08-1439 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4t!t 4'4 Qsd�& BUILDING & SAFETY DEPARTMENT BUILDING PERMIT _ W --- Z Application Number: 80.000-14.391 -- Property Address: 48239 VISTA- DE `NOPAL'_ APN:646=110=006-- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 190001 Applicant: Architect -1�or gi eer:aV�w �rinq� LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with - Section 7000) of Division 3'of the Business an ionals Cod d my License is in full force and effect. / LicenseaYasjras 13B�p nse No.: 781834 r, D. ` / Contractor: ' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to - construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the . permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Coder or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/02/09 Owner: HOLLINS HEAD, ROBERT & /) 51 VARSITY RIDGE TERR NW CALGARY CANADA T3A 2 90 U Contractor: BRAUCKMANN INC �Q�A�iyA D 50855.WASHINGTON STREET, #227 LA QUINTA, CA 92253 (760)485-9269 Lic. No.: 781834 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the'following declarations: - I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - I have and will maintain workers' compensationinsurance, as required by Section 3700 of the Labor. Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner So-pt' oa 'a subject o the workers' compensation laws of California, and agree that,. if uld becom '.s.0 ' the workers' compensation provisions of Section 3700 of the hwith comply with those provisions. ✓t . 3 D � WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS'UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. , APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is. made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the'City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subjedt permit to cancellation. I certify that I have read this application and state that the abo��!9 �i rmation is correct. I agree to comply with all city and county rdinances and state laws rel I construction, and hereby authorize representatives of is cou ty t enter Vpon the above -me ty for inspection purposes. Date: O gnature ent): Application Number . . . . . 08-00001439 ------ Structure Information 2189 SF SFD ----- Other struct info . . . . . CODE EDITION 2007 # BEDROOMS 3.00 " FIRE SPRINKLERS NO GARAGE SQ FTG 484.00_ PATIO SQ.FTG 274.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 2189.00 Permit' BUILDING PERMIT Additional desc 2189 SF SFD Permit Fee' 958.00 Plan Check Fee 622.70 Issue Date Valuation 190001 Expiration Date 8/29/09 Qty Unit Charge, Per ,Extension BASE FEE 639.50, 91.00 3.50.00 THOU BLDG 100,001-500,000 318.50 Permit ELEC-NEW RESIDENTIAL . Additional desc.. Permit Fee 116.30 Plan Check Fee '. 29.08 Issue Date Valuation 0 Expiration Date'. 8/29/09 Qty Unit Charge- Per Extension BASEFEE 15.00 2189.00 .0350 ELEC NEWRES- 1 OR 2 FAMILY 76.62 484.00 .0200 ELEC`,GARAGE OR NON-RESIDENTIAL 9.68 1:00 15:000.0 EA ELEC TEMPORARY'POWER POLE I 1 15.00, Permit MECHANICAL Additional desc .. . Permit Fee 90.00 -Plan Check Fee 22'.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/29/09 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA- MECH FURNACE <=100K 18.00 2.00 9.0000 EA, MECH B/C <=3HP/100K BTU 18.00 5.00. 6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 ----------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 LQPERMIT ' Application Number . . 08-00001439 -1 Permit PLUMBING Additional desc . Permit Fee . . . . 159.00 Plan Check Fee 39.75 Issue Date . . . Valuation . . . . 0 Expiration Date 8/29/09 Qty Unit Charge Per Extension BASE FEE 15.00 15.00 6.0000 EA PLB FIXTURE 90.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1:00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1:00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 15.0000 EA PLB'GAS METER Permit GRADING PERMIT Additional desc . Permit Fee15.00 Plan Check Fee:. .00 Issue Date . . . . Valuation, . . . . 0 , Expiration Date 8/29/09,' Qty, Unit Charge Per Extension BASE FEE. 15.00 ------------------------------------------------------------------------------- Special Notes and Comments` 2189 SF SINGLE FAMILY DWELLING. ZERO LOT LINE OCCURS AT WEST PROPERTY LINE. 2007 CODES. **PERMIT DOES NOT INCLUDE BLOCK - WALLS, FENCES, SWIMMING POOLS,.SPA, . WATER FEATURES and BBQ'S** 2007 CODES / - 2006 DIF. - Other Fees DIP COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 62.27 DIF FIRE PROTECTION-RES 140.00 DIF LIBRARIES -.RES 355.00 DIF PARK MAINT FAC - RES '22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 19.00 DIF STREET MAINT'FAC-RES 67.00 DIF TRANSPORTATION -'RES. 1930.00 Fee summary Charged Paid Credited Due LQPERMIT .y, Application Number . . . . . 08-00001439 v Permit Fee Total 133.8.30 .00 .00 1338.30 Plan Check Total 714.03 500.00 .00 214.03 Other Fee Total 4556.27 .00 .00 4556.27 Grand Total' 6608.60 500.00 .00 6108.60 LQPERAIIT 68 t 3q at P.O. BOX 1504 APPLICATION ONLY Building78-495 CALLE TAMPICO Address 2.� S-rA _r-�PA.L_IA QUINTA, CALIFORNIA 92253 Ownr �qJ S�, f�BUILDING: TYPE CONST. v OCC. GRP. / Mailing �� • "0 , Address S/ VA-esiT A.P. Number Y I� Tom, n1 u' City Zip Tel. Legal Description �-o -Te-A--r 13 % 4.O 15A �Y �q Contractor Project Description Address City Zip Tel. State Lic. City Sq. Ft. 74 CICJ No. 1 No. Dw. l & Classif. Lic. # Size Stories Units „y,., I Ll• � EAD Designer U.4 PM -_St 609 t Lk Addre s Tel. (gQ v . r"�k -+<o r L,,&- Qom, 4XTA. I I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own emploees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) . ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION !j I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company } ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation F or less). 4 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become f subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith 1!j comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY } I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip i WHITE = BUILDING DEPARTMENT New lid Add ❑ Alter ❑ Repair ❑ Demolition ❑ - t ZONE: FINANCr nr-.._ Minimum Setback Distances Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated bv: Validation: YELLOW = APPLICANT PINK = FINANCE Estimated Valuation 3�)c::> PERMIT 01R_ 1143, AMOUNT Plan Chk, Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS - t ZONE: FINANCr nr-.._ Minimum Setback Distances Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated bv: Validation: YELLOW = APPLICANT PINK = FINANCE ` iEDs� CERTIFICATE OF COMPLIANCE vZ4� Desert Sands Unified School District �p�cyo 47950 Dune Palms Road Q BERMUDA DUNES ' q G7 RANCHO MIRAGE Date 3/2/09 La.Quinta, CA 92253 INDIAN WELLS . _ �P�UINo. 30313 QNTA(760) 771-8515�NDIo y . y7� Owner Susan & Robert Hollinshead APN # 646-110-006 ii' Address 51 Varsity Ridge Terr. N.W> Jurisdiction La Quinta i CityCalgary Zip T3A-4Y2 Permit # Tract # = No. of Units 1 Type Single Family Residence Lot # No. Street S.F. Lot # No. Street S.F. .Unit 1 48239 Vista De Nopal 2189 Unit 6 Unit 2 'Unit 7 Unit 3 Unit,8,. I, Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner.is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE ,This certifies that school facility fees imposed pursuant o ,Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 2,189 S.F. - or $6,501.33 have been paid for the property listed -above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project'may now be issued. Fees Paid By CC/Rabobank - Mike Brauckmann Check No. 008001644 Name on the check Telephone 485-9269 Funding Residential By Dr. Sharon P. McGehee Superintendent'` Fee collected /exempted by Sf0 MCGIIVrey Payment Recd h.;',$p.p �x $6,501.33 T Over/ Signature NOTICE: Pursuant to Government Code Section 66020( this will serve to notify you that the 90 -day approval period in which you may protest the fees o ,r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which, those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original _ Building Department Applicant Copy -Applicant/Receipt Copy - Accounting Sent By: ; RECORDING REQUESTED BY: SOUTHLAND TITLE (Title) WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: Robert and Susan Hollinshead 51 Varsity Ridge Terrace Calgary, AS, Canada T3A4Y2 A.P.N.: 646-110-006-6 403-286-9434; Mar -2-09 9:40PM; Page 1/1 DOC # 2009—(0(0UWU 02/04/2009 08:00A Faa:9.00 Page t of 1 Recorded in official Records County of Riverside Larry U. card Assessor, County Clerk 8 Recorder 11111111111111 IN 111111111111111111111111111111 R U PAGE SIZE DA MISC LONG RFD COPY +S I M A L 485 426 Peo NNCOR SMF NCHG EXAM % T: CTY UNI SPACE ABOVE GRANT DEED 9 THE UNDERSIGNED GRANTOR(S) DEC RE(S) DOCUMENTARY TRANSFER TAX IS $0.00 This conveyance changes the manner in which title is held, grantor(s) and grantee(s) remain the some and continue to told the same proportionate interest, R 8 T 11911. ® City of La Quints FOR A VALUABLE CONSIDERATION, Robert Holllnshead and Susan Holl of which is hereby acknowledged, , husband and wife as Joint tenants hereby GRANT(S) to Robert Holllnshead ad Susan Holllnshead as tenants in common the following described real property in the Ctunty of Riverside, State of California Lot 6 of Tract No. 13640-1. in the City of as per map recorded In Book 129, Pape( Recorder of said County. Dated: February 3, 2009 State of Californ, Cou� of e t ou ft_ -k IEJYI.�ar1 3.2.00 - I a :�A41an S I L I, n S K e q who prove me on the basis of satisfactory evic the pam (s) hose nam s s r subscribed tc Inslrumen nd acknowle�ed me that t executed the samIsTher it uthorized cu and that by his/hithe signatu n the inst person( ) or the upon behal of which the acted, executed the instrument. I certify under P TY OF PERJURY under t the State of Ca mia that the foregoing paragr and correct. WITNESS my nd and fal seal. d Signature of MAIL TAX i Quinta, County of Riverside, State of California, 12 to 16 of Maps, In the office of the county ss fore me JA� Robert Holllnshead `ce he with Susan t be the Susan Hollinshead 4#41111 t. loom laws of CaneMwlpn d I fN 44 is true 1► ° - coww M tMNt/Oe Cath. (This area for offlclal notary seal) AS DIRECTED ABOVE CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 6/26/2008 Green Sheet approvals are forwarded to the Buildinq & Safety Department directiv by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. S) Date:eloper: Tract N Addres (s): Lot No.(s): C Phone Number: The fo lowing, are tlfe requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: 1 ❖ CUSTOM HOMES: PROVIDE ITEMS #2, -3 AND ELOW ❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3, #4 (AS APPLICABLE) AND #6 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3 AND #5 BELOW ❖ WALLS: PROVIDE ITEMS #7 BELOW s• SIGNS: PROVIDE ITEMS #8. BELOW ❖ OTHER: PROVIDE ITEM #9 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold reen sheet ®aSoils submittal until- a ^Pad Elevation Certificate can be provided. Attachgeotecfinical cert�ficatio 'sof grading plan compli a including compaction reports from ai ed Engineer -Recently Tough' graded 'residential evelo ments which have a previously approv geotechnical certification are exempt from this requi ement. - Attach recorded final map or title information/gran deed sh proposed building locations are legal lots. eFinal maps may be viewed at the following websit http://www.fa-quinta.org/PlanCheck/m search.asp ��yL l i c%6� �L 4.Attach a completed <1 acre per lot or infill project ugitive Dust Control project information orm, PM10 plan & agreement or provide alternative & valid City appr ed PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments and 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 c tion number is required. V - Attach a copy of the precise grading plan to the Public Works Department showing buil ing o on s. AO flood zone developments will require an apec�floo in fde pnt��- fte L?%�-P6. Attach an approved rough or precise gradi g pl�n fort e bui ding location s for paev i v n i-c-ation or City plan set number if available. Plans may be viewed at the following website: PO http://www.la-guinta.org/PlanCheck/m search.aspx 7. Attach wall plan & related approved grading plan. v - �-- 8. Attach sign layout/plan & related precise grading/landscape plan. 56GL '' F-,;rn 0 6- 9. Attach supporting documentation for grease trap or special facility installations. I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the roject ay be relea for building permit issuance. Recommended by: Dated: Public Works Distribution: (_ Green Sheet to Building & Safety (_) Green Sheet to Planning Department clined for approval for reason(s) as follow(s), please correct and resubmit: Page 1 of 4 City of La Quinta, California PM 10 Fugitive Dust Control Project Information (< 1 acre/lot or Infill Project) (Form Updated & Effective 6-26-08) Project Information Project Contractor: r Project Phase (check one) R Construction ❑ Demolition Project Name: 14-16) It 5 CAOt E'-5iO4- C, Project Tract Number: 4-i' aAc;I" /3 b VO.®I C«- v�` � l�l�i 6 lZ91 Lot Numbers: Project Street Address: 'VS 2-;ci illi ki- de fVap-o-I Anticipated Start Date: 2, � 7Z 0% Anticipateo Cpletion Date: f 7 7OM9 Total Acres in Active Construction (< 1 acre per Lot): ,0 00 0 s ; 1 Project Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: ' rliUf_ r_Ssea 4o? -A Title: OA -"A6,t ,,- Company Name:2s1R. -�-: Mailing Address: 5-b �;-W wrysi4V44'ro�q 3-t- b -1 '2-Z-) City: &4 J LL,`_E a State: CA Zip Code: 11 Z Primary Phone #: o I-( Z -L Fax #: y---- 24 Hour Access/Emergency Phone#: tiJ 6 C 2, 4. Cell Phone #: 2& tD y e,;r- 2 g Email address: e PM 10 Certificate #: "i 0.2- y Y° Lt " ❖ Expanded PM10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. Page 2 of 4 Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill Project) Plan Updated 6-26-08 This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 4011 402, 201, 203 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ Visible dust emissions >20% opacity • Visible dust emissions that travel > 100 feet from the source (within site) • Visible dust emissions that cross any property line ❖ EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM10 certificate number prior to construction activity (training information may be obtained by contacting SCAQMD at (909) 396-2183). ❖ CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Plan must be kept on site. At least one short-term stabilization method must be used during off hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing activity. Control ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Approved signs shall be installed at a highly visible location. Please refer to the Coachella Valley Fugitive Dust Control Plan Handbook for Construction Signage Guidelines. ❖ TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of 15mph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. ❖ PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only. ❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works inspectors. No dirt on public or private roads. Track out shall be cleaned up within one (1) hour of incident and at the conclusion of each workday. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or grading permit. ❖ FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace PM10 fencing during the construction phase. ❖ EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also be applied during excavation or grading operations. Page 3of4 Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill Project) Plan Updated 6-26-08 ❖ DUMP TRUCKS: Open top dump trucks shall be wet down, moist and covered with a tarp prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. ❖. RECORD KEEPING: Fugitive Dust Control Plan records (i.e. self inspection records, records .of use of chemical suppressants, etc.) shall be maintained for 3 years by the Property Owner (or Authorized Representative). Property Owner shall notify the City and SCAQMD within 10 days of completion of project. City of La Quinta — Site Specific Construction Phase PM10 Agreement Agreement Updated 6-26-08 The signature of the property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. The property owner (or authorized representative): ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter upon the property for inspection and/or abatement purposes; and ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control r ny C ounty initiated abatement activities. Signature of Property Owner or Authorized Representative Date Printed Name of Property Owner or Authorized Representative Title of Property Owner or Representative C pany Name Phone Number Page 4 of 4 MEMORANDUM Of TO; Planning Department, Building and Safety Department FROM: Andrew J. Mogensen, Principal Planner,4" DATE: 05/18/2007 RE: Laguna De La Paz Development Standards Laguna De La Paz was approved in the County prior to City incorporation under Tract Map 13640. In order to have the development standards, the developer requested and was granted a variance (via a procedure no longer performed) on July 26, 1979 under County Variance case #1370. This approval essentially created setback standards different from the underlying RL zoning without a Specific Plan. The standards are as follows: Sides: One zero side yard and opposing 10 foot side yard Front: 10 foot setback Rear: 10 foot setback Exceptions: End lots (ex. Lot 1) can designate either side yard as a zero setback as long as the opposing side is 10 feet. A zero lot line must be maintained along locations with storm drains or easements (ex. Lots 6, 9). This item was also researched and verified by Wally Nesbit, Principal Planner, on June 29, 1999. xavier urbina 1193 marbella ct. January 26, 2009 architect grover beach, calif. (805) 481-1958 City of La Quinta Dept. of Building and Safety Project: Hollinshead Residence 48-239 Vista Del Nopal Re: Truss Calculation Review Gentlemen, A copy of the truss calculations has been submitted for review. The package consists of truss engineering calculations, truss configurations, and truss layout. The manufacturer is listed as Trussworks.of Palm Desert, Calif. The truss design and layout are in conformance with the structural design and intent of the structural drawings and calculations. Please feel free to call if you have any questions. Respectfully, CU I NTA BUILDING & SAFETY DEM X vier Urbina APPROVED Architect C13,333 FOR CON8TUCTVC3iN DATE= 0 DI BY a X'S -- d At64 $ g It E r K Certificate of Occupancy In•cwronnrn ,xx c�oF�9�� Building & Safety Department .. .This Certificate is issued pursuant to. the requirements. of Appendix Chapter 1 Section •110 of the � p 2007 California Building Code, certifying that, at the time of issuance, this structure was in compliance -with the provisions of the Building Code and the various ordinances of the City , regulating building construction and/or use.. ' - •�BUILDING ADDRESS: 48-239 VISTA DE NOPAL •�' . ' - Use classification: SINGLE FAMILY DWELLING .- _ r-` � •; - Building Permit No.: 08-1439 ,Occupancy Group:'R-3 Type of Construction: VN ,Land Use Zone: RL Sprinklers Installed: NO' _ Sprinklers Required: NO Occupant Load: 10 Owner of Building: ROBERT &SUSAN HOLLINS HEAD ' Address: 51 VARSITY RIDGE TERR, NW - ' City, ST, ZIP: CALGARY, CANADA, T3A 4Y2 • By: STEVE TRAXEL - Building Official Date: OCTOBER 9, 2009 �- POST IN A CONSPICUOUS PLACE E r K Certificate of Occupancy In•cwronnrn ,xx c�oF�9�� Building & Safety Department .. .This Certificate is issued pursuant to. the requirements. of Appendix Chapter 1 Section •110 of the � p 2007 California Building Code, certifying that, at the time of issuance, this structure was in compliance -with the provisions of the Building Code and the various ordinances of the City , regulating building construction and/or use.. ' - •�BUILDING ADDRESS: 48-239 VISTA DE NOPAL •�' . ' - Use classification: SINGLE FAMILY DWELLING .- _ r-` � •; - Building Permit No.: 08-1439 ,Occupancy Group:'R-3 Type of Construction: VN ,Land Use Zone: RL Sprinklers Installed: NO' _ Sprinklers Required: NO Occupant Load: 10 Owner of Building: ROBERT &SUSAN HOLLINS HEAD ' Address: 51 VARSITY RIDGE TERR, NW - ' City, ST, ZIP: CALGARY, CANADA, T3A 4Y2 • By: STEVE TRAXEL - Building Official Date: OCTOBER 9, 2009 �- POST k TITLE 24 REPORT Title 24 Report for: HOLLINSHEAD RESIDENCE 48239 Vista de Nopal La Quinta, CA 92253 Project Designer: -LENCH DESIGN STUDIO INC P O BOX 450 LA QUI NTA, CA. 92247-0450 760/564-1866 Report Prepared By: VERNA.LENCH Lench Design Studio, Inc. P.O. Box 450 La Quinta, CA 92247-0450 (760) 564-1866 1� Qumovc EP D AG BVL pp ON Job Number: F OB VL -.1441 003o2, neY Date: t, 2/27/2009 �� Of FlCf- The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: VL -1441 User Number: 5454 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _ 0i1 MHEAn RESIDENCE [jo Single Family ❑ Addition Total Conditioned Floor Area: 2/27/2009 Project Title 4-8939 Vosta_de Nortel I a Qtlinta ❑ Multi Family ❑ Existing + Add/Alt Date Project Address ft2 Building Front Orientation: (S) 180 deg Building Permit # I el1Cb_DpSiCJn Studio, Inr ft2 Fuel Type: (760) 564-1866 Natural Gas Documentation Author 2,189 ft2 Telephone Plan Check/Date �LleravPro Average Ceiling Height: 11.3 15 Area: Field Check/Date CompliUce Method Number of Dwelling Units: 1.00 Climate Zone Ratio: TDV Standard Proposed Compliance kBtu/sf- r) Design Design Margin Vent Space Heating 1.67 1.97 -0.30 Hgt. Space Cooling 65.11 66.29 -1.18 038 Conditioned -Setback Fans 9.25 9.41 -0.16 1 35 13,5510 Domestic Hot Water 10.97 3.15 7.82 Pumps 0.00 0.25 -0.25 Totals 87.00 81.06 5.94 Pe 6.8% Building Type: [jo Single Family ❑ Addition Total Conditioned Floor Area: 2,189 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S) 180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,189 ft2 Fenestration: Average Ceiling Height: 11.3 ft Area: 493 ft2 Avg. U: 0.39 Number of Dwelling Units: 1.00 Ratio: 22.5% Avg. SHGC: 0.32 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC - Zone 1 R3R 11 145 038 Conditioned -Setback -2 -n/a HVAC -7nne 2 1 35 13,5510 062 Conditioned Sethack _n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. AZ_ m. Tilt Roof- Wood R319 _0 n25 R-119 R_() n 1R0 0 Wall Wood 62 _0079_ -R -13_-R-45_ 1F10_ 9A, Wall Wood 170 -0_074 R-1-4 R-4 `i _270-9Il A/all blood- 34 _Q 0.74_ R-1.3_ _R -4_S_ -225_ 9.0 Wall Wnod 93 0 074 R_13 R-4 5 270 gQ Wall Wood _3.8_ 0074 4-13_ -R-4 5 V; An Wall Wnod112 _0_074_ R_13 R-45 0_ s0 Wall Wnnd RR 0074 R_13 R-4 5 45_An Wall Wood 30 _0_0.74_ -$-.3_ -R-4 5_ n_ 9.Q Wall Wood 106 0 074 R_13 R_4 5 x90 Rnnf Wood- 1 333_ -2025 R-38 X0_0__]80 0 W,g11 Wood- 95 _0.074_ _R-1.3_ -4 5_ x.80_ 9.0 Wall_ Load_ 169 0074 -R-13_-R45_ 9.0 9.0 Wall Wond 60 _2074 R -13_ R-4_5_ 270 90 Wall Wood- 26 0074 -R-1.3_ -R-4-.5_ -225_ 9.0 Wall Wood 20 _0074 R -1.$_-L-4.5_-27_0 9.0 w la_l- Wood 95 -0102_ R_13 R-0 n 180 gn wall Wppd 23 X02 R_13 R-0 0 9n gn Wall Wond 125 _0102 R_13 R -n n 1Rn 90 Wall Wood 453 0 074 R_13 R-4 5 9r) 90 Wall Wood_ 52 _2074 R-13 RA 5 �_ 90 Wall wood_ 0 0 074 13-13 -4 5_ 5 9.0 Gains Condition Y / N Status JA IV Reference Location / Comments n1 -A18 70NF 1 09-A3 ZONE 1 n9 -A3 ZONE 1 09-A3 70NF 1 09-A3 ZONE 1 09-A3 ZONE 1 09-A3 70NF 1 09-A3 ZONE 1 09-A3 ZONE 1 09-A3 ZONE 1 01-AlR ZONE 7 09=A3 ZONE 2 99-A3 ZONE 2 09-A3 70NF 2 09-A3 70NF 2 MAI 70NF 2 09-A3 70NF 2 n9_A3 MNF 2 09-A3 70NF 2 09-A3 70NF 2 09-A3 ZONF 2 09-A3 70NF 2 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:3 of 20 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R HOLLINSHEAD RESIDENCE 2/27/2009 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U-Factorl SHGC2 Am. Tilt Stat. Glazing Type Location/ Comments 1 Window Front (S) 65 017 NFRC O I NFRC -180 -90_ New IWC 5300 Vinyl/Low-F 70NE 1 2 Window Front (S) 11.8 0.370 NFRC 0_32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 3 Window Front (S) 6.5 0.370 NFRC 0_32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 4 Window Left (W) 17.5 0.370 NFRC 0.32 NFRC 270 90 New IWC 5300 Vinyl/Low-E ZONE 1 5 Window Front (SW) 24.0 0.370 NFRC 0_32 NFRC 225 90 New IWC 5300 Vinyl/Low-E ZONE 1 6 Window Front (SW) 9.0 0.370 NFRC 0_32 NFRC 225 90 New IWC 5300 Vinyl/Low-E ZONE 1 L Window Left (NW) 19.5 37O NFRC_0 32 NFRC X15_ _al New IWC 5300 Vinyl/Low-E ZONE 1 8 Window Left (NW) 9.0 0.370 NFRC 0.32 NFRC 315 90 New IWC 5300 Vinyl/Low-E ZONE 1 3 _M Window Rear (N) _2_9 -3 -0-M NFRC 0_.32 NFRC 0 _90 New IWC 530.0 Vinyl/Low-E Window ReA (Ll) 13.5 Q 3D NFRC-- 32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 ZONE 1 11 Window Rear (NE) 19.5 0.37 NFRC0 32 NFRC 45 90 New IWC 5300 Vinyl/Low-E ZONE 1 12 Window Rear (NE) 9.0 0.370 NFRC 0_32 NFRC 45 90 New IWC 5300 Vinyl/Low-E ZONE 1 Aa Window Rear (N) 20.0 0.37 NFRC-o-32 _NFRC 0 _9.Q New IWC 5300 Vinyl/Low-E ZONE 1 14 Window Rear (N) 33.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 15 Window Rear (N) 33.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 16 Window Rear (N) 33.0 0.370 NFRC 0_32 NFRC 0 90 New JWC 5300 Vinyl/Low-E ZONE 1 17 Skylight Front (S) 4.0 0.590 NFRC 0_38 NFRC 180 0 New Slight - Dual Glaze ZONE 2 18 Skylight Front (S) 4.0 0.590 NFRC 0_38 NFRC 180 0 New Slight - Dual Glaze ZONE 2 19 skyfight Front (,S�_ 0 Q590 NFRC 038 NFRC _18.0 0 New Skylight - Dual Glaze ZONE 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. 15 Bug Screen INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 1.5 3.0 12.0 0.1 12.0 12.0 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 6.5 5.0 6.0 0.1 6.0 6.0 15 Bug Screen 0.76 6.5 5.0 6.0 0.1 6.0 6.0 16 Bug Screen 0.76 6.5 5.0 6.0 0.1 6.0 6.0 17 None 1.00 18 None 1.00 19 None 1.00 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 73 None No Insulation 26-A1 New ZONE 1 Slab Perimeter 24 None No Insulation 26-A1 New ZONE 2 Slab Perimeter 110 None No Insulation 26-A1 New ZONE 2 Run Initiation Time: 02/27/09 07:10:24 Run Code: 1235747424 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:4 of 20 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R HOLLINSHEAD RESIDENCE 2/27/2009 Project Title Date FENESTRATION SURFACES # Type Area U-Factorl SHGC2 True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments 2Q Skylight Front (4) 4.0 _0 58DNEBC n 38 NFRC 1A0 -0_ New Skylight - Bunt ('laze SNE 2 21 Skylight Front (S) 0.6 0.590 NFRC 0_38 NFRC 180 0 New Skylight - Dual Glaze ZONE 2 22 Skylight Front (S) 0.6 0.590 NFRC 0_38 NFRC 180 0 New Skylight - Dual Glaze ZONE 2 23 Skylight Front (S) 0.6 0.590 NFRC 0_38 NFRC 180 0 New Skylight - Dual Glaze ZONE 2 24 Window Front (S) 40.0 0.370 NFRC 0_32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 2 25 Window Right (E) 24.0 0.370 NFRC 0_32 NFRC 90 90 New IWC 5300 Vinyl/Low-E ZONE 2 28 Window Front (,SW) 24.0 0.370 NFRC _U2 NFRC 225 _9Q New IWC 5300 Vinyl/Low-E 70NE 2 27 Window Right (E) 7.5 0.700 NFRC 0.38 NFRC 90 90 New Glass Block ZONE 2 28 Window Right (Fa 5.0 0.700 NFRC -0-M JNFRC 90- 90 New Glass Block ZONE 2 2Q Window Right (E) 7.5 0.70 NFRC� 38 JCC -9.0 -9Q New Glass Block ZONE 2 2Q Window Rear (N) 33.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 2 31 Window Left (NW) 40.0 0.370 NFRC 0_32 NFRC 315 90 New IWC 5300 Vinyl/Low-E ZONE 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt. 20. None 1.00 21 None 1.00 22 None 1.00 23 None 1.00 24 Bug Screen 0.76 ?5 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Tvoe (sf) (in.) Car). Cond. R -Val. JA IV Reference Status Comments Run Initiation Time: 02127/09 07:10:24 Run Code: 1235747424 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:5 of 20 Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 02127/09 07:10:24 Run Code: 1235747424 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:5 of 20 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R HOLLINSHEAD RESIDENCE 2/27/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC - Zone 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC - Zone 2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC - Zone 1 Ducted Ducted Attic 4.2 New Yes HVAC - Zone 2 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Laars JVH075LD(I/L) Instant Gas Recirc/Time+Temp 1 75,000 0 New 0.82 750 n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or O7r �Jusiness, Pro os�Code) Name: p(.�/a Title/Firm: LENCH DESIGN STUDIO INC Address: P O BOX 450 Telephone: (sZna e) (date) Ement Agency Name: Title/Firm: Address: Telephone: (date) Documentation Author Name: VERNA LENCH Title/Firm: Lench Design Studio, Inc. Address: . P.O. Box 450 La Quinta CA 92247-0450 T, ephRe: 760 564-X6_0 a� o (signature) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R HOLLINSHEAD RESIDENCE 2/27/2009 Project Title - Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adenuacv of the iustification, and may refect a buildinq or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- Plan I Field approvea ntKb proviaer using ctu approvea testing anaior vermcation metnoas ana must oe reportea on the cr-art installation certificate. Plan Field The HVAC System "HVAC - Zone 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC - Zone 1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC - Zone 2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC - Zone 2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:7 of 20 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application- documentation. N/A DESIGNER MENT Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor inmetal frame ceiling. ❑ 5 ❑ § 150(b): Loose fill insulation manufacturer's labeled R' -Value: ❑ ❑X ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). {§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ 0 ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a: closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ 0 ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply.with §151,meets requirements specified in the ACM Residential Manual: ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption, rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑X ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, -and Infiltration/Exfiltration Controls.' 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain _ ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ 0 ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation., 1. Storage gas water heaters rated with an Energy factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater: A 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. , 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines)', piping insulated between heating source and El Q ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture; equipment maintenance, ❑ ❑X ❑ . and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑X ❑ EnergyPro 4.3 by EnergySoft User Number: 5454 Jot Number: VL -1441. Page:8 of 20 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ 0 ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑X ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑X ❑ reductions in the cross-sectional area of the ducts. ❑ 0 ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ Lighting Measures ❑ 2 ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ 0 ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ 0 ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, ❑ 0 ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ 0 ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ 0 ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑X ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ 0 ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1' 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ 0 ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)B: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:9 of 20 Residential Kitchen Lighting Worksheet WS -5R HOLLINSHEAD RESIDENCE 2/27/2009 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 10w Compact Fluorescent 2D Elec Yes X No 13.0 x 6 78 or (11) 22w Fluorescent Circline Rapid Start Yes X No 27.0 x 8 = 216 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No. "x = or Yes No x- = or Yes No x _ or Yes No x _ or Yes No x = or Yes No x= or Yes No x _ or -Yes No x = or Yes No x - or Yes No x _ or Yes No x = or Yes No x = or Yes No -x= or Yes 'No, x _ or Total A: 294 B: 0 y COMPLIES IF A z B YES ® NO ❑ HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HOLLINSHEAD RESIDENCE 2/27/2009 SYSTEM NAME FLOOR AREA HVAC - Zone 1 838 Number of Systems 1 Heating System Output per System 54,000 Total Output (Btuh) 54,000 Output (Btuh/sgft) 64.4 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 41.8 Total Output (sgft/Ton) 287.3 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.43 Airflow (cfm/Ton) 411.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 69.0 of Outside Air 0 cfm Supply Fan 1200 cfm 69.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensib 13,187 I CFM I Sensible 1,166 18,474 1,575 307 13,187 0 2,220 1,217 0 0 0 0 0 0 0 0 0 2,220 1,217 22,9141 1,5751 15 622 Bryant 550AN036-E/31 1 JAV036070 23,449 8,769 54,000 Total Adjusted System Output 23,aa9 8,769 5a,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.0 of n 111.3 of Heating Coil �% Return Air Ducts 'I Supply Air Ducts 110.4 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 79.7/66.8OF 79.7/66.8OF 61.4/60.3OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 63.1 / 60.9 of 1200 cfm 54.4% R.H. ROOMS 79.7/66.8 of 78.0 / 66.2 of o,.a. .... A:. n..,.&.. E I EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:11 of 20 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HOLLINSHEAD RESIDENCE 2/27/2009 SYSTEM NAME FLOOR AREA HVAC - Zone 2 1,351 26.0 of 68.7 of Outside Air 0 0 cfm Supply Fan 1200 cfm 68.7 of 11.0 / 77.6 of >---;ll Outside Air 0 cfm 79.6/67.0 of 68.7 of M PSYCHROMETRI TEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 1,092 17,239 2,049 429 18,090 0 2,071 1,670 0 0 0 0 0 0 0 0 0 2,071 1,670 21,382T 2 049 F7721 430 Bryant 550AN036-E/31 1 JAV036070 23,091 9,234 54,000 Total Adjusted System Output 23,091 9,234 54,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 111.0 OF Heating Coil h Return Air Ducts 4 79.6 / 67.0 OF 79.6 / 67.0 OF 61.5 / 60.5 OF -�,T� Supply Fan 1200 cfm Cooling Coil h Return Air Ducts"I 16 Supply Air Ducts 109.7 of ROOMS. 70.0 of Supply Air Ducts 63.2 / 61.1 of 55.2% R.H. ROOMS 78.0 / 66.5 of EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page: 12 of 20 ROOM LOAD SUMMARY PROJECT NAME HOLLINSHEAD RESIDENCE DATE 2/27/2009 SYSTEM NAME HVAC - Zone 1 FLOOR AREA 838 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME - Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 1 ZONE .1 1 1,166 18,474 1,575 1,166 18,474 1,575 307 13,187 PAGE TOTAL 1 1,166 18,474 1,575 307 13,187 TOTAL 1 1,166 18,474 1,575 307 13,187 EnergyPro By EnergySoft User Number: User Job Number: VL -1441 Page:13 of 20 ROOM LOAD SUMMARY PROJECT NAME HOLLINSHEAD RESIDENCE DATE 2/27/2009 SYSTEM NAME HVAC - Zone 2 FLOOR AREA 1,351 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 2 ZONE 2 1 1,092 17,239 2,049 1,092 17,239 2,049 429 18,090 �i PAGE TOTAL 1 1,092 17,239 2,049 429 18,090 TOTAL 1 1,092 17,239 2,049 429 18,090 EnergyPro By EnergySoft User Number: User I Job Number: VL -1441 Page: 14 of 20 ROOM HEATING PEAK LOADS Project Title Date HOLLINSHEAD RESIDENCE 2/27/2009 Room Information Desi n Conditions Room Name ZONE 1 Time of Peak Jan 12 am Floor Area 838 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value nT of Btu/hr ER -11 3 Wall w1l " FPS Interior IWC 5300 Vin I/Low-E IW(' 510171 Vinyl/l nw-F IWC 5300 Vin I/Low-E R-1 3 Wall w/1 " EPS Intermor IWC 5300 Vin I/Low-E R-13 Wall w/1" FPS Interior IWC 5300 Vin I/Low-E IWC 5100 Vinyl/l nw-F R-13 Wall w/1" EPS Interior R-13 Wall w/ " EPS Interior IWC 5300 Vin I/Low-E 1W(' S100 Vonyl/I nw-F Mr. 5300 Vinyl/I nW-F R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior IWC 5300 Vin I/Low-E 838.0 perimeter = 73.3 62.2 6.5 11.8 6.5 169.6 17.5 33.7 24.0 9.0 93.0 38.2 195 9.0 112.2 3 13.5 38.2 19.5 9.0 30.0 20.0 106.0 33.0 33.0 33.0 X X X X X X x X X X X X X x X X x X X X X X X X X X X X x X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = 922 44 2,354 44 203 44 106 44 192 44 106 44 554 44 285 44 110 44 391 44=147 44 304 44 125 44= 317 44 147 44 367 44=477 44 22Q 44 125 44 317 44 147 44 98 44 326 44= 3 44 5.3 44 537 44 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10,298 Infiltration: 1 1.00 X 1.064 X 838 X 13.30 X 0.332 / 60] X 44 = 2 gg0 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,187 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page: 15 of 20 ROOM HEATING PEAK LOADS Project Title Date HOLLINSHEAD RESIDENCE 2/27/2009 Room Information Desi n Conditions Room Name ZONE 2 Time of Peak Jan 12 am Floor Area 1,351 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value nT of Btu/hr on n 1 It - vuai v10cv Skylight Sk li ht - Dual Glaze Skylight - Dual Gla7a Sk li ht - Dual Glaze Skylight - Dual Glaze Skylight - Dual Glaze Slab -On -Grade lnterin IWC 5300 Vin I/Low-E R-13 Wall w/1" EPS Interior IWC 5300 Vin I/Low-E R-11 Wall w/1" FPS Intprenr R-1 3 Wall w/1 " FPS Intpr4or IWC 5'400 Viny'll nw-F R-1 3 Wall w/1 " EPS Intermor R-13 Wall R-13 Wall w/1" EPS Interior Glass Block Glass Block 6-11 to/.II —11" FPC W—i- 1 333.3 4.0 4.0 4.0 4.0 0.6 0.6 0.6 perimeter = 110.1 95.0 40.0 169.0 24.0 60.0 26.0 240 20.0 95.0 23.0 125.0 453.0 7.5 5.0 7.5 52.0 33.0 40.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = 1,467 44 104 44 104 44 104 44 104 44 14 44 14 44 14 44 781 44 3,536 44=311 44 651 44 553 44= 391 44 1 CIS 44 85 44 3511 44 65 44 426 44 103 44 '961 44 1,482 44 231 44 154 44 231 44 170 44 537 44=651 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 431 Infiltration: I1.00 X 1.064 X 1 351 X 10.00 X 0.442 / 60] X 44 = 4 659 chedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 18,090 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page: 16 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date HOLLINSHEAD RESIDENCE 12/27/2009 Room Information Desi n Conditions Room Name: ZONE 1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 838 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F ue surraces R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior Orientation Area X X X X X X X X x x X X U -Factor X X X X X X X X X x X X CLTD 1 = = = = = = = = = = = Btu/hr 838.0 0.0250 77.0 1,613 62.2 0.0743 38.0 176 169.6 0.0743 55.0 693 33.7 0.0743 52.0 130 93.0 0.0743 55.0 380 38.2 0.0743 48.1 136 248.2 0.0743 31.0 572 38.2 0.0743 34.0 96 64.4 NW 0.0 23.2 19.5 52.5 NW 0.0 23.2 9.0 52.5 N 0.0 23.2 29.3 23. Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 1066 FO Window 5626 arch FO Window 1066 FO Window 5036 XO Window 3080 FR DR Window 3030 FO Window 3066 FO Window 3030 FO Window 4666 XO Window 4630 FO Page I otal 1 3,7971 Orientation Shaded Area x x X X x X X x x x X GLF + + + + + + + + + + + Unshaded Area X X X X X X X x X X X Page GLF = = = = = = = = _ S 6.5 23.2 0.0 30.3 S 0.0 23.2 11.8 30.3 S 0.0 23.2 6.5 30.3 W 0.0 23.2 17.5 70.7 SW 0.0 23.2 24.0 64.4 SW 0.0 23.2 9.0 64.4 NW 0.0 23.2 19.5 52.5 NW 0.0 23.2 9.0 52.5 N 0.0 23.2 29.3 23. N 0.0 23.2 13.5 23.2 Total Btu/hr Internal Gain Btu/hr Occu ants 4 X Occupants x 230 Btuh/oCC. = 920 E ui ment x Dwelling Units X 1,2001 Watts/sqft = 1 200 Infiltration: 1.064 X 1.16 X 53.10 x = 2.2-4-11 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,474 Latent Gain Btu/hr Occupants x Occupants X 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.16 x 53.10 x 0.00263 = 775 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,575 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page:17 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date HOLLINSHEAD RESIDENCE 2/27/2009 Room Information Desi n Conditions Room Name: ZONE 1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 838 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F vNayuc mut 10L wa Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window X X X X X X X X X X X X Window X X X X X X X X X X X X Window 2680 FR DR Window 5066 XO Window 5066 XO Window 5066 XO 19.5 35.1 NE 0.0 23.2 9.0 35.1 N 0.0 23.2 20.0 23.2 N 0.0 23.2 33.0 23.2 N 0.0 23.2 33.0 23.2 N Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window 3066 FO Window 3030 FO Window 2680 FR DR Window 5066 XO Window 5066 XO Window 5066 XO 19.5 35.1 NE 0.0 23.2 9.0 35.1 N 0.0 23.2 Nage I otal Orientation Shaded Area X X X X X X X X X X:::::] X GLF + + + + + + + + + + + Unshaded Area X X X X X X X X X X X GLF NE 0.0 23.2 19.5 35.1 NE 0.0 23.2 9.0 35.1 N 0.0 23.2 20.0 23.2 N 0.0 23.2 33.0 23.2 N 0.0 23.2 33.0 23.2 N 0.0 23.2 33.0 23.2 Page Total Btu/hr 1 Btu/hr Internal Gain Btu/hr Occu ants 4 X Occupants X 230 Btuh/oCC. = 920 E ui ment FX Dwelling Units X 1 1 200 Watts/Sgft = 1.200 Infiltration: 1.064 X 1.16 X 53.10 X 34 = 2.2331 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,474 Latent Gain Btu/hr Occu ants X Occupants -X 200 Btuh/oCC. = 800 Infiltration: 4771 X 1.16 X 53.10 X 0.00263 = 775 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,575 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page: 18 of 20 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date HOLLINSHEAD RESIDENCE 12/27/2009 Room Information Desi n Conditions Room Name: ZONE 2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,351 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F opaque surraces R-38 Roof Attic R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall w/1" EPS Interior R-13 Wall R-13 Wall Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X x x S 1,333.3 0.0250 S 95.0 0.0743 E 169.0 0.0743 W 60.0 0.0743 SW 26.0 0.0743 W 20.0 0.0743 (S) 95.0 0.1020 (E) 23.0 0.1020 S 125.0 0.1020 26.4+ 0.6X 77.8= (Sky) 0.0x 26.4+ 0.6X 77.8= (Sky) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Skylight 2'X2' Skylight 2'X 2' Skylight 2'X2' Skylight 2'X2' Sk li ht 10" Dia Skylight 10" Dia Skylight 10" Dia Window 2680 (2) FR DR Window 4060 XO Window 4060 XO CLTD 1 Btu/hr c 1,867 184 415 147 60 49 252 77 332 Page Total 1 3,3821 Orientation Shaded Area x x x19.3 X GLF + + + + Unshaded Area X X x X Page GLF = = (Sky) 0.0X 26.4+ 4.0X 77.8= (Sky) 0.0x 26.4+ 4.0X 77.8= (Sky) 0.0x 26.4+ 4.0X 77.8= (Sky) 0.0X 26.4+ 4.0X 77.8= Sk 0.0X 26.4+ 0.6X 77.8= (Sky) 0.0x 26.4+ 0.6X 77.8= (Sky) 0.0x 26.4+ 0.6X 77.8= S 0.0 19.3 40.0 19.3 E 0.0 19.3 24.0 38. SW 0.0 24.0 Total Btu/hr Internal Gain Btu/hr Occu ants B4 X Occupants X 230 Btuh/occ. = 920 E ui ment 1 x Dwelling Units X 1,600 Wafts/sqft = 1.6001 Infiltration: 1.064 X 1.16 X 85 60 X 3.6001 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,239 Latent Gain Btu/hr Occu ants 0 x Occupants x 200 Btuh/OCC. = 800 Infiltration: 4 771 X 1.16 X 85.60 X 0.00263 = 1.2491 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,049 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page: 19 of 20 O RESIDENTIAL ROOM COOLING LOAD SUMMARY Room Information Desi n Conditions Room Name: ZONE 2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,351 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F upaque burraces IR -1 3 Wall w/1" EPS Interior Orientation Area U -Factor CLTD 1 E 453.0 X 0.0743 X 33.0 N 52.0 X 0.0743 X 23.0 X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration rage I otal Btu/hr = 1,111 89 1 200 Orientation Btu/hr Shaded Area X X X X X X X x x x GLF + + + + + + + + + + Unshaded Area X X X X X X X X X X Page GLF = = = = = = = = = = Btu/hr E 0.0 28.1 7.5 50.7 380 E 0.0 28.1 5.0 50.7 253 E 0.0x 28.1+ 7.5X 50.7= 380 N 0.0 19.3 33.0 19.3 636 NW 0.0 19.3 40.0 29.6 1,183 Total 2.8321 { Internal Gain Btu/hr 1 Occu ants 4 X Occupants X 230 Btuh/occ. = 920 E ui ment X Dwelling Units X 1,600] Watts/sqft = I 1.6001 Infiltration: 1.064 X 1.16 X 8 .60 X 34 = 3 600 j Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,239 Latent Gain Btu/hr Occupants ----7 0 X Occupants x 2001 Btuh/occ. E800 Infiltration: 4 771 X 1.16 X 85.60 X 1 0.00263 1 1.2491 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,049 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1441 Page: 20 of 20