Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
AR-14-707
78-495 CALL TAM ICO LA QUINTA, CALIFORNIA 92.253 Application Number: AR -14-707 i `&tr4'lwQ"- COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Property Address: 48255 VISTA DE NOPAL APN: 6461/0025 Application Description: CONVERT PATIO TO INTERIOR LIVING SPACE Property Zoning: Application Valuation: $0.00 Applicant: IF SUTTON REMODELING SPECIALISTS 41-905 BROADWALK P 12 201A . PALM DESERT, CA 92211 Y VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/12/2014 Owner: ~ CHEZIK & HENNESSEY 9200 NORTHWEST PRAIRIE VIEW RD KANSAS CITY, MO 64153 Contractor: SUTTON REMODELING SPECIALISTS 41-905 BROADWALK PALM DESERT, CA 92211 CITY OF LA OUINTA COMMUNITY DEVELOPMENT DEPARTMENT (760)674-9000 Llc. No.::LIC-0104555 1 --------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: :LIC -0104555 1,�/fj'Yl n_ Cate: Contractor�:�i6�U// OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. I. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: +' r Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance oft aork for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code,, I shall forthwith comply -with those provisions. cc Date" �Z 4 i Applicant:: IWiiflfS�li' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES.UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property /for inspection purposes. Date: —1 Z �'f Signature (Applicant or Agent A. 1 1 • 1 • DESCRIPTION QTY ; AMOUNT "'� r PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $61.49 $0.00 PAID BY-'' ' P # ;� �Y �r� METHOD ;k ' ;"RECEIPT # ' CHECK # CLTD BY DESCRIRTION� ,�' r `. ACCOUNT t..4'* QTY= ° `R $"AMOUNT .f� PAID {PAID DATE:; ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.16 $0.00 z r` PAIDBY ..� 1,T w.} `+ CHECK#a. CLTDBYR- DESCRIPTION:` rt a4 -ACCOUNT` CO xm yQTY bPAMOUNT� ,�; PAID PAID.DATE; ADDITION, FIRST 100 SF 101-0000-42400 0 $120.12 $0.00 L g > iBY 2 � PAIDD . � ; £{ METHOD ; �... � -a _. _ �' ' RECEIPT W CHECK # CLTD BY � ` ti ri. .DESCRIPTION t r. g$ «' A ACCOUNT , '.QTY s *+ x+ x u I►MOUNT, - PAID ' Me. PAID: DATE ADDITION, FIRST 100 SF PC. 101-0000-42600 0 $168.74 $0.00 (PAID BY : a .,F� F METHOD r a�` `t x 'l. ed. Y P $ _ ' REC14f _CHECK # r' ,,y x- c CLTD BY Total Paid forADDITION: $367.51 $0.00 ` } DESCRIPTION&, ?L;ACCOUNT , s. QTY ;�a fiAMOUNT 3TgPAID, s:�* PAID DATE: BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 s«* PAID BY T 4 <METHOD,"; 1 RECEIPT# $ CHECK# 424' �+d CLTD BYa Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION - . A•CCOLINT Ith i "1 QTY `�F %AMOUNT` w.�a£ PAID # 3 c PAID;DATE- HOURLY PLAN CHECK - YES 101-0000-42600 0.75 $52.50 $0.00 `1g,F r x€�� PAID'BY �� � 'tA zRi,METHOD r � r xRECEIPTr#g k { CHECK # z , . Ell CLTD BY Total Paid forCITY STAFF - PER HOUR: $52.50 $0.00 Y aDESCRIPTION�`mj �,,ACCOUNT :"gTY` AMOUNT-F,+--zw'aPAID'ra Yqz PAID DATE FIXTURES, FIRST 20 101-0000-42403. 9 $214.47 $0.00 BY METHOD" � IPT n. f# r 4! CHECK Y,PAID CLTD B <DESCRIPTION `sd * , �* -ACCOUNTS.rtes AMOUNTS.; PAIkD 2.1 �.. PAID DATE. FIXTURES, FIRST 20 PC 101-0000-42600 9 $214.47 $0.00 t -.. . ... F, 4.. }:,.+. Y--... ..F 9:.,. .' .> METHOD-j-s.w' }`' w:w ". . FY,:.• s.t — :.fir e:> f R : f ECEIPT.,# sSCHECK #+; CLTD BYE .Total Paid for ELECTRICAL: $428.94 $0.00 T' %✓ y, da zDESCRIPTION ' �s�€°fr ACCOUNT a QTY ✓k AMOUNTAg ,Y'a. rPAID , ' PAID DATE' HOURLY PLAN CHECK 10160003428200 $105.00 �, ,.; METHOD r ry ' ;::RECEIPT # j'>> �t . > a " CHECK# CLTD BY�w' f Total Paid forHOURLY PLAN CHECK: $105.00 :x L Yr.. Fa. ... 3 r-:,• i ,DESCRIPTION't' E=?� 'i L w rK:. '+F«.-x}w,:N�; h-�'. E' Y r+x. .� .� ACCO CINTu }' ..'• _FS-, f9 .-e- -.:c a ",R e:,t. ;: QTY z -x-.7 -x, rx - �t-, UNT -� AMOs . ?kr. ... .r..< r:.:cy .re.:x. s s*PID+x i .a;.,_ A< s.':,�s }PAID DATE' S APPLIANCE REPAIR/ALTERATION � 101-0000-42402 0 $11.92 $0.00 ''9,Y•Qb S.q''�iK..AT3£@% % ;,,5:'{!T i f. +'y..1' 2tx�,iX3 .�1TE s , PAID.BY ,., �ra� ., p . �wX 4$WF� X_'�' yam. v,,e'•E 0�{ "F?St�,Y < METHOD : h_" RECEIPT # : .. �Zt.. c r ,�' ' CHECK # 41�r,, d CLTD BY. . , .DESCRIRTIONsf .....»_:»�...,b•,z ;a'"ACCOUNT ;� t.,C�., n Q TY' ,'Ew = AINIOUNT� f r , F _PAID` PAID'DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.77 $0.00 PAID BY ,...:,`ry ' METHODF? RECEIPT # A CHECK #2 f ` CLTD BY Total Paid forMECHANICAL: $16.69 $0.00 ti a=' ti 'DESCRIP;TION S,', `. N, ACCOUNTP� �� QTY$ � �>AMOUNT� � '� PAIDr �` _. n2PAID'DATE- SMI - RESIDENTIAL 101-0000-20308 0 $1.95 $0.00 PAID BY , eu '#.`. ,b,g �a METHOD �+ ��.61;RECEIPT# 's{i Y2F..;g ?.y h f..: t FS'i a CHECK#:. # i CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMt $1.95 $0.00 •0• Description: CONVERT PATIO TO INTERIOR LIVING SPACE Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED Applied: 5/28/2014 Approved: 9/10/2014 JJO Parcel No: 646110025 Site Address: 48255 VISTA DE NOPALLA QUINTA,CA 92253 Subdivision: Block: Lot: Issued: Lot Scl Ft: Building Scl Ft: Zoning: Finaled: Valuation:. $15,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: No. Stories: No. Unites: Details: CONVERT EXISTING PATIO TO A/C SPACE 139 SQ. FT. 105 i k ......; INANCIAL INFORMATION ..,n,,, Printed: Friday, September 12, 2014 8:47:16 AM 1 of 3 SYSTEMS 71777 V 9 , ACCOUNT MOUNV-42 AIUVAT�,� Ac r1r. T HEMETHOD,1; a ADDITION, EA - 101-0006-42400 0. $61.49 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 --$17.16 $0. . 00 ADDITIONAL 500 SF PC • ADDITION. , FIRST 100 SF 101-00.00-42400 0 $1.20.12 $0.00, ADDITION, FIRST 100 SF 101-0000-42600 0 .$168.74 $0.00 PC- - Total Paid forADDITION: $367:51 $0.00 BSAS SB1473 FEE 101-0000-20306, 0 $1!00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0 . .00, BSA: HOURLY PLAN CHECK - _ 101-0000-42600 F0,75 $52.50 $0.00 Y ES Total Paid forCITY STAFF - PER HOUR: $52.50 $0.00 FIXTURES, FIRST 20 101-0000-42403 9 $214.47 $0.00 FIXTURES, FIRST 20 PC 101-000042600 9 $214.47 $0.00 Total Paid for ELECTRICAL: $428:94 $0.00 HOURLY PLAN CHECK. 10160003428200 $105.00 Total Paid forHOURLY PLAN CHECK: $105.00 APPLIANCE 101-0000-42402 0 $11.92 $0.00 REPAIR/ALTERATION APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.77 $0.00 Total Paid forMECHANICAL: $16.69 $0.00 SMI RESIDENTIAL 101-0000-20308 0 $1.95 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $1.95 $0.00 .......... .... . ......... ....... ....TALS ".$973.59 -1 ............. .......... . . . 1.11 . ......... . ... . .... . TO$0.00.01 ......... .. ........ .. . .. .... .......... ............. .. . ........ .. . . .. ....... .. - Printed: Friday, September 12, 2014 8:47:16 AM .2 of 3 CRWYSTEMS ,IN'SPECT16% PARENT, PROJECTS ..... Printed: Friday, September 12, 2014 8:47:16 AM 3 of 3 srsrrnns S ��Zg 5l�c-,� �oanq 1� b • il• t�} ejas �-a � du.Q— 9iB. 1 City Of La QUIn to • Building 8z Safety Aivision Box 1504,78-495 Calle Tampico _ 4.Qllinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit #P.O. .V,qo*l l� Project Address: 48255 Vista De Nopal. Owner'sxame: Sharon Chezik / Bobby &Laura Hennesey A. P. Number. Address: 9200 Northwest Prairie View Rd. Legal Description: City, sP, zip: Kansas City; MO 64153 contractor. Sutton Remodeling Specialists Telephone: 913.706.5993 ... 33s Address: 41905 Boardwalk Suite #G Project Description: Turning'the covered patio area into City, ST, zip: Palm Desert, CA 92211 a room addition to the living space of the home. Telephone: 760.674.9000 State Lic. #: 6=837914City Lic. #; Arch, Engr., Designer. Charles D. Garland Aaaress: 74991 Joni Dr. Suite #9 City., ST, zip: Palm Desert, CA 92260 Telephone: 760.340:3528 ' =rz State Lic. #: C-11991 �. =` :::' : n V Name of Contact Person: Paul "Belly" Sutton Construction Type: V -B Occupancy: Project type (circle one): XX( Add'a XU W4M I Sq. Ft.: 1973 #Stories: 1 #Unitp:2 Telephone* of Contact Person: 760.674.9000 Estimated Value of Project: $15,000.00. APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd RSad TRACMG PERMIT FEES Plan Sets Plan Check submitte S O Item Amount Structural Calcs. 37:7Reviewed, ready [ r corrections 11 Plan Check Deposit. . Truss Calcs. Called Contact jib Plan Check Balance Title 24 Calci. Plans picked up (��� ��gg Construction Flood plain plan Plans resubmitted.. Ti161 Mecharilcal Grading plan 2'! Review, ready for correctioslissue Q (0 Electrical Subcontactor List Called Contact Person b I Plumbing Grant Deed Plans picked up S.M.h H.O.A. Approval for Plans resubmitted Grading IN txousE:- 34 Review', ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Tota mit Fees ��Zg 5l�c-,� �oanq 1� b • il• t�} ejas �-a � du.Q— 9iB. 1 4 Community Development Dept. Building Division 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7125 voice — (760) 777-7011 fax �tG-c Z�e ,fie D. Z G � W',-, r4: CERTIFICATION OF BUILDING AREA STREET ADDRESS OF JOB: 48-255 VISTA DE NOPAL APN: 646-110-025 DESCRIPTION OF WORK: LIVING ADDITION TO EXIST. SFD. NEW BUILDING AREA: -139 SF CONDITIONED AREA OWNER'S NAME: SHARON CHEZIK 9200 NW PRARIE VIEW RD. KANSAS CITY,'MO 64153 Coachella Valley Unified School District 83-733 Avenue 55 PO Box 847 Thermal, CA 92274 (760) 398 5909 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 L FACrL(W ;S.SERv10ES .); 4), I CON of („A,�'N'� � .�.. BUILDING & Sq �� ElY C Epf APPROVE( FOR CONSTRUG�'ION DA 0 Please Note: This Letter Verifies Conditioned Square Footage. Please call your. School District to Verify School Fees, Requirement for Cashiers Check or Money Order and Hours of Operation. For questions regarding this letter, please call: PERMIT CENTER (760) 777-7012 . ..� LAGU NAS �� -DE LA PAZ •4 May 19, 2014 Sharon Chezik - • . 9200 Northwest Prairie View Road F; Kansas;City, MO 64153 RE: 48255 Vista de'Nopal —Convert Covered Patio into Additional Room Dear'Ms. Chezik: - Your architectural request to convert the covered patio in the rear yard into an additional room at the residence listed -above has been approved by the..Architectural Committee with the following condition: •_ `A copy of the approved permit from the City must be provide to the onsite management office priorto commencement of work. ' Please note that this approval is valid'for ninety (90) days from the date of this letter. If the modification will not be• complete&w_ ithin that timeframe, you will need to re -apply for architectural approval., "' r We trust that only licensed, insured, contractors will be performing the work. Please be S reminded °that -any damage to:the"common area due to.construction should be repaired in a timely manner. Thank you for your cooperation in filing for architectural approval. If you have any questions or need further assistance, please feel free to contact me at 760.564.8864. Sincerel y � •MelissaMezza atCAM Community Associ tion Manager On Behalf of the Architectural Committee Laguna de la Paz HomeovnersAssociation" CC: Homeowner File l Enclosure: Signed Architectural Committee Certificate Laguna de la Paz Homeowners Association 1 48300 Vista de Nopal, La Quinta, California 92253-1 Telephone: 760.564.8864 Fax: 760.564.8867 ARCHITECTURAL COMMITTEE CERTIFICATE (Exhibit "A" to the Architectural Improvement Application and Agreement) The Architectural Improvement Application and Agreement was reviewed by the Architectural Committee on and has 'been: Approved !/ - Conditionally Approved Rejected Subject to the following Conditions set forth below Returned for Further Information Required Modifications Comments CSO P U "© fA-%o 0 II Q1' 1 Yes No , Recording to be sent by owner to the County Recorder's office for roof and/or exterior'wall modifications.. Deposit RequiredDeposit Amount$ t Arc r Committee Architectural Comms ee Architectural Committee Arc itectural Committee _ Arc 't aural Committee NOTE: THIS APPROVAL IS VALID FOR 90 DAYS FROM APPROVAL DATE MUST NOTIFY OFFICE UPON COMPLETION OF IMPROVEMENT Received:. ✓✓✓ ' - � � s -� � ` • ... _ Review. by: � ' � � • �� • Rev. Nov 2012 4 Page of This Material Sent `for. }Your Files SEP..� Per Your Request ElYour Review Or vE�-01;& Approval _ �. ❑ Checking CMVNZ�� Oti ElAtEthe request of: ' Other: ❑ i CJS - . YOUNG ENGINEERING SEMCE S' w .v 77-682 Country Club Dr. Ste. B, Palm Desert, CA 92211 ph. (760)772-5107 fax (760) 345-7620 t " Letter of Transmittal y .To: k City of La Quinta Today's Date: 9-9-14 78-495 Calle Tampico City -Due Date: 9-8-14 ' La Quinta, CA 92253 Project Address: ,' 48-255 Vista De Nopal , Attn: Angelica Plan Check #: 14-707 ` . Submittal: :. yD V. 1 ❑ 4th w ® .2nd ❑,: 5th .. ti - ` - ,� ❑ 3'd ❑ Other: - . We are forwarding - ® �'' By Messenger ❑ By Mail (Fed Ex or UPS) Your Pickup Includes: # Of. Descriptions: Includes:' # Of Descriptions: Copies: ; > Copies: . ❑ ' . :Structural Plans ® 1 Revised Structural Plans ® - 1 - Structural Calculations" ® 1 Revised Struct. Calcs ' ❑ .Truss Calculations Floor ❑ s : -Revised Truss and Roof FT,, - Soils Report D Revised Soils Report ' ❑" Structural Comment List ❑ Approved Structural; Plans ® 1 ., Redlined Structural Plans' ❑ Approved Structural Calcs t ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs �_ ' ❑ Approved Soils Report r, p -Redlined Soils Reports ' ' . ❑ Other: Comments: Structural content is.approvable. This Material Sent `for. }Your Files SEP..� Per Your Request ElYour Review Or vE�-01;& Approval _ �. ❑ Checking CMVNZ�� Oti ElAtEthe request of: ' Other: ❑ i CJS BUILDING ENERGY ANALYSIS REPORT PROJECT: I HENNESSEY RESIDENCE's ADDITION, 48255 VISTA DE NOPAL LA QUINTA, CA 92253 + Project Designer: . SUTTON REMODEL SPECIALISTS 78162 Calico Glen Dr ,Bermu,da Dunes, Ca�92203 760 248 8009 Report Prepared•by: _ : ARMANDO CHAVEZ TITLE 24,01F THE DESERT r 44890 SEELEY DR. LA QUINTA, CA 92253 , . .. . . 760, 278.1840 1,11 MTZ , 'VED - TITLE 26 OF THE DESERT _RE Job Number: AUG 2 0 2014 2014 -RF -001-1 R CITY OF LA QUINTA COMMUNITY DEVELOPMENT Date: CITY ofLAA ' 7/13/2014 16U.11.DJft1G & )U/NTA AFS. DEPT- 3" The EnergyPro computer program has been used to perform the calculations summarized in his compli'prep tTI ogram ha approvahand is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 ��I Efficie cy Standards. This program developed by EnergySoft,LLC — www. co dY Energ Pro 5.1 by EnergySoft User Number: 20648 RunCode: 201407-13722:33:01 28.2044_ -00 - � i � a _ L � � � r� � . ', > 1� PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name HENNESSEY RESIDENCE'S ADDITION Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 7/13/2014 Project Address 48255 VISTA DE NOPAL LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond: Floor Area 2,087 Addition 114 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 1,973 Existing Slab Unheated Slab-on-Grade None 1,973 Perim = 0' Existing Wall Wood Framed R-11 1,361 Existing Door Opaque Door None 20 Existing Slab Unheated Slab-on-Grade None " 114 Perim = 0' New Roof Wood Framed Attic R-38 114 Altered Wall Wood Framed R-13 164 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 12.0 0.710 0.60 none none Bug Screen Existing Front (E) 157.7 0.710 0.60 none none Bug Screen Existing Front (E) 53.3 0.710 0.60none none Bug Screen Removed Left (S) 33.3 0.710 0.60 none none Bug Screen Removed Left (S) 94.0 0.710 0.60 none none Bug Screen Existing Rear (Vloq 60.9 0.710 0.60 none none Bug Screen Existing Front (E) 32.0 0.400 0.35 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 8.9 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HA VC Ducted Ducted Attic, Roof Ins 2.1 Existing WATER HEATING E3Url ����` (UI��. Qty. Type Gallons Min. Eff Distribution a SqF r t tus I-UN CONST ;f Riv �nsc EnergyPro 5.1 by EnergySoft User Number." 20648 RunCode: 201407-13722:33:01 tPa e 3 of 11 �y J r� r PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R. Project Name RESIDENCE'S ADDITION Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration3/2014 7DateHENNi5SSEY SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the. special justification and documentation submitted. The Existing Roof 114 has a U -Factor greater than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION - Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. t _ CITY ,= . BUILDING & SAFETY t�FRT� '% D tri 10N. . 9 , tl� EnemyPro 5.1 by EnergySoft User Number: 20648 Run Code: 201407-13T22:33.'•01 E _ ID: 2014 -RF- 1-1R - i6age 4 of 11 PERFORMANCE CERTIFICATE:, Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date HENNESSEY RESIDENCE'S ADDITION ❑ Multi Family' m Existing+ Addition/Alteration F . PERFORMANCE CERTIFICATE:, Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date HENNESSEY RESIDENCE'S ADDITION ❑ Multi Family' m Existing+ Addition/Alteration 7/13/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 7.60 6.67 0.93 Space Cooling 206.45 189.49 16.96 Fans 33.01 30.26 2.75 Domestic Hot Water 16.23 16.23 —0.00 Pumps 0.00 0.00 0.00 Totals 263.28 242.64 20.64 Percent Better Than Standard: 7.8 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E).90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 413 190 . Fuel Available at Site: Natural Gas (S)- 540 94 Raised Floor Area: 0 (vv) 410 61 Slab on Grade Area: 2,087 (N) 539 12 Average Ceiling Height: 9.0 Roof 2,087 0 Fenestration Average U -Factor: 0.68 TOTAL: 357 Average SHGC: 0.58 Fenestration/CFA Ratio: 17.1 REMARKS ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSAB/LITY. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications. needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation'is accurate and complete. Documentation Author Company TITLE 24 OF THE DESERT 7/132014 Address 44890S EELEY DR. Name ARMANDO CHAVEZ City/State/ZipCity/State/Zip LA QU/NTA, CA 92253 phone ' 760 278.1840 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS -raters Designer or Owner (per Business &Professions Code) (�����•-� ciX:A UI� LDiNG Company SUTTON REMODEL SPECIALISTS ETy pEPT. Address 78162 Calico Glen Dr Name ROMEL FUENT S �,� City/State/Zip Bermuda Dunes, Ca 92203 Phone 760 248 8009• FpR a � k. F (grje'�I;TRIJCT,4G�gse # Date AVIV � - U TF Ene Pro 5.1 b Ene Soft User Number: 20648 RunCode: 201407-13722:3101 ID. -2 =QO -1R I Pacte 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name HENN8SSEY RESIDENCE'S ADDITION Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/13/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,973 0.049 R-19 0 0 Existing 4.2.1-A4 Slab 1,973 0.730 None 0 180 Existing 4.4.7-A1 Wall 527 0.110 R-11 0 90 Existing 4.3.1-A2 Wall 174 0.110 R-11 90 90 Existing 4.3.1-A2 Wall 331 0.110 R-11 180 90 Existing 4.3.1-A2 Wall 329 0.110 R-11 270 90 Existing 4.3.1-A2 Door 20 0.500 None 270 90 Existing 4.5.1-A4 Slab 114 0.730 None 0 180 New 4.4.7-A1 Roof 114 0.025 R-38 0 0 Altered 4.2.1-A21 E=4.2.1-A1 Wall 49 0.102 R-13 90 90 New 4.3.1-A3 Wall 115 0.102 R-13 180 90 New 4.3.1-A3 FENESTRATION SURFACE DETAILS ID Type Area Ll-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 12.0 0.710 Default 0.60 Default 0 Existing Double Metal Tinted 2 Window 53.3 0.710 Default 0.60 Default 90 Existing Double Metal Tinted 3 Window 47.3 0.710 Default 0.60 Default 90 Existing Double Metal Tinted 4 Window 53.3 0.710 Default 0.60 Default 90 Existing Double Metal Tinted 5 Window 1 3.8 0.710 Default 0.60 Default 90 Existing Double Metal Tinted 6 Window 53.3 0.710 Default 0.60 Default 90 Removed Double Metal Tinted 7 Window 33.3 0.710 Default 0.60 Default 180 Removed Double Metal Tinted 8 Window 25.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted 9 Window 25.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted 10 Window 9.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted 11 Window 35.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted 12 Window 27.5 0.710 Default 0.60 Default 270 Existing Double Metal Tinted 13 Window 16.7 0.710 Default 0.60 Default 270 Existing Double Metal Tinted 14 Window 16.7 0.710 Default 0.60 Default 270 Existing Double Metal Tinted 15 Window 6.0 0.400 NFRC 0.35 NFRC 90 New 2008 PRESCR. WDW P-D 16 JWndow 20.0 0.400 NFRC 0.35 NFRC 90 New 2008 PRESCR. WDW P-D (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Len H t LExt RExt Dist Len Hat Dist Right Fin Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Buq Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 1 1 1Y. U l`- (T 111 1-r- A 1 13 Bug Screen 0.761 HI III fl ftef� p r. � a W 1 14 15 Bug Screen IBug Screen 0.76 0.76 1 _'_" erre 1 YI=PT n 1 and 16 IBug Screen 1 0.76 1 'nuLo I I Ene Pro 5.1 6 Ene Soft User Number. 20648 RunCode: 201407-13722:33:01„ -1D 2D19JOQ1 1R Pa e 6 of 11 OF COMPLIANCE: Residentialof Project Name HENM�SSEY RESIDENCE'S ADDITION Building Type 2 Single Family 0 Multi Family 0 Addition Alone 10 Existing+ Addition/Alteration OPAQUE,CERTIFICATE AppendixLocation/Comments FENESTRATION SURFACE DETAILS EXTERIOR SHADING DETAILS CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name HENNESSEY RESIDENCE'S ADDITION Building Type ®Single Family ❑Addition Alone ❑Multi Family m Existing+ Addition/Alteration Date 7/13/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HA VC E 1973 1,973 17,757 1984 (N)-114 114 1,026 Totals 114 1,973 0 0 HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HA VC 1 Central Fumace 78% AFUE Split Air Conditioner 8.9 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HA VC Ducted Ducted Attic, Roof Ins 2.1 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c _ o �o a —slern Pipe �7ame L -en q t Pipe lamxmete Insul. Thick. Qty. HP Plenum Outside Buried ❑ 1 U1 d Y UF LA ❑ 1 B jo numn R, Q8,p r A -n 01 1 �,` 1kr_ �_ fi nr V!L ❑I 11-UITMNSTRUCTIO I EnergyPro 5.1 by EnergySoft User Number. 20648 RunCode: 20140743T22133:01_ ID: 2014-RF-001-1RP e 8 of 11 ` MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name HENNESSEY RESIDENCE'S ADDITION Date 1711312014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 Ml A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, e u °� ' "� "-" I�me ; t matntenanj�e and -wind; §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor rVr`dan t -or i ncldsed emirdIy' rf V 1 conditioned space. SAFE §1500)4: Solar water -heating systems and/or collectors are certified by the Solar Ratin And CerdfiGatlon Co°p O.ratior.)f_g - FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 20648 RunCode: 201407-13722:33:01 DATOD: 2014-RF-001-1R_Page 9 of 11 MANDATORY:MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date HENNESSEY RESIDENCE'S ADDITION 1711312014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections " 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is - • MANDATORY:MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date HENNESSEY RESIDENCE'S ADDITION 1711312014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections " 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or.constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. ` §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. - • • - • • . - §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted withcoating that is water retardant and provides shielding from solar .a radiation that can cause degradation of the material. ' 150 m 10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and E ui nient Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency - Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. -` §114(b)l : Any pool or spa heating equipment shall be installed with at least.36" of pipe between filter and heater, or dedicated suction' and return lines, or built-up connections for future•solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off -pe alk electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve re uirements of §150(p). Residential Lighting Measures: '- §150(k)1: High efficacy luminaires or. LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13.Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy.lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant . sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a ' manual -on occupant sensor. - §150(k)9: Permanently. installed lighting that is internal to cabinets shall use no rnore-than-20-watts-of-power_per_lineartooQ illuminated cabinet. . I F np . ! n' - . ' •C BUILDING SAFETY & DEPT. _ _ - - FOR CONSTRUCTION ' EnergyPro 5.1 by EnergySoft User Number. 20648 RunCode: 201407-13722:33:01 ID: 2014 -RF -001-1 R Apge 10 of 11-• 4 - j�DATE BY w 4 •i r • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date HENNE9SEY RESIDENCE'S ADDITION 1711312014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the, same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours.- EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. t • CITY ®F LA QUINTA . ' BUILDING & SAFETY DEPT, APPROW ED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft User Number. 20648 RunCode: 201407-13722:33:01 7D-2-0 ----Pa—g4 11 of 11