Application Description: LANGNER / REPLACE LIGHTING / PLUMBING / RAISE CEILING
Property Zoning:
Application Valuation: $10,000.00
Applicant: a
LANGNER L&M LIVING TRUST
78100 MAIN ST #205
LA QUINTA, CA 92253 DEC 2 8 2015
CITY OF LP. QUIPITA
GOWWNITY DEyELOPMENT DEPARTB1ENT
LICENSED CONTRACTOR'S DECLARATION . .
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: _ License No.::CONV:140528101254097362
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, after, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($50
j=-1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is hot intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property'who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
TA_ 0, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
am exempt under Sec. . B.&P.C. for this reason
Date: J_Uzt(l /S Owner: L
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a.construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. Q.
Lender's
Lender's Address:
11111111111111111111
06
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/28/2015
Owner:
LANGNER L&M LIVING TRUST
Contractor:
LANGNER L&M LIVING TRUST
78100 MAIN ST #205
LA QUINTA, CA 92253
(760)831-7669
Llc. No.::CONV:140528101254097362
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and.will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:
Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county. ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes. _
Date: I L12811S Signature (Applicant or Agent)
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY . AMOUNT
PAID. PAID DATE
BSAS SB1473 FEE
101-0000-20306
0 $1.00
$1.00 12/28/15
PAID BY
METHOD
RECEIPT #
CHECK # CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32 SGU
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$24.66
$24.66
12/28/15
PAID BY
METHOD
•RECEIPT #
CHECK # '
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$5.08
$5.08
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
.101-0000-42403
0
$290.06
$290.06
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
DESCRIPTION
ACCOUNT
QTY'
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$47.86
12/28/15
PAID BY
METHOD
RECEIPT#
-,CHECK #
CLTD BY
LAWRENCE P LANGNER.
CHECK .
R11786
1076.32
SGU
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $367.66 $367.66
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$169.26
$169.26
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
DESCRIPTION
ACCOUNT
;QTY'
. AMOUNT
PAID
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$84.63
$84.63
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK # . `
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.31
SGU
DESCRIPTION
ACCOUNT,,
QTY .
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$24.18
$24.18
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID.
PAID DATE
WATER SYSTEM INST(ALT/REP PC
101-0000-42600
0
$12.09
$12.09
12/28%15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
Total Paid for PLUMBING FEES: $290.16 $290.16
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$130.50
$130.50
12/28/15
PAID BY'
}+'kuiy,..x:s
METHOD
..z
>'�,7,
i .=�,
xECEIPT�#
S-y'�„7.t
:x HECK -44,
CLTD BY
F
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
h Y .. is .i`"!"'
` F DESCRIPTIONc
P;:L�ii 'x.'oi+".�=.v�'"'f. i-.i�
)s*• H - - ",a£'!`a�c^i✓
PAIDDATE
_ .. .rY.3000NT7
X3,>aQTYAIVIOUNT$�iPAID
..,. A.:
.z
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$52.20
$52:20
12/28/15
5r+' x 2i' §�4a
PAID BY.<f<,;_�
gy
.U`4 G 3q,
y y..
'1°` S• ...'nr,�r..rae Y,pu' i"
CHECK #
CLTD BY ;
:.:METHOD.. r>4RECEIPT#13$F
_
LAWRENCE P LANGNER
CHECK
R11786
1076.32'
SGU
DESCRIPTION Y rnACCOUNT{"
shQTY
AINIOUNT`x
'PAID } _Y
`PAID DATE<'
zi
r ;'ss°.:ETeh@1v.&RIV,
"�.5w"a;'H.n
'"k'fE,a�:f;rid:4drLM .Ticeo:'4 j tG
t AD
i �Ut°ah:'.�':nrmf' �S::�i�`r'
Fkh Yvsi''r{in ,. M.;_iy9'E
"REMODEL,.FIRST 100 SF
101-0000-42400
0 :
$98.62
$98.62
12/28/15
'R - ". d Y - ,t;" _'v.'• a} ^:^' { y
1x x2 s1
PAIDgBY
'.- `; y:.5 .,,� ,2 d,.:�9` ".. arat4' .
"' n
. # ?" zS" 'S,.:.`£F'tia q°.g' amr's S
#,
" .C3' •5E 4- a..!{ _
f
CHECK #
r{ .xri. ,1.
u
a 4.ff .?gMETHO�D
A —Mti..
ffiRECEIRT
"
CLTD BY
LAWRENCE P LANGNER
CHECK
R11786
1076.32
SGU
S - q : '4''>^'h
?"y t
DESCRIP,TIONZM
" { iegm - i' 4.KY. `q1 ...." �.H .
Sa°s Sr
ACCOUNT`"vg
L 'fR'M
xi'
`�QTYAMOUNTk
.. ; �,.
P�. MA'' 4 ,2 fst
ZZ
I:rc �t' gsNS '3T'r i eLv,
PAID F'
...
YE i fir+,
P141D?DATE
_ .".....>,.. .F.,.;. 14-.1X3..yNS>':E`
r
,.... ,ja ..!.::-at
',:.-r�`u=.
1�.x .(i 'L`.',
._ui.�'.,,,,
r>
REMODEL,: FIRST 500 SF PC
101-0000-42600
0 <
.. $134.88
.:$134.88
12/28/15
Yq,
-�,SZKiztY-,a ::r: t �,;t:r`"
#h>£
'',c�' x a s.xags x.. -"-.z
K
CHEC #
cr ;r..+ A. 3"t
CLTD BYE
FgFMETIi00� , .4E,pRECEIPT
,ayi..m}i e..crv. w
y
r.Y 1�. v.c c8.o6.-.....
•c— Foca _.. . '.& ...+w..m
LAWRENCE•P LANGNER
..CHECK
R11786
1076:32. :
SGU
Total Paid for REMODEL: $416.20 $416.20
_µcry, _..
DESCRIPTION
Sa`�3� stY.xrsa'
T
"`
`ti.
�2`.y-r�'.".?"
,,..'4y"G.�;irKS.
f
E t
h S� M...=: .. G.::.3e..
CO s
..Ymi`.ia'.. t is S-4 eSk.mi,ixr Y.X...Yo>l
QTYy,
AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$1.30
$1.30
12/28/15
xF PAID`BY3 ; s - ; r
hxs-ejMETIiODt!t
;ARE
E' T �4
`fit
1>.
§
t:r:. `s ..3 P--.. ;-R ePY;:
s' .h, .1Y,E
C IP #
`VM- .��'"F: 7FF4'...
S CHECK #
CLTD BY
LAWRENCE P'LANGNER
'CHECK
1111786.
1076.32 '
SGU
..Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1:30• . " $1:30
• .
Description: LANGNER / REPLACE LIGHTING / PLUMBING / RAISE CEILING
Type: BUILDING, RESIDENTIAL Subtype:. REMODEL Status: APPROVED
Applied: 10/30/2015 SGU
Approved: 12/28/2015 JJO
Parcel No: 646200015 Site Address: 78109 LAGO DR LA QUINTA,CA 92253
Subdivision: TR 4295 & INT IN COMMON AREA Block: Lot: 15
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $10,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
ACTION DATE COMPLETION DATE
Details: REMODEL MASTER B/R, KIT& BR #1 BATH. REPLACE CAB. AND COUNTER TOPS IN MASTER B/R AND KIT. REPLACE SHOWER IN B/R
#1. NO LIGHTING WILL BE REPLACED PER PLANS. NEW APPLIANCES WILL BE INSTALLED. CEILING IN KIT WILL BE RAISED. ALL
CONSTRUCTION WILL BE PER 2013 ERC CODES. CODE CASE WILL DOUBLE FEE
Printed: Monday, December 28, 2015 10:14:49 AM 1 of 4 CREAJF
SYSTrMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE COMPLETION DATE
NOTES
NOTE
STEPHANIE GUMPERT
12/21/2015
12/21/2015
HOMEOWNERS ASSOCIATION LETTER RECEIVED TODAY 12-21
-15.
PLAN CHECK PICKED UP
STEPHANIE GUMPERT
12/3/2015
12/3/2015
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
11/17/2015
11/17/2015
PLAN CHECK SUBMITTAL
STEPHANIE GUMPERT
10/30/2015
10/30/2015
RECEIVED
RESUBMITTAL
STEPHANIE GUMPERT
12/2/2015
• 12/2/2015
ROBERT RICCIARDI DROPPED OF THE PLANS AND
RESUBMITTAL IS WAITING FOR JIM JOHNSON'S APPROVAL.
RESUBMITTAL
STEPHANIE GUMPERT
12/17/2015
12/17/2015
TELEPHONE CALL
JIM JOHNSON
11/17/2015
11/17/2015
CALLED LARRY LANGNER TO INFORM HIM THE PLANS ARE
READY FOR CORRECTIONS
TELEPHONE CALL
JIM JOHNSON
12/28/2015
12/28/2015
CALLED ROBERT RICCIARDI TO INFORM HIM PLANS ARE READ
TO ISSUE
Printed: Monday, December 28, 2015 10:14:49 AM 1 of 4 CREAJF
SYSTrMS
Printed: Monday, December 28, 2015 10:14:49 AM 2 of 4
SYSTEMS
CONDITIONS
INFORMATION
CONDITION
TYPE
CONTACT DATE DATE DATE
ADDED REQUIRED SATISFIED
STATUS
PAID -
REMARKS
NOTES
READY TO ISSUE
CHECKLIST
STEPHANIE 12/21/2015
GUMPERT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
COMPLETE
12/28/15 R11786 1076.32 CHECK LAWRENCE P SGU
LANGNER
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00
BSA:
CONTACTS
101-0000-42403
0
$24.66
NAME TYPE
NAME
ADDRESSI•
CITY
STATE
ZIP
PHONE FAX EMAIL
APPLICANT
LANGNER L&M LIVING TRUST
78100 MAIN ST #205
LA QUINTA
CA
92253
(760)831-7669
CONTRACTOR
LANGNER L&M LIVING -TRUST
78100 MAIN ST #205
LA QUINTA
CA
92253
(760)831-7669
OWNER
LANGNER L&M LIVING TRUST
78100 MAIN ST #205
LA QUINTA
CA
92253
(760)831-7669
Printed: Monday, December 28, 2015 10:14:49 AM 2 of 4
SYSTEMS
FINANCIAL
INFORMATION
CLTD
DESCRIPTION ACCOUNT QTY AMOUNT
PAID -
PAID DATE RECEIPT # CHECK # METHOD PAID BY
BY
BSAS SB1473 FEE 101-0000-20306 0 $1.00
$1.00
12/28/15 R11786 1076.32 CHECK LAWRENCE P SGU
LANGNER
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00
BSA:
RESIDENTIAL, EA
101-0000-42403
0
$24.66
$24.66
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
ADDITION 1,000SF
LANGNER
RESIDENTIAL,
101-0000-42600
0
$5.08
$5.08
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
ADDITION 1,000SF, PC
LANGNER
RESIDENTIAL, FIRST
101-0000-42403
0
$290.06
$290.06
12/28/15
'R11786
1076.32
CHECK
LAWRENCE P
SGU
1,000SF
LANGNER
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
1,000SF, PC
LANGNER
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $367.66 $367.66
FIXTURE/TRAP
101-0000-42401
0
$169.26
$169.26
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
LANGNER
FIXTURE/TRAP PC
101-0000-42600
0
$84.63
$84.63
12/28/15
R11786.
1076.32
CHECK
LAWRENCE P
SGU
LANGNER
Printed: Monday, December 28, 2015 10:14:49 AM 2 of 4
SYSTEMS
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
10/30/2015
11/16/2015
11/17/2015
REVISIONS REQUIRED
2ND BLDG NS (1
WK)
JIM JOHNSON
12/2/2015
12/9/2015
12/3/2015
BY
WATER SYSTEMLAWRENCE
101-0000-42401
.0
$24.18
$24.18
12/28/15
R11786
1076.32
CHECK
P
SGU
INST/ALT/REP
LANGNER
WATER SYSTEM
101-0000-42600
0
$12.09
$12.09
12/28/15.
R11786
1076.32
CHECK
LAWRENCE P
SGU
INST/ALT/REP PC
LANGNER
Total Paid for PLUMBING FEES: $290.16. $290.16
REMODEL, EALAWRENCE
101-0000-42400
0
$130.50
$130.50
12/28/15
R11786
1076.32
CHECK
P
SGU
ADDITIONAL 500 SF
LANGNER
REMODEL,
101-0000-42600
0
$52.20
$52.20
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
ADDITIONAL 5000 SF PC
LANGNER
REMODEL, FIRST 100 SF
101-0000-42400
0
$98.62
$98.62
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
LANGNER
REMODEL, FIRST 500 SF
101-0000-426000
$134.88
$134.88
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
PC'
LANGNER
Total Paid for REMODEL: $416.20 $416.20
SMI - RESIDENTIAL
101-0000-20308
0
$1.30
$1.30
12/28/15
R11786
1076.32
CHECK
LAWRENCE P
SGU
LANGNER
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.30 $1.30
TOTALS:. .32
INSPECTIONS
PARENT PROJECTS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
REVIEWS
STATUS REMARKS
NOTES
IST BLDG NS (2 WK)
JIM JOHNSON
10/30/2015
11/16/2015
11/17/2015
REVISIONS REQUIRED
2ND BLDG NS (1
WK)
JIM JOHNSON
12/2/2015
12/9/2015
12/3/2015
REVISIONS REQUIRED
3RD BLDG NS (1 WK)
JIM JOHNSON
1 12/17/2015
12/28/2015,
12/28/2015
1 APPROVED
Printed: Monday, December 28, 2015 10:14:49 AM 3 of 4
SYSTEMS
BOND INFORMATION
Printed: Monday, December 28, 2015 10:14:49 AM 4 of 4'
SYSTEMS
I
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
11/17/2015
JIM JOHNSON
78-109 LAGO DR..docx 78-109 LAGO DR..docx
-0
DOC
12/21/2015
STEPHANIE GUMPERT
HOMEOWNERS HOMEOWNERS
ASSOCIATION ASSOCIATION
LETTER.pdf LETTER.pdf
0
Printed: Monday, December 28, 2015 10:14:49 AM 4 of 4'
SYSTEMS
I
Bin #
5�
Qty of La Q uin to
Buifding 8£ Safety Division
. _ 78-495 Calle Tampico
C-),+9 La Quinta, CA 92253 - (760) 777-7012
I Building Permit Application and Tracking Sheet
Permit #
Project Address: I6
Owner's Name: 141
A. P. Number: aw _D� S
Address:
Legal Description: r;?
City, ST, Zip:
Contractor: C
Teleh ne:
Po
Address:
Project Description:
City, ST, Zip:
AM 00 ,6- A)
Telephone:
State Lic. # :
City Lic. #:
o i
Arch., Cngr., Designer: oJC'K/
L7 /
Address:
City, ST, Zip:
Telephone:
ConstructiontructionTY c cu. PancY•
Type: O
State Lic. #
Repair Demo
tt3Pec (circle on New Add'n Altete
Project
Name of Contact Person: 1R
Sq. Ft.: 3
#Stories: (
# Units: P
Telephone # of Contact Person: ID (.16
Estimated Value of Project: 3 C> -z)
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan. Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2nd Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN IiOUSE:-
'"! Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. \Vks. Appr
Date of permit issue
School Fees,
Total Ycrmit Fees
ITEM #0599032, 0623866
UTI LITEC.. LED RECESSED
RETROFIT DOWNLIGHT
Utilitech & UT Design® is a registered
trademark of lLF, LLC. All Rights Reserved. MODEL #MQ TI-1017-ILED1 1.5K827
MQTL1017-LED1 1.51<850
e.
ATTACH YOUR RECEIPT HERE
Serial Number Purchase Date
0 O Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-866-994-4148, 8 a.m. - 6 p.m., EST, Monday - Thursday,
8 a.m. - 5 p.m., EST, Friday.
AB15205 UT1UTECI
Lowes.corn W FRIMC111
1
CIT ,QF LA QUINTA
_BU1L71Nta'M-17
VED
MU
DATE__By ------
HALO LED ICAT HOUSING for NEW CONSTRUCTION
The H7501CAT is a dedicated LED new construction housing to
be used with designated HALO LED modules.The H7501CAT is
designed for insulated ceilings and can be in direct contact with
ceiling insulation*. This AIRTITE housing design prevents airflow
between conditioned and unconditioned spaces and saves on both
heating and air conditioning costs. The LED connector system
provides high efficacy code compliance when used with designated
HALO LED modules and trims.
DESIGN FEATURES
Housings
Aluminum construction for
greater heat dissipation. H750
ICAT housing is gasketed to
prevent airflow from heated or
air conditioned spaces.
Plaster Frame
Galvanized steel frame. Housing
adjust§ -in plaster frame to
accommodate up to 1" ceiling
thickness. Regressed locking
screw for securing hanger bars.
Cutouts included for easily
crimping hanger bars in
position
Slide -N -Sider Junction Box
• Positioned to accommodate
straight conduit runs.
• Seven 1/2" trade size conduit
knockouts with true pry -out
slots.
• Slide -N -Side wire traps allow
non metallic sheathed cable to
be installed without tools and
without removing knockouts.
• Allows wiring connections to
be made outside the box.
• Simply insert the cable directly
into the trap after connections
are made.
• Accommodates the following
standard non-metallic
sheathed cable type:
• U.S. #14/2, #14/3, #12/2, #12/3
• Canada: #14/2, #14/3, #12/2
GOT NAIL! Pass-N-Thrul
Bar Hangers
Bar Hanger features include
• Pre-installed nail easily installs
in regular lumber, engineered
lumber and laminated beams.
• Safety and Guidance system
prevents snagging, ensures
smooth, straight nail
penetration and allows bar
hangers to be easily removed
if necessary
• Automatic leveling flange
aligns the housing and allows
holding the housing in place
with one hand while driving
nails.
• Housing can be positioned at
any point within 24" joist
spans
• Score lines allow tool -free
shortening for 12" joists and
bar hangers do not need to be
removed for shortening.
• Bar hangers may be
repositioned 90• on plaster
frame
• Integral T -bar clip snaps onto
T -bars — no additional clips are
required.
7"
1176rnml
o' a*6
L 6-112" J 1/2'.
1165mml 113mml
TOP VIEW
O7.318"
1187mm1
1267mm1
Cooper Lighting
by FA -N
LED Module Connection
Halo LED modules simply install
with a plug-in 120V -277V rated
line voltage wiring connector
(UL and CSA Listed Luminaire
Disconnect). This non -screw -base
connection preserves the high
efficacy rating and prevents use of
low efficacy incandescent sources
(see LED Module specifications).
Caution
Connection is rated for 120V and
277V input. Installer must verify
LED module voltage is compatible
with the applicable voltage input.
If uncertain, consult a qualified
electrician.
Labels
• UL/cUL Listed 1598 Luminaire
• CE Marking - "Conformite
Europeene" conformity with
the Council of European
Communities Directives,
meeting internationally
recognized compliance when
used with ML56 Series LED
modules
• UL/cUL Listed for Feed Through
• UL/cUL Listed for Damp Location
• UL/cUL Listed for Wet Location
with select trims
• UL/cUL Listed for direct contact
with insulation and combustible
material*
• Rated for 20W maximum
Qualification
May be used with qualified Halo
LED modules and designated
trims for High Efficacy Luminaire
Compliance:
• State of California Title 24
• International Energy
Conservation Code 0ECC)
• Washington State Energy Code
• New York State Energy
Conservation Construction Code
EIS®ro
unCompliant
RECconstructio a" MWY ® F
DEC 17 2015 BUILDING
CITY OF LA ®UINAPPTA FOR CO
COM! -AI MITY MVEL.OPMEN
DATE
* Not to be used in direct contact with spray foam insulation.
HALO®
H7501CAT
6" New Construction
IC AIR-TITEI Housing
For
Halo LED Modules and
Trims
ML56 Series
RL56 Series
RA56 Series
High Efficacy LED Housing
FOR USE IN
INSULATED CEILINGS
FOR DIRECT CONTACT
WITH INSULATION*
•
at1A
if mpliant w h
e t er to ENE GY
' 1 MY
roducts
List an) Applia ce
Databags.
BY
141509
6117/2014
C E
ENERGY
STAR®
mage
�mo�b
ECC
µua.w
if mpliant w h
e t er to ENE GY
' 1 MY
roducts
List an) Applia ce
Databags.
BY
141509
6117/2014
ORDERING INFORMATION - RL56 SERIES
SAMPLE NUMBER: H7501CAT - RL560WH6927
Order housing, light module, trim and separately.
H7501CAT= 6" Aperture, New Construction, IC AIR-TITET"', High Efficacy LED Housing
I"
ORDERING INFORMATION - RA56 SERIES
SAMPLE NUMBER: H7501CAT - RA5606927WH
Order housing. light module, trim and separately.
H7501CAT= 6" Aperture, New Construction, IC AIR-TITET', High Efficacy LED Housing
80 CRI
RL560WH6827= 5"/6" Retrofit Baffle - Trim LED Module, 80CRI, 2700K. Matte White
RL560SN6827= 5"/6" Retrofit Baffle - Trim LED Module, 80CRI, 2700K. Satin Nickel
RL560WH6830= 5"/6" Retrofit Baffle - Trim LED Module, 80CRI, 3000K, Mahe White
RL560SN6830= 5"/6" Retrofit Baffle - Trim LED Module. 80CRI, 3000K, Satin Nickel
RL560WH6835= 5"/6" Retrofit Baffle - Trim LED Module, 80CRI, 3500K, Matte White
90 CRI
RLS60WH6927= 5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 2700K, Matte White
RL560SN6927= 5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 2700K, Satin Nickel
RL560WH6930= 5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 3000K, Matte White
RL560SN6930= 5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 3000K, Satin Nickel
RL560WH6935= 5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 3500K, Matte White
Very Wide Flood - VWFL Models
RA5606927WH= 5"/6" LED Adjustable Gimbal, 90CRI, 2700K, White, Very Wide Flood
RA5606930WH= 5"/6" LED Adjustable Gimbal, 90CRI, 3000K, White, Very Wide Flood
Narrow Flood - NFL Models
RA5606927NFLWH= 5"/6" LED Adjustable Gimbal, 90CRI, 2700K, White, Narrow Flood
RA5606930NFLWH= 5"/6" LED Adjustable Gimbal, 90CRI, 3000K, White, Narrow Flood
ORDERING INFORMATION - ML56 SERIES
SAMPLE NUMBER: H7501CAT - ML5606830 - 693WB
Order housing, light module, trim and separately. ,
H7501CAT= 6" Aperture, New
Construction, IC
AIR-TITET"', High
Efficacy LED
Housing
f`
600 Series / 80 CRI
ML5606827= 5"/6" LED Retrofit Downlight Light Module. 600
lumen, 80CRI, 2700K
ML5606830= 5"/6' LED Retrofit Downlight Light Module, 600
lumen, 80CRI, 3000K
ML5606835= 5"/6" LED Retrofit Downlight Light Module, 600
lumen, 80CRI, 3500K
ML5606840= 5"/6' LED Retrofit Downlight Light Module. 600
lumen, 80CRI, 4000K
600 Series / 90 CRI
ML5606927= 5"/6" LED Retrofit Downlight Light Module, 600
lumen, 90CRI, 2700K
ML5606930= 5"/6" LED Retrofit Downlight Light Module, 600
lumen, 90CRI, 3000K
ML5606935= 5"/6" LED Retrofit Downlight Light Module. 600
lumen, 90CRI. 3500K
MLS606940= 5"/67' LED Retrofit Downlight Light Module, 600
lumen, 90CRI, 4000K
900 Series / 80 CRI
ML5609827= 5"/6" LED Retrofit Downlight Light Module, 900
lumen, 80CRI. 2700K
ML5609830= 5"/6" LED Retrofit Downfight Light Module. 900
lumen. 80CR1, 3000K
ML5609835= 5"/6" LED Retrofit Downlight Light Module, 900
lumen. 80CRI, 3500K
ML5609840= 5"/6" LED Retrofit Downlight Light Module, 900
lumen, 80CRI, 4000K
900 Series / 90 CRI
ML5609927= 576" LED Retrofit Downlight Light Module. 900
lumen. 90CRI, 2700K
ML5609930= 5"/6" LED Retrofit Downlight Light Module, 900
lumen, 90CRI, 3000K
ML5609935= 5"/6" LED Retrofit Downlight Light Module, 900
lumen, 90CRI, 3500K
ML5609940= 5"/6" LED Retrofit Downfight Light Module. 900
lumen, 90CRI. 4000K
1200 Series / 80 CRI
ML5612827= 5"/6" LED Light Module, 1200 lumen, BOCRI, 2700K
ML5612830= 5"/6" LED Light Module, 1200 lumen, 80CRI, 3000K
ML5612835= 5"/6" LED Light Module, 1200 lumen, 80CRI, 3500K
ML5612840= 5"/6" LED Light Module, 1200 lumen, 80CRI, 4000K
1200 Series / 90 CRI
ML5612927= 5"/6" LED Light Module, 1200 lumen, 90CRI, 2700K
ML5612930= 5"/6" LED Light Module, 1200 lumen, 90CRI, 3000K
ML5612935= 5"/6" LED Light Module, 1200 lumen, 90CRI, 3500K
ML5612940= 5"/6" LED Light Module, 1200 lumen, 90CRI, 4000K
690 Series - 6" LED Trims
Non -Conductive "Dead Front" Baffles
691 WB=6" LED Trim. Polymer "Dead -Front",
Shallow White Baffle & Flange (For
use with 600 Series LED Light
Modules only)
Reflectors
692SC=6" LED Downlight Trim, Specular
Reflector & White Flange
692H=6" LED Downlight Trim, Haze
Reflector & White Flange
692W=6" LED Downlight Trim, White
Reflector & Flange
Baffles
693WB=6" LED Downlight Trim, White
Micro -Step Baffle & Flange
693BB=6" LED Downlight Trim, Black
Micro -Step Baffle & Flange
693SNB=6" LED Downlight Trim, Satin
Nickel Micro -Step Baffle & Flange
693TBZB=6" LED Downlight Trim, Tuscan
Bronze Micro -Step Baffle & Flange
Semi -Regressed Eyeballs
694WB=6" LED Directional Trim, White
Eyeball, Baffle & Flange
694SNB=6" LED Directional Trim, Satin
Nickel Eyeball, Baffle & Flange
694TBZB=6' LED Directional Trim, Tuscan
Bronze Eyeball, Baffle & Flange
Wall Wash
695WW=6" LED Downlight Trim, Wall Wash
with Specular Kick Reflector &
While Flange
Shallow Baffle
696WB=6" LED Trim, White Shallo Ba
& Flange p
H7501CAT
ML56CLIP= 6" Friction Clip Kit - For use with
non -torsion spring housings. 6"
clips included.
W W6955C= Wall Wash Insert - Specular Kick
Reflector for 695WW (1 included
with trim). For double wall washing
or replacement.
TRM690WH=6" LED Oversize Trim Ring for use
with 59- series trims, White 6.9"
I.D., 9.5" O.D.
Ring slips over LED trim. Inset
design allows 6" trim to fit into
oversize ring for an even trim
surface
EBA560PK= Replacement screwbase adapter
to LED disconnect with cap
ML56-1200 Series Beam Forming Optic Media
BFR56NFL_-Beam forming reflector kit, narrow
flood, 25" nominal
BFR56MH=Media holder, accepts one 3.45"
lens. Requires BFR56NFL & L345SF,
order separately.
L345SF=3.45" diameter soft focus lens.
Requires BFR56NFL and BFR56MH,
order separately.
OF LA QUINT,
ILDING & SAFETY DEI
APPROVED
=OR CONSTRUCTION
Eaton Eaton's Cooper Lighting Business O 2014 Eaton
1000 Eaton Boulevard 1121 Highway 74 South All Rights Reserved
Cooper Lighting Cleveland. OH 44122 Peachtree City. GA 30269 Printed in USA Scecnficationsand
United Stares P 770-486-4800 Publication No. ADV141509 - dimensions subject to
by E:T-N Eaton.com, wvnv cooperlighting cpm June 2014 change without notice.
BY
Tit(f auk&
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a build' ermit has been submitted in your name listing yourself as the builder of the property
improvements specified at . �/U 1 � 2) /L
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signs you understand or verify this information.
understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
tuilLglpermit that erroneously implies that the property owner is providing his or her own labor and material personally. 1, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while. working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
42. I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
54 I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
�4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
pe is and contracts.
5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
Rb�i6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and.contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
risk.
-4-4. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with the intent 'to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
--46-41 understand as an Owner -Builder if I sell the property for which this pernut is issued, I may be held liable for any
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
I understand I may obtain more information regarding my obligations as an. "'employer" from the Internal Revenue
Service, the United States Small -Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party legally: and financially responsible for proposed construction activity at the following address:
I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner -Builders as.well as employers.
,�OA-2I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and. wish to hire Contractors,
you will be responsible for verifying whether or. not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature.
Signature of property owner Date:
Note: The following Authorization Form is required lobe completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the. Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of,which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign; and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its'accuracy. Note: A copy of the owner's driver's license, form notarization, or other ver f cation
acceptable to the agency is required to be presented when the permit is issued to verify the property owners signature.
Property Owner's Signature: Date:.
a RQr.:Ivan- Dapay
O.........._ propeq management
LAGO LA QUINTA HOMEOWNERS ASSOCIATION
December 18, 2015
Larry Langer
78109 Lago Drive
La Quinta, CA 92253
Regarding: 78109 Lago Drive, Architectural Request Approval
Dear Larry Langer,
The Architectural Committee at Lago La Quinta has approved your ARC request to
upgrade the interior of your home.
Please advise your contractor that the common areas, including the streets are not to be
used for storage of materials or equipment at any time during construction. Any materials
delivered should be unloaded onto your property, not the street.
If there is any debris from construction in the street, the contractor must sweep the street
prior to washing the affected area each day. The contractor may not post signage at the
property. Any damage done to the common area is your responsibility to repair.
Please inform your contractor that he must also follow all rules and regulations of the
community. Lago La Quinta permits construction from 7 am to 6 pm, Monday through
Saturday.
It is the homeowner's responsibility to ensure all permits required by the City of La Quinta
are obtained by you or your contractor.
Sincerely,
• Cl�z��ue.J�,rr�zal�u,�
Stephanie Swenstad
Avail Property Management
51350 Desert Club Dr. Suite 4, La Quinta, CA 92253
Tel: (760) 771-9546 Fax: (760) 771-1655
service@availhoa.com
TAf44Qubira
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
DATE: 12/3/2015
STATUS: 2ND. REVIEW
PLAN CHECKED BY: JIM JOHNSON .
TELEPHONE NUMBER: (760) 777-7130
ADDRESS: 78-109 LAGO DR.
DESCRIPTION: CODE CASE, REMODEL
APPLICANT: LANGER / HOWARD
PLAN CHECK #: BRES2015-0419
This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the
correction: following items are included:
2 SETS OF PLANS REDLINED SET J
ASSESSORS SET 3 2 NEW REVISED SETS
THIS CORRECTION LIST WITH PHOTOS STRUCTURAL OBSERVATION LETTER
THIS CORRECTION LIST / RESPONSES
HOA LETTER
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents /
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List Pagel of4
SECTION A - GENERAL
I ) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code §5536. Resubmittals will not be accepted with signatures missing. REVI PLANS TO
SHOW FULL EXTENT OF WORK (SEE PHOTOS)-- �� W "° 1�'�
SECTION C - ARCHITECTURAL
1) Specify hearth material at all fireplaces. (CRC §R1001.9) A0V1,6 F"4'
2) Note on Plans: "Combustible materials shall not.be placed less than 6" from the fireplace opening." (CRC
§R1001.11, Exception 4)
4
3) Show dimensions for hearth extension at masonry fireplace. Hearths shall extend at least 16 inches from the
front of, and at least 8 inches beyond each side.of, the fireplace opening. Where the fireplace opening is 6
square feet or larger, the hearth extension shall extend at least 20 inches in font of, and at least 12 inches
b�eyyond each side of, the fireplace opening. (CBC §R1001.10) elt,4Zr b 14 C �G��1"e
'F'# 1; t•� ��! G£ .�Y..t1 G °Ti L� �'r I N ru -nif, ;:w -e, ?w -ca
SECTION E — ELECTRICAL
J
1) Provide at least 50 percent of the total wattage installed for kitchen illumination from high -efficacy
luminaires. A kitchen lighting worksheet shall be provided on plan detailing proposed fixture wattage, lamp
type and efficacy rating that clearly identifies compliance with California Energy Code§ 150(k)8.
451 -"roe .
2) Note on Plans: "Luminaires (light fixtures) in tub or shower enclosures shall be labeled `suitable for damp
location'." (CEC §410.4(A)) I
SECTION G — ENERGY EFFICIENCY &f i1 KVX- (41 I> Q. $.e T,� t 6V -4a
-TV.A8 " 441 6>14 trIGI a, '"o, '
1) [Princip for alterations] Provt a complete Energy Calculations showing compliance with the 2008
California Energy Code for this project. The CF -IR -ALT form shall be used to document the minimum
energy requirements needed for alterations to an existing dwelling. Please note that once further information
is provided a Performance Compliance method may be required to show compliance.
2) Show all required energy efficient (High -efficacy) lighting on Electrical plan. Providethe.wattage.of
luminaires on plan or in a legend that corresponds with the proposed switching,requirements.demonstrating
compliance with the California Energy Code, Section 150(k) 1 — 14. A clear description/details of the high
efficacy (fluorescent) and alternate lighting (incandescent; etc`)Tis-required:'FOR ALL NEW LIGHTING
INSTALLED-. ( t - S �'�r g \41 V Ic a 4
Informational Items:
a) High Efficacy Luminaires. High Efficacy Luminaires for residential lighting shall contain only high
efficacy lamps and shall not contain a medium screw base sock`et'(E24%E26). A high efficacy lamp has a
lamp efficacy that is no lower than the effic`aciescontained`in`TABL;E-i-50=C. jvp 4p pits wao4T
O HAW ca -e Vel d;Noa S-oGPa' o 0466 070416 U'S 00$9.4
b-)aKitchen. At least;50 percent of the otal wattage must be from high -efficacy luminaires. Adjacent areas
(noo'� k, butler's pantry, etc:)" are considered as kitchen if the lighting for the adjacent areas is on the same
switch as the lighting for the kitchen. For incandescent luminaires, the wattage usedin calculations 's t,t�e
highest relamping rated wattage of the fixture. P_V,-WIKSt19 16 tat. r, I�G��'�
A►Iq H r4W • V;Vt cp4� CVMl J k19La , .
Residential Plan Check Correction List
Page 2 of 4
r�
City of La Quinta
c) Bathrooms, toilet rooms, garages, laundry rooms and utility rooms. Permanently installed luminaries
that are rot high efficacy are allowed provided they are controlled byf a —m-a-67—dal-on occupant sensor(s_)..7 -
(Cal iforNa Energy Code § 150(k) 3) (',�, (l 416H
d) Living Room, dining room, bedrooms, hallways, etc. (spaces other than kitchens, bathrooms,
garages, laundry rooms and utility rooms) Permanently instal led=luminaries:that are not high effic
are allowed provided they are controlled by a dimmer switch or manual -on occupant sensor(§). Close
less than 70 square feet in area may have low=efficacy (incandescent) luminaries. (California Ener y
Code § 150(k) 4) 'go Of V-VCAZJ
e) Luminaires that are recessed'into insulated ceilings are requiredtoiSe IC & AT rated (insulation contact
and airtight wiih air leakage less than 2.0 CFM at 75 pascals when tested in accordance with ASTM
E283), and be sealed with a gasket or caulk between the luminaire housing and ceiling, and shall have all
air leak paths between conditioned and unconditioned spaces sealed'with a gasket or caulk.
-t4>~ NAe* . fke C e44 9!V 4 t6-f*TA-0 MC-Etr,i 11�t01 F�v iT2S M0LLV-101Jr#
SECTION I - STRUCTURAL
1) STRUCTURAL OBSERVATION LETTER REQUIRED
Important note to Engineer of Record:
If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply
submit o gopies
of a few � � �uJbt�J,�i calculations. to I 46P
For resubmittal, include:
• One complete set of structural calculations from the previous submittal, and...
• Two complete, stamped and wet -signed sets of structural calculations for review and approval. Y ur written
responses should direct the plan reviewer to the appropriate revised page(s).
Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets,
loose pages will not be assembled by the Building Department.
Important note: If manufactured truss products are used on this project, be aware that the City of La Quinta does
not allow deferred submittals. Truss calculations are required no later than the second submittal.
SECTION K - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required
for resubmittal, this administrative item must be addressed prior to issuance of building permit.
3) Provide letter ofapproval from Homeowners' Association.-
4) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation
will be performed when Plans are complete. ESTIMATED VALUATION SHALL BE REVISED TO SHOW
FULL EXTENT OF WORK.
END CORRECTION LIST
Residential Plan Check Correction List Page 3 of 4
M
City of La Quinta
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List
Page 4 of 4
SIMONE
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
DATE: 11/17/2015
STATUS: FIRST REVIEW
PLAN CHECKED BY: JIM JOHNSON
TELEPHONE NUMBER: (760) 777-7130
ADDRESS: 78-109 LAGO DR.
DESCRIPTION: REMODEL
APPLICANT: LANGNER/HOWARD
PLAN CHECK #: BRES2015-0419
This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the
correction: following items are included:
3 SETS OF PLANS .
THIS CORRECTION LIST
REDLINED PLANS
2 NEW REVISED SETS _
THIS CORRECTION LIST / RESPONSES
otir
.r( n 9. 2015
CI
OF LA QUIT%
COMMUPIT1I DD VEtAPMv4T
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and,all documents listed above with your resubmittal.
Residential Plan Check Correction List Page 1 of 4
11
SECTION A - GENERAL
Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code §5536. Resubmittals will not be accepted with signatures missing. BY PERSON WHO
DREW THE PLANS
,�2) Note on Plans: "All construction shall comply with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes and the La Quinta Municipal Code." Remove notes referencing
other Codes.
�Note on Plans: "All `or equal' substitutions must be submitted to, and approved by the Building Official prior
to installation of the item."
USC.
SECTION E — ELECTRICAL
1) Note on Plans: "Aluminum conductors are permitted only if size 1/0 or larger, and only to feed main or sub -
panels. All other current carrying conductors shall be copper." (LQMC §8.03.040)
./-'2) Note on Plans: "Provide at least two 20 -ampere small appliance branch circuits to serve all wall, floor, and
countertop receptacles in kitchen, pantry, breakfast room, dining room, or similar area. Such circuits shall
have no other outlets." (CEC §210.11(C)(1) and 210.52(B)(1) through 210.52(B)(3)) DOM -
3) Note on Plans: "Provide at least one 20 -ampere branch circuit to serve laundry appliances. Such circuit(s)
shall have no other outlets." (CEC'§210.11(C)(2); 210.52(F))
/4) Note on Plans: "Provide at least one 20 -ampere branch circuit to serve bathroom receptacles. Such circuit(s)
shall have no other outlets." (CEC §210.11(C)(3); 210.52(D))
Specify GFCI protection for receptacles in bathrooms. (CEC §210.8(A)(1)) V%NAk—
ify GFCI protection for receptacles serving the kitchen countertop. (CEC §210.8(A)(6)) Vq1Yj
7) 19itchep, pantries, breakfast rooms, dining rooms, and similar area receptacles shall comply with the
olIowing: (CEC §210.52(C)): NEW COUNTER AREA CREATED IN KITCHEN
a) Provide a receptacle outlet at each wall counter space 12 inches or wider.
b) Provide receptacle outlets at each wall counter so that no point along the wall line is more than 24 inches,
measured horizontally from a receptacle outlet in that space.
c) Provide at least one receptacle outlet at each island counter space with a long dimension of 24 inches or
greater and a short dimension of 12 inches or greater.
d) Provide at least one receptacle outlet at each peninsular counter space with a long dimension of 24" or
greater and a short dimension of 12" or greater. A peninsular countertop is measured from the connecting
edge.
"Ote on Plans: "Smoke alarms shall be 120 -volt with battery back-up." (CRC §R314.4)
F-VW Lei
9 Provide 120 -volt smoke alarm(s). (CRC §R314.4) Show all locations on Plans.
Informational Item: In dwelling units, single- or multiple station smoke alarms shall be installed and maintained
at all of the following locations:
Residential Plan Check Correction List Page 2 of 4
a
City of La Quinta
1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
2. In each room used for sleeping purposes.
3. In each story within a dwelling unit, including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door
between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower
vel provided that the lower level is less than one full story below the upper level. (CRC §R314.3)
1 Note on Plans: "Provide interconnection so that the activation of any smoke alarm will activate all smoke
alarms in the dwelling." (CRC §R314.5) , A-
11)ote on Plans: "Carbon monoxide alarms shall be 120 -volt with battery back-up." (CRC §R315.1.1)
QOY�i
12) Provide 120 -volt carbon monoxide alarm(s). (CRC §R315.1.1) Show all locations on Plans.
Informational Item: In dwelling units and in sleeping units within which fuel -burning appliances are installed
and in dwelling units that have attached garages an approved carbon monoxide alarm shall be installed at all of
the following locations:
1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
2. On every level of a dwelling unit including basements. (CRC §R315)
Note on Plans: "Provide interconnection, where more than one carbon monoxide alarms is required, so that
the act' ation of one alarm shall activate all of the alarms in the dwelling." (CRC §R315.1.2) �&
14 Sho
w the location of all existing and proposed smoke and carbon monoxide alarms. (CRC Chapter 1,
1,§106.1.1)
SECTION G — ENERGY EFFICIENCY
1) Show on plan or in a legend that corresponds with the proposed switching requirements demonstrating
compliance with the California Energy Code, Section 150(k) 1 — 14. A clear description/details of the high
efficacy (fluorescent) and alternate lighting (incandescent, etc.) is required. See electrical plan.
Informational Items:
a) High Efficacy Luminaires. High Efficacy Luminaires for residential lighting shall contain only high
efficacy lamps and shall not contain a medium screw base socket (E24/E26). A high efficacy lamp has a
lamp efficacy that is no lower than the efficacies contained in TABLE 150-C.
b) Bathrooms, toilet rooms, garages, laundry rooms and utility rooms. Permanently installed luminaries
that are not high efficacy are allowed provided they are controlled by a manual -on occupant sensor(s).
(California Energy Code §150(k) 3)
c) Living Room, dining room, bedrooms, hallways, etc. (spaces other than kitchens, bathrooms,
garages, laundry rooms and utility rooms) Permanently installed luminaries that are not high efficacy
are allowed provided they are controlled by a dimmer switch or manual -on occupant sensor(s). Closets
less than 70 square feet in area may have low -efficacy (incandescent) luminaries. (California Energy
Code § 150(k) 4)
d) Luminaires that are recessed into insulated ceilings are required to be IC & AT rated (insulation contact
and airtight with air leakage less than 2.0 CFM at 75 pascals when tested in accordance with ASTM
E283), and be sealed with a gasket or caulk between the luminaire housing and ceiling, and shall have all
Residential Plan Check Correction List Page 3 of 4
r
City of La Quinta
air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk.
SECTION H,CALGREEN
1) P�vide a table on the plans that contains the following requirements:
Alternatively, the applicant may provide calculations for proposed plumbing fixtures demonstrating
compliance with CALGreen §4.303.1, Item 2.
SECTION K - MISCE ANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required. ,
Residential Plan Check Correction List
Page 4 of 4
FIXTURE FLOW RATES
FIXTURE TYPE
MAXIMUM FLOW RATE
Showerheads
2 g m 80 psi
Lavatory faucets
1.5 gpm 60 psi
Kitchen faucets
1.8 g m @ 60 psi
Water closets
1.28gallons/flush
Urinals
0.5 gallons/flush
Alternatively, the applicant may provide calculations for proposed plumbing fixtures demonstrating
compliance with CALGreen §4.303.1, Item 2.
SECTION K - MISCE ANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required. ,
Residential Plan Check Correction List
Page 4 of 4