Loading...
07-1973 (RER)P.O..BOX 1504. VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253. BUILDING &SAFETY DEPARTMENTINSPECTIONS (760) 77777153 BUILDING PERMIT Date: 9/11/07 . Application Number: _ 07-00001973 Owner: " Property Address: 78805 WAKEFIELD CIR SUZY FELSON APN: 604-431-004-12 . -23995'- 78-805 WAKEFIELD Application description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253 �. Property Zoning: LOW DENSITY RESIDENTIAL " P*,ppli00tion Voluotion: 20000 • p Contractor. Applicant: Architect or Engineer: ATLANTAS G C p� 78030 "CALLE BARCEL LA QUINTA, CA 9225 O (760) 777-1312 tic. No.: 799746 e, LICENSED CONTRACTOR'S DECLARATION 'WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury that,l am licensed-under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals e, and my License is infull force and effect. _ I have and will maintain a certificate of consent to self=insure for workers' compensation, as provided License Clas : B nens eN : 799746 - for by Section 3700 of the Labor Code, for the performance of the work.for which this permit is issued. Date: r $�.. Contractor: _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor -- - - --- Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER-BUILDER DECLARATION insurance carrier and policy number are: - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the - - Carrier .EEMPT Policy Number EEMPT following reason (Sec. 7031.5, Business and Professions Code:. Any city or county that requires a permit to I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I should become subject to rkers' compensation provisions of Section , License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 7 of the Labor Code, I shall fo it wit hose "provisions. - that he or she is-exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5.by - any applicant for'a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ' Date: i Applicant: (_) I, as owner of the property, or my employees with wages as their sole compensation,_ will do the work, and. the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The - WARNING: AILURE TOSECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND " and who does the work himself or herself through his or her own employees, provided that the - DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN - improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.)" APPLICANT ACKNOWLEDGEMENT (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the .Director of Building and Safety for a permit subject to the ' 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a.contractor(s) licensed - 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 _I am exempt under Sec.. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: " Owner." 2. Any permit issued as a result of this application becomes null and void if work is not commenced " within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject 4; CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city andcounty ordinances and state laws relating to building construction, n ereby authorize representatives . of. this cont to -ter upon the.above-mentioned property for insp �ose _Lender's Name: (��i _ . - - Date: r'd .Signature (Applicant or Agent): - Lender's Address: LQPERMIT Application Number 07-00001973 .. Special Notes and Comments - - -- -_------ - - - - -- t. FT. --------------------------------------------------------------------------- Other Fees . . . . . . ENERGY REVIEW FEE. 7.61 STRONG MOTION (SMI) - RES 1.00 - Fee summary Charged Paid Credited Due Permit Fee Total 218.75 .00 .00 218.75 ' 812,n Chert, T,t l gni .49, no nn 191,4.A Other Fee Total, 8.61 .00_ f .00 8.61 Grand Total 328.85 .00 .00 328.85 , LQPERMIT. 1 Application. Number . . . . . 07-00001973 —Permit BUILDING PERMIT . Additional desc . Permit Fee 117.00 Plan.Check Fee 76.05 Issue Date` Valuation 10000 Expiration Date 3/09/08 Qty Unit Charge Per Extension, BASE FEE 45.00 8..00 9.0000 THOU. BLDG. 2,001-25,000 72:00 ^� Permit . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . 26.25 PTan_Check Fee 6.56 Issue Date Valuation . . . . 0 Expiration Date :3/09/08 Qty Unit Charge Per Extension BASE FEE 15.00 25.00 .4500 EA. ELEC DEVICE/FIXTURE >20 11.25 Permit MECHANICAL Additional desc . Permit Fee . . . 39.50 Plan Check Fee Issue Date . . Valuation 0 Expiration Date 3/09/08 Qty Unit Charge Per. Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 1.00 9.0000 EA MECH B/C.<=3HP/100K BTU 9.00 1.00 6.5000. EA- MECH VENT FAN 6.50 Permit .. : . PLUMBING Additional desc . Permit Fee . . . . 36.00 Plan'Check Fee 9.00 Issue Date Valuation 0 Expiration Date 3/09/08 Qty Unit .Charge Per Extension BASE FEE' 15.00 : 3.00 6,0000, EA PLB FIXTURE 18.00 1.00..`-_ 3.0000 EA PLB WATER INST/ALT/REP 3.00 ------ - - - - -- - - - - - Special Notes and Comments :. REMODEL GARAGE INTO FAMILY ROOM 170 SQ. LQPERMIT _ _. CERTIFICATE OF COMPLIANCE w�scy Desert Sands Unified School District oco 47950 Dune Palms Road ¢ eERMUDADUNES O RANCHO MIRAGE Cf Date 9/11/07 La Quinta, CA 92253 INDIAN WELLS (760) 771-8515 d PALM DESERT . No. 29682 - � LAQUINTA `-+PINDIO y� Owner Felson APN # 604-431-004-12 Address 78805 Wakefield Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. . ` Street S.F. Lot # No. Street S.F. Unit 1 78805 Wakefield - 170 Unit 6 Unit 2 Unit 7 t " Unit 3 1 Unit 8 Unit 4.. Unit 9 Unit 5 Unit 10 . Comments convert garage into living space At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/Walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping,'cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees•at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies,that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00'X 170 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By N/A - Art Lambrose Check No. N/A Name on the check Telephone 760-578-3584 Funding Exempt By Dr. Doris Wilson Superintendent' j r Fee collected /exempted by Yolanda Garcia Payment Recd s $0.00. }" �.^Over/Ur_ele�' �f Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the Districtfs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting ' _ �0 A-,-. r 1st - Apin7 30 ' ' • ...' I. • • �k �r L v bet y=.Frid�y:.7.:D0:aie>t.'t •5:'30.P[\11-6 &SAFETY DIEI'T. ! I _ .Qo.e a.p:u><.' ' ' ' ROVE D S (� v f (A- So b :..sinnda:• rie.' . �.- /$ �ob(I Cove�r>ili>men otdajrs�• i At0>d@•' F ONS RU, N . 4 J '�VTay .lst -'S je b0'-_( 01� . 1 1 e l r 1- t /L� g✓i>�W �rV ( oa'day•- P iglay: 6:t)a.m. tol. DA ql�l 1 'Satpxdyy' ® ®. , I O4 L:�'44- .ie�Svr� 4+ Q�ld �^F„ Off' � �N.'hZOAD' EA URED.' :4-61rrR•OF,'1:C>T. �h m >� 'w. �1EA5uktD• �.:GENT�R'OP. T. nstru ion is NOT PERM D - :� V MIN_ Holiday. A E4NSPECnON FEE OF $30 WILD BE CHARGED IF THE APPROVED ews Da 1. ;'"f . y PLANS AND JOB CARD ARE NOT ON ark Luthe ng Jr. Day THE SITE FOR A SCHEDULED ON. I •�.' _ ., _ iJ.. , ... .4�3 �den�s Day I , o a ria ay NOD ONS fence D L bor Day pC� Ve±erarr S Dai_. I" . 6, go fl . an wiving Da � ,nas Day. ,c " �� 1�' •GNr'.`. t '� j clp-�o Lo„AN DEBRI oNT ! ,_...,....•t� , WRo�.� ,t 40-0 IS REQ IRED 0 HE 10B SITE DURIN ALL :......_.. J.y,. Ran PHASE OF CONSTRUC IONAND, - - EfViPTI AS NECESSARY. FAILURE TO SO esril o California Building, Plumbing, Mechanical,des and ordinances." Remove notesrfl DN�TCNE7EUP SE OF TI � CONTRACTOR." I I ��"' N 175 .� ., h P 1 �-• J -- SLIGHT OVER CONTROLS CONVENIENCE OUTLET 5'=0". WITHIN 25' OF EQUIPMENT . MIN. PER SEC. 309.1 MECHANICAL EQUIPMENT WORKING- SPACE AT SHALL BE FASTENED t CONTROLS ,. IN . PLACE, PER SEC: 304 30" . M .. WARM AIR `: D MIN. 24" WIDE1 PLYWD. FLOOR .I .g FURNACE ACCESS WAY.- . .6_M LIGHT SWITCH COMBUSTION AIR ATTIC INSULATION 20' MAX. R - SOURCE; .VENTED PLY.WD.` PLATFORM "LARGE,ENOUGH 'ATTIC ON. 2x6's. ®24"0/C ACCESS TO -REMOVE LARGEST PIECE OF EQUIPMENT BUT ' NOT LESS THAN. 30"x22." ACCESS. . OPENING WITHIN 20 FT. OF FURNACE FURNACE-.JN ATTIC. -., PER C.M.C. SEC. -319:1=319X = N.T.S. d TITLE 24 REPORT • Title 24 Report for: .� SUSSIE•�ELSON ` 78-805 WAKEFIELD r LA QUI NTA, CA Project Designer: OWNER SUSSIE NELSON LA QUINTA, CA {. Report Prepared By: - ' ADRIANA GIL Adriana Gil . 74-854 Velie Way Ste. #8 ' Palm Desert, CA 92260 (760) 404-791.7 Job Number: ADY637-0707 ,n � 0 �n o 90Zx Date: ®:> 9/10/2007 rn C z 0: o � The Ener Pro computer program has been used to perform the calculations summarized in this compliance report. 9Y P P 9 P P P authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building This o ram has a rows 4a�is P PP Energy iciency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: ADY637-0707 User Number 5553 .s _ .� A Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R . SUSS-I.ENELSQN Existing Floor Area: ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: Project Title Fuel Type: Slab on Grade Area: Natural Gas Date 78 -8.0.5 -WA- KEF_I.ELD LA QUINTA Area: 16 ft2 Avg. U: 0.34 Project Address 9.4% Avg. SHGC: 0.28 Wood_ Building Permit # Adrian.a_G-H -R-1.5_ _R=0..0_ -4.5--90 (760) 404-7917 Wall_ Documentation Author 1.20 -0.0.95_ Telephone Plan Check/Date FaePin Wall- Wood- ('A -Climate -Zone -1-5 Field Check/Date CompliNrfce Method -31.5__9.0 Climate Zone None_ TDV Standard Proposed Compliance _ kBtu/sf-yr) Design Design Margin Space Heating 4.76 9.38 -4.62 Space Cooling 82.99' 69.77 13.22 Fans 9.68 9.20 0.48 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 97.43 88.35 9.08 Standard: Building Type: [X-] Single Family [X-1 Addition Existing Floor Area: ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (NE) 45 deg Fuel Type: Slab on Grade Area: Natural Gas Fenestration: Average Ceiling Height: 8.0 Area: 16 ft2 Avg. U: 0.34 Ratio: 9.4% Avg. SHGC: 0.28 Total Conditioned Floor Area: 170 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 170 ft2 Average Ceiling Height: 8.0 ft Number of Dwelling Units: 0.13 9.0_ Number of Stories: 1 Wood_ BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .RO-OM_P_TAC 17.0 1,360 -0.1.3_ Conditioned- -Setback- 2 -n/a OPAQUE SURFACES JA IV Reference Insulation Act. ❑New Type Frame Area U -Fac. Cay. Cont. Azm. Tilt -Roof Wood- 1.7.0- -0.026_ -R=38- _R=0.0. 9.0_ 0 Wall_ Wood_ 7.6_ _0..095_ -R-1.5_ _R=0..0_ -4.5--90 New- Wall_ Wood_ 1.20 -0.0.95_ -R_15_ _R=0...0_ -1359.0 Wall- Wood- 1.00_ _0.0.95- -R_1.5- _R=0.0_ -31.5__9.0 _Door None_ 2-0 _0..5.00_ -None_ _R=0..0_ -3-1.5--90 Gains Condition Y / N Status JA IV Reference Location / Comments DK ❑New _01A8 Whole [X ❑New 0.9=A4 V'✓.hole IX ❑New -0.9_A4 Whole [)--Q ❑New -09_A4 Whole IX 1-1 New- .28=A4 _Whole Run Initiation Time: 09/10/07 11:36:12 Run Code: 1189449372 EnergyPro 4.3 by Energysoft User Number: 5553 Job Number: ADY637-0707 Paae:3 of 8 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R . SUSSIE NELSON 9/10/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1_ Window—Eront_(NE) _16.0_ _0...3_4.0 _NERC__0..28 _NERC. 45_ —9.0_ New—BETTE R-3.1-1.1 LT—Vifty-Llow-E Whole 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference. Status Comments Slab Perimeter 42 None No Insulation 26-A1 New Whole Run Initiation Time: 09/10/07 11:36:12 Run Code: 1189449372 EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY637-0707 Page:4 of 8 Certificate Of Compliance: Residential (PC -rt 3 of 3) CF -1 R SUSSIE NELSON 9/10/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type ROOM PTAC Room Heat Pump 6.59 HSPF Room PTAC without Side 9.5 EER New Setback Louvers HVAC DISTRIBUTION Duct Location Heating Cooling Location ROOM PTAC Ductless / with Ductless' n/a Fan Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? n/a New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ML Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: ADRIANA GIL Title/Firm: OWNER Title/Firm: Adriana Gil Address: SUSSIE NELSON Address: 74-854 Velie Wa Ste #8 LA QUINTA CA Telephone: tic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) y Palm Desert CA 92260 Telepho e:(760 404-7917 i k'l) (signal r ! date) EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY637-0707 Paae:5 of 8 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El nx ElCF-6R ❑ Form: EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY637-0707 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY637-0707 Page:6 of 8 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment a X❑ X❑ X❑ C a] ❑ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ X❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ X❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1' 9(d) that does not turn on automatically or have an always on option. 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are E]X ❑ El certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ X❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). JEnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY637-0707 Page 7 of 8 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE SUSSIE NELSON 9/10/2007 SYSTEM NAME FLOOR AREA ROOM PTAC 170 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 6,000 Total Output (Btuh) 6,000 Output (Btuh/sqft) 35.3 Cooling System Output per System 6,800 Total Output (Btuh) 6,800 Total Output (Tons) 0.6 Total Output (Btuh/sgft) 40.0 Total Output (sgft/Ton) 300.0 Air System CFM per System 280 Airflow (cfm) 280 Airflow (cfm/sgft) 1.65 Airflow (cfm/Ton) 494.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 464 4,763 975 296 3,962 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4,763 975 3,962 CARRIER 52EQA2073 2,871 3,719 3,747 Total Adjusted System Output 2 871 3,719 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2pm 1 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 70.0 of 70.0 of 82.6 of Outside Air 0 Supply Air Ducts 0 cfm 82.6 of Supply Fan Heating Coil 280 cfm ROOMS 70.0 of 70.0 of Return Air Ducts COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 11.0/77.6OF 76.0/69.8OF 76.0/69.9OF Outside Air 0 cfm 76.0/69.8 of 66.4 / 65.9 of Supply Fan Cooling Coil 280 cfm h Return Air Ducts `{ Supply Air Ducts 66.4 / 65.9 of 74.0% R.H. ROOMS 76.0 / 69.8 of EnergyPro 4.3, by EnergySoft User Number: 5553 Job Number: ADY637-0707 Page:8 of 8