Loading...
0307-315 (RPL)LICENSED CONTRACTOR DECLARATION U) I hereby affirm under penalty of perjury that I am licensed under provisions of H Chapter 9 (commencing with Section 7000) of Division 3 of the Business and WProfessionals Code, and my License is in full force and effect. O M C) License # Lic. Class Exp. Date r- X r- 8 U1 s" B 05 3�_ �J I31 i2i Z r- Date '21 2'A Signature of Contractor � Oo OWNER -BUILDER DECLARATION co W W r– I hereby affirm under penalty of perjury that I am exempt from the Contractor's ~ U) License Law for the following reason: Z_ ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner,of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ce) () I am exempt under Section , B&P.C. for this reason L N Date Signature of Owner p cv d Q WORKER'S COMPENSATION DECLARATION p X I hereby affirm under penalty of perjury one of the following declarations: Lo H p () 1 have and will maintain a certificate of consent to self -insure for workers' X W LL: compensation, as provided for by Section 3700 of the Labor Code, for the O J Q performance of the work for which this permit is issued. M Q () ( ) I have and will maintain workers' compensation insurance, as required by O U Q Section 3700 of the Labor Code, for the performance of the work for which this d rn H permit is issued. My workers' compensation insurance carrier & policy no. are: cb ZCamer Ee3�Tv3PT Policy No. ao 0 r` 0 J (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become 3 subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions_f_l` ate: ; i u. Applicant - -/ ��.. .. Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify,— & hold harmless the City of La Quinta, its officers, agents and employees",1 2. Any permit issued as a result of this application becomes null and void if jJ work is not commenced within 180 days from date of issuance of sucFi'� permit, or cessation of work for 180 days will subject permit to cancellationM I certify that I have read.this application and state that the above information Is ' correct. I agree to comply with all City, and State laws relating to the building" construction, and hereby authorize representatives of this City to enter upon the above-mentioned property, for inspection purposes. + ` Signature (Owner/Agent)(' �� vac Date /r iY •:i�t'rur iey .i art'•} � / BUILDING PERMIT PERMITtf DATE VALUATION LOT 0307^315 TRACT 1 . , S2UM.00 JOB SITE APN ADDRESS 44_ j10 VIS.+1;r OWNER CONTRACTOR/DESIGNER/EN (NEER CHARLES S7f.Off'ORD 1♦ P 1) b1MV-1 44.31 CS vuizm imov. 80-228 GOLD E'NORS T� OE LA QUINTA W..0110 C 92201 (760)32.x:-779. 6 CBLO USE OF PERMIT POOL AN.I IDR SPA. FIBERCLASS PC OUS3PA. ALAR11+I"ali9.iaRtZIEir'S'SHAL1, k3,'V IN PLACE .AT P.i2FMASTER MISPWTION, EQUIPMENT 1±i+IC1,08"IR : NOT INCLUDED POOL AND/OR SPA 21,000.00 1 EM9i:IN1A'1T• D COST OF C011TYMII3MON .25 000.00 PM;MU'F FEE RUAMMY PLA14 t"HWK E& 101.000.4.351=3118 C:ONSIPPLUCTION Fn 101-000-418-000 $3552,00 . WCHANI ,ALF ^- POOL 101.000.42:1-000 $24.00 FLF:.MUC.J'AT..Me.. Pool. lilt -000 -424 -OW x•5.40 PLtJMB1140 FEE -• POOL 101-000-419-000 $27M i SUB TOTAL COi,1MUM.IQ11 "D .PLAN CIMM. $311.80 LESS PRE-PA!'%� . � , 9 $0.00 ff °°�� i i <.^ii1 _ L! 1� W1.£9 �. Tod' awr �'1�q- DUE NOW JUL 2 3 iL]13 , J RECEIPT DATE BY �� DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plembing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover -Sewer Connection Encapsulation Gas Piping Gas Test Appliances ` Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Law Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: ICBO Evaluation Set -vice Inc. 5360 WORKMAN h1lILL ROAD - VUHITTIER, CALIFORNIA 90601-2299 A subsidiarycorpol-a/ion of/he International Conference of EVALUATION REPORT` l:ulryriyhl Cv 2000 IC8O Evaluation Service, Inc. Filing Category: SWIMMING POOLS AND SPAS (266) FIBERGLASS ONE-PIECE SWIMMING POOLS AND SPAS ,!IK1143 POOLS, INC. 1'0,ST OFFICE BCX 96 :'d.'L.L:AMS, CALIFORNIA 95987 1.0 SUBJECT Fioerola:s One-piece Swimming Pools and Spas. 2.0 DESCRIPTION 2.1 General: he swimming pools and spas consist of one-piece fiberglass ccnstruc;on shod formed over a mold. The material is fiber- Olass reinforced plastic, 1/4 inch (6.4 mrn) thick, composed of isophtali c resin, vinyl ester resin, fiberglass, and ceramic. The surface finish is a neo pentyl glycol gel coat_ Viking Pools, Ir,c_, produces various styles of swimming pools and spas. The overall pool dimensions, depths and capacities are shown in Table 1. For mini -pools, see Table 2; for spas, see TaLle 3. e Lain models described in Table 4 can be placed up to i 91;, inches ;49.5 r,m) above ground. Vertical supports con- s!s1Jno o31 -inch -by -11/2 -inch -by -36 -inch -long (25 mm by 38 m-:. by 914 rnm) Dcuolas fir No. 2 wood members encapsu- lated in to FRP process at 4 -foot 6 -inch (1372 mm) intervals E -e reouirec. These pools and spas nay be placed with or -v;'hout concrete or wood .pecking. Unless elevated portions o' the uni is are protected from sunlight by soil berms, decking, eiz , these, portions must be coated with a UV -inhibiting caaoue paint that is compatible with the laminate. The fiberglass has an average tensile strength of 13,308 psi k:;1.76 MiPa), ultimate compressive strength of 23,400 psi (161.34 N,Pa) and ,flexural strength of 41,976 psi (450.75 MPa). The upper portion of the in -ground pools and spas is constrained by a concrete -bond beam. See Figures 1 and 2 for details. For aboveground models, see Table 4 and Fig- ure 3. All plumbing and electrical work must comply with The code currently in efiect at the construction site. The pool and spa must remain full of water at all times. A permanent sign must be attached to the pumping equipment with the following in- formation: Notice—The pool or spa is designed to remain full of water at all times. The pool shell may be damaged if the water lev- el is allowed to drop below the inlet. When appreciable d raw -d own is noticed or if it becomes necessary to drain the pool or spa, contact Viking Pools, Inc., or its agents for in- structions. A permanent label must be installed adjacent to the above sign by the manufacturing licensee giving his name, address and telephone number. Accredilod by 1ho American National Standards Insthulo Building Officials PFG -3608 Reissued June y, 2000 2.2 Installalion. Viking pools and spas may be installed without a soil inves- tigation by a qualified engineer, subject to the building offi- cial's approval, provided none of tie following conditions are encountered at the site: 7. The existence of groundwater within depth of the pool or spa excavation. 2. The existence of an uncompacted fill in contact with any portion of the pool or spa. 3. The existence of any expansive or adobe -type soils. 4. The existence of any soil types with an angle of repose that will not support the walls of the excavalion at desired slopes. 5. Proposed pool or spa location endangers adjacent struc- tures. 6. The existence of any cracks or openings in soil that would not confine sand bedding_ if any condition above is encountered, excavation must cease immediately. The specified conditions at the site must then be reviewed and recommendations made by a qualified engineer. The building official must approve the engineer's report before work is continued. The pool or spa excavation profile must coincide with the contours of the pool. The overexcavation is approximately 6 inches (152 mm) on the sides and 12 inches (305 mm) on the ends. At the deep end, the pool width is overexcavaied from 8 to 24 inches (203 to 610 mm) so the first portion of the back- fill can be manually adjusted forthe initial 12 inches (305 mm) of backfill. The overexcavation near the pool bottom varies from approximately 3 to 6 inches (76 to 152 mm), depending on soil type. The backfill for the pool or spa bottom is a layer of bedding sand. This sand layer is compacted using a manu- al tamper and water. Simultaneous watefiil and sand backfill operations then commence. The sand is compacted with a tamper and water. The installer must ensure that the backfill level and water level are approximately the same throughout this procedure. The pools and spas are installed only by facto- ry trained and approved agents or by franchised installers in accordance with the requirements of this report. Decks are prepared as indicated in Figures 1 through 3. De- tails specifically for installations in expansive, clay, or adobe soils apply only when supported by the engineer's recom- mendaSons and approved by the building official. f=orms are placed around pool or spa perimeters. Where chains occur, pockets measuring 12 inches (305 mm) wide and 6 inches (152 mm) deep are prepared under the perimeter excavation to ensure anchorage. The concrete is placed within 1/4 inch (6.4 mm) of coping top and sloped away for drainage. Cantilevered concrete decks are constructed as noted in Figure 2. In all cases, when concrete decks are installed, the Evaluation reports ofICBO Evaluation Service, Inc., are issued solely to provide information to Class membersofJCBO, utilizing the code upon which the report is based. Evaluation reports are not to be construed as representing aesthetics or any otherattributes not specifically addressed nbrasan endorsement orrecommen - dation for use ojthe subject report. This report is based upon independent tests or other technical data submitted by the applicant. The JCBO Evaluation Service, Inc, technical staff has reviewed the test results and/arother data, butdoes not possess test facilities to makean independent verification. There is no warranty by ICBG Evaluation Service, Inc_, express or implied, as to any "Finding" or other matter in the report or as to any product covered by the repri This disclaimer includes, but is not limited to, merchantability. Page 1 of 4 Page 2 of 4 _ ,- PFC-3608 .%.i ;rat cfeptt. of the concrete in the chain pockets should mea s1„ e 12 inches (305 mm). - 4.0 FlND1NGS Barriers are required where pools are on premises of Group H„ Division That the Viking Pools, Inc., Fiberglass One-piece Swim - ming Pools and Spas comply, with the 1997 Uniform 3, Occupancies. The barriers must comply will) . Appendix Chapter 9, Division !, of the code. 8vAd/ng Code'"", subject to the following conditions: EK 4.1 The construction and pool spa Installation comply 2.3 identification+: with this report and the manufacturer's instruc- Uniform depth tions. Viking pools are identified b the following Y g information im 4.2 Electrical and plumbing In comply with ' printed on the top step of the pool or spa: Manufacturer's the respective codes In effect at the construction name, poolor spa model designation, a -coded serial number site. and evaluation report number. 4.3 The pools and spas are installed by factory -trained ' The aboveground units also bear the label of the quality or licensed installers or agents approved by Viking Pools, Inc. control agency, Columbia Research & Testing Corporation 13 30 - ,AA -527). 4.4 Clearances from slopes as set forth in Section 12-0 1806.5.4 of the code are observed. 3•tl=V1D�fdCE SUSMlT3 ED 4.5 The pools and spas are produced by Viking Pools 6-0 at 121 Crawford Road, Williams, California. Ele- Plans, fabrication and installation data, calculations and a valed units have quality control inspections by Co - lumbia Research & Testing Corporation (AA -527). quality control manual. This report is subject to re-examination in two 5 -0 years TABLE 7—POOLS __SERIES LENGTH (I L 31-) Deep End (ri-In.) 37-0 £ t 25-2 1 3-6 34-0 EK 24-0 RC t 3i-4 Uniform depth 28-0 _ 1 - - 1 25-7 G p 33-0 rr j 30-0 B KD SL BP SF RS GC os U 3'P CD BPD CP MY AC 013 Lr_T_ 24-0 39-0 38-0 24-0 30-0 40-0 35-0 31-0 25-0 33-0 38-0 31-0 35-0 39-0 4d-0 30-0 1 DEPTH WIDTH (fttin.) Deep End (ri-In.) Shallow End (hAn.) 34-0 7-0 1 3-6 35-0 8-3 3-S 31-30 4-b Uniform depth 3 5-0 8-3 3-5 13-30 _ 4-6 Usirormdeptb 34 0 5-10 3-4 14-0 5-10 3-6 13 30 - 4-6 Uniform depLh . 12-0 b-0 3-6 3 5-D 6-0 3-6 1.4-0 6-D 3-6 12-0 5 -0 3_6 7-b 4-0 Uniform depth 16-0 6-0 3-6 12-0 6-0 ! 3-6 34-0 .6-6 3-6 16-0 8-0 3-6 16-0 5-10 3-6 34-0 5-10 3-6 - 32^0 5-5 3-6 16-0 5-6 3-6 ' 16-0 8-0 3-5 ' 120 5-0 3-6 14-0 5-6 3-6 16-0 6-0 3-6 16-0 5-8 3-6 14-0 6-0 3-6 CAPACrrY (gm 13.700 20.000 8.103 16,030 .6.000 14,000 3 0,000 34,ODG 9,0M3 34,8D0 12,000 6.0D0 6,503 17,000 9,000 32.500 19.600 15,000 12,800 6,000 15,OD0 20,000 10.500 12,400 16,700 18,900 12,000 Pa`` 3 of4 PFC-3608 - •a TABLE 2 -1011141 -POOLS SERIES - LLNGIH !l: )n. _ ( ) - - WIUI H (!l: ln.) Uccp Lpd (!1. -in.) — —_ — •-- — - DLP) il Shallow Cod CAPACITY (gal.) 14.6------ 9 G A-0 Uniform dcpUl 2.5(11 • - A377� 74-U . R -U, _ 4.0 ,Uniforrm dcpdL 2. 100 __... 7,911• 1.5.10 g.5 _ 4 0 Uniform depth 2,2M . + M1'K !G•p 9.3 -- _ 4.0 34 2,300 75.0 9-6 4-6 Uniform dcpol 2.100 SAP 1 21-(1 9-6 4-0 Uniform dcplh 2.800 p 18-0 30.0 5-U Uniform dcpUl 2,600 S J_ S P i 20-0 11-0 5.0 3-5 3.600 }Et 22-0 7 6 • 4-0 Uniform dep111 . 3.5()0 20-0 10.0 5.0 . 3 6 2.75f) — \\SGA 38.0 8-6 G•fJ Uniform de U; 3.500 G-0 5-6 3.250 8-0 f -6 5-6 Unilbrm dcptil 3.0(YJ WGA 3 8-0 E-6 2.750 \,'GL J g_0 8.6 5-0 Uniform depth 2.500 TABLE 3—SPAS . SzRIE£ '• ! SHAPE 1 YADTH OR DIAMETER (1L -in.) I DEPrH (n,in.) CAPACr Y (gel.) 1 Hound 5.8 3-0 275 OS OctagonalEJ 6-0 . 3-0 375 1 SS Square 6-6 3-0 295 _.OS Octagonal 7-6 3-0 450 1 RS �' Round 7-0 3-0 los OctagonalS-0 j 3-0 _420 475 CS - Gct omai g S -Ox 32-0 3-0 " 700"` TABLE 4—ABOVEGROU14D (19112'incbes) ASP PoflLs M rr SAP 1 SPAS WGA BOS LRS$ MK SK WGB CS OS BFf .. M Si WGC S SS BK3� MP SP WGD 1=P MTK TE \\'GE HL.. Page 4 of 4; PFC-3608. • -•- J'U' MIIJ Witt MIST/UI - � o' Y. A• _\VI.�) N•1,.( -- _ __ I:I�N lJ(� 3•C.YJ 7'O.C."O'MVJ. N'KI W.'.M OI !• StOl71Y 1/�• 1' ' - 9' —' CW C1.AY IAIJOe1J .. - _— -- —_—J4J1nC.7JO..:1.:71J"]:-0•L. - _ -1100 OIJIY DiCN'GJ lN_r - q• b.Ul wnY, 701. CNX 1AY ItiD.h1') J7'. .. , __ .t1��yyJ^r����" /, /, J. , lIl G' ' • � J• �- TY'—T-%Y-7'-]� � - • - _ I11=11t-111-dH= �-, _ _ •_ =-=� `r�_-- 1'I(- =11I - � � .� II1-111-11i-11t- •-7 t)1 , ' •`" II `1/.•GNvealitu 111=111= ill 1� . =T1I - �. r ... :•%..�,Lc,. _=�--c+:nsv— ---�-" "— ,• _-11 1���`'/''cN�A/r�t�ill=ili lil _ _ t � tol CV.Y 4 • � Qynll]- ' J;!-•1. •-il � J' 1�O:J: CCM1rwC71 () ynu:J�l) P /OI.CIAY :•.•lJl, it Yrt;,�) y[>r; O1J/1' N n. l _ J• fH1_I: co-cRD ���-w^�� "NJl 1HK/: C.Cw•rnCTID 7�.• •.'.n1JD (fl'h',•,.11 �lJ4 V41Y if y r.w 7HCf COAVACS1i7 • _ •..r'== - ')elsCJr, f,l.cr _ - _ '7-.. •71/1 j 7l tALLA I'%CCA�Y 4-n 14x1 l;C.t,' S L IIITTT..T��- \- - �-7U• YLi.N ..12 1. LS. " FIGURE 7-TYPICAL COIJCRETE DECK FIGURE 2-TYPICAL CAtQ77LEVER CONCRETE: DECK • 741/?' r. 11fJDi4D D1Rt- — — —, MOUND POOL WOOD DKK • r • {{ AYPROX b- ` HE3i?—=9I?Eg11= it _ - C. FIGURE 3-TYPICAL ABOVEGROUND INSTALLATION CITY OF LA QUINTA SUB -CONTRACTOR LIST JOB ADDRESS Lill r5lb Y1 L,(M PERMIT NUMBER �3t>�. 3i s OWNER n BUILDER F/��(> Cis 1 This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to cominencemerit of work. Failure to comply .will result in a stoppage of work and/or the voidance. of building permit. For. each applicable trade, all information requested below must be completed by applicant. "On File". is not an acceptable response. - Contract ...:_ or,License. - ._.:.. : . <oksC4 ;W..r..._._. eaior:onInsurance . .:::.... :. . ceContrctTradense_ Company Name Classification License Number N Up. Date,. Carrier Name Policy Number Exp. Date License Number - Exp. Date (e.g: A, B, C-8) (xxxxxx) (xz/xx/xx), (e.g. State Fund, CalComp). (Format Varies)' (xx/xx/xx1. (xxxx) (xx/xx/xx) EARTHWORK (C42),-1`�� G 5 3 �d 13`2 • 5-3/-4 CONCRETE C S 3 FRAMING STRUCT.;:STEEL :(C.51). MASONRY PLUMBING �3a I�Z LATH; PLASTER (C:.351" .` HVAC: ELECTRICAL(C 10) : . ROOFING aC`z39.1`:<:>;:>:::::: SHEET METAL (C 43) PLO:ORING.fC'=1`5)?' GLAZING (C 17) aiiy INSULATIOK1C SEWAGE bISP (C;........ _ PAINTING CERAMIC. TILE. IC 54►.. y FENCING; C` 1'3 ` ' ><>:<' .LANPSCAF NG :(:C''27;) ?>' OL..IC 531:.. v � S 3 30 132— � .