Loading...
BELC2016-002978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: 3 N 1 ELECTRIC INC P O BOX 1487 CHINO, CA 91710 Tw,�p 4 4 Q" - COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BELC2016-0029 78935 HIGHWAY 111 643020029 TARGET / INSTALL (4) CIRCUITS AND (4) OUTLETS $3,000.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C10 License No.: 890507 D'afe:� 3x123 golf; Contractor_ a OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. 'Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under.Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under.penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address: 11111111111111111111 45 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers'• compensation insurance carrier and policy number are: Carrier: _ Policy Number: 2ppy- I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /� r 0 3 23 2� I Applicanth �( \��.N WARNING: FAILURE TO SECURE WORKERSS' CO�ION COVERAGE IS UNLAWFUL, U, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,.the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. ,i, �. Date` 7 / •2of Signature (Applicant or Agent):,• Date: 3/23/2016 Owner: TARGET CORP 1000 NICOLLET MALL TPN 12 MINNEAPOLIS, MN 92253 Contractor: 3 N 1 ELECTRIC INC P 0 BOX 1487 CHINO, CA 91710 (909)930-2181 Uc. No.: 890507 • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers'• compensation insurance carrier and policy number are: Carrier: _ Policy Number: 2ppy- I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /� r 0 3 23 2� I Applicanth �( \��.N WARNING: FAILURE TO SECURE WORKERSS' CO�ION COVERAGE IS UNLAWFUL, U, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,.the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. ,i, �. Date` 7 / •2of Signature (Applicant or Agent):,• DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY. AMOUNT ;' • °> PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # .::CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 DESCRIPTION. ACCOUNT . QTY, AMOUNT PAID _ PAID DATE DEVICES, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY - METHOD -RECEIPT # :.:.. CHECK# CLTD.BY DESCRIPTION ACCOUNT QTY AMOUNT PAID 'PAID DATE DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD ,RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL:. $48.34 $0.00 DESCRIPTION ACCOUNT QTY .. :. AMOUNT, PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD :. RECEIPT #.. CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0:00 TOTALS:00 Description: TARGET / INSTALL (4) CIRCUITS AND (4) OUTLETS CONDITIONS Type: ELECTRICAL Subtype: Status: APPROVED Applied: 3/23/2016 SKH Approved: 3/23/2016 SKH Parcel No: 643020029 Site Address: 78935 HIGHWAY 111 LA QUINTA,CA 92253 Subdivision: PM 30903 Block: Lot: 5 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 FAX EMAIL Details: ELECTRICAL - (4) OUTLETS AND (4) CIRCUITS. 2013 CALIFORNIA BUILDING CODES. 3 N 1 ELECTRIC INC ADDITIONAL SITES CHRONOLOGY CONDITIONS INFORMATION CONTACTS LTD DESCRIPTION ACCOUNT QTY AMOUNT PAID NAME TYPE NAME ADDRESS1. CITY STATE ZIP PHONE FAX EMAIL APPLICANT 3 N 1 ELECTRIC INC P 0 BOX 1487 CHINO CA 91710 CONTRACTOR 3 N 1 ELECTRIC INC P 0 BOX 1487 CHINO CA 91710 OWNER TARGET CORP 1000 NICOLLET MALL TPN 12 MINNEAPOLIS MN 92253 Printed: Wednesday, March 23, 2016 10:43:40 AM 1 of 2 Qq SYSTEMS FINANCIAL INFORMATION LTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY 7BY BSAS 561473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION' $1.00 $0.00 BSA: Printed: Wednesday, March 23, 2016 10:43:40 AM 1 of 2 Qq SYSTEMS DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY DEVICES, FIRST 20 101-0000-42403 0 $24.17 $0.00 DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: TOTALS:• $91.85 $0.00 0• PARENTINSPECTIONS PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG NS (1 WK) JIM JOHNSON 3/23/2016 1 3/23/2016 1 3/23/2016 APPROVED Printed: Wednesday, March 23, 2016 10:43:40 AM 2 of 2� SVSTF. AAS Bin # City of La Quinta Building &' Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # I (� (a - Project Address:'? W 11 ` Owner's Name: A. P. Number: Address: Legal Description: City, ST, Zip: Contractor: 3 � � t► /V L Telephone: Address: '2051 S. $AV.6,M Nqf, Project Description: City, ST, Zip: O-N-1 A %Q CGA. 917 6) 10STAtt., y C;%rLU %V &V% h n Tele P o e: 0 9• b 0 x t State Lic. # :$ Q ' Q City Lic. #; Isar ,.`fnow, eKASI.,V%S Po►v%4L Arch., Engr., Designer: Address: City., ST, Zip: h n : Tele P oe Con tructi n Type: Occupancy: s o Y P Lic. #: Stato ProJecttYPe�circle ne • New Add' A ]tr Repairair Demoo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: 3 O 0 O APPLICANT: DO NOT WRITE BELOW THIS LINE 11 Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2"d Review, ready for corrections./issue Electrical Subcon tactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees LOAD SUMMARY CIRCUIT fl: 0.9 KW CIRCUIT JZ 1.0 KW CIRCUIT #1 0.4 KW CIRCUIT ,#4 0.8 KW TOTAL LOAD: 3.1 KW PROVIDE SPARE CIRCUITS FROM NEAREST ELECTRICAL PANEL WITH AVAILABLE CAPACITY. ! I I I I I y,fj - , i I �_ - - - - - - - - - �- --- -- - - - - - -;- - - - - -- -- a- - -- --- -- -� -- - - - - --- - - - - - -- -- - - - - - rr - - - - - - i i I I I i i - ------,----- -------- I .�k0_ ----------------- i i allti i j I, ! ! . i I I I I I I I I i I I � i I i i I I I I 1 I I I I I I 1 -- -"- 9`% X) Til Ili NU ED L-0 ..Lt,.-... Lam.:._.. ��•,r:�.�. '' ."i Imo''"-' - �'4 aa= � LPHARMACY i I 1 KEY PLAN E-1 NOT TO SCALE = jl' DESCRIPTION .�k0_ DUPLEX RECEPTACLE allti GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE m TWIST LOCK OUTLET ® TELEPHONE OUTLET ® DATA OUTLET 4 JUNCTK>N BOX WITH COVERPLATE R` LIGHT STITCH r _T------------ ------------- --------- --------------- __----__- y - Ll 'I t - - - - -- - - -- ----- - - - - ------------ - - - -- 4 n ❑; ----- 4<i - ---t----- - --- -.------ - - - - - - - --- i I i 2 POWER PLAN E-1 SCALE: 1/4" = 1'-0" I ELECTRICAL GENERAL NOTES 1. ROUTE THE FOLLOWING CIRCUITS THROUGH THE ENERGY MANAGEMENT SYSTEM: A. CEILING RECEPTACLES B. WATER HEATERS C. LIGHTED FIXTURE VALANCES 2. ELECTRICAL CONTRACTOR SHALL TIE BACK ALL LOOSE WRING (INCLUDING LOW VOLTAGE) IN AN ORDERLY FASHION. 3. AVOID RUNNING LOW VOLTAGE WIRE OVER HIGH VOLTAGE WIRING OR LIGHT FIXTURES. 4. PROVIDE CONDUIT FOR ALL WIRING. COORDINATE INSTALLATION AND ROUTING REQUIREMENTS WITH APPROPRIATE INSTALLER(S). 5. UNDER (FLOOR OR IN SLAB CONDUIT SHALL BE METAL WITH CONCRETE -TIGHT COMPRESSION FITTINGS WHERE PENETRATING FLOOR SLAB AND SHALL STUB UP VERTICALLY 90 DEGREES. 6. PROVIDE SINGLE GANG PLASTER FLANGES FOR ALL TELEPHONE AND DATA OUTLET LOCATIONS AT SPECIFIED HEIGHT. 7. ALL ELECTRICAL WORK SHALL BE DONE BY A UCENSED ELECTRICIAN. WORK SHAD. BE DOE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL PLANNER. 8. DO NOT LOAD ANY CIRCUIT BEYOND 80% OF ITS CAPACITY. 9. TRACE OUT ANY AND ALL CIRCUITS BEING TIED INTO TO INSURE THAT THE CIRCUIT IS NOT OVERLOADED. 10. CONTRACTOR SHALL COORDINATE ALL FINAL LOCATIONS FOR POINTS OF ELECTRICAL SERVICE (JUNCTION BOXES, STUB -UPS, RECEPTACLES, TELE/DATA OUTLETS, ETC) WITH EQUIPMENT INSTAU.IER AND CVS REPRESENTATIVE PRIOR TO INSTALLATION. 11. ELECTRICAL CONTRACTOR SHALL LABEL SPARE IN PANEL(S) OF ALL CIRCUITS TO BE ABANDONED FROM REMODEL OF STORE 12. ALL UNUSED WIRING IN CEILING/FLOOR SPACE SHALL BE PULLED BACK TO SOURCE AND REMOVED. 13. REUSE EXISTING CIRCUITS FROM REMOVED EQUIPMENT WHEN POSSIBLE, ABANDONED CIRCUITS SHALL RE REMOVED BACK TO SOURCE ELECTRICAL SYMBOL LEGEND MOUNTING HEKIET IS FROM FINISHED FLOOR TO CENTERLINE OF DEVICE OR OUTLET. HEIGHT MAY VARY TO COINCIDE NINTH BUILDING CONSTRUCTION. SYMBOL DESCRIPTION :0 DUPLEX RECEPTACLE �9 GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE m TWIST LOCK OUTLET ® TELEPHONE OUTLET ® DATA OUTLET 4 JUNCTK>N BOX WITH COVERPLATE $ LIGHT STITCH NOTE: UNLESS OTHERWISE NOTED, ALL OUTLETS do JUNCTION BOXES TO BE LOCATED 18' A.F.F. COLOR OF RECEPTACLES TO BE WHITE. ELECTRICAL LEGEND NOTES (PHARMACY) OP1 INSTALL NEW 20'x20' PLYWOOD,16'x1Cx3.5' WHITE STEEL ENMOSURE (BOSCH), AND INSTALL DUPLEX OUTLET FLIUSH-MOUNT® ABOVE THE PLYWOOD BACK TO EXISTING ELECTRICAL PANEL ONEW DIPLIEX (GFI) OUTLET FOR I I FRIDGE AND MICROWAVE ABOVE COUNTER BACK TO EXISTING P2 ELECTRICAI. PANEL P3 NEW NEMA( TWIST LOCK #6 STRAIDED COPPER WIRE TO EXISTING ELECTRICAL PANEL (VERIFY LOCATION). P4 NEW I.S. RACK; MODIFY AREA AS REQUIRED. P5 NEW POWER POLE. NEW DUPLEX OUTLET INSTALLED 40' A.F.F. FOR NEW FILLMASTER BACK TO EXISTING ELECTRICAL PANEL PES E FILLMASTER IS ABOVE COUNTER, ADJUST RECEPTACLE HEIGHT AS NEEDED. CITY OF LA Quip PA BUILDING & SIEVED APPR FOR CONS RUCTION WZ- NEW POWER POLES W/ JUNCTION BOX FOR Q.A. & FILL STATION BENCH. 2 DUPLEX OUTLETS POWERED BY MALE PUG ON TYPICAL POWER POLE DETAIL NOT TO SCALE ELECTRICAL SCOPE OF WORK 1. INSTALL NEW ELECTRICAL OUTLET, PLYWOOD BACKER AND STEEL ENCLOSURE FOR NEW ALARM PANEL WITHIN EXISTING PHARMACY AS SHOWN. 2. INSTALL NEW ELECTRICAL OUTLETS WITHIN FASTING Rx BREAK AREA AS SHOWN. 3. NEW ELECTRICAL/DATA OUTLETS AT I.S. RACK LOCATION AS SHOWN. 4. INSTALL NEW ELECTRICAL OUTLET AT FILLMASTER LOCATION AS SHOWN. ELECTRICAL SPECIFICATIONS (FERAL PROVISIONS A. GENERAL 1. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. THEY ARE INTENDED TO SHOW THE APPROXIMATE LOCATIONS OF EQUIPMENT AND CONIDUIT. DIMENSIONS GIVEN ON THE PLANS, IN FIGURES, SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED IN THE FIELD. ED(ACT LOCATION OF ALL EQUIPMENT SHALL BE VERIFIED IN THE FIELD AND ROUTING OF CONDUITS SHALL SUIT FIELD CONDITIONS. 2. THE ELECTRICAL DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER. MATERIAL AND LABOR NECESSARY TO THE PROJECT SHALL BE FURNISHED MID INSTALLED EVEN THOUGH NOT SPECIFICALLY MENT100 IN BOTH. LABOR AND/OR MATERIALS NEITHER SHOWN NOR SPECIFIED, BUT OBVIOUSLY NECESSARY FOR THE COMPLETION AND PROPER FUNCTIONING OF THE SYSTEM, SHALL BE: FURNISHED AND INSTALLED BY THE ELECTRICAL. CONTRACTOR AT NO ADDITIONAL COST. 3. ARRANGE ALL EQUIPMENT SUBSTANTIALLY AS SHOWN OIN THE DRAWINGS. MAKE DEVIATIONS ONLY WHERE NECESSARY TO AVOID INTERFERENCE CHECK ALL EQUIPMENT SIZES AGAINST AVAILABLE SPACE PRIOR TO SHIPMENT TO AVOID INTERFERENCE 4. EXAMINE THE WORK OF OTHER TRADES INSOFAR AS THEIR WORK COPIES IN CONTACT WITH OR IS COVERED BY THIS WORW, IN NO CASE ATTACH TO, OR FINISH AGAINST ANY DEFECTIVE WORK OR INSTALL. WORK IN A MANNER WHICH WILL PREVENT PROPER INSTALLATION OF THE WORK OF OTHER TRADES. 5. IT IS THE INTENT OF THESE DRAWINGS THAT THIS BE AA COMPLETE ELECTRICAL. JOB. ANY ERRORS OR OMISSIONS SH AIi IBE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDDING THE JIOB. B. VISIT TO THE SITE I. THIS CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING HIS WORK. THE SUBMISSION OF HIS PROPOSAL SHALL INDICATE SUCH KNOWLEDGE. NO ADDITIONAL. PAYMENT SHAT B: MADE ON CAMS THAT ARISE FROM A LACK OF KNOWLEDGE OF THE EXISTING CONDITIONS. C. CODE AND PERMITS 1. INSTALLATION SAL BE IN FULL ACCORDANCE WITH AUL CODES. RULES AND REGULATIONS OF MUNICIPAL, CITY. COUNTY, STATE AND PUBLIC UTILITIES AND ALL OTHER AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. 2. COMPLY WITH ANY SPECIFICATION REQUIREMENTS THAT ARE IN EXCESS BUT NOT IN CONFLICT WITH CODE REQUIREMENTS. 3. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, PLAN RENEWS AND CERTIFICATES OF INSPECTION IN CONNECTION WITH HIS WORK, REQUIRED BY THE FOREGOING AUTHOR TIES. 4. ELECTRICAL MATERIAL AND EQUIPMENT SHALL BEAR THE UL LABEL.. EXCEPT WHERE UL DOES NOT LABEL SUCH TYPES OF MATERIAL AND EQUIPMENT. WIRE AND CABLE A COLOR CODE CONDUCTORS (EXCEPT CONTROL AND INSTRUMENTATION CONDUCTORS) AS FOLLOWS: 208/120 SYSTEM PHASE A BLACK, PHASE B RED, PHASE C BLUE, NEUTRAL WHITE, GROUND GREEN. I. J12 AND #10 CONDUCTORS SHALL. HAVE CONTINUOUS INSULATION COLOR, AS LISTED ABOVE. 2. CONDUCTORS SHALL. BE SOFT ANNEALED COPPER INSULTED FOR 600 VOLTS UNLESS SPECIFICALLY INDICATED OTHERWISE ALUMI I UMI CONDUCTORS ARE NOT ALLOWED ON THIS PROJECT. B. INSULATION TYPE SHALL BE TYPE THW FOR WIRE SIZES #8 AWG AND LARGER AND THHN OR THW N FOR J I GAWG AND SMALLER. THAN SHAT. NOT BE USED IN WET OR DAMP HOCA IONS. C. FLEXIBLE CORD SHALL BE WAVY DUTY TYPE SO WITH AN EQUIPMENT GROUND CONDUCTOR IN ADDITION TO THE CURRENT CARRYING CONDUCTORS. D. PROVIDE J12 CONDUCTORS, UNLESS OTHERWISE INDICATELD. 1. CONTROL CONDUCTORS SHWA. BE #14 MINIMUM FOR NIEC CLASS I AND 116 FOR NEC CLASS I. E. CONDUCTORS 18 AWG AND LARGER SHALL BE STRAFED.. F. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID. G. INSTALL WIRING IN CONDUIT. H. CONNECT 110 AND SMALLER WIRES WITH CONSTANT PRESSURE EXPANDABLE SPRING TYPE CONNECTORS.'"SCOTCHLOK' BY 3M OR B --CAP BY BUCHMAN. 1. CONNECT 18 AND LARGER WHO WITH COMPRESSION CONNNECTORS OR SPLICES AS MANUFACTURED BY BURNOY OR T&B. J. INSULATE SPLICING CONNECTORS TO AT LEAST 2CM OF 'THE WIRE INSULATION. USE PRE -STRETCHED TUBING CONNECTOR INSULATORS, STM PST FOR 12 AND LARGER CONDUCTORS. K. PULL CONDUCTORS USING RECOGNIZED METHODS AND EQIUPM ENT LEAVING AT LEAST C WIRE AT ALL JUNCTION BOXES FOR CONNECTIOINS. 1. CLEANOUT EACH CONDUIT SYSTEM BEFORE PULLING WIRE. L FORM AND TIE ALL WIRING IN PANEL BOARDS. M. THERE SHALL BE NO W90UT JOINTS OR SPLICES MADE INSIDE SWITCHBOARDS/PANELBQARDS. N. BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHAD. BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE: VOLTAGE DRO'. BRANCH CIRCUITS SHAT, BE INSTALLED WITH WIRES OF SWFFICENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LGADDS DOES NOT EXCEED LIMIT OF 3%. 0. WIRE SIZES SHALL BE BASED ON THE 60 DEGREES C AMPACITIES FOR WIRE SIZES NO. 14-1 A.W.G., AND 75 DEGREES C. AMPACITES', FOR WIRE SIZES j1/0 A.W.G. AND LARGER. CIRCUITS MAY BE M ULTL-PLEXED IN CONDUIT PROVIDED WRIE S PROPERLY DERATED AND CONDUIT SIZED PER CODE UNDER NO CRCUUMSTANCE SHALL MORE THIN (8) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. WRING DEQ A WRING DEVICE COLOR SHALL BE WHITE, UNLESS OTHE:RW!ISE INDICATED. B. PROVIDE TOTALLY ENCLOSED, 20 AMPERE, 120/277 VOLTA, QUIET A/C GENERAL USE SNAP SWITCHES. C. SWITCHES SHALL BE SPECIFICATION GRADE AS MANUFACTLURED BY HUBBELL. P&S, OR LEVITON. D. PROVIDE NEMA CONFIGURATION 5-2oR DUPLEX 125 your GROUNDING TYPE RECEPTACLES RATED FOR 20 AMPERES UNLESS OTHERWWEX INDICATED ON THE DRAWINGS. E RECEPTACLES SHALL BE SPECIFICATION GRADE AS MANUFAACTURED BY HUBBELL, P&S OR LEVITON. F. RECEPTACLES REQUIRING AMPERAGES, VOLTAGES OR CONFIGURATIONS DEFERENT FROM THE DUPLEX CONVENIENCE RECEPTACLES ABOVE SHALL BE AS IMTED ON THE DRAWINGS. G. PROVIDE OTHER RECEPTACLES OF A QUALITY, MATERIAL AIC WORKMANSHIP EQUAL TO THAT SPECIFIED FOR DUPLEX CONVENIENCE RECEPTACLES, H. PROVIDE COVER OR DEICE PLATES FOR OUTLET BOXES AS FOLLOWS UNLESS OTHLRtYNSE NOTED: 1. FINISHED AREAS: THERMOPLASTIC - COLOR TO MATCH DEVICE 2. UNFINISHED AREAS: ZINC COATED SHEET' METAL, ALUMINUM, OR CAST METAL, AS APPROPRIATE FOR THE TYPE OF BOX. 3. TELEPHONE, COMMUNICATION, AND SIGNAL OUTLET PLATES, SHALL MATCH THOSE USED FOR RECEPTACLES AND SWITCHES. ALL OUTLET MMD/OR JUNCTION BOXES SHALL BE COMPLETE WITH A COVER PLATE BY THIS CONTRACTOR. 5. WHERE DEVICES ARE GANGED, THEY SHALL BE INSTALLED UNDER A COMMON COVERPLATE L LOCATE SWITCHES APPROXIMATELY 4'-0' ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN ADA REQUIREMENTS). UNLESS OTHERWISE INDICATED. THE LONG DIMENSION OF THE SWITCHES SH11LL B: VERTICAL J. LOCATE RECEPTACLES APPROXIMATELY 1'-6' ABOVE THE FNUSUNED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS), UNLESS NOTED OTHERWISE. THE LONG DIMENSION of RECEPTACLES SHALL BE VERTICAL. RACEWAYS AND BOXES A. RACEWAYS I. ALL WIRE SHNl BE RUN IN ACCORDANCE WITH CODE IN CORROSION RESISTANT, RIGID, THREADED, METAL CONDUIT OR ELECTRICAL. METALLIC TUBING (E.M.L) UNLESS OTHERWISE SPECIFICALLY STATED HEREIN. a. CONDUIT IN EXTERIOR WALLS, BELOW FLOOR SLAB, OR UNDERGROUND SHALL BE RIGID, THREADED, GALVANIZED, HEAVY WALL TYPE b. CARLON PVC TYPE 40 HEAVY WALL CONDUIT WITH GROUND WIRE MAY BE USED BELOW FLOOR SLAB OR UNDERGROUND IN LIEU OF RIGID, THREADED, GALVANIZED CONDUIT. PVC 40 CONDUIT SHALL NOT BE RUN IN OR ABOVE FLOOR SLAB. PVC CONDUIT SHALL TERMINATE BELOW FLOOR SLAB WITH RIGID, THREADED META. CONDUIT ADAPTER. CONDUIT ABOVE SLAB SHALL BE META.. c. PROVIDE BRANCH CIRCUIT CONDUCTORS THAT ARE TYPE THHIN OR THWN AS REQUIRED. 2. CONDUIT SIZE SHALL BE 3/4' MINIMUM. 3. CONDUIT SHALL BE SECURELY FASTENED IN PLACE 4. ALL CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR MID COUNGS WHEREVER POSSIBLE. EXPOSED CONDUIT IN FINISHED AREAS WILL NOT BE PERMITTED. EXPOSED CONDUIT WILL BE PERMITTED IN UNFINISHED AREAS WITH THE SPECIFIC APPROVAL OF THE ARCHITECT. 5. USE LIQUID TIGHT META. CONDUIT FOR ALL CONNECTIONS TO MOTORS AND OTHER EQUIPMENT SUBJECT TO VIBRATION AND IN AREAS SUBJECT TO MOISTURE 6. SUPPORT RUNS OF CONDUIT AS DETAILED IN THE APPROPRIATE TABLE OF THE NATIONAL ELECTRICAL. CODE (NEC). 7. INSTALL EXPOSED RUNS OF CONDUIT PARALLEL OR PERPENDICULAR To THE WALLS. STRUCTURAL MEMBERS OF INTERSECTIONS OF VERTICAL PLANES AND CEILINGS PROVIDE MIT MK,IE TICS USING FITTINGS OR SYMMETRICAL BENDS. SUPPORT CONDUITS WITHIN 1' OF ALL CHANGES IN DIRECTION. 8. IF A CONDUIT IS SUSPENDED, IT SHAW. BE SUPPORTED ON TRAPEZE HANGERS WHICH USE 'ALL -THREAD' RODS FROM THE STRUCTURAL STEEL THE USE OF CEILING SUPPORT WIRE OR SIMILAR MATERIAL. WILL NOT BE ACCEPTED. 9. INSTALL. FIRE SEAL FITTINGS WHERE CONDUITS PENETRATE CONCRETE FLOOR SLABS OR MASONRY WALLS REQUIRED TO BE FIRE RATED. B. PULL AND JUNCTION BOXES 1. INSTALL PULL AND JUNCTION BOXES WHERE SHOWN ON THE DRAWINGS, AND WHERE REQUIRED FOR CHANGES IN DIRECTION, AT JUNCTION POINTS, AND TO FACIITATE WIRE PULLING. FURNISH BOX SIZES IN ACCORDANCE WITH NEC UNLESS LARGER BOXES ARE INDICATED. 2. PROVIDE STEEL BOXES AND REMOVABLE COVERS OF CODE GAGE, HOT ROLLED SHEET STEEL, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE, FOR ABOVE GROUP WORK FURNISH WEATHERPROOF BOXES WHEN INSTALLED ABOVE GROUND OUTSIDE 3. PROVIDE CAST IRON BOXES, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE WHERE SHOWN ON THE DRAWINGS. FURNISH REMOVABLE COVERS WITH GASKETS AMID STAINLESS STEEL, BRASS OR BRONZE SCREWS. 4. PROVIDE CONCRETE BOXES FOR UNDERGROUND WORK UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FURNISH STEEL FRAMES AND COVERS WITH THE COVER ATTACHED TO THE FRAME WITH HEXAGON HEAD, BRASS OR BRONZE CAP SCREWS, 3/8' DIAMETER. PROVIDE A RUBBER GASKET FOR SEATING- BETWEEN THE COVER AND THE FRAME. PAINT THE COVER WITH TWO COATS OF HEAVY ASPHALTUM. C. OUTLET BOXES 1. USE SHEET STEEL BOXES, ZINC `COATED OR CADMIUM PLATED, FOR CONCEALED INTERIOR WORK 2. USE CAST BOXES, ZINC -CADMIUM FINISH MALLEABLE IRON, FOR EXPOSED INIE210R WORK, � AND FOR EXPOSED OR CONXE/IALLED WORK IN WET, DAMP OR EXTERIOR LOCATIONS. CAST BOXES SHALL BE SERFS FD BY CROUSE HINDS OR APPLEOL 3. WALL BOX SIZES (MINIMUM) SHALL BE a SQUARE X 2-1/2' DEEP WHERE WALL CONSTRUCT" PERMITS. WHERE WALL CONSTRUCTION DICTATES, THE WIDTH WAY BE REDUCED TO 2-1/8' OR 1-1/2' UNDER SPECIAL CONDITIONS. 4. FIXTURE OUTLETS IN CEILINGS (MINIMUM) SHWA. BE a OCTAGONAL X 1 -1/2 - DEEP (4-11/16" OCTAGONAL X 2-1/2' DEEP WHERE REQUIRED To ACCOMMODATE LARGER CONDUIT OR LARGER NUMBER OF WIRES). 5. GANG BOXES SHALL BE ONE PIECE (MINIMUM), 2-1/8' DEEP. 6. PROVIDE CAST IRON, CONCRETE -THE FLOOR BOXES WITH ADJUSTABLE COVERS SET FLUSH AND LEVEL WITH THE FINISHED FLOOR, WITH OUTLETS AS INDICATED ON THE DRAWINGS. PROVIDE HUBBELL #B-2400, 4200, OR 4300 SERIES BOXES WITH LEVELING SCREAMS. FLUSH TYPE COVERS AND OPENINGS TO SERVE OUTLETS USED. FURNISH FLUSH CAPS FOR CLOSING OFF BOX WHEN NOT IN USE. 7. FLUSH MOUNT BOXES IN ALL FINISHED WALLS. INSTALL THE PLASTER RINGS IN DRYWALLED PLASTERED WALLS AND RAISED COVERS AS REQUIRED IN WALLS WITH OTHER FINISHES So THAT THE COVER PLATES FIT TIGHTLY AGAINST BOXES OR RINGS, 3/16' MINIMUM GAPS ARE ALLOWED FOR NONCOMBUSTIBLE WAIS. & ADJUST LOCATION OF OUTLETS IN MASONRY OR TILE CONSTRUCTION TO OCCUR IN THE NEAREST JOINT TO THE HEIGHT SPECIFIED. HEIGHTS SHALL MEET A.D.A. REQUIREMENTS. 9. SUPPORT ALL BOXES TO MAINTAIN PROPER AUGNMENT AND RIGIDITY. 10. CLEAN BOXES OF ALL FOREIGN MATTER PRIOR TO THE INSTALLATION OR WIRING OF DEVICES. 11. MOUNTING HEIGHTS ON THE DRAWINGS ARE TO THE CENTERLINE OF THE BOX UNLESS OTHERWISE NOTED. BASIC ELECTRICAL MATERIALS AND METHODS A MOUNTING ACCESSORIES 1. THIS CONTRACTOR SHALL. FURNISH AND INSTALL ALL ANGLE IRON, CHANNEL RON, RODS, SUPPORTS, HANGERS, CONCRETE OR PLYWOOD REQUIRED TO INSTALL, MOUNT AND SUPPORT ANY ELECTRICAL. EQUIPMENT OR DEVICE CALLED FOR ON THE PLANS. 2. SUPPORTING MATERIAL SHALL BE COMPLETE WITH HANGERS, CONNECTORS, BOLTS, CLAMPS AND NECESSARY ACCESSORIES TO MAKE A COMPLETE INSTALLATION. SUPPORTING MATERIAL SHALL BE GALVANIZED, PANTED OR OTHERWISE SUITABLY FINISHED. PRODUCTS BY BRINKLEY, STEEL CITY OR RACO WILL BE ACCEPTABLE B. DOECU ION 1. THE ELECTRICAL WORK FOR CONSTRUCTION PROPOSED SHALT. CONFORM TO ALL FEDERAL. (OSHA), STATE, ALL SPECIFIC SAFETY REQUIREMENTS AND THE REQUIREMENTS OF THE CURRENT EDITION OF THE NEC. C. MATERIALS AND WORKMANSHIP I. ALL WORK SHALL BE INSTALLED IN A PRACTICAL AND WORKMAN LIKE MANNER, BY MECHANICS SKILLED IN THE SEVERAL TRADES NECESSARY. 2. ALL MATERIALS SWILL BE NEW AND FREE FROM DEFECTS AND SHALL BE THE BEST OF THEIR SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAIINOS TO THE CONTRARY. 3. CONTRACTOR SHALL REMOVE ALL DEBRIS AND EXCESS MA794ALS CAUSED BY HIS WORK. 4. ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OR ETL LIBEL 5. CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIA FOR A PERIOD OF ONE YEAR FROM THE DATE OF BUILDING OPENING AND LEAVE HES WORK IN PERFECT ORDER AT THE COMPLETION. SHOULD DEFECTS DEVELOP WITHIN THE GUARANTEE PERIOD, THE CONTRACTOR SHALL UPON NOTICE OF THE SAME, REMEDY THE DEFECTS AND HAVE AL DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY THE REPAIRS CORRECTED AT HIS EXPENSE TO THE CONDITION BEFORE SUCH DAMAGE. gom Nth T--01867 78935 US HIGHWAY 111 LA QUINTA, CA 92253 PRDJE T TYPE TARGET CAP COD6. 200 M Pf OJWT NMER 96286 0 F�-- AWT• RE\ASIONS: 02-12-2016 PERMIT SET CVS PROJ MANAGER: C. BAILEY DRAWING BY: B. RUELAS DATE: 02-10-2016 NORR JOB NUMBER: JCSR.16.0001.00 TITLE: ELECTRICAL NOTES, POWER PLAN & DETAILS SHEET NUMBER: COMMENTS: E-1 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: 3 N 1 ELECTRIC INC P O BOX 1487 CHINO, CA 91710 Tw,�p 4 4 Q" - COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BELC2016-0029 78935 HIGHWAY 111 643020029 TARGET / INSTALL (4) CIRCUITS AND (4) OUTLETS $3,000.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C10 License No.: 890507 D'afe:� 3x123 golf; Contractor_ a OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. 'Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under.Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under.penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address: 11111111111111111111 45 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers'• compensation insurance carrier and policy number are: Carrier: _ Policy Number: 2ppy- I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /� r 0 3 23 2� I Applicanth �( \��.N WARNING: FAILURE TO SECURE WORKERSS' CO�ION COVERAGE IS UNLAWFUL, U, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,.the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. ,i, �. Date` 7 / •2of Signature (Applicant or Agent):,• Date: 3/23/2016 Owner: TARGET CORP 1000 NICOLLET MALL TPN 12 MINNEAPOLIS, MN 92253 Contractor: 3 N 1 ELECTRIC INC P 0 BOX 1487 CHINO, CA 91710 (909)930-2181 Uc. No.: 890507 • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers'• compensation insurance carrier and policy number are: Carrier: _ Policy Number: 2ppy- I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /� r 0 3 23 2� I Applicanth �( \��.N WARNING: FAILURE TO SECURE WORKERSS' CO�ION COVERAGE IS UNLAWFUL, U, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,.the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. ,i, �. Date` 7 / •2of Signature (Applicant or Agent):,• DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY. AMOUNT ;' • °> PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # .::CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 DESCRIPTION. ACCOUNT . QTY, AMOUNT PAID _ PAID DATE DEVICES, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY - METHOD -RECEIPT # :.:.. CHECK# CLTD.BY DESCRIPTION ACCOUNT QTY AMOUNT PAID 'PAID DATE DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD ,RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL:. $48.34 $0.00 DESCRIPTION ACCOUNT QTY .. :. AMOUNT, PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD :. RECEIPT #.. CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0:00 TOTALS:00 Description: TARGET / INSTALL (4) CIRCUITS AND (4) OUTLETS CONDITIONS Type: ELECTRICAL Subtype: Status: APPROVED Applied: 3/23/2016 SKH Approved: 3/23/2016 SKH Parcel No: 643020029 Site Address: 78935 HIGHWAY 111 LA QUINTA,CA 92253 Subdivision: PM 30903 Block: Lot: 5 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $3,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 FAX EMAIL Details: ELECTRICAL - (4) OUTLETS AND (4) CIRCUITS. 2013 CALIFORNIA BUILDING CODES. 3 N 1 ELECTRIC INC ADDITIONAL SITES CHRONOLOGY CONDITIONS INFORMATION CONTACTS LTD DESCRIPTION ACCOUNT QTY AMOUNT PAID NAME TYPE NAME ADDRESS1. CITY STATE ZIP PHONE FAX EMAIL APPLICANT 3 N 1 ELECTRIC INC P 0 BOX 1487 CHINO CA 91710 CONTRACTOR 3 N 1 ELECTRIC INC P 0 BOX 1487 CHINO CA 91710 OWNER TARGET CORP 1000 NICOLLET MALL TPN 12 MINNEAPOLIS MN 92253 Printed: Wednesday, March 23, 2016 10:43:40 AM 1 of 2 Qq SYSTEMS FINANCIAL INFORMATION LTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY 7BY BSAS 561473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION' $1.00 $0.00 BSA: Printed: Wednesday, March 23, 2016 10:43:40 AM 1 of 2 Qq SYSTEMS DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY DEVICES, FIRST 20 101-0000-42403 0 $24.17 $0.00 DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: TOTALS:• $91.85 $0.00 0• PARENTINSPECTIONS PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG NS (1 WK) JIM JOHNSON 3/23/2016 1 3/23/2016 1 3/23/2016 APPROVED Printed: Wednesday, March 23, 2016 10:43:40 AM 2 of 2� SVSTF. AAS Bin # City of La Quinta Building &' Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # I (� (a - Project Address:'? W 11 ` Owner's Name: A. P. Number: Address: Legal Description: City, ST, Zip: Contractor: 3 � � t► /V L Telephone: Address: '2051 S. $AV.6,M Nqf, Project Description: City, ST, Zip: O-N-1 A %Q CGA. 917 6) 10STAtt., y C;%rLU %V &V% h n Tele P o e: 0 9• b 0 x t State Lic. # :$ Q ' Q City Lic. #; Isar ,.`fnow, eKASI.,V%S Po►v%4L Arch., Engr., Designer: Address: City., ST, Zip: h n : Tele P oe Con tructi n Type: Occupancy: s o Y P Lic. #: Stato ProJecttYPe�circle ne • New Add' A ]tr Repairair Demoo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: 3 O 0 O APPLICANT: DO NOT WRITE BELOW THIS LINE 11 Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2"d Review, ready for corrections./issue Electrical Subcon tactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees LOAD SUMMARY CIRCUIT fl: 0.9 KW CIRCUIT JZ 1.0 KW CIRCUIT #1 0.4 KW CIRCUIT ,#4 0.8 KW TOTAL LOAD: 3.1 KW PROVIDE SPARE CIRCUITS FROM NEAREST ELECTRICAL PANEL WITH AVAILABLE CAPACITY. ! I I I I I y,fj - , i I �_ - - - - - - - - - �- --- -- - - - - - -;- - - - - -- -- a- - -- --- -- -� -- - - - - --- - - - - - -- -- - - - - - rr - - - - - - i i I I I i i - ------,----- -------- I .�k0_ ----------------- i i allti i j I, ! ! . i I I I I I I I I i I I � i I i i I I I I 1 I I I I I I 1 -- -"- 9`% X) Til Ili NU ED L-0 ..Lt,.-... Lam.:._.. ��•,r:�.�. '' ."i Imo''"-' - �'4 aa= � LPHARMACY i I 1 KEY PLAN E-1 NOT TO SCALE = jl' DESCRIPTION .�k0_ DUPLEX RECEPTACLE allti GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE m TWIST LOCK OUTLET ® TELEPHONE OUTLET ® DATA OUTLET 4 JUNCTK>N BOX WITH COVERPLATE R` LIGHT STITCH r _T------------ ------------- --------- --------------- __----__- y - Ll 'I t - - - - -- - - -- ----- - - - - ------------ - - - -- 4 n ❑; ----- 4<i - ---t----- - --- -.------ - - - - - - - --- i I i 2 POWER PLAN E-1 SCALE: 1/4" = 1'-0" I ELECTRICAL GENERAL NOTES 1. ROUTE THE FOLLOWING CIRCUITS THROUGH THE ENERGY MANAGEMENT SYSTEM: A. CEILING RECEPTACLES B. WATER HEATERS C. LIGHTED FIXTURE VALANCES 2. ELECTRICAL CONTRACTOR SHALL TIE BACK ALL LOOSE WRING (INCLUDING LOW VOLTAGE) IN AN ORDERLY FASHION. 3. AVOID RUNNING LOW VOLTAGE WIRE OVER HIGH VOLTAGE WIRING OR LIGHT FIXTURES. 4. PROVIDE CONDUIT FOR ALL WIRING. COORDINATE INSTALLATION AND ROUTING REQUIREMENTS WITH APPROPRIATE INSTALLER(S). 5. UNDER (FLOOR OR IN SLAB CONDUIT SHALL BE METAL WITH CONCRETE -TIGHT COMPRESSION FITTINGS WHERE PENETRATING FLOOR SLAB AND SHALL STUB UP VERTICALLY 90 DEGREES. 6. PROVIDE SINGLE GANG PLASTER FLANGES FOR ALL TELEPHONE AND DATA OUTLET LOCATIONS AT SPECIFIED HEIGHT. 7. ALL ELECTRICAL WORK SHALL BE DONE BY A UCENSED ELECTRICIAN. WORK SHAD. BE DOE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL PLANNER. 8. DO NOT LOAD ANY CIRCUIT BEYOND 80% OF ITS CAPACITY. 9. TRACE OUT ANY AND ALL CIRCUITS BEING TIED INTO TO INSURE THAT THE CIRCUIT IS NOT OVERLOADED. 10. CONTRACTOR SHALL COORDINATE ALL FINAL LOCATIONS FOR POINTS OF ELECTRICAL SERVICE (JUNCTION BOXES, STUB -UPS, RECEPTACLES, TELE/DATA OUTLETS, ETC) WITH EQUIPMENT INSTAU.IER AND CVS REPRESENTATIVE PRIOR TO INSTALLATION. 11. ELECTRICAL CONTRACTOR SHALL LABEL SPARE IN PANEL(S) OF ALL CIRCUITS TO BE ABANDONED FROM REMODEL OF STORE 12. ALL UNUSED WIRING IN CEILING/FLOOR SPACE SHALL BE PULLED BACK TO SOURCE AND REMOVED. 13. REUSE EXISTING CIRCUITS FROM REMOVED EQUIPMENT WHEN POSSIBLE, ABANDONED CIRCUITS SHALL RE REMOVED BACK TO SOURCE ELECTRICAL SYMBOL LEGEND MOUNTING HEKIET IS FROM FINISHED FLOOR TO CENTERLINE OF DEVICE OR OUTLET. HEIGHT MAY VARY TO COINCIDE NINTH BUILDING CONSTRUCTION. SYMBOL DESCRIPTION :0 DUPLEX RECEPTACLE �9 GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE m TWIST LOCK OUTLET ® TELEPHONE OUTLET ® DATA OUTLET 4 JUNCTK>N BOX WITH COVERPLATE $ LIGHT STITCH NOTE: UNLESS OTHERWISE NOTED, ALL OUTLETS do JUNCTION BOXES TO BE LOCATED 18' A.F.F. COLOR OF RECEPTACLES TO BE WHITE. ELECTRICAL LEGEND NOTES (PHARMACY) OP1 INSTALL NEW 20'x20' PLYWOOD,16'x1Cx3.5' WHITE STEEL ENMOSURE (BOSCH), AND INSTALL DUPLEX OUTLET FLIUSH-MOUNT® ABOVE THE PLYWOOD BACK TO EXISTING ELECTRICAL PANEL ONEW DIPLIEX (GFI) OUTLET FOR I I FRIDGE AND MICROWAVE ABOVE COUNTER BACK TO EXISTING P2 ELECTRICAI. PANEL P3 NEW NEMA( TWIST LOCK #6 STRAIDED COPPER WIRE TO EXISTING ELECTRICAL PANEL (VERIFY LOCATION). P4 NEW I.S. RACK; MODIFY AREA AS REQUIRED. P5 NEW POWER POLE. NEW DUPLEX OUTLET INSTALLED 40' A.F.F. FOR NEW FILLMASTER BACK TO EXISTING ELECTRICAL PANEL PES E FILLMASTER IS ABOVE COUNTER, ADJUST RECEPTACLE HEIGHT AS NEEDED. CITY OF LA Quip PA BUILDING & SIEVED APPR FOR CONS RUCTION WZ- NEW POWER POLES W/ JUNCTION BOX FOR Q.A. & FILL STATION BENCH. 2 DUPLEX OUTLETS POWERED BY MALE PUG ON TYPICAL POWER POLE DETAIL NOT TO SCALE ELECTRICAL SCOPE OF WORK 1. INSTALL NEW ELECTRICAL OUTLET, PLYWOOD BACKER AND STEEL ENCLOSURE FOR NEW ALARM PANEL WITHIN EXISTING PHARMACY AS SHOWN. 2. INSTALL NEW ELECTRICAL OUTLETS WITHIN FASTING Rx BREAK AREA AS SHOWN. 3. NEW ELECTRICAL/DATA OUTLETS AT I.S. RACK LOCATION AS SHOWN. 4. INSTALL NEW ELECTRICAL OUTLET AT FILLMASTER LOCATION AS SHOWN. ELECTRICAL SPECIFICATIONS (FERAL PROVISIONS A. GENERAL 1. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. THEY ARE INTENDED TO SHOW THE APPROXIMATE LOCATIONS OF EQUIPMENT AND CONIDUIT. DIMENSIONS GIVEN ON THE PLANS, IN FIGURES, SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED IN THE FIELD. ED(ACT LOCATION OF ALL EQUIPMENT SHALL BE VERIFIED IN THE FIELD AND ROUTING OF CONDUITS SHALL SUIT FIELD CONDITIONS. 2. THE ELECTRICAL DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER. MATERIAL AND LABOR NECESSARY TO THE PROJECT SHALL BE FURNISHED MID INSTALLED EVEN THOUGH NOT SPECIFICALLY MENT100 IN BOTH. LABOR AND/OR MATERIALS NEITHER SHOWN NOR SPECIFIED, BUT OBVIOUSLY NECESSARY FOR THE COMPLETION AND PROPER FUNCTIONING OF THE SYSTEM, SHALL BE: FURNISHED AND INSTALLED BY THE ELECTRICAL. CONTRACTOR AT NO ADDITIONAL COST. 3. ARRANGE ALL EQUIPMENT SUBSTANTIALLY AS SHOWN OIN THE DRAWINGS. MAKE DEVIATIONS ONLY WHERE NECESSARY TO AVOID INTERFERENCE CHECK ALL EQUIPMENT SIZES AGAINST AVAILABLE SPACE PRIOR TO SHIPMENT TO AVOID INTERFERENCE 4. EXAMINE THE WORK OF OTHER TRADES INSOFAR AS THEIR WORK COPIES IN CONTACT WITH OR IS COVERED BY THIS WORW, IN NO CASE ATTACH TO, OR FINISH AGAINST ANY DEFECTIVE WORK OR INSTALL. WORK IN A MANNER WHICH WILL PREVENT PROPER INSTALLATION OF THE WORK OF OTHER TRADES. 5. IT IS THE INTENT OF THESE DRAWINGS THAT THIS BE AA COMPLETE ELECTRICAL. JOB. ANY ERRORS OR OMISSIONS SH AIi IBE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDDING THE JIOB. B. VISIT TO THE SITE I. THIS CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING HIS WORK. THE SUBMISSION OF HIS PROPOSAL SHALL INDICATE SUCH KNOWLEDGE. NO ADDITIONAL. PAYMENT SHAT B: MADE ON CAMS THAT ARISE FROM A LACK OF KNOWLEDGE OF THE EXISTING CONDITIONS. C. CODE AND PERMITS 1. INSTALLATION SAL BE IN FULL ACCORDANCE WITH AUL CODES. RULES AND REGULATIONS OF MUNICIPAL, CITY. COUNTY, STATE AND PUBLIC UTILITIES AND ALL OTHER AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. 2. COMPLY WITH ANY SPECIFICATION REQUIREMENTS THAT ARE IN EXCESS BUT NOT IN CONFLICT WITH CODE REQUIREMENTS. 3. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, PLAN RENEWS AND CERTIFICATES OF INSPECTION IN CONNECTION WITH HIS WORK, REQUIRED BY THE FOREGOING AUTHOR TIES. 4. ELECTRICAL MATERIAL AND EQUIPMENT SHALL BEAR THE UL LABEL.. EXCEPT WHERE UL DOES NOT LABEL SUCH TYPES OF MATERIAL AND EQUIPMENT. WIRE AND CABLE A COLOR CODE CONDUCTORS (EXCEPT CONTROL AND INSTRUMENTATION CONDUCTORS) AS FOLLOWS: 208/120 SYSTEM PHASE A BLACK, PHASE B RED, PHASE C BLUE, NEUTRAL WHITE, GROUND GREEN. I. J12 AND #10 CONDUCTORS SHALL. HAVE CONTINUOUS INSULATION COLOR, AS LISTED ABOVE. 2. CONDUCTORS SHALL. BE SOFT ANNEALED COPPER INSULTED FOR 600 VOLTS UNLESS SPECIFICALLY INDICATED OTHERWISE ALUMI I UMI CONDUCTORS ARE NOT ALLOWED ON THIS PROJECT. B. INSULATION TYPE SHALL BE TYPE THW FOR WIRE SIZES #8 AWG AND LARGER AND THHN OR THW N FOR J I GAWG AND SMALLER. THAN SHAT. NOT BE USED IN WET OR DAMP HOCA IONS. C. FLEXIBLE CORD SHALL BE WAVY DUTY TYPE SO WITH AN EQUIPMENT GROUND CONDUCTOR IN ADDITION TO THE CURRENT CARRYING CONDUCTORS. D. PROVIDE J12 CONDUCTORS, UNLESS OTHERWISE INDICATELD. 1. CONTROL CONDUCTORS SHWA. BE #14 MINIMUM FOR NIEC CLASS I AND 116 FOR NEC CLASS I. E. CONDUCTORS 18 AWG AND LARGER SHALL BE STRAFED.. F. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID. G. INSTALL WIRING IN CONDUIT. H. CONNECT 110 AND SMALLER WIRES WITH CONSTANT PRESSURE EXPANDABLE SPRING TYPE CONNECTORS.'"SCOTCHLOK' BY 3M OR B --CAP BY BUCHMAN. 1. CONNECT 18 AND LARGER WHO WITH COMPRESSION CONNNECTORS OR SPLICES AS MANUFACTURED BY BURNOY OR T&B. J. INSULATE SPLICING CONNECTORS TO AT LEAST 2CM OF 'THE WIRE INSULATION. USE PRE -STRETCHED TUBING CONNECTOR INSULATORS, STM PST FOR 12 AND LARGER CONDUCTORS. K. PULL CONDUCTORS USING RECOGNIZED METHODS AND EQIUPM ENT LEAVING AT LEAST C WIRE AT ALL JUNCTION BOXES FOR CONNECTIOINS. 1. CLEANOUT EACH CONDUIT SYSTEM BEFORE PULLING WIRE. L FORM AND TIE ALL WIRING IN PANEL BOARDS. M. THERE SHALL BE NO W90UT JOINTS OR SPLICES MADE INSIDE SWITCHBOARDS/PANELBQARDS. N. BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHAD. BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE: VOLTAGE DRO'. BRANCH CIRCUITS SHAT, BE INSTALLED WITH WIRES OF SWFFICENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LGADDS DOES NOT EXCEED LIMIT OF 3%. 0. WIRE SIZES SHALL BE BASED ON THE 60 DEGREES C AMPACITIES FOR WIRE SIZES NO. 14-1 A.W.G., AND 75 DEGREES C. AMPACITES', FOR WIRE SIZES j1/0 A.W.G. AND LARGER. CIRCUITS MAY BE M ULTL-PLEXED IN CONDUIT PROVIDED WRIE S PROPERLY DERATED AND CONDUIT SIZED PER CODE UNDER NO CRCUUMSTANCE SHALL MORE THIN (8) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. WRING DEQ A WRING DEVICE COLOR SHALL BE WHITE, UNLESS OTHE:RW!ISE INDICATED. B. PROVIDE TOTALLY ENCLOSED, 20 AMPERE, 120/277 VOLTA, QUIET A/C GENERAL USE SNAP SWITCHES. C. SWITCHES SHALL BE SPECIFICATION GRADE AS MANUFACTLURED BY HUBBELL. P&S, OR LEVITON. D. PROVIDE NEMA CONFIGURATION 5-2oR DUPLEX 125 your GROUNDING TYPE RECEPTACLES RATED FOR 20 AMPERES UNLESS OTHERWWEX INDICATED ON THE DRAWINGS. E RECEPTACLES SHALL BE SPECIFICATION GRADE AS MANUFAACTURED BY HUBBELL, P&S OR LEVITON. F. RECEPTACLES REQUIRING AMPERAGES, VOLTAGES OR CONFIGURATIONS DEFERENT FROM THE DUPLEX CONVENIENCE RECEPTACLES ABOVE SHALL BE AS IMTED ON THE DRAWINGS. G. PROVIDE OTHER RECEPTACLES OF A QUALITY, MATERIAL AIC WORKMANSHIP EQUAL TO THAT SPECIFIED FOR DUPLEX CONVENIENCE RECEPTACLES, H. PROVIDE COVER OR DEICE PLATES FOR OUTLET BOXES AS FOLLOWS UNLESS OTHLRtYNSE NOTED: 1. FINISHED AREAS: THERMOPLASTIC - COLOR TO MATCH DEVICE 2. UNFINISHED AREAS: ZINC COATED SHEET' METAL, ALUMINUM, OR CAST METAL, AS APPROPRIATE FOR THE TYPE OF BOX. 3. TELEPHONE, COMMUNICATION, AND SIGNAL OUTLET PLATES, SHALL MATCH THOSE USED FOR RECEPTACLES AND SWITCHES. ALL OUTLET MMD/OR JUNCTION BOXES SHALL BE COMPLETE WITH A COVER PLATE BY THIS CONTRACTOR. 5. WHERE DEVICES ARE GANGED, THEY SHALL BE INSTALLED UNDER A COMMON COVERPLATE L LOCATE SWITCHES APPROXIMATELY 4'-0' ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN ADA REQUIREMENTS). UNLESS OTHERWISE INDICATED. THE LONG DIMENSION OF THE SWITCHES SH11LL B: VERTICAL J. LOCATE RECEPTACLES APPROXIMATELY 1'-6' ABOVE THE FNUSUNED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS), UNLESS NOTED OTHERWISE. THE LONG DIMENSION of RECEPTACLES SHALL BE VERTICAL. RACEWAYS AND BOXES A. RACEWAYS I. ALL WIRE SHNl BE RUN IN ACCORDANCE WITH CODE IN CORROSION RESISTANT, RIGID, THREADED, METAL CONDUIT OR ELECTRICAL. METALLIC TUBING (E.M.L) UNLESS OTHERWISE SPECIFICALLY STATED HEREIN. a. CONDUIT IN EXTERIOR WALLS, BELOW FLOOR SLAB, OR UNDERGROUND SHALL BE RIGID, THREADED, GALVANIZED, HEAVY WALL TYPE b. CARLON PVC TYPE 40 HEAVY WALL CONDUIT WITH GROUND WIRE MAY BE USED BELOW FLOOR SLAB OR UNDERGROUND IN LIEU OF RIGID, THREADED, GALVANIZED CONDUIT. PVC 40 CONDUIT SHALL NOT BE RUN IN OR ABOVE FLOOR SLAB. PVC CONDUIT SHALL TERMINATE BELOW FLOOR SLAB WITH RIGID, THREADED META. CONDUIT ADAPTER. CONDUIT ABOVE SLAB SHALL BE META.. c. PROVIDE BRANCH CIRCUIT CONDUCTORS THAT ARE TYPE THHIN OR THWN AS REQUIRED. 2. CONDUIT SIZE SHALL BE 3/4' MINIMUM. 3. CONDUIT SHALL BE SECURELY FASTENED IN PLACE 4. ALL CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR MID COUNGS WHEREVER POSSIBLE. EXPOSED CONDUIT IN FINISHED AREAS WILL NOT BE PERMITTED. EXPOSED CONDUIT WILL BE PERMITTED IN UNFINISHED AREAS WITH THE SPECIFIC APPROVAL OF THE ARCHITECT. 5. USE LIQUID TIGHT META. CONDUIT FOR ALL CONNECTIONS TO MOTORS AND OTHER EQUIPMENT SUBJECT TO VIBRATION AND IN AREAS SUBJECT TO MOISTURE 6. SUPPORT RUNS OF CONDUIT AS DETAILED IN THE APPROPRIATE TABLE OF THE NATIONAL ELECTRICAL. CODE (NEC). 7. INSTALL EXPOSED RUNS OF CONDUIT PARALLEL OR PERPENDICULAR To THE WALLS. STRUCTURAL MEMBERS OF INTERSECTIONS OF VERTICAL PLANES AND CEILINGS PROVIDE MIT MK,IE TICS USING FITTINGS OR SYMMETRICAL BENDS. SUPPORT CONDUITS WITHIN 1' OF ALL CHANGES IN DIRECTION. 8. IF A CONDUIT IS SUSPENDED, IT SHAW. BE SUPPORTED ON TRAPEZE HANGERS WHICH USE 'ALL -THREAD' RODS FROM THE STRUCTURAL STEEL THE USE OF CEILING SUPPORT WIRE OR SIMILAR MATERIAL. WILL NOT BE ACCEPTED. 9. INSTALL. FIRE SEAL FITTINGS WHERE CONDUITS PENETRATE CONCRETE FLOOR SLABS OR MASONRY WALLS REQUIRED TO BE FIRE RATED. B. PULL AND JUNCTION BOXES 1. INSTALL PULL AND JUNCTION BOXES WHERE SHOWN ON THE DRAWINGS, AND WHERE REQUIRED FOR CHANGES IN DIRECTION, AT JUNCTION POINTS, AND TO FACIITATE WIRE PULLING. FURNISH BOX SIZES IN ACCORDANCE WITH NEC UNLESS LARGER BOXES ARE INDICATED. 2. PROVIDE STEEL BOXES AND REMOVABLE COVERS OF CODE GAGE, HOT ROLLED SHEET STEEL, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE, FOR ABOVE GROUP WORK FURNISH WEATHERPROOF BOXES WHEN INSTALLED ABOVE GROUND OUTSIDE 3. PROVIDE CAST IRON BOXES, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE WHERE SHOWN ON THE DRAWINGS. FURNISH REMOVABLE COVERS WITH GASKETS AMID STAINLESS STEEL, BRASS OR BRONZE SCREWS. 4. PROVIDE CONCRETE BOXES FOR UNDERGROUND WORK UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FURNISH STEEL FRAMES AND COVERS WITH THE COVER ATTACHED TO THE FRAME WITH HEXAGON HEAD, BRASS OR BRONZE CAP SCREWS, 3/8' DIAMETER. PROVIDE A RUBBER GASKET FOR SEATING- BETWEEN THE COVER AND THE FRAME. PAINT THE COVER WITH TWO COATS OF HEAVY ASPHALTUM. C. OUTLET BOXES 1. USE SHEET STEEL BOXES, ZINC `COATED OR CADMIUM PLATED, FOR CONCEALED INTERIOR WORK 2. USE CAST BOXES, ZINC -CADMIUM FINISH MALLEABLE IRON, FOR EXPOSED INIE210R WORK, � AND FOR EXPOSED OR CONXE/IALLED WORK IN WET, DAMP OR EXTERIOR LOCATIONS. CAST BOXES SHALL BE SERFS FD BY CROUSE HINDS OR APPLEOL 3. WALL BOX SIZES (MINIMUM) SHALL BE a SQUARE X 2-1/2' DEEP WHERE WALL CONSTRUCT" PERMITS. WHERE WALL CONSTRUCTION DICTATES, THE WIDTH WAY BE REDUCED TO 2-1/8' OR 1-1/2' UNDER SPECIAL CONDITIONS. 4. FIXTURE OUTLETS IN CEILINGS (MINIMUM) SHWA. BE a OCTAGONAL X 1 -1/2 - DEEP (4-11/16" OCTAGONAL X 2-1/2' DEEP WHERE REQUIRED To ACCOMMODATE LARGER CONDUIT OR LARGER NUMBER OF WIRES). 5. GANG BOXES SHALL BE ONE PIECE (MINIMUM), 2-1/8' DEEP. 6. PROVIDE CAST IRON, CONCRETE -THE FLOOR BOXES WITH ADJUSTABLE COVERS SET FLUSH AND LEVEL WITH THE FINISHED FLOOR, WITH OUTLETS AS INDICATED ON THE DRAWINGS. PROVIDE HUBBELL #B-2400, 4200, OR 4300 SERIES BOXES WITH LEVELING SCREAMS. FLUSH TYPE COVERS AND OPENINGS TO SERVE OUTLETS USED. FURNISH FLUSH CAPS FOR CLOSING OFF BOX WHEN NOT IN USE. 7. FLUSH MOUNT BOXES IN ALL FINISHED WALLS. INSTALL THE PLASTER RINGS IN DRYWALLED PLASTERED WALLS AND RAISED COVERS AS REQUIRED IN WALLS WITH OTHER FINISHES So THAT THE COVER PLATES FIT TIGHTLY AGAINST BOXES OR RINGS, 3/16' MINIMUM GAPS ARE ALLOWED FOR NONCOMBUSTIBLE WAIS. & ADJUST LOCATION OF OUTLETS IN MASONRY OR TILE CONSTRUCTION TO OCCUR IN THE NEAREST JOINT TO THE HEIGHT SPECIFIED. HEIGHTS SHALL MEET A.D.A. REQUIREMENTS. 9. SUPPORT ALL BOXES TO MAINTAIN PROPER AUGNMENT AND RIGIDITY. 10. CLEAN BOXES OF ALL FOREIGN MATTER PRIOR TO THE INSTALLATION OR WIRING OF DEVICES. 11. MOUNTING HEIGHTS ON THE DRAWINGS ARE TO THE CENTERLINE OF THE BOX UNLESS OTHERWISE NOTED. BASIC ELECTRICAL MATERIALS AND METHODS A MOUNTING ACCESSORIES 1. THIS CONTRACTOR SHALL. FURNISH AND INSTALL ALL ANGLE IRON, CHANNEL RON, RODS, SUPPORTS, HANGERS, CONCRETE OR PLYWOOD REQUIRED TO INSTALL, MOUNT AND SUPPORT ANY ELECTRICAL. EQUIPMENT OR DEVICE CALLED FOR ON THE PLANS. 2. SUPPORTING MATERIAL SHALL BE COMPLETE WITH HANGERS, CONNECTORS, BOLTS, CLAMPS AND NECESSARY ACCESSORIES TO MAKE A COMPLETE INSTALLATION. SUPPORTING MATERIAL SHALL BE GALVANIZED, PANTED OR OTHERWISE SUITABLY FINISHED. PRODUCTS BY BRINKLEY, STEEL CITY OR RACO WILL BE ACCEPTABLE B. DOECU ION 1. THE ELECTRICAL WORK FOR CONSTRUCTION PROPOSED SHALT. CONFORM TO ALL FEDERAL. (OSHA), STATE, ALL SPECIFIC SAFETY REQUIREMENTS AND THE REQUIREMENTS OF THE CURRENT EDITION OF THE NEC. C. MATERIALS AND WORKMANSHIP I. ALL WORK SHALL BE INSTALLED IN A PRACTICAL AND WORKMAN LIKE MANNER, BY MECHANICS SKILLED IN THE SEVERAL TRADES NECESSARY. 2. ALL MATERIALS SWILL BE NEW AND FREE FROM DEFECTS AND SHALL BE THE BEST OF THEIR SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAIINOS TO THE CONTRARY. 3. CONTRACTOR SHALL REMOVE ALL DEBRIS AND EXCESS MA794ALS CAUSED BY HIS WORK. 4. ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OR ETL LIBEL 5. CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIA FOR A PERIOD OF ONE YEAR FROM THE DATE OF BUILDING OPENING AND LEAVE HES WORK IN PERFECT ORDER AT THE COMPLETION. SHOULD DEFECTS DEVELOP WITHIN THE GUARANTEE PERIOD, THE CONTRACTOR SHALL UPON NOTICE OF THE SAME, REMEDY THE DEFECTS AND HAVE AL DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY THE REPAIRS CORRECTED AT HIS EXPENSE TO THE CONDITION BEFORE SUCH DAMAGE. gom Nth T--01867 78935 US HIGHWAY 111 LA QUINTA, CA 92253 PRDJE T TYPE TARGET CAP COD6. 200 M Pf OJWT NMER 96286 0 F�-- AWT• RE\ASIONS: 02-12-2016 PERMIT SET CVS PROJ MANAGER: C. BAILEY DRAWING BY: B. RUELAS DATE: 02-10-2016 NORR JOB NUMBER: JCSR.16.0001.00 TITLE: ELECTRICAL NOTES, POWER PLAN & DETAILS SHEET NUMBER: COMMENTS: E-1