Loading...
BRES2015-041778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&t�t 4 4 Q9,1K& COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT i 111111 11111 -ilii ilii. 28 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/19/2015 Application Number: BRES2015-0417 �,�'"_ Owner: Property Address: 54901 INVERNESS i}s .I ��C� RON NOLTE APN: 775131017 li_ �� I 54,901 INVERNESS Application Description: NOLTE / ATRIUM ENCLOSURE LA QUINTA, CA 92253 Property Zoning: Q, - ,-Application Application Valuation: $18,000.00 Applicant: y ��� Contractor: BOB EDWARDS CONSTRUCTION INCORPORATED _� { 'BOB EDWARDS CONSTRUCTION INCORPORATED 51-455 DESERT CLUB DRIVE z I 51-455 DESERT CLUB DRIVE LA QUINTA, CA 92253 ~ LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed un er rovisions of Chapter 9 (commencing with Section 7000) of Division 3 of e B i ss d Professions Code, and my License is in full force and effect. License!p: B 7 License No.: 6848577 Al`v' Date: Y ` /S Contractor: v OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (760)777-8202 Llc. No.: 684857 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of tl k for which this permit is issued. Mave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree t t, if I should be ome subject to the workers' compensation provisions of Secti n 3 00 r Code, I shall forthwith comply th t sse provisions. //j' L Date: � K `� Applicant: e(/ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances ands jawqrpng to building construction, an hereby authorize representatives of th' it entheabove-menfione,b property for inspection purposes. i; Date: CC' M 1 (5 Signature (Applicant or Agent) FINANCIAL INFORMATION DESCRIPTION :' ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $62.36 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $17.40 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-02400 0 $120.83 $120.83 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $171.14 11/19/15 PAID BY METHOD • RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH Total Paid for ADDITION: $371.73 $371.73 DESCRIPTION -ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 1.5 $105.00 $105.00 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH Total Paid for BLDG CITY STAFF - PER HOUR: $105.00 $105.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPTION ACCOUNT QTY, AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86. 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09 11/19/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH . ..... g2 tbESCFtIPTION jW7 �ACGOUNT' u+ PROPAI T',igw--Vi,7T 0 --49 PAID 71 DATE APPLIANCE REPAIR/ALTERATION PC.. 101-0000-42600 0 $4.83 $4.83 11/19/15 PAI�BYsxxMETHODS I M MET gp, BY_ z 01"All }CLTD BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH Total Paid for MECHANICAL: $16.92 $16 r .92 -DESC :RIPTIONi 4- cmy,MOUNTVis; �Z PAID PAID DATE. ®R ROOF L DRAIN 101-0000-42401 0 $12.09 -$12.09 11/19/15 AID it. METIOD_�.REC 4 ft�, 50 MIPT� CHECK CLTMBY�mt Y, $4. q", if,;r -------- M S.74urN 41�577, BOB EDWARDS CONSTRUCTION INCOR - CHECK R11024 20926' SKH I w SCRI TO C q N Ti, ACCOUNT 'ran' IOUNIN NRL, To I OAT RE. - SRI m 4 :PAID ROOF DRAIN PC 161_0000_42 600 01 -$12.09 $12.09 11/19/15 'Aidby -Y P -0 16, MET HOD N", A 'A' rij CHECK" ,gj:L Z - A BOB EDWARDS CONSTRUCTION INCOR CHECK R11024 20926 SKH Total Paid for PLUMBING FEES: $24.18 $24.18 T DESCRIPTION. ME ��. Rfi ig1f, '!Nl %QT Yji,4� -i -4107 NT LR Li, 'g , gm - it E�; CA 11,47 PAID DATE 2i . ; -ii-4ACCOUNf ""R": i'�`6. n ; gPAIE i -7 SMI - RESIDENTIAL 101-0000-20308 0 $.2.34 $2.34. •11/19/15 1 4; "'V 1 A PAID " 14,R M!CHEC ; � MU M'E BOB EDWARDS CONSTRUCTION INCOR CHECK. R11024 20926 SKH Total Paid for STRONG MOTION -INSTRUMENTATION SMI: $2.34 $2.34 TTALS:'�,.:. $714.06� O $714.06 Description: NOLTE / ATRIUM ENCLOSURE Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED Applied: 10/30/2015 SGU Approved: 11/16/2015 LUR Parcel No: 775133017 Site Address: 54901 INVERNESS LA QUINTA,CA 92253 Subdivision: TR 20717-2 SEE ASSR MB 769 PGS 3134 Block: Lot: 9 Issued: 3536 ACTION DATE COMPLETION DATE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $18,000'.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 BOB PICKED UP SCHOOL -FEE LETTER Details: ATRIUM ENCLOSURE(133 SQ FT) W/ (2) NEW SKYLIGHTS. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE STEPHANIE GUMPERT 11/19/2015 11/19/2015 BOB PICKED UP SCHOOL -FEE LETTER PLAN CHECK COMMENTS FROM CONSULTANT JIM JOHNSON 11/12/2015 11/12/2015 RECEIVED PLAN CHECK SENT TO STEPHANIE GUMPERT 10/30/2015 10/30/2015 SENT TO YOUNG. DUE BACK 11-16-15. OUTSIDE PC PLAN CHECK SUBMITTAL STEPHANIE GUMPERT 10/30/2015 10/30/2015 RECEIVED CONDITION DATE DATE DATE CONTACT STATUS REMARKS NOTES 7 TYPE ADDED REQUIRED SATISFIED NEED LETTER FROM HOA AND SCHOOL FEE READY TO ISSUE LUIS URIBE 11/16/2015 11/16/2015 11/19/2015 COMPLETE CHECKLIST LETTER. Printed:. Thursday, November 19, 2015 1:45:09 PM 1 of 4 Sys -rams Printed: Thursday, November 19, 2015 1:45:09 PM 2 of 4 SYSTEMS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT BOB EDWARDS CONSTRUCTION 51-455 DESERT CLUB LA QUINTA CA 92253 INCORPORATED DRIVE CONTRACTOR BOB EDWARDS CONSTRUCTION 51-455 DESERT CLUB LA QUINTA CA 92253 INCORPORATED DRIVE OWNER RON NOLTE 54901 INVERNESS LA QUINTA CA 92253 FINANCIAL • •• DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE, # RECEIPT CHECK # METHOD PAID BY CLTD . BOB EDWARDS ADDITION, EA 101-0000-42400 0 $62.36 $62.36 11/19/15 R11024 -20926 CHECK CONSTRUCTION SKH ADDITIONAL 500 SF INCOR BOB EDWARDS ADDITION, EA 101-0000-42600 0 $17.40 $17.40 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH ADDITIONAL 500 SF PC INCOR BOB EDWARDS ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH INCOR ADDITION, FIRST 100 SF . BOB EDWARDS 101-0000-42600 0 $171.14 $171.14 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH PC INCOR Total Paid for ADDITION: $371.73 $371.73 HOURLY PLAN CHECK - BOB EDWARDS 101-0000-42600 1.5 $105.00 $105.00 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH YES INCOR Total Paid for BLDG CITY STAFF - PER HOUR: $105.00 $105.00 BOB EDWARDS BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH INCOR Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA:' Printed: Thursday, November 19, 2015 1:45:09 PM 2 of 4 SYSTEMS I. INSPECTIONS Printed: Thursday, November 19, 2015 1:45:09 PM 3 of 4 CRWIYSTEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BOB EDWARDS RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH 1,000SF INCOR BOB EDWARDS RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH 1,000SF, PC INCOR Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 APPLIANCE BOB EDWARDS REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH INCOR APPLIANCE BOB EDWARDS REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $4.83 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH INCOR Total Paid for MECHANICAL: $16.92 $16.92 BOB EDWARDS ROOF DRAIN 101-0000-42401 .0 $12.09 $12.09 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH INCOR BOB EDWARDS ROOF DRAIN PC 101-0000-42600 0 $12.09 $12.09 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH INCOR Total Paid for PLUMBING FEES: $24.18 $24.18 BOB EDWARDS SMI - RESIDENTIAL 101-0000-20308 0 $2.34 $2.34. 11/19/15 R11024 20926 CHECK CONSTRUCTION SKH -INCOR Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.34 $2.34 TOTALS:0. $714.06 I. INSPECTIONS Printed: Thursday, November 19, 2015 1:45:09 PM 3 of 4 CRWIYSTEMS " Permit Details PERMIT NUMBER BRES2015�=041.7r t • City of La Quinta b �x r REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE 1ST BLDG NS (2 WK) LUIS URIBE 10/30/2015 11/16/2015 11/16/2015 APPROVED NEED SCHOOL FEE LETTER AND HOA LETTER. 1ST BLDG STR (2 YOUNG 10/30/2015 11/16/2015 11/10/2015 READY FOR APPROVAL WK) ENGINEERING DOC Printed: Thursday, November 19, 2015 1:45:09 PM 4 of 4 SYSTEMS ATTACHMENTS Attachment Type CREATED. OWNER. DESCRIPTION' PATHNAME SUBDIRt ETRAKIT ENABLED+ 1ST REVIEW - NEW CITY DOC 11/10/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0417 (ist).pdf DOC 11/16/2015 LUIS URIBE SCHOOL FEE LETTER BRE52015-- 0 • SCHOOL FEE LETTE ETTER.pdf Printed: Thursday, November 19, 2015 1:45:09 PM 4 of 4 SYSTEMS Din # City of La Quinta Building 8r Safety Division P.O. Box 1504, 78-495 Calle Tampico La QuInta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Lel �Project Address: 54-901 Inverness- owners Name: Ron & Carol Nolte • A. P. Number: -.775-131-016 Address: 54-901 Inverness Legal Description: City, ST, Zip: La Quinta, CA 92253 Contractor: Bob Edwards Construction ( -2267y. RM Address: 51-455 Desert Club Drive Project Description: City, ST, Zip: La Quinta, CA 92236 ',Proposed Atrium Enclosure (133 sq.ft ).. Telephone: 760-771-4202 w Proposed (2).5252 skylights. State Lic. # Arch., Engr., Designer: Gabri el.Rios.. is Address: 49901 Cinnabar Ln. . City, ST, Zip:.Coachella, CA 92236 Telephone: 760-485�7431 State Lic.#: -M Xi -on struction Type: V-13 occupancy: R-3 Project type (circle one): New Alter Repair Demo Name of Contact Person: Gabriel Rios -Sq. Ft.: 133 s.f. # Stories: 1 # Units: Telephone # of Contact Person: .760-48577431 Value of Pr6iect: $18,000.00 APPLICANT; DoL.N0T,wRITE BELOW THIS LINE N Submittal Req'd Rec'd TRACMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready -forcormetions Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance. Mfle 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan :21 Review, ready for corrections/issue Subcontactor List Called Contact Person do umbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted radi, IN HOUSE:- 7r0 Review, ready for corrections/issue mpact Fee Planning Approval Called Contact Person V I.P.P. Pub. Wks. Appr Date of permit Issue C . Scloodl Fees Total Permit Fees CO"4" Valley Unified School District ' This Box For Dlstrict Use Only 83-733 Avenue 55, Thermal, CA. 92274 DEVELOPER FEES PAID kM. (760) 3198-5909 — Fax (760).398-1224 '1 AREA: AMOUNT LEVEL ONE AMOUNT:- LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND: AMOUNT: DATE: RECEIPT:" CHECK-#: -' INITIALS -' CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: PGA W s ' Date. • November 19, 2015 Owner's Name: Ron & Carol Nolte: Phone No. Project Address: ' 54-901 Inverness, LaQuinta . Project Description: Atrium Enclosure APN: 775-131-016 Tract #:' Lot #'s Type of Development: Residential . ::XX " ;'Commerciat Industrial. Total Square Feet of Building Area:.. 130 ' Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorizedsign behalf o owner/developer. Dated: November 19, 2015.: Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING:. (CIRCLE ONE) Education Code Gov. Code - Project. Agreement Existing Not Subject to Fee 17620 65995 Approval + Prior to 1/1/87. Requirement Number of Sq.Ft. 133 Pursuant to AB 181 any room additions_ or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile Amount per.Sq.Ft. $0.00 homes being relocated within the same school district's Amount Collected • $0.00 ,jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by Laurie Howard, Secretary Signature: CXGZ NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEESAAND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"),.of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with.section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such.Fees or. the:validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As is the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the, date *of,issuance. Extension will be, granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/cellilicate ofcomplian' e* fonn updated 3-2007. RECEIVED 11/2010 NOV 1 9 2015 . CITY OF LA QUINTA COMMUNITY DEVELOPMENT PGA WEST t ; Page l of 2 RESIDENTIAL ASSOCIATION, INC. RECEIVED October 20, 2015 NOV 19 2015 r. Y CITY OF LA QUINTA , C5Mr.-& Mrs. Ron Nolte COMMUNITY DEVELOPQIMENr . 54-901 Inverness z F , La Quinta, CA 92253 - - RE: 54-901 Inverness - PRELIMINARY SUBMITTAL Atrium Enclosure with Skylight Dear Mr. & Mrs. Nolte,"" The Architectural Committee has reviewed your preliminary Architectural Variance submittal for the proposed atrium: enclosure with a`skylight as shown on Sheets T1.0, A0.1, A1.0 dated 9/25/15; A2.0 & A2:1 dated 9/24/15 and A3.0 dated 9/25/15 dated, prepared by Rios Designs. ' The_proposed scone of work is'conceptually acceptable, in accordance with the Architectural - Guidelines, Homeowner's Association CC&R's and Maintenance and Agreement. The vroiect is not approved for construction until a. complete final set of drawings and specifications with the city stamp of approval are provided for the Committee's review. The following conditions and/or requirements are applicable: 1`. The new foam roofing area should match the existing roofing system, material, specifications and warranty.. The transition of new foam roofing to existing sloping tile and existing flat roofs is critical, if applicable. - The Polyurethane Roof Coating Contractor is to provide a compliance letter and warranty. 2. All new roof drains. are to be installed per code with approved connections and overflow provisions. , 3. The skylight curb and framing should not , extend .the height of the skylight to be within the sight line from the adjacent common area. 4. The homeowner is 100 percent responsible 'for.- this installation and its repair, maintenance and water proofing requirements of the roofing and skylights. 5. The HOA will conduct a pre -installation inspection of the'roof. When the installation is completed, and prior to submitting a Notice of Completion form, please contact the HOA . Maintenance. Manager, William Aceves, to arrange for an inspection and water test to verify proper drainage; free of unacceptable ponding. 6. The roofing contractor must repair any'dainage to the tile, roofing paper or foam_ roofing in construction access and work areas. 7. A City of La Quinta Stamped set of drawings is required for the atrium enclosure and the skylight prior to starting any work: 8. A copy of the signedinspection card(s) is to be submitted with the Notice of Completion form and the Contractor's Notice -of Completion- Certification Letter -(enclosed)- at- the - completion of the project. 7 9. The HOA is not responsible for damage to the skylights due to golf balls or other causes. ` 54-320 Southern Hills, La Quints, California 92253-5665, Telephone 760-771"-1234 FAX 760-771-5125 Page 2 of 2 . 10. A Maintenance and IndemnityyA Bement shall be signed prior to the start of work and reviewed at the completion of the project. Same shall delineate all applicable work, which current and future owners shall be compelled to solely maintain and/or replace as needed and be responsible for any damage, including water intrusion, which may occur as a result of said installation. The document shall be recorded with the County of Riverside and runs with the land. We reserve the right to make a final inspection of this change to make sure that it matches the original request. An approval is based only on the aesthetics of your proposed plan and should not be taken as any certification as to the construction worthiness or structural integrity of the proposed change. We appreciate your cooperation in submitting this request for approval. If I may be of further assistance, please contact me at the HOA office, (760) 771-1234, Extension 15. Sincerely, Ke y McGalliard Operations Manager For the Architectural Committee KM/bvf Enc. 1 cc: Architectural Committee PGA WEST RESIDENTIAL ASSOCIATION, INC, To: PGA West Residential Association, Inc. Architectural Committee c/o PGA West Residential Association,,lnc. t - RE: Notice of Completion Certification Letter for:,, Homeowner Name & Address Homeowner Signature r Date Project Name Dear Members of the Committee:; This letter acknowledges our compliance with the'plans and, specifications submitted and approved for the architectural variance at this address. , We also certify that all the work performed is according to the building code and approved by the local building department. -Any changes to the original plan and architectural request'have been resubmitted and approved. r , This information is submitted in •conjunction. with the owner's 'Notice of Completion' document. ' Contractor Signature Date Contractor Company 54=320-So-Otfie rn Hills;-LaFQainta-California-92253=5665; Telephone 76.0=771=1234 -FAX -760=7-71=-5-12-5--- --- BUILDING ENERGY ANALYSIS REPORT PROJECT: Nolte Residence 54-901 Inverness -La- Quinta, CA Project Designer: gp�Np & L'a, QU'NT P� SAFETY DEP • t R cp ® VEF T ..�oSTRUCTI p DATE N �BY Report'Prepared by: - Joan D. Hacker Insu-form, Inc.. 77810 Las Montanas Road, Suite 201 - Palm Desert, Ca 9221.1 , 760-345-1352 . - Job. Number: . - of �,QE�QMEN,t Date: GOO N�ry o 10%25/2015 , The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. ` Ener Pro 6.7 by Ener Sof User Number: 2655 ID: �' � �.. � ` . ,. �' t � _ 1 .. , �' � �.. � ` . ` �' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CF1 R -PRF -01 Page 1 of 9 GENERAL INFORMATION ENERGY USE SUMMA 01 Project Name Single Fam Detached 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 54-901 Inverness Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2979 15 Number of Zones 2 16 Slab Area (ft2) 2979 17 >_ umber of Stories 1 18 Addition Cond. Floor Area 133 19 fn r u al Gas Available Yes 20 Addition Slab Area (ft2) 133 21 1.1 -- T4nPercentage (%) 14.4% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 13 m 03 This building incorporates one or more Special Features shown below 0 II - YJ -ftv-1I Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 HERS Provider: Report Generated at: 2015-10-25 17:19:40 ENERGY USE SUMMA 04 05 0 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 20.35 20.12 0.23 1.1% Space Cooling 350.45 350.67 -0.22 -0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 8.62 8.62 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 379.42 379.41 0.01 0.0% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 HERS Provider: Report Generated at: 2015-10-25 17:19:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD ' M CF1 R -PRF 01 ,M Project Name: Single Fam Detached • - Calculation Datelrime: 17:18, Sun, Oct 25, 2015 4 Page 2 of 9 = - ` Calculation Description: Title 24 Analysis ' Input File Name: Nolte Exist Addition.xml, REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling • Window overhangs and/or fins , � t _ 3• R n ' � r ,• A t l' ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by ani, 1.,. - I - on-site renewable energy system,, y -,_ Reference Energy Use . Energy Design Rating,.,,,i 'Margin Percent Improvement Total Energy (kTDV/f2-yr)• 421.32' :4211.3l 0.01 J. 0.0% r ti 4, .. includes calculated Appliances and Miscellaneous Energy Use (AMEU) -• BUILDING' FEATURES INFORMATION �, t `S - •s<: a 01 . 02 03 04 05 :. 06 07 , Zone Name ' Number of Dwelling Zone Floor Area "T(ft2) Avg. Ceiling Height Number of Ventilation Number of Water Project Name ` Conditioned Floor Area (ft2) Units- Number of Bedrooms Number of Zones Cooling Systems Heating Systems Single Fam Detached 2979 1' -' c6 2 • 0 - 1 , a 3 ZONE INFORMATION -. Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance - 01 02 03 = - 04 . 05 ` 06 07 Zone Name Zone Type 'HVAC System Name -, Zone Floor Area "T(ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Living Conditioned Living Zonet 2846 91 DHW Sys 1 Addition Conditioned Living Zone1 133 9 DHW Sys 1 ' x Registration Date/Time: - HERS Provider Report Version - CF1R-08252015-744 Report Generated at: 2015-10-25 17:19:40. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CF1 R -PRF -01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05- 06 06 07 08 01 02 03 04 05 06 07 08 09 10 Name Zone Construction .Azimuth Orientation Gross Area (W) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition Front Wall Existing Living Default Wall 1978 to 1991 270 Front 3000 16 90 Existing No Left Wall Existing Living Default Wall 1978 to 1991 0 Left 2000 202.777 90 Existing No Rear Wall Existing Living Default Wall 1978 to 1991 90 Back 3000 176.262 90 Existing No Right Wall Existing Living Default Wall 1978 to 1991 180 Right 2000 0.1 90 Existing No Roof 3 Existing LivingDefault Roof 1978 to Pres to Presi 2829.2 Existing No Front Wall 2 Addition R-13 Wall1 ` 270 Front 600 Addition 90 New N/A Left Wall 2 Addition R-13 Wall1 0 Left 800 - ' 90 New N/A Rear Wall 2 Addition R-13 Wall1 90 Back 800 90 New N/A Right Wall 2 Addition R-13 Wall1 180 Right 800 90 New N/A OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05- 06 06 07 08 09 10 11 12 •,13 Radiant Statu Verified Existing Name Construction Type Roof Roof Reflectance Framin Barrier Verified s Condition Attic Existing. Living Orientatio Area Skylight 'Roof Rise Roof 'Roof Reflectan Roof g Existing Name Zone Type n (W)' Area (ft2).. (x in 12) Pitch Tilt(deg) ce Emittance Factor - Status Condifion Roof Existing Living Default Roof 1978 Front 16.9 16.8 0 0 0 0.1 0.85 0.1 Existing No to Presi Roof 2 Addition R-19 Roof front 133 16.8 0 0 0 0.9 0.9 0.1 New N/A ATTIC 01 02 03 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic Existing. Living Attic RoofExisting Living Ventilated 0 0.1 0.85 No No Existi No ng Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-30-25 17:19:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CF1 R -PRF -01 Page 4 of 9 WINDOWS ' 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (W) U -factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Front -270) 8.0 1.0 1 8.0 0.71 0.73 Insect Screen (default) Existing No Window 2 Front Wall (Front -270) 8.0 1.0 1 8.0 0.71 0.73 Insect Screen (default) Existing No Window 3 Left Wall (Left -0) 8.0 6.8 0.982 53.4 0.71 0.73 Insect Screen (default) Existing No Window 4 Left Wall (Left -0) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 5 Left Wall (Left -0) 2.0 4.0 3 24.0 0.71 0.73 Insect Screen (default) Existing No Window 6 Left Wall (Left -0) 1.0 6.0 1 6.0 1 0.71 0.73 Insect Screen (default) Existing No Window 7 . Left Wall (Left -0) 5.0 6.8 0.982 33.4 0.71 0.73 Insect Screen (default) Existing No Window 8 Left Wall (Left -0) 1.0 6.0 1 6.0 0.71 0.73 Insect Screen (default) Existing No Window 9 Left Wall (Left -0) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 10 Rear Wall (Back -90) 2.0 4.0 1 8.0 0.71 0.73 Insect Screen (default) Existing No Window 11 Rear Wall (Back -90) 2.0 4.0 1 8.0 0.71 .0.73 Insect Screen (default) Existing No Window 12 Rear Wall (Back -90) 8.0 6.8 0.982 53.4 0.71 0.73 , Insect Screen (default) Existing No Window 13 Rear Wall (Back -90) 8.0 6.8 0.982 53.4 0.71 0.73 Insect Screen (default) Existing No Window 14 Rear Wall (Back -90) 8.0 6.8 1 0.982 53.4 0.71 0.73 Insect Screen (default) Existing No Skylight Roof (Front -270) 1 ' 16.8 0.40 0.28 None New N/A Skylight 2 Roof 2 (Front -270) 1 16.8 0.40 0.28 None New N/A Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-10-25 17:19:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 .10 11' 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DIstL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1, 2 2 0 4 0 0.1 0 4 0 0.1 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 •0 0 0- 0 0 0` Window 4 2, 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2` ' 0" 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0, 0 0 0 0 0 0 0. Window 7 `° 2•, 0.1 2 2 0 0 0 0 0 0 0 0 01' Window 8 2 0.1 2 2 0 0 0 0 0 0 0. 0, 0 Window 9 2 0.1 ' 2 2 -0 0 01 0 0 0 0 0 0 Window 10•" 2 0.1 2 2 0 0 0 w 0 0 0 0 0 0 Window 11 2 0.1 ••2 ` •' 2 0' 0 0 0 0: 0" 0 0 0 Window 12 2 0.1 2 2 0 4 01 0.1 - 0 4 0 0.1 0 Window 13 2 0.1 2 2. 0 0 0 0 0 0 0 0 0 Window 14 ' 2 0.1 2 2 0, 0 0 0 0. 0' 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-10-25 17:19:40 r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CF1 R -PRF -01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS - 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity 'Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 1 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd Addition 133 1 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic RoofExisting Living Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board y. • Cavity/Frame: R-11 /2x4 • Exterior Finish: Wood Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 ® 16 in. O.C. R 11, 0.103 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below ' : Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2k4 ® 16 in. O.C. R 19 0.049 • Over Floor Joists: R-9.9 insul. • Inside Finish: Gypsum Board - • Cavity/Frame: R -19/2x4 . • Roof Deck: Wood Siding/sheathing/decking Default Roof 1978 to Presl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.061 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Cavity/Frame: R -13/2x4. " -. E Exterior Finish: Wood R-13 Wall1 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking - Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x8 • Roof Deck: Wood Siding/sheathing/decking - Above Deck Insulation: R5 Sheathing R-19 Roof Cathedral Ceilings Wood framed Ceiling 2x8 @ 16 in. O.C. R 19 0.042 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ftZ) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab Existing Living 2846 1 None 0.8 No Existing No Slab -on -Grade Addition 133 1 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 duality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards- 2013 Residential Compliance , Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-10-25 17:19:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CFI R -PRF -f)1 Page 7 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal). Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.6 EF 43000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION - 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 " Heating System Cooling System Distribution Fan floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Living Zone1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2979 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-25 17:19:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Datelrime: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml „ CF1 R -PRF -01 Page 8 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed . Verified Duct Location • Name System Type -EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond -Split air conditioning J 10 12 No No N/A Location system Status Condition Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 4. 03 ' 04 05 06 07 08 09 . 10 Duct Leakage Target (%). . Verified Duct Location • Verified Duct Design Return Supply Insulation Supply Duct Return Duct_ ' Verified Existing HERS Name = Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not ,1. 8.0 ' Attic , Attic None - Existing • No N/A System 1 specified)- � - . - - - HVAC DISTRIBUTION:- HERS VERIFICATION 01 02 03 04. 05 06 Name Duct Leakage -Verification Duct Leakage Target (%). . Verified Duct Location • Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A ' ' IAQ (indoor Air Quality) FANS _ 01 02 03 04 OS Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) „HERS Verification t SFam IAQVentRpt 0 " Default 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-25 17:19:40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 17:18, Sun, Oct 25, 2015 Calculation Description: Title 24 Analysis Input File Name: Nolte Exist Addition.xml CF1 R -PRF -01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan D. Hacker Company: Signature Date: Insu-form, Inc. 10/25/2015 Address: CEA/HERS Certification identification (If applicable): 77810 Las Montanas Road, Suite 201 City/StatePfIi m Desert, Ca 92211 y .. Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT " I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance. are consistent with the information vided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit appli ion. - Responsible Designer Name: Responsible Designer Signature: Gabriel Rios Company: Date Signed: Rios Designs 10/25/201 Address: License: 49-901- Cinnabar Lane N/A City/State/Zip: Phone: Coachella, CA 92236 (760) 485-7431 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-10-25 17:19:40 'RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Nolte Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 10/25/2015 Project Address 54-901 Inverness La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,979 Addition 133 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 2,846 Perim = 1' Existing Wall Wood Framed R11 9,605 Existing Roof Wood Framed Attic R 19 2,829 Existing Demising Wood Framed R 13 1 Existing Wall Wood Framed R 13 3,000 New Roof Wood Framed Rafter R 19 116 Rigid=R-5.0 Cool Roof New Slab Unheated Slab -on -Grade - no insulation 133 Perim = 1' New FENESTRATION I Total Area: 429 Glaing Percentage: 14.4 New/Altered Average U -Factor: 0.40 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (W) 8.0 0.710 0.73 2.0 4.00/4.00 Bug Screen Existing Front (W) 8.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 202.8 0.710 .0.73 2.0 none Bug Screen Existing Rear (E) 122.8 a 710 0.73 2.0 none Bug Screen Existing Rear (E) 53.4 0.710 0.73 2.0 4.00/4.00 Bug Screen Existing Skylight 16.8 0.400 0.28 none none None New Skylight 16.8 0.400 .0.28 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic 8.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.7 by Ener Soft User Number: 2655 RunCode: 2015-10-25717:22:46 ID: Pae 12 of 17 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the comDliance aDDroach used. Exceptions may aDDly. Review the respective code section for more information. Building Envelope Measures: § 110.6(a)l : Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. §I50.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and fight -fitting damper or a combustion -air control device. § 150.0(e)l C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central fumaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § I50.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 15 0.0 h 2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00)1 A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.06)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary 150.0(j)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure> 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § I50.00)3B: or Class H vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 18113 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § I50.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0(m)] 2. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. § 150.0(0)] A: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § I I0.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat t setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary §I I0':4(b)I Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § I I0.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - med to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k) IC: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). §150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary �. a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is prograrnmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, 130.0, § 130.2, 130.4, 140.7 and 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §1 50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 13 0.0 c . §150.0(k)ll: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § 110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10 b through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §1 10.10(b)l: buildings with roof areas greater than 10,000 square feet For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 1 10 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum bulbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". -HV -AC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Nolte Residence Date 10/25/2015 System Name Living Zone Floor Area 2,979 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 3,726 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM 83,270 2,789 6,767 0 4,807 0 0 0 0 0 1 4,8071 92,884 2,789 PEAK Heating System Sensible Output per System 36,000 84,731 Total Output Btuh 36,000 Output Btuhls 12.1 4,164 Cooling System 0 Output per System 36,000 0 Total Output Btuh 36,000 0 Total Output Tons 3.0 4,164 Total Output Btuhls 12.1 Total Output (sqftff on 993.0 93,059 Air System CFM per System 2,210 HVAC EQUIPMENT SELECTION Airflow dm 2,210 Existing 20,783 13,953 36,000 Airflow cfm/s 0.74 Airflow dmlTon 736.7 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 20,783 13,953 36,000 Aug 3 PM Jan 1 AM Outside Air dmfs 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 OF 84 OF 84 OF t • ►a Heating Coil Supply Fan 2,210 cfm ' 82 F ROW 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air Ar 0 cfm 60 t 70 OF 80170 OF 55162 OF 55162 °F Cooling Coil Supply Fan 57 / 62 OF 2,210 cfm p� 65.2% I ROOM 78 % 69 OF EnergyPro 6.7 by EnergySoft User Number.- 2655 RunCode: 2015-10-25T17:22:46 /D: Page 17 of 17