Loading...
BSOL2015-021178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tdy 4 s4P QuiKm COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSOL2015-0211 Property Address: 44300 OCOTILLO DR APN: 604193003 Application Description: MYERS/5.415kW PV SYSTEM Property Zoning: Application Valuation: $20,000.00 Applicant: c ' ECO FRIENDLY ENERGY COMPANY ' �F, 360 EAST FIRST STREET STE #800 TUSTIN, CA 92780 (19) PAN ELS/(19)MICROINV+200A MSP LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: A. B. C30, C46 License No.: 10012857 Date: 1 ! r 115Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (J) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's 37 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 (714)824-0047 Llc. No.: 1002357 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of a work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with thos provisions. Date: (S Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-ment ne property for inspection purposes. ; Date: (( Signature (Applicant or Agent): Date:., 11/4/2015 . r Owner: w WAYNE MYERS ,n mt 92253 c ' ' �F, Contractor:` ECO FRIENDLY ENERGY COMPANY 360 EAST FIRST STREET STE`MlOD- v TUSTIN, CA 92780 (714)824-0047 Llc. No.: 1002357 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of a work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with thos provisions. Date: (S Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend; indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-ment ne property for inspection purposes. ; Date: (( Signature (Applicant or Agent): DESCRIPTION FINANCIAL •• 1 ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL: $96.68 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY, METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 17. 0 0 0 `y OF Description: MYERS/5.415kW PV SYSTEM -(19) PANELS/(19)MICROINV+200A MSP Type: SOLAR Subtype: Status: APPROVED Applied: 10/22/2015 SGU Approved: 11/2/2015 JFU Parcel No: 604193003 Site Address: 44300 OCOTILLO DR LA QUINTA,CA 92253 Subdivision: TR 24517 Block: Lot: 63 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $20,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 NOTIFIED JESUS PEREZ W/ ECO FRIENDLY ENERGY CO. (818 - 251-0752) THAT PLANS WERE APPROVED AND PERMIT WAS READY TO ISSUE. Details: 5.415 kW SOLAR ARRAY - (19) 285W SOLARWORLD SW 285 MONO PANELS W/ (19) ENPHASE M250 MICROINVERTERS + MAIN SERVICE PANEL UPGRADE TO 200A [342SF] 2013 CALIFORNIA ELECTRICAL CODE. .-._,1 Applied to Approved Printed: Wednesday, November 04, 2015 10:54:10 AM 1 of 2 hTWSYSiEMS ADDITIONAL CHRONOLOGY TYPE STAFF NAME- CHRONOLOGY. ACTION DATE COMPLETION DATE NOTES TELEPHONE CALL JAKE FUSON 11/2/2015 11/2/2015 NOTIFIED JESUS PEREZ W/ ECO FRIENDLY ENERGY CO. (818 - 251-0752) THAT PLANS WERE APPROVED AND PERMIT WAS READY TO ISSUE. CONDITIONS CONTACTS ---- NAME TYPE NAME NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT ECO FRIENDLY ENERGY COMPANY 360 EAST FIRST STREET STE #800 TUSTIN CA 92780 JPEREZSADP@GMAIL.0 OM CONTRACTOR ECO FRIENDLY ENERGY COMPANY 360 EAST FIRST STREET STE #800 1 TUSTIN CA 1 92780 1 1OM JPEREZSADP@GMAIL.0 OWNER WAYNE MYERS 92253 Printed: Wednesday, November 04, 2015 10:54:10 AM 1 of 2 hTWSYSiEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT# CHECK# METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC PV SYSTEM - MISC 101-0000-42403 0 $24.17 $0.00 EQUIPMENT PV SYSTEM - MISC 101-0000-426000 $24.17 $0.00 EQUIPMENT PC Total Paid for ELECTRICAL: $96.68 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• 00 Printed: Wednesday, November 04, 2015 10:54:10 AM 2 of 2 R?WSYS7EMS Bin # City of La Quinta Building &r Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and. Tracking Sheet Permit # '56L- 'ZO 7 Project Address: Owner's Name: 110 )A 041 M-AP6 A. P. Number: 7j Do� Address-. qq3DD 04 tko 1>1 7 - Legal Description: City, ST, Zip: V4 %AA44 Contractor: erp Tele phoneRle. 2,I)f4oft moo= -J 'Address: i;•� T4 G,.M-e Z-0 0 Project Description: 4!!!.,0 1 eAl� 3�V City, ST, Zip-. lk-Y;6P tA QT�W 1V\VA*&S Telephone: W"J.;�L ,7 e State Lic. 4: lnortjiT-7 City Lic. 9.:. tacs;n S&V ct, Aq-7t, rod Arch., Engr., Designer: Address: City., ST, Zip: Tele phon,.� nstruction Type: Solay ov Occupancy: . ...... .. St -ate Lic. #: . ... ......... Add'n Alter Repair Demo Project type (circle one<Tet Name of Contac . t Person: Sq. Ft.: Vlzr To Units: Telephone # of Contact Person: Q-7 45 a Estimated Value of Project: C ->O gn) APPLICANT: DO NOT. WRITE BELOW THIS LINE 9 'Submittal Req7d Rcc1d TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2". Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.T. H.O.A. Approval Plans resubmitted Grading IN HOUSE-- 1rd. Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees SITE PLAN J9 SCOPE OF WORK 5.415 Kw, Roof Mount {19) 285W Solar Wolyd Modules 19) Enphase Micro Inverters (1) AC Disconnect Lot Size: 123'x 83' SHEET INDEX PG 1 -SITE PLAN PG 2 -ROOF PLAN PG 3 -ONE LINE DIAGRAM PG 4 -GENERAL NOTES PG 5 - PLAC CARD SHEET PG 6 -WIRE CALCS - EQUIPMENT DATA SHEETS & RELATED INFORMATION CUSTOMER INFO Wayne Myers 44300 Ocotillo Dr. La -Quinta Ca 92253 THIS PROJECT SHALL COMPLY WITH All construction shall comply with the 2013 California Building, Residential, Mechanical, Elictrical, Plumbing, Energy and Green Building Codes and the La Quinta Municipal Code. 0 0 0 17' (e) Chimney (n) 200A Main Service Panel (n) AC Disconnect — for conf r PE structu 123'- 81 23'-8' 0 \ o 0 0 0 o (n) Solar Panels CONTRACTOR CONTACT INFORMATION Eco Friendly Remodeling Li 1002357 Jesus Perez 360 E. First St. Suite 800 T5808.87116 Ca 92780 Phone: 818.251.0752 Phone: 888.577.6527 Fax: email: jperersadp@gmail.com V1 M 4 N W D i alculations — L. Lacher, R.C.E. 67656 of Engineering, Inc. CITY OF LA QUI TA (n) Solar Panels BUILDING & SAFETY EPT. APPROVE -- ----- 0R�ONSTRUCTI N T DATE 112 ij SY (e) 35' — (e) Patio Cover (e) Solar Thermals APN: 604.193.003 L(e) Pool PG 1 83' UN J Q m ROOF LAYOUT NOTE. Poposed q/B pmt ehaH be determined al 1- (N) 200A Main Service Panel M 2- 285W Solar World Modules G) 3- Enphase Micro Inverters z 4- AC Disconnect 5- J -Box 6- 3/4 emt ADDRESS Wayne Myers 44300 Ocotillo Dr. La Quinta Ca 92253 2,3 olar Thermals ROOF DETAIL 2" x 4" 24" O.C. 4' SYSTEM WEIGHT ARRAY 342 SQ.FT. SOLAR WORLD MODULES 3.1 LBS / SQ. FT. RoofTrac tm. CITY OF LA QUINTA BUILDING & ST• P APPROVED FOR CONSTRUCTION DATE BY 6' MAX ROOF STATTION ANCHOR POINT ANCHOR POINT I ANCHOR POINT 5/16" stainless steel diameter lag screws @6' o.c. with 3" penetration into existing framing member. roof sealant at every penetration of the lagbolts into roof framing. 24 .6LBS / SQ. FT. 2 x 4 TOTAL LBS / SQ. FT. 5/16" X 3 1/2° 3.7 LBS / SQ. FT. ss LAG CONTRACTOR INI Eco Friendly Remodel 360 E. First St. Suite Phone: 888.577.6527 TIN CONTACT INFORMATION 1.11 1002357 Jesus Perez Ca 92780 Phone: 818.251.0752 188.8716 email: iperersadpCcD-gmail.com ALUMINUM RACKING r� S Tile Roof 72" ANCHOR POINT i S Tile Roof Post, can be installed r through the top of Habituate U. Seal band rail ~ — quick hook 3 Course Flashing (mastci, tape, mastic PG 2 ED for conP P r nce to stru !jIlculations Todd L. Lacher, R.C.E. 67656 P of Engineering, Inc. SINGLE PHASE 120/240 MAIN/�f--- METER SERVICE ( ) RATING CURRENT 9.2 A [I ilk HC0313 25 A POWER (@ 25'C) 285 W —W A 240 V N E1 ....... -- NEUTRAL La Quinta Ca 92253 GROUNDING ELECTROO PG 3 PV MODULE RATING @ STC TUSTIN CA 92780 MODULE MFR SOLAR WORLD MODULE MODEL# SW 285 W OPEN CIRCUIT VOLTS 39.7 v OPERATING VOLTS 31:3 v RATING CURRENT 9.2 A RT CIRCUIT CURRENT 9.84 A SERIES FUSE (OCPO) 25 A POWER (@ 25'C) 285 W PV ARRAY INFORMATION 2 POLE 30 AMP PV BACKFED CIRCUIT BREAKER FURTHEST AWAY FROM MAIN (N) 200 AMP MAIN BREAKER (Bottom Fed) (N) 200 AMP BUS BAR RATING AC i..............................I.. ONE LINE DIAGRAM 19 Solar Modules (2)#10 AWG THWN '-Z (1) #10 NUETRAL (1) #8 GROUND 3/4" ENT (N) 30 AMP Combiner W/ (2) 1� AMP breakers R (4)#10 AWG THW N — Z (1) #10 NUETRAL (1) #8 GROUND 3/4" EMT J -Box note: All photoVoitalc system conductors Will be 90 degree C. rated note:Provide a note on the plans stating that the AC disconnect Is a "Knife blade" type disconnect RCE COMBINER RATINGS : VALUES PER STRING: RATING 30 A RATING 240 V INVERTER RATINGS CONTRACTOR OF RECORD: MAIN SERVICE MAX DC VOLT RATING 48 V MAX POWER @ 40-C 25Y —W NOMINALAC VOLTS 240 V MAX AC CURRENT 1 A CE SIGN ON DC I ATING CURRENT ATING VOLTS SYS VOLTS CIRCUIT CURRENT NA A NA v NA v NA A CITY 05 LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY BARE #8 CONTINOUS (9)sw 285 w with (9) Enphase m250-60-2LL-522/523/s24 GROUND UNDER ARRAY Istring#1) ON LUG FROM INVERTER TO PANEL Xsw 285 w with (9) Enphase m250-60-2LL-522/523/s24 [string#2] .............................................................................................................r AC DISCONNECT RATINGS CONTRACTOR OF RECORD: MAIN SERVICE DISCO AMP RATING 30 A DISCO VOLT RATING 240 V OCPD AMP RATING 30 A OCPD VOLT RATING 240 V SERVICE PANEL RATINGS #10 AWG FEEDERS 50 FEET SERVICE VOLTS 240 V SYSTEM TYPE GROUNDED MAIN OCPD AMP RATING 200 A QTY OF MODULES IN SERIES 9 SOURCE CIRCUIT CONDUCTOR TYPE (OUTSIDE CONDUIT) USE -2 X PV WIRES X QTY OF PARALLEL CIRCUITS 2.00 SOURCE CIRCUIT CONDUCTOR TYPE (INSIDE CONDUIT) THWN-2 X XHHW-2 RHW2; USE -2 SOURCE CIRCUIT CONDUCTOR SIZE ISEE NOTES FOR ARRAY WIRE 10 AWG OCPD: OVER CURRENT PROTECTION IF CONDUIT TO RUN INSIDE TILDING IT WILL BE ENCASED IN METALLIC CONDUIT * MAX VOLTAGE WITH 22'F TEMP CORRECTION SYSTEM SUMMARY CONTRACTOR OF RECORD: MAIN SERVICE 200 A AZIMUTH 180/90 ° PV TILT 17 ° UNSHADED % 99 % ROOF SLOPE 17 LEGAL OWNERS: CONTRACTOR OF RECORD: CONTACT INFORMATION: SITE ADDRESS: draftsman: Wayne Myers ECO FRIENDLY REMODELING 8 8 -6527 JESUS PEREZ 44300 Ocotillo Dr. Jesus 360 E. FIRST ST.SUITE 800 C 0 57 818.251.0752 La Quinta Ca 92253 Perez PG 3 TUSTIN CA 92780 1perersadp@gmail.com GENERAL NOTES * All field installed junction , pull and outlet boxes located behind modules or panels shall be accessible directly or by displacement a module(s) or panel(s) secured by removable fasteners. 2010 California Residential Code (CRC) requires that Smoke alarms and Carbon Monoxide alarms be retrofitted into the existing dwelling. These Smoke alarms are required to be in all bedrooms, outside each bedroom, and at least one on each floor of the house. Carbon Monoxide alarms are required to be retrofitted outside each bedroom and at least one on each floor of the house. These alarms may be solely battery operated if the Photovoltaic project does not involve the removal of interior wall and ceiling finishes inside the home, otherwise, the alarms must be hard wired and interconnected. ' Provide a note stating that any conductors exposed to sunlight shall be listed as sunlight resistant, (NEC 300.6 Cl, 310.8 D) Where DC conductors are run inside the building (or attic), they shall be contained in a metal raceway. (NEC 690.31 E) ' IID Will be noted prior to use and activiation of any solar system. • System will be commissioned by owner per Interconnection Agreement. ' All exterior conduits will be 3/4 EMT, painted to match building with exterior primer and UV paint. • All interior conductors will be labeled every 5 feet as: "Caution: DC Circuit". ' System will not be energized prior to IID approval. • A ladder (or means to roof access) will be on site and placed for each inspection. • The Solar PV system shall follow th State Fire Marshall Guideline (Cal Fire) in partnership with local fire department. • Particular attention to access and pathway requirements (Cal Fire, local fire). • Please note that adequate spacing must be maintained between any plumbing sewer vents extending through the roof and the underside of the photovoltaic panels (6" minimum recommended). • Attention to markings and labeling requirements on plaque detail page. • Place reflective tape on the comers of all panels that intrude into hips or valleys that may cause a trip hazard to firefighters. • Installation will comply with articles 250, 310, and 690 of 2013 CEC, CEC 310, and 690. ' Note on the plans that the photovoltaic inverter will be listed as UL 1741 compliant. (NEC 690.4 D) • All exterior conduit, fittings, and boxes, shall be rain tight and approved for use in wet locations • Please provide a note stating that the working clearances around the existing electrical equipment as well as the new electrical equipment will be maintained in accordance with NEC 110.26 All metallic raceways and equipment shall be bonded and electrically continuous manufacturers instructions, such that the roof covering shall serve to protect the building or structure CBC -1503. • All components of the photovoltaic system are negatively grounded. • In one and two family dwellings, live parts in PV source circuits and PV output circuits over 150 volts to nrnund shall not he acc..essihle to nther than nualified nersnns while enerniied * "Installers" of the equipment and wiring and interconnections shall be installed by "qualified persons" . NEC 690.4 E * plumbing fixtures are to be retrofitted to comply with new requirements for water conservation. Toilets are to be 1.28 gpf; single shower heads less than or equal to 2.0 gpm; residential lavatories to provide less than or equal to 1.5gpm; and kitchen faucets to provide less than or equal to 1.8gpm; as required be Section 303.11 CallGreen and CA Civil Code 1101.1 et.Seq. • Unless otherwise sapecified, not less than 30 inches in depth, Width, and CONTRACTOR OF RECORD: A height of working space and platform shall be provided to service SITE ADDRESS: mechanical appliances. No PV module shall encroach in this space, except sLDATE UIN A LAE t v if the equipment listing is provided that shows the required clearance D PT around and above this unit may be less than required above UMC 305 andE:T 44300 Ocotillo Dr. and NEC 110.26 UCTION • Circuit breakers serving PV System to be legibly, durably, permanently and 360 E. FIRST ST.SUITE 800 LIC# 818.251.0752 La Quinta Ca 92253 indelibly marked CEC 110.12(3). ' The Solar PV system will be installed in accordance with article E90 of the NEC TUSTIN CA 92780 ' Grounding conductors smaller than #6 AWG must be protected from physical damage by a raceway, cable armor or enclosure in protected hollow spaces of Building Framing CEC 250.120 ( C ). ' All wiring materials shall be suitable for sun exposure and wet locations. ' Solar pv installation will not obstruct any plumbing, mechanical or building roof vents ' Roof coverings shall be designed, installed and maintained in accordance with both this code and approved PV modules and associated equipment shall be protected from any physical damage. each module shall be grounded using the supplied connection point identified on the module and the manufactures instructions • All components are UL listed and CEC certified where warranted. ' if the existing main service panel does not have a ground rod LIFER it is the PV contractors responsibility to install a supplemental grounding electrode. In buildings service grounding electrode must be verified at the time of inspection. Buildings with a mettalic water pipe as the sole grounding electrode require a supplemental electrode to be installed • At point of disconnect a sign shall be mounted, "WARNING- ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. • signs shall be posted adjacent to each PV disconnect to indicate "PHOTOVOLTAIC SYSTEM" ' Removal of a IID - interactive inverer or other equipment shall not disconnect the bonding connnection between the grounding electrode conductor and the photovoltaic source and /or output circuit grounded conductor LEGAL OWNERS: CONTRACTOR OF RECORD: A CONTACT INFORMATION: SITE ADDRESS: DRAWN BY: Wayne Myers ECO FRIENDLY REMODELING (888) 5 6 JESUS PEREZ 44300 Ocotillo Dr. JESUS 360 E. FIRST ST.SUITE 800 LIC# 818.251.0752 La Quinta Ca 92253 PEREZ PG 4 TUSTIN CA 92780 erersad mail.com e ' CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE ........... ............................. .................... .._._.....------- ....._.... ....... ._----- .---- . ...... ... .......... .,....._..._ .......... I;FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN I r 2�3 711 11 t1�t "C�.7 2- feMir� MadkiP B¢- , °f�°°°r act a 8- 3f4 amt ............ ......f................._............. 1-1.r—, ......... ............. .-.'. PLAQUE SPECIFICATIONS: a. Red background with white lettering b. 3/8" letter height c. All capital letters d. Arial or similar font e. Weather resistant material (i.e. enaraved clastic) FAULT IS INDICATED, NORMALLY GROUNDED CONCUCTORS MAY BE UNGROUNDED AND ENERGIZED. 5" 1/4" LETTERING PHOTOVOLTAIC POWER SOURCE RATING INVERTER OPERATING CURRENT 19 A MAX SYSTEM VOLTS 264 V OPERATING VOLTS 240 V SHORT CIRCUIT CURRENT 23.75 A AT INVERTER 5" WARNING DC DISCONNECT ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OFF POSITION to Remaining lettering = 3/8" AT DISCONNECTS 3" AT DISCONNECT CAUTION: SOLAR t CIRCUIT DISCONNECT FOR 1" UTILITY OPERATION I 3/8" Lettering to WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM AT EACH JUNCTION BOX ARE UNGROUNDED AND MAY BE ENERGIZED. WARNING INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE. AT SOLAR BREAKER 3" 3" FBUILDINGOF LA QUIP PA �R®\/EDCONSTRUCTION BY �— CAUTION SOLAR SYSTEM CONNECTED AT MAIN SERVICE FAUTION: SOLAR CIRCUIT AT JUNCTION BOXES LEGAL OWNERS: CONTRACTOR OF RECORD: 11k CONTACT INFORMATION: SITE ADDRESS: DRAWN BY: Wayne Myers ECO FRIENDLY REMODELING 7 7 JESUS PEREZ 44300 Ocotillo Dr. JESUS l 360 E. FIRST ST.SUITE 800 LI 818.251.0752 La Quinta Ca 92253 PEREZ PG 5 TUSTIN CA 92780 1 0 perersadp@gmaii.com MODULE OPERATING CURRENT (IMPP) = 9.20 A NUMBER OF STRINGS TO INVERTER = 1 INVERTER MAX INPUT CURRENT = 15 A 9.20A<15A,OK MODULE OPERATING VOLTAGE (VMPP)= 31.3 V NUMBER OF MODULES IN EACH STRING - 1 (1) 31.3 V = 31.3 V INVERTER OPERATING INPUT RANGE= 16V - 48 V MODULE VOC = 39.7 V NUMBER OF MODULES IN EACH STRING = 1 (1)39.7=39.7V VOLTAGE TEMPERATURE CORRECTION FACTOR = 1.12 39.7 V (1.12)= 44.46 V INVERTER MAX INPUT VOLTAGE = 48V 44.46 V < 48V, OK MODULE ISC = 9.84A 9.84 A (1.25)(1.25)=15.375 A (ISC) MODULES SSERIES FUSE RATING = 25A 15.375 A < 25A, OK NUMBER OF STRINGS TO INVERTER =1 (1) 9.84 A = 9.84 A 9.84 A (1.25)= 12.3 A INVERTER OUTPUT CURRENT =1.OA 1.OA (19)(1.25)= 23.75 A [IC] USE (1) 30A BREAKER SERVICE PANEL BUS RATING=(n)200 A SERVICE PANEL MAIN OCPD = (n)200A 200A +(1) 30 A INVERTER OCPD = 230 A 200A BUS (1.2) = 240A 230A < 240A ok A WIRE CALCULATIONS ON THE ROOF AND FROM JUNCTION BOX TO INVERTER: EXPOSED TEMPERATURE = 29 C TEMPERATURE ADDER FOR CONDUIT OFFSET FROM ROOF = 33 C ADJUSTMENT FACTOR PER TABLE 310.16 FOR 90 C INSULATED CONDUCTOR AT 29 C + 33 C = 62 C = 0.58 r SELECT WIRE SIZE WITH AMPACI I T GREATER THAN 23.86A, USE 10 AWG COPPER WIRE WITH AN AMPACITY OF 40A BELOW THE ROOF AND FROM THE INVERTER TO MAIN PANEL EXPOSED TEMPERATURE = 29 C ; - ADJUSTMENT FACTOR PER TABLE 310.16 FOR 90 C INSULATED CONDUCTOR AT 29 C =1.00 IC = 20A 20.00A/1.00 = 20A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 20.00A, USE 10 AWG WIRE WITH AN AMPACITY OF 40A CITY OF LA QUle 54 BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATE BY zir LEGAL OWNERS: CONTRACTOR OF RECORD: CONTACT INFORMATION: SITE ADDRESS; DRAWN BY: Wayne Myers 27 ECO FRIENDLY REMODELI:W3577 JESUS PEREZ 44300 Ocotillo Dr. JESUS 360 E. FIRST ST.SUITE 800 818.251.0752 La Quinta Ca 92253 PEREZ PG 6 TUSTIN CA 92780 iperersad mail.com