BSOL2015-021178-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Tdy 4 s4P QuiKm
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BSOL2015-0211
Property Address:
44300 OCOTILLO DR
APN:
604193003
Application Description:
MYERS/5.415kW PV SYSTEM
Property Zoning:
Application Valuation:
$20,000.00
Applicant:
c
'
ECO FRIENDLY ENERGY COMPANY
' �F,
360 EAST FIRST STREET STE #800
TUSTIN, CA 92780
(19) PAN ELS/(19)MICROINV+200A MSP
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: A. B. C30, C46 License No.: 10012857
Date: 1 ! r 115Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(J) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
37
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
(714)824-0047
Llc. No.: 1002357
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of a work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with thos provisions.
Date: (S Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST. AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-ment ne property for inspection purposes. ;
Date: (( Signature (Applicant or Agent):
Date:., 11/4/2015
. r
Owner:
w
WAYNE MYERS
,n
mt
92253
c
'
' �F,
Contractor:`
ECO FRIENDLY ENERGY COMPANY
360 EAST FIRST STREET STE`MlOD- v
TUSTIN, CA 92780
(714)824-0047
Llc. No.: 1002357
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of a work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with thos provisions.
Date: (S Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST. AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-ment ne property for inspection purposes. ;
Date: (( Signature (Applicant or Agent):
DESCRIPTION
FINANCIAL •• 1
ACCOUNT QTY AMOUNT PAID PAID DATE
BSAS SB1473 FEE
101-0000-20306 0 $1.00 $0.00
PAID BY
METHOD RECEIPT # CHECK # CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT
101-0000-42403
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT PC
101-0000-42600
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for ELECTRICAL: $96.68 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
PAID BY,
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:00
17.
0 0 0
`y OF
Description: MYERS/5.415kW PV SYSTEM -(19) PANELS/(19)MICROINV+200A MSP
Type: SOLAR Subtype: Status: APPROVED
Applied: 10/22/2015 SGU
Approved: 11/2/2015 JFU
Parcel No: 604193003 Site Address: 44300 OCOTILLO DR LA QUINTA,CA 92253
Subdivision: TR 24517 Block: Lot: 63
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $20,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
NOTIFIED JESUS PEREZ W/ ECO FRIENDLY ENERGY CO. (818 -
251-0752) THAT PLANS WERE APPROVED AND PERMIT WAS
READY TO ISSUE.
Details: 5.415 kW SOLAR ARRAY - (19) 285W SOLARWORLD SW 285 MONO PANELS W/ (19) ENPHASE M250 MICROINVERTERS + MAIN
SERVICE PANEL UPGRADE TO 200A [342SF] 2013 CALIFORNIA ELECTRICAL CODE.
.-._,1 Applied to Approved
Printed: Wednesday, November 04, 2015 10:54:10 AM 1 of 2
hTWSYSiEMS
ADDITIONAL
CHRONOLOGY TYPE STAFF NAME-
CHRONOLOGY.
ACTION DATE
COMPLETION DATE NOTES
TELEPHONE CALL JAKE FUSON
11/2/2015
11/2/2015
NOTIFIED JESUS PEREZ W/ ECO FRIENDLY ENERGY CO. (818 -
251-0752) THAT PLANS WERE APPROVED AND PERMIT WAS
READY TO ISSUE.
CONDITIONS
CONTACTS ----
NAME TYPE
NAME
NAME
ADDRESSI
CITY
STATE
ZIP PHONE
FAX
EMAIL
APPLICANT
ECO FRIENDLY ENERGY COMPANY
360 EAST FIRST STREET
STE #800
TUSTIN
CA
92780
JPEREZSADP@GMAIL.0
OM
CONTRACTOR
ECO FRIENDLY ENERGY COMPANY
360 EAST FIRST STREET
STE #800
1
TUSTIN
CA
1
92780
1 1OM
JPEREZSADP@GMAIL.0
OWNER
WAYNE MYERS
92253
Printed: Wednesday, November 04, 2015 10:54:10 AM 1 of 2
hTWSYSiEMS
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT#
CHECK#
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $0.00
BSA:
PV SYSTEM - ARRAY,
101-0000-42403
0
$24.17
$0.00
FIRST 20
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$0.00
FIRST 20 PC
PV SYSTEM - MISC
101-0000-42403
0
$24.17
$0.00
EQUIPMENT
PV SYSTEM - MISC
101-0000-426000
$24.17
$0.00
EQUIPMENT PC
Total Paid for ELECTRICAL: $96.68 $0.00
PERMIT ISSUANCE
101-0000-42404 1
0
$91.85
$0.00
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:• 00
Printed: Wednesday, November 04, 2015 10:54:10 AM 2 of 2
R?WSYS7EMS
Bin #
City of La Quinta
Building &r Safety Division
78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and. Tracking Sheet
Permit #
'56L- 'ZO
7
Project Address: Owner's Name:
110 )A 041 M-AP6
A. P. Number: 7j Do� Address-. qq3DD 04 tko 1>1
7 -
Legal Description: City, ST, Zip: V4 %AA44
Contractor: erp Tele phoneRle. 2,I)f4oft moo=
-J
'Address: i;•� T4 G,.M-e Z-0 0 Project Description: 4!!!.,0 1 eAl� 3�V
City, ST, Zip-. lk-Y;6P tA QT�W 1V\VA*&S
Telephone: W"J.;�L
,7
e
State Lic. 4: lnortjiT-7 City Lic. 9.:.
tacs;n S&V ct, Aq-7t, rod
Arch., Engr., Designer:
Address:
City., ST, Zip:
Tele phon,.� nstruction Type: Solay ov Occupancy:
. ...... ..
St -ate Lic. #: . ... ......... Add'n Alter Repair Demo
Project type (circle one<Tet
Name of Contac . t Person: Sq. Ft.: Vlzr To Units:
Telephone # of Contact Person: Q-7 45 a Estimated Value of Project: C ->O gn)
APPLICANT: DO NOT. WRITE BELOW THIS LINE
9
'Submittal
Req7d
Rcc1d
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance.
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2". Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.T.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE--
1rd. Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Fees
SITE PLAN
J9
SCOPE OF WORK
5.415 Kw, Roof Mount
{19) 285W Solar Wolyd Modules
19) Enphase Micro Inverters
(1) AC Disconnect
Lot Size: 123'x 83'
SHEET INDEX
PG 1 -SITE PLAN
PG 2 -ROOF PLAN
PG 3 -ONE LINE DIAGRAM
PG 4 -GENERAL NOTES
PG 5 - PLAC CARD SHEET
PG 6 -WIRE CALCS
- EQUIPMENT DATA SHEETS
& RELATED INFORMATION
CUSTOMER INFO
Wayne Myers
44300 Ocotillo Dr.
La -Quinta Ca 92253
THIS PROJECT SHALL COMPLY WITH
All construction shall comply with the 2013 California Building,
Residential, Mechanical, Elictrical, Plumbing, Energy and Green
Building Codes and the La Quinta Municipal Code.
0
0
0
17'
(e) Chimney
(n) 200A Main Service Panel
(n) AC Disconnect —
for conf r PE
structu
123'-
81
23'-8'
0
\ o
0
0
0
o
(n) Solar Panels
CONTRACTOR CONTACT INFORMATION
Eco Friendly Remodeling Li 1002357 Jesus Perez
360 E. First St. Suite 800 T5808.87116
Ca 92780 Phone: 818.251.0752
Phone: 888.577.6527 Fax: email: jperersadp@gmail.com
V1 M
4
N
W D
i alculations —
L. Lacher, R.C.E. 67656
of Engineering, Inc.
CITY OF LA QUI TA
(n) Solar Panels BUILDING & SAFETY EPT.
APPROVE
-- ----- 0R�ONSTRUCTI N
T
DATE 112 ij SY
(e)
35'
— (e) Patio Cover
(e) Solar Thermals
APN: 604.193.003
L(e) Pool
PG 1
83'
UN
J
Q
m
ROOF LAYOUT
NOTE. Poposed q/B pmt ehaH
be determined al
1- (N) 200A Main Service Panel
M 2- 285W Solar World Modules
G) 3- Enphase Micro Inverters
z 4- AC Disconnect
5- J -Box
6- 3/4 emt
ADDRESS
Wayne Myers
44300 Ocotillo Dr.
La Quinta Ca 92253
2,3
olar Thermals
ROOF DETAIL
2" x 4" 24" O.C.
4'
SYSTEM WEIGHT
ARRAY 342 SQ.FT.
SOLAR WORLD MODULES
3.1 LBS / SQ. FT.
RoofTrac tm.
CITY OF LA QUINTA
BUILDING & ST•
P
APPROVED
FOR CONSTRUCTION
DATE BY
6' MAX
ROOF STATTION
ANCHOR POINT
ANCHOR POINT
I ANCHOR POINT
5/16" stainless steel diameter lag screws @6' o.c.
with 3" penetration into existing framing member.
roof sealant at every penetration of the lagbolts
into roof framing.
24
.6LBS / SQ. FT. 2 x 4
TOTAL LBS / SQ. FT. 5/16" X 3 1/2°
3.7 LBS / SQ. FT. ss LAG
CONTRACTOR INI
Eco Friendly Remodel
360 E. First St. Suite
Phone: 888.577.6527
TIN CONTACT INFORMATION
1.11
1002357 Jesus Perez
Ca 92780 Phone: 818.251.0752
188.8716 email: iperersadpCcD-gmail.com
ALUMINUM RACKING
r�
S Tile Roof
72"
ANCHOR POINT
i
S Tile Roof
Post, can be installed r
through the top of
Habituate U. Seal
band
rail
~ — quick hook
3 Course Flashing
(mastci, tape, mastic
PG 2
ED
for conP P r nce to stru !jIlculations
Todd L. Lacher, R.C.E. 67656
P of Engineering, Inc.
SINGLE PHASE 120/240
MAIN/�f--- METER
SERVICE ( )
RATING CURRENT
9.2 A
[I
ilk
HC0313
25 A
POWER (@ 25'C)
285 W
—W
A
240
V
N
E1 ....... --
NEUTRAL
La Quinta Ca 92253
GROUNDING ELECTROO
PG 3
PV MODULE RATING @ STC
TUSTIN CA 92780
MODULE MFR
SOLAR WORLD
MODULE MODEL#
SW 285 W
OPEN CIRCUIT VOLTS
39.7 v
OPERATING VOLTS
31:3 v
RATING CURRENT
9.2 A
RT CIRCUIT CURRENT
9.84 A
SERIES FUSE (OCPO)
25 A
POWER (@ 25'C)
285 W
PV ARRAY INFORMATION
2 POLE 30 AMP PV
BACKFED CIRCUIT
BREAKER FURTHEST
AWAY FROM MAIN
(N) 200 AMP MAIN BREAKER (Bottom Fed)
(N) 200 AMP BUS BAR RATING
AC
i..............................I..
ONE LINE DIAGRAM
19 Solar Modules
(2)#10 AWG THWN '-Z
(1) #10 NUETRAL
(1) #8 GROUND
3/4" ENT
(N) 30 AMP Combiner
W/ (2) 1� AMP breakers
R
(4)#10 AWG THW N — Z
(1) #10 NUETRAL
(1) #8 GROUND
3/4" EMT
J -Box
note: All photoVoitalc system conductors Will be 90 degree C. rated
note:Provide a note on the plans stating that the AC disconnect Is a "Knife blade" type disconnect
RCE COMBINER RATINGS
: VALUES PER STRING:
RATING 30 A
RATING 240 V
INVERTER RATINGS
CONTRACTOR OF RECORD:
MAIN SERVICE
MAX DC VOLT RATING
48
V
MAX POWER @ 40-C
25Y
—W
NOMINALAC VOLTS
240
V
MAX AC CURRENT
1
A
CE SIGN ON DC I
ATING CURRENT
ATING VOLTS
SYS VOLTS
CIRCUIT CURRENT
NA A
NA v
NA v
NA A
CITY 05 LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
BARE #8 CONTINOUS
(9)sw 285 w
with (9) Enphase m250-60-2LL-522/523/s24 GROUND UNDER ARRAY
Istring#1) ON LUG FROM INVERTER
TO PANEL
Xsw 285 w
with (9) Enphase m250-60-2LL-522/523/s24
[string#2]
.............................................................................................................r
AC DISCONNECT RATINGS
CONTRACTOR OF RECORD:
MAIN SERVICE
DISCO AMP RATING
30
A
DISCO VOLT RATING
240
V
OCPD AMP RATING
30
A
OCPD VOLT RATING
240
V
SERVICE PANEL RATINGS #10 AWG FEEDERS 50 FEET
SERVICE VOLTS 240 V SYSTEM TYPE GROUNDED
MAIN OCPD AMP RATING 200 A
QTY OF MODULES IN SERIES 9 SOURCE CIRCUIT CONDUCTOR TYPE (OUTSIDE CONDUIT) USE -2 X PV WIRES X
QTY OF PARALLEL CIRCUITS 2.00 SOURCE CIRCUIT CONDUCTOR TYPE (INSIDE CONDUIT) THWN-2 X XHHW-2 RHW2; USE -2
SOURCE CIRCUIT CONDUCTOR SIZE ISEE NOTES FOR ARRAY WIRE 10 AWG
OCPD: OVER CURRENT PROTECTION IF CONDUIT TO RUN INSIDE TILDING IT WILL BE ENCASED IN METALLIC CONDUIT * MAX VOLTAGE WITH 22'F TEMP CORRECTION
SYSTEM SUMMARY
CONTRACTOR OF RECORD:
MAIN SERVICE
200 A
AZIMUTH
180/90 °
PV TILT
17 °
UNSHADED %
99 %
ROOF SLOPE
17
LEGAL OWNERS:
CONTRACTOR OF RECORD:
CONTACT INFORMATION:
SITE ADDRESS:
draftsman:
Wayne Myers
ECO FRIENDLY REMODELING 8 8 -6527
JESUS PEREZ
44300 Ocotillo Dr.
Jesus
360 E. FIRST ST.SUITE 800 C 0 57
818.251.0752
La Quinta Ca 92253
Perez
PG 3
TUSTIN CA 92780
1perersadp@gmail.com
GENERAL NOTES
* All field installed junction , pull and outlet boxes located behind modules or panels shall be accessible directly or by displacement
a module(s) or panel(s) secured by removable fasteners.
2010 California Residential Code (CRC) requires that Smoke alarms and
Carbon Monoxide alarms be retrofitted into the existing dwelling. These Smoke alarms are required
to be in all bedrooms, outside each bedroom, and at least one on each floor of the house. Carbon
Monoxide alarms are required to be retrofitted outside each bedroom and at least one on each floor
of the house. These alarms may be solely battery operated if the Photovoltaic project does not
involve the removal of interior wall and ceiling finishes inside the home, otherwise, the alarms must
be hard wired and interconnected.
' Provide a note stating that any conductors exposed to sunlight shall be listed as sunlight resistant,
(NEC 300.6 Cl, 310.8 D)
Where DC conductors are run inside the building (or attic), they shall be contained in a metal
raceway. (NEC 690.31 E)
' IID Will be noted prior to use and activiation of any solar system.
• System will be commissioned by owner per Interconnection Agreement.
' All exterior conduits will be 3/4 EMT, painted to match building with exterior primer and UV paint.
• All interior conductors will be labeled every 5 feet as: "Caution: DC Circuit".
' System will not be energized prior to IID approval.
• A ladder (or means to roof access) will be on site and placed for each inspection.
• The Solar PV system shall follow th State Fire Marshall Guideline (Cal Fire) in partnership with local fire department.
• Particular attention to access and pathway requirements (Cal Fire, local fire).
• Please note that adequate spacing must be maintained between any plumbing sewer vents extending
through the roof and the underside of the photovoltaic panels (6" minimum recommended).
• Attention to markings and labeling requirements on plaque detail page.
• Place reflective tape on the comers of all panels that intrude into hips or valleys that may cause a trip hazard to firefighters.
• Installation will comply with articles 250, 310, and 690 of 2013 CEC, CEC 310, and 690.
' Note on the plans that the photovoltaic inverter will be listed as UL 1741 compliant. (NEC 690.4 D)
• All exterior conduit, fittings, and boxes, shall be rain tight and approved for use in wet locations
• Please provide a note stating that the working clearances around the existing electrical equipment
as well as the new electrical equipment will be maintained in accordance with NEC 110.26
All metallic raceways and equipment shall be bonded and electrically continuous
manufacturers instructions, such that the roof covering shall serve to protect the building or structure CBC -1503.
• All components of the photovoltaic system are negatively grounded.
• In one and two family dwellings, live parts in PV source circuits and PV output circuits over 150 volts
to nrnund shall not he acc..essihle to nther than nualified nersnns while enerniied
* "Installers" of the equipment and wiring and interconnections shall be installed by "qualified persons" . NEC 690.4 E
* plumbing fixtures are to be retrofitted to comply with new requirements for water conservation. Toilets are to
be 1.28 gpf; single shower heads less than or equal to 2.0 gpm; residential lavatories to provide less than or
equal to 1.5gpm; and kitchen faucets to provide less than or equal to 1.8gpm; as required be Section 303.11
CallGreen and CA Civil Code 1101.1 et.Seq.
• Unless otherwise sapecified, not less than 30 inches in depth, Width, and
CONTRACTOR OF RECORD: A
height of working space and platform shall be provided to service
SITE ADDRESS:
mechanical appliances. No PV module shall encroach in this space, except sLDATE
UIN A
LAE t v
if the equipment listing is provided that shows the required clearance
D PT
around and above this unit may be less than required above UMC 305 andE:T
44300 Ocotillo Dr.
and NEC 110.26
UCTION
• Circuit breakers serving PV System to be legibly, durably, permanently and
360 E. FIRST ST.SUITE 800 LIC#
818.251.0752
La Quinta Ca 92253
indelibly marked CEC 110.12(3).
' The Solar PV system will be installed in accordance with article E90 of the NEC
TUSTIN CA 92780
' Grounding conductors smaller than #6 AWG must be protected from physical
damage by a raceway, cable armor or enclosure in protected hollow spaces
of Building Framing CEC 250.120 ( C ).
' All wiring materials shall be suitable for sun exposure and wet locations.
' Solar pv installation will not obstruct any plumbing, mechanical or building roof vents
' Roof coverings shall be designed, installed and maintained in accordance with both this code and approved
PV modules and associated equipment shall be protected from any physical damage.
each module shall be grounded using the supplied connection point identified on the
module and the manufactures instructions
• All components are UL listed and CEC certified where warranted.
' if the existing main service panel does not have a ground rod LIFER it is the PV
contractors responsibility to install a supplemental grounding electrode. In buildings
service grounding electrode must be verified at the time of inspection. Buildings
with a mettalic water pipe as the sole grounding electrode require a supplemental
electrode to be installed
• At point of disconnect a sign shall be mounted, "WARNING- ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION.
• signs shall be posted adjacent to each PV disconnect to indicate "PHOTOVOLTAIC
SYSTEM"
' Removal of a IID - interactive inverer or other equipment shall not disconnect the bonding connnection
between the grounding electrode conductor and the photovoltaic source and /or output circuit grounded conductor
LEGAL OWNERS:
CONTRACTOR OF RECORD: A
CONTACT INFORMATION:
SITE ADDRESS:
DRAWN BY:
Wayne Myers
ECO FRIENDLY REMODELING (888) 5 6
JESUS PEREZ
44300 Ocotillo Dr.
JESUS
360 E. FIRST ST.SUITE 800 LIC#
818.251.0752
La Quinta Ca 92253
PEREZ
PG 4
TUSTIN CA 92780
erersad mail.com
e '
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
........... ............................. .................... .._._.....------- ....._.... ....... ._----- .---- . ...... ... .......... .,....._..._ ..........
I;FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
I
r
2�3
711
11 t1�t "C�.7
2- feMir� MadkiP
B¢- , °f�°°°r act a
8- 3f4 amt
............ ......f................._............. 1-1.r—, ......... ............. .-.'.
PLAQUE SPECIFICATIONS:
a. Red background with white lettering
b. 3/8" letter height
c. All capital letters
d. Arial or similar font
e. Weather resistant material (i.e. enaraved clastic)
FAULT IS INDICATED, NORMALLY GROUNDED
CONCUCTORS MAY BE UNGROUNDED AND
ENERGIZED.
5" 1/4" LETTERING
PHOTOVOLTAIC POWER SOURCE RATING INVERTER
OPERATING CURRENT
19 A
MAX SYSTEM VOLTS
264 V
OPERATING VOLTS
240 V
SHORT CIRCUIT CURRENT
23.75 A
AT INVERTER
5"
WARNING
DC DISCONNECT
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE
AND LOAD SIDE MAY BE ENERGIZED
IN THE OFF POSITION
to
Remaining lettering = 3/8" AT DISCONNECTS
3" AT DISCONNECT
CAUTION: SOLAR t
CIRCUIT DISCONNECT FOR 1"
UTILITY OPERATION I 3/8" Lettering
to
WARNING ELECTRIC SHOCK HAZARD. THE DC
CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM AT EACH JUNCTION BOX
ARE UNGROUNDED AND MAY BE ENERGIZED.
WARNING INVERTER OUTPUT CONNECTION, DO
NOT RELOCATE THIS OVERCURRENT DEVICE. AT SOLAR BREAKER
3"
3"
FBUILDINGOF LA QUIP PA
�R®\/EDCONSTRUCTION
BY
�—
CAUTION SOLAR SYSTEM
CONNECTED AT MAIN SERVICE
FAUTION: SOLAR CIRCUIT AT JUNCTION BOXES
LEGAL OWNERS:
CONTRACTOR OF RECORD: 11k
CONTACT INFORMATION:
SITE ADDRESS:
DRAWN BY:
Wayne Myers
ECO FRIENDLY REMODELING 7 7
JESUS PEREZ
44300 Ocotillo Dr.
JESUS
l
360 E. FIRST ST.SUITE 800 LI
818.251.0752
La Quinta Ca 92253
PEREZ
PG 5
TUSTIN CA 92780 1
0 perersadp@gmaii.com
MODULE OPERATING CURRENT (IMPP) = 9.20 A
NUMBER OF STRINGS TO INVERTER = 1
INVERTER MAX INPUT CURRENT = 15 A
9.20A<15A,OK
MODULE OPERATING VOLTAGE (VMPP)= 31.3 V
NUMBER OF MODULES IN EACH STRING - 1
(1) 31.3 V = 31.3 V
INVERTER OPERATING INPUT RANGE= 16V - 48 V
MODULE VOC = 39.7 V
NUMBER OF MODULES IN EACH STRING = 1
(1)39.7=39.7V
VOLTAGE TEMPERATURE CORRECTION FACTOR = 1.12
39.7 V (1.12)= 44.46 V
INVERTER MAX INPUT VOLTAGE = 48V
44.46 V < 48V, OK
MODULE ISC = 9.84A
9.84 A (1.25)(1.25)=15.375 A (ISC)
MODULES SSERIES FUSE RATING = 25A
15.375 A < 25A, OK
NUMBER OF STRINGS TO INVERTER =1
(1) 9.84 A = 9.84 A
9.84 A (1.25)= 12.3 A
INVERTER OUTPUT CURRENT =1.OA
1.OA (19)(1.25)= 23.75 A [IC] USE (1) 30A BREAKER
SERVICE PANEL BUS RATING=(n)200 A
SERVICE PANEL MAIN OCPD = (n)200A
200A +(1) 30 A INVERTER OCPD = 230 A
200A BUS (1.2) = 240A
230A < 240A ok
A
WIRE CALCULATIONS
ON THE ROOF AND FROM JUNCTION BOX TO INVERTER:
EXPOSED TEMPERATURE = 29 C
TEMPERATURE ADDER FOR CONDUIT OFFSET FROM ROOF = 33 C
ADJUSTMENT FACTOR PER TABLE 310.16 FOR 90 C INSULATED CONDUCTOR AT 29 C + 33 C = 62 C = 0.58
r
SELECT WIRE SIZE WITH AMPACI I T GREATER THAN 23.86A, USE 10 AWG COPPER WIRE WITH AN AMPACITY OF 40A
BELOW THE ROOF AND FROM THE INVERTER TO MAIN PANEL
EXPOSED TEMPERATURE = 29 C ; -
ADJUSTMENT FACTOR PER TABLE 310.16 FOR 90 C INSULATED CONDUCTOR AT 29 C =1.00
IC = 20A
20.00A/1.00 = 20A
SELECT WIRE SIZE WITH AMPACITY GREATER THAN 20.00A, USE 10 AWG WIRE WITH AN AMPACITY OF 40A
CITY OF LA QUle 54
BUILDING & SAFETY DEPT.
APPROVE®
FOR CONSTRUCTION
DATE BY zir
LEGAL OWNERS:
CONTRACTOR OF RECORD:
CONTACT INFORMATION:
SITE ADDRESS;
DRAWN BY:
Wayne Myers
27
ECO FRIENDLY REMODELI:W3577
JESUS PEREZ
44300 Ocotillo Dr.
JESUS
360 E. FIRST ST.SUITE 800
818.251.0752
La Quinta Ca 92253
PEREZ
PG 6
TUSTIN CA 92780
iperersad mail.com