Loading...
BWFE2016-0028.. I Illill •11111 IIII VOICE (760) 777-7125 27 78-495 CALLE TAMPICO � FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Dater 2/9/2016 Application Number: BWFE2016-0028 Owner: Property Address: 53840 AVENIDA HERRERA DONALD DODSON APN: 774164006 Application Description: LINDA DODSON / BLOCK WALL 922 nA Property Zoning: Application Valuation: $3,000.00 FEB 09 2016 Applicant: Contr ct : VELASQUE2 MASONRY VELA QUEZ hQUINTA OUTSIDE CITY LIMITS 3026 WEMDEPARNENT CATHEDRAL CITY, CA LICENSED CONTRACTOR'S DECLARATION - I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class- C29 License No.: 301880 Date: 21 Contractor: 0— a, -A— - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business.and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under.Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (760)321-2193 LIc. No.: 301880. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thewo k for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sectio 3700 of the Labor Code, for the performance of the work for which this permit. is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California; and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply withthose provisions. Date: Z 11(o Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,.the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentionneproperty for inspection purposes. Date: a 1 1� Signature (Applicant or Agent): V FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT . PAID :' PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 2/9/16 PAID BY METHOD RECEIPT # .., ; CHECK # CLTD BY VELASQUEZ MASONRY CHECK R12723 3418 RSE Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPTION .. ACCOUNT qTY AMOUNT . PAID: ' PAID DATE WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 $47.86 2/9/16 PAID BY METHOD '. RECEIPT # CHECK # CLTD BY VELASQUEZ MASONRY CHECK R12723 3418 RSE DESCRIPTION : ACCOUNT . >'. QTY AMOUNT.: PAID PAID DATE WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 $60.91 2/9/16 PAID BY `METHOD RECEIPT # CHECK #. CCTD:BY VELASQUEZ MASONRY CHECK R12723 3418 RSE Total Paid for FENCE OR FREESTANDING WALL: TOTALS:0• $108.77 $108.77 0• Description: LINDA DODSON / BLOCK WALL Type: WALL/FENCE Subtype: CITY STANDARD/PRE- Status: UNDER REVIEW Applied: 2/9/2016 RSE APPROVED Approved: Parcel No: 774164606 Site Address: 53840 AVENIDA HERRERA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA.VALE LA QUINTA Block: 238 Lot: 19 Issued: UNIT 22 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 STATE Details: PROTO 2 / 70LF OF 6' GARDEN SOUTH SIDE YARD PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL SITES CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY . STATE 'ZIP PHONE FAX EMAIL APPLICANT VELASQUEZ MASONRY OUTSIDE CITY LIMITS CONTRACTOR VELASQUEZ MASONRY 30266 MUIRFIELD WAY CATHEDRAL CITY CA 92234 OWNER DONALD DODSON 92253 FINANCIAL INFORMATION Printed: Tuesday, February 09, 2016 11:55:05 AM 1 of 2 CB? SYSTEiNS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 2/9/16 R12723 3418 CHECK VELASQUEZ RSE MASONRY Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: WALL/FENCE - FIRST 101-0000-42404 0 $47.86 $47.86 2/9/16 R12723 3418 CHECK VELASQUEZ RSE 100 LF MASONRY WALL/FENCE - FIRST 101-0000-42600 0 $60.91. $60.91 2/9/16 R12723 3418 CHECK VELASQUEZ RSE 100 LF PC MASONRY Total Paid for FENCE OR FREESTANDING WALL: $108.77 $108.77 TOTALS:0• i• .77 ATTACHMENTS Printed: Tuesday, February 09, 2016 11:55:05 AM 2 of 2 SYSTEMS Bin'# City of. La Quinta Building 8T Safety Division 78-495 Calle Tampico coZl:z La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking.Sheet Permit # 16 Project Address:C �d til/%, � Owner's Name: A/ A. P. Number: Address: !9 IYW Legal Description: City, ST, Zip: 14 62(, i A /— 4OJ2 2 Contractor: '^ _ U �-t� S� Telephone: p o e. Address: W2(O I Lq. Project Description: City, ST, Zip: Telephone7601 SO)/ : 6LO c V State Lic. # : 301 ag?) City Lie. #..()l 0$-()2-161 Arch., Engr., Designer: N (.HCl.Llr> -6 Address: City, ST, Zip: Telephone: P ele h ne: Construction T e: Occupancy: YP a State Lac. # S air Project ect tyPe circle one • New Add'n Alter Repair Demo Nametof Contact Person: J(�� L�_ Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: — "$ Estimated Value of Project: boo — APPLICANT: DO NOT WRITE BELOW THIS LINE H Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- 'rd Review, ready for correctionsCssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees f" (&4r TOW -0 PROTO 11 - EXPOSURE C - DIP FOOTING HORIZONTAL JOINT 4 " L) 12" TO 36" _ DESIGN CRITERIA (PER 2013 CBC): C f n 1. ALLOWABLE SOIL BEARING PRESSURE PROTO II FENCE WALL TY OF LA ' V ��IA'�A COURSES BELOW.PLATE / = 1000 PSF MIN. SOIL PASSIVE PRESSURE UILDI DPT. 2. ALLOWABLE JOB NUMBER ^ A REINFORCING AT 6'-8" uj = 150 PCF MIN. TENSION (PT) FENCE. USE 1 #4 IN v PR 8�19�1� — 3. SEE SHEET B. C, & D PRIOR TO 6" STD. HOOK TNG g DRAVIN S40 5 m ION START OF CONSTRUCTION. 1N WALL Ilk x CARUSO 6" CAP BLOCK PER �� 'm' ��a== II DATE ENGR JAC — TURLEY SHEET C ��m�-� WWW.PROT02.COM 41800 CASCADES COURT TEMECULA. CA 92591 08.19.2014 S� \ 9 STEEL PLATE TO BEAR II omm ATTN: GARY OTTO PI)/ (951) 694-3793 PACKAGE SHEET 17 FULLY ON CENTER WEB ` a a - gwyotto@protoiLcom (MAY My ff MTALUM RT AQMOV A AW OMMM DWALUMS) - OR END FACE SHELL - av »> N� »> s. 6'. am fr D= rosy-T[Wm MA WY+nuts •(� — THESE DRATONGS/CALaUTIONS ARE (,OW ED PIT£ —IMIURY -NOT FOR MTRUCTtON OR RECORDA(G LUZ% THE STRUCTURAL EMMIR OF REOWS RX IS AFFIXED EM IWITTEN SIMATURE, SIZE PER SHEET C. POST TENSION (PT) NO COLD JOINTS SEE SHEET B — PERMITTED BETWEEN DIP zROD AND SETTING PAD — _t N J O W Ty J tw00 Z, N CL = EL p�Qa U7ir-o J Q W N C3 ,r-PROTO II FENCE WALL PER CHED FINISHED GRADE 4 CONTINUOUS AT HOOK z 2 1 MAX I I CONT. CONCRETE I I SETTING PAD — FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURS, INSTALL DRAINAGE BLOCK AT SWALE AT GRADE. CONCRETE DIP FOOTING DIP MAY BE OVER EXCAVATED AS SHOWN— FILL WITH COMPACTED FILL OR CONCRETE DIP DEPTH AT TOP OF 2:1 SLOPE SETBACK - FACE OF FOOTING TO TOP OF SLOPE HORIZONTAL JOINT 4 " L) 12" TO 36" 2'-4' 6" TO 11" REINFORCING TOP 2 W 3'-1" COURSES BELOW.PLATE / N AND AT 24" O.C. BELOW VERTICAL FOOTING—/ t(4 Ll JOB NUMBER REINFORCING AT 6'-8" uj !JA i c� 13&sco114-115-9155 TENSION (PT) FENCE. USE 1 #4 IN v PR G)seA1 8�19�1� OD SEE SHEET B FOR CENTER OF DIP 16" MIN TNG g DRAVIN S40 5 m ROD SPECS - CENTER 1N WALL Ilk x CARUSO �� 'm' ��a== O W Ty J tw00 Z, N CL = EL p�Qa U7ir-o J Q W N C3 ,r-PROTO II FENCE WALL PER CHED FINISHED GRADE 4 CONTINUOUS AT HOOK z 2 1 MAX I I CONT. CONCRETE I I SETTING PAD — FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURS, INSTALL DRAINAGE BLOCK AT SWALE AT GRADE. CONCRETE DIP FOOTING DIP MAY BE OVER EXCAVATED AS SHOWN— FILL WITH COMPACTED FILL OR CONCRETE DIP DEPTH AT TOP OF 2:1 SLOPE SETBACK - FACE OF FOOTING TO TOP OF SLOPE MIN. DEPTH D DIP FOOTING 12" TO 36" 2'-4' 6" TO 11" 2'-11" 3" TO 5" 3'-1" I f SEE SHEET D FENCE WALL SCHEDULE AT LEVEL SOIL I I H' DESIGN WIND PT ROD DIP I I MAX EXP/MPH SPACING SPACING I I C AT 100 6•-0" '-0p 70 6.-0D CQ AT,F4ap-- " s (-I-- 'A '1 r�. a AY - 7 -��8TAYUGHT Cpa TCON��• CjAT UNE OF DJP6�-8" C,AT 110 `�� � � �� LA FOOTING BEYOND.. . II STANDARD ITA. CA F ss CAT 12 U Q N p,T I t(4 Ll JOB NUMBER Eo oN !JA i c� 13&sco114-115-9155 G)seA1 8�19�1� TNG g DRAVIN S40 5 m 14-115-8964 TMH ELI Or CARUSO �� 'm' ��a== PROT04I Tm wALL SYSTEMS DATE ENGR JAC w sTRUCTU�P� TURLEY ��m�-� WWW.PROT02.COM 41800 CASCADES COURT TEMECULA. CA 92591 08.19.2014 S� \ 9 SCOTT INC- .•� omm ATTN: GARY OTTO PI)/ (951) 694-3793 PACKAGE SHEET 17 OF CAL ` a a - gwyotto@protoiLcom (MAY My ff MTALUM RT AQMOV A AW OMMM DWALUMS) J S1 www.ctsoz.com av »> N� »> s. 6'. am fr D= rosy-T[Wm MA WY+nuts •(� — THESE DRATONGS/CALaUTIONS ARE (,OW ED PIT£ —IMIURY -NOT FOR MTRUCTtON OR RECORDA(G LUZ% THE STRUCTURAL EMMIR OF REOWS RX IS AFFIXED EM IWITTEN SIMATURE, GENERAL STRUCTURAL NOTES 1. SOIL SHALL BE FIRM AND COMPACTED PRIOR TO PLACEMENT OF CONCRETE. PRIOR TO. FOUNDATION EXCAVATION, USER SHALL VERIFY THAT SITE SOILS CONDITIONS MEET OR EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 150 PSF/FT (SOIL CLASS 4 OR BETTER AS DEFINED BY THE CBC) STARTING AT THE TOP OF GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR PASSIVE) AND A MINIMUM ALLOWABLE BEARING PRESSURE OF 1000 PSF. 2. FOOTINGS TO BE LEVEL. IF GROUND SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP SHOULD BE PROPER HEIGHT TO FIT BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND CONTAIN NO LOOSE EARTH OR FOREIGN MATTER. 3. SEE SHEET A FOR EXPOSURE, WIND SPEED, POST TENSIONED ROD SPACING, FOOTING SIZES, ETC. USER IS RESPONSIBLE TO VERIFY REQUIREMENTS WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE APPROVED SITE PLAN AND APPLICABLE CODE OR JURISDICTION REQUIREMENTS. 4. SOIL BELOW FOUNDATIONS SHALL BE WELL DRAINED AND NON -EXPANSIVE. USE CONCRETE WITH A MIN. STRENGTH OF 2.500 PSI - TYPE 11 CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN. OF 48 HOURS OLD PRIOR TO FINAL TENSIONING ALL ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS DURING PLACEMENT. 5. LAP REINFORCING STEEL: LAP = 32" FOR g4 BARS IN CONCRETE. 6. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F°M DESIGN CRITERIA FOR BLOCK IS BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR TO ROD TENSIONING. STANDARD HEAD AND BED JOINT BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED. BLOCKS SHALL BE LAID IN RUNNING BOND. 7. MORTAR SHALL BE TYPE S. 2000 PSI MIN. MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL TENSIONING AND 24 HOURS OLD PRIOR TO FINAL TENSIONING. 8. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING. 9. REINFORCING REBAR SHALL CONFORM TO ASTM A641; Fy = 60,000 PSI. 10. PROTO-11 HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL THREADS, DIRECT TENSION INDICATORS (A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE SHALL BE SUPPLIED BY ONLY AN APPROVED PROTO-11 LICENSEE TO THE CERTIFIED INSTALLER. POST TENSION RODS SHALL BE 7/16" DIAMETER WITH 1/2" ROLL THREADS CONFORMING TO ASTM A641 (FY = 60000 PSI) AND HAVE STEEL CHEMISTRY SO THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION ROD = .1503 SQUARE INCHES.. BEARING PLATES ARE 1/4' THICK (Fy=50 KSI) SEE SHEET C FOR DIMENSIONS. 1/2" COUPLERS PER ASTM A563 GRADE A. AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED IS DEFINED AS 1/2" MIN. INTO COUPLER. 1/2" NUTS ARE TO BE GRADE 8, PER ASTM A325. 1/2' ALL THREADS PER ASTM A307, GRADE 60. DIRECT TENSION INDICATOR (DTI - COMPRESSIBLE WASHER) IS MANUFACTURED PER ASTM F959. PLASTIC REBAR SADDLES ARE NON—STRUCTURAL. 11. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER SHEET A AND CONFORM TO ASTM A82 LADDER TYPE, 9 GAGE DIAMETER. LAP JOINT REINFORCING ONE FULL CROSS SQUARE (6" MINIMUM LAP). 12. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2" COUPLERS AND STRAIGHT RODS THREADED BOTH ENDS FOR ADDITIONAL LIFTS. RODS SHALL HAVE A MIN. OF 3" 'L' HOOK, WITH 1/2' NUT AT ENO OF TENSION ROD WHERE EMBEDDED IN FOOTING. 13. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND 20' ON CENTER IN STUCCOED WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. POST TENSION ROD SHALL OCCUR WITHIN 12" OF END OF WALL AND 12" EACH SIDE OF CONTROL JOINT. 14. NO COUPLERS MAY OCCUR DIRECTLY BELOW AND 1N CONTACT WITH THE BEARING PLATE. NO BOND BEAM BLOCK MAY BE USED AT PLATE/TENSION LOCATION. 15. TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OPTION; AT CONTRACTOR OPTION, VERTICAL REBAR MAY BE STABBED DOWN INTO THE DIP. 16. A PROTO-11 OTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN THE BEARING PLATE AND NUT WITH THE DTI "TABS" FACING UP AGAINST THE BOTTOM OF THE NUT. THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF FINAL TENSIONING BY A DEPUTY INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS; METHOD 1; VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTD, TABS FACING UP AND COLLAPSED AGAINST NUT WITH NO LIGHT LEAKAGE BETWEEN THE PROTO-11 DTI AND BOTTOM OF NUT. METHOD 2: USE OF A CALIBRATED TORQUE WRENCH TORQUED TO 55 FT -LBS. (DTI MUST STILL BE PLACED WITH METHOD 2. NO VISUAL INSPECTION OF D71 REQUIRED WHEN USING METHOD 2). INSPECTOR SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND INTEGRITY OF MORTAR JOINTS, AND PROVIDE A SIGNED REPORT TO ALL REQUIRED PARTIES. PROTO 11 MASONRY DESIGN IS BASED ON THIS SPECIAL INSPECTION., 17. POST TENSION ROD SPACING IS INDEPENDENT OF DIP SPACING. TOLERANCE FOR DIP SPACING IS ±12' BUT THE NUMBER OF FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL POST TENSION ROD SPACING TOLERANCE IS t8" BUT THE NUMBER OF RODS FOR A GIVEN LENGTH OF WALL MUST REMAIN THE SAME. 18. SEISMIC DESIGN CRITERIA. Ss=2.0. Si=0.749 SOIL CLASS=D (ASSUMED K.C+ILiF69p_ 19. FOUNDATION INSPECTION PRIOR L' L(A>TiO�I ' �TAd€, D SIZE/DEPTH AND CLEANLINESS OF FOUNDATI rAWAQN� BPE� I�EQ�1 S I I VIREt RED It & �SDiT� ° ^O T^ BUILDING &SAFETY DE T. r�f� E S APPROVE® FOR CONS -1 IUCT NT N N FOR CON RUCTION SEALED N `[ Y 8�>9 DATE�B DA S405 m °G A CARUSO g hg! PROT041 TY wALL sYs7Em � * • . TUiZLEY WWW.PROT02.COM sTRUCTU�P ��P SCOTT 4 mp@o@ 41800 CASCADES COURT TEMECULA, CA 92591 ATTN: GARY OTTO gT� �FO� INC. mmee PHI (951) 694-3793 - goryottoWrotois.com OF CAI www.ctsoz.com �. oL'sK„, (NAY OWT BE WSTAUFD DY APPROVED AND C[RTFU DSTAumm) 1.:�»3=s 1' 6. AND If (H= POST—TENS=LE 1 MASOWY WALLS 'LA N STANDARD A. CA JW NUMBER 14 15-9155 "(RACKING DRAWN 1 - -8964 TMH DATE ENGR 08.19.2014 JAC PACKAGE SHEET B THESE DRAWIGS/CALCULATIONS ARE CONSIDERED P_REUMINARY -NOT FOR CONSMKITON OR RECORDING UNLESS THE STRUCTURAL DOW OF RECORD'S SEAL IS AFFIXED MI WTIEN SIGNATURE. TOP OF PROTO If WALL 0 / PROTO-11 / (5) (3) PLAN VIEW (4) (�) (2) Is1 (8) (7) KEY NOTES 1. POST TENSION .ROD. 2. NUT, 3. DIRECT TENSION INDICATOR (DTI). 4. BEARING TOP PLATE. 5. COLLAPSIBLE TABS. 6. MINIMUM TENSION TO 8E 6,000 LBS LOAD AND CONFIRMED BY ONE OF TWO METHODS PER NOTES "B" do "C" BELOW. 7, FILL CAP BLOCK WITH MORTAR. IMMEDIATELY 'FLIP' ONTO ROD. COMPLETELY COVER NUT, ROD AND PLATE WITH MORTAR. 8. CAP BLOCK OF SUFFICIENT SIZE TO COVER PLATE AND ROD. 9. CONTINUOUS HORIZONTAL JOINT REINFORCING. 10. CENTER WEB OR END FACE SHELL BELOW. 11. STEEL PLATE SIZES. A. 4" PROTO 11:1/4"x3"36" B. 4" SLUMP PROTO II -.1/4"x2 1/2"36" C. 6" PROTO 11:1/4'x4 1/2"36" 0. 6" SLUMP PROTO 11: 1/4'x4'36" STEEL PLATES TO BE PLACED AT THE EDGE OF THE CELL SO THAT THE PLATE BEARS FULLY ON THREE SIDES. 12. DO NOT USE BOND BEAM BLOCK AT BEARING PLATE LOCATIONS. CITY OF LA QUIN TA BUILDING & SAFETY DEPT; FOR GR®VED NSTR CTIOf�N OTO` USED TEACH SION ik SLD FA UP AGAINST BC F_ML_ L (NO LIGHT PAI TORQUE OF NUT HAS WN AanM.- -1 B. AS ALTERNATE TO VI AL INSPECTION OF TABS, INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY USE OF A CALIBRATED TORQUE WRENCH. TORQUE NUTS TO 55 FT -LBS. DTI STILL MUST BE PLACED ON ROD IF USING TOROUE-WRENCH METHOD. SEE GENERAL NOTE ON SHEET B. C. SPECIAL DEPUTY INSPECTOR WALL PERFORM A VISUAL INSPECTION WHEN USING THE DTI METHOD TO CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT LEAKS BETWEEN THE TABS AND BOTTOM OF NUT. IF USING TORQUE WRENCH METHOD, DEPUTY INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55 FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED. D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION OF TENSIONING PERFORMED BY ONE OF THE TWO METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR TO PROVIDE A COMPLETED REPORT TO LISTED THESE 0RAW=/CALCULAn0NS ARE CONSIDEKO PR kONARY —NOT FOR COMST K711% OR REMMK UNLESS THE STRUCTURAL EWciNEER OF RECORD'S SEAL IS AFFLXED Ali OTTEN SIDIAME. FOOTING ELEVATION AT POST TENSION ROD PROTO II FENCE WALL QA JI IL I I I II I I Il II' }- --- _// CONCRETE SETTING PAD THICKENED FOOTING TO PROVIDE 3" MIN. COVER AS REQUIRED 7f16" DIA POST TENSION RODS AROUND ANCHOR BOLT AND NUT x EL.EVA110N WALL MEET B CENTER IN 7/16" DIA, POST TENSION RODS (PT) SEE SHEET B CENTER IN WALL — 11 I II �� — THICKENED FOOTING TO PROVIDE 3' MIN_ COVER AS REQUIRED AROUND ANCHOR BOLT AND NUT. L------ 8" 10 SECTION Y BUILD N & SAi=EW DEPT.. AP 6"" R O 7'- PRi TO 11 STANDARD — FOR UONTi AUC T ION LAIQUINTA, CA F SS/ Q N � P jl X20 � DATE JNUMBER OB 0 EALED ON 14-1.15-9155 8�14f14 t10 SCOIe TRACKING 0 DRAWN w S 40 m 14-115-8964 TMH C6 z� 2-TMwuLsYsroes* DATE 08.19.2014 ENCRCARUSO 'JAC — 1p% sTRUCT P 3 TURLEY i✓@Dgge. WWW.PROT02.COM 418M CASCADES COURT TEMECUtA CA 92591 9 TF SCO'I"I' a^ AflN: GARY OTTO PH 951 694-3793 — PACKAGE SHEET OF CAL\F a ww C oz.com v NNS goryotto@prctoo.com (MAY ONLY BE o+srnuw BY APPROVED � m+Tmm MruLERS) S1-2 D ������ r, s'. ASB e' TIBp( Posr-TEN40NFD w9drRY twis — DIM DRAW9fG5/CALgILA'00% ARE CONSIM E0 WEUMINARY -NOT FOR CONSTRUCRpi OR RECO"G UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AMXED. wn1 W"D SIGNATURE