BSOL2016-0046aw.
78-495 CALLE TAMPICO 4
LA QUINTA, CALIFORNIA 92253
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
A
Application Number:
BSOL2016-0046
(J n
wner: �i''l
Property Address:
79190 LAURIE CT Crf
ROBER PATERS
APN:
604343006
�/
�`(lr
Property
Nf' uE p
)F L M�NrpE
Application Valuation:
$17,732.00
Applicant:
VIVINT SOLAR DEVELOPER LLC
3301 N THANKSGIVING WAY
STE 500
LEHI, UT 84043
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C46. C1l0 License No.: 997/3'7516 L C � r
Date: 10 Contractor: V I V (hl �lll V r�P—
OWNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees,.provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
Contractor:
i 111111 11111 ilii ilii
13
VOICE (760) 777-1125
FAX (760) 777=7011
INSPECTIONS (760) 777-7153
VIVINT SOLAR DEVELOPER LLC
3301 N THANKSGIVING WAY
STE 500
LEHI, UT 84043
(855)877-2974
Llc. No.: 973756
Date: 3/24/2016
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
L./ I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and polity number are:
Carrier: Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with tthose rovisions. /. (� I //npL G 1
Date: oL Applicant: v I U, t �.1(� 1Q✓ 1 /'Gi-t f
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or'pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -men con(e,/d property for inspection purposes.
Date: 3 �' r 6 Signature (Applicant or Agent): feLkA�
FINANCIAL •• •
DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE
BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 3/24/16
PAID BY METHOD RECEIPT # CHECK # CLTD BY
VIVINT SOLAR DEVELOPER LLC CHECK R14196 1790 MFA
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$24.17
3/24/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC
CHECK
R14196
1790
MFA
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$24.17
3/24/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC
CHECK
R14196
1790
MFA
Total Paid for ELECTRICAL: $48.34 $48.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
3/24/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC
CHECK
R14196
1790
MFA
Total Paid for PERMIT ISSUANCE: $91.85 $91.85
TOTALS:
Description: ZYSK / 8.OkW PV SYSTEM - (31) 260W PANELS W/(1) INVERTER
Type: SOLAR Subtype: Status: ISSUED
Applied: 2/17/2016 SKH
Approved: 3/24/2016 AOR
Parcel No: 604343006 Site Address: 79190 LAURIE CT CT LA QUINTA,CA 92253
Subdivision: TR 25363-1 Block: Lot: 25
Issued: 3/24/2016 MFA
Lot Scl Ft: 0 Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $17,732.00 Occupancy Type: Construction Type:
Expired: 9/20/2016 MFA
No. Buildings: 0 No. Stories: 0 No. Unites: 0
STAFF NAME
Details: 8.0kW SOLAR ARRAY - (31) 260W YINGLI PANELS+P300 SOLAREDGE OPTIMIZERS AND (1) SE7600-US-R AFCI SOLAREDGE INVERTER
[558SF) THIS PERMIT DOES NOT INCLUDE CHANGEOUT OF ELECTRICAL SERVICE, PER PLAN THIS SCOPE OF WORK WILL BE PERMITTED
SEPARATELY. 2013 CALIFORNIA ELECTRICAL CODE.
36
0
Applied to Approved
Approved.to Issued
Printed: Thursday, March 24, 2016 2:14:44 PM 1 of 3 R YSTEMs
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
EMAIL RECEIVED PAULA AT VIVINT SOLAR, THIS PROJECT
NEVER RECEIVED AN ORIGINAL REVIEW BASED ON PREVIOUS.
E-MAIL
AJ ORTEGA
3/17/2016
3/17/2016
REVIEWS OF SEPARATE PROJECTS ALL HAVING THE SAME
CALCULATION ERRORS, UPDATED 1ST REVIEW ITEM TO 3/17
WHEN REVISED PLANS WERE SUBMITTED.
EMAIL SENT TO PAULA (CONTRACTOR) THAT PLANS ARE
E-MAIL
AJ ORTEGA
3/24/2016
3/24/2016
APPROVED AND PERMIT IS READY TO ISSUE.
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY STATE
ZIP PHONE FAX EMAIL .
APPLICANT VIVINT SOLAR DEVELOPER LLC
3301 N THANKSGIVING
LEHI UT
84043 businesslicensing@vivi
WAY
nsolar.com
Printed: Thursday, March 24, 2016 2:14:44 PM 1 of 3 R YSTEMs
INSPECTIONS
PARENT PROJECTS
Printed: Thursday, March 24, 2016 2:14:44 PM 2 of 3
' CI?WSYSTEti1S.
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306 0
$1.00
$1.00
3/24/16
R14196
1790
CHECK
VIVINT SOLAR
MFA
DEVELOPER LLC
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00
$1.00
BSA:
PV SYSTEM - ARRAY,
101-0000-42403
0
$24.17
$24.17
3/24/16
R14196
1790
CHECK
VIVINT SOLAR
MFA
FIRST 20
DEVELOPER LLC
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$24.17
3/24/16
R14196
1790
CHECK
VIVINT SOLAR
MFA
FIRST 20 PC
DEVELOPER LLC
Total Paid for ELECTRICAL:
$48.34
$48.34
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
3/24/16
R14196
1790
CHECK
VIVINT SOLAR
MFA
DEVELOPER LLC
Total Paid for PERMIT ISSUANCE:
$91.85
$91.85
TOTALS:
$141.19
$141.19
INSPECTIONS
PARENT PROJECTS
Printed: Thursday, March 24, 2016 2:14:44 PM 2 of 3
' CI?WSYSTEti1S.
Permit Details PERMIT NUMBER I'
City of La Quinta BSOL20160046
Printed: Thursday, March 24, 2016 2:14:44 PM 3 of 3 Cgrull
SYSTrMs
ATTACHMENTS
Attachment Type
CREATED
OWNER'
DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
BSOL2016-0046 - 2ND
2ND SUBMITTAL SOLAR
SUBMITTAL SOLAR
DOC
3/17/2016
-A1 ORTEGA
PLAN (REVISED SHEETS
PLAN (REVISED SHEETS
0
ONLY)
ONLY).pdf
Printed: Thursday, March 24, 2016 2:14:44 PM 3 of 3 Cgrull
SYSTrMs
#
- CIL}/ Of Lc1 Quintd
Building 8L Safety Aivision
P.O. Box 1504,'78-495 Calle Tampico
.04b 4.Quinta, CA 92253 -:(760) 777-7012
Building Permit Application, and Tracking Sheet
Permit #
D�/a `
Project Address: I D Laurie C1.
owner's Name:. ✓ S K'
A. P. Number. 4 Q N 3 q3 0 Q
Address: 0 L Q (% V I t° ��• .
Legal Description:
City, ST, Zip: !4A t f t rcf— a�1:J
/
Contractor. i U h �o lar U j� v e law, f' L L C
Telephone: . /
Project Description: �nS d eA /4 / .
Address: S JJ J n c, P14
City, ST, Zip: CaiktdadC 9 2 x 3
-fd 0 g rq v I✓ 31 XA c s
Telephone:
State Lie. #: 3 City Lie. #;L' JC- 3I�rD
•
Arcfi., Engr., Designer.
Address:
City, ST, Zip:
Telephone: '` Construction Type: Occupancy:
State Lic. #: -�••. ::., Project type (circle one): New Add'a Alter Repair Demo
Name of Contact Person: Q j,rA 't"TO—W1ra R Sq. Ft.: # Stories: # Univ:
Telephone # of Contact Person: �.� a�%
Estimated Value of Project , 00
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
'Reed
TRACKING
PERMIT FEES
Plan Sets
Plan Cheek submitted
Item Amount
StruetuM Calm
Reviewed, ready for
Plan Check Deposit. .
Tmss Cates.
Called Contact era
Plan Check 8aiance,
Cates. Title 24 Ca.
Plans picked
.
Construction
Flood plain plan
Plans resubM
Mechanical
Grading plan
2'! Review, ready for rnrrectionsfissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN ROUSE:-
'"" Review; ready for correctionslissae
Developer Impact Fee
PlanningApproval.
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
0
DOCK -IT sysTem
Designed with the installer in mind.
Eco Fasten Solar specializes in solar roof attachments that are the easiest to install, most secure and cost-
effective solutions for installers. Eco Fasten offers a wide variety of standard products as well as custom
solutions, for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and
approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented
conical sealing system has been in service in the snow guard and solar industry for two decades.
FeaTures
• Fastest, easiest to level system on the market
• ETL listed to UL SUB 2703
• Class A Fire rating with Type 1 modules
• Integrated electrical bonding
sysTem comPonenTs
ROCK -IT IUIOUI'1T
Array sKirT
• SIMPLE- only 3 components
• Fixed wire management tray
• North-South adjustability of up to 4'
• Only one tool required (1/2" deep well socket)
ROCK -IT COUPLinG
A
TcoFasten Solar-
EcoFasten Solar products are protected by
the following U.S. Patents:
8,151,522 B2 8,153,700 B2 8,181,398 B2
8,166,713 B2 8,146,299 62 8,209,914 B2
8,245,454 B2 8,272,174 82 8,225,557 B2
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT MounT ASsemBLY
NOTe: ITems 1-12 SHIP assemBLeD
1 S/16"-18 x 1.5" Hex Flange Bolt 300 Series SS
2 Rock -It Mid -Clamp 6005A -T5
3 Compression Spring 300 Series SS
4 Tie Plate 6005A -T5 AL
5 Rock -It Shelf 6005A -T5 AL
6 Flange Level Nut 300 Series SS
7 Packaging 0 -Ring (Remove Prior to Installation)
8 Rock -It Pedestal 6005A -T5 AL
9 3/8" ID Star Lock Washer 300 Series SS
10 3/8"-16 Hex Tap Bolt 300 Series SS
11 5/16"-18 x .375" Hex Flange Bolt 300 Series SS
12 Rock -It -Slide 6005A -T5 AL
13 5/16" ID EPDM Bonded Washer 300 Series SS
14 5/16" x 4" 1 lex Lag Screw or 5/16"-18 X 1.50"
Hex Bolt 300 Series SS
ROCK -IT COUPUnG ASSeMBLY
NOTe: ITems 1-4 SHIP assemBLeD
1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS
2 Rock -It Coupling Mid Clamp 6005A -T5 AL
3 Compression Spring 300 Series SS
4 Rock -It Coupling Shelf 6005A -TS AL
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
array LAYOUT
• Find the required structural attachment points.
Mark these using a vertical (N -S) chalk line on the
center of the rafters.
• Spacing may vary depending upon project specific
structural requirements; i.e. high snow and wind
load areas may require lesser bracket spacing in
the E -W axis vs. the maximum spacing. Max spacing
is 48" for portrait orientation and 72" for landscape
orientation. Consult project layout diagram for
project specific bracket spacing on the roof.
• Install Rock -It Mounts to predetermined mount
spacing.
• The array skirt sections are the width of a typical
60 cell module - use the array skirt as a guide to
lay out module placement.
Note: The distance between the rows of mounts is calculated by the module dimension N -S plus 1 3/8"
(35mm). Lag screw should be Installed as close to center of exposed shingle as possible.
GreenFasTen FLaSHinG insTaLL
1 Locate the rafters and snap horizontal and vertical lines to mark the installation
position for each GreenFaster flashing.
2 Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. Eco Fasten Solar
recommends an EPDM mastic-
3
astic3 Insert the flashing so the top part. is under the next row of shingles and pushed far
enough up slope to prevent water infiltration through vertical joint in shingles. The
leading edge of flashing must outt against upper row of nails to prevent turning
when torqued.
4 Line up pilot hole with GreenFasten flashing hole.
Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed
hole in the flashing and into the rafter.
Torque: The range is between 100-140 torque inch -pounds depending on the type
of wood and time of year. The visual indicator for proper torque is when the EPDM
on the underside of the bonded washer begins to push out the sides as the washer
compresses. If using an impact wrench to install the fasteners be careful not to over
torque the fastener. You may need to stop and use a ratchet to finish the install.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT SCJ- STem II'ISTaLL
ROCK -IT
SYSTEM'
Install EcoFasten Solar Flashing with Rock -It Mounts
Follow GreenFasten Install instructions for flashing and bracket install on composition shingle roofs.
Optimum vertical distance between lag bolts is 1 3/8" plus module dimension.
Set mounts on eave most row so that the Rock -It Pedestal Is on the South end of Rock -It Slide. (ex. image 1)
Set mounts on all upper rows so that the Rock -It Pedestal is on the North end of Rock -It Slide. (ex. image 6)
2 Install Array Skirt to Eave Mounts
• Install array skirt starting on west side of array and move east.
3-4 Attach Couplings to Array Skirt
Tighten the west most array skirt bolt on coupling first.
When tightening the east bolt the array skirt sections will be drawn together.
5 Align and Straighten First Row of the Rock -It System with Array Skirt
Use North-South adjustment of the Rock -It pedestal to straighten array skirt.
Tighten screw on side of Rock -It Pedestal to secure it to the Rock -It Side.
Adjust Flange Level Nut to level the system (optional - can be leveled durirg or after installation)
Install 1 st Row of PV Modules
6_7
Slide Rock -It Mounts that are upslope down to engage top of first module.
Note: Make sure cable tray is facing upslope.
Torque 1 st and 2nd row of mid -clamps on Rock -It Mounts and Rock -it Couplings to 150 in -lbs.
Note: Torque setting may vary according to module manufacturer.
8_9 Install Balance of PV Modules
Secure wire and electrical components in built in wire tray on Rock -It Mounts and Couplings.
Install next row of panels and torque mid -clamps to secure modules.
Repeat install for all remaining rows of modules.
10 Level the Rock -It System
• When assembly is complete, level the entire system by adjusting Flange Level Nuts.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
IGrounDInG LUG nsTaLL
Necessary Components:
- Burndy CL50-1 TN Ground Lug (UL Listing #KDER.E9999)
- 14 AWG - 4 AWG Copper Ground Wire
- 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS)
- 8-32 Serrated Flange Nut (300 Series SS)
- 11 /32" and 1/4" wrenches or ratchets/sockets
1 The Ground Lug is installed into the T slot on the Rock -It Mount.
2 Slide the Flange Head Bolton the Ground Lug into T slot on Rock -It Mount.
3 Tighten Flange Nut/Bolt.
4 Place wire in Ground Lug channel and tighten set screw to complete assembly.
OonD1nG AssemBLY anD BonDinG PATH
Bond Path
Grounding Lug
- Equipment Grounding
Conductor (EGO}
gcnMaly to earth
ground
Rock -it Coupling
Rock -It Mount
Integrated Bonding .
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ITHermaL ExPansion ano BonDinG
A thermal expansion gap is
required per each continuous
100' length of modules.
Omit a coupling and leave a 2"
gap in the array skirt and also
between the modules at that
point.
BracKeT sPacinG
Portrait Orientation
— Bond Path
® Wounding Lug
Equlpptt�t�onti2Wding
�—
con 0r
(EGC}
generaly to eanh
grtwnd
Rack-ItCoupling'
■ Rock -It Mount
Landscape Orientation
Maximum bracket spacing in Maximum bracket spacing in
Portrait orientation is 48" OC. landscape orientation is 72" OC.
Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load
areas may require lesser spacing E -W than the maximum.
sTaGGereD LAYOUT I canTILever anD oFFseT
I Staggered Mounting Points
O Rock -It Mount Rock -It Coupling Cantilever: Maximum cantilever is 25% of module width. For portrait
orientation installations, check layout prior to installing.
The array layout instructions in this installation manual offer a
general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow
factors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
•
�
tt
a
>r
r
if
as
�I
�l
O Rock -It Mount Rock -It Coupling Cantilever: Maximum cantilever is 25% of module width. For portrait
orientation installations, check layout prior to installing.
The array layout instructions in this installation manual offer a
general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow
factors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT
SYSTQ�
ROCK -IT SYSTem
• Fastest, easiest to level system on the market
• ETL listed to UL SUB 2703
• Class A Fire rating with Type 1 modules
• Integrated electrical bonding
• SIMPLE- only 3 components
• Fixed wire management tray
• North-South adjustability of up to 4"
• Only one tool required (1 /2" deep well socket)
Max No. of Panels
300 Modules per ground lug
Materials
300 Series Stainless,
6000 Series Aluminum
Max System Voltage
1000VDC
Coating
Black Andodization/Mill Finish
Class A Fire Rating
With UL 1703 Type 1 Rated
Lug Specifications
Burndy CL50-1 TN Ground Lug
Modules
(UL Listing #KDER E9999)
Leveling Range
3-4"
Ground Wire
14 AWG- 4 AWG Copper
Per above Lug spec.
Ground Wire
Rock -It Slide Range
4"
Max Module Size
64.96"(1650mm) x
39.05"(992mm) x 2"(50mm)
Min/Max Roof Slope
5:12/12:12
Max Downforce/Uplift Rating
45 PSF
Max Anchor Spacing
72"
Rock -It Mount Load Rating
547lbs with Single 5/16" Lag 3.0
Safety Factor
Skirt Box QTY
6 units
Slide Fastening Hole
5/16" diameter
Mount Box QTY
12 units
Module Cantilever
Lesser of 25% Width, or Module
Installation Manual
Coupling Box QTY
12 units
Warranty
10 Year Material 77o79
Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC
Standards: UL 2703, UL 1703
.01 r4
TOUS
www.ecofastensolar.com
UA
QC�DIEc®]Fasten Solar
info@ecofastensolar.com
877-859-3947
solar- •.
SolarEdge Single Phas
For North America
SE3000A-US / SE380OA-US / SE5000P
SE760OA-US / SE10000A-US / SE1140(
0
F3
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance
Superior efficiency (98%)
Small, lightweight and easy to install on provided bracket
Built-in module -level monitoring
Internet connection through Ethernet or Wireless
— Outdoor and indoor installation
— Fixed voltage inverter, DC/AC conversion only
— Pre -assembled Safety Switch for faster installation
Optional — revenue grade data, ANSI C12.1
USA -GERMANY-I-rALY-FRANCE-JAPAN Ch: NA-AUSrRAIIA I-IENEI HER I.AN05 ISRAEI www.solaredge.us
solar ., Single Phase Inverters for North America
SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/
SE7600A-US/SE10000A-US/SE1140OA-US
OUTPUT
Nominal AC Power Output
SE3000A-US j SE3800A-US I SES000A-US i SE6000A-US I SE760OA-US ' SE10000A• US I SE1140OA-US
I 3000 38M 5000 60001 7600 9980 @ 208V 11400
10000 @ 240V
5400 @ 208V 1 i 10800 @ 2l)SV
VA
Max. AC Power Output
3300
4150 6000 8350
12000
VA
I
5450 �240V } (10950 @240V
AC Output Voltage Min: Nom: Max.0 I
I ✓
{
1
183 - 208 - 229 Vac
AC Output Voltage Min: Nom: Max.l'I 1
J
J J
J J J
J
211- 240 - 264 Vac
AC Frequency Min: Nom: Max.t't
59.3 - 60 - 60.5 (with
HI country setting 57 - 60 - 60.5)
............
Hz
Max. Continuous Output Current
12.5 16
24 @ 208V
25
I 48 @ 208V
32
47.5
A
I ...21.@
240V ...................
42
....................@ 240V....
GF DI Threshold }
1
A
Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes
Yes
INPUT
_ -
Recommended Max. DC Powert'!
1
3750 4750 6250 7500 9500 12400
14250
W
Transformer -less, Ungrounded
Yes
Max. Input Voltage
500
Vdc
Nom. OC Input Voltage i
325 @ 208V / 350 @ 240V
Vdc
1
Max. Input Currents,I
1.6.5 (0 I08V 33 C&I 208V t
9.5 13 UI 2.l 34.5
Adc
I
15.5 @ 240V 30,5 @ 240V
Max. Input Short Circuit Current (
4S
Adc
Reverse -Polarity Protection
Yes
Ground -Fault Isolation Detection
600WtSensitivity
Maximum Inverter Efficiency
97.7 } 98.2 98.3 98.3 1 98 98 98
' 95
CEC Weighted Efficiency
97,5 98 97.5 @ 208V 97 5 97.5 97 @ Z08V 97.5
%
98, @ 240V 97.5 �: 240V
Nighttime Power Consumption_ _
<2.5 I <4
W
ADDITIONAL FEATURES
`i _ _
Supported Communication Interfaces
RS48S, RS232, Ethernet, ZlgBee (optional)
Revenue Grade Data, ANSI C12.1
Optional"'
Rapid Shutdown - NEC 2014 69D.12
Functionality enabled when SolarEdge rapid_ shutdown kit is instailledpl
STANDARD COMPLIANCE_
Safety (
U1174.1. 0116998, U11998 , CSA 2202
Grid Connection Standards
IEEE1547
Emissions
-
FCC partly class 0
!!
!_
INSTALLATION SPECIFICATIONS
V
AC output conduit size / AWG range
3/4" minimum / 16-6 AWG 3/4" minimum / 8.3 AWG
DC input conduit size / 0 o strings /
r
3/4" minimum / 1-2 strings / 16.6 AWG 3/4" minimum 11-2 strings / 14-6 AWG
AWG range , (
Dimensions with Safety Switch y
30.5 x 12:5 x,7 /
30.S -x 12S x 7.5/
in/
(HxWxD) I
775 x-315 x 172
30.5x12.5x10.S/775x315x260
775.x 315 x 191
mm
Weight with Safety. Switch I
Si.2./ 23.2
S4.7/ 24.7 88.4/40.1
Ib / kg
Cooling
Natural Convection Fans (user replaceable)
Noise.
< 25 < SO
dBA
Min. -Max. Operating Temperature
-13 to +140/ •25 to +60 (-40 to +60 version availablere)
'F /'C
Range
Protection Rating
NEMA 3R
For other regional settings please confect SolarEdge support
6kW and Iowan; Untited to 135%of AC power; 7 &W and
hlgher: Umlted to 125% for locations where the yearly average high temperature is above 777/25'Cand to 13s%ter locations where It Is below 77'F/25'C
F-ordetailed Information, refer to wte //wwwiguredne.us/Nlef/ndfsrlrrreesh
I. m,usis.M& -,d.adr
In A high ercurrent source maybe used; the inverter will limit its Input current to the values stated
I'I Revenue grade inverter P/N; 5ExxxxA-US000NNR2
I51 Rapid shutdown kit P/N: SE1000-RSO-S1
161 -40 version P/N: SExxxxA-USOOONNU4
0
solar -••
SolarEdge Power Optimizer
Module Add -On For Forth America
P300 / P400 / P405
PV power optimization at the module -level
— Up to 25% more energy
— Superior efficiency (99.5%,)
— Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
- Flexible system design for maximum space utilization
— Fast installation with a single bolt
— Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter safety
USA - GERMANY - iFALY • FRANCE - JAPAN - ChINA - ISRAF, - AUSFRALIA www.solaredge.us
solar •.• :.
SolarEdge Power Optimizer
Module Add -On for North America
P300 / P400 / P405
PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE Z08V
A SOLAREDGE INVERTERI�1
Minimum String Length 8 10
(Power Optimizers!
Maximum String Length 25 25
(Power Optimizers)
Maximum Power per String 5250 6000
Parallel Strings of Different Lengths Yes
or Orientations
n It is not allowed to mix P405 with P300/P410/P600/P700 in one string
THREE PHASE 480V
18
50
12750 W
t
P300 + P400 P405
i
(for 60 cell madul� — i for 7 & 96 -cell modules) - ; (far thin film modules)
-----. _-Z -- .
INPUT
Rated Input DC Power"' )
300 + 400 405
W
Absolute Maximum Input Voltage
48 80 125
Vdc
(Voc at lowest temperature)
t
MPPT Operating Range (
8-48 8.80 12.5-105
Vdc
Maximum Short Circuit Current (Isc)
10
Adc
Maximum DC Input Current
L2.S
Adc
Maximum Efficiency
X9.5
%
Weighted Efficiency
98.8
/p
Overvoltage Category_
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current
15
I Adc
Maximum Output Voltage_
85
j Vdc
_ _ __ _6_0 _ _ -��,- - _
OUTPUT DURING_STANOBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety OutpuLVolta - Per Power Optimize - ^- 1
—i -
j Vdc
STANDARD COMPLIANCE
_
EMC
FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety
IEC62109-1(class II safety), UL1741
RoHS _
- Yes -
INSTALLATION SPECIFICATIONS
-
Maximum Allowed System Voltage i
'15.55
1000
Vdc
Pxxx-2 series
141 x 212 x 40.5 x 8.34 x 1.59
mm / in
Dimensions (W x L x H)
128x152x27.5/ 128x151x.35/ i 128x152x48/
Pxxx-5 seriesmm
5 x 5.97 x 1.08 5x5.97, x.-1.37. ( 5 x 5.97 x 1.89
/ in
Pxxx-2 series S
Weight (including cables) :
.95.0/2.1
gr / ib
Pxxx-5 series i
770/1.7 i 930 / 2.05 ! 930/2.05
; gr / ib
Input Connector
MC4 Compatible
Output Wire Type / Connector +
Double Insulated; Amphenol
Output Wire Length i
0.95 / 3.0 I 1.2/3.9
m / ft
Operating Temperature Range
-40 - +85 / -40 -+185
'C /'F
i
j Pxxx-2 series
IP65 / NEMA4
Protection Rating
Pxxx-5 series
IP68 / NEMA6P
Relative Humidity
0-100
t[t Rated STC power of the module. Module of up to+j%power tolerance allowed
PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE Z08V
A SOLAREDGE INVERTERI�1
Minimum String Length 8 10
(Power Optimizers!
Maximum String Length 25 25
(Power Optimizers)
Maximum Power per String 5250 6000
Parallel Strings of Different Lengths Yes
or Orientations
n It is not allowed to mix P405 with P300/P410/P600/P700 in one string
THREE PHASE 480V
18
50
12750 W
t
,'I, �D� 0 ��D- () O�50 0 O�3D
RAINB
BUSTER
arrantny
e i� 1
UHra Flexible Roof Tile Adhesive/Sealant
prey'eaft Moog &emit and MML.'em F iffe
ROOF TILE 1 SHINGLES 1 SHEET METAL I FLASHING I VENTS I GUTTERS I TRIM I NEW CONSTRUCTION. I REPAIRS.
Roofs are on the front line in preventing water intrusion
p High -Grade Polyurethane Formulation
and are subjected to the most extreme wind and weather
D Permanently Secures. Roof Tile
conditions. To prevent roof damage and leaks, an adhesive/
b Non -Shrinking; Permanently Flexible
sealant must be a standout performer. RainBuster 850
Ultra -Flexible Roof Tile Adhesive/Sealant is specified by
D UV Resistant; Flexes to Prevent Broken Tiles
leading builders and trusted by quality -minded contractors
D Withstands Extreme Wind, and Foot Traffic
to prevent roof leaks. Unlike traditional roofing; cements.
p Seals Roofing Joints including Flashing
and mastics, RainBuster 850, offers a high-grade polyurethane
D Withstands Extreme Weather & Temperature
formulation, permanent flexibility and powerful adhesion.
D Non -Sag to Prevent Tile Slip
When used as a roof tile adhesive, RainBuster 850 shines.
P Adheres to Damp Surfaces
as it flexes with hurricane force wind uplift, foot traffic, and
D Paintable (See Painting Section)
seismic activity to prevent broken tiles. When applied to
D Non -Flammable
flashing, vents and gutters, RainBuster 85G permanently
p VOC, CARB, and AOMD Compliant
seals joints to effectively divert water away from the home.
(* lifetime Warranty
The Ultimate Roof Tile
RAIN'
BUSTER
ER
-:rte •r- "
op i d s ri Inc. •0 �n S Van GA 1105 • 860
1 16to ind str a co
J^
e
"N e
Ultra Flexible Roof Til PRO�Fh
oma
BUSTER Adhesive/Sealant - ,
Field Proven to Prevent Roof Leaks
DESCRIPTION TILE -TO -TILE BONDIMO
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/Sealant ' o RainBuster 850 is ideal tar adhering roof tie to -
is the high quality standard in the prevention of roof toe in valley, ridge, hip, rake and general roof tile
leaks. Its technologically advanced polyurethane formu- Q installation. Secures cut tiles when mechanical
lation has been specifically designed to provide roofing { fasteners cannot be used. Rain8uster 850 provides
application solutions. RainBuster 850 performs equally additional protection�against wind uplift, seismic
well when used as a tile adhesive or as a sealant on )9►; activity, and tile damage. Prevents tile chatter.
flashing, vents, and other roof penetrations. RainBuster ` " RainBuster 850 seals nail entry points created
850 is ideal for specifying as a multi -use roofing adhe "a► during tile installation. RainBuster 850 flexes to
sive/sealant. it is ideal for both new construction and ? • o y >y bonded and prevent broken file and root.leaks.
repairs.
PACKAGING, SHELF LIFE & STORAGE
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/
Sealant is available in standard 300 ml cartridges
(packaged 24 per case) and 592 ml sausage tubes
(packaged 12 per case). The shelf life is 12 months.
Store in a cool, dry place below 80°F for maximum
shelf life.
AVAILABILITY AND COST
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/
Sealant is competitively priced and widely available.
Please contact Top Industrial, Inc. at 800-473-1617 or
see www.topindustrial.com for a supplier nearest you.
AUTHORIZATIONS
Meets or exceeds:
ASTM C920 Type S, Grade NS, (lass 35, use NT, A and M
Federal Specification TT -S -00230C (COM-NBS)
Type II, Class A
Canadian Specification CAWCGSB-19,13-MB7
ENVIRONMENTALLY FRIENDLY
• Oualifies for LEED Credit from U.S. Green Building
Council: l pt EQ Credit 4.13
• Ouallfies for NAHB Green Build Credits:
5 pts Global Impact Credit 7.1.3
• VOC Compliant under AND and CARB
LIFETIME WARRANTY
Top Industrial warrants this adhesive to perform as
described on its package and associated data sheet for
a period of 100 years from the date of purchase. See
next page for further warranty details.
FLASNINO LAP JOINTS
RainBuster 860 is Ideal for sealing varied 'lap joints
where two lengths of flashing meet such assn valleys.
RainBuster 850• flexes to maintain ar permanently
bonded watertight seal, For best results, apply a
continuous 1/2" bead to both the inside and
outside of the joint. Tool the outside joint bead
as necessary (see application and tooling sec-
tions). Available in the multiple colors and
paintable (see painting section).
RainBuster 850 is: ideal for use where flashing.
r terminates at walls and chimneys. RainBuster 850,
provides outstanding adhesion to both metal and
common exterior wall surfaces. RainBuster 850
flexes Wmalntaln a, wateright..seal. For best
results,. apply a continuous 1/2' bead to both
the inside and outside of•the joint. Tool the out-
side joint bead as necessary (see application
and tooling sections). Available in the multiple colors
and paintable (see painting section)'.
VBNTS AND,¢WIANIIEY CAPS
i RainBuster 850: sub joint in vents, chimney caps
and other roofing envelope penetrations. Also secures
verd strictures to underlying bases. RainBuster 850
flexes to maintain a watertight seal. For best results,
apply a continuous 172" bead -to both the.inside
and outside of the joint. Tool the outside joint
bead as necessary (see application and tooling
sections). Available in the, multiple colors and
paintable (see painting section).
Ardrr Seats seems ingutters, gutter assemblies, and downspouts.
duipmOoMWSf *Ow Adheres shingles and supplements -mechanical fasteners.
f .Pertna►rently seals seams and tastaner enty holes.
MMSupplemenls mechanical fasteners and seals seams. Can significantly reduce vibration raw
blrrdrr4jias�rtSeab tears in fell and wrderlayment. Bridge entire tear and tool as necessary.
Mltrf i$f1,oe /mt,/rbll I 'Adheres to to damp surfaces. Remove standing water prior to application.
Top Industrial, Inc. • 15010 Keswick St., Van Nuys, CA 91405 • 800-473-1617 • www:topindustrial.com
APPLICATION: Easy to apply with conventional caulking equipment. Application temperature range: 20F —120F. If application air temperatures are below 40F, con- j
dition product at 70F prior to using for best results. Cut tip at a 45 -degree angle. Location of cut will determine desired bead thickness. Puncture seal. Apply sealant to joint. i1
Typically, minimum 3/8"-1/2" beads should be used for proper bonding and sealing. Fill joints in continuous beads from deepest point and avoid overlapping of sealant to
prevent air entrapment. Adhesive/sealant should wet the joint wall surfaces. With lap joints, apply adhesive/sealant to both inside and outside of joint for best results. `
Adhesive/sealant provides 1-3 hour working time before skinning. Adhesivetsealant cures with exposure to normal atmospheric moisture with full cure in 1-3 days depending `
on humidity. May be used on damp surfaces; take steps to remove standing water. For best results, use opened cartridges and sausages the same day.
APPROPRIATE SURFACES. RainBuster 850
is appropriate for use in new construction
and repairs on a wide range of common
roofing materials including concrete, clay,
slate, composition, fiber -cement, asphalt
saturated shingles, masonry, mortar,metals
Including galvanized, aluminum, and
copper, underlayment and felts, plastics
Including PVC, vinyl, fiberglass, nails, and
wood.
PREPARATION: For best adhesion results,
surfaces should be dean, and free from
dirt dust, oils, release agents, standing.
water, old sealants, or other contaminants.
Dust and loose particles should be blown
off surfaces.
FIELD PRETEST: Due to the varled nature
of construction substrates, field-test.
adhesivelsealard on actual surfaces prior
to beginning work User must determine it
results including adhesion are acceptable.
TOOLM t requriredt Whig is recommended.
within 20 minutes after application. Tooling
should be done in one continuous stroke.
Techniques using solvents or soaps are not
recommended. t masking, remove tape
Immediately after tooling.
CLEAN UP: Clean hands safely with
RainBuster Top Towels (citrus wipes).
Mineral spirits and other commercial
solvents such as xylene, toluene, or
methyl ethyl ketone (MEIQ may be used
to clean up excess smears and tools. The
use of solvents may be hazardous to your
heath. Keep away from open flame. and
use in well -ventilated area. Follow
solvent manufacturer's instructions.
Cured adhesive/sealant is difficult to.
remove and must be done so by,abrasion
or other mechanical means.
PAINTING OVER RAINBUSTER 850: For
best results, apply paint over RalnBuster
850 adhesive/sealant 72 hours after
application. High quality 1004E acrylic
paints and primers are recommended:
Many roofing specific spray paints are
acceptable. Avoid the use of oil base
paints as they may exhibit a slow/non-
curing condition when in contact with
adhesive/sealant Paint when weather
and temperature conditions meet paint
manufacturer requirements. Feld pre-test
for suitability, of paint and painting
process is required. Contractor must
determine suitability. Consult Top
Industrial for further Information.
MAINTENANCE No maintenance should
be needed. If adhesivelsealant becomes
damaged, remove damaged portion. Clean
surfaces in damaged area, and, repair with
fresh RainBuster 850.
PRIMING PRIOR TO APPLICATION:
Generally, priming is not required. If
adhesion pretest is unacceptable, consul.
Top industrial for recommendations.
APPLICATION OVER GLAZED, PRE-
PAINTED, OR PRE -PRIMED SURFACES:
Glazed, pre -painted and pre -primed
surfaces typically do nothave the adhesive
quality or flexibility of RainBuster 850
adhesive/sealant. lack of adhesive/sealant
contact with raw substrate may inhibit
abllfly to maintain bond and seal. Glaze,
paint or primer may pull away from raw
substrate with joint movement
USE WITH ASPHALT BASED SELF -
ADHERED FLASHING (A.K.A. SBS modi-
fied asphalt & bituminous materiaq:
When used appropriately, RainBuster 850
can be used successfully with asphalt -
based flashings. Unlimited contact is
acceptable between adhesive/sealant
and the permanent polyethylene/plastic—
based facer side of set -adhered asphalt
flashings. Steps must be taken to minimize
contact with the adhesive side of asphalt
flashings. Plasticizers in adhesivelsealant
may accelerate the normal moisterdng and
softening of asphalt that occurs with heat
Do not apply adhesive/sealant directly to
adhesive asphalt side of flashing. Do not
apply adhesive side of asphalt flashing
directly over adhesiva/sealent. Remove
excess sealant prior to application of
adhesive asphalt side of flashing: User
must determine suitability through field
pretest Consult Top Industrial for further
information.
LIMITATIONS: Suitability for each intended
use must be determined by the user using
the information found in this data sheet and
an application pretest
• Not for use over standing surface water
or surface frost
• Not designed to replace use of
mechanical fasteners.
• Not for use where subjected to constant
wafer immersion.
• When painted, user must determine
paint suitability. See"Painting" section for
detailed limitations.
• When used with asphalt -based self -
adhered lashings, user must determine
suitability through field pretest. See "Use
With Asphalt" section for detailed
Ilmitations.
• Do not cure in presence of curing
silicone sealants. This may interfere
with RainBuster 850's curing process.
• Avoid sealant contact with solvent
cleaners during cure. This may interfere
with RainBuster 850's curing process.
PRECAUTION: Combustible vapor.
Uncured sealant may cause allergic skin
reaction and'eye, skin and,respiratory tract
Irritation. Keep --sway from sparks and
flame. Avoid contact with eyes, skin and
clothing. Avoid prolonged exposure to
vapors. Use only with adequate ventilation.
Wear pmtectve clothing during handling.
Wash thoroughly after handling. KEEP OUT
OF REACH OF CHILDREN. See material
safety data sheet before use (canted Top
Industrial or dstribulor).
FOR CONSTRUCTION AND INDUSTRIAL
USIEBY QU LLIFIED CRAFTSMAN.
FIRST AID: If inhaled, remove.to fresh air.
it breathing Is difficult, give oxygen and call
a physician. In case of contact with
uncured sealant, Immediately flush eyes
with water for at least 15 minutes and
wash skin with soap and water after using
IlainBursterTop Towels (citrus wipes). Call a
physician it irrtfabon persists. See material
safety data sheet for more detail.
LIFETIME WARRANTY DETAILS: Top
Industrial, Inc. warrants this sealant/adhe-
sive to perform as. described on its pack-
age and associated data sheet for a period
of, 100 years from the date of purchase.
Upon proof of purchase, Top Industrial's
sole liability, expressed or implied, shall be
to replace sealanVadhesive proven defec-
tive, and is limited to the stated selling
price. This warranty is not transferable
from the original purchaser. In no event
shall Top Industrial' be liable for conse-
quenfial, or incidental damages, resulting
from the use of its sealant products.
0�0
RMNI
BUSTER
., _�ae9iAeC-J
~ avrr
fi
4
Top Industrial, Inc. • 15010 Keswick St., Van Nuys, CA 91405 • 800-473-1617 • www:topindustrial.com
BUSTER
The Ultimate
Roof Tile
Adhesive/
Sealant
Ultra Flexible Roof Tile Adhesive/Sealant
Prevents Roof Leaks and Broken i?1'e
ROOF TILE I SHINGLES I SHEET METAL 1 RASH I VENTS I MIT ERS I TRIM I NEW OOWTFtlICM I REPAIRS
[AVAILABLE COLORS
Coral Tarry Cotta Tan Gmyr ($t m) Brown Black
(Bm=)
1�hUSA Uy
�/ hfnAt in
� sa
For more than 25 years,
Top Industrial's RainBuster
d has been dusted to prevent leaks in the building
,elope and squeaks in floor structures. Today that
ist runs deep - RainBuster is specified by the
Nation's leading builders and dusted by scores of
respected contractors.
The reason for the trust is simple...
RainBuster products and services outperform
other brands in preventing leak and squeak
related call-backs.
PHYSCAL PROPERl1ES
Skin rine.................................... ..................... 1-3 hour,
Cure Time ............................... :........................... 1-3 days
% Solids.......................................................96% to 99%
Paintable....:....................................Yes — See limitations
Sag or Slump...........................................................None
Clean-Up....................................................Citrus Cleaner
Shrinkage....................................................................NII
Chalking or Craring::,..;,. ........_... NTP
"PICAL PERFORMANCE CHARACTER/SRCS
After 7 days cure at 77 deg. F and 50% RHS
Hardness (Shore A): ................................ 32 ASTM D 2240
Tensile.Strength ......................Up to 250 psi ASTM D 412
Elongation.._ ..................................... 1400% ASTM D 412
Adhesion, In Pee[ ......................................... _....... >33 piw
...........................................T-S-00230C/ASTM C 794
Stain& Color Change .... _ ..................................:.......None
TT-S-00230C/ASTM C 510
0zonej Resistance ...............................................Excellent
Joint Movement Capability ..................................... +35%
ASTM C719, 73°F cure / 73°F cycling.
UV Resistance ........................Excellent - ASTM C 793-75
Water Resistance ................................................Excellent
W18tMll® BY.
300 ML CARTRIDGES
APPROXIMATE LINEAR FEET PER CARTRIDGE
BEAD WIDTH, INCHES
1/4" 3/8" 1/r 55/80
3/4"
7/8"
1"
..
1/8"
49:6 33.1 24.8 20.0.
16.5
14.2
12.4 '
1/4-
24.8 20.0 12.4 10.0
8.3
7.1
6.2
0
—
3/8"
— 11.0 8.3 6.6
5.5
4.7
4.1.
1/2"
— — 6.2 5.0
4.1
3:5
11.
1�hUSA Uy
�/ hfnAt in
� sa
For more than 25 years,
Top Industrial's RainBuster
d has been dusted to prevent leaks in the building
,elope and squeaks in floor structures. Today that
ist runs deep - RainBuster is specified by the
Nation's leading builders and dusted by scores of
respected contractors.
The reason for the trust is simple...
RainBuster products and services outperform
other brands in preventing leak and squeak
related call-backs.
PHYSCAL PROPERl1ES
Skin rine.................................... ..................... 1-3 hour,
Cure Time ............................... :........................... 1-3 days
% Solids.......................................................96% to 99%
Paintable....:....................................Yes — See limitations
Sag or Slump...........................................................None
Clean-Up....................................................Citrus Cleaner
Shrinkage....................................................................NII
Chalking or Craring::,..;,. ........_... NTP
"PICAL PERFORMANCE CHARACTER/SRCS
After 7 days cure at 77 deg. F and 50% RHS
Hardness (Shore A): ................................ 32 ASTM D 2240
Tensile.Strength ......................Up to 250 psi ASTM D 412
Elongation.._ ..................................... 1400% ASTM D 412
Adhesion, In Pee[ ......................................... _....... >33 piw
...........................................T-S-00230C/ASTM C 794
Stain& Color Change .... _ ..................................:.......None
TT-S-00230C/ASTM C 510
0zonej Resistance ...............................................Excellent
Joint Movement Capability ..................................... +35%
ASTM C719, 73°F cure / 73°F cycling.
UV Resistance ........................Excellent - ASTM C 793-75
Water Resistance ................................................Excellent
W18tMll® BY.
Product Data Sheet DU222RB
Safety Switch, 60A, 240VAC, Non -Fusible,
General Duty, 2 -Pole
Technical Characteristics
Msc3uAat✓ :a
bYSChnelder 1Elcctr1c
List Price $353.00 USD
Availability Stock Item: This Item is normally stocked In our distribution facility.
Wire Size
#10 to #2 AWG(AI) - #14 to #2 AWG(Cu)
Action
Single Throw
Ampere Rating
60A
Approvals
UL Listed File Number E2875
Enclosure Type
Rainproof and Sleet/Ice proof (Indoor/Outdoor)
Enclosure Rating
NEMA 3R
Factory Installed Neutral
No
Maximum Voltage Rating
240VAC
Disconnect Type
Non -Fusible
Terminal Type
Lugs
Mounting Type
Surface
Type of Duty
General Duty
Number of Poles
2 -Pole
Shipping and Ordering
Category
00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R
Discount Schedule
DELA
GTIN
00785901491491
Package Quantity
1
Weight
4.7 lbs.
Availability Code
Stock Item: This item is normally stocked in our distribution facility.
Returnability
Y
Country of Origin
MX
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.
® 2009 Schneider Bectric. All rights reserved. Schneider
VEIectric