05-0305 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: �,
05-00000305
Property Address:
80775 VISTA BONITA TR
APN:
777-040-014- - -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
VERY LOW DENSITY RES
Application valuation:
27229
T414t 4 4 Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
LANCE ALA
51-800 VI
LA QUINTA
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
I
T®8 2007 1Pj
Contractor: I CITY O ILA Q� (�rjt\
Applicant: Architect or Engineer: SUNROSE- COR'P&P.44—INCECEPT
49950 JEFFERSON, #130-134
INDIO, CA 92201
(760)347-0089
Lic. No.: 533670
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that Iam licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: 13 License No.: 533670
Date:3- "o�7 Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
prnnarty rnthn hnilrir nr imprm,QQ thvrvvn, end v:ha aentreata fa? tha pd6;,Ct, ..;Il. u u—b—iui(-I 11 --ed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , 8.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued ISec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Date: 3/08/07
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are: '
Carrier EXEMPT Policy Number EXEMPT
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Co s II f with comply wit�those visions.
Date:3 �8 Applicant:
WARNING: FAILURE TO SECU E WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
i . rami peisuli upon whose benalt this app idati6i1 i3 made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and .state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned propert r inspec ' purposes.
Date 3"0"d7 Signature (Applicant or Agent):
Application Number . . . . . 05-00000305
Structure Information 337 SQ. FT. ,BEDROOM ADDITION
Construction Type . .
. . .. TYPE V - NON RATED
Occupancy Type . . .
. . " DWELLG/LODGING/CONG <=10
Flood Zone . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION 2001
CBC
# BEDROOMS
1.00
FLOOD ZONE NO
-------------------------------7--------------------------------------------
1ST FLOOR SQUARE FOOTAGE
337.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
271.50 Plan Check Fee
176.48
Issue Date . . . .
Valuation
27229
Expiration Date
10/11/05
Qty Unit Charge
Per
Extension
BASE FEE
252.00
3.00 6.5000
----------------------------------------------------------------------------
THOU BLDG 25,001-50,000
19.50
Permit . . .
ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee . . . .
26.80 Plan Check Fee
6.70
Issue Date
Valuation . . . .
0
Expiration Date
10/11/05.
Qty Unit Charge
Per
Extension
BASE FEE
15.00
337.00 .0350
----------------------------------------------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY
11.80
Permit . . .
MECHANICAL
Additional desc . .
Permit Fee . . .
24.00 Plan Check Fee
6.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date
10/11/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 •9.0000
----------------------------------------------------------------------------
EA MECH APPL REP/ALT/ADD
9.00
Permit . . .
PLUMBING
Additional desc .
_ Permit Fee. . . . .
36.00 Plan Check Fee
9.00
Issue Date . . . .
Valuation . . . .
0
LQPERMIT
Application Number . . . . . 05-00000305
Permit PLUMBING
Expiration Date'. 10/11/05
Qty Unit Charge Per
Extension
BASE FEE
15.00
3.00 6.0000 EA PLB FIXTURE
18.00
1.00. 3.0000 EA PLB WATER INST/ALT/REP
3.00
- -----------------------------------------------------------------------------
Special Notes and Comments
337 SQ. FT. BEDROOM ADDITION TO HOME
UNDER CONSTRUCTION. 1/31/05 7:20:19 AM
JJOHNSON
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE
17.65
STRONG MOTION (SMI)
- RES
2.72
Fee summary Charged Paid Credited
-----------------------------------------------
----------
Due
Permit Fee Total 358.30 .00
.00
358.30
Plan Check Total 198.18 .00
.00
198.18
Other Fee Total 20.37 .00
.00
20.37
Grand Total 576.85 .00
.00
576.85
LQPERMIT
Bin N
X
x
]�
X
A
JC
X
Project Address: S- p
A. P. Num . '
Leal Description: /--e%•
Contractor.
Address: I - 9 5-0
City, ST. Zip: 0
Telephone: TE;
State Lic.
Arch.. Engr.. Designer. '
Address:
Cite. ST. Zip:
Telephone: 416 7.
State Lic. M:
Name of Contact Person:
Telephone p of Contact Person:
a Submittal
ZPlan Sets 7=1
2- Structural Cala.
Truss Cala.
Energy Cala.
Flood plain pias
Grading plan
Subcontactor List
Grant Deed
H.O.A. Approval
IN HOUSE:.
Planning Approval
Pub. WkL Appr
School Fees ,
I
331
City of La Quinta
Building S Safety Division
0_51 0 3Z�6' P.O. Box 1504, 78-495 011e Tampico
V Quinta, U 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Owner's Name: e� .
• Address: <
�Zz0
City Lic. 0: Oe) 10,r
City* ST. Zip:
Telephone: 2 7SS - 90 �.
Project Description: 33-7
Re- J�I-ookK
o,-7
=^"'�-• - - =
A IJ cz-
Total Permit Fees
ConstructionTypo: -
YPe: S FD occupancy:
Project type (circle one): New Add'n Alter Repair Demo
'—
q.Ft.: 33
Pstimatcd
K Stones:
N Units:
7 0 C)
Value or Proiect:
10,0D0
APPLICANT: DO NOT WRITE BELOW THIS LINE
Recd
TRACKING _
PERNIFT FEES
Plan Check submitted
Item
Amount
Reviewed, ready for corrections
Plan Che -.k Deposit
Called Contact Person
Plan Chcrk Balance
Plans picked up
Construction
Plans resubmitted i If Q,g
111echasieal .
2" Review, ready for eorrectio issue
Electrical
Called Contact Person 3
Plumbing
Plass picked up
5.111.1.
Plats resubmitted
Grading
"Review' ad • co ectioo sue
Developer impact Fee
cowontact Perso tib QP.P.
Date of norm t iiww 11 _ _ _- .
A IJ cz-
Total Permit Fees
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE,
RECEIPT*
CHECK #•
INITIAIS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Residence_ s at_the La Qumta°Polo Date: January 31, 2005
Owner's Name: Lance Alacano Phone No.
Project Address: 41-860 Vista Bonita - ":'t La Quinta, CA
Project Description: Bedroom addition
APN: 772-280-014
Tract #:
Lot #'s:
Type of Development: Residential Rx, Commercial Industrial
Total Square Feet of Building Area: 337 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/deve:oper.
Dated: January 31, 2005 Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project
17620 65995 Approval
Note:
Number of Sq.Ft. 337
Amount per Sq.Ft. $ 2.68
Amount Collected $ 903.16
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Business Services
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Certificate issued by: Elvira Mattson, Office Technician Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day Feriod to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other aiplicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as Herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts o:o the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
'l�';C!»lyut�Gyi(Ieelce ;Cc[U17Ga?1c Orc(mplittnce ti)rm uAfle IC) C.lS(3.dve 1/16/03 T
y C�
O > ;
zzo
'0 90 -n
PoT
.im _
5C307 n
ALACANO RESIDENCE
La Quinta, CA
CLIMATE ZONE # 15
,BEDROOM, 4 added:
Mr. & Mrs. Alacano
Pekarek-Crandell, Inc.
HERITAGE ENERGY GROUP
December 1, 2004
Title 24 Energy Calculations
(949) 789-7221
Project Title.......... Custom Residence Date..i2/01/04 14:44:58
COMPLIANCE STATEMENT-
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply'with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
Name....
Company. Pekarek Crandell,Inc.
Address. Camino Capistrano #100
San Juan Captrno,CA 92675
Phone... 949 487-2320
License.
Signed..
ate
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
- Signed..
ate
DOCUMENTATION AUTHOR
Name.... Sam Maimone
Company. Heritage Energy Group
Address. 15375 Ba=anca Pkwy, Suite F-101
Irvine, C24 92618
Phone... 949-789-7221
Signed. . �/� ,.04
ate
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
Page 1
CF -1R
Project Title..........
Custom Residence
Date..12/01/04
14:44:58
Project Address........
Alacano Residence *******
---------------------
R-30
R-n/a R-30
Rancho La Quinta *v6.01*
(S)
FENESTRATION
Wind
Documentation Author...
Sam Maimone *******
41.0
Building Permit
Back
Heritage Energy Group
96.0
Wind
Back
(S)
15375 Barranca Pkwy, Suite F-101
Door
P an C ec
Date
96.0
Irvine, CA 92618
Right
(W)
224.0
Wind
949-789-7221
(W)
Field Check/
Date
Climate Zone.. ........
15
---------------------
Door
Front
Compliance Method......
MICROPAS6 v6.01 for 2001 Standards
by Enercomp,
Inc.
MICROPAS6 v6.01
File -24287M11 Wth-CTZ15S92 Program
-FORM CF-1R
Front
----------------User##_MP0940
User -Heritage Energy Group
---------------------------------
Run -
-----------------------
Front
GENERAL INFORMATION
Conditioned Floor Area..... 6645 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. 'Front Facing 0 deg (N)
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 18.1 % of floor area
Average Glazing U -factor... 0.38 Btu/hr-sf-F
Average Glazing SHGC....... 0.33
Average Ceiling Height..... 10.5 ft
BUILDING SHELL INSULATION
Component Frame Cavity Sheathing Total Assembly
Type Type R -value R -value R -value U -factor
------------
S1abEdge
S1abEdge
Wall
Roof Radiant
n/a
----
R-0
---------------
R-n/a
n/a
R-0
R-n/a
Wood
R-19
R-n/a R-19
Wood
R-30
R-n/a R-30
Back
(S)
FENESTRATION
U- Exterior
Factor SHGC Shading
------ ------ --------
F2=0.760
F2=0.510
0.065
0.035
Location/Comments
Over-
hang/
Fins Lccation/Comments
----- --------------------------
0.270 0.210 Standard Yes dual
0.350 0.350 Standard Yes dual
0.380 0.300 Standard None dual
0.530 0.510 Standard Yes dual
0.380 0.300 Standard Yes dual
0.270 0.210 Standard Yes dual
0.530 0.510 Standard Yes dual
0.380 0.300 Standard None dual
0.380 0.300 Standard Yes dual
0.270 0.210 Standard None dual
0.350 0.350 Standard Yes dual
0.380 0.300 Standard Yes dual
0.380 0.300 Standard None dual
0.350 0.350 Standard None dual
0.380 0.300 Standard None dual
0.380 0.300 Standard Yes dual
SLAB SURFACES
Area
Slab Type (sf)
---------------- ------
Standard Slab 2993
Standard Slab 1166
Standard Slab 1479
Standard Slab 1007
non metal fram low -e
wood frame low -e
wood frame low -e
pane
wood frame low -e
non metal fram low -e
pane
wood frame low -e
wood frame low -e
non metal fram low -e
wood frame low -e
wood frame low -e
wood frame low -e
wood frame low -e
wood frame low -e
wood frame low -e
Area
Orientation
----------------
(sf)
Door
Back
(S)
-----
240.0
Wind
Back
(S)
48.0
Wind
Back
(S)
41.0
Door
Back
(S)
96.0
Wind
Back
(S)
9.0
Door
Right
(W)
96.0
Door
Right
(W)
224.0
Wind
Right
(W)
58.0
Wind
Right
(W)
25.0
Door
Front
(N)
96.0
Wind
Front
(N)
24.0
Wind
Front
(N)
45.0
Wind
Front
(N)
56.0
Wind
Front
(N)
20.0
Wind
Left
(E)
94.5
Wind
Left
(E)
29.9
U- Exterior
Factor SHGC Shading
------ ------ --------
F2=0.760
F2=0.510
0.065
0.035
Location/Comments
Over-
hang/
Fins Lccation/Comments
----- --------------------------
0.270 0.210 Standard Yes dual
0.350 0.350 Standard Yes dual
0.380 0.300 Standard None dual
0.530 0.510 Standard Yes dual
0.380 0.300 Standard Yes dual
0.270 0.210 Standard Yes dual
0.530 0.510 Standard Yes dual
0.380 0.300 Standard None dual
0.380 0.300 Standard Yes dual
0.270 0.210 Standard None dual
0.350 0.350 Standard Yes dual
0.380 0.300 Standard Yes dual
0.380 0.300 Standard None dual
0.350 0.350 Standard None dual
0.380 0.300 Standard None dual
0.380 0.300 Standard Yes dual
SLAB SURFACES
Area
Slab Type (sf)
---------------- ------
Standard Slab 2993
Standard Slab 1166
Standard Slab 1479
Standard Slab 1007
non metal fram low -e
wood frame low -e
wood frame low -e
pane
wood frame low -e
non metal fram low -e
pane
wood frame low -e
wood frame low -e
non metal fram low -e
wood frame low -e
wood frame low -e
wood frame low -e
wood frame low -e
wood frame low -e
wood frame low -e
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... Custom -Residence Date..12/01/04 14:44:58
----------------
-------------------------------------
HVAC SYSTEMS -
Refrigerant Tested ACCA
Equipment Minimum Charge and Duct Duct Duct Manual Thermostat
---Type -Efficiency- Airflow Location R -value Leakage D Type
-------------------------------- ------ ---------
Furnace 0.800 AFUE n/a Attic
ACSplit 12.00 SEER No Attic
Living: Minimum Heating Load: 49,390 Btuh
Cooling Load: 44,297(Sensible),53,156(Total)
Masterbed: Minimum Heating Load: 16,025 Btuh
Cooling Load: 15,371(Sensible),18,446(Total)
Brs/bath: Minimum Heating Load: 21,564 Btuh
Cooling Load: 18,440(Sensible),22,129(Total)
R-4.2 No No Setback
R-4.2 No No Setback
Cabana/Casita: Minimum Heating Load: 19,643 Btuh
Cooling Load:-16,099(Sensible),19,319(Total)
Note: The loads shown are only one of the criteria affecting the selection of
HVAC equipment. Other relevant design factors such as air flow requirements,
outdoor design temperatures, coil sizing, availability of equipment, oversizing
safety margin, etc., must also be considered. It is the HVAC designer's
responsibility to consider all factors when selecting the HVAC equipment. That
individual is required to provide Form CF -6R, an Installation Certificate,
which must be posted at the building site prior to issuance of the occupancy
permit. The CF -6R is not required for permit submittal. It is intended to
insure installation of equipment that meets the efficiency requirements of the
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value --
------------------------------ -------------- ------ ----------
Large Gas Recirc/TimeTemp 1 n,,/a 100 R-12
Rheem Water Heater ## RHG PRO100-75 (or equal)
*All piping used to recirculate hot water must be insulated with R -4 -insulation
or equivalent. This includes any recirculating piping located in concrete
slabs or underground.
A timer must be permanently installed to regulate pump operation. Timer
setting must permit the pump to be cycled for at least eight hours per day.
An automatic thermostatic control must be installed to cycle the pump on and
off in response to the temperature of the water returning to the water heater
through the recirculation piping. Minimum differential or "Deadband" of the
control shall not be less than 20 degrees F.
WATER HEATING SYSTEMS DETAIL Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency Input Fraction R -value Light ----
--------------------------------------------------------------
Large 0.76 n/a 0.0318 R-0 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------
-----------------------
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
REMARKS
CERTIFICATE OF COMPLIANCE .RESIDENTIAL Page 3 CF -1R
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... Guest Suite Date..08/03/04 16:11:33
Project Address........ Alacano Residence ******* ---------------------
Rancho La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 BarrancaPkwy, Suite F-101 Plan Check Date
Irvine, CA 92618
949-789-7221 Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method ...... -MICROPAS6 x6.01 for 2001 Standards by Enercomp, Inc.
I MICROPAS6 v6.01 File -24287M21 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0940 User -Heritage Energy Group Run-
------------ ------------- ------ ----- -----------------
GENERAL
un-----------------------------------------------------------GENERAL INFORMATION
Conditioned Floor Area..... 544 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front.Orientation. Front Facing 180 deg (S)
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 27.3 % of floor area
Average Glazing U -factor... 0.31 Btu/hr-sf-F
Average Glazing SHGC....... 0.24
Average Ceiling Height..... 10 ft
BUILDING SHELL INSULATION
Component Frame Cavity Sheathing Total Assembly
Type Type R -value R -value R -value U -factor Location/Comments
------------------------------------------------- ------------------------
S1abEdge n/a R-0 R-n/a F2=0.760
S1abEdge n/a R-0 R-n/a F2=0.510
Wall Wood R-19 R-n/a R-19 0.065
RoofRadiant Wood R-30 R-n/a R-30 0.035
FENESTRATION
Over -
Area
U-
Exterior
hang/
Orientation
-------- -----
(sf)
------ ------
Factor
--------
SHGC
Shading
Fins
Location/Comments
--------
Wind
Back
(N)
22.5
0.380
0.300
----- --------------------------
Standard
Yes
dual
wood frame
low -e
Door
Front
(S)
96.0
0.270
0.210
Standard
Yes
dual
non metal
fram low -e
Wind
Front
(S)
10.0
0.380
0.300
Standard
Yes
dual
wood frame
low -e
Wind
Left
(W)
20.0
0.380
0.300
Standard
None
dual
wood frame
low -e
SLAB
-------------
SURFACES
Area
Slab Type
----------------
(sf)
Standard
Slab
------
544
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... Guest Suite Date..08/03/04 16:11:33
HVAC SYSTEMS
Refrigerant Tested ACOA
Equipment Minimum Charge and Duct Duct Duct Manual Thermostat-
--- -
Type Efficiency- Airflow Location R -value Leakage D Type
----------------------------- ------ ------
Furnace 0.800 AFUE n/a Attic R-4.2 No No Setback
ACSplit 12.00 SEER No Attic R-4.2 No No Setback
Minimum Heating Load: 11,578 Btuh
Cooling Load: 11,466(Sensible),13,759(Total)
Note: The loads shown are only one of the criteria affecting the selection of
HVAC equipment. Other relevant design factors such as air flow requirements,
outdoor design temperatures, coil sizing, availability of equipment, oversizing
safety margin, etc., must also be considered. It is the HVAC designer's
responsibility to consider all factors when selecting the HVAC equipment. That
individual is required to provide Form CF -6R, an Installation Certificate,
which must be posted at the building site prior to issuance of the occupancy
permit. The CF -6R is not required for permit submittal. It is intended to
insure installation of equipment that meets the efficiency requirements of the
compliance documentation.
WATER HEATING SYSTEMS
As per UPC chapter 5:
The minimum capacity for water heaters shall be in accordance with the first
hour rating listed in Table 5-1 below.
-----------------------------------------------------= ________________
Number of Bathrooms 1 to 1.5 2 to 2.5 3 to 3.5
------------------------- ----------- --------------_ _______________
Number of Bedrooms 1=1=2= 3 2 3 4 5 3 4 5 6
------------ --_ ___
1st. Hour Rating, Gallons 42 54 54 54 67 67 80 67 80 80 80
SPECIAL FEATURES AND MODELING ASSUMP^IONS------------------
-----------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specificat-ons, and ***
*** verified during plan check and field inspect=on. ***
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
REMARKS
Number
Tank
External
Tank Type Heater Type Distribution Type
----------------------------------------
in
System
Energy Size
Factor (gal)
Insulation
R -value --
------
Storage Gas Standard
--------
1
------ ----------
0.60 50
R- n/a
RHEEM MODEL ## RHG PRO50-40 (OR EQUAL)
FIRST.HOUR RATING, GALLONS (83)
As per UPC chapter 5:
The minimum capacity for water heaters shall be in accordance with the first
hour rating listed in Table 5-1 below.
-----------------------------------------------------= ________________
Number of Bathrooms 1 to 1.5 2 to 2.5 3 to 3.5
------------------------- ----------- --------------_ _______________
Number of Bedrooms 1=1=2= 3 2 3 4 5 3 4 5 6
------------ --_ ___
1st. Hour Rating, Gallons 42 54 54 54 67 67 80 67 80 80 80
SPECIAL FEATURES AND MODELING ASSUMP^IONS------------------
-----------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specificat-ons, and ***
*** verified during plan check and field inspect=on. ***
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
REMARKS
COMPUTER METHOD SUMMARY
Standard
Page 1
C -2R
Project Title..........
Custom Residence
Date..12/01/04
14:44:58
Project Address........
Alacano Residence *******
---------------------.
---------- -
-0.59 =
= Space Cooling..........
Rancho La Quinta *v6.01*
33.04
1.34 =
Documentation Author...
Sam Maimone *******
Building Permit
0.88 =
Heritage Energy Group
41.79
40.16
1.63 =
15375 Barranca Pkwy, Suite F-101
Plan Check
Date
Type
-----------
Irvine, CA 92618
(sf)
--------
Credit
---------
Climate Zone..... .....
949-789-7221
15
Field Check/
---------------------
Date
Compliance Method......
MICROPAS6 v6.01 for 2001 Standards
by Enercomp,
Inc.
MICROPAS6 v6.01' File -24287M11 Wth-CTZ15S92 Program
-FORM C -2R
0.18
User#-MP0940 User -Heritage Energy Group
----------------------- --------------- ------- ------
Run -
-----------------------
2.0
-----------------
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
----------
Design
Margin =
= Space Heating..........
3.12
----------
3.71
---------- -
-0.59 =
= Space Cooling..........
34.38
33.04
1.34 =
= Water Heating..........
4.29
3.41
0.88 =
_ Total
41.79
40.16
1.63 =
_ *** Building complies
with Computer
Performance
Zone Type
1
Residence
2
Residence
3
Residence
GENERAL INFORMATION
Conditioned Floor Area..... 6645 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 0 deg (N)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
4
69443 cf
6645 sf
18.1 % of floor area
0.38 Btu/hr-sf-F
0.33
10.5 ft
BUILDING
ZONE INFORMATION
Floor
-------------------------
# of
Vent
Vent
Air
Area
Volume
Dwell
Cond-
Thermostat
Height
Area
Leakage
(sf)
-----
(cf)
-------
Units
-----
itioned
-------
Type
-----------
(ft)
-----
(sf)
--------
Credit
---------
2993
32923
0.47
Yes
Setback
2.0
Standard
No
1166
11660
0.18
Yes
Setback
2.0
Standard
No
1479
14790
0.19
Yes
Setback
2.0
Standard
No
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... Custom Residence Date..12/01/04 14:44:58
BUILDING ZONE INFORMATION
--------------------------
.Floor # of Vent Vent Air
Area Volume Dwell Cond- Thermostat Height Area Leakage
Zone.Type (sf) (cf) Units itioned Type (ft) (sf) Credit
-------------- ------------ ----------------------- ----- -------- ---------
4
Residence 1007 10070 0.16 Yes Setback 2.0 Standard No
OPAQUE SURFACES
---------------
Area U- Insul Act Solar Form 3 Location/
Surface (sf) factor R-val Azm Tilt Gains Reference Comments
--------------- ------ ----- ----- --- ---- ----------------- ----------------
1
6 Wall 608 0.065 19 180 90 Yes None
10 Wall 243 0.065 19 270 90 Yes None
14 Wall 530 0.065 19 0 90 Yes None
17 Wall 659 0.065 19 90 90 Yes None
20 Wall 250 0.065 19 0 90 No None
21 RoofRadiant 2993 0.035 30 n/a 0 Yes None
2
7 Wall 144 0.065 19 180 90 Yes None
11 Wall 462 0.065 19 270 90 Yes None
22 RoofRadiant 1166 0.035 30 n/a 0 Yes None
3
8 Wall 231 0.065 19 180 90 Yes None
12 Wall 236 0.065 19 270 90 Yes None
15 Wall 474 0.065 19 0 90 Yes None
18 Wall 477 0.065 19 90 90 Yes None
23 RoofRadiant 1479 0.035 30 n/a 0 Yes None
4
9 Wall 435 0.065 19 180 90 Yes None
13 Wall 148 0.065 19 270 90 Yes None
16 Wall 415 0.065 19 0 90 Yes None
19 Wall 247 0.065 19 90 90 Yes None
24 RoofRadiant 1007 0.0.35 30 n/a 0 Yes None
PERIMETER LOSSES
----------------
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1
1 SlabEdge 249 0.760 R-0 No
5 SlabEdge 25 0.510 R-0 No
2
2 SlabEdge 76 0.760 R-0 No
3
3 SlabEdge 132 0.760 R-0 No
4
4 SlabEdge 146 0.760 R-0 No
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... Custom Residence Date..12/01/04 14:44:58
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ --------=---------------
1
1 Door Back (S) 192.0 0.270 0.210 180 90 Standard dual non metal fram low -
2 Wind Back (S) 48.0 0.350 0.350 180 90 Standard dual wood frame low -e
3 Door Back (S) 48.0 0.270 0.210 180 90 Standard dual non metal fram low -
4 Wind Back (S) 6.0 0.380 0.300 180 90 Standard dual wood frame low -e
9 Door Right (W) 96.0 0.270 0.210 270 90 Standard dual non metal fram low -
10 Door Right (W) 112.0 0.530 0.510 270 90 Standard dual pane
17 Door Front (N) 96.0 0.270 0.210 0 90 Standard -dual non metal fram low -
18 Wind Front (N) 24.0 0.350 0.350 0 90 Standard -dual wood frame low -e
19 Wind Front (N) 10.0 0.380 0.300 0 90 Standard dual wood frame low -e
25 Wind Left -(E) 37.5 0.380 0.300 90 90 Standard dual wood frame low -e
26 Wind Left (E) 4.5 0.380 0.300 90 90 Standard dual wood frame low -e
27 Wind Left (E) 5.4 0.380 0.300 90 90 Standard dual wood frame low -e
28 Wind Left (E) 20.0 0.380 0.300 90 90 Standard dual wood frame low -e
2
5 Door Back (S) 96.0 0.530 0.510 180 90 Standard dual pane
11 Wind Right (W) 13.5 0.380 0.300 270 90 Standard dual wood frame low -e
12 Wind Right (W) 25.0 0.380 0.300 270 90 Standard dual wood frame low -e
13 Wind Right (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e
3
6 Wind Back (S) 9.0 0.380 0.300 180 90 Standard dual wood frame low -e
14 Wind Right (W) 4.5 0.380 0.300 270 90 Standard dual wood frame low -e
15 Wind Right (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e
20 Wind Front (N) 20.0 0.380 0.300 0 90 Standard dual wood frame low -e
21 Wind Front (N) 36.0 0.380 0.300 0 90 Standard dual wood frame low -e
29 Wind Left (E) 9.0 0.380 0.300 90 90 Standard dual wood frame low -e
30 Wind Left (E) 4.5 0.380 0.300 90 90 Standard dual wood frame low -e
31 Wind Left (E) 30.0 0.380 0.300 90 90 Standard dual wood frame low -e
4
7 Wind Back (S) 20.0 0.380 0.300 180 90 Standard dual wood frame low -e
8 Wind Back (S) 15.0 0.380 0.300 180 90 Standard dual wood frame low -e
16 Door Right (W) 112.0 0.530 0.510 270 90 Standard dual pane
22 Wind Front (N) 20.0 0.350 0.350 0 90 Standard dual wood frame low -e
23 Wind Front (N) 20.0 0.380 0.300 0 90 Standard dual wood frame low -e
24 Wind Front (N) 15.0 0.380 0.300 0 90 Standard dual wood frame low -e
32 Wind Left (E) 13.5 0.380 0.300 90 90 Standard dual wood frame low -e
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area Left Rght
Surface -(sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----------- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---------
1
1 Door 192.0 n/a 8 16 3 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 48.0 n/a 2 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
3 Door 48.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
9 Door 96.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
10 Door 112.0 n/a 8 12 2 n/a n/a n/a n/a n/a n/a n/a n/a
18 Window 24.0 n/a 2 2 1 n/a n/a n/a n/a n/a n/a n/a n/a
19 Window 10.0 n/a 5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a
26 Window 4.5 n/a 3 2 1 n/a n/a n/a n/a n/a n/a n/a n/a
27 Window 5.4 n/a 1.5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a
28 Window 20.0 n/a 5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a
2
COMPUTER METHOD SUMMARY Page 4 C -2R
Project Title.......... Custom Residence Date..12/01/04 14:44:58
OVERHANGS AND SIDE FINS
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
1
Standard Slab 2993
2
Standard Slab 1166
3
Standard Slab 1479
4
Standard Slab 1007
---Window--
------Overhang-----
---Left Fin---.
---Right
Fin --
Area
Tested
ACCA
Left
Rght
Charge and Duct
Duct
Duct
Manual
Duct
Type
-------------
Surface
-(sf)
Wdth
-----
Hgth
-----
Dpth
----
Hght
----
Ext
----
Ext
----
Ext
----
Dpth
Hght
Ext
Dpth
Hght
5
Door
96.0
n/a
8
12
2
n/a
n/a
n/a
----
n/a
----
n/a
----
n/a
----
n/a
----
n/a
12
Window
25.0
n/a
5
2
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
3
0.743
ACSplit
12.00
SEER
No Attic
R-4.2
No
No
0.637
3
6
Window
9.0
n/a
3
12
2
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4
No
No
0.637
4
Furnace
0.800
AFUE
16
Door
112.0
n/a
6
12
2
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
23
Window
20.0
n/a
3
2
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
24
Window
15.0
n/a
5
2
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
1
Standard Slab 2993
2
Standard Slab 1166
3
Standard Slab 1479
4
Standard Slab 1007
HVAC SYSTEMS
------------
Refrigerant
Tested
ACCA
System
Minimum
Charge and Duct
Duct
Duct
Manual
Duct
Type
-------------
Efficiency
-----------
Airflow Location
R -value
Leakage
D
Eff
1
--------------------
----------------
--------
----
Furnace
0.800
AFUE
n/a Attic
R-4.2
No
No
0.743
ACSplit
12.00
SEER
No Attic
R-4..2
No
No
0.637
2
Furnace
0.800
AFUE
n/a Attic
R-4.2
No
No
0.743
ACSplit
12.00
SEER
No Attic
R-4.2
No
No
0.637
3
Furnace
0.800
AFUE
n/a Attic
R-4.2
No
No
0.743
ACSplit
12.00
SEER
No Attic
R-4.2
No
No
0.637
4
Furnace
0.800
AFUE
n/a Attic
R=4.2
No
No
0.743
ACSplit
12.00
SEER
No Attic
R-4..2
No
No
0.637
WATER HEATING SYSTEMS
---------------------
Number
Tank
External
in Energy
Size
Insulation
Tank Type
------------
Heater
-----------
Type
Distribution Type
-------------------
System Factor
(gal)
R -value
1 Large
Gas
Recirc/TimeTemp
--------------
1 n/a
------
100
----------
R-12
COMPUTER METHOD SUMMARY Page 5 C -2R
Project Title.......... Custom Residence Date..12/01/04 14:44:58
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency ---Input -Fraction----R_value ' Light
------------ -- ----------------------
1 Large 0.76 n/a 0.0318 R-0 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented cn the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses,.rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
This building incorporates non-standard Water Heating System
REMARKS
COMPUTER METHOD SUMMARY
Standard
Page 1
C -2R
Project Title. .
Project Address........
Guest Suite
Date..08/03/04
16:11:33
Space Heating..........
Alacano Residence
*******_____________________.
-----------
-0.23 -
= Space Cooling..........
Rancho La Quinta
*v6.01*
4.09 =
= Water Heating..........
Documentation Author...
Sam Maimone
*******
Bui ing Permit
97.05
Heritage Energy Group
-------- -
9.38 =
_ *** Building complies
with Computer Performance
15375 Barranca Pkwy,
Suite F-101
Plan C ec
Date
Irvine, CA 92618
Climate Zone.. ........
949-789-7221
15
Fie C ec
Date
Compliance Method......
MICROPAS6 v6.01 for
2001 Standards by Enercomp,
Inc.
I MICROPAS6 v6.01 File -24287M21 Wth-CTZ15S92 Prcgram-FORM C -2R
User##_MP0940 User -Heritage
---------------- --------------------------------------------------------
Energy Group Run-
I
------------------
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
------------------------
Design
----------
Design
Margin =
Space Heating..........
3.67
----------
3.90
-----------
-0.23 -
= Space Cooling..........
58.44
54.35
4.09 =
= Water Heating..........
34.94
29.42
5.52 -
= Total
97.05
--------
87.67
-------- -
9.38 =
_ *** Building complies
with Computer Performance
GENERAL INFORMATION
Conditioned Floor Area..... 544 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front orientation. Front Facing 180 deg (S)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Zone Type
--------------
1
Residence.
Slab On Grad --
1
5440 cf
544 sf
27.3 % of floor area
0.31 Btu/hr-sf-F
0.24
10 ft
BUILDING ZONE INFORMATION
-------------------------
Floor ## of Vent Vent Air
Area Volume Dwell. Cond- Thermostat Height Area Leakage
(sf) (cf) Units itioned Type (ft) (sf) Credit
------------ ----------------------- ----- -------- ---------
544 5440 1.00 Yes Setback 2.0 Standard No
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title....:..... Guest Suite' Date..08/03/04 16:11:33
OPAQUE SURFACES
Surface
-----------
1
1 SlabEdge
2 SlabEdge
PERIMETER LOSSES
----------------
Length F2 Insul Solar
(ft) Factor R-val Gains Location/Comments
--------------- ----- ----------------------
84 0.760 R-0 No
17 0.510 R-0 No
FENESTRATION SURFACES
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
----- ----- --- ------------ ------------------------
1
1 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e
2 Wind Back (N) 4.5 0.380 0.300 0 90 Standard dual wood frame low -e
3 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e
4 Door Front (S) 96.0 0.270 0.210 180 90 Standard dual non metal fram low -
5 Wind Front (S) 10.0 0.380 0.300 180 90 Standard dual wood frame low -e
6 Wind Left (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
--- ---- ---- ---- ---- ---- ---- ---- ---- ----
1 ----
1 Window 9.0 n/a 8 16 3 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 4.5 n/a 2 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
3 Window 9.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
4 Door 96.0 n/a 8 12 2 n/a n/a n/a n/a n/a n/a n/a n/a
5 Window 10.0 n/a 3 12 2 n/a n/a n/a n/a n/a n/a n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
1
Standard Slab 544
Area
U-
Insul
Act
Solar
Form 3 Location/
Surface
(sf)
factor
-----
R-val
-----
Azm
---
Tilt
Gains
Reference Comments
1
----
-----
------------ ----------------
3
Wall
328
0.065
19
0
90
Yes
None
4
Wall
224
0.065
19
180
90
Yes
None
5
Wall
140
0.065
19
270
90
Yes
None
6
Wall
170
0:065
19
180
90
No
None
7
Roof Radiant
544
0.035
30
n/a
0
Yes
None
Surface
-----------
1
1 SlabEdge
2 SlabEdge
PERIMETER LOSSES
----------------
Length F2 Insul Solar
(ft) Factor R-val Gains Location/Comments
--------------- ----- ----------------------
84 0.760 R-0 No
17 0.510 R-0 No
FENESTRATION SURFACES
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
----- ----- --- ------------ ------------------------
1
1 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e
2 Wind Back (N) 4.5 0.380 0.300 0 90 Standard dual wood frame low -e
3 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e
4 Door Front (S) 96.0 0.270 0.210 180 90 Standard dual non metal fram low -
5 Wind Front (S) 10.0 0.380 0.300 180 90 Standard dual wood frame low -e
6 Wind Left (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
--- ---- ---- ---- ---- ---- ---- ---- ---- ----
1 ----
1 Window 9.0 n/a 8 16 3 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 4.5 n/a 2 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
3 Window 9.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a
4 Door 96.0 n/a 8 12 2 n/a n/a n/a n/a n/a n/a n/a n/a
5 Window 10.0 n/a 3 12 2 n/a n/a n/a n/a n/a n/a n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
1
Standard Slab 544
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... Guest Suite Date..08/03/04 16:11:33
HVAC SYSTEMS
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
-- ----------------- -------------- ------ ----------
1 Storage Gas Standard 1 0.60 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented cn the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
REMARKS
Refrigerant
Tested
ACOA
System
Minimum
Charge and Duct
Duct
Duct
Manual
Duct
---Type------
Efficiency
----
Airflow Location
--------------------
R -value
Leakage
D
Eff
1
-------
---------
--------
----
Furnace
0.800 AFUE
n/a Attic
R-4.2
No
No
0.743
ACSplit
12.00 SEER
No Attic
R-4.2
No
No
0.637
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
-- ----------------- -------------- ------ ----------
1 Storage Gas Standard 1 0.60 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented cn the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
REMARKS