9711-046 (SFD)U).
F_. ,
CV'W
Z) C,)
C) CCS
LLJ
o Z
CC) 0.
C>
CD -
LU
a.
U)
Z
LICENSED CONTRACTOR DECLARATION.
I k, ereby affirm under penalty of,perjury that I am licensed under provisions* of
,,Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.,
License # Lic. Class Exp. Date
6 _7
740,4
,/Date Contractor §ignature of C 0
4.
OWNER -BUILDER DECLARATION'
I hereby affirm under per;alty of perjury that I am exempt from the Contractor'§
License Law for the following reason:
as owner of the property, or my employees,with: wages as their. sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
1, as owner of, the" property, am exclusively�Contracting'with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
O I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm" Under penilty, of perjury one of the following declarations:
I have and will maintain -a certificate of consent to self-insbre for workers'
compensation,'as provided',for . by Section,3700,of the Labor'.&Ode, for the
performance of, the work for WA6h-this permit is issued.
I have and will maintain workers' compensati6n in'surance,,as required by
Sehon 3700 of the Labor'Code,,for the performance of the.work.for which.this
permit is issued. My workers' compensation insurance carrier '& policy no. are:
Cartier Policy No.
(This section need not be. completed if the permit valuation is for $100.00 or less).,
-I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to, the
Workers' compensation laws of California, and agree that, if I should become
subject to the Workers' compensation provisions of Section* 3700 of the Labor
Gode, I shall forthwith comply with those provisions.
Vbate*:..ApplicantAOX I I
-1 0 . T Compensation 1 k_�
Warning: Failure.to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and'civil fines up to $100,000,' in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject 'to the 'conditions and restrictions set forth on hid
application.
1. Each person upon whose behalf this application is made & each *person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes'null and void if
work is not commenced within 180 days from ' date of issuance of such.
permit, or cessation of work for 180 days will subject permit to cancellation.
(.certify that I have read this application and state that the above information is.
Correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize' representatives of this City, to enter upon
the above-mentioned property for inspection purposes.
innature (Owner/A-ent)a
I :Date
PERMIT# CONTROL#
BUILDING PERMIT
DATE YALUATION.-,LOT' TRACT •,
►.4 8
4 .47, 79
A 1
-1 6 'A
JOB SITE K_�
APN
'I'A RON
r9 yey
OWNER
CONTRACTOR'/ DESIGNER ENGINEER
XS C
J.230'11
r --295 RJWC14.0 LA Q�JINTA OR..
MMON7110NA14 CA TSWG"�
LA Q011111U. C_A_ 92153
76 ML4 .29016
M771-4941
USE OF PERMIT
cu.,, _110M C< 750.00 SF.
GARAGO4ARPOWI33100 sr
SEN TINLA T CO 1"' fjf"JON�"R UXTKIN
'sal
c,4.,)14,STRUr_, r
IJUIWC. 0. 101 -01W -418 -WO'
31,^47A Q
, S121.9v43.
Z
P L U1VffA W G F W: -
.00
1 .1 RESID t0l-OW241� M0 S� 9 60
. . .:: . , , . .
Cn
.. 0
... 1;
CRAI�IN* ru!A 01 3-000..
PIT
AftJ f . NPUGLLC'ANLACES S740.02
M LL
ff— C. DOP r') S Kv 41't
U_
%'1Z
-LESS >V
W NOW
Sg.r 'J,,j'�k4j
RECEIPT
DATE{
BY "
DATE FINALED
INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
, _
Underground Ducts
Forms & Footings
1ACK
Ducts
Slab GradeH
Return Air
Steel
Combustion Air
Roof Deck
6 _
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation 3
s/
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
'
Final
�
POOLS - SPAS
BLOCKWALL
APPROVALS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground PIN. Test
Final
Gas Piping
PLUMBING APPROVAL
Gas Test
Electric Final
Waste Lines
9y
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
/
Pool Cover
Sewer Connection
7
Encapsulation
Gas Piping
Gas Test
Appliances
_
Final
COMMENTS:
Ad
a
,P,ky g//l/%,
%�7/, '
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole 3/9 9-
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G. F.I.
Smoke Detectors
Temp. Use of Power
l
Final
Utility Notice (Perm) �f/�
a2 �I -of(,
4.4 "
P.O. BOX 1504 APPLICATION ONLY
'duilding — 78-495 CALLE TAMPICO
Address V ¢
LA QUINTA, CALIFORNIA 92253
Own era
(_F,4^ 1 SNTN r2_ ��� I� BUILDING: TYPE'CONST. OCC. GRP.
Mailing
Address,/0 SpA t -t S � � S-raV(�rf �v !A1 t~ , tl A.P. Number zo -- 07 1. 1 U Z-
. e
r
CityZip _ Tel. _r .A C-� Z5 t 3"1
OV1,UV �✓ 7Z f7&0)'77/–t SSC/ Legal Description
Contractor Project Description -5/4ZfVG4F.
5D 4f t' S Co V
Address
/0 !e;o7/4
Ity,r} Zip Teyglc
State Lic. City
& Classif. 7 p �Lic. # Z 90
Arch., Engr., , /
Designer !t/tic.CrvEr// 4�►f (a4'
Address Tel.
� s -f to CL�� D�I,,�, 3&o v zso
C'ty ! ,, -- // ZiF772
State
�✓1Clt64 �l/� /C'J Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby a firm that I ar�lice sddunder provtsion' s oflghapter 9 (commencing with Section
700 c)y%1visio of llte 7(iness and Professions ssions Cod) and my license is n;Q1 ffo� ar)O
effe 1. X / 1
SIGNATURE I I l DATE
OWNER -BUILDER DECLARATION
Ihereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,9usiness and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to 'its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for
thealleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars (8500).
1] I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does Such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion,. the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I l I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner or property who builds or 'improves (hereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
17 I am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worke 's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Pol'c No. Company
Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is to tin un red dollars (8100) vatuation
or less.)
I certify that in the performance -o the wor for which this ermit is issuet1 I sha I not
employ any person in any manner so a to -ore, subject to the Workers' Compen ation
Laws of California.
Date Owner
NOTICE TO APPLICANT: It, after making fgl[is Certificate of Exemption you should become
subject to the Workers' Compensation proJisior1s of the Labor Code, you must forthwith
Comply with such provisions or this permit shall be dgemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives sof this city to enter the above-
mentioned property for inspection purposes.
Signature of adplicant Date
Mailing Address
City, State, Zip
Sq. Ft. No.
Size Sto
No. Dw.
Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
PERMIT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.1.
Driveway Enc.
Infrastructure
TOTAL
REMARKS
AMOUNT
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side StreeeSetback from Center Line
Side Setback from Property Lin�>
FINAL DATE —INSPECTOR -
Issued by: Date_ ---- — _IAV/(IPeymi� 9
Validated by: � /9
Validation:
WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION
11.4
~ Desert Sands Unified School District
Notice: 82-879 Highway 1.11:
Document Cannot Be Duplicated Indio, CA 92201 ;
619-775-3500
CERTIFICATE OF COMPLIANCE
Date 1/14/98 631-820-023&024
No. 16490 Jurisdiction 'La Quinta
Owner Name Glenn'Sather - Permit #
No. •77380 Street Vista Rosa Log # '
City La Quints .';Zip 92253 Study.Area
Tract # .Lot # Square Footage 4750 ,
------------
Type of Development Single Family Residence No. of Units 1
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patios/walkways, residential additions under,500 square feet, detached accessory structures or replacement mobilehomes.
It has been determined the above-named owner is exempt from paying school fees at this time due to the following
reason:
.4 .
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government- Code 53080 in the amount of
1.84. X 4,750 or $.8,740..00 the property listed above and tliat building
permits and/or Certificates of.Occupancy for this square footage in this proposed project may now be issued,
Fees Paid By cc/Valley lndependent Bank/Glenn Sather --J TeleOlfbfie 771-11,941 ,
Name on the check'' r
' ,•,�� r•.� `" � 1,.I
By Dr. Doris Wilson
Superintendents
Fee collected /exempted by r Pauline Pearson Payment Received If•°` $8;740:00
,.
Check No. ,158005
Signature k -
OTICE: Pursuant of Assembly Bill 3081 (CHAP 549, sTATs. 1996) this will serve to•notify you that the 90 -day approval period in which you may protest the fees or other payment identified
bove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
?llect them.on the District('s)(s') behalf, whichever is earlier. -
Collector: Attach a copy of county or•city plan check application form to district copy for all waivers:
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
4
lesell
�.111.1g1,11N,llf
/
January21, 1998
IA
3 Sparks Construction
Attn: Grady.. Sparks
...rt.. �_ PO.,Box
La Quinta, CA 92253.
Re: Enclave Mountain Estates, Lots 47 and ,,48
Dear Mr. Sparks,
Y The Enclave Mountain Estates Architectural Committee has reviewed and approved the
recent submittal of working drawings from John Walling subject to the following
n n
comments:
- L Site drainage needs'to he handled on the site itself. Per the guidelines, there must
'.be a means of achieving positive.drainage from all locations on and under the
homesite to an approved drainage location. Your engineer can work with our '
consulting architect on the details
..
2. .`.Stucco�finish sample should be provided f6f' roval . K"
s
_ 3.Provide cut`sheets of exterior sconces and visible light fixtures forapproval.
.. :., �',��'•i'•G�s �� � .,,j. Y�'..s�--�.-. ... �.oir ±�i�... ,ti :�� �T;-. - _- .�..a,ti>_`�.. ti'..•,i .- � �..,
�T"i`, .��7 ,..-� ..
We are in receipt of the $10,000.00 construction performance bond. You may begin
construction nowr Thank you for your patience in the review process, I look forward to
_ working with you further on the`development of this residence.,
,
•
4• F {• Y T i'f.N f?
Sincerely ;err
r,�-y
Marian,Adkins, Property Manager
°Enclave Mountain Estates Homeowners Association Y
`
- ' ` •. � 1 e'er � h ' N
<+ Y, ,
••' 1 .� /d
.. .
}}
4 �
AS •
_
AgmL
ti Post Office Box 4772 .,� Palm Desert, CA 92261-4772
_ 73=550 Alessandro, Suite 5 Palm Desert, -California } {760) 346-1.161 • .FAX (760) 346-9918
AmeEl
W�am
AtOV-20-97 THU 04:23 PM COCKRELL ELECTRIC FAX
NO, 7608646235 P,02
SINGLE FAMILY' DW ELLING LOAD CALCULATION
FOR:,'.
MR. & MRS. SATHER
LOTS 447 & 48
THE ENCLAVE MOUNTAIN ESTATES
LA QUINTA, CA 92253
4750 SQ_. FEET AT 3 VOLT - AMPERES
14,250 VOLT - AMPERES
TWO 20. - ANIPERE APPLIANCE OUTLET CIRCI'ITS
AT 1500 VOLT - AMPERES,EACH
3,000 VOLT - AMPERES
LAUNDRY CIRCliIT
1,00 VOLT - AMPERES
DRYER CIRCUIT
5,000 VOLT - AMPERES
RANGE
9,120 VOLT - AMPERES
COOK TOP
7,600 VOLT - AMPERES
DISHWASHERl
Boa VOLT - :IMPERES
DISPOSAL
700 VOLT - AMPERES
W. CROWAVI✓
1,500 VOLT - A.MPERES
WATER HEATER"
VOLT - AMPERES
FURNACE UNIT 71
1,500 VOLT - AMPERES
FUP-N.ACF,T NIT =2
1,500. VOLT - :kMPERES
FURNACE UNIT 431,500
VOLT - A'VIPERES
POOL EQUIPMLEVT
10560 VOLT -AMPERES
LANDSCAPE LIGHTING
7,200 VOLT - AiNIPERES
66,130 VOLT -AMPERES
FIRST 10 kVA OF OTHER LOAD AT 100°'0
10,000 VOLT - AMPERES
REl bUNNDER OF OTHER LOAD AT 40°x0
22,452 VOLT - AMPERES
VOLT -AMPERES
'FUTURE LOAD DEiylAND, AT 1004%0 _ `
8;000 VOLT - AMPERES
AIR CONDITIONER # 1
8,400 VOLT - AMPERES
AIR CONDITIONER r 2
8.400 VOLT- AMPERES
:SIR CONDITIONER
8,400 VOLT - Av1PERES
TOTAL LOAD 65,652 VOLT AMPERES
65,652 V A - 240 VOLTS - 274 AWS
THEREFORE THIS DWELLING SHALL BE PERMITTED TO BE SERVED BY A 400
AMPERE SERVICE.
R ' 'OV -20-97 THU 04:24 PM COCKRELL ELECTRIC FAX NO. 760864623.5 P.03
ot
Sladden Engineering
6782 Stanton Ave., Suite E, Buena Park, CA 90621 (310) 864-4121 (714) 523-0952 Fax (714) 523-1369
39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (619)772-3893 Fax (619) 772-3895
March 3, 1998 Project No. 522-8016
Sparks Construction
P.O. Box, 1716
La Quinta, California 92253 _ -
Project: Lots 47 & 48 - Mountain Estates
77-380.Vista Rosa
La Quinta, California
Subject: lfesults of In -Place Density Tests
Building Pad.Grading
Summarized in this report are our; observations and the results of in-place density tests
performed as requested at the subject site during the"grading of the building pad for the
proposed single family residence. The site is located on lots 47 and 48 of the Mountain
Estates development in the Santa Rosa Cove area of La,Quinta, California. Pad Grading
was performed by Nuevo Engineering using conventional heavy equipment.
The building pad area was overexcavated to a depth of approximately three feet below
pad grade. The bottom of the excavation was scarified, moisture conditioned and
recompacted prior to fill placement. The previously removed engineered fill material was
placed in thin lifts at near optimum moisture content and compacted to at least 90 percent
-reiative,compaction. Some import material was required to achieve the desired grade. The
import sand was obtained from Granite Construction Company. Overexcavation and
recompaction extended to a lateral distance of five feet beyond the building limits.
Observations and field testing were performed on February, 20, 1998 and February 26,
1998. The excavation bottoms were approved prior to fill placement. Testing indicates .
that a minimum of 90 percent relative compaction was attained in the areas tested. The
passing test results indicate compliance with the project specifications at the tested
locations and depths but are no guarantee or warranty of the contractor's work.
Field Tests: In-place moisture/density tests were performed using a nuclear density
gauge in accordance with test methods ASTM D 2922 and ASTM D 3017. A total of 18
tests were performed. " The approximate test locations are indicated on the attached plan
and test results are'summarized on the attached data sheets.
4
I,?
t
,March 3, 1998 ~ ' (2) Project No. 522-8016
Laboratory Tests: The moisture -density relationships for the tested materials were
determined in the laboratory in accordance with test method ASTM D 1557-91.
Laboratory test results are summarized on the attached data sheet.
Allowable Bearing Pressures: The structural values recommended in the initial Soil
Engineering Report and addendums prepared by Buena Engineers and confirmed in the
Geotechnical Update prepared -by. Sladden Engineering (Project No. 544-8009, dated
February 2, 1998) remain applicable for use in foundation design. Conventional shallow
spread footings should be bottomed,in properly compacted fill material a minimum of 12
inches below lowest adjacent grade. Continuous footings should be at least 12 inches
wide and isolated pad footings should be at least two feet wide. Continuous footings and
isolated pad footings may be designed utilizing allowable bearing pressures of 1500 psf
and 1800 psf, respectively. The recommended allowable bearing pressures may be
increased by one-third for wind andseismic loading.
The surface soils consist of imported sands that are non -expansive and fall within the
"very low" expansion category in accordance_ with. Uniform Building Code (UBC)
classification criteria.
A sample of the surface sand was obtained and delivered to Anaheim Test Laboratory for
soluble sulfate. testing. _ Soluble sulfate content was determined in accordance with
California Test Method No. 417. Testing indicated a soluble sulfate content of 107 parts
per million. The low sulfate content indicates that the normal Type.2 cement should be
adequate and the use of Type 5 'cement or special sulfate resistant concrete mix. designs
should not be necessary.
a
If there are any questions regarding this report or the testing summarized herein, please
contact the undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Anderson u
Principal Engineer�U
Copies: 4- Sparks Construction
Sladden Engineering
of
March 3, 1998
.: (3)
Project No. 522-8016
+ Test
Tested
Moist Cont
Dry Den. Max Dry Den
Percent
No. Date Location
Depth
Percent
Lbs/Cu Ft Lbs/Cu Ft
Rel Comte
Building Pad
1 2/20/98 " Per Plan
3.5 BPG,
8.9
117:4 '
118.5
99
2, 2/20/98 Per Plan
3.5 BPG
11.7
115.2
118.5
97
3 2/20/98 Per Plan
4.0 BPG
• 12.2
113.5
118.5
96
4 2/20/98 Per Plan
3.0 BPG
7.9
113:8
118.5
96
5 2/20/98 Per Plan
3.0 BPG
7.5
103.5 _
118.5
91
6 2/20/98 Per Plan
3.0-BPG
5.6
107.6
118:5
91
7 2/20/98 Per Plan
3.0 BPG
6.9 R
107.9
118.5
91
8 .2/20/98 Per Plan
2.0 BPG
7.2
113.8 a
118.0
96
9 2/20/98 Per Plan
:,2.0 BPG
8.1:.
117.7
118.0
99
10 2/20/98 'Pei Plan,
1.5 BPG
6.6.
113.5
118.0
96
11 2/20/98 Per Plan
1.5 BPG
. 6.8
113.9
118.0
96 "
12 2/26/98 Per Plan'
1.0 BPG
6.9
" 114.4
118.0
97
13 2/26/98 Per Plan
1.0 BPG
'. 8.3 R
114.6'
118.0
97
14 2/26/98 Per Plan
1.0 BPG
7.8
115.7
118.0
98
15 2/26/98 Per Plan
PG
8.5
123:.1
126.5
97
16 2/26/98 Per Plan
;. PG
7.9
',122-.'8
126.5
97
17 2/26/98 PerPlana ,
0.5'BPG
. `8.0 "
122.0
126.5
96
.18 2/26/98 Per Plan
PG ..
7.3
116.9
126.5
92
Laboratory Test Results:
`
Brown sandy clayey silt (ML)
Maximum Dry Density - 118.5
pcf / Optimum Moisture
Content -
12.2%
Light brown fine grained sand (SP)
Maximum Dry Density - 118.0
pcf / Optimum Moisture Content -
12.8%
Light brown fine to coarse grained sand (import -Granite)
.
Maximum Dry Density - 126.5 pcf / Optimum Moisture- Content -
8.1 %
Slodden Engineering
WALLING & McCALLLIM / LIMITED
ARCHITECTURE • PLANNING •.ENGINEERING'
46-1130 CLUB DRIVE -+. . 1678) 360-OS60 .,,..
INDIAN WELLS. CA 922`10 PAX 16191380-07813
.. moi. i......• 'S t� �` ter, ..
i i d1 �1•N ../' ..
- GRADING ADDENDUM
of
.,r, (� .Li'l. I iyi.�: /'•� '} 1l` .F-, } ...
Sather Residence
a
Lots 47 and 48, The Enclave Mountain Estates; La Quinta
1.). Building areas to receive "more than one (1). -foot of fill should be overexcavated to. "idepth of
two (2) feet below existing grade. `+The. :exposed surface' should,Abe scanfied,'�moisture a
conditioned and recompacted by means .of heavy vibratory equipment so that' a'minunum of
ninety (90) percent of maximum density is obtained.. ..,Thepreviously 'removed'soils and'any fill
material should then be placed in eight (8) inch layers in a -loose condition'at or near optimum 7
moisture- andcompacted to; a minimum of ninety (90) percento£maxunum density t
`,- 2.) , Building areas to receive less than one-(1);foot of filland building areas that are iri cut areasf
,.
should be overexcavated to a depth of two. (2) feet below,the;bottom,,of.the footings ,' The s
d
., t
exposed surface should be scarified; moisture.,conditioned acid recompacted with heavy vibratory,
. _ _ ,
' equipment so that a minimum of ninety'(90) percent, of maximum: density.is, ` obtained ..The i {.
previously removed soils and any fill material should then'Wplaced in .thin layers,at near":`
optimum moisture and compacted to a minimum of ninety (90) percent- of maximum density.
The intent is to have three (3) feet of soil compacted to' a'minimuM. of ninety (90),percent of
maximum density compose the building pad beneath' the flootings:'. ' Compaction' is to. be
confirmed by testing.
3.) These grading requirements apply to building areas and at least five (5) feet;beyond building= n ,
limits. r
r
/ �4
REVISED TITLE 24,
Energy Conservation
Standards�
S 1
fi4t,.11P
)
CUSTO t RESIDENCEF
MR. & MR �E � , , -A Hu
L 'TS 47
THE ENC UNTAIN
ESTATES
July 22, ,1998. Job Number: 17285B
Prepared For. -
WALLING & McCALLUM LTD
45-190 1CLUB DRIVE
INDIAN WELLS, CA 92210
e �
Ma a,4 it s
enterprises
vvvvvvvl
Catherine M. Madlin, Certified Energy Analyst
Post Office Box 1443 e Palm Springs, CA 92263
760-322-5004 / 323-3644 (fax)
E-mail: CVladlin@aol.com
' - Madlin's
y enie mes
Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ® ®
vvvvv
Title 24 Energy Conservation Standards
µ. Compliance Report
This proposed project has been reviewed for compliance with the 1995 State, of California
Energy Conservation Standards, Title. 24, by Madlin's Enterprises. The building design
described in this compliance portfolio is in conformance with the standards as outlined in
the. attached compliance forms and documentation.
Date: July 22, 1998 i
Job Number: 17285B'
T
Prepared For: WALLING & McCALLUM LTD .
Owner's Name: MR. & MRS. GLENN SATHER
Project,Name: CUSTOM RESIDENCE FOR MR. & MRS. GLENN SATHER
Project Location:. LOTS 47 & 48 - THE ENCLAVE MOUNTAIN ESTATES
Method of Compliance:. MICROPAS V4.5 CERTIFIED COMPUTER PROGRAM
Orientation Of Entry:' .WEST (250 Degrees)
Certified Ener
gy Ane.lyst
Cati erir:e M. Madlin
- f NR 92-90-544
r r `Y R 92-90-144
r
rt
C A B E C
California Association of 103uiltling Energy Conwltants
V Post Office Box 1443 ® Palm Springs, Ca 92263 v
{
Ar
madlin�s
ente fines
Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323.-3644 (fax) ®V ®V ®®
::.:::................:::::.: Q,.;.....C�F TJI DIN x„G(JMPQNE T
.............
N�IlV GC7M) LIM. RE UIl2EMEN1
Q ::::::.. .
Job Name
SATHER RESIDENCE
Job No. / File No.
17285B
Method of Compliance
Micropas 4.5 Computer Simulation
Total Conditioned Square Footage
4777 Sq. Ft:
Total Glazing % (Floor/Glass Area Ratio)
28.9% .
Insulation: Roof / Ceiling
R-38
Insulation: Walls
R-21
Insulation: Floor - Slab on Grade
None Required
Insulation: H.V.A.C. Ducts/.Location
R-4.2 / Attic
Glazing U Value / Type: Operable
0.87, Dual,” Alum. Frame (CEC Default Value)
Glazing U -Value / Type: Fixed"
-
0.59, Dual, Alum. Frame
Fleetwood Norwood 3000 with Low E
Glazing U -Value / Type: Patio
0.65, Dual, Alum. Frame
Fleetwood Norwood 3000 with Low E
Glazing U -Value / Type: Glass Block
0.57 (CEC Default Value)
Glazing U -Value / Type: Skylights
0.80 Dual Domed (CEC Default Value)
Glazing- Shade Coefficient (TINT)
Tinted 0.57 SC
Glazing: Exterior Shading
Overhangs as Shown
Glazing: Interior Shading
Blinds'Light and Roller Shades - See C -2R for
specific window. locations
Thermal Mass Square Footage
1526 Sq.Ft.
Thermal Mass % (Floor Area/Mass Area Ratio)
32%
H.UiA.C. System Type
Gas Heating / Electric Cooling
HVAC System Efficiencies (heating/cooling)
800/, AFUE /` 12.0 SEER
Domestic Hot Water Heater
(2) 50 Gal. Gas
Energy Factor / Eff. / Standby Loss
.60 or better
R12� Blanket on Tank
No
Recirculating Pump for DHW
Yes with time & temperature controls
Madlin s
enterpnses
Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) . ®V V V
Thermal Mass Schedule
Date: July 22, 1998
Job Number: 17285 B
Prepared For: WALLING & McCALLUM LTD
Project Name: RESIDENCE FOR MR.•& MRS. GLENN,SATHER
The following mass data was included in, the: attached Title 24 calculations to assist "this project in demonstrating
compliance with the standards:
NOTES:
1. Pursuant" to the standards, areas under cabinets and closets are not included in the square footage figure
listed above.
2. _The hard surface listed in the descriptioncolumn above may be ceramic'tile, vinyl tile, marble, or paint
directly applied to the heavyweight concrete slab.
I , All surfaces covered by_ carpet, cabinets, or walls are included in the attached calculations as covered
mass.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
------------------------ ----
Project Title.......... WALLING.SATHER RES. Date........ 07/22/98
Project Address......:. Lot 47 & 48 - The Enclave******* ---------------------
La Quinta, Ca *v4.50*
Documentation Author... CATHERINE M. MADLIN Buliding Permit
Madlin's Enterprises
P.O. Box 1443 Pian CneCk / 1)a e
Palm Springs, CA 92262.
619-324-1731 k1eia Cneck/Date
Climate Zone.........:. 15` ----------- ---------
Compliance Method....'.. MICROPAS4 v4.50 for.1995,Standards by Enercomp,"Inc.
-------------------------------------------------------- -----------------------
-------------------------------------------------------------------------------
MICROPAS4 v4.50 File -17285B1 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run-REVISED.CALCULATION I
-------------------------------------------------------------------------------
GENERAL INFORMATION
r
Conditioned Floor Area..... 4777 sf
Building
Type ..............
Single
Family Detached
Construction
Type .........
New
Building
Front Orientation. Front Facing
250 deg (W)
Number of
Dwelling Units...
1
Number of
Stories. ......
1
Floor Construction
Type....
Slab On
Grade
Glazing Percentage.........
28.9 %
of floor area
Average Glazing
Um -value ....
0.62 Btu/hr-sf-F
BUILDING
SHELL INSULATION
Component
Frame
-------------------------
Cavity Sheathing
Insul
Assembly
Type
Type
-------
R -value R -value
----------------
R -value
-------------
------
U -value Location/Comments
-------
Wall
Wood
R-21 R-0
R-21
------------------------
0.059
Door
Wood
R-0 R-n/a
R-0
0.330
Roof
Wood
R-11 R-27
R-38
0.025
S1abEdge
n/a
R-0 'R-n/a
• R-0
0.900
S1abEdge
n/a
R-0 R- n/a
R-0
0.720
S1abEdge
n/a
R-0 R-n/a.
R-0
0.550
SlabEdge
n/a
R,-0 R.-n/a
. R-0
0.500
FENESTRATION
------------
# of
Interior
Over -
Area U- Pan-
Shading/
Exterior
hang/
Framing
Orientation
(sf) Value es
Description Shading
Fins
Type
-------------------
Window
Front W)
----- ----- ----
24.0 0.590 2
---------------
Blinds.Lt
-----------
None
----
Yes
---------
Metal
Door.
Left N
56.0 0.650 2
Blinds.Lt
50% bug scr
Yes
Metal
Window
Front NW
26.0 0.590 2
Roller.Lt
None
Yes
Metal
Window
Front NW
60.0 0.590 2
Blinds.Lt
None
Yes
Metal
Window
Right SW
45.0 0.590 2
Roller.Lt
None
Yes
Metal
Window
Back SE
12.5.0.570 2
Roller.Lt
None
Yes
None
Window.
Right SW
19.5 0.590 2
Blinds.Lt.
None
Yes
Metal
Window
Back SE
10.5 0.570 2
Roller.Lt
None
Yes
None
Window
Back SE
20.0 0.590 2
Roller.Lt
None
Yes
Metal
Door
Right SW
80.0 0.650 2,
Blinds.Lt
50% bug scr
Yes
Metal
Window
Front NW
24.0 0.590 2
Blinds.Lt
None'
Yes
Metal
Door
Left NE
56.0 0.650 2
Blinds.Lt
50% bug scr
Yes
Metal
Window
Front NW
10.5 0.570 2
Roller.Lt
None
Yes
None
r
CERTIFICATE OF
COMPLIANCE:
RESIDENTIAL
Page 2
CF-1R
-------------------------------------------------------------------------------
Project Title...........
WALLING.SATHER RES.
-------------------------------------------------------
Date.........
07/22/98
Wth-CTZ15S92
Program=FORM CF -1R
-----MICROPAS4v450--File-17285B1
User#-MP0207
User-Madlin's Enterprises.
Run -REVISED CALCULATION
FENESTRATION.
------------
# of Interior
Over -
Area U-
Pan- Shading/
Exterior-
hang/
Framing
Orientation
(sf) Value
es Description
Shading
Fins
Type'
-------------------
Window Front
NW
------ -----------
16.0 0.590
-------------,--------------
2 Blinds.Lt
None
----
Yes
---------
Metal
Window Left
NE
36.0 0.590
2 Blinds. -Lt'
None
Yes
Metal
Window Back
SE
36.0 0.590
2 Blinds.Lt"'
None
Yes
Metal
Door Back
S.E
80.0-0'650
2 Blinds.Lt
50% -bug scr
Yes
Metal
Door Left.
NE
140.0.0.650
2 Blinds.Lt ..
50% bug scr
Yes
Metal
Window Back
E
70.0'0.590
-2 Blinds.Lt
None
Yes
Metal
Door Back
E
140:-0 0`.650
2 Blinds.Lt�
50% bug scr
Yes
Metal
Window Back
E
70..0 0:•590
2 Blinds.Lt.
None
Yes-
Metal
Window Right
S
ISI
60.0 0.590
2 Blinds.Lt'_
None
Yes
Metal
Door Back
E
96•.0`0.650
2 Blinds.Lt
`50% bug scr
Yes
Metal
Window ' Right
36.0 0.590
2 Blinds.Lt
`-None
Yes
Metal
Window Back
E
40.5 0.'590
2, Roller.Lt
None .'
Yes
Metal
Window Right
S
40.5 0.590
2 Roller.Lt3
None
Yes
Metal
Window, Right
S
10.5 0.570
2` Roller..Lt
None
Yes
None
.Skylight Horz
4.0 0.800
2 'Medium wht
None
Yes
Metal
_ Skylight Horz,
4.0 0.800
2 Medium wht
None'
Yes
Metal
Window Left
N)
12.3 0.590
-2. Blinds..Lt
None
Yes
Metal
Window Left
NE)
21.0.0.590
-2 Blinds.Lt
None
Yes
Metal
Window Back
E)
12.3:•0-.590
2 Blinds.Lt..
None
Yes
Metal
- Window Right
SW)
12.7 0.590
2 Blinds.Lt',,
None
None
Metal
_- -
THERMAL MASS
------------
Area- Thickness
Type:
---
------------
Exposed '
(sf), (in)
------
.,Location/Comments
. S1abonGrade
Yes
-------.------------------------
? .1526 3.5 .'
SEE SCHEDULE
SlabOnGrade
No
3251 3.5,
InteriorVert
Yes
250. 1.0`
InteriorHorz,
Yes
250 1.0
HVAC SYSTEMS
----------
Minimum y Duct y
Duct Thermostat
Equipment
Type -Efficiency • Location
---------- -------------
R -value Type,
Furnace
0.800 AFUE Attic
------- --.----------
R-4.2 Setback
ACSplit
-
12.00"SEER, Attic
R-4.2 Setback
.
-
.
�t
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3
CF-1R
-------------------------------------------------------------------------------
Project Title.......... WALLING.SATHER RES. Date........
07/22/98
MICROPAS4 v4.50 File-17285B1- Wth-CTZ15S92 Program-FORM CF-1R
I User#-MP0207 User-Madlin's Enterprises Run-REVISED CALCULATION
-WATER- HEATING SYSTEMS
;.
---------------------
Number Tank
External
in Energy Site
Insulation
Tank Type, Heater"Type °'Distribution Type System Factor (gal)
------------------
R-value
-------------- ------
Storage Gas Recirc/Time'Temp .2 0.60 EF 50
--- ------
R-0
SPECIAL FEATURES/REMARKS
------------------------
Tinted Glazing.
Fixed and patio doors - Fleetwood -Norwood 3000 with Low E
The values and materials used.in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his option) install
better materials without additional compliance calculations.
The installing hvac contractor shall provide the required CF-6R
with the installed hvac equipment model numbers.
A'Night setback thermostat.is required to be installed with the
HVAC system.
For additional information on the proposed thermal mass locations .
see the Mass Schedule and Notes in this compliance report.
The installed plumber.shall provide the-required CF-6R listing'
the water heater model number,(s) and the certified plumbing
fixtures.-
ri
1
4 -
CERTIFICATE OF.COMPLIANCE::RESIDENTIAL Page 4 CF-1R
________________---------
_______________________
Project Title.......... WALLING.SATHER RES. -Date ......... 07/22/98
I MICROPAS4 v4.50 File-17285B1 Wth-CTZ15S92 Program-FORM CF-1R
--- User#-MP0207 User-Madlin's Enterprises Run-REVISED CALCULATION
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building features'and performance
'specifications needed to comply with Title-24i Parts'l and 6 of the
California Code of Regulations' and the 'administrative regulations to�
implement them. This certificate has been signed by the ind-ividual with
overall design respponsibility. When this certificate of- compliance is
submitted 'for a single.building plan ,to be built in-multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section. ;k n
DESIGNER or OWNERF,. DOCUMENTATION AUTHOR
Name..— John Walling Name.... CATHERINE M. MADLIN
Company. Walling & McCallum Ltd Company, Madlin's Enterprises
Address. 45-190 Club Dr. Address., P.O:-Box 1443
Indian Wells, Ca., Palm Springs, CA 92262
Phone... 760-360-0250., Phone. 6t9=324-1731
License.,
Signed..
Signed.
(clate)ry 4 a e
ENFORCEMENT AGENCY
Name. Certified" Energy° Anaayet
Title...
Agency.. CathariniM.- 6adlin
NR 92-90-544
Phone... � � R 92-90-14
Signed.. '- ri
®E
a e Cal fomic Assodotion of BuildingEne
rgy.Conwitcnts
...
41
Mandatory Features & Devices Checklist: Residential MF -1 R
DOCUMENTATION AUTHOR: MADLIN'S ENTERPRISES
CERTIFIED ENERGY ANALYST: CATHERINE M. MADLIN
TELEPHONE NUMBER: 764322-5004 / 323-3644 FAX
For Enforcement Agency Use Only
Building Permit Number
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach. items marked with
an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist Is incorporated
Into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for :the
mandatory measures whether they are shown elsewhere In the documents or on this checklist only.
BUILDING ENVELOPE MEASURES BLDG.DEPT.
• §150(a): Minimum R-19 ceiling insulation ........... .
• .§150(b): Loose fill insulation manufacturer's labeled R -Value
• §150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass) ........
• §150(d): Minimum raised floor insulation: R-13 framed floors; R-8 concrete raised floors .. . ... .
• §150(1): Slab edge insulation - meets maximum water absorption rate & water vapor transmission rate
• §118: Insulation specified or installed meets C.E.C. quality standards. Indicate type and form.
• §166-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls . ............ .
a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage
b. Manufactured fenestration products have label with certified U -value, and infiltration certification
c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed
• §150(g): Vapor barriers mandatory in Climate Zones ,14 and 16 only ...... , ...... .
• §150(f); Special infiltration barrier installed to comply with §151 meets Commission quality standards
• §150(e): Installation of Fireplaces, Decorative Gas Appliances and .Gas Logs ................
1. Masonryand factory -built fireplaces have:
a. Closeable meatal or glass door.
b. Outside air intake with damper and control.
c. Flue damper and control.
2. No oontinuous-burning gas pilots allowed.
SPACE CONDITIONING, WATER HEATING ANDPLUMBING SYSTEM MEASURES.
• §110-13: HVAC equipment, water heater, showerhead and faucets certified by the commission ...
• §150(i): Setback thermostat on all applicable heating systems . ...................... .
• §1500): Pipe and Tank Insulation ...................... ....................... .
1. Indirect hot water tanks have insulation blanket R-12 or greater or combined intJext. R-16 or greater.
2. First 5 feet of pipes closest to water heater tank, non recirculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating sections of hot water system.
4. Cooling system piping below 55°F insulated.
5. Piping insulated between heating source and indirect hot water tank.
• §150(m): Ducts and Fans ........ ..................... ........... .
1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value of R-4.2 or ducts enclosed entirely with conditioned space.
2. Exhaust fan system have backdraft or automatic dampers
3. Gravity' ventilating systems shall have automatic or readily accessible, manually operated.dampers.
• §114: Pool and Spa. Heating Systems and Equipment ..................................
1. System shall be 78% thermal efficiency, have anon -off switch, & weatherproof operating instructions.
No electric. resistance heating and no pilot light.
2. System is installed with:
a. At least 36° pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and circulation pump time switch.
• §115: Gas-fired fau, pool heater, spa heater or household cooling appliance have no continuously
burning pilot light. (Exception: Non -electrical cooling appliance with pilot < 150 btu/hr.) ....... .
LIGHTING MEASURES
• §150(k): 40 lumens /watt or greater for general lighting in kitchens and rooms with water closets; and
recessed ceiling fixtures IC (insulation cover) approved ........... ............. .
COMPUTER METHOD SUMMARY Page 1 C-2R
------------------------------------------------------=------------------------
Project Title........... WALLING.SATHER RES. "Date........ 07/22/98
Project Address........ Lot 47 & 48 - The Enclave******* ---------------------
•'La Quinta, Ca_ *v4.50*
Documentation Author... CATHERINE M. MADLIN Buliding Permit
Madlin's Enterprises
P.O.; Box 1443 Flan. Check D-a-fe
Palm Springs, CA 92262
619-324-1731 Fleid Check/.Date
Climate Zone........... 15 ---------------------
Compliance Method::,.... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc.
MICROPAS4 x4.50 File -17285B1 Wth-CTZ15S92 Program -,FORM C-'2R
--------User#_MP0207 User-Madlin's Enterprises Run. -REVISED CALCULATION
----------=-------=----------------------------------------
MICROPAS4 ENERGY USE SUMMARY _
------------------- --------- -
Energy Use Standard. 'Proposed Compliance
_ (kBtu/sf-yr.) Design, Design Margin =
--- -----.----r --------- ----------
Space Heating. .. 3.19 3. 03 0.16' _
= Space Cooling. .. 28.88 27.55 133 =
= Water Heating.. .. `.. 5.47. 6.41 -0..94 =
= Total .37.54 -.36.99- ---0.55 =
_ ***Building complies with Computer Performance-*** _
----------------
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 4777`sf
Building Type. .......... Single Family Detached`
Construction Type.. New
Building Front Orientation. Front,Facing 250 deg (W)
Number of Dwelling Units... 1
Number`of Building Stories. 1 i
Weather Data Type.......... .FullYear-
Floor Construction Type,.,..- Slab On Grade ;
Number of Building Zones. 1
Conditioned Volume... 52547-cf
Footprint Area....... 4777 sf. '
Ground Floor Area... ..... 4777 sf
Slab -On -Grade Area... ... 4777 sf
Glazing Percentage.......... 28.9 A of floor area
Average Glazing.U-value.... 0•.62 Btu/hr-sf-F
Average Ceiling Height.....11 ft`
a�
COMPUTER METHOD SUMMARY Page 2 C-2R
Project Title....:..... WALLING.SATHER RES.Date........ 07/22/98
I-----MICROPAS4-v450 File -17285B1 wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -REVISED CALCULATION
BUILDING ZONE INFORMATION
=------------=------=-'--
Floor. # of Vent Special
Area.. Volume Dwell Cond- Thermostat Height Vent Area
Zone Type (,sf) (cf) - :Units itioned Type (ft) (sf)
-----------,---=--------- ---- --------------
----- ----- -----
HOUSE -------------- -
Residence 4777 52547 1.00 Yes Setback 2.0 n/a
OPAQUE SURFACES
---------------
Area U- Insul Act Solar. Form 3 Location/
Surface (sf) ,value R-val Azm Tilt Gains Reference Comments
----- ----- --- ---- -
------------------ ----------------
HOUSE ----------------
HOUSE -
1 Wall 361 0.059 21 250 .90 Yes W.21..2X6.16
2 Wall 2.7.1 0.059 21 340. 90 Yes .:W.21.2X6.16
3 Wall 262 0.059 21 70- 90 Yes W.21.2X6.16
4 Wall 615 0.059 2.1 160 90 Yes W.21.2X6.16
5 Wall 568 0.059 21 250• 90 No W.21.2X6.16
6 Wall 569 0.059 21 295 90 Yes W.21.2X6.16
7 Wall 257 0.059 21 25- 90 Yes W.21.2X6 16
8 Wall 243 0.059 21 115 90 Yes W.21.2X6.16
9 Wall 198 0.059 21 205 90 Yes •W.21.2X6.16
10 Door 60 0.330 0' 250 190 Yes None
11 Door 20 0.330 0 25.0 90 No None
12 Roof 4769 0.025.38 n/a 0 Yes 'R.38.2X4.24
PERIMETER LOSSES
Lenggth .F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------ --- --- ----- ---------------------
HOUSE
13 SlabEdge 45 0.900 R-0 No '
14 S1abEdge 137 0.720 -'R-0 No
15 S1abEdge 107, 0.550 R-0 No
16 SlabEdge 132 '0.500 R-0 No
FENESTRATION SURFACES
---------------------
# of Vent SC SC Interior
Area Pan Frame Open U- Act' Glass Int Shading/
Surface (sf) es Type -- Type value Azm Tlt Only Shade Description
----- .------- ------
----- --- --- ---- ---- ---------------
HOUSE
1 Window 24.0 2 Metal Std 0.590 250 90 0.70 0.58 Blinds.Lt
2 Door 56.0' 2 Metal Std 0.650 340 90 0.70 0.58 Blinds.Lt
3 Window 26,.0 21 Metal Std G.590 295 90 0.10 0.40 Roller:Lt
4 Window 60.0. 2 Metal Std 0:590 295 90 0.70 0.58 Blinds.Lt
5 Window 45.0 2 Metal Std 0.590 205 90 0.70 0.40 Roller.Lt
16 Window 12.5' 2 None Std 0.570.115 90 0:86 0.40 Roller.Lt
7 Window 19.5 2 Metal Std 0.590 205 90 0.70 0.58 Blinds.Lt
8 Window 10.5 °2' None Std 0.570 115 .,90 0.88 0.40 Roller..Lt
COMPUTER METHOD SUMMARY
Page -3
C-2R
Project Title..........
WALLING.SATHER
RES.
Date ........
Wth-CTZ15S92
Program
-FORM
-07/22/98
C -2R
User#-MP0207
----MICROPAS4-v450--File-17285B1
User-Madlin's
Enterprises
Run -REVISED
CALCULATION
FENESTRATION
SURFACES
# of
---------------------
Vent
SC
SC,
Interior
Area
Pan-
Frame
Open
U= Act
Glass
Int
Shading/
Surface
--
(sf-)
-----
es
Type
Type
value Azm
Tlt
Only
Shade
Description
9
Window
20.0
----
2
---------
Metal
------
Std
----- ---
0.590 115
--------
90
0.70
----
0.40
---------------.
Roller.Lt,
10
Door
80.0
.2
Metal
Std
0.650 205
90
0.70
0.58
Blinds.Lt
11
-Window
24.0
_2
Metal
Std
0.590 295
90
0.70'0.58
Blinds.Lt
12
Door,
56.0
2.
Metal
Std
0.650 25
90
0.70
0.58
Blinds.Lt
13
Window
10.5
2
None
Std
0.570 295
90
0.88
0.40
Roller.Lt
14
Window
16.0
2
Metal
Std
0.590 295
90
0.70
0.58
Blinds.Lt
15
Window
36.0
2
Metal
Std
0.59.0 25
90
-0.70
058
Blinds.Lt
16
Window.
36.0
2
Metal
Std
0.590 115
90
0.70
0.58
Blinds.Lt
17
Door
80.0
2
Metal
Std
•0.650 115
90
0.70
0.58
Blinds.Lt
18
Door.,
140.0
2
Metal
Std
-0.650 25
90
0.70
0.58
Blinds.Lt
19
Window
70.0
2
Metal
Std
0.590 70
90
0.70
0.58
Blinds.Lt
20
Door
140.0
2
Metal
Std
-0.650 70
90
0.70.0.58
Blinds.Lt
21
Window
70.0
2
Metal"
Std
0.590 '70,
90
0.70
0.58
Blinds.Lt
22
Window
60.0
2
Metal
Std
0.590 160
90
0.70-0.58
Blinds.Lt
23
Door
96.0
2
Metal
Std
0.650' 70
90
0.-70
0.58
Blinds.Lt
24
Window
36.0
2
Metal'
Std- "
0.590 160
90
0.70
0..58
Blinds.Lt
25
Window
40.5
2
Metal-
: .Std
0.590 70
90
0.70
0.40
Roller.Lt
26
Window
40.5
2
Metal
Std
0.590 160-
90
0.70
0.40
Roller.Lt
27
Window
10.5
2
None
Std
0.570.160
90
0.88'0.40
Roller.Lt
28
Skylight
4.0
2
Metal
Std
0.800 250
0
0.36
0.36
Medium wht
29
Skylight
4.0
2
Metal
Std
0.80.0:250
0
0.36
0.36
Medium wht
30
Window
12.3
2
Metal
Std
0.590'340
90
0.70
0.58
Blinds.Lt
31
Window
21.0
2
Metal
Std.
0.590 25
90
0.70
0.58
Blinds.Lt
32
Window
12.3
2
Metal.
Std
0.590 70
90
0.70
0.58
Blinds.Lt
33
Window
12.7
2
Metal
Std
0.590'205
90
0..70
0.58
Blinds.Lt
OVERHANGS
AND SIDE FINS
,
--- Window--
-------------------
----=-overhang---------
Left
Fin---
---Right
Fin --
Area.
Left Rght
Surface
(sf)
---
Hght
-----
Wdth
-----
Dpth Hght
---- ----
Ext Ext,
----
Ext
Dpth
Hght
Ext Dpth
Hght
HOUSE
,
-- ----
----
1
Window
24.0
8
.'3
'3 0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
.2
Door
56.0
8'
7
3 0
n/an/a
n/a
n/a
-n/a
n/a n/a
n/a
3
Window
26.0
7.5
3.5
2 0
'n/a n/a"
n/a
n/a
n/a
n/a n/a
n/a
4
Window
60.07.5
8
.2.5 0
n/a n/a..
n/a
n/a
n/a
n/a n/a
n/a
5
Window
45.0
7.5•
6
3 0
n/a n/a
-n/a
n/a
n/a
n/a n/a
n/a
7 -Window
19.5
6.5
'3
4 0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
8
Window
10.5
5.24,-2
5 0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
10
Door
80.0
8
10
3.5 0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
11
Window
24.0
8
,3.
7 0
n/a' n/a
n/a
n/a
n/a
n/a n/a
n/a
12
Door
56.0
8
7
9.5 0
n/a n/a_
n/a
n/a
n/a
n/a n/a
n/a
13
Window
10.5
5.34
2.
1.5 0 ..n/a
n/a
n/a
n/a
n/a
n/a n/a
n/a
14
Window
16.0
8
2
'4.5 0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
15
Window
36.0
6
6
1.1 0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
16
Window
36.0 .6
6
101 �0
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
17
Door
80.0
10
8
16.0
n/a n/a'
n/a
n/a
n/a
n/a n/a
n/a
COMPUTER METHOD SUMMARY
Page 4
Project Title.........----------------============_=_____________------C-2R
WALLING.SATHER RES. -------_
Date........ 07/22/98
I MICROPAS4 x4.50 File -17285B1 Wth-CTZ15S92_ Program -FORM C-2R
--------User#_MP0207 User-Madlin's Enterprises- Run -REVISED CALCULATION I
OVERHANGS AND SIDE FINS -
---Window-7 Overhang- - --Left Fin-- -
Area Left R --Right Fin--
Surface---- _ -- Hght- Wdth_ Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
18 Door 140.0 10 14. 13 ..0.
19 Window 70.0 10 7 n/a n/a n/a n/a n/a n/a n/a n/a
20 Door 140.0 10 14- 5 0 n/an/a n/a n/a n/a n/a n/a n/a
21 Window 70.010 7 5 0 n/a. n/a n/a n/a n/a n/a n/a n/a
22 Window 60.0 10 6 5 0 n/a n/a n/a- n/a n/a n/a n/a n/a
23 Door 4.5 0 - n/a n/a n/a n/a n/a n/a n/a n/a
96.0.8 12 4
24 Window .5 0 n/a n/a n/a n/a n/a n/a n/a n/a
36.0 8 4.5 12. 0 n/a•m /a1,n/a n/a n/a n/a n/a n/a
25 Window 40.5 6.5. 6.25 2 0 n/a n/a n/a n/a n/a n/a n/a n/a
26 Window 40.5 6.5 6.25 3.5 0 'n/a n/a n/a n/a n/a n/a n/a n/a,
30 Window 12.3 3.5 3.5 2 0 n/a
31 Window 21n/a n/a n/a n/a n/a n/a n/a
.0 3.5 6 6 01 n/a n/a n/a n/a n/a n/a n/a
32 Window 12.3 3.5 3.5 '4- 0 -, n/a nn/a
n/a n/a n/a n/a n/a n/a
EXTERIOR -SHADING
----------------
Area Shading SC of
Surface -(sf) Type Ext Shade
HOUSE
---------------- -----
r ----
2 Door • 56.0 50%'bug scrn 0.84
10 Door 80.0 50% bug scrn . 0.84
12 Door 56.0 50% bug scrn 0.84
17 Door 80.0 50%.bug scrn 0.84
18 Door ,140.0 50 bug scrn 0.84
20 Door ,x..140. 0 50% -bug scrn 0.84
23 Door 4.96.?0 5.0%..bug scrn 0.84
THERMAL MASS
_ .
Area Thick Heat_ Conduct- Surface
Mass Type--- (sf)_- .(in)Cap ivity R -value Location/Comments
HOUSE --=---------
'1 S1abOnGrade 1526% +3:5 28.0 0.98 'R-0.0 SEE SCHEDULE
2 SlabOnGrade 3251 3:5 28.0 '0.98 R-2.0
3 InteriorVert 250 1.0 24.0 TO.67 R-0.0
4 InteriorHorz 250 1.0 24.0 0.67 R-0.0
HVAC SYSTEMS
System T Minimum Duct Duct Duct
---------- -Efficiency- Location. R -value Efficiency
HOUSE ------------- ------
Furnace 0.800•AFUE Attic' R-4.2 0.830
ACSplit 12.00 SEER Attic
R-4.2 0.810
COMPUTER METHOD SUMMARY • Page 5
C-2R
-------------------------------------------------------------------------------
Project Title.......... WALLING:SATHER RES. Date........ 07/22/98
MICROPAS4 v4.50 File -17285B1' Wth-CTZ15S92 Program -FORM C -.2R
User#-MP0207.'User-M6dlin's,.Enterprises Run -REVISED CALCULATION I.
WATER HEATING SYSTEMS
----------------------
Number Tank
External
,. in Energy Size'
Insulation
.Tank Type Heater Type Distribution Type System Factor (gal)
-- -------------
R -value
-
------------- -------------- ------
1 Storage' Gas Recirc/TimeTemp 2 0.60 50
R-0
'SPECIAL FEATURES/REMARKS
----------------------- '
'
Tinted Glazing
Fixed and patio doors — Fleetwood - Norwood 3000 with„Low E
The values and materials used"`in-this compliance portfolio are
the minimum required to show compliance with Title. 24' Energgy
Conservation Standards. The owner may (at his, option)'install
better materials without additional compliance calculations.
The installing hvac contractor shall provide the required CF -6R
with the installed'hvac equipment model -numbers.
A Night setback thermostat is required to be`installed with the
HVAC system.
For additional information on the, proposed thermal mass locations
see the Mass Schedule and Notes in this compliance report.
The installed plumber, shall, provide the required CF` -6R listing
'
.the water heater model number(s)',and ;the certified plumbing
fixtures. • ... -
HVAC SIZING Page 1 HVAC
7 ----
Project Title.......... WALL'ING.SATHER•RES. Date....... 07/22/98
Project Address........: Lot 47 & 48 -,The Enclave******* ---------------------
La Quinta, Ca
Documentation Author... CATHERINE M. MADLIN. Buliding Permit
Madlin's Enterprises
P.O. Box 1443 Plan uneCk / Date
Palm Springs, CA 92262
619-324-1731 Fleid Cneck/Date
Climate Zone........... 15 1 -----------=---------
Compliance Method...... MICROPAS4,v4.50 for 1995 -Standards by Enercomp, Inc.
---------- ._________________________________
MICROPAS4 v4.50 File -17285B1 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP0207 User-Madlin's Enterprises Run -REVISED CALCULATION
-------------------- ---------'------------------------------------ ---------_----
GENERAL'INFORMATION
-------------------
Floor Area.. .4777 sf
Volume. . ....... 52547 cf
Front.Orientation. Front Facing 250 deg (W)
Sizing Location..... :. ... PALM DESERT
Latitude. . 33.7 degrees
Winter Outside Design 32 F
Winter Inside Design....... 70 F
Summer outside Design...... 112 F `•
Summer Inside Design.... 78 F
Summer Ran e...`. .: 34 F
Interior Shgading�Used ....... No '
Exterior Shading Used..,..... No
Overhang Shading Used...... No,
-Latent Load Fraction 0.20
HEATING AND COOLING LOAD SUMMARY
-------------------------------
Heating Cooling
Description (Btuh) (Btuh),
------------------------
Opaque Conduction and.Solar 23045 13220
Glazing Conduction........ .. 32485 29066
Glazing Solar.; ... .... n/a 47906
Infiltration ............ 27747 18363
Internal Gain.. .. ........ n/a- 3350
Ducts .......... 8328 11190
Sensible Load..... 91605 123094`
Latent Load. ....:.. n/a 24619
Minimum Total.Load 91605 147713
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements,. outdoor design temperatures; coil sizing, availability of
equipment, oversizing safety margin, etc.-, must also be considered. It is
sibilig
the HVAC designer's'respony to.co'nsider all factors when selecting
the HVAC equipment.
Manufacturer's,"Specifications
Simulated Total U -Value Summary
Report #1 930156
i Date: 12!10/93 Frame Option: None
Manufacturer: Fleetwood Aluminum Products Spacer Type (s): Dual -Seal Alum, Double Steel,
Model/Series
• Norwood 3000 Fixed Dual Seal (HM), Swiggle (#23)
Operator Type Fixed (or non -std shape) j
Note: For Glazing options, SS=Single-Strength d
_ - Frame Type: _-Aluminum OS=Double-Strenglh glass. For spacers,
_ SS=Single Seal and DS=Dual-Sea/.
�1
2
3
4
5
r'
6
j� 7
8
9
10
11
12
F
- - fnvvua rtrpresenrs ine -group Leader and has the highest U -value among the grouping of simulated
and Other Cen!er-of-glass options. IG un?groupings are allowed by N RC T/ 93001. 7nis report is the property of
WESTLeb and the client, and must not be reproduced, except in full• 1ti•ithout written a� prova1 from VVESTLah.
WESTLab
Initials:
DS_.764"Air DS 3116--_624•Air-3116"
with w/o dividers 1/4•-.562-A1r-3116• .69 .66
114' ..500-Alr -1 /4'
DS_ 764"Argon (80% fill typical)_DS 3116--•624•Argon-3116'
with w/o dividers' 1/4' - •56YArgon -'3116' .68 .64
1/4' - .500'Argon - 114'
DS LowE.200(sfc #2 typ)_764"Air DS
with w/o dividers
3116 LowE.200-.624•Air-311s-
1/4-LowE.200-.562'Air-3116':59
.55
1/4'LowE.200 - .500'Alr -1 /4'
DS LowE.200_.764"Argon_DS -
3116-LowE,200 - .624'Argon - 3116'
with w/o dividers
1/4-LowE.200 - .562'Argon - 3/16'
.57
.52
1/4'LowE.200 - .50'YAr on -1/4'
DS LowE.100_.764"Air DS
3116'Lo'"E'100-'624'Air-3116'
with w/o dividers
1/4'LowE.100-.562'Air-3116'
.57
.53
1/4'LowE.100 - .500'Air - 1/4'
DS LowE.100_.764"Argon_DS
3116•LowE•100-•624'Argon-3/16'
with w/O dividers
1/4'LowE.100 - .562'Argon - 3/16'
.54
.49
1 /4'LowE.100 - .500'Argon -1 /4'
.51
.46
DS .382"Air HI166• Air DS
w/o_dividers
DS_.382"Air HM66(sfc#3 typ)_Air DS
LowE.200(sfc#5 typ HM) w/o dividers
.48
.43
DS_.382"Air HM66_Air DS LowE.100
w/o dividers
.47
.42
DS_.382"Argon_HM66_Argon_DS LowE.100
w/o dividers
.45
.39
3116"_•312"Air HM66 Air 3116"
w/o dividers
.53
.48
3116" .312"Air HM66_Air 3116" LowE.200
w/o dividers
.51
.46
- - fnvvua rtrpresenrs ine -group Leader and has the highest U -value among the grouping of simulated
and Other Cen!er-of-glass options. IG un?groupings are allowed by N RC T/ 93001. 7nis report is the property of
WESTLeb and the client, and must not be reproduced, except in full• 1ti•ithout written a� prova1 from VVESTLah.
WESTLab
Initials:
I
2
.� 3
6
7
8
9
10
11
12
Report 9! .930121
Simulated Total U -Value Sunimary
Date: 8/24/93
Frame Option: None
Manufacturer. Fleetwood Aluminum Products Spacer Type(s)'
Dual -Seal Alum, Double Steel,
Norwood
f-
0 oodL
Model/Series: DOD Sliding Glass Door Dual Seal (HM), Swiggie (#23)
Operator Type: Double & Multiple Doors w/Frame
Note: For Glazing options, SS=SIngle-Strength &
Frame Type: Aluminum DS=Doubla-Strength glass. For spacers,
SS=Slnqla Seat and DS=DuaLSeaf.
#
S�_.764"Air DS
with w/o dividers 1/4"-.567AIr - 3/16'
.75
I /4''- SDTAJr,. 114 -
/;.7714
DS -.764"Argon (80% fill typical)DS
WIT- .624*Argon - 3116*
with w/o dividers
1/4-.567Ar2Dn -3116"
.74
.72
1/4'r .500'Argon 1/4"
DS LowE.200 .764"Air DS
316'L&wE200 -.624'Alr - 3116'
with w/o dividers
1/4'LaAE200 -.567Ak - 3116'
.63
1/4"LcwE=0 -.50TAIr -1 /4'
DS LowE.200 .764"Argon DS
3/16LvwE_-x -.624'Argon .311jr
with w/o dividers
1/4"L-YE200 -.56-TArgon - 3116'
I /4*Lgmf _W - SocrArgon -1/4'
.62
.60
DS LowE.1 00:.764"Air DS
311 OLewE.1 00 - .624'Alr - 3116'
with w/o -dividers
114-LowE. IDO-.56TAV-3/16-
.62
.61.
DS LowE.100 .764"Argon-DS
3116"LOWEI 00 -.624'Argon - 3116"
with w/o dividers
1/4'LowE.1 DO -.56TAr2on 3116"
1/4'LMSI 00 - .50TArpon-1/4'
DS_.382"Air_HM66Ai,rDS
_
w/o dividers
.53
DS LowE.200_.382"AlrDS
_HM66_Air
w/o dividers
.63
.51
DS LowE.100-.382"Air-HM66-Air-DS
w/o dividers
.52
.50
DS LowE.100-.382"Argon-HM66-Argon - DS
w/o dividers
.49
.47
3/.16"-.312"Air-HM,66-Air-.,3/16'I
w/o dividers.58
.56
3116" LowE.200-.312"Air-HM66-Air-3/16"
w/o dividers
.66
..54
rvvie; i ne simuierea prixfuct represents the 'Group Leader' and hes the hichest U -Value among the orouping of simulated
End Other Center -of -glass options. IG unit groupings are allowed by kFRC V 93001. This report is the property of
V -T S TL c- b E.9c' th e r_4 n t, End mus..' b e rep,-odjccd, exceip: i-, fu,',; K'i/70Ut vvr,'An approval from VVESTLeb.
.,WESTLab Initials
Afadlin's
en te> nses
Catheriw AS Madlin, Certified Energy Analyst . 619-322-5004 / 322-3410 (rax)
VV
V
Table Reprinted from C.E.C.. Residential Design Manual
Table 9-1: Site Built Fenestration Product U -Values
Framing Materials
Non -Metal, Except
Any Metal, Including" Fastener Hardware
Cladding and Door Thresholds
Single _ Double Single Double
Fixed 1.19 0.72 1.04 00.577 ('-1
Operable 1.32 0.93 0.99 0.55
Table 8-2: Manuraclured Fenestration Product Default LLValues
Framing Materials
Ther -mall
Any Metal Break' Non-bfe[02,3
Single Douhle4, Double4 Single Double4
Operable Windows 1.28 0.87 0.71 0.92 0.60
Fixed Windows 1.19 0.72 0.60 1.04 0.57
Patio Door 1.25 0.77 0.68 0.99 0.55
Skylights 1.26 (fg�> 0.70 0.91 0.55
Greenhouse Windows 2.26 1.40 1.12 1.94 1.06
1. The minimum design characteristics'to qualify as a Thermal Break Product are:
a. The material used as the thermal break must have,a thermal conductivity of not
more than 3.6 Btu-inch/hr/fit/OF, and;
b. The thermal break must produce a.gap of not less than 0.210', and;
c. All metal members of the product exposed to interior and exterior air must
incorporate a thermal break meeting the criteria in (a) and (b) above.
In addition, the product must be clearly labeled by the manufacturer that it qualifies as
a thermally broken product.in accordance with Commission requirements.
2. Non-metal products can include metal fasteners, hardware and door thresholds.
3. Add 0.04 to the listed U -value for any products that have. metal cladding in any
configuration.
4. For all dual glazed fenestration products adjust the listed U -values a5 follows:
a. Subtract 0.05 for spacers of 7/.16' or .rider.
b. Subtract 0.05 for Low -E glazing. .
c. Add 0.05 for -products "lith dividers between the panes if the spacer is less than
7/16" wide.
d. Add 0.05 to any product with Me divided lites (dividers throug` Lhe panes).
• f
• .
SC
}
• .
SC
GLASS TYPE
Clear `
SC
SC
-
Uncoated
Tinted
Reflect
Single
1.01
0.72-,
0.58
Double
0.90
° ` '6.57 `'
0.49
Triple ..
0.82
*1
•1
Double, Low -Emissivity
0.69
•1 , .
• 1
Double, Low Emissivity,
0.69
•1
! 1
Aigon Filled
*1 Must use clear. uncoated values in table B-12 or Manufacture data for these
window types
Based on 1/4 in glass
Source: Window 4.0