Loading...
BMCH2016-044778-495 CALLE TAMPICO D VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN &'DEVELOPMENT DEPARTMENT • INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 12/13/2016 Application Number: BMCH2O16-0447 Owner: Property Address: 49025 VISTA ESTRELLA DAVID CROCKETT APN: 602240024 � s,^� a 9025 VISTA ESTRELLA Application Description: CROCKETT RESIDENCE / HVAC CH kIjIGEfO T QUINTA, CA 92253 Property Zoning: v Application Valuation: $11,000.00. DEC 14 2016 Applicant: Contractor: CERTIFIED COMFORT SYSTEMS INC DBA HYDES CITY OF LA QUINTA p� RTIFIED COMFORT SYSTEMS INC DBA HYDES 42-949 MADIO STREET DESIGN AND DEVELOPMENT UEPARTMEC-949 MADIO STREET INDIO, CA 92201 INDIO, CA 92201 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 906115 Date:�0,6 Contractor: OWNER-BUILDEREC TION I hereby affirm under penalty of perjury that I empt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for permit subjects the applicant'to a civil penalty of not.more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builderwill have the burden of proving that he or she did not build or improve for the purpose.of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (760)360-2202 Llc. No.: 906115 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EVEREST NATIONAL INSURANCE COMPANY Policy Number: 7600015264 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I hall forthwith comply with those provisions. Date:12,6, Applicant: WARNING: FAILURE TO SECURE WORKERS' C ENSAT COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRI AL PE IES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($10 ,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to . the conditions and restrictions set'forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the'above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-ment'ned property for inspection purposes. Date'' Signature (Applicant or Agent Date: 12/13/2016 . Application Number: BMCH2O16-0447 Owner: Property Address: 49025 VISTA ESTRELLA DAVID CROCKETT APN: 602240024 49025 VISTA ESTRELLA Application Description: CROCKETT RESIDENCE / HVAC CHANGE OUT LA QUINTA, CA 92253 Property Zoning: Application Valuation: $11,000.00 Applicant: Contractor,. CERTIFIED COMFORT SYSTEMS INC DBA HYDES CERTIFIED COMFORT SYSTEMS INC DBA HYDES 42-949 MADIO STREET 42-949 MADIO STREET INDIO, CA 92201 INDIO, CA 92201 (760)360-2202 -------------------------------------------------------------------------------.-------------- Uc. No.: 906115 Detail: (2) HVAC CHANGE OUT -.16 SEER/80AFUE SPLIT SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2013 CALIFORNIA BUILDING CODES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: . $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT -SPLIT-SYSTEM 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT -SPLIT-SYSTEM PC 101-0000-42600 0 $76.00 Total Paid for CHANGEOUT: $228.00 DESCRIPTION ACCOUNT. QTY AMOUNT PERMIT ISSUANCE 101-000042404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 I CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R7ALT HVAC) (Page 1 of 3 ) Project Name: 49025 Vista Estrella Date Prepared: 2016-12-13 A. General Information ` CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one MR -ALT -02 document for each dwelling unit. 01 Project Name 49025 Vista Estrella 02 Date Prepared 2016-12-13 03 Project Location 49025 Vista Estrella 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 49025 Vista Estrella 07 Zip Code 92253 08 Dwelling Unit Conditioned 2000 Installing new SC Installing Installing Installing Floor Area (ft2) . Location or Area . by this SC ducted containing Number of space conditioning more than 40 09 Climate Zone 15 10 (SC) systems in this dwelling 2. system? component? components? feet of ducts? unit. SC system? B. Space Conditioning (SC) System Information 01 02 03 04 �05a ; -06 `t`2-1 07_ 08 09 10 '',Is the SC Installing a SC System SC System CFA served system a'' refrigerant Installing new SC Installing Installing Installing Identification or Location or Area . by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 living area 1200 Yes Yes. Yes No No No . Altered space conditioning system System 2 bedrooms 1200 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)iDiib) This section does not apply to this project. Registration Number: 216-A0459560A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-12-13 10:28:52 Report Version: 2013 Rev 1.008 Schema Version: 0.555SDD HERS Provider: CaICERTS Report Generated: 2016-12-13 .10:29:29 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 .04 05 06 07 08 09 10 it 12 Heating Cooling System Heating Altered Heating. Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New.Duct 'or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 78 AC cooling SEER 13 Setback section is not section is not components components applicable applicable Central gas All new Central split All new This field or ' This field or System 2 furnace heating AFUE 78 AC cooling SEER 13 Setback section is not section is not components components applicable applicable Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or whenmore than 40 ft of duct length is replaced. -Leakage.rate compliance: 5 15%, or15 10% leakage to outside, or seal all accessible leaks. CF2R-MCH=25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing.compone_nts are installed or'altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required. when MCH-25.is required. a' Exceptions: - -Duct systems registered with HERS provider as previously sealed are exempt from. MCH -20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require.verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. .E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section. does not apply to this project. Registration Number: 216-A0459560A-000000000-0000 Registration Date/Time: 2016-12-13 10:28:52 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 - Schema Version: 0.5555DD HERS Provider: CalCERTS Report Generated: 2016-12-13 10:29:29 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: 11 J Hyde, Mark' QiP/ Company: Signature Date: CERTIFIED COMFORT SYSTEMS INC 2016-12-13 10:28:52 Address: CEA/ HERS Certification Identification (if applicable): 42949 Madio City/State/Zip: Phone: Indio CA 92201 760-360-2202 Responsible Person's Declaration -statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the 'ti requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on'this Certificate.bf Compliance are consistent with the information provided omothe_r applicable`compliance documents, worksheets, calculations, plans and specifications submitted tothe enforcement agency for,approval with this building permrt application. S. I will ensure that a registered copy of this Certificate of Compliance shall be made available with:the building permit(s) issued for'the building, and made available to the'enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is..required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name:Responsible Designer Signature: Hyde, Mark Company: Date Signed: - CERTIFIED COMFORT SYSTEMS INC 2016-12-13 10:28:52 Address: License: 42949 Madio 906115 City/State/Zip: Phone: Indio CA 92201 760-360-2202 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. R• Registration Number: 216-AO45956OA-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: , 2016-12-13 10:28:52 Report Version: 2013 Rev 1.008 Schema Version: 0.555SDD HERS Provider: CaICERTS Report Generated: 2016-12-13 10:29:29