Insect Screen (default) Existing No 7x8 ex 30 260d Wall ex (Back -260) - - 1 56.0 0.39 0.18 Insect Screen (default) Existing No 6.8x5.8 ex ff 260d Wall ex (Back -260) - - 1 39.4 0.39 0.18 Insect Screen (default) Existing No 2.8x4 ex d 260d Wall ex (Back -260) - - 1 11.2 0.39 0.18 Insect Screen (default) Existing No 7x4 ex g 260d Wall ex (Back -260) - _- 1 28.0 0.39 0.18 - insect Screen (default) - Existing -- - - -No -- - Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml CF.RF-01 Page 5 of 9 2x2 ex f 260d Wall ex (Back -260) - - 1 4.0 0.39 0.18 Insect Screen (default) Existing No 2x2 ex jj 260d Wall ex (Back -260) - - 1 4.0 0.39 0.18 Insect Screen (default) Existing No 3.7x8 ex 10 '350d Wall ex (Right -350) - - 1 29.6 0.39 0.18 Insect Screen (default) Existing No' 7x6 ex a 350d Wall ex (Right -350) - - 1 42.0 0.39 0.18 Insect Screen (default) Existing No 7x10 ex 2a 350d Wall ex (Right -350) - - 1 70.0 0.39 0.18 Insect Screen (default) Existing No 7x10 ex2 350d Wall ex (Right -350) - - 1 70.0 0.39 0.18 Insect Screen (default) Existing No 7x10 ex 2a 2 350d Wall ex (Right -350) - - 1 70.0 0.39 0.18 Insect Screen (default) Existing No 6.7x8 ex 3 350d Wall ex (Right -350) - - 1 53.6 0.39 0.18 Insect Screen (default) Existing No 6x8 ex s - 350d Wall ex (Right -350) - - 1 48.0 0.39 0.18 Insect Screen (default) Existing No 6x7 ex k Mcl Wall ex (Right -350) - -- 1_ 42.0 0.39 0.18 , Insect Screen (default) Existing No 2x4 ex j 350d Wall ex (Right -350) - - 1 8.0 .0.39 0.18 - Insect Screen (default) Existing No 2.5x4.5 ex I 350d Wall.ex (Right -350) - - 1 11.3 0.39 0.18 Insect Screen (default) Existing No 1.5x1.5 ex o 170d -Wall (Left -170) - - 1 2.3 0.39 0.18 Insect Screen (default) Existing No - 1.5x1.5 ex o 2 17l)djWall,(Left-170) - „17 - 1 2.3 0.39 0.18 Insect Screen (default) Existing No Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 R CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE !-IOD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml C*RF-01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 286 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd add 110 38 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck. Wood Siding/sheathing/decking Attic RoofMain Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default 1978 to present.. attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 • Exterior Finish: Wood R-13 Wall (W.13.2x6.16) - Exterior Walls = Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking 1114 Cavity / Frame: no insul. / 2x4 Top Chrd - 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofadd Attic Roofs:' - '„ ti Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) --.-•- - Inside Finish: Gypsum Board Ceilings (below ,-^ Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) , Wood Framed;Ceiling .2x4f@11.6 inw!O Cox R 381 0.025 Over Floor Joists: R-28.9 insul. f , Dam Inside Finish: Gypsum Board Cavity /Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Fram�!,Wall <2x6 @ 16�;in. Qom. !R 21-1 1 Ot066 Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (f:2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab ex Main 5380 286 None 0.8 No Existing No Covered Slab add 110 38 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 CERTI#E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Sather Residence Ca culation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml CF.*RF-01 Page 7 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 s WATER HEATING - HERS VERIFICATION r � 01 t' it 02 03 04 05 06 07 It Name T^ 'A�-<....- Pipe Insulation, - "" ' ~ Parallel Piping Compact Distribution Point -of Use Recirculation withRecirculation Manual Control with Sensor Control DHW Sys 1 n/a—,- n7a°%a w n/a n/a n/a SPACE CONDITIONING SYSTEMS 0-wo,a 1 01 02 ,(<` '�*_A03 H E RS 044 i V051, ) E06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes CoolingAir Yes Distribution HVAC fan 5490 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 - CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Sather Residence Calculation Date/Time: 09:41, Fri, Aug 07, 2015 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml CFORF-01- Page 8 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05, 06 07 07 08 Efficiency 10 Multi -speed OAV". AVtw A Verified'Dutaocition. ct Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 I SplitAirCond - Split air conditioning 10 12 I Yes No N/A I I system Status Condition I I I I HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage Target - N -0 -ft OAV". AVtw A Verified'Dutaocition. ct Verified Duct Design Return Supply Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage* R -value- Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None ExistingNo N/A System 1 1 �.. specified) F . HVAC DISTRIBUTION - HERS VERIFICATION t1tK.5 FKUVIULK 01 01 03 04 .05 03 04 05 06 Name Duct Leakage---, - ,Verification Duct Leakage Target - N -0 -ft OAV". AVtw A Verified'Dutaocition. ct Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Aft- IAQ (indoor Air Quality) FANS Y' t1tK.5 FKUVIULK 01 02 03 04 .05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam 1AQVentRpt 0 Default 0 Not Required .COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 Registration Number: 215-AO219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-07 09:42:47 CERTI E OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD CFJRF,01` Project IJame:.Sather Residence Calculation DatefTime: 09:41, Fri, Aug 07, 2015 Page 9 of 9 Calculation Description: Title 24 Analysis Input File Name: Sather-JMA-15.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: %rxrri.$'c6'i- Tim Scott Company: Signature Date: .Scott Design and Title 24, Inc. 2015-08-07 09:52:23 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive, City/State/Zip: Phone: Palm Desert, CA 92214 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penalty of pedury, under the laws of the State of California 1. I am eligible under Division 3 of the Business ;and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and perfoiniance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or systemdesign features ide itified_on-this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans aril specifications submitted "fie enforcement agencyr approval with this.,building permit application. Responsible Designer Name: ' F t (Responsible Designer Sig ature`. . Tim ScottLEIB' Company: Date Signed: y, Scott Design and Title 24, Inc. 2015-08-07 09: 2`23 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 r Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0219233A-000000000-0000 Registration Date/Time: 2015-08-07 09:52:23 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-07 09:42:47