Loading...
05-0305 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: �, 05-00000305 Property Address: 80775 VISTA BONITA TR APN: 777-040-014- - - Application description: ADDITION - RESIDENTIAL Property Zoning: VERY LOW DENSITY RES Application valuation: 27229 T414t 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: LANCE ALA 51-800 VI LA QUINTA VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 I T®8 2007 1Pj Contractor: I CITY O ILA Q� (�rjt\ Applicant: Architect or Engineer: SUNROSE- COR'P&P.44—INCECEPT 49950 JEFFERSON, #130-134 INDIO, CA 92201 (760)347-0089 Lic. No.: 533670 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that Iam licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: 13 License No.: 533670 Date:3- "o�7 Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of prnnarty rnthn hnilrir nr imprm,QQ thvrvvn, end v:ha aentreata fa? tha pd6;,Ct, ..;Il. u u—b—iui(-I 11 --ed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , 8.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued ISec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Date: 3/08/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: ' Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Co s II f with comply wit�those visions. Date:3 �8 Applicant: WARNING: FAILURE TO SECU E WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. i . rami peisuli upon whose benalt this app idati6i1 i3 made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and .state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned propert r inspec ' purposes. Date 3"0"d7 Signature (Applicant or Agent): Application Number . . . . . 05-00000305 Structure Information 337 SQ. FT. ,BEDROOM ADDITION Construction Type . . . . .. TYPE V - NON RATED Occupancy Type . . . . . " DWELLG/LODGING/CONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 1.00 FLOOD ZONE NO -------------------------------7-------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 337.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 271.50 Plan Check Fee 176.48 Issue Date . . . . Valuation 27229 Expiration Date 10/11/05 Qty Unit Charge Per Extension BASE FEE 252.00 3.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 19.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 26.80 Plan Check Fee 6.70 Issue Date Valuation . . . . 0 Expiration Date 10/11/05. Qty Unit Charge Per Extension BASE FEE 15.00 337.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 11.80 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . 24.00 Plan Check Fee 6.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/11/05 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 •9.0000 ---------------------------------------------------------------------------- EA MECH APPL REP/ALT/ADD 9.00 Permit . . . PLUMBING Additional desc . _ Permit Fee. . . . . 36.00 Plan Check Fee 9.00 Issue Date . . . . Valuation . . . . 0 LQPERMIT Application Number . . . . . 05-00000305 Permit PLUMBING Expiration Date'. 10/11/05 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00. 3.0000 EA PLB WATER INST/ALT/REP 3.00 - ----------------------------------------------------------------------------- Special Notes and Comments 337 SQ. FT. BEDROOM ADDITION TO HOME UNDER CONSTRUCTION. 1/31/05 7:20:19 AM JJOHNSON ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 17.65 STRONG MOTION (SMI) - RES 2.72 Fee summary Charged Paid Credited ----------------------------------------------- ---------- Due Permit Fee Total 358.30 .00 .00 358.30 Plan Check Total 198.18 .00 .00 198.18 Other Fee Total 20.37 .00 .00 20.37 Grand Total 576.85 .00 .00 576.85 LQPERMIT Bin N X x ]� X A JC X Project Address: S- p A. P. Num . ' Leal Description: /--e%• Contractor. Address: I - 9 5-0 City, ST. Zip: 0 Telephone: TE; State Lic. Arch.. Engr.. Designer. ' Address: Cite. ST. Zip: Telephone: 416 7. State Lic. M: Name of Contact Person: Telephone p of Contact Person: a Submittal ZPlan Sets 7=1 2- Structural Cala. Truss Cala. Energy Cala. Flood plain pias Grading plan Subcontactor List Grant Deed H.O.A. Approval IN HOUSE:. Planning Approval Pub. WkL Appr School Fees , I 331 City of La Quinta Building S Safety Division 0_51 0 3Z�6' P.O. Box 1504, 78-495 011e Tampico V Quinta, U 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Owner's Name: e� . • Address: < �Zz0 City Lic. 0: Oe) 10,r City* ST. Zip: Telephone: 2 7SS - 90 �. Project Description: 33-7 Re- J�I-ookK o,-7 =^"'�-• - - = A IJ cz- Total Permit Fees ConstructionTypo: - YPe: S FD occupancy: Project type (circle one): New Add'n Alter Repair Demo '— q.Ft.: 33 Pstimatcd K Stones: N Units: 7 0 C) Value or Proiect: 10,0D0 APPLICANT: DO NOT WRITE BELOW THIS LINE Recd TRACKING _ PERNIFT FEES Plan Check submitted Item Amount Reviewed, ready for corrections Plan Che -.k Deposit Called Contact Person Plan Chcrk Balance Plans picked up Construction Plans resubmitted i If Q,g 111echasieal . 2" Review, ready for eorrectio issue Electrical Called Contact Person 3 Plumbing Plass picked up 5.111.1. Plats resubmitted Grading "Review' ad • co ectioo sue Developer impact Fee cowontact Perso tib QP.P. Date of norm t iiww 11 _ _ _- . A IJ cz- Total Permit Fees Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE, RECEIPT* CHECK #• INITIAIS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence_ s at_the La Qumta°Polo Date: January 31, 2005 Owner's Name: Lance Alacano Phone No. Project Address: 41-860 Vista Bonita - ":'t La Quinta, CA Project Description: Bedroom addition APN: 772-280-014 Tract #: Lot #'s: Type of Development: Residential Rx, Commercial Industrial Total Square Feet of Building Area: 337 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/deve:oper. Dated: January 31, 2005 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Note: Number of Sq.Ft. 337 Amount per Sq.Ft. $ 2.68 Amount Collected $ 903.16 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day Feriod to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other aiplicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as Herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts o:o the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. 'l�';C!»lyut�Gyi(Ieelce ;Cc[U17Ga?1c Orc(mplittnce ti)rm uAfle IC) C.lS(3.dve 1/16/03 T y C� O > ; zzo '0 90 -n PoT .im _ 5C307 n ALACANO RESIDENCE La Quinta, CA CLIMATE ZONE # 15 ,BEDROOM, 4 added: Mr. & Mrs. Alacano Pekarek-Crandell, Inc. HERITAGE ENERGY GROUP December 1, 2004 Title 24 Energy Calculations (949) 789-7221 Project Title.......... Custom Residence Date..i2/01/04 14:44:58 COMPLIANCE STATEMENT- -------------------- This certificate of compliance lists the building features and performance specifications needed to comply'with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... Company. Pekarek Crandell,Inc. Address. Camino Capistrano #100 San Juan Captrno,CA 92675 Phone... 949 487-2320 License. Signed.. ate ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... - Signed.. ate DOCUMENTATION AUTHOR Name.... Sam Maimone Company. Heritage Energy Group Address. 15375 Ba=anca Pkwy, Suite F-101 Irvine, C24 92618 Phone... 949-789-7221 Signed. . �/� ,.04 ate CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Custom Residence Date..12/01/04 14:44:58 Project Address........ Alacano Residence ******* --------------------- R-30 R-n/a R-30 Rancho La Quinta *v6.01* (S) FENESTRATION Wind Documentation Author... Sam Maimone ******* 41.0 Building Permit Back Heritage Energy Group 96.0 Wind Back (S) 15375 Barranca Pkwy, Suite F-101 Door P an C ec Date 96.0 Irvine, CA 92618 Right (W) 224.0 Wind 949-789-7221 (W) Field Check/ Date Climate Zone.. ........ 15 --------------------- Door Front Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File -24287M11 Wth-CTZ15S92 Program -FORM CF-1R Front ----------------User##_MP0940 User -Heritage Energy Group --------------------------------- Run - ----------------------- Front GENERAL INFORMATION Conditioned Floor Area..... 6645 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. 'Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 18.1 % of floor area Average Glazing U -factor... 0.38 Btu/hr-sf-F Average Glazing SHGC....... 0.33 Average Ceiling Height..... 10.5 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R -value R -value R -value U -factor ------------ S1abEdge S1abEdge Wall Roof Radiant n/a ---- R-0 --------------- R-n/a n/a R-0 R-n/a Wood R-19 R-n/a R-19 Wood R-30 R-n/a R-30 Back (S) FENESTRATION U- Exterior Factor SHGC Shading ------ ------ -------- F2=0.760 F2=0.510 0.065 0.035 Location/Comments Over- hang/ Fins Lccation/Comments ----- -------------------------- 0.270 0.210 Standard Yes dual 0.350 0.350 Standard Yes dual 0.380 0.300 Standard None dual 0.530 0.510 Standard Yes dual 0.380 0.300 Standard Yes dual 0.270 0.210 Standard Yes dual 0.530 0.510 Standard Yes dual 0.380 0.300 Standard None dual 0.380 0.300 Standard Yes dual 0.270 0.210 Standard None dual 0.350 0.350 Standard Yes dual 0.380 0.300 Standard Yes dual 0.380 0.300 Standard None dual 0.350 0.350 Standard None dual 0.380 0.300 Standard None dual 0.380 0.300 Standard Yes dual SLAB SURFACES Area Slab Type (sf) ---------------- ------ Standard Slab 2993 Standard Slab 1166 Standard Slab 1479 Standard Slab 1007 non metal fram low -e wood frame low -e wood frame low -e pane wood frame low -e non metal fram low -e pane wood frame low -e wood frame low -e non metal fram low -e wood frame low -e wood frame low -e wood frame low -e wood frame low -e wood frame low -e wood frame low -e Area Orientation ---------------- (sf) Door Back (S) ----- 240.0 Wind Back (S) 48.0 Wind Back (S) 41.0 Door Back (S) 96.0 Wind Back (S) 9.0 Door Right (W) 96.0 Door Right (W) 224.0 Wind Right (W) 58.0 Wind Right (W) 25.0 Door Front (N) 96.0 Wind Front (N) 24.0 Wind Front (N) 45.0 Wind Front (N) 56.0 Wind Front (N) 20.0 Wind Left (E) 94.5 Wind Left (E) 29.9 U- Exterior Factor SHGC Shading ------ ------ -------- F2=0.760 F2=0.510 0.065 0.035 Location/Comments Over- hang/ Fins Lccation/Comments ----- -------------------------- 0.270 0.210 Standard Yes dual 0.350 0.350 Standard Yes dual 0.380 0.300 Standard None dual 0.530 0.510 Standard Yes dual 0.380 0.300 Standard Yes dual 0.270 0.210 Standard Yes dual 0.530 0.510 Standard Yes dual 0.380 0.300 Standard None dual 0.380 0.300 Standard Yes dual 0.270 0.210 Standard None dual 0.350 0.350 Standard Yes dual 0.380 0.300 Standard Yes dual 0.380 0.300 Standard None dual 0.350 0.350 Standard None dual 0.380 0.300 Standard None dual 0.380 0.300 Standard Yes dual SLAB SURFACES Area Slab Type (sf) ---------------- ------ Standard Slab 2993 Standard Slab 1166 Standard Slab 1479 Standard Slab 1007 non metal fram low -e wood frame low -e wood frame low -e pane wood frame low -e non metal fram low -e pane wood frame low -e wood frame low -e non metal fram low -e wood frame low -e wood frame low -e wood frame low -e wood frame low -e wood frame low -e wood frame low -e CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Custom -Residence Date..12/01/04 14:44:58 ---------------- ------------------------------------- HVAC SYSTEMS - Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat ---Type -Efficiency- Airflow Location R -value Leakage D Type -------------------------------- ------ --------- Furnace 0.800 AFUE n/a Attic ACSplit 12.00 SEER No Attic Living: Minimum Heating Load: 49,390 Btuh Cooling Load: 44,297(Sensible),53,156(Total) Masterbed: Minimum Heating Load: 16,025 Btuh Cooling Load: 15,371(Sensible),18,446(Total) Brs/bath: Minimum Heating Load: 21,564 Btuh Cooling Load: 18,440(Sensible),22,129(Total) R-4.2 No No Setback R-4.2 No No Setback Cabana/Casita: Minimum Heating Load: 19,643 Btuh Cooling Load:-16,099(Sensible),19,319(Total) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. That individual is required to provide Form CF -6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF -6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value -- ------------------------------ -------------- ------ ---------- Large Gas Recirc/TimeTemp 1 n,,/a 100 R-12 Rheem Water Heater ## RHG PRO100-75 (or equal) *All piping used to recirculate hot water must be insulated with R -4 -insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. A timer must be permanently installed to regulate pump operation. Timer setting must permit the pump to be cycled for at least eight hours per day. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light ---- -------------------------------------------------------------- Large 0.76 n/a 0.0318 R-0 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------ ----------------------- This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS CERTIFICATE OF COMPLIANCE .RESIDENTIAL Page 3 CF -1R CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Guest Suite Date..08/03/04 16:11:33 Project Address........ Alacano Residence ******* --------------------- Rancho La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 BarrancaPkwy, Suite F-101 Plan Check Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method ...... -MICROPAS6 x6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File -24287M21 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0940 User -Heritage Energy Group Run- ------------ ------------- ------ ----- ----------------- GENERAL un-----------------------------------------------------------GENERAL INFORMATION Conditioned Floor Area..... 544 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front.Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 27.3 % of floor area Average Glazing U -factor... 0.31 Btu/hr-sf-F Average Glazing SHGC....... 0.24 Average Ceiling Height..... 10 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R -value R -value R -value U -factor Location/Comments ------------------------------------------------- ------------------------ S1abEdge n/a R-0 R-n/a F2=0.760 S1abEdge n/a R-0 R-n/a F2=0.510 Wall Wood R-19 R-n/a R-19 0.065 RoofRadiant Wood R-30 R-n/a R-30 0.035 FENESTRATION Over - Area U- Exterior hang/ Orientation -------- ----- (sf) ------ ------ Factor -------- SHGC Shading Fins Location/Comments -------- Wind Back (N) 22.5 0.380 0.300 ----- -------------------------- Standard Yes dual wood frame low -e Door Front (S) 96.0 0.270 0.210 Standard Yes dual non metal fram low -e Wind Front (S) 10.0 0.380 0.300 Standard Yes dual wood frame low -e Wind Left (W) 20.0 0.380 0.300 Standard None dual wood frame low -e SLAB ------------- SURFACES Area Slab Type ---------------- (sf) Standard Slab ------ 544 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Guest Suite Date..08/03/04 16:11:33 HVAC SYSTEMS Refrigerant Tested ACOA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat- --- - Type Efficiency- Airflow Location R -value Leakage D Type ----------------------------- ------ ------ Furnace 0.800 AFUE n/a Attic R-4.2 No No Setback ACSplit 12.00 SEER No Attic R-4.2 No No Setback Minimum Heating Load: 11,578 Btuh Cooling Load: 11,466(Sensible),13,759(Total) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. That individual is required to provide Form CF -6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF -6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the compliance documentation. WATER HEATING SYSTEMS As per UPC chapter 5: The minimum capacity for water heaters shall be in accordance with the first hour rating listed in Table 5-1 below. -----------------------------------------------------= ________________ Number of Bathrooms 1 to 1.5 2 to 2.5 3 to 3.5 ------------------------- ----------- --------------_ _______________ Number of Bedrooms 1=1=2= 3 2 3 4 5 3 4 5 6 ------------ --_ ___ 1st. Hour Rating, Gallons 42 54 54 54 67 67 80 67 80 80 80 SPECIAL FEATURES AND MODELING ASSUMP^IONS------------------ ----------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specificat-ons, and *** *** verified during plan check and field inspect=on. *** This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS Number Tank External Tank Type Heater Type Distribution Type ---------------------------------------- in System Energy Size Factor (gal) Insulation R -value -- ------ Storage Gas Standard -------- 1 ------ ---------- 0.60 50 R- n/a RHEEM MODEL ## RHG PRO50-40 (OR EQUAL) FIRST.HOUR RATING, GALLONS (83) As per UPC chapter 5: The minimum capacity for water heaters shall be in accordance with the first hour rating listed in Table 5-1 below. -----------------------------------------------------= ________________ Number of Bathrooms 1 to 1.5 2 to 2.5 3 to 3.5 ------------------------- ----------- --------------_ _______________ Number of Bedrooms 1=1=2= 3 2 3 4 5 3 4 5 6 ------------ --_ ___ 1st. Hour Rating, Gallons 42 54 54 54 67 67 80 67 80 80 80 SPECIAL FEATURES AND MODELING ASSUMP^IONS------------------ ----------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specificat-ons, and *** *** verified during plan check and field inspect=on. *** This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS COMPUTER METHOD SUMMARY Standard Page 1 C -2R Project Title.......... Custom Residence Date..12/01/04 14:44:58 Project Address........ Alacano Residence ******* ---------------------. ---------- - -0.59 = = Space Cooling.......... Rancho La Quinta *v6.01* 33.04 1.34 = Documentation Author... Sam Maimone ******* Building Permit 0.88 = Heritage Energy Group 41.79 40.16 1.63 = 15375 Barranca Pkwy, Suite F-101 Plan Check Date Type ----------- Irvine, CA 92618 (sf) -------- Credit --------- Climate Zone..... ..... 949-789-7221 15 Field Check/ --------------------- Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01' File -24287M11 Wth-CTZ15S92 Program -FORM C -2R 0.18 User#-MP0940 User -Heritage Energy Group ----------------------- --------------- ------- ------ Run - ----------------------- 2.0 ----------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design Margin = = Space Heating.......... 3.12 ---------- 3.71 ---------- - -0.59 = = Space Cooling.......... 34.38 33.04 1.34 = = Water Heating.......... 4.29 3.41 0.88 = _ Total 41.79 40.16 1.63 = _ *** Building complies with Computer Performance Zone Type 1 Residence 2 Residence 3 Residence GENERAL INFORMATION Conditioned Floor Area..... 6645 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 4 69443 cf 6645 sf 18.1 % of floor area 0.38 Btu/hr-sf-F 0.33 10.5 ft BUILDING ZONE INFORMATION Floor ------------------------- # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage (sf) ----- (cf) ------- Units ----- itioned ------- Type ----------- (ft) ----- (sf) -------- Credit --------- 2993 32923 0.47 Yes Setback 2.0 Standard No 1166 11660 0.18 Yes Setback 2.0 Standard No 1479 14790 0.19 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Custom Residence Date..12/01/04 14:44:58 BUILDING ZONE INFORMATION -------------------------- .Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone.Type (sf) (cf) Units itioned Type (ft) (sf) Credit -------------- ------------ ----------------------- ----- -------- --------- 4 Residence 1007 10070 0.16 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments --------------- ------ ----- ----- --- ---- ----------------- ---------------- 1 6 Wall 608 0.065 19 180 90 Yes None 10 Wall 243 0.065 19 270 90 Yes None 14 Wall 530 0.065 19 0 90 Yes None 17 Wall 659 0.065 19 90 90 Yes None 20 Wall 250 0.065 19 0 90 No None 21 RoofRadiant 2993 0.035 30 n/a 0 Yes None 2 7 Wall 144 0.065 19 180 90 Yes None 11 Wall 462 0.065 19 270 90 Yes None 22 RoofRadiant 1166 0.035 30 n/a 0 Yes None 3 8 Wall 231 0.065 19 180 90 Yes None 12 Wall 236 0.065 19 270 90 Yes None 15 Wall 474 0.065 19 0 90 Yes None 18 Wall 477 0.065 19 90 90 Yes None 23 RoofRadiant 1479 0.035 30 n/a 0 Yes None 4 9 Wall 435 0.065 19 180 90 Yes None 13 Wall 148 0.065 19 270 90 Yes None 16 Wall 415 0.065 19 0 90 Yes None 19 Wall 247 0.065 19 90 90 Yes None 24 RoofRadiant 1007 0.0.35 30 n/a 0 Yes None PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1 1 SlabEdge 249 0.760 R-0 No 5 SlabEdge 25 0.510 R-0 No 2 2 SlabEdge 76 0.760 R-0 No 3 3 SlabEdge 132 0.760 R-0 No 4 4 SlabEdge 146 0.760 R-0 No COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Custom Residence Date..12/01/04 14:44:58 FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ --------=--------------- 1 1 Door Back (S) 192.0 0.270 0.210 180 90 Standard dual non metal fram low - 2 Wind Back (S) 48.0 0.350 0.350 180 90 Standard dual wood frame low -e 3 Door Back (S) 48.0 0.270 0.210 180 90 Standard dual non metal fram low - 4 Wind Back (S) 6.0 0.380 0.300 180 90 Standard dual wood frame low -e 9 Door Right (W) 96.0 0.270 0.210 270 90 Standard dual non metal fram low - 10 Door Right (W) 112.0 0.530 0.510 270 90 Standard dual pane 17 Door Front (N) 96.0 0.270 0.210 0 90 Standard -dual non metal fram low - 18 Wind Front (N) 24.0 0.350 0.350 0 90 Standard -dual wood frame low -e 19 Wind Front (N) 10.0 0.380 0.300 0 90 Standard dual wood frame low -e 25 Wind Left -(E) 37.5 0.380 0.300 90 90 Standard dual wood frame low -e 26 Wind Left (E) 4.5 0.380 0.300 90 90 Standard dual wood frame low -e 27 Wind Left (E) 5.4 0.380 0.300 90 90 Standard dual wood frame low -e 28 Wind Left (E) 20.0 0.380 0.300 90 90 Standard dual wood frame low -e 2 5 Door Back (S) 96.0 0.530 0.510 180 90 Standard dual pane 11 Wind Right (W) 13.5 0.380 0.300 270 90 Standard dual wood frame low -e 12 Wind Right (W) 25.0 0.380 0.300 270 90 Standard dual wood frame low -e 13 Wind Right (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e 3 6 Wind Back (S) 9.0 0.380 0.300 180 90 Standard dual wood frame low -e 14 Wind Right (W) 4.5 0.380 0.300 270 90 Standard dual wood frame low -e 15 Wind Right (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e 20 Wind Front (N) 20.0 0.380 0.300 0 90 Standard dual wood frame low -e 21 Wind Front (N) 36.0 0.380 0.300 0 90 Standard dual wood frame low -e 29 Wind Left (E) 9.0 0.380 0.300 90 90 Standard dual wood frame low -e 30 Wind Left (E) 4.5 0.380 0.300 90 90 Standard dual wood frame low -e 31 Wind Left (E) 30.0 0.380 0.300 90 90 Standard dual wood frame low -e 4 7 Wind Back (S) 20.0 0.380 0.300 180 90 Standard dual wood frame low -e 8 Wind Back (S) 15.0 0.380 0.300 180 90 Standard dual wood frame low -e 16 Door Right (W) 112.0 0.530 0.510 270 90 Standard dual pane 22 Wind Front (N) 20.0 0.350 0.350 0 90 Standard dual wood frame low -e 23 Wind Front (N) 20.0 0.380 0.300 0 90 Standard dual wood frame low -e 24 Wind Front (N) 15.0 0.380 0.300 0 90 Standard dual wood frame low -e 32 Wind Left (E) 13.5 0.380 0.300 90 90 Standard dual wood frame low -e OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface -(sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- --------- 1 1 Door 192.0 n/a 8 16 3 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 48.0 n/a 2 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 48.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 9 Door 96.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 10 Door 112.0 n/a 8 12 2 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 24.0 n/a 2 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 10.0 n/a 5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 4.5 n/a 3 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 5.4 n/a 1.5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 20.0 n/a 5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 2 COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Custom Residence Date..12/01/04 14:44:58 OVERHANGS AND SIDE FINS SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 2993 2 Standard Slab 1166 3 Standard Slab 1479 4 Standard Slab 1007 ---Window-- ------Overhang----- ---Left Fin---. ---Right Fin -- Area Tested ACCA Left Rght Charge and Duct Duct Duct Manual Duct Type ------------- Surface -(sf) Wdth ----- Hgth ----- Dpth ---- Hght ---- Ext ---- Ext ---- Ext ---- Dpth Hght Ext Dpth Hght 5 Door 96.0 n/a 8 12 2 n/a n/a n/a ---- n/a ---- n/a ---- n/a ---- n/a ---- n/a 12 Window 25.0 n/a 5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.637 3 6 Window 9.0 n/a 3 12 2 n/a n/a n/a n/a n/a n/a n/a n/a 4 No No 0.637 4 Furnace 0.800 AFUE 16 Door 112.0 n/a 6 12 2 n/a n/a n/a n/a n/a n/a n/a n/a 23 Window 20.0 n/a 3 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 15.0 n/a 5 2 1 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 2993 2 Standard Slab 1166 3 Standard Slab 1479 4 Standard Slab 1007 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency ----------- Airflow Location R -value Leakage D Eff 1 -------------------- ---------------- -------- ---- Furnace 0.800 AFUE n/a Attic R-4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4..2 No No 0.637 2 Furnace 0.800 AFUE n/a Attic R-4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.637 3 Furnace 0.800 AFUE n/a Attic R-4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.637 4 Furnace 0.800 AFUE n/a Attic R=4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4..2 No No 0.637 WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type ------------ Heater ----------- Type Distribution Type ------------------- System Factor (gal) R -value 1 Large Gas Recirc/TimeTemp -------------- 1 n/a ------ 100 ---------- R-12 COMPUTER METHOD SUMMARY Page 5 C -2R Project Title.......... Custom Residence Date..12/01/04 14:44:58 WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency ---Input -Fraction----R_value ' Light ------------ -- ---------------------- 1 Large 0.76 n/a 0.0318 R-0 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented cn the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses,.rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates non-standard Water Heating System REMARKS COMPUTER METHOD SUMMARY Standard Page 1 C -2R Project Title. . Project Address........ Guest Suite Date..08/03/04 16:11:33 Space Heating.......... Alacano Residence *******_____________________. ----------- -0.23 - = Space Cooling.......... Rancho La Quinta *v6.01* 4.09 = = Water Heating.......... Documentation Author... Sam Maimone ******* Bui ing Permit 97.05 Heritage Energy Group -------- - 9.38 = _ *** Building complies with Computer Performance 15375 Barranca Pkwy, Suite F-101 Plan C ec Date Irvine, CA 92618 Climate Zone.. ........ 949-789-7221 15 Fie C ec Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File -24287M21 Wth-CTZ15S92 Prcgram-FORM C -2R User##_MP0940 User -Heritage ---------------- -------------------------------------------------------- Energy Group Run- I ------------------ MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) ------------------------ Design ---------- Design Margin = Space Heating.......... 3.67 ---------- 3.90 ----------- -0.23 - = Space Cooling.......... 58.44 54.35 4.09 = = Water Heating.......... 34.94 29.42 5.52 - = Total 97.05 -------- 87.67 -------- - 9.38 = _ *** Building complies with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 544 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Zone Type -------------- 1 Residence. Slab On Grad -- 1 5440 cf 544 sf 27.3 % of floor area 0.31 Btu/hr-sf-F 0.24 10 ft BUILDING ZONE INFORMATION ------------------------- Floor ## of Vent Vent Air Area Volume Dwell. Cond- Thermostat Height Area Leakage (sf) (cf) Units itioned Type (ft) (sf) Credit ------------ ----------------------- ----- -------- --------- 544 5440 1.00 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title....:..... Guest Suite' Date..08/03/04 16:11:33 OPAQUE SURFACES Surface ----------- 1 1 SlabEdge 2 SlabEdge PERIMETER LOSSES ---------------- Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments --------------- ----- ---------------------- 84 0.760 R-0 No 17 0.510 R-0 No FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ----- ----- --- ------------ ------------------------ 1 1 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e 2 Wind Back (N) 4.5 0.380 0.300 0 90 Standard dual wood frame low -e 3 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e 4 Door Front (S) 96.0 0.270 0.210 180 90 Standard dual non metal fram low - 5 Wind Front (S) 10.0 0.380 0.300 180 90 Standard dual wood frame low -e 6 Wind Left (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght --- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 ---- 1 Window 9.0 n/a 8 16 3 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 4.5 n/a 2 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 9.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 96.0 n/a 8 12 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 10.0 n/a 3 12 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 544 Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor ----- R-val ----- Azm --- Tilt Gains Reference Comments 1 ---- ----- ------------ ---------------- 3 Wall 328 0.065 19 0 90 Yes None 4 Wall 224 0.065 19 180 90 Yes None 5 Wall 140 0.065 19 270 90 Yes None 6 Wall 170 0:065 19 180 90 No None 7 Roof Radiant 544 0.035 30 n/a 0 Yes None Surface ----------- 1 1 SlabEdge 2 SlabEdge PERIMETER LOSSES ---------------- Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments --------------- ----- ---------------------- 84 0.760 R-0 No 17 0.510 R-0 No FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ----- ----- --- ------------ ------------------------ 1 1 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e 2 Wind Back (N) 4.5 0.380 0.300 0 90 Standard dual wood frame low -e 3 Wind Back (N) 9.0 0.380 0.300 0 90 Standard dual wood frame low -e 4 Door Front (S) 96.0 0.270 0.210 180 90 Standard dual non metal fram low - 5 Wind Front (S) 10.0 0.380 0.300 180 90 Standard dual wood frame low -e 6 Wind Left (W) 20.0 0.380 0.300 270 90 Standard dual wood frame low -e OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght --- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 ---- 1 Window 9.0 n/a 8 16 3 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 4.5 n/a 2 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 9.0 n/a 8 16 1 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 96.0 n/a 8 12 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 10.0 n/a 3 12 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 544 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Guest Suite Date..08/03/04 16:11:33 HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value -- ----------------- -------------- ------ ---------- 1 Storage Gas Standard 1 0.60 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented cn the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS Refrigerant Tested ACOA System Minimum Charge and Duct Duct Duct Manual Duct ---Type------ Efficiency ---- Airflow Location -------------------- R -value Leakage D Eff 1 ------- --------- -------- ---- Furnace 0.800 AFUE n/a Attic R-4.2 No No 0.743 ACSplit 12.00 SEER No Attic R-4.2 No No 0.637 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value -- ----------------- -------------- ------ ---------- 1 Storage Gas Standard 1 0.60 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented cn the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. REMARKS