Loading...
13-0882 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 1-3--0;00882 Property Address: 49615 AVENIDA VISTA BONITA APN: 773-350-053-53 -14496 - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 75000 Applicant: a Twit � BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or gineer: C1r4' LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 807645 Date:' 3- 15 Contractohk rs G� 1 ✓ ti OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State . License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)-: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of•property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed • pursuant to the Contractors' State License Law.). I 1 I am exempt under Sec. BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: �LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/05/13 Owner: PETERSON 49-615 AVENIDA VISTA BONITA LA QUINTA, CA 92253 (760)000-0000 Contractor: SCRIVENS CONSTRUCTION INC, GL- P.O. BOX 13302 IJ PALM DESERT, CA 92255 (760)837-9918 Lic. No.: 807645 -—-——-—=—---—---—--—----------------———--- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ' _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier STATE FUND Policy Number 902363512 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section - 3700 of the Labor DatCod shat w orthwit comply with those provisions. e: Ap l cant:, ' WARNING: FAILURE TO SECURE WORKERS OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000)- IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. .. 1. Each person upon whose behalf this application is made, each person at whose request and for , whose benefit work is performed under or pursuant to any permit issued as a result of this application, _ the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City - of La Quinta, its officers, agents and employees for any act or omission related to the work being- ..t - performed under or following issuance of this permit. ' 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject ` permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to build' g co truction, and her authorize representatives - of this county to enter upon the.above-mentioned prope y orpection purpos " Signature -IA Agentl: - Application Number 13-00000882 Permit . . ELECTRICAL 2013 Additional' desc Permit Fee 23.83 Plan Check Fee .Ob " Issue Date . . . . Valuation . .. 0 Expiration Date 3/04/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 23.83 Permit . . MECI•IANICAL 2013 Additional, desc . Permit Fee . . . . 11.92 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date 3/04/14 Qty Unit Charge Per Extension 1.00 11.9200 EA MECH APPL REP/ALT ---------------------------------------------------------------------------- 11.92 Permit . . PLUMBING 2013 Additional desc . Permit Fee 71.52 Plan -Check Fee .00 Issue:Date . . Valuation . . . . 0 Expiration Date.. 3/04/14 Qty - Unit Charge Per Extension 4.00 11'.9200 EA PLBG FIXTURE/TRAP 47.68 1.00 11.9200 EA PLBG WATER INST/ALT/REP 11.92 1.00 11.9200 LS PLBG GAS SYS,,1-4 OUTLETS 11.92 Permit REMODEL 2013. Additional desc . Permit Fee . . 134.42 Plan Check Fee .00 Issue Date Valuation. 0 Expiration Date 3•/04/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC REMODEL, 1ST 100 SF 48.62 4.00 21.4500 EA- MISC REMODEL, ADDL 500 SF 85.80 ----------------------------------------------------------------------------- Special Notes and Comments renovation new windowes, plumbing, fireplace and elec. remodel. per ,2010 _ calif building codes. July 24, 2013 11:48:50 AM JJohnson., LQPERNUT Application Number 13-00000882 -----------------.----------------------------------------------------------- Other Fees . . . . . BLDG STDS ADMIN (SB1473) 4.00 HOURLY PLAN CHECK 332..50 PLAN:CHECK, ELECTRICAL 23.83 PLAN CHECK, REMODEL 201.63 PLAN CHECK, MECHANICAL 4.77 PLAN CHECK, PLUMBING 83.43 :STRONG MOTION (SMI) - RES.- 7.50 Fee summary Charged Paid Credited Due -------------.nr.-- T Permit F44 2l. --------=- ?ai Fq ---------------------=-------- nn .00 1 241.69 Plan Check Total .00 .00 .00 .00 Other Fee Total 657:.66 .00 .00 657.66. Grand Total 899.35 .00 00 899.35 LQPERMIT - BinU ` City of la Qulnta Building a Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: b���i4 vij,i' Owner's Name: ,"W /V . A. P. Number: Address: � g -4^t Legal Description: tract r• Con o . � J i dC' C City, ST, Zip: ZZ_ j3 Telephone: ............................................ Address: Project Description: City, ST, Zip: / ✓�n���OSG/T 22 ✓ c�p�� G��C�% c.i►- TeleP hone 3 �.. � State Lic. City Lic. #: Arch., Engr., Designer: If/e,.,J Tr-, aj Address: City., ST, Zip: Tele hone:?:;'s,:"€`•:>`:3,:::";::::;<: # N Construction Type: Occupancy: e Lic. #: one): New Add'n Alter Repair Dem oSta Project type (circle Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: %SGiO APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted r71Item Amount Structural Calcs. Reviewed, readyor corrections\ Plan Check Depo Truss Calcs. Caned Contact P". ----- c Plan Che .lance. Title 24 Calcs. Plans picked up Cons ,*' -c 2463-1) Flood plain plan Plans resubmitted M a Grading plan 2°" Review, ready for correctio s/issue Electrical V r— Subcontactor List Called Contact Person lumbing Q Grant Deed Plans picked up S.M.I. V N Erw H.O.A. Approval Plans resubmitted G -tiding T'() ( 7 IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee V� C Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr , Date of permit issue School Fees otal Permit cc N5 RFC- �12b[b -"Ooz LQ WU11 ILEA, V/ -A VLLVV Project Designer: Mark B. Valentino, Architect 77-670 Springfield Lane, Suite 7A Palm Desert, CA 92211 (760) 200-5099 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 - 'Job Number:, ReUMVEW JUL 08-2013 - Date: ° !? CITY of LA QUINTA 6/26/2013 A r BUILDING & SAFETY DEPT, The EnergyPro computer program has been used to perform the calculations summarized in this compliance reportmh's• �regJ s I and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 E uifdl a rrne,g ffi �er Stn rds. This program developed by EnergySoft, LLC —www.energyioft.comFOR ,%ONSTR TION 01. 1 .1 If,— . t EnergyPro 5.1 b EnergySoft User Number: 6712 RunCode: 2013-06-26718:45:22 Iby I f . f t t i U- Factor PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Overha Project Name Peterson Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Additicn/Alteration 1612612013 Date none Project Address' 49-615 Avenida Vista Bonita La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Addition 2,020 0 # of Stories 1 26.9 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. 0.80 INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status 179.6 Roof Wood Framed Attic R-19 2,020 Existing 0.80 Wall Wood Framed R-11 1,681 Existing 240.0 Door Opaque Door None 48 Existing 0.29 Slab Unheated Slab -on -Grade None 2,020 Perim = 181' Existing FENESTRATION Orientation An Front (N) Front (NE) Left (E) Rear (S) • Rear (S) Rear (S) a(ft) U- Factor SHGC Overha 68.0 1.280 0.80 none 26.8 0.530 0.29 none 26.9 1.280 0.80 none 179.6 1.280 0.80 none 240.0 0.530 0.29 none 6.9 0.400 0.35 none Sidefins Exterior Shades Status none Bug Screen Existing none Bug Screen New none Bug Screen Existing none Bug Screen Removed none Bug Screen New none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Packaged Air Condition. 11.0 SEER Setbaci Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing IWATER HEATING I BUILDING &FETY Qtv. Tvne Gallons Min. Eff Distribution A res„— • EnemvPro 5.1 by EnemySoR User Number., 6712 RunCode: 2013-06-26T18:45:22 ID: TA :PT. N i • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Peterson Residence Remodel Building Type ® Single Family ❑ Addition Alone I . ❑ Multi Family ® Existing+ Addition/Alteration Date 1612612013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The insaector must receive a completed CF -4R form for each of the measures listed below for final to be given. CITY OF LA Qui NFM IJUILDING a- 100MOVED ria v FOR CONSTRUCTION Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-06-28718:45:22 1 : Pa e 4 of 10 • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition AlonE Date Peterson.Residence Remodel o Multi Family m Existing+ Addition/Alteration 6/26/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 12.28 10.57 1.72 Space Cooling 173.12 130.72 42.41 Fans 35.86 27.12 8.74 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 221.27 168.40 52.86 Percent Better Than Standard: 23.9% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 • (N) 440 95 Fuel Available at Site: Natural Gas (E) 560 27 Raised Floor Area: 0 (S) 448 •247 .Slab on Grade Area: 2,020 (W 650 0 Average Ceiling Height: 10.5 Roof 2,020 0 Fenestration Average U -Factor: 0.72 TOTAL: 369 Average SHGC: 0.42 Fenestration/CFA Ratio: 18.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and com tete. Documentation Author = Company . Scott Design and Title 24, inc, 6/16/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 2004780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design,` duct sealing, verification of refrigerant charge, insulation installation quality, and build i nvel,�oe sealing re uire' installer testing and certification and field verification by an approved HERS rater. C0� QUINT �I �,�-� Designer or Owner (per Business &Professions Code) AFM DE Company Mark B. Valentino, Architect C�{{'��77-670 2gpRa �- Springfield Lane, Suite 7A Mark Valentino 1r - N AddressName9:4 City/State/zip Palm Desert, CA 92211 Phone (760) 200-5099 Signed License # Date DATE BY EriemyPro 5.1 by EnemvSoft User Number: 6712 RunCode: 2013-06-26718:45:22 ID: • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Peterson Residence Remodel Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 6/26/2013 OPAQUE SURFACE DETAILS Surface TVDe Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 27020 0.049 R-19 0 20 Existing 4.2.1-A4 Altered Residence Wall 254 0.110 R-11 0 90 Existing 4.3.1-A2 Altered Residence Door 48 1.450 None 0 90 Existing 4.5.1-A1 Altered Residence Wall 43 0.110 R-11 45 90 Existing 4.3.1-A2 Altered Residence Wall 533 0.110,R-1 90 90 Existing4.3.1-A2 Altered Residence Wall 201 0.110 R-11 180 90 Existing4.3.1-A2 Altered Residence Wall 650 0.110 R-11 270 90 Existin 4.3.1-A2 Altered Residence Slab 2,020 0.730 None 0 180 1 Existin 4.4.7-A1 Altered Residence FENESTRATION SURFACE DETAILS ID T e Area U -Factor SHGC Azm Status Glazing Type Location/Comments- 1 Window 48.0 1.280 Default 0.80 Default 0 Existing Single Metal Tinted Altered Residence 2 Window 20.0 1.280 Default 0.80 Default 0 Existing Single Metal Tinted Altered Residence 3, Window 26.8 0.530 NFRC 0.29 NFRC 45 New Double Metal Tinted Altered Residence 4 Window 20.0 1.280 Default 0.80 Default 90 Existing Single Metal Tinted Altered Residence 5 Window 6.9 1.280 Default 0.80 Default 90 Existing Single Metal Tinted Altered Residence 6 Window 64.0 1.280 Default 0.80 Default 180 Removed Single Metal Tinted Altered Residence 7 Window 80.0 0.530 1 NFRC 0.29 NFRC 180 New Double Metal Tinted Altered Residence 8 Window 6.9 0.400 NFRC 0.35 NFRC 180 New Double Non Metal Tinted Altered Residence 9 Window 15.6 1.280 Default 0.80 Default 180 Removed Single Metal Tinted Altered Residence 10 Window 30.0 1.280 Default 0.60 Default 180 Removed Single Metal Tinted Altered Residence 11 Window 40.0 1.280 Default 0.80 Default 180 Removed Single Metal Tinted Altered Residence 12 Window 30.0 1.280 Default 0.80 Default 180 Removed Single Metal Tinted Altered Residence 13 Window 80.0 0.530 NFRC 0.29 NFRC 180 New Double Metal Tinted Altered Residence 14 Window 80.0 0.530 NFRC 0.29 NFRC 180 New Double Metal Tinted Altered Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht in Len I H t LExt I REA Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 11 12 Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 A, rimp ki 1r-1 q l UC Ene Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-26718:45:22 /D: • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Peterson Residence Remodel Building Type ® Single Family ❑ Addition Alone- D Multi Family ® Existing+Add tion/Alteration Date 1612612013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Existing HVAC Altered Residence 2,020 21,210 1985 Totals 01 Z0201 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing HVAC 1 Central Fumace 80% AFUE Packaged Air Conditione 11.0 SEER Setba�-k Existing HVAC DISTRIBUTION System Name Heating Duct Coolin Duct Location R -Value Ducts Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 D Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE S'andby Loss or (Pilot Ext. Tank dnsul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SIItSTEM PIPING Control Hot Water Piping Length n 0 a — System Name Pipe --en th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-26718:45:22 ID: Page 7 of 10 a 1� MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Peterson Residence Remodel Date 1 6/26/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e. §i 16(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. '11 18(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the . installation of a Cool Roof is specified on the CF -1 R Form. ' • 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 Od : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when s ecified on the CF -1 R Form. 4150(q): Mandatory Vapor barrier installed in Climate Zones 14 or 16. "§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is ..equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. A1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c)- c .§1'500)1 §1'500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation havinq an installed thermal resistance of R-12 or greater. . §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water 'tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, rnee"ts 123-A. j r@qu e 5 n a a uent 150 A: Insulation is protected from damage, including that due to sunlight, moisture i ' 3 m m .'n � a® n §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant `conditioned space. Qf:-i's_,e1"i se e iEZ 150(0)4: Solar water -heating systems and/or collectors are certified by the Solar Ra tin and Certification Corporation. I, DATE BY ' EnergyPro 5.1 by EnergySolt User Number. 6712 RunCode: 2013-06-28718:45:22 ID: Page 6 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Peterson Residence Remodel 6/26/2013 §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes :. unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150(k)6: Lightina inte ral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled-by- manual-on occupant sensor. r--�"" ._.-' • r , ii► §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 2b wat s; of power per linear foot of Y DEPT. illuminated cabinet. i wcTiON EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-26T18:45:22 ID: _ —Page 9 of 10 • 17 - MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Peterson Residence Remodel 1612612013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(kyl 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, .,closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contactl (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shal be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTIOA 3: Permanently installed "luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR -not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable ` requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shalt' comply with the applicable requirements of Sections 130 131 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more .dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 1119. CITY OF LA CSU I N BUILDING & SAFETY D APPROVED FOR CONSTRUCTION DATE BY I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-26718:45:22 ID: Page 10 of 10 fA PT.