Loading...
BRES2015-0359{ t: • I I'll" IIIII lilt llll 36 78-495 CALLE TAMPICO I 1 "�� VOICE (760) 777-7125 �` FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUN -'EVELOPIVIENT DEPARTM INSPECTIONS (760) 777-7153 UILDINGSERMbf Z�15 U Date: 11/9/2015 Application Number: BRES2015-0359 v� �F Lk(al)�NTA Property Address: 79935 RANCHO LA QUINTA DR okVELOPME�T�EPAR� Di SYDNEYTULS APN: 602220014 Y 79935 RANCHO LA QUINTA DR Application Description: TULS RESIDENCE/ GARAGE EXTENSION LA QUINTA, CA 92253 Property Zoning: Application Valuation: $4,116.00 Applicant: Contractor: JORGE GARCIA SANTUCCI BUILDERS INC 72529 BEAVERTAIL 72529 BEAVERTAIL STREET PALM DESERT, CA 92260 PALM DESERT, CA 92260 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class/fi__j Class/B__License No.: 820801 Date: 1 (Contractor." OWNER -BUIL DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the c basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's (760)578-7757 Llc. No.: 820801 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with o�-�,omwwAocilicant­;*_ rovisions. Dater � WARNING: FYLURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnity and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and he eby authorize representatives of this city to enter upon the above-metn/tiio ed p o`perty for inspection purposes. D.at�v"ti1 C Signature-(Applicant-or_Agent):— _ ` � SDESC IPT N2k` ACCOUNT a AMOUNT PAID P IA DADA E . .k "° ..w , s Y ' Psi ,r 7, . Q� HOURLY PLAN CHECK - YES 101-0000-42600 1.25 $87.50 '$81.50 ' 11/9/15 M HOD RECEI T # > CHECKS #" C T BY � SANTUCCI BUILDERS INC CHECK. R10696 7514 MFA ON �`fiDESCRIPTION ACO NTS QTaY, NT PAIf) P DSA E. �cfLh3• o(6'SLd3k+;o:6'A"1'vRti�_., Sr'. d„. .'!�'.� N,i-/av+�4�xxs�fl.'l'i6*d'v'. e.AA�I�V.vI Dv .:,,Yl'Jf�:VXF -:^.%r HOURLY PLAN CHECK -YES 101-0000-42600 1. • $70.00 $70.00 _11/9/15 ����' sMETHOO �N RECE .T�# C CK # CLTDBY" ���PAIDBY� �' _ �� E � SANTUCCI BUILDERS INC CHECK R10696 7514 MFA Total Paid for BLDG CITY STAFF -PER HOUR:. $157.50 $157.50 'f)ESCRIPT ON ACCO NT QTY 2X A OyUNT P p PAID A E ..(.+'i.?fx -k', a,.ta «$.;'�52:"}.i' .s R "8£."xAYi..4:+io._ X's:4`e�}£X� BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 11/9/15 PAID3Y METFIOD: CHECK # CL�TD BY� Jiy'i '. *n ', - 5� SQ�A.G$Rv w-EIPT 5.,�1�31fiC `*,lk .,L- 1 R.�', SANTUCCI BUILDERS INC CHECK R10696 7514 MFA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:. $1.00', $1.00 r " s aDESCRIPTIONz - . ` S ' ACCUNT .: MOUNTS .: P.,AID "PAID A E ,0�� RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 - $145.03. $145:03 11/9/15 PAIf) BY x�, Y - N METH —D:-'! RE E PT W, CIiECKxZ# � � CLTD BY 5, k�, , ...w' I.SX+:ffiWY79.'%S4stA4c"xa.'h+,d. '.i.,. :3tttde.. /a'' fi4"`."k+vh. SANTUCCI BUILDERS INC CHECK .. R10696 7514 MFA , DESCRIPTION ACCOUNT ' ' QTY;k�AINIOUNT0 ° PAID fr DDATE SLK`c`P.F.>_'.+'h'.7?.... L'v v4,L �:afi �i25K^X::. RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86' $47.86 11/9/15 ..,s''x 'Z %x Y -i AID 8 o) 'OiY,�fr ,vS .x�,ay Y% AMET OD fY, Sz% t`Kr " �x,�£RECEIPT # CIiECK # Fi.CS.s'.'S k UT BY . j:. SANTUCCI BUILDERS INC CHECK R10696 .7514 MFA Total Paid,for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 ` $ ;`� ACCU.UNTR� PAI r? k ,cDESCRIP�TION a r . ANT sADeO NEW.CONSTRUCTION PERMIT 101-0000-42400 0 $181.30 $181.30 11/9/15 r. " PAID BY�3 MHOD RECEIPT# CHECK �CLTD BY F , SANTUCCI BUILDERS INC CHECK R10696 7514 MFA Total Paid for NEW CONSTRUCTIONPERMIT: ti' $181.30 $181.30 y'DESCRIPTION ACCOUN Q�x TY� AMO NT PA D PARD DATE 1A`k.t .# :3 'krXX.c. .�*r.�. ''Sss... - NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $274.65 $274.6S` 11/9/15 '�pPAID BY�s �METIIOD REGEIPT�# CHECK# �L D BY z. SANTUCCI BUILDERS INC CHECK R30696. 7514. MFA Total Paid .for NEW CONSTRUCTION PLAN CHECK: $274:65 $274.65 ,r 'a ACCOUNT��TY C,(! " AMOUNT PAID PAIUDATE SMI - RESIDENTIAL 101-0000-20308 0 $0:54 $0.54 11/9/15, - gam' �`, BY� '. rzi€ &� i METHOD '' " �.��k''>"` RECEIPTS# CHECK # �CITD BY;. �$:&�.s�'.3:' sPAID z ,"• vaa+' n..*.TA.`. va"?! b'..ry iLU3n/.b;`.: 3 ..--,?Y+X�.?:�, SANTUCCI BUILDERS INC- CHECK R10696 7514 MFA Total Paid for STRONG MOTION INSTRUMENTATION SMI:,, $0.54 $0.54 Permit Details PERMIT NUMBER City of La Quinta BRES20115=0359 Description: TULS RESIDENCE / GARAGE EXTENSION Type: BUILDING, RESIDENTIAL Subtype: GARAGE Status: ISSUED Applied: 9/16/2015 MFA Approved: 11/6/2015 JJO Parcel No: 602220014 Site Address: 79935 RANCHO LA QUINTA DR LA QUINTA,CA 92253 Subdivision: TR 29457-1 Block: Lot: 34 Issued: 11/9/2015 MFA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,116.00 Occupancy Type: Construction Type: Expired: 5/7/2016 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 NOTE Details: ADDITION TO EXISTING GAREGE 210 SQ. FT. PER 2013 CRC GODES 11/3/2015 51 3 Applied to Approved' Approved to Issued Printed: Monday, November 09, 2015 12:30:52 PM 1 of 4MAN q SYSTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JIM JOHNSON 9/29/2015 10/2/2015 NOTE JIM JOHNSON 11/3/2015 11/6/2015 PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 10/2/2015 10/2/2015 STRUC NOT APPROVABLE RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 11/6/2015 11/6/2015 STRUC APPROVABLE 11/5/2015 RECEIVED PLAN CHECK PICKED UP AJ ORTEGA 10/21/2015 10/21/2015 PICKED UP BY JERRY SANTUCCIO PLAN CHECK SENT TO MARY FASANO 9/16/2015 9/16/2015 OUTSIDE PC PLAN CHECK SENT TO STEPHANIE GUMPERT 10/26/2015 10/26/2015 SENT TO YOUNG. DUE BACK 11/09/15 OUTSIDE PC Printed: Monday, November 09, 2015 12:30:52 PM 1 of 4MAN q SYSTEMS PLAN CHECK SUBMITTAL MARY FASANO 9/16/2015 9/16/2015 RECEIVED FINANCIAL•• PLAN CHECK SUBMITTAL STEPHANIE GUMPERT 10/26/2015 10/26/2015 RECEIVED CLTD DESCRIPTION ACCOUNT TELEPHONE CALL AMOUNT JIM JOHNSON 9/29/2015 RECEIPT # 9/29/2015 METHOD CALLED JERRY TO INFORM HIM I NEED A HOA LETTER TELEPHONE CALL JIM JOHNSON 10/2/2015 10/2/2015 called jerry to inform him plans are ready for corrections BY HOURLY PLAN CHECK - 101-0000-42600 1.25 CALLED JORGE GARCIA TO INFORM HIM PLANS ARE READY TELEPHONE CALL 11/9/15 JIM JOHNSON 11/6/2015 CHECK 11/6/2015 MFA YES TO ISSUE INC HOURLY PLAN CHECK - CONDITIONS 1 $70.00 $70.00 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA YES CONTACTS NAME TYPE NAME ADDRESSI CITY 'STATE ZIP PHONE FAX EMAIL APPLICANT R10696 JORGE GARCIA 72529 BEAVERTAIL PALM DESERT CA 92260 CONTRACTOR SANTUCCI BUILDERS INC 72529 BEAVERTAIL PALM DESERT CA 92260 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: STREET OWNER JUDY & SYDNEY TULS 79935 RANCHO LA LA QUINTA CA 92253 QUINTA DR Printed: Monday, November 09, 2015 12:30:52 PM 2 of 4 CJ? SYSTEh1S FINANCIAL•• • CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY HOURLY PLAN CHECK - 101-0000-42600 1.25 $87.50 $87.50 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA YES INC HOURLY PLAN CHECK - 101-0000-42600 1 $70.00 $70.00 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA YES INC Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $157.50 BSAS SB1473 FEE 101-0000-20306 7 0 $1.00 $1.00 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: Printed: Monday, November 09, 2015 12:30:52 PM 2 of 4 CJ? SYSTEh1S Permit Details PERMIT NUMBER E City of La Quinta BRES2015=0359 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES FINAL" BLD REVIEWS REVIEW TYPE REVIEWER TL D DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY 1ST BLDG NS (2 WK) JIM JOHNSON 9/16/2015 9/30/2015 9/29/2015 APPROVED BY RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA 1,OOOSF INC RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA 1,000SF, PC INC Total Paid for'ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 NEW CONSTRUCTION 101-0000-42400 0 $181.30 $181.30 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA PERMIT INC Total Paid for NEW CONSTRUCTION PERMIT: $181.30 $181.30 NEW CONSTRUCTION 101-0000-426000 $274.65 $274.65 11/9/15 R10696 7514 CHECK SANTUCCI BUILDERS MFA PLAN CHECK INC Total Paid for NEW CONSTRUCTION PLAN CHECK: $274.65 $274.65 SMI - RESIDENTIAL 101-0000-20308 0 $0.54 $0.54 11/9/15 R10696 7514 CHECK SANTUCCIINCUILDERS MFA Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.54 $0.54 $807.88 $807.88 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES FINAL" BLD Printed: Monday, November 09, 2015 12:30:52 PM 3 of 4 RIffsysrrnns REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES,,. DATE 1ST BLDG NS (2 WK) JIM JOHNSON 9/16/2015 9/30/2015 9/29/2015 APPROVED 1ST BLDG STR (2 YOUNG 9/16/2015 9/30/2015 10/1/2015 REVISIONS REQUIRED . WK) ENGINEERING Printed: Monday, November 09, 2015 12:30:52 PM 3 of 4 RIffsysrrnns 2ND BLDG NS (2 WK) JIM JOHNSON 10/26/2015 11/9/2015 11/3/2015 APPROVED -' CREATED OWNER : ; .DESCRIPTION - PATHNAME 2ND BLDG STR (2 YOUNG 10/26/2015 -11/9/2015 11/5/2015 READY FOR APPROVAL NEW CITY WK) ENGINEERING 10/1/2015 KATHRYN SAMUELS 1ST REVIEW - TRANSMITTAL BRES 0 RONn INFORMATInN Printed: Monday, November 09, 2015 12:30:52 PM 4 of 4 IVEY SYSTEMS ATTACHMENTS $ Attachment Type -' CREATED OWNER : ; .DESCRIPTION - PATHNAME SUBDIR ETRAKIT ENABLED` NEW CITY DOC 10/1/2015 KATHRYN SAMUELS 1ST REVIEW - TRANSMITTAL BRES 0 STRUCTURAL REVIEW 2015-0359 (lst).pdf NEW CITY DOC 11/5/2015 KATHRYN SAMUELS 2ND REVIEW - TRANSMITTAL BRES 0 STRUCTURAL REVIEW 2015-0359 (2nd).pdf Printed: Monday, November 09, 2015 12:30:52 PM 4 of 4 IVEY SYSTEMS in,, a 9 Bin #5 City of La Quinta 'r Safety Division Building & P.O. Box 1504, 78-495 Calle Tampico Cl La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # &rLCp-0 K Project Address: 35Vw("o Lmogm RvE Owner's Name: Ajpkgq A. P. Number: Address: � qqlv.A DR - Legal Description: City, ST, Zip: I-zz Contractor: Telephone: Address: Project Description: City, ST, Zip-. NA CIN qUV3 (P�t WmEgslw (2(0,s.f) Telephone: 100 - State Lic.#: City Lie, #.-.. Arch., Engr.,(esigne), Address: 4&-rs M Err. F. City, ST, Zip: F44A D� ', Telephone: Construction Type: Occupancy: State Project type (circle one): New dd' Alter Repair Demo Name of Contact Person: Sq. Ft.: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural CaIcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 211 Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Re.yiew, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Master Association for Rancho La Quinta 79-285 Rancho La Quinta Drive - La Quinta CA 92253 Phone: 760-777-8807 Fax: 760-777-8961 www.rlqma.com Date: October 21, 2015 Sidney & Judy.+Tuls 79935 Rancho La Quinta Dr La Quinta CA 92253 Re: 79935 Rancho La Quinta Driv - Approval of Submission Dear Mr. & Mrs. Tuls, The Architectural Committee reviewed your submission for the following improvements: Extend garage 10' toward street, remove sliding door at rear patio and replace with stacking door, install pavers (Belgard "Montecito Blend" with Catina 4 piece style) in rear yard, front entry and driveway, install new fire pit and barbeque. Your submission as presented, is approved contingent on the following; • Any damage to the common area caused during this construction shall be repaired by the Owner to the satisfaction of the Association. • All work is to be done in accordance with all applicable requirements of governmental entities, including the City of La Quinta and in accordance with all Homeowners Association Architectural/Landscape Guidelines and governing documents. • If required, a City of La Quinta building permit will be obtained and copy furnished to the. Association prior to commencement of work. • Roof tiles on new construction shall match existing roof tiles in both style and color. • No other structural changes are approved with this submission. Once completed, please submit a "Notice of Completion" and the Association's Architect will schedule an inspection so we can process your deposit for return. If you have any questions, please contact the onsite office at 760-777-8807. � . Jamie e , Architectural & Communications Manager Master Association for Rancho La Quinta •� F • �Ii�rl�liiti COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/2/2015 STATUS: FIRST REVIEW PLAN CHECKED BY: JIM JOHNSON TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 79-935 RANCHO LA QUINTA DESCRIPTION: GARAGE ADDITION APPLICANT: TULS PLAN CHECK #: BRES2015-0359 This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 2 SETS OF PLANS ASSESSORS SET 2 SETS STRUC CALCS THIS CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: REDLR4ED SETS 2 NEW REVISED SETS 2 SETS TRUSS CALCS 2 STES STRUC CALCS THIS CORRECTION LIST / RESPONSES INSTRUCTIONS TO APPLICANT: OCT 2 6 2015 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC CSe�ftrtlQ03Q&bIT& acceptable. Show or note specifically how compliance with a code requi p ogp-p iiel-, IRZw8naT such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Pagel of 2 SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536. Resubmittals will not be accepted with signatures missing. SECTION I - STRUCTURAL 1) See separate structural correction list, attached. Important note to Engineer of Record: If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include: • One complete set of structural calculations from the previous submittal, and... • Two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose pages will not be assembled by the Building Department. Important note: If manufactured truss products are used on this project, be aware that the City of La Quinta does not allow deferred submittals. Truss calculations are required no later than the second submittal. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide letter of approval from Homeowners' Association. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2 City of La Quinta Building and Safety Department Plan Check Corrections 5tru ural Tuls Residence — Garage Addition 79935 Rancho La Quinta Drive La Quinta, California Engineer: Reza Asgharpour, P.E. Plan Check No.: BRES 2015-0359 (1" check) Date: 10/1/15 1. Truss calculations for metal plate connected wood trusses may not be a deferred submittal. Provide truss calculations with resubmittal. The Engineer of Record shall issue a letter of review and approval to the Building official or affix a shop drawing stamp on the truss calculations stating reviewed and accepted. If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations from this submittal plus two complete, bound copies of the revised calculations for review and approval. Providing only a few supplemental, revised pages will not be accepted and will delay approval of this project. Return all redlined structural plans and calculations at resubmittal. Please incorporate requested corrections into plan sets and reprint. Plan Reviewer: Kathryn Samuels Phone No.: 760-772-5107 R E C" F., I E D OCT 01 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and, Professions Code §5536. Resubmittals will not be accepted with signatures missing. SECTION I - STRUCTURAL 1) See separate structural correction list, attached. Important note to Engineer of Record: If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include: • One complete set of structural calculations from the previous submittal, and... • Two complete, stamped and wet -signed sets of structural calculations for review and approval: Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client''s project. Incomplete sets, loose pages will not be assembled by the Building Department. Important note: If manufactured truss products are used on this project, be aware that the City of La Quinta does not allow deferred submittals. Truss calculations are required no later than the second submittal. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. JV 2) Provide letter of approval from Homeowners' Association. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2 f City of La 'Quinta Building and Safety Department Plan Check Corrections ` 5f�u`� ctura�l. Tuls Residence — Garage Addition 79935 Rancho La Quinta Drive La Quinta, California Engineer: Reza Asgharpour, P.E. Plan Check No.: BRES 2015-0359 (15t check) Date: 10/1/15 1. Truss calculations for metal plate connected wood trusses may not be a deferred submittal. Provide truss calculations with resubmittal. The Engineer of Record shall issue a letter of review and approval to the Building official or affix a shop drawing stamp on the truss calculations stating reviewed and accepted. If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations from this submittal plus two complete, bound copies of the revised calculations for review and approval. Providing only a few supplemental, revised pages will not be accepted and will delay approval of this project. Return all redlined structural plans and calculations at resubmittal. Please incorporate requested corrections into plan sets and reprint. Plan Reviewer: Kathryn Samuels Phone No.: 760-772-5107 Y 0 C T 0 1 2.015 CITY OF Ui QUINTI; COMMUNITY DEVELOPMENT T46f a( 6(4Paabrw P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CAL4FORNIA 92253 FAX (760) 777-701 1 TRANSMITTAL TO: VOUNG ❑VCA ❑ESGIL ❑COMPLETE PLAN CHECK/N/S-STRUCTURAL ATTENTION: TODAY'S DATE: 10.- ?W(f IT, PROJECT ADDRESS: At "Mq APPLICANT NAME: . :YOfpfi SUBMITTAL: ❑iST 4K2 ND BIN NUMBER: ❑ SC INCLUDED HEREWITH: )CLANS ❑REDLINED PLANS STRUCT ❑REDLINED STRUCT ATRUSS ❑REDLINED TRUSS ❑SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY CORRECTION LIST ❑OTHER s DUE DATE. F-13 RD ❑4TH 11 5TH PERMIT NUMBER:y Za�`��� ❑REVISED PLANS ❑REVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS ❑APPROVED PLANS ❑APPROVED STRUCT ❑APPROVED TRUSS ❑APPROVED SOILS KUSTOMER RESPONSES -BUILDING DEPARTMENT USE ONLY - GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS. ❑COVE CHECK (w/Application) LOCATION ON BOARD: LEFT MIDDLE RIGHT SENT TO: SY SSV SH STRUCT/NON-STRUCT ASSIGN NON-STRUCTURAL TO:. I COMMENTS: i i TO: 14YOUNG LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 TRANSMITTAL ❑ESGIL ❑VCA ATTN: i TODAY'S DATE: 4. PERMIT NUMBER: �� ► 0�� PROJECT ADDRESS: APPLICANT NAME: SUBMITTAL ROUND: I C r INCLUDED HEREWITH: PLANS ❑REDLINED PLANS WTRUCT ❑REDLINED STRUCT ❑TRUSS ❑REDLINED TRUSS ❑SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY ❑CORRECTION LIST ❑OTHER BUILDING & SAFETY DEPARTMENT (760) 777-7125 FAX (760) 777-7011 ❑COMPLETE PLAN CHECK/N/S-STRUCTURAL DUE DATE: V BIN NUMBER: ❑REVISED PLANS ❑REVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS ❑APPROVED PLANS ❑APPROVED STRUCT ❑APPROVED TRUSS ❑APPROVED SOILS ❑CUSTOMER RESPONSES -BUILDING DEPARTMENT USE ONLY - GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS ❑COVE CHECK (w/Application) I ASSIGN NON-STRUCTURAL TO: COMMENTS: i.1 YOUNG ENGINEERING 9 E P V i C e G Fax Nal''IR'' i — 6 1 :1 axlmQ W, 1:=0 I ue 1gr �t Letter'of Transmittal To: City of La Quinta Today's Date: 10-1-15 78-495 Calle Tampico City Due Date: 9-30-15 La Quinta, CA 92253 Project Address: 79935 Rancho La Quinta Drive Attn: Kay Plan Check #: BRES 2015-0359 Submittal: 1st M 4th El 2nd El 55th 5 rd El 3 El Other. We are forwarding: By Messenger El By Mail (Fed Ex or UPS) El Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: 1 Structural Plains El Revised Structural Plans 1 Structural Calculations El Revised Struct. Calcs ❑ Truss Calculations Floor ❑ Revised Truss and Roof El Soils Report, El Revised Soils Report 1 Structural Comment List El Approved Structural Plans El Redlined Structural Plans El Approved Structural Calcs El Redlined Structural Calcs El Approved Truss Calcs El Redlined Truss Calcs El Approved Soils Report ❑ Redlined Soils Reports E3 Other: Comments: —Structural content is not approvable. Please refer to comment list. If you have any questions, please call. Time = 1.25 HR This Material Sent for: ❑ Your Files Per Your Request El Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: E] BY: Kathryn Samuels R E C I V E D Palm Desert Office: (760) 772-5107 Other: F-1 OCT 01 2015 CITY OF LA QUINI-A COMMUNITY DEVELOPMENT To: Attn: AdlbV YOUNG ENGINEEINGR e e a v e Pmh (i15U;), T�jfi X07 x {€i60j'7b2{t ma (. fo vague n^groom Ukfeb www v 'lueng .co City of La Quinta Today's Date: 11-5-15 78-495 Calle Tampico City Due Date: 11-9-15 La Quinta, CA 92253 Project Address: 79935 Rancho La Quinta Drive Kay Plan Check #: BRES 2015-0359 We are forwarding: Includes: Comments: # Of Copies: 1 Submittal: ® By Messenger Descriptions: Structural Plans ❑ 1st ❑ 4th ® 2nd ❑ 55th ❑ 3'd ❑ Other: _ Structural Calculations Truss Calculations Floor and Roof Soils Report Structural Comment List/ Responses Redlined Structural Plans Redlined Structural Calcs Redlined -Truss Calcs _ Redlined Soils Reports Structural content is approvable. ❑ By Mail (Fed Ex or UPS) Includes: # Of Copies: ❑ Your Pickup Descriptions:. ❑ Revised Structural Plans ❑ Revised Struct. Calcs ❑ Revised Truss ❑. Revised Soils Report ❑ Approved Structural Plans ❑ Approved Structural Calcs ❑ Approved Truss Calcs ❑ Approved Soils Report ❑ Other: If you have any questions, please call. N0V 0 5 2A, - Time = 1 HR :ITY OF I A 0 ITNTn �— a a AUNITY DEVELOPMFNT This Material Sent for: ❑ Your Files ❑ Your Review . ❑ Checking Other: ❑ By: Kathryn, Samuels Palm Desert Office: ®. (760),772-5107 Other: ❑ ®. Per Your Request ❑ Approval ❑ At the request of: Symbols Numbering System ® General S .ety Notes PLATE LOCATION AND ORIENTATION 1) 3/a Center plate on joint unless x, y offsets are indicated. 6-4-8 1 dimensions shown in ft -in -sixteenths (Drawings not to scale) Failure to Follow Could CZsefl7rj5Ce,0Y Damage or Personal Inj rs 0 1—j O Dimensions are in ft -in -sixteenths. UJ F- Apply plates to both sides of truss1 and fully embed teeth. 2 3 TOP CHORDS t: 1. Additional stability bracing for tru s s g. U diagonal or x -bracing, is always e SIS 01/ �� ' 16 ci-2 c2-3 2. Truss bracing must be designed y ne o m TO®0 3O U may require bracing, or alterna ivLij; I wide truss spacing, individual lair I brat t s sVh z U 3. Never exceed the design load 9999aaaahow er�ievLa stack materials on inadequat y e uss 0 4. Provide copies of this truss de grMoJhe�I�uildin L c2 a cc z cs b O For 4 x 2 orientation, locate plates 0- 'Ag' from outside designer, erection supervisor, rZee tyner and W all other interested parties. Q BOTTOM CHORDS edge of truss. 9 8 7 6 5 5. Cut members to bear lightly agains e 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully. Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from Plate location details available in MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. sottware or upon request. NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted, this design is not applicable for ICC -ES Reports: use with fire retardant, preservative treated, or green lumber. The first dimension is the plate width measured perpendicular 4 x 4 ESR -131 1, ESR -1352, ESR 1988 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to to slots. Second dimension is ER -3907, ESR -2362, ESR -1397, ESR -3282 camber for dead load deflection. the length parallel to slots. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless otherwise shown. in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rel on lumber values g y 14. Bottom chords require lateral bracing of 10 spacing, or less, if no ceiling is installed, unless otherwise noted. BEARING established by others. Indicates location where bearings (supports) occur. Icons vary but © 2012 MiTek@ All Rights Reserved 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. reaction section indicates joint 17. Install and load vertically unless indicated otherwise. number where bearings occur. Min size shown is for crushing only. 111111110_0 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with Industry Standards: W1 project engineer before use. ANSI/TPII : National Design Specification for Metal 19. Review all portions of this design (front, back, words Plate Connected Wood Truss Construction. and pictures) before use. Reviewing pictures alone DSB-89: Design Standard for Bracing. ® is not sufficient. BCSI: Building Component Safety Information, MiTek 20. Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing & Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015