Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0202
L_ 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tw�t 4 4 Qum& COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSOL2015-0202 Property Address: 43695 CALLE ESPADA APN: 609580002 Application Description: MOFIDI / 9.15kW PV SYSTEM - (28) 327W PANELS/(2) INVERTER Property Zoning: Application Valuation: $28,000.00 Applicant: PLANET SOLAR INCORPORATED 719 E HALEY STREET SANTA BARBARA, CA 93103 35 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION -DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations: 9 (commencing with Section 7000) of Division 3 of the Business and Profe Code, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: B. C46 License No.: 938313 of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Date: s Contractor Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044,.Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Carrier:— Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, ifll should become subject to. th workers' compensation provisions of Section 3700 of the Labor Code with comply with those provisions. Date: L/6z Applicant* WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of.this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buil ing construction, and hereby authorize representatives of this city to enter upon above-menti�rty for inspection purposes. • Date: Signature (Applicant or•Agent Date: 11/9/2015 Owner: CHARLES LEE 43695 CALLE ESPADA F LA QUINTA, CA 92253 cc © ¢a o cV =z Contractor: © C3 w S g PLANET SOLAR INCORPORATED o Q 719 E HALEY STREET �`iv� O E= v117-1 SANTA BARBARA, CA 93103 j (805)692-2700 Llc. No.: 938313 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION -DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations: 9 (commencing with Section 7000) of Division 3 of the Business and Profe Code, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: B. C46 License No.: 938313 of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Date: s Contractor Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044,.Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Carrier:— Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, ifll should become subject to. th workers' compensation provisions of Section 3700 of the Labor Code with comply with those provisions. Date: L/6z Applicant* WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of.this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buil ing construction, and hereby authorize representatives of this city to enter upon above-menti�rty for inspection purposes. • Date: Signature (Applicant or•Agent FINANCIAL •• • DESCRIPTION' ACCOUNT QTY AMOUNT .. PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # ! CHECK # CLTD BY DESCRIPTION ACCOUNT QTY 'AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $24.17 $0.00 PAID BY - METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL: $96.68 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:•0 00 8.829 kW DC PV SYSTEM AZIMUTH: 90', 180' (28) SUNPOWER MODULES: 327W PV MODEL#: SPR-327NE-WHT-D MODULE DIM: 61.39" X 41.18" MODULE WEIGHT: 41 lbs INVERTER MODEL#: POWER ONE, PVI4.2-OUTD-S-USA(24OV)/SPR4201 P -TL INVERTER QTY: 02 PV STRUCTURE: TILE TRAC ATTACHMENTS W/ UNIRAC SUPPORT RAIL ROOF TYPE: GABLED, SQUARE TILE NUMBER OF STORIES: 01 ROOF TILT: FLUSH PANEL TILT: 15' ROOF FRAMING: 2"x6" ROOF RAFTERS: 24" O.C. SPACING STRUCTURE TYPE: SFR NUMBER OF ROOFS UTILIZED: 02 INVERTER A: (2) STRINGS OF 07 MODULES INVERTER B: (2) STRINGS OF 07 MODULES FIRE CLEARANCES ADHERED AS PER SECTION R331.4.2 OF 2013 CBC 3'-0" FROM RIDGE & EDGE 1'-6" FROM VALLEYS ROOF ACCESS AS — PER SECTION R331.4.1 OF 2013 CBC NOTE: PHOTOVOLTAIC SYSTEM CONDUCTO S SHALL BE IDENTIFIED AND GROUPED. THE MEANS Cf IDENTIFICATION SHALL BE PERMITTED BY EjEEAEATE _ COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMIILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC SECTION 690.4(B)) NOTE: PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC SECTION 690.4(E)) PHOTOVOLTAIC INSTALLATION PLAN SCALE: I"=20' JUNCTION BOXES IN SERVICE PANEL VICINITY MAP PROJECT LOCATION .11695 CaIM f ero�a V�.'(VcJc 2 o vr� 14 - :DISCONNECT SCOPE OF WORK THIS PROJECT CONSISTS OF THE INSTALLATION OF (28) PV SUBPANEL PHOTOVOLTAIC MODULES AND (02) UTILITY INTERACTIVE INVERTERS. INSIDE GARAGE PV MODULES WILL BE MOUNTED TO AN EXISTING RESIDENTIAL 01 GABLED SQUARE TILE ROOFTOP USING TILE TRAC ATTACHMENTS TITLE SHEET WITH UNIRAC SUPPORT RAIL. INVERTERS 02 0 INSIDE GARAGE THE ATTACHMENT SYSTEM IS SPECIFICALLY DESIGNED TO WITHSTAND 0 r 11OMPH WIND LOADS AND SEISMIC LOADS ON EXISTING ROOFTOPS. �A P7 5 6 REFER TO CODE COMPLIANT INSTALLATION MANUAL FOR DETAILED PHOTOVOLTAIC MODULE DATA SHEET INVERTER DATA SHEET ATTACHMENT DATA SHEET INFORMATION AND WATER PROOFING SPECIFICATIONS. ATE // A<- CONbUITSI3/4" EMT ON ROOF UNDER EAVE/ IN ATTIC PROJECT JURISDICTION II PREPARED FOR: CITY OF COUN IY: ADDRESS: CITY, STATE,ZIP PH: DE C CITY OF LA QUINTA 78-495 CALLE TAMPICO LA QUINTA, CA, 92253 760-777-7125 ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. PV SYSTEM SPECIFICATIONS TLE TRAC SUNPOWER PV 4.2-.11--S-USA(240 ATTACHMENTS HMENTS R-327NE-WHT-D 28 FSPR -4201P -TL 02 UNIRAC RAIL 15 9g0 8.829kW NODULE QTY. INFERTER D- RA-- TILT A2INDTN DC R0+/ER RATItN (STC i m mac ARRAYS INDEX SHEET NO. INDEX NO. DESCRIPTION: W zV I 0 M w = 01 T-1 TITLE SHEET JFSHEET ClATASHEET ' OF LA QUI 02 0 M-1 E-1 PHOTOVOLTAIC EQUIPMENT PLAN SINGLE LINE DIAGRAM 0 r ING & SAP SAFETY D p®`/� �A P7 5 6 D-1 D-2 D-3 PHOTOVOLTAIC MODULE DATA SHEET INVERTER DATA SHEET ATTACHMENT DATA SHEET 0 O R CONSTRUCTIO 8 D-� WARNIRAIL DNG PLACARDS ATE // A<- CONbUITSI3/4" EMT ON ROOF UNDER EAVE/ IN ATTIC PROJECT JURISDICTION II PREPARED FOR: CITY OF COUN IY: ADDRESS: CITY, STATE,ZIP PH: DE C CITY OF LA QUINTA 78-495 CALLE TAMPICO LA QUINTA, CA, 92253 760-777-7125 ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. PV SYSTEM SPECIFICATIONS TLE TRAC SUNPOWER PV 4.2-.11--S-USA(240 ATTACHMENTS HMENTS R-327NE-WHT-D 28 FSPR -4201P -TL 02 UNIRAC RAIL 15 9g0 8.829kW NODULE QTY. INFERTER D- RA-- TILT A2INDTN DC R0+/ER RATItN (STC i m mac w O M Ljj 0 N W CN W W zV I 0 M w = Q � p � wV) w Q�r7 LLJ w J U Lu z v _Qar�i W pCJ_F- �NaLd Q N 0 r F O L w;E (oC3 < LLJ (o ap0DDoor- 0 O I w O I p N Q m F - Q w Q�r7 p oo�Q� 7:_ v I �NaLd Q N Z p < LLJ (o ap0DDoor- 0 O I DQE I r7 a_ c_) _. Ld w z CD 12/23/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgtt T-1 1 1 w_@5M09% TKI TRAC. AS;SMIU RAFTS CONNECTION DETAIL ROOF LOAD CALCULATION ROOF: 28 PANELS PENETRATION SPACING: 72" MAX PV AREA SINGLE MODULE: 16.56 SQ. FT. PV AREA TOTAL: 463.68 SQ. FT. PV PANEL WEIGHT = 41 lbs MOUNTING HARDWARE WEIGHT=10 lbs/pone) ENTIRE WEIGHT ON ROOF: (41 IDS, ponels)x(28)+ (10 IDS, structure)x(28)= 1428 IDS [ 1148+280] 1428 lbs/463.68 sq.ft.= 3.08 Ibs/sqft GBL GROUNDING LUGS USED PER 2013 CEC 690.43, UL 2703 LISTED FIRE CLEARANCES ADHERED AS PER SECTION R331.4.2 OF 2013 CBC 3'-0" FROM RIDGE & EDGE 1'-6" FROM VALLEYS • 1 ATTACH MODULES TO / STRUCTURE PER DETAILS AND DATA SHEET EXISTING 2X6 PV LAYOUT PLAN RAFTERS 1 SCALE: 3/32" = 1'-0" ® 24 O.C. PV ATTACHED W/TILE TRAC ATTACHMENTS AND UNIRAC SUPPORT RAIL. REFER TO DATA SHEETS FOR WIND AND VERTICAL FORCE DESIGN CHARACTERISTICS 15' CLAY 2X6 WOOD TRUSS � 24"O.C. —� RIDGE BOARD '=11" 37 PANEX RAILS JUNCTION BOXES 0`3/- S. -Oe FROM EAVE TO GROUND :Z1 ROOF SECTION PLAN N.T.S. MAIN SERVICE PANEL AC DISCONNECT PV SUBPANEL INSIDE GARAGE INVERTERS INSIDE GARAGE CITY OF LA QUINT, BUILDING & SAFETY DEPT o P�'R®VE® CONSTRUCTION DATE 11W11 _. _ it 3/4" E.M.T. ON ROOF/UNDER EAVE/ IN ATTIC 0 w_lv; 1 -:14 F_1IthIm= CLASS 1 - DIVISION 1 METALLIC CONDUIT W/NO JOINTS 3'-0' PH I �+p Q TO ARRAYS GAS IGRADE MAIN SERVICE ELEVATION GENERAL NOTES: 1. CONDUIT RUNS ARE DIAGRAMMATIC. SUBJECT TO FIELD CONDITIONS AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET NEC REQUIREMENTS. .2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL BUILDING AND ELECTRICAL CODES. 3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITH STAND 110 MPH WIND -LOADS. REFER TO RACKING DATASHEET. 4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND UNDERSTANDING THE SECTION OF THE INVERTERS OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE SAFETY AND PROPER INSTALLATION. 5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. 6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE. 7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8, LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHT RESISTANT. 9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES PV SYSTEM SPECIFICATIONS TRAC SUNPOWER PV14.2-oum-s-USA(2ao ATTACHMENTS 90' R-327NE-WHT-D 28 /SPR -4201P -TL 02 UNIRAC RAIL 15 180' 8.829kW MODULE QTY. Iwwem+ an. I RACIORD III T AZIR111R D0 POWER )UTINI (sTc 1:7 z OUTSIDE I.- nn®� OY< INSIDE GARAGE Q) (N) AC UTILITY DISCONNECT I V (E) MAIN SERVICE (N) SUBPANEL J PANEL ( N) INVERTER M LLi � W< N �—j 1 V 1 1 NUD_N 3'-0' PH I �+p Q TO ARRAYS GAS IGRADE MAIN SERVICE ELEVATION GENERAL NOTES: 1. CONDUIT RUNS ARE DIAGRAMMATIC. SUBJECT TO FIELD CONDITIONS AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET NEC REQUIREMENTS. .2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL BUILDING AND ELECTRICAL CODES. 3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITH STAND 110 MPH WIND -LOADS. REFER TO RACKING DATASHEET. 4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND UNDERSTANDING THE SECTION OF THE INVERTERS OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE SAFETY AND PROPER INSTALLATION. 5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. 6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE. 7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8, LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHT RESISTANT. 9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES PV SYSTEM SPECIFICATIONS TRAC SUNPOWER PV14.2-oum-s-USA(2ao ATTACHMENTS 90' R-327NE-WHT-D 28 /SPR -4201P -TL 02 UNIRAC RAIL 15 180' 8.829kW MODULE QTY. Iwwem+ an. I RACIORD III T AZIR111R D0 POWER )UTINI (sTc 1:7 z da 0 it I.- nn®� OY< Q) �J z - 0 I V J 0- M LLi � W< N NUD_N LQwV W �inwU7 CL H z�QQ,d) Q — U O W z t0 D O O rn 0 0 a w co Lu d I I I O I >�v I 0)m Q < Of (r �I O = U Q �L) W = Of M zQ(n�20 <9ujn US awoo0^ I omm MaL w I 0 w z U V) 12/23/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELUNG: SFR. 2737sgft m-1 2 GENERAL NOTES, (4) PV ARRAYS 1. IF SERVICE PANELS DO NOT HAVE EXISTING GROUNDINGELECTRODE.INSTau A SUPPLEMENTHE TAL (4) STRINGS OF. 07 GROUNDING ELECTRODE. 2. 16 BARE COPPER GROUND TO BE ATTACHED TO EACH r -550 hmi MODULE DIRECTLY VIA GROUND LUGS AND ATTACHED MODULES TO EACH RAIL WITH LUGS 3. EACH SOLAR MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE PER THE MANUFACTURER'S INSTRUCTIONS. ® PV (2) Be EGC INVERTER (N)AC UTILITY (E) SERVICE PANEL DISCONNECT -- 5 + � (1) OGModules 1 ® eoNo TO CHASSIS (TYP.) (1) ECC I (N) ATTACH NEW GEC TO EXISTING BY IRREVERSIBLE MEANS Al Bodo TO (TV.)F PV ARRAY INFORMATION VALUE DESCRIPTION Module Wattage 327W Input data from PV Module data sheet Number of Modules 28 Total Modules for PV system Module (VOC) 64.90V Input data from PV Module data sheet P Module (VMP) 54.70V Input data from PV Module data sheet Module (ISC) 6.46A Input data from PV Module data sheet Module (IMP) 5.98A Short circuit data from PV Module data sheet Max Voc of Inverter 600V Input data from Inverter data sheet Inverter PPTV Range 125 - 500V 9 Voltage from data sheet Peak Power Trackin 9 77' Average high temperature 'F 29' Record low temperature 'F per Branch 7 Module string configuration Number of Branches 2 , 2 Module string configuration Branch VOC 454.3V Module Voc x Number of Modules per Branch Branch VMP 382.9V Module Vmp x Number of Modules per Branch Branch ISC 12.92A Module Isc x Number of Branches VERALL SYSTEM AMPR 38.33A 920OW/240V=38.33A GROUNDING DETAIL PV SYSTEM VALUES - _ - - - - LE WATTS) X (8 OF MODULES IN ARRAY) PV SYSTEM VOLTAGE - (VOC VOLTS) X (8 OF MODULES) X CEC FACTOR CIRCUIT CURRENT - CEC FACTOR X (TOTAL SYSTEM WATT/ TOTAL SYSTEM VOLT) INVERTER AC POWER OUTPUT - (MAX AC POWER OUTPUT) SERVICE VOLTAGE - (110/24OV) CIRCUIT CURRENT - CEC FACTOR X (MAX INVERTER AC POWER/240) PV ARRAY 1 O 1 STRING OF 07 1 PV ARRAY 2 1 STRING OF 07 1 PV ARRAY 3 1 STRING OF 07 O PV ARRAY 4 O 1 STRING OF 07 1 (327 X 07) - 2289 WATTS (64.90 X 07) - 454.3VOLTS x 1.14 - 517.9V < 600V INVERTER MAX VOLTS, complies 1.25 X (2289/454.3)= 6.4 AMPS x 2 strings - 12.8A - LOAD TO INVERTER c 32A. vstem carnslies SYSTEM 9200 WATTS 240 VOLTS 1.25 X (9200/240) - 47.92 AMPS 1.25 X (4600/240) - 23.96 AMPS 1.25 X 20A max inverter output - 25 AMPS msp rated 200A X 1209 = 240A The Sum: mcb derated to 175A + 50A = 225A System Complies, the Sum did not exceed 1209 X 2 Inverters - 50 AMPS MAX combined WIRE CHART NEC 310.15f9If3NA) ACTUAL B6AWG 090C - 75A x temp deration of 80% for 4 conductors 60A > 50A. system complies f10AWG 090C - 40A x temp deration of 80% for 4 conductors 32A > 25A, system complies PV SOURCE CIRCUITS (4) 810 USE -2 PV WIRE - POSITIVE (4) 810 USE -2 PV WIRE - NEGATIVE (4) 86 BARE CU (GNO) 11 1 SINGLE LINE WIRING DIAGRAM SCALE: N.T.S. ' PVI4.2-OUID-S-USA $PR4201P-TL J -BOX 0 PV14.2-0IftD-S-USA / SPR4201P-TL J -BOX 810 THWN-2 - POSITIVE 810 THWN-2 - NEGATIVE 88 THWN-2 (GND) 3/4- EMT CONDUIT 200A MAIN PV SOA CITY OF LA QUIN" BUILDING & SAFETY DEI APPROVED FOR // /�S�C�ONSTRUCTI ON IATIM (W116 OV PV SUB PANEL 125A/ 240V MAIN SERVICE PANEL �25 (E) 200A, MCB DERATED TO 175A GENERAL NOTES 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE 3. INTERMODULE WIRING-DURASHEATH LOW -VOLTAGE POWER, UNSHIELDED, EPR, HYP, VOLTS: 60OVDC• U.L TYPE RHH/RHW-2/USE-2 CONDUCTOR SIZE (AWO/KE)WIL) 10, RATED AT 90- WET OR DRY WITH MULTI -CONTACT LOCKABLE CONNECTORS 4. ANY OC WIRING RUNS IN THE INTERIOR OF THE HOME SHALL BE RUN IN A METAL CONDUIT OR RACEWAY AND CLEARLY MARKED 'CAUTION OC -CIRCUIT' EVERY 5 FEET PER CODE REQUIREMENTS S ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. 6. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 7. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING. IT IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A NEW SUPPLEMENTAL GROUNDING ELECTRODE. 8. USTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(8) 9. PROVIDE WARNING SIGN PER NEC 690.17 READING 'WARNING -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS - terminals ON BOTH UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION.' 10. LABEL 'PHOTOVOLTAIC UTILITY INTERACTIVE INVERTER' AND 'WARNING POTENTIAL ARC FLASH HAZARD CAN CAUSE SHOCK. BURN. OR DEATH.' 11. LABEL 'PV SYSTEM UTILITY DISCONNECT SWITCH' SWITCH COVER TO BE LOOKED AT ALL TIMES SWATCH TO BE VISIBLE BLADE AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22 12. LABEL BREAKER 'PHOTOVOLTAIC ELECTRIC POWER SOURCE' PER NEC 705.10 AND 'BREAKERS ARE BACKFED' PER NEC 690.64(BX5) 13. ALL MODULES WLL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS 14. LABEL 'CAUTION' SOLAR CIRCUIT SHALL BE ON ALL EXPOSED CONDUIT, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES AND ALL AC CONDUIT ON MICRO -INVERTER SYSTEMS 15. SEE DERATING PLACARD AND 'LOAD CALCS TO BE FIELD VERIFIED BY INSPECTOR AT FIRST INSPECTION' 16. PV CONNECTION IN PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION. PV SYSTEM BOM ITEM: I DESCRIPTION: PHOTOVOLTAIC MODULES: SUNPOWER MODEL* SPR-327NE-WHT-D SURGE SUPPRESSOR - MNSPD-300, SEE INSTALLATION MANUAL PV 125A SUB -PANEL JUNCTION BOX NEMA 3R INVERTERS: POWER ONE PV14.2-OUTD-S-USA (240V) / SPR4201P-TL RESERVED AC UTILITY DISCONNECT SWITCH (60A, 240VAC, NEMA -3R) SYSTEM GROUND BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY COMPANY UTILITY METER 120/240VAC IO M �--� AC UTILITY DISCONNECT SWITCH I (N NMCB A V I 60A, 240V, NEMA -311 (f) LOADS lVirc 1/2" 3(4 QTY. 28 0 1 2 2 0 1 1 1 MAXIMUM NUMBER OF MODULE IN STRING: 07 OPERATING CURRENT: 11.96A OPERATING VOLTAGE: 382.9V MAXIMUM SYSTEM VOLTAGE: 454.3V MAXIMUM SHORT-CIRCUIT CURRENT: 12.92A [IIIIIIIIIIIIINJ --� �- Size EMT EMT I EMT I EMT I EMT I EMT Ter 3 - 50A 3/4' EMT CONDUIT O 810 THIN (1) 3/4' EMT CONDUIT 88 THIN -22 (GND) (3) 86 THWN-2 (I) 86 THWN-2 (CND) (1) 3/4' EMT CONDUIT (3) 86 THWN-2 (1) 86 THWN-2 (GND) 1 i 14 12 1 27 12 9 it 101 S IC 8 3 6 6 Z 4 d 1 2 3 1 1 1 2 1 1 1 1 Typical AWG wire sizes ..I G.xnf',r luf4e I I 4aJ ,r:�a;,w'P aiax�• "`r: v.�cvo AJ _ I�1:mni .5u l)I�a,v 1 ;,a i �1e-rh,�--� a•�,�y.�� v"no��� I 1 1 I i_ I Ilf Ilt .a, 19iA� L(9 s-3 I f>,liz [- 1 :• I l f: � I ' It �_I f = m I ; ,ng11c s y= cp.l_loc r tG1 I__lrr.'• l-IhoI z 11- l.. to tA I- U') LJ ,3 I r+• LTJ Z W �p ~ LLi U Q N J FA Z LU 0 C) LJ J �w�V Z O Q Q M ►--4 41 Ln o 0 0) LU LO CT ~ r')_j I I O I �p c9 Iw- O) m Q Q I LLI IY O � V a I ♦-NOT LLJ LLIV))t0 I QZLa1M ED iI aooMr- 1 oho) C14 -j I r') a V I J I 0 Cil Z N 12/23/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft :E-1 3 20% EFFICIENCY SunPower E20 panels are the highest efficiency panels on the market today, providing more power in the some amount of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest - efficiency panels with the highest -efficiency inverters, maximizing system output REDUCED INSTALLATION COST More power per panel means fewer panels per instoll. "this saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique Moxeon"cell technology and advanced module design ensure industry-leading reliability MAXEONT6' CELL TECHNOLOGY Patented c1Ibc4A—_ontect so:cr cell, prov:ding the industry's h'ghest efi:ciency and relability IMODULE DATA SHEET 1 SCALE:N.T.S. Z SERIES THE WORLD'S STANDARD FOR SOLAR'" SunPower7" E20 Solar Panels provide today's highest efficiency and performance. Powered by SunPower Maxeon"' cell technology, the E20 series provides panel conversion efficiencies of up to 20.1 %. The E20's low voltage temperature coefficient, onfi-reflective glass and exceptional low -light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 205/o `- 15% 10% 5% SFRIES SERIES SEPiES sunpowercorp.com C UL OS MODEL: SPR-327NE-WHT-D ELECTRICAL DATA e.W.ud a Lv.d:d :x C.:Nrem P:'.7 +wdw. cl IDGWS'/n=. A!x. t S; ad..t tnvia^e.: S' C Peak Power 1+5/,3*,' Pmax 327 W Cell Efficiency n 22.5% Panel Efficiency n 20.1% Rated Voltage V,,,pp 54.7 V Rated Current I,nPP 5.98 A Open Circuit Voltage VOC 64.9 V Short Circuit Current IX 6.46 A Maximum System Voltage UL 600 V Temperature Coefficients Power (P) - 0.38%/K Voltage (Voc)-176.6mV/K Current (lu) 3.SmA/K NOCT 45'C ./- 21 C Series Fuse Rating 20A Grounding Positive grounding not requited MECHANICAL DATA Solar Cells 96 SunPower Moxeon' cells Front Gloss High•tronsmission tempered gloss with anti -reflective (AR) coating Junction Box IP -65 rated with 3 bypass diodes Dimensions: 32 x 155 x 128 mm Output Cables 1000 mm cables / Muf6Conroa (MC4) connectors Frome Anodized aluminum alloy type 6063 (black) Weight 41.0 lbs 118.6 kg) 14.1. IA)-N.OUNSL'2G HOLES 19) . G40UND"G Kota IC41 12X 036.6 1^61 TOX 00.21.171 - I-V CURVE 7 1000 wr.d or W t 6 t000w/mr 5 Z 4 emr 3 u' 2 tww,r 1 2W W/m° 0 0 10 20 30 40 50 60 70 Voltage M t.ucr.rh0i.' Ue ch.m. .vr w,b dopeade --.d,- .di- cnd mo4.Ae ran;.aavr. TESTED OPERATING CONDITIONS Temperature -40* F to +185' F (- 40" C to + 85° C) Max load 113 psi 550 k9/m2 15400 Po), front le.g. snow) w/specified mounting configurations 50 psi 245 kg/m2 (2400 Po) front and back (e.g. wind) Impact Resistance Hail: (25 mm) of 51 mph (23 m/s) VVARRANTIES AND CERTIFICATIONS Warranties 25yeor limited power worronty 10year limited product warranty Certifications Tested to UL 1703. Class C Fire Paling DIMENSIONS I aJ ENDS _i It �1 19� 1 1 r - 1 Please read safety and installation instructions before.using this product, visit sunpowercorp.com for more details. C2011&rP—Capvma. UQVa':.'EP e-s,.r....boo, a.d ME u'aryp'S SLIJDAMfOR SCIO..dr AXRXIa,.r A.-6v,.D;.w.d. d.,,,,h sunpowercorp.com d SnPaw Copvsiaw 66.1G and dr.m.aAt NGLs Peu.J.D1 C..•Ei^'_tr I� M0 o� W3< �06 Z C W W (n LLI M W Q N a WLjV) W O p W d' /Q LLJ L,J ZWQQM UZ(�a W J W o0^ �rn LU (D I I j04�v I N W �a)m Q Q V) O JO Ua� I rn U) J o: N Z Z M 0 Q Z W to co, a 0 n O�rT j. 00 J r-3 U I J Ww Z U U) 9/23/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft D-1 4 The most common residential inverter is the ideal size for an average - sized family home. This family of single-phase string inverter complements the typical number of rooftop solar panels, allowing home -owners to get the most efficient energy harvesting for the size of the property.This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. One of the key benefits of the Uno family of single-phase inverters is the dual input section to process two strings with independent MPPT especially useful for rooftop installations with two different orientations (ie East and West).The high speed MPPT offers real-time power tracking and improved energy harvesting. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. a 3000 l ,r+o�ro gg 3600 40OW 40OW 3300 3800 4200' lwa,aa N•,RM• _ ....urertas • Each inverter is set on specific grid codes which can be selected in the field is Single phase output • Dual input sections with independent MPPT, allows optimal energy harvesting from two sub -arrays oriented in different directions • Wide input range • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range • Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions • Integrated DC disconnect switch in compliance with international Standards (-S Version) • RS -485 communication interface (for connection to laptop or datalogger) • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI -DESKTOP • Integrated Arc Fault Detection and Interruption (-A Version) INVERTER DATA SHEET 1 SCALE: N.T.S. Maximum Output Power Rated Grid AC Voltage Inpa t Side (DC) Number of Independent MPPT Channels Maximum Usable Power for Each Channel Absolute Maximum Voltage (Vmn) Start. Up Voltage (Wilart) Fun Power MPPT Valtage Range Operating 61PPT Voltage Range Maximum Current Manax) for both MPPT In Parallel Maxlmum Usable Current per Chantel Maximum Short Circuit Current LAnit per, Channel Number of Wbe Landing Terminals Per Channel Amy Wiring Termination Output Side (AC ) Grid Connection Type AdjustableVoltage Range (Vmin-Vmax) Grid Frequency Adjustable Grid Frequency Range Maximum Current (laanax) Power Factor' Total Harmonic Distortion At Rated Power Grid Wiring Termination Typo Protection Devices Input Reverse Polarity Protection Over -Voltage Protection Typo PV Array Ground Fault Detection Output Antl4slanding Protection External AC OCPD Rating Over -Voltage Protection Type Efficiency Maximum Efficiency CEC Efficiency Operating Performance Night Time Consumption Stand By Consumption Communication User -Interface . Remote Monitoring (1 xRS485 incl) Wired Local Monitoring (1 xR548S incl.) Wireless Local Monitoring Environmental Ambient Alt Operating Temperature Range Ambient Air Storage Temperature Range Relative Humidity Acoustic Noise Emission Level Maximum Operating Altitudowithout Denting Mechanical Specifications Endosurerating Cooling Dimens(om (H x W x D) Weight Shipping Weight Mounting System Conduit Connections' W 3000 3307 3300' 3600 40OW 40OW 3300 3800 4200' 4200 460D' 4600' V 203 240 277 208 240 277 208 240 277 208 240 277 LU 2 2 2 2 LLI to LJ 04 �UaN W 2000 LLJ DEW it 3000 3000 U) LJ 0 LLI _j 3000 a�aL) C5 V Wa 9 u G00110 LLI to C7 600 V Q 200 (adj.120.3501 I O aU i f CV W- NF - V JOQ(n_ 0 M U Q 160-530 W = W M 120.530 140-530 po00r- a 140•S30 r00iazu:_ I V O W Z to 0.7xvstart-SBO I>= gov) DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres A D-2 20 32 32 32 A 10 16 16 16 A 125 20.0 20A 20.0 2 pain Termehal block, Pressure Clamp, AWGIO-AWG4 IOPW Split- 10/2W 10n%V Split' IORW IO/PJ Spit- 10/2W 10/81 Spin IORW 0/311 013W 0/3W O/31V V 183228 211.264 244304 183.228 211.264 244.304 183-228 211.264 244.304 183.228 211 .t64 244304 Ha 60 Hz S760S Awl 143 143 12.0 172 16.0 16.0 16.0 160 16.0 20.0 20.0 20.0 > 0.995 % c2 Terminal bIodL Pressure Clamp A%vG 10 - A,JG4 Yes varistot 2 for each ctaanel Pre start-up Riso and dynamic GF01(Requires floating Arrays) Mem UL 1741AEE 1547 requirements A_ 20 20 1s 25 20 20 20 20 20 25 25 2s Varstor,2(L.-Lr/L.•G) 96.9 97 97 97 % 96 LV <0.6 <8 - 16 characters x 21'vnes LCO display ' AURORA -UNIVERSAL (opt.) PVI-US8•R548S_232 (opt.). PVFDESKTOP (optj PW OSKTOP (opt) vith PVFRADtOL.ADULE (WU IF CC) • 13 to+140 (•25 to +60) hnith derating aba.•e 122 (50) 'F r`Q .40 to 176 (•40 to+80) %RH 0.100 condensing db (A) (V m < 50 film) 6560120001 in (mm) Ib (141 Ib (lx31 OC Switch Rating{Por Contact) AN safety Isolation level Safety and EMC Standard Safety Approval Warr" Standard Warranty years Extended Warranty years Ava(lableModeh standard- Without DC Swtich and Wiring Box - Standard. With DC Switch and%Vidng Box With DC Switch, Wiring box and Arc Fault Detector and Interrupter 'Aa dna is sub)m to lunge wtdrout robe 'Gapib 4ty ertatkd at nom" AC trtuge and pith uAdmi OC pones ancab2 't•4Kn equgmzd frith oprlaul DC mritrh andJ7uing Boa . WAA 4X Natural Com•Mion 339 x 128 x$.7 (859 x 325 x 222) < 473 (213) < 60 (27.0) ,411 bracket Trade size KOs: Rea x 1/21 and Ria x 1.1/4; 3 places side. front rear) Side: (2) plugged 314* openings. RI Concemric EKOs 3W. 1' Back (4) Concern& EKOs 3/4, I 25/600 Transformerless (Floating Array) UL 1741, CSA. C222 N.107.1.01. UL 1993 UL 1699B. FCC Part 15 Class 8 ,CSA. 10 15&20 PA 3.0.OUTD•US PvL3b-0UTD_Us F%1.3"UTD-US aM142-0UTD-Us PVF3.0.OUMS-US PVI3b•OUTD•S-US P1.1.3B4UMS-US PV142-OUTDS-US P%3.0-OUfD-S-USA PVI36.OUTD-S•USSA PN•39.OUrD•SUSA PVI-42-OUi6iUSA Inz Mg h O -j n-� VJ z C We l..J r W LU V) QM LLI to LJ 04 �UaN �- LLJ DEW it U) LJ 0 LLI _j Z a�aL) C5 W Wa 9 u G00110 LLI to C7 Q I O aU i f CV W- NF - 0) a] Q QW (n r7 JOQ(n_ 0 M U Q In U) _j W = W M Z<Lr) QZ Wto tp po00r- a OMrn r00iazu:_ I � J I O W Z to 12/21/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft D-2 5 --]v If 'rjjjj�d Party 'r'oed Lab lA-00a 't't tnittP / T.iflf? ft►4 c�,<rfi'�st.a a , T� IeTtra cc fir lr ff �1 �•r professional R, p�oclu?�"� {aQS[SCSI �oo 1551 5, lone AW fl—a, GA 9SOCt3 more info - our ds at: Patera �i,T4b,029 w . 4 ► Tile Roof Structural. Attachment NEW STAINLESS STEEL TILE FLASHING ~i The patented TileTroioD attachment allows far a structural roof raft:r mnnedion with optimal attachment stud location adjustability. Design results in the best looking systems in the industry. 11 i . Tile,Trar ' for s-czi1-r,e TileT ac ` fm• flat. i carrcrete tiler collerete life ,. (G Tall Threaded Strrrii (4 77411 Tlareaded Strrdl) Pell # M B46 Part a TT -1914 Bewj%s of Tile:Ti-ac• • Easiest and lowest cost waterproof trio roof • includes Stainless Stool tile flashing and attachment Stainless Steel log bolt • over IS years of industry profaned single log • Aluminum and Stainless Steel components for bolt design maximum corrosion,resistance and strength. • 3'd party lob waterproof and load tested - Large roof surface contact area evenly • Compression sealed at undedayment and top distributes food of tile The Tile T,ac- DeSipi Structurally attaches to roof rafter and allows the rail. attachment stud to be located at the strongest point of the file (the crown) where water does not flow. r Without TileTrac"' With. TileTrac"` Water Flaw, "' Crown Sealed at top of fila— in 16 Valle Cy of flit Tile r' „1_- -C- '- of the Tile _/ (optitaum) Katter atlachad fo the tatter � ATTACHMENT DATA SHEET j SCALE: N.T.S. LY Sealed at -j WV -ndarlarmant Rafter TileTrac'M essembl +i structurally attached to the rafter Installation steps for both s -curve and flat concrete tile* STEP I: Select a tile in the area of the roof rafter. Step 4: Seal the initial file nail hole. Using a 3/16" drill bit and drill guide (ft -Drill), drill pilot hole along the rafter center STEP 2 Remove the life by pushing and pulling It is usually held in place by o small nail. Step S: Insert the lag bolt and washer through the TileTracco and apply fresh compatible sealant to the base. Step 7: After bolting the base to the roof, slide the upper carriage into the correct position under the crown of the tie. For flat file, side the upper carriage near the middle of the tile. Tip: of stud to nuts to #op' to roof work Step 10: Insert threaded stud through tile and hondaighten to engage with base. Bind two 3/8" nuts (included) using 9/16" wrenches and tighten. 'Not recommended for clay or slate tiles. Step 8: Replace the file by lining up the snap lines and mark the drill location accordingly. Step 11: Unbind nuts and remove from stud. Apply sealant around stud at life opening and compress with Stainless Steel flashing (included) until seated. STEP 3: Using an dedronic stud finder (recommended), or other means, locate the colter center. Mark a reference point on the file above. Step 6: Using a 1/2" sodcel, install the lag bolt until seated. Do not overtighten. The sealant should flew outward sealing any holes. 0 U4 6 Rola Hammer drill I a S se cid drill time. Step 9: Using o 1/2" carbide drill bit and ROTARY HAMMER DRILL in hammer mode, drill through the life. See online video at www.prosolor.com for details. Step 12 Fasten mil with lower and upper 3/8" nuts/washers as shown. OProfessional Solar ProdUCtS, fnc. IMar. 2011. TileTrac"is a regisrered trademark and covered Under Par. t5,746,029 tj- i I W a) m UlM Q Q LE U Q N cn r Z N ro w Q y�(gwU� ¢?LL' aoocol- Z Q Q M 0 C5 LU lQ to Ln r� r �0(�^ W �J r, J I Z W 1-4 �!—o U i I O a) m Q Q(n M Q 0M0< j F-N�U� zacLd ¢?LL' aoocol- o-rn C14 -j � aa_L I t r, J I W N DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft D-3 2 SolarMount Beam Connection Hardware SolarMount L -Foot Part No. 3D4000C, 3040000 Y ►X ( S, sol roc 'i �uc:Muf t Dimensions specified to inches unless noted � j /� f . ii"UIVIRA • L -Foot material: One of the following extruded aluminum alloys: 6005- T5, 005T5, 6105-T5, 6061-76 • Ultimate tensile: 38ksi. Yield: 35 ksi • Finish: Clear or Dark Anodized • L -Foot weight: varies based on height: -0.215 lbs (98g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized Solt UNIRAC documents L -Foot For the beam to L -Foot connection: • Assemble with one ASTM F593 %'-16 hex head screw and one ASTM F594 %"serrated flange nut • Use anti -seize and tighten to 30 ftabs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory NOTE: Loads are given for the L -Foot to beam connection only, be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load Ibis (N) Resistance Factor, Sliding, 2t 1766 (7856) 155 (3356) 2.34 1141 (5077) 0.646 Tension. Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Traverse. Xt 486 (2162) 1 213 (949) 2.28 323 (1436) 0.664 RAIL DATSHEET A 1 SCALE: N.T.S. :PUNIRAC SolarMount Beams Part No. 310132C, 310132C43, 3101680, 310168C-8, 3101680 310208C, 31020SC-8, 3102400, 310240C -e, 3102400, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area inz 0.676 1.059 Section Modulus (X -Axis) in' 0.353 0.898 Section Modulus (Y -Axis) in' 0.113 0.221 Moment of Inertia (X -Axis) in' 0.464 1.450 Moment of Inertia (Y -Axis) in" 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 Radius of Gyration (Y -Axis) in 0.254 0.502 SLOT FOR T -BOLT OR tV4" HEX HEAD SCREW _T 2X SLOT FOR BOTTOM CLIP 2.500 T1.316 SLOT FOR O 3/8" HEX BOLT 387 750 Y •X SolarMount Beam Dimensions specified in inches unless noted M LL Ln F- J jV LD L,;,• co i.� Z LU irrL Q Lj M WZ N M W GO taJ 0 W J Z <<-) W t�UZc�D 0���^ W g cD C'J H d J W o U �p N FW - 0) m Q W QNr) _ 0:r < I I _ � f—N�U� Zinn Q_Wr)S, a 0 0 Co ^ M Orn I r-) a � o W Z 0 N DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft D-4 7 JUNCTION BOX & CONDUIT RACEWAYS NEC 690.31(E)(3) — CONDUIT / ALL JUNCTION BOXES WARNING: PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) — UNDERGROUND SYSTEM JUNCTION BOXES WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE INERGIZED. DC DISCONNECTS NEC 690.14(4) GROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD DO NOT TOCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.35(F) UNGROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED. NEC 690.14(C)(2) PHOTOVOLTAIC DC DISCONNECT NEC 690.53 WARNING PLACARDS 1 SCALE: N.T.S. NEC 690.5(C) — GROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUND AND ENERGIZED NEC 690.35(F) — UNGROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED DC DISCONNECTS PRODUCTION METER AC DISCONNECTS ONLY AT METER LOCATION NEC 690.14(C)(2) PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM METER AC DISCONNECT NEC 690.54 NEC 705.12(D)(4) — ON A LINE SIDE TAP WARNING: DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM CITY OF LA QUINT BUILDING & SAFETY DEPT FOR FjoVSD CONSTRUCTION JUNCTION BOX Bit SY d -- MAIN SERVICE PANEL NEC 705.12(D)(7) — NEAR PV BREAKER WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE NEC 705.12(D)(4), 690.56(B) — ON PANEL COVER WARNING: DUAL POWER SOURCE POWER IS BEING SUPPLIED TO THIS PANEL FROM THE UTILITY AND A SOLAR PV SYSTEM. THE SOLAR PV DISCONNECT IS LOCATED: NEC 690.14(C)(2) — NEAR PV BREAKER PHOTOVOLTAIC AC DISCONNECT NEC 690.54 — ON PANEL COVER PHOTOVOLTAIC REQUIREMENTS PER CAUFORNIA ELECTRICAL CODE ARTICLE 690 1 THQA,,fiirlr(rRi MLI.bt 1,4111(bE'rEPv !n"I% M1741IT w'-u0n; 199". rl,Jr1 C'.� •, Ar Mil" tr1G 38+70r Cs'. F -EL ;?, I'f rlETFA r:r.1:; WI fll V,4111 LEI7F,:17irli I ErlFEfiECTis°'AE�Tlltf f'f51$T:,.'li f..,_li>fG�:I[I rt.:lfi l4l 51CTA'.ac F�q rrc fff.IDbtAEIlT I1Tii Ed�.'•Ctt3Ef•IC5l.E[Crut.Tlu•; •,!P1trl+.,p SIkInArt1S F':41T;:PAIL.lo tION f 0 D t rT f Epfio III ALL CAr Tt.t c 4vU11141,Sh;:l • U". F" APAIL N:UI rt1t4lr411r4 7;S' r::tt E!.'tU l.m—EFIIY, Fit, t;1.r4 ILSY.ITHAHITlLEIKRUM,r qf. Wl SPIr I'Nf) r11; f CF WFAII1TD rf51S1AtfT tt.lfl 16L. ``I 11 f [rFtllr7rt,7 r�M fr 11rFTIt ;vSILLErqL14.QGH7TI1:Ir it=11r IFP .I'I r.a1EL i'r jt'f.r':kE1 Q� <M g � U Q N w00) H2 Fn Lu . ,^ V Z,<<n z z w IJ Z rp z o00)o Q ~ J I I I I I I v ttyy��I 1– CN - �a)m Q Q UJ Cu/)) - ox U U) -j— UNHV. LLJ a N P Z 0 Q Z LLj at�OMr CINI -j I � tl L) I r` J I 0 w z 9/23/15 DRAWN BY: BPM APN: 609— 580— 002 LOT: 0.27 acres DWELLING: SFR, 2737sgft L-1 9 9'156 kW DC PV SYSTEM AZIMUTH: 90', 180' (28) SUNPOWER MODULES: 327W PV MODEL#: SPR-327NE-WHT-D MODULE DIM: 61.39" X 41.18" MODULE WEIGHT: 41 lbs INVERTER MODEL#: SMA AMERICA, SB4000TL-US-22 (240V)/SPR4002m INVERTER QTY: 02 PV STRUCTURE: TILE TRAC ATTACHMENTS W/ UNIRAC SUPPORT RAIL ROOF TYPE: GABLED, SQUARE TILE NUMBER OF STORIES: 01 ROOF TILT: FLUSH PANEL TILT: 15' ROOF FRAMING: 2"x6" ROOF RAFTERS: 24" O.C. SPACING STRUCTURE TYPE: SFR NUMBER OF ROOFS UTILIZED: 02 ,INVERTER A: (2) STRINGS OF 07 MODULES INVERTER R- (2) STRINGS OF 07 MODULES FIRE CLEARANCES ADHERED AS PER SECTION R331.4.2 OF 2013 CBC 3'-0" FROM RIDGE & EDGE 1'-6" FROM VALLEYS ROOF ACCESS AS — PER SECTION R331.4.1 OF 2013 CBC NOTE: PHOTOVOLTAIC SYSTEM CONDUCTO S SHALL BE IDENTIFIED AND GROUPED. THE MEANS CIF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMIILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC SECTION 690.4(B)) NOTE: PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC SECTION 690.4(E)) 1-) PHLOTOVOLTAIC INSTALLATION PLANE. scA D O r 9/23/15 VICINITY MAP i. DRAWN BY: BPM RECEIV AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. APN: 609-580-002 CITY 0F LA QUINTA V O PUILDINQ & SAFETY DEPT. NOV 0 2 2015 41 DWELLING: DWELLING: SFR, 2737sgft Vi APPROVED PV' SYSTEM SPECIFICATIONS r COMMUNITY DEVELOPMENT SUNPOWER PROJECT LOCATION 10NQ�.�1 28 SPR-327NE-WHT-D SB4000TL-US-22(240V) /SPR-4W� 02ATTACHMENTS UNIRAC RAIL . , 180' 9,156kW 1 WWULE Or. NVEAIER — RAOOIIC MLT -- a POWF i -R o o ^� AIN SERVICE PANEL C DISCONNECT SCOPE OF WORK THIS PROJECT CONSISTS OF THE INSTALLATION OF (28) PV SUBPANEL PHOTOVOLTAIC MODULES AND (02) UTILITY INTERACTIVE INVERTERS. FV MODULES WILL BE MOUNTED TO AN EXISTING RESIDENTIAL GABLED SQUARE TILE ROOFTOP USING TILE TRAC ATTACHMENTS WITH UNIRAC SUPPORT RAIL. w o 04 INVERTERS THE ATTACHMENT SYSTEM IS SPECIFICALLY DESIGNED TO WITHSTAND Lli LL! v a 04 w I? CL 0) r,) 11 OMPH WIND LOADS AND SEISMIC LOADS ON EXISTING ROOFTOPS. REFER TO CODE COMPLIANT INSTALLATION MANUAL FOR DETAILED uj U .= INFORMATION AND WATER PROOFING SPECIFICATIONS. Luz Q Q M J r - w O U z SHEET INDEX ' SHEET NO. INDEX NO. DESCRIPTION: P ARRAYS 01 T-1 T1TI F SHFFT 02 M-1 PHOTOVOLTAIC EQUIPMENT PLAN n3 E-1 SINGLE LINE DIAGRAM 04 D-1 PHOTOVOLTAIC MODULE DATA SHEET 05 D-2 INVERTER DATA SHEET I 06 D-3 ATTACHMENT DATA SHEET 07 D-4 RAIL DATA SHEET o 08 L-1 WARNING PLACARDS 0 0) Of W M O I 0OCQjQd � Cn In J f ):w PROJECT JURISDICTION w= w ' I JUNCTION BOXES z � o Z� Q_W r7 cp PREPARED FOR: CON UIT 3/4" EMTaJ 0 o Co ROOF ON UNDER EAVE/ 0:2 rn IN ATTIC CITY OF COUNTY: CITY OF LA QUINTA 00 a ttk: ADDRESS: 78-495 CALLE TAMPICO n o J CITY, STATE,ZIP LA QUINTA, CA, 92253 PH: 760-777-7125 w z c� CODE COMPLIANCE Cn NOTE: PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC SECTION 690.4(E)) 1-) PHLOTOVOLTAIC INSTALLATION PLANE. scA D O r 9/23/15 ED ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, DRAWN BY: BPM RECEIV AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. APN: 609-580-002 ^� V LOT: 0.27 acres NOV 0 2 2015 41 DWELLING: DWELLING: SFR, 2737sgft CITY OF LA QUINTA PV' SYSTEM SPECIFICATIONS T-1 COMMUNITY DEVELOPMENT SUNPOWER TRE TRA� 90' 28 SPR-327NE-WHT-D SB4000TL-US-22(240V) /SPR-4W� 02ATTACHMENTS UNIRAC RAIL 15• 180' 9,156kW 1 WWULE Or. NVEAIER — RAOOIIC MLT -- a POWF i -R PV ATTACHED W/TILE TRAC ATTACHMENTS AND UNIRAC SUPPORT RAIL. REFER TO DATA SHEETS FOR WIND AND VERTICAL FORCE DESIGN CHARACTERISTICS €.r 15' CLAY I 2X6 WOOD a TS 24 "S ' O. C. RIDGE BOARD -�` TILE TRA{ .. AS�� 9'-0` AVE RAFTER 4. FROM GROUND TO GROUND CONNECTION DETAIL N. ROOF LOAD CALCULATION ROOF: 28 PANELS PENETRATION SPACING: 72" MAX PV AREA SINGLE MODULE: 16.56 SQ. FT. PV AREA TOTAL: 463.68 SQ. FT. PV PANEL WEIGHT = 41 Ibs MOUNTING HARDWARE WEIGHT=10 lbs/panel 10' — 3" ENTIRE WEIGHT ON ROOF: (41 lbs, panels)x(28)+ (10 lbs, structure)x(28)= 1428 lbs [ 1148+280] /� 1428 lbs/463.68 sq.ft.= .Ot"tOF LA QUIN A BUILDING & SAFETY DEPT. GBL GROUNDING LUGS U D APPROVED PER 2013 CEC 690.43, FOR CONSTRUCTION UL 2703 LISTED DATE_____—_ --BY FIRE CLEARANCES ADHER AS PER SECTION R331.4.2 ----- - (TF ?013 3'-0" FROMM RIDGE &EDGE 1'-6" FROM VAI I FY.S Ex 25'-7// , --- - - - - i 13'-9 - I T rA ROOF SECTION PLAN N.T.S. MAIN SERVICE PANEL AC DISCONNECT PV SUBPANEL 3/4" E.M.T. ON ROOF/UNDER EAVE/ IN A I I IC AERIAL VIEW CLASS '1 - DIVISION 1 METALLIC CONDUIT W/NO JOINTS (N) AC UTILITY DISCONNECT (E) MAIN k(N) SUBPANEL SERVICE PANEL (N) INVERTERS 3'-0" PH 0 TO ARRAYS TV GAS GRADE MAIN SERVICE ELEVATION GENERAL NOTES: 1. CONDUIT RUNS ARE DIAGRAMMATIC,_ SUBJECT TO FIELD CONDITIONS AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET NEC REQUIREMENTS. 2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL BUILDING AND ELECTRICAL CODES. 3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITH STAND 110 MPH WIND -LOADS. REFER TO RACKING DATASHEET. 4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND UNDERSTANDING THE SECTION OF THE INVERTERS OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE SAFETY AND PROPER INSTALLATION. 5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. 6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE. 7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHT RESISTANT. 9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES PV SYSTEM SPECIFICATIONS TRASUNPOWER TILE CHM 901. 28 SB4oDOTL-US-22(2ao� 02ATTACHMENTS 15- 9.156kW SPR-327NE—WHT—D /SPR -+002+ UNIRAC RAIL 180 MODULE OTY. RIVERTER OTY. R... TLT AZIMUTR DC POWER RATNO (STC) 0-w z I I I I I I ATTACH MODULES TO PANEL RAILS STRUCTURE PER DETAILS EXISTING 2X6 r7 �wQN ANU UAIA SHLLI RAFTERS 3 ® 24" O.C. / PV LAYOUT PLAN 1 JUNCTION BOXES SCALE: 3/32" �owLLI v" ROOF SECTION PLAN N.T.S. MAIN SERVICE PANEL AC DISCONNECT PV SUBPANEL 3/4" E.M.T. ON ROOF/UNDER EAVE/ IN A I I IC AERIAL VIEW CLASS '1 - DIVISION 1 METALLIC CONDUIT W/NO JOINTS (N) AC UTILITY DISCONNECT (E) MAIN k(N) SUBPANEL SERVICE PANEL (N) INVERTERS 3'-0" PH 0 TO ARRAYS TV GAS GRADE MAIN SERVICE ELEVATION GENERAL NOTES: 1. CONDUIT RUNS ARE DIAGRAMMATIC,_ SUBJECT TO FIELD CONDITIONS AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET NEC REQUIREMENTS. 2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL BUILDING AND ELECTRICAL CODES. 3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITH STAND 110 MPH WIND -LOADS. REFER TO RACKING DATASHEET. 4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND UNDERSTANDING THE SECTION OF THE INVERTERS OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE SAFETY AND PROPER INSTALLATION. 5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. 6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE. 7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHT RESISTANT. 9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES PV SYSTEM SPECIFICATIONS TRASUNPOWER TILE CHM 901. 28 SB4oDOTL-US-22(2ao� 02ATTACHMENTS 15- 9.156kW SPR-327NE—WHT—D /SPR -+002+ UNIRAC RAIL 180 MODULE OTY. RIVERTER OTY. R... TLT AZIMUTR DC POWER RATNO (STC) 0-w z I I I I I I nom a r7 �wQN Q� un Pr) Z WZ�-r2 w Lj W �owLLI v" za(no j < — Li (O 0000I\ � zz <<n U H w z N J zlk o 0 cy) Cy W I- a' J 0 a_ w � � U I I I I I I nom a Q� un Pr) 0:E0< w=W�M za(no j < — Li (O 0000I\ � 0M N J zlk I 0-L) ^ J 0 w z c� N 9/23/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft M-1 2 PV ARRAY - GENERAL NOTES: INFORMATION VALUE DESCRIPTION GENERAL NOTES (7) PV ARRAYS 1. IF SERVICE PANELS DO NOT HAVE EXISTING too (3) STRINGS OF 08 GROUNDING ELECTRODE, IT n HE COi.E",TRAiu�s Module Wattage 327W Input data from PV Module data sheet (3) STRINGS OF 06 (1) STRING OF 07 GROUNDING ELECTRODE. 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE YA7H THE NEC AND ALL APPLICABLE REQUIREMENTS OF 2 ®6 BARE COPPER GROUND TO BE ATTACHED TO EACH Number of Modules 28 Total Modules for PV system THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. MODULE DIRECTLY VIA GROUND LUGS AND ATTACHED 2. ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE "--I MODULES To EACH RAIL WITH LUGS Module (VOC) 64.90V Input data from PV Module data sheet 3. EACH SOLAR MODULE SHALL BE GROUNDED USING THE 3. INTERMODULE MIRING-DURASHEATH LOW-VOLTAGE POWER. UNSHIELDED. EPR, HYP, VOLTS: 6GOVDC, U.L SUPPLED CONNECTION POINTS IDENTIFIED ON THE Module (VMP) 54.70V Input data from PV Module data sheet TYPE RHH/RHW-2/USE-2 CONDUCTOR SIZE (AWG/KEMIL) 10, RATED AT 90• WET OR DRY VATH MODULE PER THE MANUFACTURER'S INSTRUCTIONS MULTI-CONTACT LOCKABLE CONNECTORS Module (ISC) 6.46A Input data from PV Module data sheet Q)Z 4. ANY DC WIRING RUNS IN THE INTERIOR OF THE HOME SHALL BE RUN IN A METAL CONDUIT OR RACEWAY ® w Module (IMP) 5.98A Short circuit data from PV Module data sheet AND CLEARLY MARKED 'CAUTION DC-CIRCUIT' EVERY 5 FEET PER CODE REQUIREMENTS. (2) 86 EGO INVERTER (n)ACUTILITY MaxVOC of Inverter 600V Input data from Inverter data Sheet 5. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. ;! DISCONNECT � (E) SERVICE PANEL p ,�.. 5 6. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE PV Inverter PPTV Range 125 - 500V Peak Power Tracking Voltage from data sheet CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL (ROUNDING ELECTRODE r ( 77' Average high temperature 'F 7. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING.' Lr) IT IS THE CONTRACTORS RESPONSIBIUTY TO INSTALL A NEW SUPPLEMENTAL GROUNDING ELECTRODE. LLJ 29' Record low temperature F ® � I 8. USING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER (1) BB EGC B I , Modules per Branch 7 Module string configuration NEC „o.3(s) BOND TO CHASES (TYP.) (1) OCC I Number of Branches 2 , 2 Module string COnflgUratlOn S. TT:'RNINALStermNPROVIDE WARNING ce ON BOTH LINPER NEC E AND DIAD SIDNG ESMAY BE CEt�iERgZm OIN CKHAZARD-DO OSITNKNT TOUCH I Branch VOC 454.3V Module Voc x Number of Modules per Branch 10. LABEL 'PHOTOVOLTAIC UTILITY INTERACTIVE INVERTER' AND 'WARNING POTENTIAL ARC FLASH HAZARD CAN (N) ATTACH NEW DEC TO EXISTING BY IRREVERSIBLE MEANSye CAUSE: SHOCK, BURN, OR DEATH.- BOND I Branch VMP 382.9V Module Vmp x Number of Modules per Branch 11. LABEL 'PV SYSTEM U71UTY DISCONNECT SWATCH- SWITCH COVER TO BE LOCKED AT ALL TIMES SYATCH BOND TO CHASES (TIP.) Branch ISC 12.92A Module ISC x Number of Branches TO BE VISIBLE BLADE AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22 12. LABEL BREAKER "PHOTOVOLTAIC ELECTRIC POWER SOURCE' PER NEC 705.10 AND 'BREAKERS ARE BACKFED' VERALL SYSTEM AMPR 33.33A 8000/240V=33.33A PER NEC 690.64(B)(5) GROUNDING DETAIL PV SYSTEM VALUES 13. ALL MODULES WILL BE GROUNDED IN ACCORDANCE YAM CODE AND THE MANUFACTURER'S INSTALLATIONINSTRucnaNSNs. MODULES TO INVERTERS STRING 14. LABEL 'CAUTION' SOLAR CIRCUIT SHALL BE ON ALL EXPOSED CONDUIT, ENCLOSURES. CABLE ASSEMBLIES, WATTS) X (/ OF MODULES IN ARRA JUNCTION BOXES AND ALL AC CONDUIT ON MICRO-INVERTER SYSTEMS W = Y) (327 x 07) - 2289 WATTS msp rated 200A X 120% = 240A w < MAX PV SYSTEM VOLTAGE _ (VOC VOLTS) % (g OF MODULES) X CEC FACTOR (64.90 X 07) 454.3VOLT5 x 1.14 = 517.9V < BOOV INVERTER MAX VOLTS, compiles The Sum: 15. SEE DERATING PLACARD AND 'LOAD CALKS TO BE FIELD VERIFIED BY INSPECTOR AT FIRST INSPECTION' Z I''I 0 LO w N MAX CIRCUIT CURRENT = CEC FACTOR X (TOTAL SYSTEM WATT/ TOTAL SYSTEM VOLT) 1.25 X (2289/454.3)= 6.4 AMPS x 2 strings = 12.BA = LOAD TO INVERTER < 24A. ,stem complies mcb deroted to 175A + 45A = 220A 16. PV CONNECTION IN PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT ~ U < N INVERTER TO SERVICE PANEL SYSTEM System Compiles, the Sum did not exceed 120% FEEDER LOCATION OR MAIN CIRCUIT LOCATION. W w o va) LLJ MAX INVERTER AC POWER OUTPUT = (MAX AC POWER OUTPUT) WOO WATTS J as N w U MAX SERVICE VOLTAGE _ (110/24OV) 240 VOLTS 200A MAIN PV SYSTEM BOM Lj J MAX CIRCUIT CURRENT - CEC FACTOR X (MAX INVERTER AC POWER/240) 1.25 X (8000/240) - 41.67 AMPS7 Z < < ro 1.25 X (4000/240) - 20.83 AMPS WIRE CHART NEC 310.15(BO(3)(A) ACTUAL ITEM: DESCRIPTION: QTY. Z w o v l- � a6AWG 090C - 75A x temp deration of 80X for 4 conductors = 60A > SOA, system compllas 0 EL C � j8AWG 0900 - 55A x temp deratlon of BOX for 4 conductors - 44A > 41.67A. system complies O PHOTOVOLTAIC MODULES: SUNPOWER w O /10AWG 0900 - 40A x temp deration of BOX for 4 conductors - 32A > 20.83A, system complies MODEL: SPR-327NE-WHT-D 28 d PV SOURCE CIRCUITS O SURGE SUPPRESSOR - MNSPD-300, SEE INSTALLATION MANUAL ° ' (4) {EMD USE-2 PV WARE - POSITIVE _ PV 45A (4) g10 USE-2 PV WARE - NEGATIVEI'. 3 1 PV 125A SUB-PANEL 1 (4) g6 BARE CU (GND) CITY OF LA Q I NTA �� O JUNCTION 80X NEMA 3R 2 SR40MTIi 72 DING & SAFETY DEPT. WV_AliliNY_I_ /•1 1e m �...L ■ ' �1��� n INVERTERS: SMA AMERICA 5840007E-US-22 (240V) / SPR4002m -- 2- 1STRING of o7�D 01 02 03 04 OS 06 07 ' J Fi FalilKalilMMMMULMC__ R CONSTRUCTION ig7 READ ° AC UTIUTY DISCONNECT SWITCH (60A 24OVAC, NEMA-3R) 1 p PV ARRAY 2 r' t !" j O 6E 04 I 04 1 STRING OF 07 O Ol 02 03 OQ OS 06 07 . 'rEBY ✓/ B SYSTEM GROUND 1 0 D. I(7) < �1,.1Cl O BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY COMPANY 1 < D_' Q V) to I sy- 5 -1C) I o= PV SUB PANEL MAXIMUM NUMBER OF MODULE IN STRING: 07Uj ~ v I aA 12SA / 240V MAIN SERVICE PANEL OPERATING CURRENT: 11.96A z < vw) M o ' J-BOX 25 (E) 200A, J z w M� I �Y MCB DERATED TO 175A OPERATING VOLTAGE: 382.9V o o to M MAXIMUM SYSTEM VOLTAGE: 454.3V N J PV ARRAY 8 MAXIMUM OI TORT-OIRCUIT CURR[NT: 12,02A M a 1 STRING OF 07 �J Ol 02 03 Oa OS 06 07 VR4UOZM SLIT ACR I INVERTER 24OV Q M > w P_V_ARRA�4 1 STRING OF 07 U Ol 02 03 04 OS 06 07 A A e i 11/2/13 0 AC UTILITY (N)175A DRAWN BY: BPM DISCONNECT SWITCH ( I MCB APN: 609-580-002 60A, 240V, NEMA-3R " I 1 1 Typical awc wire stres 4A (� Wire 1/2" 3/4 1" IJ4" 1/2" 2" j c Im,] p;�.ar LOT: 0.27 acres -BOX 5 I I "" t_ ._ s \ Size EMT CMT EMT EMT EMT EMT I ,,, �,.� r_ ,;,,, ,,,. ,c.,, u:r*: '. LF4�.� = DWELLING: SFR, 2737sgft 45A 14 12 22 35 61 84 138 m 121 9 16 { 26 45 61 101 (4) /10 TNWN-2 -QM rJRQJ1T POSITIVE 10 1 5 10 I6 28 38 63 E- ■ (4) /10 7HWN-2 -NEGATIVE (2) 3/4' EMT CONDUIT O 8 1 3 6 9 16 12 36 t - - Cs ` -- 1-' -� ''� ) z a 1 (� , 1,• a ,u, 1,1,w,zTi1 yj 1 (4) H8 THWN-2 (GND) (8) pt0 THWN-2 1 7 I 6 z 4 7 12 16 26 II -j--1 SINGLE LINE WIRING DIAGRAM (4) 3/4' EMT CONDUIT 2 THWN-2 GID (1) #6 T EMT CONDUIT Y� () ( > 3 THWN-2 -��+ d 1 2 4 7 10 16 T- () r� i 3 1 3 4' EMT CONDUIT I ,-..� (1) 16 THWN-2 (OND) O / 1 3 { 1 1 { 3 6 8 13 '�, :�),,-(g>. et '.I 3 TIHWN-z J_ ,,,�,z1zx e• .. i.v ,zrlllr_ e:,.: . SCALE: N.T.S. () (1) H6 THWN-2 (GNO) z 21 1 1 1 _Lj_5 7 11 i- - SUNPOWEV E20/327 SOLAR PANEL S U N ®. E20/327 SOLAR PANEL V, MODEL: SPR-327N7WHT-D 20% EFFICIENCY ELECTRICAL DATA I-V CURVE C06 , ® SunPower E20 panels are the highest E MnYvda udnlLnCcJrrn.D:CLi,d'c:ud,�ryy/,•gn.N15,OnJY.t4runo+,°S C Peak Power( 7 10DOw10rastrc efficiency panels on the market today, +5/-3%) Pma, 327 w 6 ioww/mr more in the SERIES ciency n 22.5 % Cell Efficiency 5 providing power some amount of space Panel Efficiency n 20.1% Rated Voltage v,,,PP 54.7 V 5 4 -Nowt o Q 3 - -- Rated Current ImPP 5.98 A 2 "Ow".. MAXIMUM SYSTEM OUTPUT Open Circuit Voltage voc 64.9 V 1 Comprehensive inverter compatibility Short Circuit Current lu 6.46 A `v�"' 0 ensures that customers con pair the highest- Maximum System Voltage UL 600 v 0 10 20 30 40 50 60 70 efficiency panels with the highest -efficiency Temperature Coefficients Powe, (P) -0.38%/K Voltage M C..m...1-Imp cho.cOaw- -6 dcp-d— oa umdiance end m it 1. Imn/ef %- inverters, maximizing system output Vdrago N«)-176.6mV/K REDUCED INSTALLATION COST cur(cM (IK1 3.SmA/K TESTED OPERATING CONDITIONS = wQ NOCT 45• C +/- 2• C Y /) w Q N More power per panel means fewer panels Series Fuse Rating 20A Temperature - 40° F to +185° F 1- 40° C to + 85° C) Q z a CD to V) per install. This saves both time and money.113 Grounding Positive grounding not required pst 550 kg/ms 15400 Pal, from (e.g. snow) Max loud w w o m w w/specified mounting configurations Q w J U RELIABLE AND ROBUST DESIGN MECHANICAL DATA 50 psf 245 kg/m-' (2400 Pal front and back g Z W Q -i M a c�'- SunPower's unique Moxeon"cellSolar THE WORLD'S STANDARD FOR SOLAR"" Cells 96 SunPower Moxeon' cells (e.g. wind) LLI J o o w65 co ti in t` C7 technology and advanced module 9Y High.tronsmission tempered glass with Front Glass Impact Resistance Hail: (25 mm) of 51 mph (23 m/s) w to = to SunPower" E20 Solar Panels provide today's highest efficiency and anrireUective (AR) cooling Q P 'd -design ensure industry-leading reliability Junction Box IP -65 rated with 3 bypass diodes o performance. Powered by SunPower Maxeon"' cell technology, the E20 Dimensions: 32 x 155 x 128 mm WARRANTIES AND CERTIFICATIONS series provides pone[ conversion efficiencies of up to 20.1 %. The E20's Output Cables IODD mm cobtos / MuhiGontact (MCA) connectors Warranties 25yeor limited power worrony Frame Anodized aluminum alloy ype 6063 (block) l0yeor limited product warrant' low voltage temperature coefficient, anti -reflective glass and exceptional Weight 41.0 lbs (18.6 kg) Certifications Tested to UL 1703. Coss C Fire Rating low -light performance attributes provide outstanding energy delivery per I DIMENSIONS peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 041 '"' 7X°b.`6 i`61 'a''`ox�7iGn°tf5 -- _" -'. _- _ w o �tI - N ~ 20% s• �. 11 \1 It LU 1 191 JoVEnd I o= Q' I f(a� t n Q c/ 1, Of EyDI- o p Q Z W to to p 10%_-. _ _ - t -jaae0t, �o�rn I C14 -i eM° + d U I L - , E � E ES ID _ -- _ �, y.'• O THIN fl(Ni CONVENTIONAL -_ _ Z MAXEON"' CELL SERIES SERIES SERIES N Please read safety and installation instructions before using this product, visit sunpowercorp.com 9/23/15 TECHNOLOGY for more details. Patented otboc2rontoci so'or cell, sun owercor cam P P• C2011 &.P.— w„ro,.�,ti.,,,,.,, sun owercor .cam o.e ��,. �.v,an+<uvc�ossw4xrDroesoupadf.,array+o..,a..�, P P dS, P «c�Y<.ae,.usmdd' M-'11m.AAJW� P-W"a.sl`".—;«s Lliti;'&, I,---14W.,,r—..+.A , a�d.xt.510.e� s!c er DRAWN BY: BPM pravHcie the industry's higreliability nr„ e.;icienq and reltabtliy C E US O APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgft D-1 MODULE DATA SHEET 1 SCALE: N.T.S. 4 Certified • Ul 1741 and 16998 compliant • Integrated AFCI meets the requiro- ments of NEC 2011 690.11 M ENGINEERED a IN GERMMY ASSEMBtED92 IN THE USA= Innovative • Secure Power Supply provides daytime power in ooze of grid outage :SMA Powerful Flexible • 97.2% maximum efficiency • Two NPP trackers provide • Wide input voltage range numerous design opeom • Shade management with OptfTrac • Extmrded operating Global Peak MPP tracking tompetcrure range Intertek SUNNY BOY 3000TL-US / 3800TL-US /4000TL-US / 5000TL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL•US/3800TL•US/4000TL-US/5000TL-US represents the *next step in performance for UL certified inverters. Its transformerless design means high efficiency and reduced weight. Maximum power producfion is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OpliTrocs" Global Peak mitigate the effect of shade and allow for installation of challenging sites. The unique Secure Power Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative features make the Sunny Boy Tt-US series the first choice among solor professionals. INVERTER DATA SHEET 1 SCALE: N.T.S. ERiaan<y a:rvo suNNY iter SDoonuS 1 -- - w r / of Ira 5zz- A.AVob-w RS4B5 erpfac� imerlors � Dt+u85CBUS10 rwtws 10 Fon sen iMK1107•IO Sunny Boy SOOOTL•US eb L 208 V AC 2410 V AC 04 208 V AC 240 V AC F777 v -M i in 1 -- - w r / of Ira 5zz- A.AVob-w RS4B5 erpfac� imerlors � Dt+u85CBUS10 rwtws 10 Fon sen iMK1107•IO Sunny Boy SOOOTL•US eb L 208 V AC 2410 V AC 04 208 V AC 240 V AC F777 % i in 3200 W 4200 W 4200 W x 90f (n W i as 600 V -• Em 1V„ - 175 N � w < 175 - 480 V - imN,-40oN g6 I -•• Frof+.`48o1 125 V - 500 V 125 V - 500 V 125 V - 500 V 0.0 0.2 0,4 06 Output power / Rated Technical data Input (DC) Max. DC. power (® cos 9 - 1) Max. DC voltage Rated MFPT voltage range MPPT operating voltage range Min. DC voltage / start voltage Max. input current / per MPP Crocker Number of MPP trackers / strings per MPP tracker Output (AC) AC nominal power Me& AC apparent power Nominal AC voltage / adjustable AC voltage range AC grid frequency, range Max. output current Power factor (cat 91 Output phases / Fine connections Hormonics Efficiency Max. efficiency CEC cffciency Protection devices DC disconnection device OC rovenopolotity protection Ground Fault monitoring / Grid monitoring AC short circuit protection A5pole sensitive residual current monitoring unit Arc fault circuit interrupter (AFCQ compliant to UL 16998 Protection class / overvoltogo category General data Dimensions (W / H / D) in mm (in) OC Disconnect dimensions (W / H / D) in mm (in) Packing dimensions (W / H / D) in mm. (in) DC Disconnect packing dimensions (W / H / D) in mm (in) Weight/ DC Disconnect weight Packing weight / DC Disconnect packing weight Operating temperature range Naso emission (typical) Internal consumption at right Topology Cooling concept Electronics protection rating Features Secure Power Supply Display: graphic Interfaces: RSASS / Speedwire/Webconnect Interface: Z;SBee Warranty: 10 / 15 / 20 years Certificates and pee its (more available an request) NOTE US inveners ship with Stay lids Type designation Toll Free +1 888 4 SMA USA www.SMA-America.com Accessories 0.8 1Dl I• Standard feature O Optional feature - Na available .-..---.-.-.....-•.-•- Data at nominal condi4k= Sunny Boy 3000TL-US 5zz- A.AVob-w RS4B5 erpfac� imerlors � Dt+u85CBUS10 rwtws 10 Fon sen iMK1107•IO Sunny Boy SOOOTL•US ��/ 0.8 1Dl I• Standard feature O Optional feature - Na available .-..---.-.-.....-•.-•- Data at nominal condi4k= Sunny Boy 3000TL-US Sunny Boy 3800TL US Sunny Boy 40OOT4U5 Sunny Boy SOOOTL•US L 208 V AC 2410 V AC 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC LU 3200 W 4200 W 4200 W 5300 W (n 600 V 600 V 600 V 600 V w < 175 - 480 V 175 - 480V 175 - 480V 175 - 480V LLI Q CV 125 V - 500 V 125 V - 500 V 125 V - 500 V 125V -. 500V w Z 13- Cn M 125V/ISO V I25V/ISOV 125V/150V 125V/150V p0Ls1 18A/15A 24A/15A 24A/ ISA 30A/ ISA (nWULLJ 2/2 -J� ~Z�<QM Z F -o 3000 W 3330 W 3840 W 4000 W 4550 W 5000 W < W co o Z 3000 VA 3330 VA 3840 VA 4000 VA 4550 VA 5000 VA p p cn0 208 V / • 240V/ • 208V/ • 240V/ • 208 V/ • 240V/ • 208 V/ • 240V/ • 5 = _ M < 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 v 183 - 229 V 211 - 264 V V F- d 60 Hz/59.3-60.5 Hz 60 Hz/59.3-60.5 Hz 60 Hz/59.3-60.5 Hz. 60 Hz/59.3-60.5 Hz `a U 15A 16A 20A 22A '� I I 1 1 T% s. 1/2 1/2 1/2 1/2 'sp c4% <4% <4% <A% 96.8% 97.1% 96.8% 97.2% 96.6% 97.29 96.8% 97.1% 96% 96.5% 961A 96.5% 969 96.5% 96: 96.5% -; a x= I • a.4 I • �' O • p04m < Of LJ 0 • Ex -'0C)< I 1/N ?^ ON= J� V) 1-:C) 490 / 519 / 185 (19.3 / 20. / 7.3)z € LLJ M 187/297/190(7.4/11.7/7.5) f=• Z<NtO <ZWMto 617 / 597 / 266 (24.3 / 23.5 / 10.51 = d p p M 370/240/280 (14.6/9.4/ 11.0) 0 M 0) 24 Lg 153 Ib) / 3.5 Lg 18 lb) M < U 27 Lg (60 lb) / 35 kg 18 lb) ' "- I . to -40•C -+60•C (-40•F-.+140•F) l,• J I' 5 25 48(Al < 25 dBIA) < 25 dSlA) < 29 dB(A) p < I W <1W _cI <1W Z Tronsformedess Tronsfomteriess Tromformerless Tronslormerkss O Convection Convection Convection Convection Cn 9/23/15 NEMA 3R NEMA 33 NEMA 3a NEMA 3R z • • • • " x DRAWN BY: BPM • • • • as APN: 609-580-002 0/0 0/0 0/0 0/0 c = •/o/0 •/o/O 0/0/0 •/o/oLOT: 1 t 0.27 acres DWELLING: SFR, 2737sgft UL 1741, UL 1998. Ut 16998, IE--cE1547, FCC Pon 15 (CkmsA & Bl. CAN/CSA 022.2 107.1.1 D-2 SB 3000TWS•22 SB 3BOOTL-US-22 58 4000n -US -22 SB 5000T1•US22 w SMA America, LLC E tot) lin �f rrd 1%,wrPrn TileTrac Ptrtcm �i,1�b,424 � » , 1 Tile Roof Structural Attachment NEWT STAINLESS STEEL TILE FLASHING The patented TileTrom anachment allows for a stroctuml roof rafter connection with optimal attachment stud locution adjustability. Design results in the best looking systems in eke industry. Tile Truc�'fors-curve 7'ileiyac"f�; flat. concrete t7le concrete Mile ' (G" Tall Tbrraded 5twrd) ,t W' TALL 71srPaded.Vrzfdj Be;w is of McTvac • Easiest and lowest cost waterproof tie roof • Includes Stainless Stool file flashing and attachment Stainlass Staal log bolt • Over 15 years of industry proforred single log • Aluminum and Stainless Steel components for bolt design maximum corrosion resistance and strength. • 37d party, lob waterproof and load tested • Largo roof surface contact area ovenly • Compression sealed at undorlayment and top disirbutas load of the The TileT-ac• Desip. Structurally attaches to roof rafter and allows the rail. attachment stud to be located at the strongest point of the file. (the crown) where water does not flow. Without TileTrac' DICALE-�"M TTAENT DATA SHEET N.T.S. qh Valley h teae Cr With TileTTrac"' water Flaws "' Crown n Seated at fop of t7e— in Y of the Tile at the We (optimum? tt,�•+`assemblyy Seated at � sfiuctuM undetfaymeot Rafter attached to the rafter Installation steps for both s -curve and flat concrete We* ��nfJ lilsS¢cic' ►fr � f,�(tfi Tr STEP I: Select a tile in the area of the roof rafter Step 4: Seal the initial file nail hole. Using a 3/16" drill bit and drill guide (Fl -Grill), drill pilot hole along the rafter center STEP 2. Remove the file by pushing and pulling It is usually held in place by o small nail. Step S: Insert the lag bolt and washer through the TiteTracco and apply fresh compatible sealant to the base. Step 1: After Wfing the base to the rod, slide the upper carriage into the correct position under the crown of the tie. For flat file, side the upper corriage near the middle of the tile. y Tip: iMd,(,2) 3�8" nuts to top e of stud p to roof'work Step 8: Replace the file by lining up the snap lines and mark the drill location accordingly. STEP 3. Using an electronic stud finder (recommended), or other means, locate the rafter center. Mark a reference point on the file above. Tip�'""`� Use a cordless i. act wrench Step 6: Using a 1/2" socket, install the lag bolt unfit seated. Do not overtighten. The sealant should How outward seding any holes. Step 9: Using a 1/2" carbide drill bit and ROTARY HAMMER DRILL in hammer mode, drill through the tile. See online video at www.prosolar.com for details. Step 10: Insert threaded stud through tile and handaighten Step 11: Unbind nuts and remove from stud. Apply to engage with base. Bind two 3/8" nuts (included) using sealant around stud of file opening and compress 9/16" wrenches and lighten. with Stainless Steel flashing (included) unfit seated. Step 12. Fasten roil with lower and upper 3/8" nuts/washers as shown. 'Not recommended for clay or slate tiles. @Professional Solar Products, Inc. Mar. 2011. -CileTracais a registered trademark and covered under Pat. #5,746,029 � W Vat sSuciumlty Rafter cauehed to the mitt DICALE-�"M TTAENT DATA SHEET N.T.S. qh Valley h teae Cr With TileTTrac"' water Flaws "' Crown n Seated at fop of t7e— in Y of the Tile at the We (optimum? tt,�•+`assemblyy Seated at � sfiuctuM undetfaymeot Rafter attached to the rafter Installation steps for both s -curve and flat concrete We* ��nfJ lilsS¢cic' ►fr � f,�(tfi Tr STEP I: Select a tile in the area of the roof rafter Step 4: Seal the initial file nail hole. Using a 3/16" drill bit and drill guide (Fl -Grill), drill pilot hole along the rafter center STEP 2. Remove the file by pushing and pulling It is usually held in place by o small nail. Step S: Insert the lag bolt and washer through the TiteTracco and apply fresh compatible sealant to the base. Step 1: After Wfing the base to the rod, slide the upper carriage into the correct position under the crown of the tie. For flat file, side the upper corriage near the middle of the tile. y Tip: iMd,(,2) 3�8" nuts to top e of stud p to roof'work Step 8: Replace the file by lining up the snap lines and mark the drill location accordingly. STEP 3. Using an electronic stud finder (recommended), or other means, locate the rafter center. Mark a reference point on the file above. Tip�'""`� Use a cordless i. act wrench Step 6: Using a 1/2" socket, install the lag bolt unfit seated. Do not overtighten. The sealant should How outward seding any holes. Step 9: Using a 1/2" carbide drill bit and ROTARY HAMMER DRILL in hammer mode, drill through the tile. See online video at www.prosolar.com for details. Step 10: Insert threaded stud through tile and handaighten Step 11: Unbind nuts and remove from stud. Apply to engage with base. Bind two 3/8" nuts (included) using sealant around stud of file opening and compress 9/16" wrenches and lighten. with Stainless Steel flashing (included) unfit seated. Step 12. Fasten roil with lower and upper 3/8" nuts/washers as shown. 'Not recommended for clay or slate tiles. @Professional Solar Products, Inc. Mar. 2011. -CileTracais a registered trademark and covered under Pat. #5,746,029 W = W a''� � W Q N M W W N W J U Z W Q Q M LLJ W D U Z O 000 W a -� Z P-4 I i i �rn Q m Q(rQNM I O x ,UQ� c`'—o zakt QZiWMcD _j Do r- -o:2rn 0:2 0) ^a�t I 0 W Z 1 SolarMount Beam Connection Hardware SolarMount L. -Foot Part No. 304000C, 3040000 Y ►X is s,sorr�• `i iutbx'ti0i ` - Lot Dimensions specified in inches unless noted RAIL DATA SHEET SCALE: onswUNIRAC • L -Foot material: One of the following extruded aluminum alloys: 6005- 75, 6105-T5. 6061-•6 • Ultimate tensile: 38ksi. Yield: 35 ksi • Finish: Clear or Dark Anodized • L -Foot weight: varies based on height: -0.215 lbs (98g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized 30/t UNIRAC documents L -Foot For the beam to L -Foot connection: • Assemble with one ASTM F593 %*-16 hex head suew and one ASTM F594 %"serrated flange nut • Use anti -seize and tighten to 30 ft4bs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory NOTE: Loads are given for the L -Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, 4) Sliding, Zt 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension. Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression. Y- 3258 (14492) 1325(5893)1 2.461 2004 (8913)1 0.615 Traverse. Xt 486 (2162-) 213 (949) 2.28 323 (1436) 0.664 N.T.S. SolarMount Beams Part No. 310132C, 3101321-8, 3101681, 310168C-8, 3901681) 310208C, 310208C-8, 310240C, 310240C43. 3102400, 4101404,4101168M, 410204M. 410240M Properties Units SolarMount Solarmount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area in' 0.676 1.059 Section Modulus (X -Axis) in' 0.353 0.898 Section Modulus (Y -Axis) W. 0.113 0.221 Moment of Inertia (X -Axis) in' 0.464 1.450 Moment of Inertia (Y -Axis) in' 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 rRadius of Gyration (Y -Axis) in 0.254 0.502 71 SLOT FOR T -BOLT OR I/4" HEX HEAD SCREW 2X SLOT FOR BOTTOM CLIP 2.500 T SLOT FOR O HEX BOLT 387 750 Y W X SolarMount Beam Dimensions specified in inches unless noted 7 IR LLJ Ln Q 0 J 10 LLJ QN U N WZ � M w o o LLI W J U Z Q Q M LU U Z o oL,u)Dr- LLJ 2 co d a vQ J w o >.—U �p ~ N o) m Q w Q Lf) ODUQ� (n (n J h U � i zQv�w)'�p < LLJ aoo�� N m I-)00 (L (mo) I J I 0 U.1 Z 9 DRAWN BY: BPM APN: 609-580-002 LOT: 0.27 acres DWELLING: SFR, 2737sgfi D-4 7 JUNCTION BOX & CONDUIT RACEWAYS NEC 690.31(E)(3) — CONDUIT / ALL JUNCTION BOXES WARNING: PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) — UNDERGROUND SYSTEM JUNCTION BOXES WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE INERGIZED. DC DISCONNECTS NEC 690.14(4) GROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD DO NOT TOCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.35(F) UNGROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED. NEC 690.14(C)(2) PHOTOVOLTAIC DC DISCONNECT NEC 690.53 WARNING PLACARDS 1 SCALE: N.T.S. TNVFRTFR NEC 690.5(C) — GROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUND AND ENERGIZED NEC 690.35(F) — UNGROUNDED SYSTEMS WARNING: ELECTRIC SHOCK HAZARD DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNDERGROUND AND MAY BE ENERGIZED DC DISCONNECTS PRODUCTION METER AG DISCONNECTS ONLY AT METER LOCATION NEC 690.14(C)(2) PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM METER AC DISCONNECT NEC 690.54 NEC 705.12(D)(4) — ON A LINE SIDE TAP WARNING: DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM MAIN SERVICE PANEL NEC 705.12(D)(7) — NEAR PV BREAKER WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE NEC 705.12(D)(4), 690.56(B) — ON PANEL COVER CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY JUNCTION BOX & CONDu1rT aermwwvc WARNING: DUAL POWER SOURCE POWER IS BEING SUPPLIED TO THIS PANEL FROM THE UTILITY AND A SOLAR PV SYSTEM. THE SOLAR PV DISCONNECT IS LOCATED: NEC 690.14(C)(2) — NEAR PV BREAKER PHOTOVOLTAIC AC DISCONNECT NEC 690.54 — ON PANEL COVER b:❑ T1 �Q O IA 4-+ ,n W Z a M C � U Q N OpwQ`h ,r1 ,k3wuj0�r VZ-QQr) Z w p U Z 0 z0 Q J I I I I I � N lil Cpm a; a Jp�ca)Q" I QVWi�Mp I zLLJ QZ W hIp a00 big 0 m 0) ro¢ah J I Ct 41 21 9/23/15 DRAWN BY: BPM APN: 609-580-002 LOT: 0.2:7 acres DWELLING: SFR, 2737sgil 9 X13-05 CA��t 6C 20 �- D OPTIONAL CALCULATION SINGLE-E6MILYDWELLING (NEW OR EXISTING) 1. OTHER LOADS: 220.14 General lighting loads: 220,12 :2-73.7 sq. ft. x3VA= Small appliance and laundry loads: 220.52 1500 VA x �'� circuits = Special loads: Dishwasher = Disposal = Compactor = Water heater = Pte\ go t^f, 3 `^ P ti Applying demand factors: 220.82 First 10,000 VA x 100% = Remaining j ,Eb VA x 401%= 2. HEATING OR A/C LOAD: 220.82 Heating units (3 or mss) .. .9- _VA x 65% = Heating units (4 or more) = VA x 40% A/C unit 7g7(. =VA x 100% = Heat Pump =VA x 100% = SERVICE: 1 =VA V SERVICE: 1 = -Y& = A 240 10 ?:2)) - VA CITY OF LA QUINTA , 2s VA BUILDING & SAFETY DEPT, SOC> VA APPROVE® 1$*C> VA FOR CONSTRUCTION VA VA DATE—/ % / BY 7_•__�_VA YI/76 VA VA VA (Total) y8 So 1 VA 10.000 VA i Sq 0 VA (Total) Y00 VA oi�- VA. VA "7 ? 7 6 VA VA TOTAL = �Q7�VA For a one -family dwelling, the service disconnecting means shall have a rating of not less than 200 amperes, 3 -wire, with a minimum 225 amp ss. _ Service amperes required .gyp Service amperes provided (� ARC -Fault cincrit4nterruptlon protectton required per 210.12 Description: MOFIDI / 9.15kW PV SYSTEM - (28) 327W PANELS/(2) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 10/8/2015 SGU Approved: 11/9/2015 LUR Parcel No: 609580002 Site Address: 43695 CALLE ESPADA LA QUINTA,CA 92253 Subdivision: TR 29323-1 Block: Lot: 80 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $28,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 CHRONOLOGY TYPE Details: 9.15kW SOLAR ARRAY - (28) 327W SUNPOWER MODULES (2) SMA AMERICA BA4000TL-US-22 INVERTER, MAIN BREAKER DERATED . TO 175AMP, & 125AMP LOAD CENTER. [463SF] 2013 CALIFORNIA ELECTRICAL CODE. Printed: Monday, November 09, 2015 4:09:06 PM 1 of 3. CPEAJF SYSTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME . ACTION DATE COMPLETION DATE NOTES PLAN CHECK SUBMITTAL STEPHANIE GUMPERT 10/8/2015 10/8/2015 RECEIVED TELEPHONE CALL LUIS URIBE 10/15/2015 10/15/2015 CONTACTED PLANET SOLAR. 1ST REVIEW IS COMPLETE PLANS ARE READY FOR CORRECTIONS. TELEPHONE CALL LUIS URIBE 11/9/2015 11/9/2015 SPOKE WITH BARBERA AT PLANET SOLAR. PERMIT IS READY TO BE ISSUED. CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT PLANET SOLAR INCORPORATED 719 E HALEY STREET SANTA CA 93103 BARBARA Printed: Monday, November 09, 2015 4:09:06 PM 1 of 3. CPEAJF SYSTEMS FINANCIAL 1 .1• DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD .,'PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA: PV SYSTEM -ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC PV SYSTEM - MISC 101-0000-42403 0 $24.17 $0.00 EQUIPMENT PV SYSTEM - MISC 101-0000-42600 0 $24.17 $0.00 EQUIPMENT PC Total Paid for ELECTRICAL: $96.68 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:•0 00 Printed: Monday, November 09, 2015 4:09:06 PM 2 of 3 =SYSTCMS Permit Details PERMIT NUMBER ` City of La Quinta BSOL2,015=0202 IST BLDG NS (1 WK) LUIS URIBE 10/8/2015 10/15/2015 10/15/2015 REVISIONS REQUIRED 2ND BLDG NS (1 . WK) LUIS URIBE 11/2/2015 11/9/2015 11/9/2015 APPROVED Printed: Monday, November 09, 2015 4:09:06 PM 3 of 3 c SYSTPAAS Iain # city of La Q um to Building 8i Safety Division (7�� 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �\ Project Address: 3 6A Alk, Owner's Name: DEQ M dFIOS A. P. Number: Address: I-•\ '� Q C: )� AVOA Legal Description: City, ST, Zip: Contractor: c r: �Y� o ba P hone: Telephone: Address: 3 ZO t �`' s' �p�•G l%�, Project Description: City, ST, Zip: e(Mi� oast] oe 2 2 I 1 elehon•6 O T e. e7 2 1 State Lic. S 3 3 City Lic. #; Arch., Engr., Designer: Address: City, ST, Zip: .................................................... Con truTelephone: Occupancy:c .ctionTYPe: State Lic. #. Project type (circle1 one): New Ad d'n Alter Repair Demoo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: (� Estimated Value of Project: a 6-ary APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance .Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue 'Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- ''d Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.I'. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees