BRES2016-000678-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
c&t,, 4 4v Q"Kroi
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BRES2016-0006
Property Address:
49275 AVENIDA EL NIDD
APN:
658290010
Application Description:
CHILD RESIDENCE / DEMO & REMODEL
Property Zoning:
Application Valuation:
$15,000.00
Applicant:
MARK CHILD
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION 1
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($50 r:
L ( ) I, as owner of the property, or my employees with wages as their sole
Fmpensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or he did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed contractors
t construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
e tractors' State License Law.).
L-GiI am exempt under Sec. . B. this reason
Date: e
CONSTRUCT N LENDING AGENCY
I hereby affirm under penalty of per' ry that there is a construction lending agency for
the performance of the work for w ich this permit is issued IS.
3097, Civ. C.).
Lender's Name:
Lender's Address:
11111111111111111111
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/19/2016
Owner:
MJ3 LLC / LMH REALTY INC
80215 VIA VALEROSA
LA QUINTA, CA 92253
�j
f
Llc. No.:
Contractor:
OWNER BUILDER
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number: _
1 certify that in the performance of the work for which this permit is issued, I
shall of employ any person in any manner so as to become subject to the workers'
co pensation laws of California, and agree that, if I should become subject to the
workers' com oration provisions of Section 370 th Labor Code, I shall forthwith
C,
with
it _se
p visions.
Dat App scant:
WARN G: FAILURE TO SECURE WORKER COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO RIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
'request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to . r upon the
above -men 'oned property for inspection purpos
Dat Signature (Applicant or Agent)
FINANCIAL •• 1,
DESCRIPTION ACCOUNT
QTY AMOUNT PAID PAID DATE
HOURLY PLAN CHECK - ESG 101-0000-42600
0 $186.38 $186.38 2/18/16
PAID BY METHOD
RECEIPT # CHECK # CLTD BY
49275 AVENIDA EL NIDO CHECK
R13026 1042 SKH
Total Paid for BLDG CITY STAFF - PER HOUR: $186.38 $186.38
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$36.99
$36.99
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$15.24
$15.24
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$145.03
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86.
$47.86
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $245.12 $245.12
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.09
$12.09
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.83
$4.83
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$4.83
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
Total Paid for MECHANICAL: $33.84 $33.84
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$48.36
$48.36
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$48.36
$48.36
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$12.09
$12.09
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
$24.17
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.09
$12.09
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.09
$12.09
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD.BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
Total Paid for PLUMBING FEES: $157.16 $157.16
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$174.00
$174.00
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$139.20
$139.20
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
2/18/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$134.88
2/18/16
PAID BY
' ` .•METHOD
RECEIPT #
CHECK #
CL TO BY
49275 AVENIDA ELNIDO
CHECK
R13026
1042
SKH
Total Paid for REMODEL: $497.39 $497.39
DESCRIPTION
ACCOUNT
QTY
AMOUNT
".PAID. ,
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0•
$1.95
$1.95
2/18/16
PAID BY
METHOD
RECEIPT #
'CHECK #
CLTD BY
49275 AVENIDA EL NIDO
CHECK
R13026
1042
SKH
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.95 $1.95
TOTALS::4
Description: CHILD RESIDENCE / DEMO & REMODEL
Type: BUILDING, RESIDENTIAL Subtype: REMODEL
Status: APPROVED
Applied: 1/15/2016 MFA
Approved: 2/18/2016 JJO
Parcel No: 658290010 Site Address: 49275 AVENIDA EL NIDO LA QUINTA,CA 92253
Subdivision: LA QUINTA GOLF ESTATES 1 Block:
Lot: 119
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $15,000.00 Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0
No. Unites: 0
1/29/2016
Details: INT. REMODEL PER 2013 CRC CODES.SQ. FT.OF HOME IS BEING REDUSED FROM 4242 SQ. FT. TO 3989 SQ. FT. DINING ROOM IS BEING
CONVERTED TO OUTDOOR LIVING AREA.
Printed: Friday, February 19, 2016 8:58:42 AM 1 of 5
17117 SYSTEMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE'
COMPLETION DATE
NOTES
NOTE
JIM JOHNSON
1/29/2016
1/29/2016
STRUCTURAL REVIEW COMPLETE - APPROVED WITH
NOTE
JIM JOHNSON
2/22/2016
2/18/2016
CONDITIONS, SEE STRUCTURAL REVIEW AND TRANSMITTAL
SHEET FOR ADDITIONAL INFORMATION.
PLAN CHECK COMMENTS
FROM CONSULTANT
JIM JOHNSON
1/29/2016
1/29/2016
RECEIVED
PLAN CHECK COMMENTS
FROM CONSULTANT
JIM JOHNSON
2/17/2016
2/17/2016
RECEIVED
PLAN CHECK PICKED UP
RAMSES SEVILLA
1/29/2016
1/29/2016
MARKE CHILD PICK UP PLANS
PLAN CHECK SENT TO
KAY HENSEL
1/15/2016
1/15/2016
STRUC TO ESGIL FOR STRUCTURAL PLAN CHECK - DUE BACK
OUTSIDE PC
1/29/2016
Printed: Friday, February 19, 2016 8:58:42 AM 1 of 5
17117 SYSTEMS
Permit Details RENUMBER
`�� City of La Quints B1 '-0006
PLAN CHECK SENT TO
CLTDBY
DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY
HOURLY PLAN CHECK -
101-0000-42600
0
$186.38
$186.38 2/18/16
KAY HENSEL
1042
2/8/2016
49275 AVENIDA EL
2/8/2016
ESG
STRUC TO ESGIL - 2ND P/C DUE BACK 2/22/2016
OUTSIDE PC
NIDO
PLAN CHECK SUBMITTAL
BSAS 581473 FEE
101-0000-20306I
1 0
$1.00
$1.00
1
2/18/16
1
R13026
1
1042
1
MARY FASANO
49275 AVENIDA EL
1
1/15/2016
1/15/2016
RECEIVED
NIDO
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $1.00
BSA:
RESIDENTIAL, EA
101-0000-42403
0
$36.99
$36.99
CALLED MARK CHILD TO INFORM HIM THAT HE HAS
TELEPHONE CALL
JIM JOHNSON
CHECK
1/29/2016
SKH
1/29/2016
NIDO
CORRECTIONS.
TELEPHONE CALL
JIM JOHNSON
0
2/18/2016
$15.24
2/18/2016
R13026
CALLED MARK TO INFORM HIM PLANS ARE READY TO ISSUE
CHECK
49275 AVENIDA EL
SKH
ADDITION 1,000SF, PC
ly I Zd4��X
NIDO
-vl
101-0000-42403
0
$145.03
F $145.03
2/18/16
NAME TYPE
NAME
ADDRESS1
CITY STATE
ZIP PHONE FAX EMAIL
APPLICANT
MARK CHILD
NIDO
CONTRACTOR
OWNER BUILDER
OWNER _I
MJ3 LLC / LMH REALTY INC
80215 VIA VALEROSA
LAQUINTA
CA
92253
. . . . . . . . . . . . . . . . . . . . . . . .
CLTDBY
DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY
HOURLY PLAN CHECK -
101-0000-42600
0
$186.38
$186.38 2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
ESG
NIDO
Total Paid for BLDG CITY STAFF - PER HOUR: $186.38 $186.38
BSAS 581473 FEE
101-0000-20306I
1 0
$1.00
$1.00
1
2/18/16
1
R13026
1
1042
1
CHECK
1
49275 AVENIDA EL
1
SKH
NIDO
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $1.00
BSA:
RESIDENTIAL, EA
101-0000-42403
0
$36.99
$36.99
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
ADDITION 1,000SF
NIDO
RESIDENTIAL, EA
101-0000-42600
0
$15.24
$15.24
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
ADDITION 1,000SF, PC
NIDO
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
F $145.03
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
1,OOOSF
NIDO
Printed: Friday, February 19, 2016 8:58:42 AM 2 of 5 CR&KYSTEMS
Printed: Friday, February 19, 2016 8:58:42 AM 3 of 5 cps"SYSTEMS
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
1,OOOSF, PC
NIDO
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $245.12 $245.12
APPLIANCE
101-0000-42402
0
$12.09
$12.09
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
REPAIR/ALTERATION
NIDO
APPLIANCE
101-0000-42600
0
$4.83
$4.83
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
REPAIR/ALTERATION PC
NIDO
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
NIDO
EXHAUST HOOD PC
101-0000-42600
'0
$4.83
$4.83
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
NIDO
Total Paid for MECHANICAL: $33.84 $33.84
FIXTURE/TRAP
101-0000-42401
0
$48.36
$48.36
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
NIDO
FIXTURE/TRAP PC
101-0000-42600
0
$48.36
$48.36
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
NIDO
GAS SYSTEM, 1-4
101-0000-42401
0
$12.09
$12.09
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
OUTLETS
NIDO
GAS SYSTEM, 1-4
101-0000-42600
0
$24.17
$24.17
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
OUTLETS PC
NIDO
WATER SYSTEM
101-0000-42401
0
$12.09
$12.09
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
INST/ALT/REP
NIDO
WATER SYSTEM
101-0000-42600
0
$12.09
$12.09
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
INST/ALT/REP PC
I
I
I
INIDO
Total Paid for PLUMBING FEES: $157.16 $157.16
REMODEL,EA
101-0000-42400
0
$174.00
$174.00
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
ADDITIONAL 5000 SF
NIDD
REMODEL, EA
101-0000-42600
0
$139.20
$139.20
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
ADDITIONAL 500 SF PC
NIDO
Printed: Friday, February 19, 2016 8:58:42 AM 3 of 5 cps"SYSTEMS
a Tom•
OF
Permit DetIls�
City of La Quinta
PERMIT NUMBER
BR -5 I f Lff
�'v�� �{ �, icy?'- .r`4 -e 3 �' '.a�r 5 % �, %' ,• { ..r � � V ,`:k .:.'„S- { � ; � � A 3 "T , 1 .a -+i j y. i.�e:,4 .-. f i.wi.� �.
•
RETURNED STATUS REMARKS
REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES
DATE
-#'I
JIM JOHNSON
1/15/2016
1/29/2016
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT
CHECK #
METHOD
PAID BY
WK)
2ND BLDG NS (2
JIM JOHNSON
BY
2/22/2016
2/16/2016
APPROVED
WK)
49275 AVENIDA EL
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
2/18/16
R13026
1042
CHECK
REMARKS: Transfer notes in red ink to set(s) at
SKH
READY FOR APPROVAL
the City. On sheet A1.3 cross out foundation plan
KURT CULVER
NIDO
2/22/2016
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$134.88
2/18/16
R13026
1042
CHECK
49275 AVENIDA EL
SKH
PC
numbers S-1.1 and S-1.2 to sheets 11 and 12.
NIDO
Total Paid for REMODEL: $497.39 $497.39
49275 AVENIDA EL
SMI - RESIDENTIAL
101-0000-20308
FO
1 $1.95
$1.95
2/18/16
R13026
1042
CHECK
SKH
NIDO
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.95 $1.95
�'v�� �{ �, icy?'- .r`4 -e 3 �' '.a�r 5 % �, %' ,• { ..r � � V ,`:k .:.'„S- { � ; � � A 3 "T , 1 .a -+i j y. i.�e:,4 .-. f i.wi.� �.
•
RETURNED STATUS REMARKS
REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES
DATE
1ST BLDG NS (2 WK)
JIM JOHNSON
1/15/2016
1/29/2016
1/29/2016
REVISIONS REQUIRED
1ST BLDG STR (2
KURT CULVER
1/15/2016
1/29/2016
1/27/2016
REVISIONS REQUIRED
WK)
2ND BLDG NS (2
JIM JOHNSON
2/8/2016
2/22/2016
2/16/2016
APPROVED
WK)
REMARKS: Transfer notes in red ink to set(s) at
2ND BLDG STR (2
READY FOR APPROVAL
the City. On sheet A1.3 cross out foundation plan
KURT CULVER
2/8/2016
2/22/2016
2/16/2016
WK)
_ CONDITION
and note to see S-1.1 instead and added sheet
numbers S-1.1 and S-1.2 to sheets 11 and 12.
BOND INFORMATION
Printed: Friday, February 19, 2016 8:58:42 AM 4 of 5
U U LJ U SYSTEMS
Printed: Friday, February 19, 2016 8:58:42 AM 5 of 5
&
CRSYSTEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
1ST REVIEW
BRES2016-006 -1ST
DOC
1/27/2016
AJ ORTEGA
STRUCTURAL FEE SHEET
REVIEW STRUCTURAL
0
(ESGIL)
FEE SHEET.pdf
1ST REVIEW
BRES2016-006 - 1ST
DOC
1/27/2016
AJ ORTEGA
STRUCTURAL
REVIEW STRUCTURAL
.0
CORRECTIONS (ESGIL)
CORRECTIONS.pdf
2ND REVIEW
BRES2016-0006 - 2ND
STRUCTURAL
REVIEW STRUCTURAL
DOC
2/16/2016
AJ ORTEGA
TRANSMITTAL
TRANSMITTAL
0
(APPROVED-
(APPROVED-
CONDTIONS)
CONDTIONS).pdf
49-275 AVENIDA EL
49-275 AVENIDA EL
DOC
1/29/2016
JIM JOHNSON
NIDO.docx
NIDO.docx
0
OWNER BUILDER 2-19-
OWNER BUILDER
DOC
2/19/2016
STEPHANIE KHATAMI
16
BRE2016-0006.pdf
0
Printed: Friday, February 19, 2016 8:58:42 AM 5 of 5
&
CRSYSTEMS
erA
' Bin # 1,
City of La. Ouinta
Building 8F Safety Division' ,
Permit-# Ol Jam.-�'r ` . 78-495 Calle Tampico-
ampico La Quinta, CA 92253 - (760) 777-7012
La
Building Permit Application and Tracking.Sheet
Project Address:�4Q Z, ? �� /'t (J��/e//�+'� wner's Namo .'�' {� - z-7
A. P. Number: �p �J — 2 / — �� •� ,3 - —
Address: ' Y/%4 r/Lfl. e/40,*+
Legal Description4,p% 1/,T 7-1 7 ' L &e
City, ST, Zip:
Contract 0
G� ra
Telephone: one: %
now
Address: 10 O 2 / d6 VAS LP*ojeet
Description: • • -
,���
city, ST, Zip: K%i4 w
Telephone:
e hon
P Gv G
_
State Lic. # : City Lie. #;
Arch., Engr., Designer:D2.//Gi/r4
Address:
City, ST, Zip: moi" Qu . rA
.!t'
Te le ho v.7 �S
a i #• __
State Lac.
ontt
CstFuc on TYPeOccupancy:
r Jeet tYPa (circle one). NewP Add'n Repair Demo
ame of Contact P son: J'//gYl Jz 'Y/L.0Sq.
Ft�,�a'��p
I4'stories: J
# Units: J
Telephone # of Co tact Person: ... ZJZ �J''►
Estimated Value of Proje
~ APPLICANT: DO NOT RITE BELOW THIS LINE
#
Submittal
Req'd `
Rcc'd
!TRACKING
PERMIT FEES
Plan Sels'
Plan Check submitted
Item
Amount
Structural Cafes.
Reviewed, ready for corrections
Plan Check Deposit
Truss.Calcs.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2nd Review, ready for. corrections/issue
Electrical'
-
Subconbctor List
Called Contact Person
-
Plumbing `
Grant Deed
Plans picked up '
S.M.L.
H.O.A. Approval
Plans resubmitted
Grading
IN IIOUSE:-
'"! Review, ready for corrections/issue
-
Developer Impact Fee
Planning Approval
Called Contact Person `" -
A.I.P.P:
Pub. Wks. Appr
bate of permit issue
r
_
�scl,00l Fees,
;
Total Permit Fees '
}
t .
-
.!t'
}
La Quinta Golf Estates
Community Association
Architectural Committee
P.O. Box 553
La Quinta, CA 92247
(760) 564-0136
jimandjgynew@verizon.net
January 13, 2016
Mr. Mark Child
49-275 Avenida El Nido
La Quinta, CA 92253
Dear Mr. Child:
The Architectural Committee for the La Quinta Golf Estates Community Association has
reviewed the plans that you submitted for your improvements at 49-275 Avenida El Nido
and we have approved them. We were impressed by the scope of the improvements and
we feel that they will improve the appearance of the home.
Please remember that the approval is for these plans only and if you make changes to
your plans they will have to be resubmitted for approval.
Yours truly,
UL
immie D. Woods
Chairman, Architectural Committee
SAN 15 2010
0F QUINI T
CN p�VEt-CPM
EN
COMMUN�N
211 't
y . +.-- ... ..... �.. .,� �-J �.� � i� U;.w r ' t .,�., •:Jas° '.•.,.. .. „•w -•a. - •-f :fy .�. ,
Building Permft Number. A:
Project Description. Improvement/Remodel
Exempt: o -
f,, t ,; (Materials may contain hazardous wastes and
am 9 _ are not subject to recycling provisions) +;
oF. - Construction,Debris Management Plan ,
Plan Submittal Date 1/11/2016 {
Job Site Address + 49275 Avenida EI Nido,' La Qulnta CA'' "
f Owners Name Mark Child
Number, Street, or PO Box •80215 Vla Valerosa
' rr City, state, Postal code , La_Quinta, CA. 9+2253 -
i
t ° Owners Phone Number _
t Owners E -Mail Address . - p •,
Project Managers Name Mark Child r ;
Project Managers Phone Number RE(, ,,,, a �
E.
Project Managers E-mail A_ ddres's
' Builder/Contractor Mark Child/Owner-Builder '".4" • t• JAN 15 2016
Number, Street or PO Box 80215 Via Valerosa ;
City, State, Postai Code I La Quinta, CA. 92253 3 =CITY OF LA QUINTA
Tn` COMMUNITY DEVELOPMENT
Project Square Footage 4,250�square feet - ».
`City Approval BYA'�.�1Q�ee..
I Date of City Approval col `J / /1140,
Materials 7o Be Discarded: t
Product —Tons "
Trash 4.50 Not recyclable , Product Tons'
I Asphalt 0.00 Recyclable ;r-, r
'`Masonry (broken) 0.00 Recyclable -
y Brick/Block 0.00 RecyclablePlaster 0.00 Recyclable
...
Cardboard ' . 0.00 Recyclable : - `Scrap Metal 0.00 Recyclable t
Commingled 0.00 Recyclable Tile (floor) .0.00 Recyclable
Concrete 5.00 Recyclable ' • ; 'Tile (roof) 0.00 Recyclable r '
Drywall "1.25 Recyclable t - Wood '0 00 Recyclable R.
Donated / Reuse* 0.00 Recyclable .-,Landscape Debris • 0.00 Recyclable '
r 'Describe Items
Totals: Rec cle Trash - Projected Diversion: .
6.3
I understand it Is the property owners responsibility to submit copies of weight tickets or receipts to the District
x Environmental Coordinator as these hauls occur:. I hereby certify that completion, Implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsfte waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining '
materials generated from the first day of the project through the completion of the project In accordance with this plan. This
DMP Is Issued In the name of the property owners) and shall remain their property throughout the construction and/or
demolition project A contractor serving as agent of the ovdner may obtain a DMP for the owner. However, the DMP is still -
issued In the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bl-monthty, reports. If se"auling, all refuse material from this project site must be taken to an approved recycler or transfer
w Owner / Developer / Project Manager L Superintendant q F Date ,
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CAiLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
(760)777-7012
FAX (760) 777-7011
PROPERTY OWNER'S PACKAGE
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! .NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building peimit has been submitted in your name listing yourself as the builder of th property
improvements specified at '� %_-5- - Z_�� ��/ �� j
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
V ♦•L\L'n .i y.-�.vvvi.r,i,�lvir,i�1 A1VL VERIkICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signs you understand or verify this information.
.1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not'provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on/my property.
V2. I understand building permits are not required to be signed by property owners unless they'are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
understand as an "Owner -Builder" I am the responsible sp party of record on the permit I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his of her name instead of my
own.
4. I understand Contractors are required bylaw to be licensed and bonded in California and to list their license numbers on
permits and contracts.
_45. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be.considered an "employer"
under state and federal law.
6. I understand if I am considered an "employer" under state and federal law, I must register, with the state and federal
v
goernment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
.risk.
7_1 understand under California. Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with .the intent to offer :them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or.all.of the work is performed
under contract with a licensed general building Contractor.
R
L8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any ! ,
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
149. I understand I may obtain more information regarding my, obligations as an "employer" from the Internal Revenue
Service, the United States Small.Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
_10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party. a lly : and fiially responsible fo _ prop coctiory activity at the following address:
711. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner -Builders as.well as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information 1
ave provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and. wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note. A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature. /
Signature of property o Date:
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply far a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign; and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note. A copy of the.owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owners signature.
Property Owner's Signature: Date:
CITY OF LA QUINTA SUB -CONTRACTOR_ LIST
JOB ADDRESS `�`7Z 2 /'t�c�li��i L2�- 'f4OPERMIT NUMBER _,a5,?01G "CM:'OWNER_M J3 L LC/ ILP F4 1MSY UILDER
This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response.
r:.
�accifira+.nn -: f`nntractbr: State:.Gnntractor.a License workers Comriensation..Insurance ::. .. _... Crty:Bu ......
smess License
M4SONRY:(C-29`)'.;:,:;.. :.
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx)
Exp. Date
(xx/xx/xx)
UNI.BING (C 36)
/
%� fc [r �dG.
�;O
C/ �j
d l n l�
b
EONCRETEIC8)........
r6r�
,�
/j
(
�d��
- N'
�V
Z ��
UC, -D
a
FRAMING (C 5)
G c�`lt�/ _
���
/ 3/ /�
`r5rVU�'-b1.1Yi�
��in�l��`1��t/l��i�i'
��
tic 600Z�l�
fag ��
M4SONRY:(C-29`)'.;:,:;.. :.
Company Name Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
UNI.BING (C 36)
/
%� fc [r �dG.
�;O
C/ �j
d l n l�
b
LATH ;:PLASTER (C 35)
QS!d7'����•— ��Y�
�
C� s�(o8�
/�/%/f
/
'. LECT;RICAL (C 10.1;:
'�T1411
(NS CO O� lt�Ii��
uJ�D �DU �0`'I ✓
113'J ((�
�� e on oar
�13f�(�
::ROOFING (C 39) ::
�.. /�i/'7� til^ %�—'
7��C� .�l
/iii/i�J
if I%W
ITY OF LA QUINTA SUB -CONTRACT T /
JOB ADDRESS tae �� ��i�R NUMBER ��2�i� �30WNER d' `, �?�—.. _ DER
This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this lis or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response.
PraHe_/:C�l: siit. catinrti .:.. C nntr9c-torr StatA.Cnntractnr sLicense Wnrkarc.:G0.inoensatton..lnsilr.anc2' City. usineSS ilCenSe
Exp. Date
(xx/xx/xx)
Company Name Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx)
Exp. Date
(xx/xx/xx)
J
J%W
Y
c BUILDING ENERGY ANALYSIS REPORT
- : PROJECT:
Child Residence Remodel
49-275 Avenida EI Nido
La Quinta, CA 92253
Project Designer:
Brian De Coster Design.and Drafting
PO BX 1.654
` 1a Quinta, CA 92253•
• (760) 771-6569 -
_ Report Prepared by: .
r .Tim Scott
Scott Design and Title 24, .Inc,`
r _ 77085 Michigan. Drive
Palm Desert, CA 92211 `
(760) 200-.47 CITY OF LA QUANTA
BUILDING '& SAFETY DEPT.
APPROVED
t FOR CONS RUCTION
_ # t DATE 2016&
f r
: Job Number:
- . r JAN 15 2016 -
- Date cI?Y of LA quiNTA
DEVELOPMENT
•
=11/114/2016
The EnergyPro computer program has been used to'perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft,'LLC—,www.energysoft.com.
Ene77yPro 7by Enery Solt User Number. 6712 ID:
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016
Calculation Description: Title 24 Analysis Input File Name: Child Res Remodel-deCoster-15.xml
CF1 R -PRF -01
Page 1 of 9
GENERAL INFORMATION
01
Building Complies with Computer Performance
01
Project Name Child Res. Remodel
03
This building incorporates one or more Special Features shown below
02
Calculation Description Title 24 Analysis
08 -
Energy Use (kTDV/ft2-yr)
03
Project Location 49-275 Avenida EI Nido
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 3971
15
Number of Zones 1
16
Slab Area (ft2) 3971
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 0
21
Glazing Percentage (%) 17.3%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
06
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-14 17:26:46
ENERGY USE SUMMARY
04
05
06
07
08 -
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.08
2.23
-0.15
-7.2%
Space Cooling
138.42
131.45
6.97
5.0%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
8.65
8.65
0.00
0.0%
Photovoltaic Offset
--
0.00
0.00
--
Compliance Energy Total
149.15
142.33
6.82
4.6%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-14 17:26:46
- -
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016 Page 2 of 9
Calculation Description: Title 24 Analysis - Input File Name: Child Res Remodel-deCoster-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
- Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below. ,
Building -level Verifications:
— None —
Cooling System Verifications: ! .Y
•
—None — 3 r
HVAC Distribution System Verifications:
— None — i
Domestic Hot Water System Verifications: ,
. _ None -
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy. Design;Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 187.87 11811.015, ' . 6.82 3.6%
"includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING -FEATURES INFORMATION
, -
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Child Res. Remodel
3971
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Res.
Conditioned
HVAC 11
3971
10
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version = CF1R-08252015-744 Report Generated at: 2016-01-14 17:26:46
z+'
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Child Res. RemodelCalculation Date/Time: 17:25, Thu, Jan 14, 2016 Page 3 of 9
Calculation Description: Title 24•Analysis Input File Name: Child Res Remodel-deCoster-15.xml
OPAQUE SURFACES. -
01
02
03 i
04
05
06
07
08
09
10
Name
i Zone r
Construction
Azimuth
Orientation
Gross Area (ft2)
Window 8 Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
N Vali
Existing Res..—
R-19 Wall (W.19.2x6.16)
0
Right
972
140
90
Existing
No
E Vali
Existing Res.
R-19 Wail (W.19.2x6.16) •
90
Front
981
222
90
Existing
No
S Wall
Existing Res.
R-19 Wall (W 19.2x6.16)
180
Leff
972
38
90
Existing
No
SWWall
Existing Res.
R-19 Wall (W1 9.2x6.16)
225
135
40
14
90
Existing
No
,. WWall,
Existing Res.
RA9 Wall (W19.24.16)•
270
Back
1011
258
90
Existing
No
NW Wall ' •
Existing Res.
R-19 Wall (W 19.2x .16)_
315
225.
40 `
14
90
Existing
No
a, Roof-
Existing Res.
R-38 Roof Attic
3971
Existing
No
ATTIC < -
01
02
03
0405
06
07
08
09
10
>
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
'Roof Reflectance
Roof Emittance
Barrier •
Cool Roof
s
Condition
' Attic Existing Re's`. ;
Attic RoofExisting Res.`
Ventilated • .
3 -
0.1
0.85
No
No
Existi
No'
}
ng
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016
Calculation Description: Title 24 Analysis
Input File Name: Child Res Remodel-deCoster-15.xml
CF1 R -PRE -01
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
N-4X6f
N Wall (Right -0)
-
--
1
24.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5f
N Wall (Right -0)
--
--
1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N-0X8fd
N Wall (Right -0)
----
---
1
48.0
0.32
0.25
Insect Screen (default)
New
N/A
E-4X1.5s
N Wall (Right -0)
--
---
1
6.0
0.58
0.53
Insect Screen (default)
Existing
No
E-4X1.5s 2
N Wall (Right -0)
--
---
1
6.0
0.58
0.53
Insect Screen (default)
Existing
No
E-4X5s
N Wall (Right -0)
--
--
1
20.0
0.58
0.53
Insect Screen (default)
Existing
No
E-4X1.5s 3
N Wall (Right -0)
--
--
1
6.0
0.58
0.53
Insect Screen (default)
Existing
No
N-6X2f
E Vali (Front -90)
---
--
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5s
E Vali (Front -90)
----
--
1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X2f 2
E Wall (Front -90)
--
---
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5s 2
E Wall (Front -90)
--
---
1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N6X5s
E Wall (Front -90)
-
--
1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
E-2X4f
E Vali (Front -90)
--
--
1
8.0
0.35
0.30
Insect Screen (default)
Existing
No
E-2X4f 2
E Wall (Front -90)
----
--
1
8.0
0.35
0.30
Insect Screen (default)
Existing
No
E-2X4f 3
E Wall (Front -90)
---
---
1
8.0
0.35
0.30
Insect Screen (default)
Existing
No
N-0X8fd 2
E Wall (Front -90)
6.0
8.0
1
48.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X6s
E Wall (Front -90)
6.0
6.0
1
36.0
0.32
0.25
Insect Screen (default)
New
N/A
N-4X2f
S Wall (Left -180)
--
--
1
8.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5f 2
S Wall (Left -180)
--
--
1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N-2X2f
SW Wall (- specify -225)
--
--
1
4.0
0.32
0.25
Insect Screen (default)
New
N/A
N-2X5f
SW Wall (- specify --225)
----
---
1
10.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X2f 3
W Wall (Back -270)
--
----
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-0X8fd 3
WWall (Back -270)
--
---
1
48.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X2f 4
W Voll (Back -270)
6.0
2.0
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5s 3
W Wall (Back -270)
6.0
5.0
1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X2f 5
W Wall (Back -270)
6.0
2.0
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X8fd 4
W Wall (Back -270)
6.0
8.0
1
48.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X2f 6
W Voll (Back -270)
6.0
2.0
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X2f 7
W Wall (Back -270)
6.0
2.0
1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2016-01-1417:26:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016
Calculation Description: Title 24 Analysis Input File Name: Child Res Remodel-deCoster-15.xml
CFI R -PRF -01
Page 5 of 9
N-6X2f 8
W Wall (Back -270) 6.0
2.0 1
12.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5s 4
W Wall (Back -270) —
-- 1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N-6X5s 5
W Wall (Back -270) ----
-- 1
30.0
0.32
0.25
Insect Screen (default)
New
N/A
N-2X2f 2
NW Wall (- specify --315) ----
--- 1
4.0
0.32
0.25
Insect Screen (default)
New
N/A
N-2X5f 2
NW Mll (- specify --315) ----
-- 1
10.0
0.32
1 0.25
1 Insect Screen (default)
New
N/A
OVERHANGS AND FINS
0.1 02 03 04 05 06 07 08 09 10
11 12 13 14
Overhang Left Fin
Right Fin
I Window s Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht. Depth
Top Up Distl- Bot Up
Depth
Top Up
Dist R
Bot Up
N-6X8fd 2 10
0.1
10
10
0 0
0 0 0
0
0
0
0
N-6X6s 10
0.1
10
10
0 0
0 0 0
0
0
0
0
N-6X2f 4 6
0.1
6
6
0 0
0 0 0
0
0
0
0
N-6X5s 3 6
0.1
6
6
0 0
0 0 0
0
0
0
0
N-6X2f 5 6
0.1
6
6
0 0
0 0 0
0
0
0
0
N-6X8fd 4 6
0.1
6
6
0 0
0 0 0
0
0
0
0
N-6X2f 6 6
0.1
6
6
0 0
0 0 0
0
0
0
0
N-6X2f 7 6
0.1
6
6
. 0 0
0 0 0
0
0
0
0
N-6X2f 8 6
0.1
6
6
0 0
0 0 0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Cavity / Frame: no insul. 12x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting Res.
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing., Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/ Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -19/2x6
• Exterior Finish: Wood
R-19 Wall (W 19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
0.069
Siding/sheathing/decking
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2016-01-14 17:26:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016
Calculation Description: Title 24 Analysis Input File Name: Child Res Remodel-deCoster-15.xml
CFI R -PRF -01
Page 6 of 9
SLAB FLOORS
01
02
03
04
06
06
07
08
09
Name
Zone
Area (W)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab i
Existing Res.
3971
366
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) . Quality installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required --
WATER HEATING SYSTEMS
01
02
03 :.
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
2
Annual
Existing
No
WATER HEATERS
01 t F
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1 '
Natural Gas
Small Storage
50
0.6 EF
40000-Btu/hr
0
0.03
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
i
i•. '
Registration Number: - Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2016-01-14 17:26:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016
Calculation Description:•Title 24 Analysis Input File Name: Child Res Remodel-deCoster-15.xml
CFI R -PRF -01
Page 7of9
SPACE CONDITIONING SYSTEMS l; i
01
,02
4 03
04
05
06
07
08
09
10
Multi -speed
Heating System
Cooling System
System Type -
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1..
SplitAirCond - Split air conditionig
n
1,1
13
Distribution
Fan
Floor AreaVerified
Location
Existing
Name
System Type
Name a Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC 11,
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3971
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS !
( 01 02 03
Name Type Efficiency
i Heating Component 1 CntrlFurnace Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS ,
01
02
03 - 04
05
06
07
07
_
Efficiency
10
Multi -speed
Verified Duct Location
Name
System Type -
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1..
SplitAirCond - Split air conditionig
n
1,1
13
No
No
N/A
Location
system
Status
Condition
Verification
=Air Distribution
System 1
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS -
i
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
—
_ —
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
=Air Distribution
System 1
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
--
—
_ —
o -
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-14 17:26:46
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. Remodel Calculation Date/Time: 17:25, Thu, Jan 14, 2016
Calculation Description: Title 24 Analysis Input File Name: Child Res Remodel-deCoster-15.xml
CF1 R -PRF -01
Page 8 of 9
IAQ (Indoor Air Quality) FANS -
01 02 03 04 05
Name IAQ CFM IAQ_ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Child Res. RemodelCalculation Date/Time: 17:25, Thu, Jan 14, 2016
a
Calculation Description: Title 24 Analysis Input File Name: Child Res Remodel-deCoster-15.xml
CF1 R -PRE -01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT -
L -I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: '
Documentation Author Signature:
Tim Scott
Company: a
Signature Date:
Scott Design and Title 24, Inc,
1/14/2016
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/StatePalm Desert, CA 92211
Phone:
200-4780
(760)
RESPONSIBLE PERSON'S DECLARATION STATEMENT
certify the following under penalty of perjury, under the laws of the State of California:,
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
'2 - . I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3:. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Brian De Coster
Company:
Date Signed:
Brian De Coster Design and' Drafting
'
Address:
License:
PO BX 1654
City/State/Zip:
Phone:
La Quinta, CA 92253
(760) 771-6569
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2016-01-14 17:26:46
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Child Residence Remodel
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/14/2016
Project Address
49-275 Avenida El Nido La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,971
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Roof Wood Framed Attic
R 38 3,971
Existing
Wall Wood Framed
R 19 3,330
Existing
Slab Unheated Slab -on -Grade
-
no insulation 3,971 Perim = 366'
Existing
FENESTRATION
Orientation Area(ft2)
Total Area: 686 Glazing Percentage: 17.3 %
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor:
Exterior Shades
0.32
Status
Right (N) 102.0
0.320
0.25 none none
Bug Screen
New
Right (N) 38.0
0.580
0.53 none none
Bug Screen
Existing
Front (E) 114.0
0.320
0.25 none none
Bug Screen
New
Front (E) 24.0
0.350
0.30 none none
Bug Screen
Existing
Front (E) 84.0
0.320
0.25 10.0 none
Bug Screen
New
Left (S) 38.0
0.320 0.25 none none
Bug Screen
New
Left (SVV) 14.0
0.320 0.25 none none
Bug Screen
New
Rear (VV) 120.0
0.320 0.25 none none
Bug Screen
New
Rear (IM 138.0
0.320 0.25 6.0 none
Bug Screen
New
Rear (NW) 14.0
0.320 0.25 none none
Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
2 Central Furnace
80% AFUE
Split Air Conditioner 13.0 SEER
Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling 'Duct Location
Duct
R -Value Status
HVAC 1 Ducted
Ducted Attic
4.2
Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro, 6.7 by EnerqySoft User Number. 6712
RunCode: 2016-01-14T18:31:13
ID:
Page 12 of 24
200 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may aDply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 1 i0.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC), and infiltration that meets the requirements of §10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minim= R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class It vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class U
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class lI vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8( ).
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tigbt-fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ 150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.0(j)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
203 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
--
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced au duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy _5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ 150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
200 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§I 10.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch.that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ 150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§150.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § I50.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)lC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§ 150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if. it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable re uirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or. vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically tum the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
1
ii. Shall comply with the applicable requirements in § l 10.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
§ 150.0(k)9D:
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§150.0(k)1l:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § 110.10(e).
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
-local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§110.16(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system. - -
§110.10(d): 110.10(d):
A copy of the construction documents or a comparable document indicating the information from §1 10.10(b) through §110.10(c)
shall be provided to the occupant.
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Child Residence Remodel
Date
1/14/2016
System Name
HVAC 1
Floor Area
3,971
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
2,989
662
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 89,000
44,493
4,484
1,365
47,584
Total Output (Btuh) 178,000
0
Output Btuh/s ft 44.8
3,773
3,381
Cooling System
0
0
Output per System 57,800
24,732
6,125 662
31,840
Total Output (Btuh) 115,600
0
3,773
1 76,770
10,609
0
Total Output (Tons) 9.6
3,381
Total Output (Btuh/sgft) 29.1
Total Output (s ft/Ton) 412.2
86,185
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
4,000
Existing HVAC
91,823
15,795
178,000
Airflow (cfm/sgft) 1.01
Airflow (cfm/Ton)
415.2
Outside Air (%)
16.5%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
91,823
15,795
Aug 3 PM
178,000
Jan 1 AM
Outside Air (cfm/sgft) 0.17
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICSAirstream
Tem 'eratures atTiine of Heating Peak)
26 OF 64 OF
�.
Outside Air
662 cfm Supply Fan
4,000 cfm
71 OF
64 OF 106 OF
Heating Coil
��^---�--
105 OF
ROOM
i
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 83 / 68 OF 83
Outside Air
662 drn - Supply Fan
4,000 cfm
77 / 66 OF
/ 68 OF 61 / 60 OF
Cooling Coil
_ ..
62 160 OF
56.9% ROOM
76165 OF
EriergyPro 6.7 by EnergySoR User Number. 6712 RunCode: 2016-01-14718:31:13 ID:
Page 17 of 24
ZONE •AD SUMMARY
-.
Child Residence Remodel
111412016
System Name
1
FloorDate
3,971
ZONE LOAD SUMMARY
SYSTEM NAME
(BLOCKHVAC
LOAD)
ROOM LOAD SUMMARY
Project Name Date
Child Residence Remodel 1/14/2016
System Name Floor Area
HVAC 1 3,971
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible LatentCM Sensible Latent CFM Sensible
Existing Res. Existing Res. Zone 1 2,9891 44,4931 4, 484 [2ZE989 44,4931 4,484 1,3651 47,584
' Total includes ventilation load for zonal systems.
EnefgyPro 6.7 by EnefgySoft User Number. 6712 RunCode.
PAGE TOTAL
TOTAL*
Z 989 44,493
4,4841
1,365
47,584
2989 44,493
4,484
1,365
47,584
!016-01-14718:31:13 ID:
ROOM HEATING PEAK LOADS
Project Name -
Child Residence Remodel
Date
1/14/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Res. Zone
Floor Area 3,971.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry'Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X.
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
=
=
=
_
=
=
-
-
=
=
_
=
-
=
_
=
-
=
=
_
=
46
Btu/hr
R-38 Roof Attic
3,971.0
0.0260
46
4,749
R-19 Wall (W. 19.2x6.16)
3,330.0
0.0740
46
11,335
Low-E dooNwindow
624.0
0.3200
46
9,185
Double Non-Metal Tinted
38.0
0.5800
46
1,014
Double Metal Tinted
24.0
0.3500
46
386
Slab-On-Grade
perim = 366.0
0.7300
46
12,290
_.
-
-
_.....
r
-
—
_
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule .Air Sensible
Fraction
through an interior surface
X 3,971 X
Area _
another room
10.00 X 0.266
Height ACH
Page Total
/60] X
AT
38,960
= 8,624
TOTAL HOURLY HEAT LOSS FOR ROOM 47,584
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode:.2016-01-14T18:31:13 ID: Page 20 of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Child Residence Remodel 1 1/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Existing Res. Zone
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,971.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
76 OF 1
Outdoor Daily Range:
34 OF
Opaque Surfaces
R-38 Roof Attic
R-19 Wall (W. 19.2x6.16)
R-19 Wall (W. 19.2x6.16)
R-19 Wall (W. 19.2x6.16)
R-19 Wall (W. 19.2x6.16)
R-19 Wall (W. 19.2x6.16)
R-19 Wall (W. 19.2x6.16)
Orientation
(W)
(N)
(E)
(S)
(SW)
(►M
(NW)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
3,971.0
0.0260
56.0
832.0
0.0740
23.0
759.0
0.0740
33.0
934.0
0.0740
26.0
26.0
0.0740
31.0
753.0
0.0740
33.0
26.0
0.0740
6.0
31.3
188
0.0
31.3
6.0
31.3
188
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
N-4X6f
N-6X5f
N-6X8fd
E-4X1.5s
E-4X1.5s
E-4X5s ..
E-4X1.5s
N-6X2f
N-6X5s
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(E)
(E)
Btu/hr
5,782
1,416
1,853
1,7971
60
1,839
58
1 12,8051
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+'
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
Btu/hr
0.0
15.7
24.0
15.7
376
0.0
15.7
30.0
15.7
470
0.0
15.7
48.0
15.7
752
0.0
31.3
6.0
31.3
188
0.0
31.3
6.0
31.3
188
0.0
31.3
20.0
31.3
625
0.0
31.3
6.0
31.3
188
0.0
15.7
12.0
30.5
366
0.0
15.7
30.0
30.5
916
Page Total
4,069
Internal Gain Btu/hr
Occupants 11.9 Occupants X 245 Btuh/occ. = 2,919
Equipment 3,971 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.88 X 181.98 X 36 = 6,161
Air Sensible CFM EIA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 44,493
Latent Gain Btu/hr
Occupants 119 Occupants X 155 Btuh/occ. = 1,847
Infiltration: 4,771 X 0.88 X 181.98 X 0.00344 = 2,637
_ Air Sensible CFM EIA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.8471
I EnergyPro 6.7 by EnemySott User Number.- 6712 1 RunCode:.2016-01-14718:31:13 ID: Page 21 of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name TDate _
Child Residence Remodel 1/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing Res. Zone Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,971.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temaerature 76 OF Outdoor Dailv Rancie: 34 OF
Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X,
CLTD'
=
=
=
=
=
=
=
=
_
Btu/hr
0.0
15.7
30.5
366
0.0
15.7
30.5
916
0.0
15.7
30.5
916
0.0
18.1
35.9
288
0.0
18.1
+
8.0
X
35.9
288
0.0
18.1
+
8.0
X
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
N-6X2f
N-6X5s
N6X5s
E-2X4f
E-2X4f
E-2X4f
N-6X8fd
N-6X6s
N-4X2f
Orientation
(E)
(E)
(E)
(E) .
(E)
(E)
(E)
(E)
(S)
Btu/hr
Shaded
Area
X
X
X
X
X
X
X
X
X
GLF
Unshaded
Area
+ 12.0 X
+ 30.0 X
+ 30.0 X
+ 8.0 X
GLF
=
=
=
=
=
=
=
=
=
Btu/hr
0.0
15.7
30.5
366
0.0
15.7
30.5
916
0.0
15.7
30.5
916
0.0
18.1
35.9
288
0.0
18.1
+
8.0
X
35.9
288
0.0
18.1
+
8.0
X
35.9
288
47.4
15.7
+
+
+
0.6
X
X
X
30.5
761
36.0
15.7
0.0
30.5
564
0.0
15.7
8.0
15.7
126
Page Total
4,512
Internal Gain " Btu/hr
Occupants 11.9 Occupants X 245 Btuh/occ. = 2,919
Equipment 3,971 Floor Area X 0.50 w/sem = 6,777
Infiltration: 1.064 X 0.88 X 181.98 X 36 = 6,161
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 44,493
Latent Gain Btu/hr
Occupants 119 Occupants X _ 155 Btuh/occ: = 1,847
Infiltration: 4,771 X 0.88 X 181.98 X 0.00344 = 2,637
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM. 1.847
I Ener-gyPro 6.7 by EnergySoft User Number 6712 RunCode: 2016-01-14T18:31:13 ID: Page 22 of 24 1
e
e
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Child Residence Remodel 1 1/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing Res. Zone Outdoor Dry Bulb Temperature 112 OF
Floor Area 3, 971.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 76 OF Outdoor Daily Ranqe: 34 OF
ue Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
_
0.0
15.7
+
30.0
15.7
=
0.0
15.7
+
4.0
21.4
=
=
0.0
15.7
+
10.0
21.4
0.0
15.7
+
+
+
+
+
12.0
30.5
=
0.0
15.7
48.0
30.5
=
=
12.0
Page Total
Items shown with an asterisk (•) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fenestration
N-6X5f
N-2X2f
N-2X5f
N-6X2f
N-6X8fd
N-6X2f
N-6X5s
N-6X2f
N-6X8fd
Orientation
(S)
(SIA9
(SIA9
(IM
(IM
(IM
(IM
(IM
nM
Shaded
Area
X
X
X
X
X
X
X
X
X
GLF
Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
0.0
15.7
+
30.0
15.7
=
0.0
15.7
+
4.0
21.4
=
=
0.0
15.7
+
10.0
21.4
0.0
15.7
+
+
+
+
+
12.0
30.5
=
0.0
15.7
48.0
30.5
=
=
12.0
15.7
0.0
30.5
28.2
15.7
1.8
30.5
=
12.0
15.7
0.0
30.5
=
28.2
15.7
+
19.8
Page Total
Btu/hr
Btulhr
472
86
214
366
1,465
188
497
188
1,046
4, 523
Internal Gain Btu/hr
Occupants 11.9 Occupants X 245 Btuh/occ. = 2,919
Equipment 3,971 Floor Area X 0.50 W/sgft
Infiltration: 1.064 X 0.88 X 181.98 X 36 = 6,161
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 44,493
Latent Gain Btu/hr
Occupants 119 Occupants X 155 Btuh/occ.� = 1,847
Infiltration: 4,771 X 0.88 X 181.98 X 0.00344 = ' 2,637
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,847
I EnergyPro 6.7 by EnergySoft User Number., 6712 RunCode: 2016-01-14T18:31:13 ID: Page 23 of 24 1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Child Residence Remodel
1 1/14/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Existing Res. Zone
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,971.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
N-6X2f
(1/109 12.0 X 15.7 +
0.0
X 30.5 =
188
N-6X2f
(1/109 12.0 X 15.7 +
0.0
X 30.5 =
188
N-6X2f
(1/109 12.0 X 15.7 +
0.0
X 30.5 =
188
N-6X5s
(lM - 0.0 X 15.7 +
30.0
X 30.5 =
916
N-6X5s
AM 0.0 X 15.7 +
30.0
X 30.5 c
916
N-2X2f
(MA09 0.0 X 15.7 +
4.0
X 23.7 =
95
N-2X5f
(NM 0.0 X 15.7 +
10.0
X 23.7 =
237
X +
X =
X +
X =
-
Page Total
2,728
Internal Gain
Btu/hr
Occupants
11.9 Occupants X 245
Btuh/occ.
=
2,818
Equipment
3,971 Floor Area X 0.50
W/sgft
=
6,777
Infiltration: 1.064
X 0.88 X 181.98 X 36 =
6,161
Air Sensible
CFM ELA � AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
44,493
Latent Gain .
Btu/hr
Occupants
11 9 Occupants X 155
Btuh/occ.
=
1,847
Infiltration: 4,771
X 0.88 X 181.98 X 0.00344 =
2,637
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,847
Ene Pro 6.7 by Ene Soft
User Number. 6712 RunCode: 2016-01-14718:31:13 ID:
Page 24 of 24