Loading...
BSOL2016-004478-495 CALLE TAMPICO LA.QUINTA, CALIFORNIA 92253 Twit 4 4 Qu&Z COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSOL2016-0044 Property Address: 52945 AVENIDA RUBIO APN: 773312023 Application Description: DIERKS / 7.8kW PV SYSTEM - (28) 260W PANELS W/(1) INVERTER Property Zoning: workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith Application Valuation: $16,016.00 Applicant: --)(4116 / VIVINT SOLAR DEVELOPER LLC 3301 N THANKSGIVING WAY STE 500 permit subjects the applicant to a civil penalty of not more than five hundred dollars LEHI, UT 84043 ($500).: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46, CSO License No.: 9737516 C Date: Contractor: (V ( h I {—S616[K CI GLural lT I IIIIII II'll II'I II'I 11 /4 yp 777-7125 U FAX (760)'777-7011 1:1, . I' SPECTIONS 0760) 777-7153 i 4 r _ ZQfD �l�! COyf c.IlyOF �•-- Date:Fp 3/24/2016 v1UNITyD'Eto QUINjA v Owner: MENTDEpgRTAr.: i SANDRA DIERKS 52945 AVENIDA RUBIO LA QUINTA, CA 92253 Contractor: VIVINT SOLAR DEVELOPER LLC 3301 N THANKSGIVING WAY STE 500 LEHI, UT 84043 (855)877-2974 Llc. No.: 973756 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wo for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: Policy Number: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree that, if I should become subject to the any structure, prior to its issuance, also requires the applicant for the permit to file a workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the comply with those provisions. / Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division --)(4116 / 3 of the Business and Professions Code) or that he or she is exempt therefrom and the Date: �"I V Applicant 0 basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO (� I, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to within one year of completion, the owner -builder will have the burden of proving that the conditions and restrictions set forth on this application. he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made, each person at whose (_) I, as owner of the property, am exclusively contracting with licensed contractors request and for whose benefit work is performed under or' pursuant to any permit to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' issued as a result of this application, the owner, and the applicant, each agrees to, and State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to the work being performed under or the Contractors' State License Law.). following issuance of this permit. (� I am exempt under Sec. . B.&P.C. for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. Date: Owner: . CONSTRUCTION LENDING AGENCY ' I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's I certify that I have read this application and state that the above information is correct. I agree to.comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date 6 Signature (Applicant or Agent): TINANCIAL INFORMATIM DESLRIPtION� >CCOUNT 4TY AMOUNT RAID Pi41DATE" ��,� - BSAS SB1473 FEE 101-0000-20306 0 .$1.00 .$1.00 3/24/16 xry AID BY METHOD Jpl 'REQ PT°# �HECK�# 4 9ft D Y� x. ;' � VIVINT SOLAR DEVELOPER LLC CHECK R14196 1790. MFA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00. $1.00 N DESCRIPTION ACCOUNT QTY AMOUN PAID T PAA 4 PV SYSTEM - ARRAY, FIRST 20 .101-0000-42403 0 .' $24.17 $24.17, 3/24/16 ti aT7 y rs^ RECE P # r CHECK #M0" s METHODz .a , „> aa�s VIVINT SOLAR DEVELOPER LLC CHECK R14196 1790 MFA �s o- c s DESCRIPTION �� � �AC OUNTQ§ m �u A OM UNTO PSA D 4 PRATE w s .�„ `f,-.,, ac., f•s-d �_3`sc„.nz �x.�rw�� PV SYSTEM - ARRAY, FIRST20 PC 101-0000-42600 0 $24.17 • $24.17 3/24/16 SAY yc (.k `PAIDBY; Ys` METHOD ' :n�.tt. RECEIPT # Y N+=M? ✓✓t"r/V .s CHECK # BY VCLTD VIVINT SOLAR DEVELOPER LLC CHECK R14196, 1790 MFA-. Total Paid for ELECTRICAL: $48.34 $48.34 trni` y DESCRIPTION a � iq `5`6^f 0.sS' ` ” ACCOUNT �Q Y� F - '. d '$,ft -5 2i .�Ii s�R'( Imo. aA—,Wr„n^'.�"��a �%Tf n n , AN1OUN :£ PERMIT ISSUANCE _ 101-0000-42,404 0 ' . $91.85 $91.85 3/24/16 PAID BY N'2. fixss,":5'sk4 h?METHOD��� t.&r 4 ECEIPuT��HECKz#€ PENN Xi5'cs^3r� �CLTD BYE v 0, t R �� �- ��. VIVINT SOLAR DEVELOPER LLC CHECK R14196 1790, MFA Total Paid for`PERMIT ISSUANCE: $91.85 ,$91:85 TOTALS: Description: DIERKS / 7.8kW PV SYSTEM - (28) 260W PANELS W/(1) INVERTER Type: SOLAR Subtype: Status: ISSUED Applied: 2/16/2016 SKH Approved: 3/24/2016 AOR Parcel No: 773312023 Site Address: 52945 AVENIDA RUBIO LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 170 Lot: 10 Issued: 3/24/2016 MFA UNIT 17 ACTION DATE COMPLETION DATE Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $16,016.00 Occupancy Type: Construction Type: Expired: 9/20/2016 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 EMAIL SENT TO APPLICANT Details: 7.8kW SOLAR ARRAY - (28) 260W YINGLI PANELS+P300 SOLAREDGE OPTIMIZERS AND (1) SE6000-US-R AFCI SOLAREDGE INVERTER [504SF] THIS PERMIT DOES NOT INCLUDE CHANGEOUT OF ELECTRICAL SERVICE, PER PLAN THIS SCOPE OF WORK WILL BE PERMITTED SEPARATELY. 2013 CALIFORNIA ELECTRICAL CODE. ,Applied to Approved - Approved to Issued ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL SENT TO APPLICANT (PAULA.HOFFMAN@VIVINTSOLAR.COM) THAT PLANS ARE READY FOR CORRECTIONS; INCLUDED 1ST REVIEW E-MAIL AJ ORTEGA 2/23/2016 2/23/2016 ATTACHMENTS, SEE REVIEW COMMENT FOR ADDITIONAL INFORMATION. EMAIL SENT TO PAULA (CONTRACTOR) THAT PLANS ARE E-MAIL AJ ORTEGA 3/24/2016 3/24/2016 APPROVED AND PERMIT IS READY TO ISSUE. RESUBMITTAL AJ ORTEGA 3/16/2016 3/17/2016 PLAN CHECK RESUBMITTAL RECEVIED VIA EMAIL, LOGGED FOR 3/16/2016 CONDITIONS Printed: Thursday, March 24, 2016 2:07:21 PM 1 of 3 Cb? SYS7EnA5 INSPECTIONS Printed: Thursday, March 24, 2016 2:07:21 PM 2 of 3 r> �SYSTEMS. FAX EMAIL NAME TYPE NAME ADDRES91 CONTACTS CITY STATE ZIP PHONE APPLICANT VIVINT SOLAR DEVELOPER LLC 3301 N THANKSGIVING WAY LEHI UT 84043 (760)464-1515 AMOUNT businesslicensing@vivi nsolar.com CONTRACTOR VIVINT SOLAR DEVELOPER LLC 3301 N THANKSGIVING WAY LEHI UT 84043 (760)464-1515 businesslicensing@vivi nsolar.com OWNER SANDRA DIERKS 1 52945 AVENIDA RUBIO I LA QUINTA I CA I 92253 (760)464-1515 1 . INSPECTIONS Printed: Thursday, March 24, 2016 2:07:21 PM 2 of 3 r> �SYSTEMS. FINANCIAL INFORMATION ' CL DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 3/24/16 R14196 1790 CHECK VIVINT SOLAR MFA DEVELOPER LLC Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM -ARRAY, 101-0000-42403 0 $24.17 $24.17 3/24/16 R14196 1790 CHECK VIVINT SOLAR MFA FIRST 20 DEVELOPER LLC PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $24.17 3/24/16 R14196 1790 CHECK VIVINT SOLAR MFA FIRST 20 PC DEVELOPER LLC Total Paid for ELECTRICAL: $48.34 $48.34 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 3/24/16 R14196 1790 CHECK VIVINT SOLAR MFA DEVELOPER LLC Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS:, INSPECTIONS Printed: Thursday, March 24, 2016 2:07:21 PM 2 of 3 r> �SYSTEMS. Permit Details PERMIT N6MBER r City of La Quinta BSOL2016=0044 ` CORRECTIONS SIMILAR TO PERMITS BSOL2016- 0041 AND 0042, SPOKE WITH APPLICANT AND 1ST BLDG NS (1 WK) AJ ORTEGA 2/16/2016 2/23/2016 2/23/2016 REVISIONS REQUIRED SHE IS AWARE OF THE COMMENTS AND GOING TO MAKE THE CORRECTIONS ON ALL SUBMITTED PLANS AND HOLD OFF ON SUBMITTING FURTHER APPLICATIONS UNTIL CORRECTED. 2ND BLDG NS (1 AJ ORTEGA 3/16/2016 3/23/2016 3/23/2016 APPROVED WK) Printed: Thursday, March 24, 2016 2:07:21 PM 3 of 3 CPNAAF SYSTEMS `Attachment Type CREATED OWNER DESCRIPTION - PATHNAME - SUBDIR ETRAKIT ENABLED BSOL2016-0044 - 2ND 2ND SUBMITTAL SOLAR SUBMITTAL SOLAR DOC 3/17/2016 AJ ORTEGA PLAN (REVISED SHEETS PLAN (REVISED SHEETS 0 ONLY) ONLY).pdf Printed: Thursday, March 24, 2016 2:07:21 PM 3 of 3 CPNAAF SYSTEMS sin.# Of La Quints BLArlog 8r Safety D"lon P.O. Box 1504,78-495 Calle Tampico La.Qointa, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: J�' ;� I I/e I i TA16 Owner's Name:. Sa Ar&A 1 !r k . . A P. Number. 3 I Q7 �3 /S Address: �a 9 4 J V/Alda Legal Description: City, ST, Zip: L �� 9 2 qi, j3 a QJIh q Contractor. VIU 11d'Q1" e 4d -er C LL S � Telephone• o- S ,...,� .•�: Project Description:(eeA II Address: JrG Ale, Zq City, ST, Zip: CA+k C U ,•� C/ 9 2 x 3 f� - - 4 u e a 8 a A Telephone: 9 �� a-3 —� !6• ,� ;�• a lll,� / � fi ✓�✓ft°� State Lic. # : a-76-15-2 City Lic. #:L• IC- &3 i&p Arch., &W., Designer Address: City., ST, Zip: Telephone: .6 State Lic. #: Name of Contact Person: Q�h 1Q A Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: -.3 � eq Estimated Value of Project 747 . -aa APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd 'Reed TRAQMG PERMIT FESS Plan Sets Plan Check submitted Item Amount Stroctund Cities. Reviewed, ready for corrections Plan Check Deposit. . Truss Coles. Called Contact Penon Plan Check Balance Title 24 Coles. Plans picked up Construction Flood plain plan Plans resubmitted. ' , Mechanical Grading plan 2'' Review, ready for tionsf a El dial Subcontactor List Called Coutact non P bing Grant Deed Plans picked up S M L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review; ready for to a Developer Impact Fee Planning Approval Called Contact Person I.A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees t NEW PV SOLAR SYSTEM -- FOR ` 1 1 o Ln Dierks Residence LO co . t, _ Z LOCATED AT - k J.� R ' R?! '�:: 1 Z �o rn O U -i 52945 Avenida Rubio 1 19 La Q CA 92253 r1 , 0 0 `/ 1/ r O � J �, II/J P N # 773312023 —Ago: GOVERNING CODES SHEET INDEX _ N V 05 LD ALL WORK SHALL COMPLY WITH THE CODES BELOW - COVER SHEET O N N J All construction shall comply with the 2013 California Building, Residential, Mechanical, P.V. 1.0 SITE PLAN Ir A CN Electrical, Plumbing, Energy and Green Building Codes and La Quinta Municipal Code CITY.�`� �•••�•-•k '`" < r P.V. 2.0 ROOF PLAN BUILDING & SAFETY DEPT. J L?� U O U v cn PROVED e- • co LO u7/Ar- P.V. 3.0 MOUNTING DETAILS FOR CONSTRUCTION % tOa 0 rn O> h E DATE 1otb ��°''��"'�j� w W W CO E. 1.0 1—LINE DIAGRAM `''`e CJ J Q J Q N j Q U Z � � Uof ? ? SHEET - NAME. Of I— Ljj iii > w O A� SHEET "CLASS "A" FIRE RATED MODULES AND RACKING SYSTEMS REQUIRED PER NUMBER: U.L. 1703 AND CSFM 14-011" Photovoltaic equipment and systems and all associated wiring and interconnections shall be installed ' only by qualified persons. CEC 690.4 U. PV SYSTEM SURFACE AREA:490.56 FTI PV SYSTEM SIZE: 7.280 kW DC PV SYSTEM SIZE: 6.416 kW AC BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION JUNCTION BOX ATTACHED TO ARRAY USING ROCK -IT TO KEEP JUNCTION BOX OFF ROOF 35' OF 3/4" OR 1" EMT ON ROOF FROM JUNCTION BOX TO ELEC PANEL "CLASS "A" FIRE RATED MODULES AND RACKING SYSTEM REQUIRED PER U.L.1703 AND CSFM 14-011" -SAFETY OFFSET FOR ROOF ACCESS ALL WORK SHALL COMPLY - EXISTING SOLAR WITH THE 2013CEC PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TARE, TAGGING OR OTHER APPROVED MEANS. THE MEANDS OF THE GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX(6) FEET. i llioia;tfq��, ao4oea_ P,+, oCo Y E C i /� 1� �co yr0 e` °° J. 973 °.• rdV {28) Yingli Energy YL260P-29b MODULES WITH 28 SolarEd a P300 Power Optimizers MOUNTED ON THE BACK OF EACH MODULE a M Lo N N Q U cu 0 J o_ cu .c Lo �TT V, N Lo PV SYSTEM SITE PLAN SCALE: 1/8"= V-0" N W U U 0 W j N W �C-4m �UZ 2z L00'O L L J F}tea- 0 J F- rn _N OLo UM, v O co to : It0 0 U N N H W n Z m M W O>��^, E } > Z 1- W W Z [0 -i ul z H H -i Q�Q Z co Z 0 0 SHEET NAME: SHEET NUMBER: 0 Roof Section 2 Roof Aamuth 0 Roof Tilt 12 COMP SHINGLE Roof Sectlon 1 Roof Azimuth: 180 Roof Tilt: 12 COMP SHINGLE SYMBOL KEY: O PLUMBING VENT(S) CHIMNEY SATELLITE SW ROOFTOP SWAMP COOLER ---- EXISTING CONDUIT m DISH ROOF VENT(S) J/ SKY LIGHT(S) R ELECTRICAL MAST AC ROOFTOP AC UNIT TIE INTO M 1134SR- 006711TY METER # § %\61's � 00%, 41 PV SYSTEM ROOF PLAN SCALE: 3/16" = V-0" N th U0 C LO 04 w 'a Q.NM rn� �N �UZ LL Q c Z � U', O L LJQ H Z) O) N CD u7 U `? v v It(D < U OD O In w rn OF- W L > 0) E > Z w U) O w w m W V J J Z U J J LU Z J< U) fn J (aj Z Z Z U O SHEET NAME: LL Oz O -j a SHEET NUMBER: N {.L MINIMUM DESIGN LOADS Ground Snow Load 0 Wind Speed 130 EXPOSURE CATEGORY B PV MODULE, TYP. MOUNT TO RAFTERS OF COMP. SHINGLE ROOF, PARALLEL WITH PLANE OF ROOF CC ISE/RUN 3 MOUNTING . DETAIL PV ARRAY TYP. ELEVATION NOT TO SCALE TORQUE TO 7 FT -LBS (1/4'•28 SS SCREW) 6 AWG TO 14 AWG COPPER WIRE— L TORQUE TO 7 FT -LBS WITH NEW GBL-4DBT UL2703 Listed Lay -In Lug (1/4••20 SS SCREW) 2. UL LISTED LAY -IN LUGS TEETH MUST FACE TOWARDS THE RAIL, NOT THE GROUND LUG 3. DRILL A 17/64" HOLE TO THE GROUND LUG (AS NEEDED) 4. NO SURFACE PREPARATION IS NEEDED ON RAIL OR MODULE CLAMP + kCHMENT PLING FASTEN PATIBLE ULE �w vl r, L=LANDSCAPE MODULE CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE CLAMP SEALING WASHER FLASHING 5/16"0 x 4 1/2" MINIMUM STAINLESS STEEL LAG SCREW TORQUE = 13±2 ft -lbs e 9 7 -3,e ,bc, e 'eoe eoe 00 CANTILEVER U3 OR LESS SPACING) L= 48" MAX CLAMP SPACING ,72- MAX CLAMP SPACING LANDSCAPE SPACING) L= 48" MAX CLAMP SPACING ,64" MAX CLAMP SPACING LANDSCAPE COUPLING CLAMP PHOTOVOLTAIC MODULE . PV SYSTEM MOUNTING DETAIL NOT -TO SCALE :�k -� OF C�►1.�F Truss 2x4 AT 24" O.C. L_ fin � 8 u7 0 S_ N_ v w 0 J rn . N _D o ul Uto v 0 U-) -- IwL rn O> 2 rn E W > =Z' w U J J Z 07 J J U Z U Q U) U) Q Z Z Z U SHEET NAME: Zo J � p SHEET NUMBER. M 28 PV MODULES PER INVERTER =7280 WATTS STC 1 STRING OF 14 PV MODULES 1 STRING OF 14 PV MODULES SOLAREDGE P300 OPTIMIZER? SC P300 0 0 0 0 0 0 0 0 0 13 0 0 0 * CONFORMS TO ANSI C12.1-2008 Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) Tag # Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 1 PV Wire 10 AWG 2 (V+, V-) N/A -Free Air N/A -Free Air 1 Bare Copper Ground (EGC/GEC) 6 AWG 1 BARE N/A -Free Air N/A -Free Air 2 THWN-2 8 AWG 4 (2V+, 2V-) R/B EMT 3/4" 2 THWN-2 - Ground 8 AWG 1 GRN EMT 3/4" 3 THWN-2 8 AWG 3 (11-1, 11.2 1N) B/R/W EMT 3/4" 3 THWN-2 - Ground 8 AWG 1 GRN EMT 3/4" 1SOLAREDGE SE6000A-US-R INVERTER' II SOLAREDGE ti DC SAFETY / SWITCH JUNCTION BOX/ WITH IRREVERSIBLE GROUND SPLICE CONFORMS TO NEC 2014 EQUIVALENT CID Z 11lapa`t u S n 4 `��,;til� LOAD -CENTER SN NEW ELECTRICAL PANEL TO BE PULLED UNDER SEPARATE PERMIT POINT OF W In WITH 1-2 POLE 35A = VISIBLE CD N Z7 LOAD SIDE LOCKABLE JUNCTION BOX/ WITH IRREVERSIBLE GROUND SPLICE CONFORMS TO NEC 2014 EQUIVALENT NEW 225/200 LOAD CENTER 35A 240V/225A AC Z z - u S n 4 SHEET LOAD -CENTER NAME: NEW ELECTRICAL PANEL TO BE PULLED UNDER SEPARATE PERMIT POINT OF W WITH 1-2 POLE 35A CONNECTION- L, L2 N VISIBLE SOLAR BREAKER o W LOAD SIDE LOCKABLE INIMUM GEC SIZE ly W NEC 705.12(D) M 3 " � " M w t 0 J < 0 Q * U) E Q Square D #DU222RB 240V/60A UNFUSED 200A a J Z m NEMA3 a z JUNCTION BOX/ WITH IRREVERSIBLE GROUND SPLICE CONFORMS TO NEC 2014 EQUIVALENT NEW 225/200 LOAD CENTER 35A 240V/225A AC Z z - u S n 4 SHEET LOAD -CENTER NAME: W WITH 1-2 POLE 35A VISIBLE SOLAR BREAKER o W LOCKABLE INIMUM GEC SIZE ly W KNIFE' DISCONNECT 2 AWG COPPER im Z EC J < 0 Q * U) E Q SHEET NUMBER: O Created with Electrical Template Revision 9/10/15 r. W I Design Conditions: I ROOFTOP CONDUCTOR AMPACITIES DESIGNED IN COMPLIANCE WITH NEC 690.8, TABLES 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), CHAPTER 9 TABLE 4, 5, & 9. LOCATION SPECIFIC TEMPERATURE OBTAINED FROM. ASHRAE 2013 DATA TABLES. ASHRAE 2013 Highest Monthly 2% DB Design Temp 47°C. Lowest Min. Mean Extreme DB -7.5°C � DC Safety Switch: Rated for max operating condition of inverter NEC 690.35 compliant *opens all ungrounded conductors Calculations: Breaker calculations dependent upon inverter Continuous Maximum Output. Wire Gauge Calculated from NEC code 310.15(B)(16) with ambient temperature calculations from NEC 310.15(2)(a) using the 90°C column (On Roof) or 75°C column (Off Roof), *310.15(B)(3)(c) for 1/2" minimum clearance of the conduit above the roof and 310.15(B)(3)(a) Adjustment factor for current -carrying cunductors in a raceway. WITH .82 AMBIENT - When a wire is upsized in the conduit conductor table, voltage drop adjustments were made TEMPERATURE SE6000A-US-U Max Output = 25.00A x 1.25 (NEC code 210.19(A)(1)(a))=31.30A. CONDUCTOR STILL (off roof): 8 gauge wire rated for SOA > 31.30A (max of solar panel production). COMPLIES: 50A X.82 41 A > 31.3A (on roof): 8 gauge wire rated for 55A x 0.50 (ambient+*22°C) x 0.800000 (fill derate of 4 current -carrying conductors = 22.00 > 18.75A Max circuit output per circuit 15 x continuous duty uprating 125%). Svstem Saecs: Max DC Voltage Nominal DC Operating Voltage Max. DC Current per String Nominal AC Current 500V 350V 15A 47.5A PV Module Rating @ STC Model Make/Model YL260P-29b Amps Max Power -Point Current (Imp) 8.59 Amps Max Power -Point Voltage (Vmp) 30.3 Volts Open -Circuit Voltage (Voc) 37.7 Volts Short -Circuit Current (Isc) 9.09 Amps Max Series Fuse (OCPD) 15 Amps Nominal Maximum Power at STC (Pmax) 260 Watts Maximum System Voltage 1000 V (IEC) / 600 V (UL) Volts Voc Temperature Coefficient -0.32 %/C Other Notes Solar PV System AC Point Of Connection AC Output Current Accoding to Nec 690.8(B)(1) 31.3 Amps Nominal AC Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Optimizer Solar Edge P300 DC Input Power 300 Watts DC Max Input Voltage 8-48 Volts DC Max Input Current 12,5 Amps DC Max Output Current 15 Amps Max String Rating 5250 Watts Inverter Make/Model SE6000A-US CEC Efficiency 97.5 % AC Operating Voltage 240 Volts Continuous Max Output Current 25 Amps DC Maximum Input Current 18 Amps Short Circuit Current 27.5 Amps a t r BUILDING & SAFETY DEPT. APPROVED . FOR CONSTRUCTION DATE BY 27,5 A/20ms - ' �0 - awrf •ti V`•` 02 tn to SHEET NAME: SHEET NUMBER r W INVERTER GROUNDED SYSTEMS PER 690.5(C)M NPHASE: Al J-13 WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED COMBINER BOXES, J -BOXES, DISCONNECTS, DEVICES & INVERTERS IN UN -GROUNDED SYSTEMS PER 690.35(F) ZING SYSTEM WARNING ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED CONDUIT AND RACEWAYS (LABELED EVERY 10') WARNING: PHOTOVOLTAIC POWER SOURCE DC DISCONNECT PER 690.17 & 690.53 SOLAR DC DISCONNECT WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC POWER SOURCE DC DISCONNECT RATED MAXIMUM POWER POINT CURRENT (IMP) 8.S9 A RATED MAXIMUM POWER POINT CURRENT (VMP) 30.3 A MAXIMUM SYSTEM VOLTAGE (VOC) 37.7 V SHORT CIRCUIT CURRENT (ISC) 9.09 A DERATE OF MAIN BREAKER DUE TO SOLAR MAIN BREAKER DE -RATED DUE TO SOLAR CIRCUITS AMPS MAX ALLOWED DO NOT UPGRADE NOTE: SIGNAGE CHARACTERISTICS - MIN. 3/8, REFLECTIVE, WHITE, ARIAL, ALL CAPITAL LETTERING ON RED BACKGROUND MADE OF WEATHER RESISTANT MATERIAL. AC DISCONNECT AND ANY LOAD CENTERS (COMBINER PANEL) PER 690.17(E) & 705.12 SOLAR AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT. 39.6 A NOM. OPERATING AC VOLTAGE: 240 V WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION INVERTER OUTPUT CONNECTION (SOLAR BREAKER) AT MAIN SERVICE PANEL PER 705.12 WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENTDEVICE MAIN SERVICE PANEL SIGNAGE (INSTALLED ON THE FACE OF THE SERVICE METER) PER 690.54, 690.56(B) & 705.10 NOTE: Roofline Placard not needed unless PV disconnect is not at same location as Main Service CAUTION: SOLAR ELECTRICAL SYSTEM CONNECTED nuz\'C'�' ER TO THIS FROG THE FC • -ONNd CITY OF LA QUILT -- BUILDIN &&SAF`ETY DE' AP ■ lO Y/ED FOR qONSTRUCTION SERVICE PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT: 39.6 A NOM. OPERATING AC VOLTAGE: 240 V %%J11111illf�, Cir, ' o Cody E. Orarr 7 3 to ls02. sGd Qr� ` ♦^°. c" w ko M N Ln M c N Vl W m M o v Q Ln jLn �� V Y ro c Q qr C7 f >- o NJ 4-1 Ln __j U Ol N v T v o Y � U L h 0a4 g Cq s O .1 U c V) Ln co Y Z m r• >_ ^ m > Z a' w N Ln J LLJJ Z J J LLJ U N N J z z U N SHEET NAME: W a z N (SHEET NUMBER: O WARNING CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC DISCONNECT ELECTRICAL SHOCK HAZARD Pro a of Vivint Solar3 Property of Vivint Solar THE DC CONDUCTORS OF THIS RATED AC OUTPUT CURRENT: 39.6 A 10PHOTOVOLTAIC SYSTEM ARE UNGROUNDED MAIN BREAKER DE -RATED DUE TO SOLAR CIRCUITS NOM. OPERATING AC VOLTAGE: 240 V AND MAY BE ENERGIZED !� AMPS MAX ALLOWED 11 SOLAR DC DISCONNECT L DO NOT UPGRADE WARNING Property of Vivint Solar Property of Vivint Solar ELECTRICAL SHOCK HAZARD. 7 DO NOT TOUCH TERMINALS. TERMINALS SOLAR DC DISCONNECT ON BOTH THE LINE AND LOAD SIDES Property of Vivint So PHOTOVOLTAIC POWER SOURCE MAY BE ENERGIZED IN THE OPEN POSITION Property of Vivint Solar Property of Vivint Solar RATED AC OUTPUT: 39.6 A PHOTOVOLTAIC POWER SOURCE DC DISCONNECT NOM. OPERATING AC VOLTAGE: 240 VQ CAUTION: SOLAR CIRCUIT "` RATED MAXIMUM POWER POINT CURRENT (IMP) 8.59 A Q Property of Vivint Solar 12 RATED MAXIMUM POWER POINT CURRENT (VMP) 30.3 A MAXIMUM SYSTEM VOLTAGE (VOC)37.7 V /� WARNING ` --� SHORT CIRCUIT CURRENT (ISC) 9.09 A INVERTER OUTPUT CONNECTION WARNING Property of Vivint Solar DO NOT RELOCATE OVERCURRENT DEVICE ELECTRICAL SHOCK HAZARD �- - 9 IF A GROUND FAULT IS INDICATED SITE PLAN PLACARD SHOWING ADDITIONAL POWER PHOTOVOLTAIC NORMALLY GROUNDED CONDUCTORS 13 SOURCE AND DISCONNECT LOCATIONS. PLACARD AC DISCONNECT MAY BE UNGROUNDED AND ENERGIZED SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL .. Property of Vivint Solar r PANEL (only when necessary) 12 CITY OF LA QUINTA 13 BUILDING & SAFETY DEPT. IF APPLICABLE APP ®VE® 7 7 FOR C PP UCTION 3 3 DATE �BY `�voe 49�so.eaz�v°,moot & O' A ROOFTOP ARRAYa 10 V V V c c c 2 2 _ s ^.A EVERY 10' ;1 �I�0e`o e AND WITHIN 1' �� �� °°° V" X731v°°° CJS o �I OF ELBOWS - - 7 5 5 5 C ////7rrrn,'e••L1'� g• �S'O��QGA �p Nrr r A A (Y� !� SOLAR 8 of 88 FG INVERTERS - .. O,o.�iOF STRING -INVERTER .. M SYSTEMS • DC 9 _ DISCONNECT INSIDE [OR) fttl Olga E5 9w I ow Aw a111 ad A?°tos .�Yf': ik.- r ��' -. (MAY BE ON ROOFTOP COMBINER VISIBLE/LOCKABLE SUB PANEL � MAIN SERVICE 10 ' INTEGRATED WITH ARRAY) PANEL A/C DISCONNECT VIVINT SOLAR METER VISIBLE/LOCKABLE (WHEN DISCONNECT JUNCTION p (WHERE REQUIRED) A/C DISCONNECT BOX 8 (WHERE REQUIRED) REQUIRED) n PANEL STRING -INVERTER '+ SYSTEMS TYPICAL SOLAR GENERATION INSTALLATION INSIDE PANEL INSIDE PANEL (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) 4 THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC) CONDUIT, ENCLOSURES, ALL STICKER DESCRIBED HERIN SHALL BE MADE OF A WEATHER PROOF ADHESIVE, THEY SHALL BE REFLECTIVE, REALE-WAYS, CABLE ASSEMBUMJUNCIION BOXES, COMBINER BOXES. AND DISCONNECTS TO ALERT THE FIRE SERVICE TO AVOID CU`MNG THEM. MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (30x8 MML WITHIN I FOOT (305 THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND MM) OF TURNS OR BENDS AND NTTHIN I FOOT (305 MML ABOVE AND BELOW PENETRATIONS OF ROOFICEILING ASSEMBLIES, WALLS OR BARRIERS w C N V1 a m o u In a c :It j 'o u 1O ` a wm c O N M L L CID 0 cn c N m v U 01 N rI U n c6 L U Oq O u c N OC I,D C � W ell N Z m n Y > a Z m m W J Z 01 J J W qt _U N N J z z V n SHEET NAME: rNr^^ ca z Z m °C g3 SHEET NUMBER: O J O ie���`+111111111I'rrr r [� Q,ry+c.�, 001-11, a .. r ����� 'a r r s v. POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR MODULES WITH POWER OPTIMIZERS MOUNTED ON THE BACK OF EACH MODULE JUNCTION BOX LOCATED ON ROOFTOP PV INTERCONNECTION POINT LOCKABLE DISCONNECT SWITCH,& UTILITY METER LOCATION 52945 Avenida Rubio vivint. solar Structural Group 3301 North Thanksgiving Way, Suite 500 Lehi, UT 84043 P: (801) 234-7050 Scott E. Wyssling, PE Senior Manager of Engineering scdff.wyssling@vivintsolar.com vivintsolar.com February 16, 2016 Mr. Dan Rock, Project Manager Vivint Solar 3301 North Thanksgiv ngCaih ' Q I NTA Lehi, UT 84043 �� jj �� BUILDING & SAFETY DEPS APPROVED FOR CONSTRUCTION Dear Mr. Rock: I DATES �Ot�OBY Structural Engineering Services Dierks Residence 52945 Avenida Rubio, La Quinta CA S-4746495 7.28 kW Re6rb" V • vu" Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof Sections (1 and 2): Prefabricated truss with all chords constructed of 2x4 dimensional lumber at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Douglas -Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 130 mph based on Exposure Category C and 12 degree roof slopes on the dwelling areas. 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivint. solar Page 2 of 2 B. Loading Criteria 10 PSF = Dead Load (roofing/framing) 20 PSF = Live Load (ground snow load) 3 PSF = Dead Load (solar panels/mounting hardware) Total Dead Load = 13 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2013 California Building Code. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent 'Mounting System Inc. Installation Manual'; which can be found on the Mounting System Inc. website (usa.mounting- systems.irifo/en/solar-mounting-systems-company). If during solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 1/V thick and mounted 4 W' off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6" above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 235 IbsAnch of penetration as identified in the Nation Design Standards (NDS) of timber construction specifications for Douglas -Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2', is less than the maximum allowable per connection and therefore is adequate. 4. Roof Sections (1 and 2): Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every third roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than three (3) spaces or 72" o/c, whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2013 California Building Code, current industry standards and practices, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Aly yours, . Wysslin CA License No. vivint. solar -vivint. solar Structural Group 3301 North Thanksgiving Way, Suite 500 Lehi, UT 84043 P: (801) 234-7050 Scott E. Wyssling, PE Head of Structural Engineering Structural Analysis Report scott.wyssling@vivintsolar.com Project Address Dierks Residence 52945 Avenida Rubio La Quinta, CA ' ' Residence Roof Area 3000 ft2 Upper Floor Area 0 ft2 Lower floor Area 2500 ft2 Number of Stories 1 Type of Construction Wood -Framed with Rated shear panels Mean Roof height 15 ft Upper Floor height 0 ft Lower Floor height 10 ft Location Parameters Latitude Longitude Site Class Risk Category Seismic Parameters Ss = S, _ Fa F„ _ 33.841 -117.85 D 11 Date: February 16, 2016 1.50 g 0.2 sec Spectral Response Acceleration 0.55 g 1.0 sec Spectral Response Acceleration 1.0 Site Coefficient from ASCE 7-10, Table 11.4-1 1.5 SDs = 1-009 SD, = 0.55 g Wind Parameters Wind Speed 130 mph Exposure Category C Roof Angle, Q 12.0 deg Product Information Manufacturer Yingli Solar No. of Panels 28 Weight 3.00 psf Installed Area 492.24 No. of Connectors 37 Site Coefficient from ASCE 7-10, Table 11.4-2 Short Period Design Spectral Acceleration 1 Second Period Design Spectral Acceleration including mounting system ft2 2012 IBC / 2013 CBC Section 3403.4 states: "Any existing lateral load -carrying structural element whose demand -capacity ratio with the addition considered more than 10 percent greater than its demand -capacity ratio with the additoin ignored shall be permitted to rerr unaltered." Sheet 1 of 5 vivant. soIa r Existing Additional Total Gravity Loads Existing Structural Elements Carrying Gravity Load 2013 California Building Code Section 3404.3 Roof Dead Load 4 psf Composite Shingle 2 psf 3/4" Plywood Sheathing 0.75 psf Roof Framing @ 24" o.c. 2 psf Ceiling, Mechanical, Electrical 1.25 psf Miscellaneous 10 psf TOTAL Floor Dead Load 7.5 psf Floor Finishes 3.3 psf 1 1/8" Subfloor Sheathing 3.4 psf Joists @ 16' o.c. 15 psf Partitions 3.6 psf Ceiling, Mechanical, Electrical below 1.2 psf Miscellaneous 34 psf TOTAL Roof Live Load 20 psf Reducible Floor Live Load 40 psf Reducible Roof Dead Load 3 psf Yingli Solar Roof Live Load with Solar Panels 0 psf Total Existing Roof Load = (DLRooF+ LLRooF) AreaRooF = 90000 lbs Total New Roof Load = (DLRooF) Area ROOF+ (DLADD) AreaADD + (LLRooF) (AreaRooF - AreaADD) = 91477 lbs Change in Demand = (Total New Roof Load - Existing Roof Load) / Existing Roof Load 1.64% Total New Gravity Loads increase by less than 5%. OK Sheet 2 of 5 wawnnl S no � a r Base Shear Calculations 2012 IBC / 2013 CBC 3404.4 Site Class = D Risk Category = II SDs = 1.00 SDI = 0.55 Lateral force resisting system: Wood -Framed with Rated shear panels R,, = 6 1/2 from ASCE 7-10, Table 12.2-1 I = 1.0 h = 15.0 ft Mean Roof Height C, = 0.02 from ASCE 7-10, Table 12.8-2 x = 0.75 from ASCE 7-10, Table 12.8-2 TX = Cthn" = 0.152 sec Approximate Fundamental Period, ASCE 7-10, Equation 12.8-7 WEXISnivo = 115.00 kip Approximate mass of building WHEW= 116.48 kip Approximate mass of building and solar panels Base Shear = SDR I W= 0.154 x W ASCE 7-10, Equation 12.8-2 Max Base Shear = T x R W = 0.556 x W ASCE 7-10, Equation 12.8-3 Min Base Shear = .044 SDs XI (> 0.01) x W 0.044 x W ASCE 7-10, Equation 12.8-5 Cs = 0.154 Static Base Shear, Vx = 17.69 kip Existing 17.92 kip New 1.28 % increase INCREASE IS LESS THAN 10% - OK Sheet 3 of 5 1vl o Zvo nl so l a r Existing New Vertical Distribution of Seismic Forces 2012 IBC / 2013 CBC 3403.4 k = 1.00 Structural Period Exponent from ASCE 7-10 Section 12.8.3 V = 17.69 kip V = 17.92 kip Weight Story ry k w; h; ` Diaphragm Force Story Level -- Height, h', hi (ft) w; h; Force (kip) h�k) (�P) (ft)S(w; (kio) Roof 30.00 15 25 750 0.469 8.29 8.29 Upper 0.00 0 10 0 0.000 0.00 8.29 Lower 85.00 10 10 850 0.531 9.40 17.69 SF 115.00 25 1600 1.000 17.69 V = 17.92 kip Demand Increases Diaphrag Weight story k w; hi Diaphragm Force Story Level -- Height, h,, h; (ft) w; h; Force (kip) S(w; h; `) (kip) (ft) Roof 31.48 15 25 787 0.481 8.61 8.61 Upper 0.00 0 10 0 0.000 0.00 8.61 Lower 85.00 10 10 850 0.519 9.31 17.92 SF 116.48 25 1637 1.000 17.92 Demand Increases Diaphrag Story Level m Force Force (kip) Roof 3.87% 3.87% INCREASE IS LESS THAN 10% - OK Upper -- -- Lower -1.00% 1.28% NET DECREASE IN SEISMIC LOAD - OK Sheet 4 of 5 1v/ nwa nl so I a r Wind Uplift Simplified Procedure for Componenets and Cladding ASCE 7-10, Section 30.5 V = 130 Basic Wind Speed Exposure C ASCE 7-10, Section 26.7 = 1.21 Adjustment Factor for building height, ASCE 7-10, Figure 30.5-1 KZt = 1 Topographic Factor, ASCE 7-10, Section 26.8.2 Roof Zone 2 As shown in ASCE 7-10, Figure 30.5-1 Roof Q = 12 deg Apanel = 492.24 ftZ AU;b = 12.99 ft2 Panel Area tributary to each roof anchor Pnet30 = 38 psf Net Wind Design Pressure, ASCE 7-10, Figure 30.5-1 Pnet = IKZtpnet3o = 46 psf Design Wind Uplift Pressure, ASCE 7-10, Equation 30.5-1 Pnet = 16 psf Minimum Design Wind Pressure, ASCE 7-10, Section 30.2.2 Use 46 psf Connection to Existing Roof Framing F.S. = 1 Additional Factor of Safety applied to withdrawl force, if desired Atrib = 12.99 ft DLpanel = 3.00 psf Wupiift = 46 psf Plag = F.S. x Atrib x (0.613- 0.6W) _ -335.1 lbs Withdrawl force for each roof anchor Connection Capacity db = 5/16 in Lag Screw diameter DNn = 2.50 in Lag Screw penetration into existing framing member Douglas Fir -Larch Species of wood framing Co = 1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 Ct = 0.7 Temperature Factor, NDS Table 10.3.4 W = 266 lb/in Withdrawl Capacity, NDS Equation 11.2-1 W'= CD x Ct x W = 298 lb/in Adjusted withdrawl value Pauow = Dpen x W' = 745 lbs DEMAND = 335 lbs = 0.450 OK CAPACITY = 745 lbs Sheet 5 of 5 vivin't. sC=))l � a r STRUCTURAL ENGINEERS October. 23, 2015 Rillito River Solar, LLC dba EcoFasten Solar 289 Harrel Street Morrisville, VT 05661 TEL: (877) 859-3947 Attn.: Engineering Department, Re: Engineering Certification for the EcoFasten Rock -it System Installation Manual This letter is to document that PZSE, Inc. -Structural Engineers has reviewed EcoFasten Rock -it System Installation Manual published October 12, 2015 and specifically the "Loading Tables". SCOPE OF THE SYSTEM: The EcoFasten Rock -it System is a solar panel support system for installing solar photovoltaic arrays on sloped roofs of buildings. Typically such buildings are residential with shingle or the roofs. The number and spacing of attachments to the roof structure can vary depending on various site specific criteria including, but not limited to, roof slope, spacing of supporting structural members and environmental loading. SCOPE OF OUR REVIEW: PZSE, Inc.—Structural Engineers provided a review of the following • Rock -it System design methodology • Rock -it System Installation Manual • Rock -it System Loading Tables and has determined that all information, data and analysis contained within the Installation Manual are based on, and are in compliance with, the structural requirements of the following Reference Documents: • Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-10 • International Building Code, 2012 Edition, by International Code Council, Inc. • California Building Code, 2013 Edition, by California Building Standards Commission • Aluminum Design Manual, 2010 Edition, by The Aluminum Association This letter certifies that the EcoFasten Rock -it System Installation Manual and Loading Tables are in compliance with the above Reference Documents. 8150 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com Page 1 of 2 DESIGN RESPONSIBILITY: The Rock -it System Installation Manual is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, the user of the Installation Manual has sole responsibility for the accuracy of the design and integrity of the system. The Installation Manual does not check the capacity of the building structure to support the loads imposed on the building by the array, such as bending strength of roof rafters spanning between supports. This requires additional knowledge of the building and is outside the scope of the Installation Manual and our review. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA 8150 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com Page 2 of 2 YINLAR ROVEN PERFORMANCE VERSATILITY Our most popular product line, the YGE 60 Cell Series, is ideal for a broad range of applications. It is proven to perform in tens of thousands of projects across the Americas, from residential and commercial rooftops to ground - 'Trusted Partner Yingli is one of the worlds largest solar module manufacturers with over 10 GW deployed worldwide, and Yingli modules are trusted by leading energy providers and financial institutions in more than 8S,000 pmjarts in the Americas. 16.0% wwnw wee. C More Energy per Watt MAXIMUM EFFICIENCY Aldft Yingli modules"deliversupeAor power output in a variety of tempeirature and irradiance NOW conditions, and self-cleaning anti -reflective coated glass reduces soiling to help 25 YEAR maximize power output. Performance is backed by our 25 -year linear warranty. LINEAR POWER WARRANTY" Designed to Outlast Tested to the industrys most rigorous durability standards, Yingli modules are PID - resistant in conformance with IEC 62804 (draft). To ensure reliable performance, Yingli O 0-3% uses quality components such as DuPont Tedlar® PVF fihn-based backsheets. POWER TOLERANCE Best -In -Class Technical Support Yngli's locally -based engineering team is trained in system design and operations to provide field -support and value-added after sales services, including commissioning and field-testing support. Our PV Testing Lab in California provides a resource for evaluating technical inquiries. Warranty Information Ten-year limited:product warranty. Industry leading 25 -year performance warranty adds value by guaranteeing power output on an annual basis, in compliance with our warranty terms and conditions. Performance Modeling For those interested in obtaining module performance modeling files for system energy yield simulation, please contact Yingli at simulation®yingliamericas.com. Qualifications & Certificates UL 1703 and UL 1703, CEC, FSEC, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007, SA8000 U wwnw wee. C t ror�. i mo Y I N G L I S O L A R .COM (PHOrOV0.LTAIC MODULE) 440D eo"omaaa s I cxa�e wwumar �'� Lo npplMm Y� 60CELL SERIES 60 / mxJpuystsl1me siGnon / Number of modules per pallet Powered by YINGLI rmapsuleM (matede0 athylene vinyl acmato (EVA) 8adnheat (material / Go" fluoropoymerbeead with EVA primer / white or black Fame (mstedel / toter) anod'aed aluminum / saver or black Junction box (ngraa protection rating) ELECTRICAL PERFORMANCE Cama (length / croesa.ctiorel area) 1000mm / 4,vW Connector (type / Ingress protection rating) MC4 / IP67 or Amphenol H4 / I1`68 Module type YL26OP-29b YL255PZ9b YL250P.29b. YL24SP.29b YL240P29b Power output Pm W 260 2SS 250 24S 240 Power output tolwonca 6P,.. % -01+3 Module e(Rdency 11. % 16.0 1&7 15.4 15.1 14.8 Voltage at P,e Vnvp V 30.3 30.0 29.6 29.6 29.3 current at P_ Lev A &59 8.49 &" &28 6.18 Opasaircuit vattage V_ V 37.7 37.7 37.6 375 373 Short-circuit currant 1. A 9.09 9.01 &92 &83 &75 STC 1000WW Irradiance, 27C cell lamparvare, AM 1.SG speca re accordGrg to EN 609043 ..Unpwatwe Irradiance YL26OP29b YL255P29b YL2SOP29b YL24SP.29b YL24OP29b 'C W/mm W W W W W High Temperature condition HRC 74 1000 203.7 199.8 195.9 192.0 180.1 Nominal Operating Cao Temperature HOOT 46 800 190.6 186.9 183.2 /79.S 175.9 Low Temparatura condition LTC 15 500 135.7 133.1 130.5 127.9 121.3 Low Irradle or Condition Llc 25 200 50.3 49.4 4&4 47.4 4" OPERATING CONDITIONS THERMAL CHARACTERISTICS UnitcInch (IRn) Max. symba "line 1000Voc Tarp shwa aodflclert of P6mo %/'C 443 Man series fuse ratiq ISA Tenperatura mafficarrt of V 16PC 432 ]8.90199 w:2i 1•�1 LJrrrWrrp reverse current 15A Tirrpeshxa melflderA of V 961'C OJIt operating temperature r.rg. -00 to 185'F (40 to 8S'Q Thr poahue aeenlcimt of V_ %M AL42 (] Men heAstone impact (dlrnat.r / velocity) 25mm / 23m/s or CONSTRUCTION MATERIALS Front cover (materiel / tiidumW k wrlrm tempered glass / 3.2rrm Call (quantity / material/ dir"aralaW 60 / mxJpuystsl1me siGnon / Number of modules per pallet 156mm x 156 mm rmapsuleM (matede0 athylene vinyl acmato (EVA) 8adnheat (material / Go" fluoropoymerbeead with EVA primer / white or black Fame (mstedel / toter) anod'aed aluminum / saver or black Junction box (ngraa protection rating) aIP6.S Cama (length / croesa.ctiorel area) 1000mm / 4,vW Connector (type / Ingress protection rating) MC4 / IP67 or Amphenol H4 / I1`68 GENERAL CHARACTERISTICS Module dlmermor s (L / W / H) 6457m (164Onvn) /3&99P R90mm) / 1.311in 0!iwn Modul. weight 40.elbs (I8.5kg) Number of modules per pallet 29 Number of pets per 40' oomsinor 28 Packaging box dlmernk" (L / W / H) 67in (1700nm)/ 4Sn (11 35mm) /46in (1165mm) Pa�keykg Isux anlglri 1232Ns (368ig) Fire claulflretlan type Type 1 and Type 2 ,&Warning Read the Installation and User Manual in its entirety before handling, installing, and operating Ytngli modules. Yngli Green Energy Americas, Inc. info®yingliamericas.com Tel: +1 (888) 686-8820 YINGLISOLAR.COM j WSENGE * YngG Green Energy Holding Ca. Ltd. I YGF6OCell5eries2015_r_N 201502 VO1 �b fpa✓�Umr� dN.� �M nn JwrimrM.,�.1.�r.�v tlmev.rd C«.psy «ia .aW, m A .n, wM�rmu mmwise YINIG SOLAR ROCK -IT SYSTem Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest to install, most secure and cost- effective solutions for installers. EcoFasten offers a wide variety of standard products as well as custom solutions, for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented conical sealing system has been in service in the snow guard and solar industry for two decades. FeaTu res Fastest, easiest to level system on the market • ETL listed to UL SUB 2703 • Class A Fire rating with Type 1 modules • Integrated electrical bonding SYSTem comPonenTS ROCK -IT MOl.. nT Array sKIrT • SIMPLE- only 3 components • Fixed wire management tray • North-South adjustability of up to 4' • Only one tool required (1 /2" deep well socket) ROCK -IT COUPLinG TwFasten Solar EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 ROCK -IT MOUnT ASSeMBLY NOTe: ITems 1-12 SHIP assemBLeD 1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS 2 Rock -It Mid -Clamp 6005A -T5 3 Compression Spring 300 Series SS 4 Tie Plate 6005A -T5 AL 5 Rock -It Shelf 6005A -T5 AL 6 Flange Level Nut 300 Series SS 7 Packaging O -Ring (Remove Prior to Installation) 8 Rock -It Pedestal 6005A -T5 AL 9 3/8" ID Star Lock Washer 300 Series SS 10 3/8"-16 Hex Tap Bolt 300 Series SS 11 5/16"-18 x .375" Hex Flange Bolt 300 Series SS 12 Rock -It -Slide 6005A -T5 AL 13 5/16" ID EPDM Bonded Washer 300 Series SS 14 5/16" x 4" 1 lex Lag Screw or 5/16"-18 X 1.50" Hex Bolt 300 Series SS ROCK -IT COUPUnG ASSemBLY NOTe: ITems 1-4 SHIP assemBLeD 1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS 2 Rock -It Coupling Mid Clamp 6005A -T5 AL 3 Compression Spring 300 Series SS 4 Rock -It Coupling Shelf 6005A -T5 AL www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 Array LaYOUT • Find the required structural attachment points. Mark these using a vertical (N -S) chalk line on the center of the rafters. • Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser bracket spacing in the E -W axis vs. the maximum spacing. Max spacing is 48" for portrait orientation and 72" for landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. • Install Rock -It Mounts to predetermined mount spacing. • The array skirt sections are the width of a typical 60 cell module - use the array skirt as a guide to lay out module placement. Note: The distance between the rows of mounts is calculated by the module dimension N -S plus 1 3/8" (35mm). Lag screw should be Installed as close to center of exposed shingle as possible. GreenFasTen FLaSHinG insTaLL 1 Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2 Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3 Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must but_ against upper row of nails to prevent turning when torqued. 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed hole in the flashing and into the rafter. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 ROCK -IT SCJ- STem inSTaLL ROCK -IT SYSTEM' Install EcoFasten Solar Flashing with Rock -It Mounts Follow GreenFasten Install instructions for flashing and bracket install on composition shingle roofs. Optimum vertical distance between lag bolts is 1318" plus module dimension. Set mounts on eave most row so that the Rock -It Pedestal is on the South end of Rock -It Slide. (ex. image 1) Set mounts on all upper rows so that the Rock -It Pedestal is on the North end of Rock -It Slide. (ex. image 6) 2 Install Array Skirt to Eave Mounts • Install array skirt starting on west side of array and move east. Attach Couplings to Array Skirt 3-4 Tighten the west most array skirt bolt on coupling tirst. When tightening the east bolt the array skirt sections will be drawn together. 5 Align and Straighten First Row of the Rock -It System with Array Skirt Use North-South adjustment of the Rock -It pedestal to straighten array skirt. Tighten screw on side of Rock -It Pedestal to secure it to the Rock -It Slide. Adjust Flange Level Nut to level the system (optional - can be leveled duri ig or after installation) 6_7 Install 1 st Row of PV Modules Slide Rock -It Mounts that are upslope down to engage top of first module Note: Make sure cable tray is facing upslope. Torque 1 st and 2nd row of mid -clamps on Rock -ft Mounts and Rock -It Couplings to 150 in -lbs. Note: Torque setting may vary according to module manufacturer. Install Balance of PV Modules 8_9 Secure wire and electrical components in built in wire tray on Rock -It Mounts and Couplings. Install next row of panels and torque mid -clamps to secure modules. Repeat install for all remaining rows of modules. 10 Level the Rock -It System • When assembly is complete, level the entire system by adjusting Flange Level Nuts. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 IGrounD nG LUG insTaLL Necessary Components: - Burndy CL50-1TN Ground Lug (UL Listing #KDER.E9999) - 14 AWG - 4 AWG Copper Ground Wire - 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS) - 8-32 Serrated Flange Nut (300 Series SS) - 11 /32" and 1/4" wrenches or ratchets/sockets 1 The Ground Lug is installed into the T slot on the Rock -It Mount. 2 Slide the Flange Head Bolton the Ground Lug into T slot on Rock -It Mount. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channel and tighten setscrew to complete assembly. IBOnDinG AssemBLY anD BonDinG PATH - Bond Path i Grounding Lug - Equipment.Grounding Conductor (EGC)- generally to earth ground Rock -It Coupling Rock -It Mount Integrated Bonding . www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 I THermaL ExPansion anD BonDnG A thermal expansion gap is required per each continuous 100' length of modules. Omit a coupling and leave a 2" gap in the array skirt and also between the modules at that point. BracKeT sPacinG Portrait Orientation — Bond Path 0 Grounding Lug %-- Goner o (EEGQ-drowsing Senaraty to aanh grWll° - Rack -it Coupling • • Rock -It Mount Landscape Orientation Maximum bracket spacing in Maximum bracket spacing in portrait orientation is 48" OC. landscape orientation is 72" OC. Spacing may vary depending upon project specific structural requirements; i,e. high snow and wind load areas may require lesser spacing E -W than the maximum. sTaGGereD LAYOUT I canTlLever ano oFFseT Staggered Mounting Points r ire i r Cantilever: Maximum cantilever is 25% of module width. For portrait Rock It Mount Rock -It Coupling orientation installations, check layout prior to installing. The array layout instructions In this installation manual offer a general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow factors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 ROCK -IT SYSTem • Fastest, easiest to level system on the market • ETL listed to UL SUB 2703 • Class A Fire rating with Type 1 modules • Integrated electrical bonding • SIMPLE- only 3 components • Fixed wire management tray • North-South adjustability of up to 4" • Only one tool required (1 /2" deep well socket) Max No. of Panels 300 Modules per ground lug Materials 300 Series Stainless, 6000 Series Aluminum Max System Voltage 1000VDC Coating Black Andodization/Mill Finish Class A Fire Rating With UL1703 Type 1 Rated Lug Specifications Burndy CL50-1 TN Ground Lug Modules (UL Listing #KDER E9999) Leveling Range 3-4° Ground Wire 14 AWG- 4 AWG Copper Per above Lug spec. Ground Wire Rock -It Slide Range 4" Max Module Size 64.96"(1650mm) x 39.05"(992mm) x 2"(50mm) Min/Max Roof Slope 5:12/12:12 Max Downforce/Uplift Rating 45 PSF Max Anchor Spacing 72" Rock -It Mount Load Rating 547lbs with Single 5/16" Lag 3.0 Safety Factor Skin: Box QTY 6 units Slide Fastening Hole 5/16" diameter Mount Box QTY 12 units Module Cantilever Lesser of 25% Width, or Module Installation Manual Coupling Box QTY 12 units Warranty 10 Yeas Material and Workman ship Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC Standards: UL 2703, UL 1703 ((TOUS 0", Ta* � www.ecofastensolar.com A aC D�EC®Fasten Solar a info@ecofastensolar.com 877-859-3947 SolarEdge Single Phas For North America SE3000A-US / SE380OA-US / MOM SE760OA-US / SE1000OA-US / SE11401 The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011690.11 compliance Superior efficiency (98°x) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre -assembled Safety Switch for faster installation — Optional — revenue grade data, ANSI C12.1 USA -GERMANY•frALY- FRANCE -JAPAN - CH:NA-ACJSI-RAIIA I-iE..NEIHE-RLANDS ItiRAE1 www.solaredge,u5 solar=ee Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE500DA-US/SE600DA-USI SE7600A-US/ SE10000A-US / SE1140OA-US SE3000A-US jSE3800A-US 1 SESOOOA-US iSE680OA-USjSE7600A-US ; SE1000OA-US SE11400A-US J OUTPUT Nominal AC Power Output � 3000 t ( 3800 � 5000 6000 7600 9980 @ 208V10000 11400 VA 1 240V Max. AC Power Output 3300 4150 5400 @ 208V 6000 t 8350 10800 @ 208V 12000 VA ( 5450 @240V { 10950 �1p 240V AC Output Voltage Min: Nom: Max!'I I 100, 183 - 208 - 229 Vac 1 AC Output Voltage Min: Nom: Max.ltl 211- 240 - 264 Vac ` AC Frequency Min: Nom: Max.1'I ' 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5) H: Max. Continuous Output Current ! 12.5 16 1 25 32 ' I 47.5 A 21 @ 240V,.,I•..,.. I 42 @ 24pV„ III GF Dl Threshold ' 1 A utility Monilor[ng, Islanding Protection, Country Configurable Thresholds Yes 1 INPUT _Yes__ _ Recommended Max. DC Power"I r V _ 3750 4150 6250 7500 9500 124DO 14250 W Transformer -less, Ungrounded Yes Max. Input Voltage 500 Vdc Nom. DC Input Voltage j 325 @ 208V /-350 @ 240V ( Vdc + Max. Input Curren"„ ' 16.5 208V 33 @ 209V 2.1 ]4.5 9.5 13 111 Cd f] Adc @_.24.0V 3015 @ 140V Max. Input Short Circuit Current 45 Adc_ Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600W Sensitivity Maximum Inverter Effidency 97.7 98.2 98.3 98.3 I 98 98 98 % CEC Weighted Efficiency t 97 @ 208V 5 @ 208V I I r 97.5 98 97. t)7.5 97.5 97.5 % 98 240V 975 �240. , gyp ..... ..... Nighttime Power Consumption_ <25 i < 4__ 1 W ADDITIONAL FEATURES _ _ Supported Communication Interfaces) _ RS48S, 85232, Ethernet, ZlgBee (optional) Revenue Grade Data, ANSI C12.1 Optional”' Rapid Shutdown — NEC 2014 690.1_2 Functionality enabled when SolarEdge rapid_ Shutdown kit is insiralledc" STANDARD COMPLIANCE Safety ) UL1741. UL16998, U1.11398, CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC partlS class.8 SPECIFICATIONS _INSTALLATION AC output conduit size /AWG range ! _6_ 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG i DC input conduit size / ff of strings AWG IA9R9 , 3/4" minimum / 1-2 strings / 16.6 AWG 3/4" minimum / 1-2 strings / 14-6 AWG Dimensions with Safety Switch 30.5 x12,5 x:7 / 30S•>< 125 z 7:5 / in/ HxWxO 775x,3I5•x172 305 x 12 5 x 10 ...5 /775x 315 x 26D 775x315x191 mm Weight with Safety Switch 1 51.2./23.2 54'.7 % 24.7 88.4/40.1 Ib / kg Cooling Natural Convection Fans (user replaceable) Noise < 25 < 50 daA Min. -Max. Operating Temperature -13 to +140 / -25 to +60 (-40 to +60 version available"') 'F /'C Range Protection Rating NEMA 3R I n For other regional settings please contact Sola rEdge support I" 6kW and lower: Limited to 135%of AC power, 7 SM and higher: Limited to 12S% for locations where the yearly average high temperature is abwe 77'F/25'C end to 135% for locations where it Is below 77'F/25'C For detailed information, refer to Iota // do triresumne �tmdr.adf A higher current source maybe used; the irwerter wig limit its Input current to the values stated l,l Revenue grade invertor P/N: SE;uoeA-US000NNR2 tst Rapid shutdown kit P/N: SE1000-RSO-St j6t.40 venion P/N: SEaaaxA-US000NNU4 solar- .• SolarEdge Power Optimizer Module Add -On For North America P300 / P400 / P405 1 04 PV power optimization at the module -level — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading - Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ifALY - FRANCE - JAPAN - ChINA - 5RAE1 - AUSTRALIA www.solaredge.us so I a r" • • SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 P300 P400 P405 _ - j ` - {for 60•cell modules)_ _ i (for 72 & 96_cell modules) (far thin film modulesl F INPUT Rated Input DC Power11' 300 4 400 405 W Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) i MPPT Operating Range B-48 8 -80 12.5-105 Vdc Maximum Short Circuit Current (Isc) 10 Adc Maximum DC Input Current 17..5 Adc Maximum Efficiency I 99S % Weighted Efficiency 98.8 % Overv_oltage Category__ _ _ _ _ 11 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED D TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage_ _ __ 60 _ 85 ; _ _ _ _ _ _ _ -j _ _Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) - - - - -- - --- -- - 5afety 0utputVoltage per Power Optimizer- -- - - - ---- -- .-- - --- .----- - 1 ___J Vdc STANDARD COMPLIANCE EMC FCC Part15 Class 6, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1(class 11 safety), UL1741 RoHS - - - - - — - _-_ Yes INSTALLATION SPECIFICATIONS - - Maximum Allowed SystemVoltage ( 1000 Vdc Pxxx_-2 series i 141 x 212 x 40.5 / 5.55 x 8.34 x 1.59 mm / in Dimensions (W x L x H) i 128x152x27.5/ �152x35/ ( 12815248/ 128xxx Pxxx-5 series i 5x5.97x1.08 I 5x5.97x1.37 5.5.97x1.89 mm/in Pxxx-2 series { Weight (including cables) 950 / 2.1 gr / Ib . Pxxx-5 series 770/1.7 I 930 / 2.05 l 930/2.05 gr / Ib Input Connector MC4 Compatible Output Wire Type / Connector ( Double Insulated; Amphenol Output Wire Length t 0.95/3.0 I 1.2/3.9 m / ft Operating Temperature Range I -40-+85/-40-+185 'C/'F j Pxxx-2 series IP65 / NEMA4 Protection Rating Pxxx-5 series, ( IP68 / NEMA6P Relative Humidity 0-100 - % ltRated STC power of the module. Module of up to 4% power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(') SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length 8 10 18 1 (Power Optimizers! Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes "I It Is not allowed to mix P405 with P30D/P400tP600/P700 in one string i" 8" NO 16 Ali 02 RAIN'9 BUSTER �o (nil �� ty • e far rar` Lfe#gym r 1 I Ultra Flexible Roof Tile Adhesive/Sealant Prt:���ant�'s Rc►�o L�:►•.�bt� �-��ac•! f3rUk►,rr r►J�a 1 ROOF TIIF 1 SHINGLES i SHEET METAL I FLASHING I VENTS 1 GUTTERS I TRIM I NEW CONSTRUCTION t REPAIRS: Roofs are on the front line in preventing water intrusion and are subjected to the most extreme wind and weather conditions. To prevent roof damage and leaks, an adhesive/ sealant must be a standout performer.. RainBuster 850 Ultra -Flexible Roof Tile Adhesive/Sealant is specified by leading builders and trusted by quality -minded contractors. to prevent roof leaks. Unlike traditional' roofing cements and mastics, RainBuster 850 offers a high-grade polyurethane formulation, permanent flexibility and powerful adhesion. When used as a roof tile adhesive, RainBuster 850 shines. as it flexes with hurricane force wind uplift, foot traffic, and seismic activity toprevent broken tiles. When applied to flashing, vents and gutters, RainBuster 850 permanently seals joints to effectively divert water away from the home. P High -Grade Polyurethane Formulation D Permanently Secures Roof Tile D` Non -Shrinking; Permanently Flexible P UV Resistant; Flexes to Prevent Broken Tiles b Withstands Extreme Wind, and Foot Traffic D Seals Roofing Joints including Flashing D Withstands Extreme Weather & Temperature D Non -Sag to Prevent Tile Slip D Adheres to Damp Surfaces, P Paintable (See :Painting Section) D Non -Flammable D VOC, GARB, and AOMD Compliant P Lifetime Warranty 'The Ultimate Roof Tile Adhesive/Sea 0 1 O Q a ic•�R�1�1,�v, � �(�'�QR.,�ra�W�tc� m o:r� � �r7a,,^�u .. �u, W, "WONNE RAIN' BUSTER DESCRIPTION RainBuster 850 Ultra -Flexible Roof Tile Adhesive/Sealant is the high quality standard in the prevention of roof leaks. Its technologically advanced polyurethane formu- lation has been specifically designed to provide roofing application solutions. RainBuster 850 performs equally well when used as a tie adhesive or as a sealant on flashing, vents, and other roof penetrations. RainBuster 850 is ideal for specifying as a multi -use roofing adhe- sive/sealant. it is ideal for both new construction and repairs. PACKAGING, SHELF LIFE & STORAGE RainBuster 850 Ultra -Flexible Roof Tile Adhesive/ Sealant is available in standard 300 ml cartridges (packaged 24 per case) and 592 ml sausage tubes (packaged 12 per case). The shelf life is 12 months. Store in a coal, dry place below 80°F for maximum shelf life. ANAILABILITYAND COST RainBuster 850 Ultra -Flexible Roof Tile Adhesive/ Sealant is competitively priced and widely available. Please contact Top Industrial, Inc. at 800-473-1617 or see www.topindustrial.com for a supplier nearest you. AUTHORIZATIONS Meets or exceeds: ASTM C920 Type S, Grade NS, Class 35, use NT,, A and M Federal Specification TT -S -00230C (COM-NBS) Type II, Class A Canadian Specification CAN/CGSB-19,13-M87 ENVIRONMENTALLY FRIENDLY • Qualifies for LEED Credit from U.S. Green Building Council: l pt EQ Credit 4.13 • Qualifies for NAHB Green Build Credits: 5 pts Global Impact Credit 7.1.3 • VOC Compliant under AQMD and CARB LIFETIME WARRANTY Top Industrial warrants this adhesive to perform as described on its package and associated data sheet for a period of 100 years from the date of purchase. See next page for further warranty details. Ultra Flexible Roof Til _p.-oP�ot,fti ° Adhesive/Sealant Field Proven to Prevent Roof Leaks a TILE -TO -TILE DOND/NO RainBuster 850 is ideal for adhering roof tile -to- , tile in valley, ridge, hip, rake and general roof the installation. Secures cut tiles when mechanical fasteners cannot be used. RainBuster 850 provides additional protection, against wind uplift, seismic 49 activity, and tile damage. Prevents file chatter. ID RainBuster 850 seals nail entry points created - } during file Installation. RainBuster 850 flexes to day bonded and prevent broken tie and roof leaks. FLASHING LAP JOINTS RainBuster 860 Is Ideal for paling varied lap joints where two lengths of flashing meet such as In valleys. RainBuster 850 flexes to maintain a permanently bonded watertight seal For best results, apply a continuous 1/2" bead to both the inside and outside of the joint. Tool the outside joint bead as necessary (see application and tooling sec - tons). Available in the multiple colors and paintable (see painting section). RainBuster 850 is ideal for use where flashing terminates at walls and chimneys. RainBuster 850 provides outstanding adhesion to both metal and common exterior wall surfaces. RainBuster 850 flexes to maintain a watertight seal. For best results, apply a continuous 1/2" bead to both the inside and outside of the joint. Tool the out- side joint bead as necessary (see application and tooling sections). Available in the multiple colors and paintable (see painting section). VENTS AND CNIAMEIV CAPS P&Buder 850 seals joints in vends, chimney caps and other roofing envelope penetrations. Also secures vent structures to underlying baps. RainBuster 850 flexes to maintain a watertight seal. For best results, apply a continuous 112" bead to both the inside and outside of the joint Tool the outside joint bead as necessary (see application and tooling sectorial. Available In the multiple calors and paintable (see painting section). Gmftw Seals seams in gutters. gutter assemblies, and downspouts. 0orperrXw&WSNWw Adheres shingles and supplements mechanical fasteners. S 40W Permanently seals seams and %stoner a" holes. IpAGSupplements mechanical fasteners and seals seams. Can significantly reduce vibration noise. Seals tears in felt and underlaymerd. Bridge entire tear and tool as necessary. OW SWOm Int 6g ol:Adhen:s to to damp sudaces Remove standing water prior to application. Top Industrial, Inc. • 15010 Keswick St., Van Nuys, CA 91405 • 800-473-1617 • www:topindustrial.com APPLICATION: Easy to apply with conventional caulking equipment. Application temperature range: 20F —120F. If application air temperatures are below 40F, con- dition product at 70F prior to using for best results. Cut tip at a 45 -degree angle. Location of cut will determine desired bead thickness. Puncture seal. Apply sealant to joint. Typically, minimum 3/8"-1/2" beads should be used for proper bonding and sealing. Fill joints in continuous beads from deepest point and avoid overlapping of sealant to prevent air entrapment. Adhesive/sealant should wet the joint wall surfaces. With lap joints, apply adhesive/sealant to both inside and outside of joint for best results. Adhesive/sealant provides 1-3 hour working time before skinning. Adhesivelsealant cures with exposure to normal atmospheric moisture with full cure in 1-3 days depending on humidity. May be used on damp surfaces; take steps to remove standing water. For best results, use opened cartridges and sausages the same day. APPROPRIATE SURFACES- RainBuster 850 is appropriate for use in new construction and repairs on a wide range of common roofing materials including concrete, clay, slate, cornposigon, fiber-cemero, asphalt saturated shingles, masonry, mortar, metals Including galvanized, aluminum, and copper, underiaymerd and felts, plastics including PVC, vinyl, fiberglass, nail% and wood. PREPARATION: For best adhesion results, surfaces should be dean, and free from dirt, dust, oils, release agents, standing water, old sealants, or other contaminants. Dust and loose particles should be blown off surfaces. FIELD PRETEST; Due to the varied nature of construction substrates, field-test adheslvelsealard on actual surfaces prior to beginning work User must determine 0 results including adhesion are acceptable. TOOLMfh t required, Wng is recommended within 20 minutes alter application. Tooling should be done in one continuous stroke. Techniques using solvents or soaps are riot recommended. it masking, remove tape Immedlately after tooling. CLEAN UR Clean hands safely with RainBuster Top Towels (citrus wipes). Mineral spirits and other commercial solvents such as xylene, toluene, or methyl ethyl ketone (MEIQ_ may be used to clean up excess smears and tools. The use of solvents may be hazardous to your heath. Keep away from open flame and use In well -ventilated area. Follow solvent manufacturer's instructions. Cured adhesive/sealant is difficult to remove and must be done se by abrasion or other mechanical means.. PAINTING OVER RAINBUSTER 850: For best results, apply paint over RalnBuster 850 adhesive/sealant 72 hours atter application. High quality 100% acrylic paints and primers are recommended: Many roofing specific spray paints are acceptable. Avoid the use of oil base paints as they may exhibit a slow/non- curing condition when in contact with adhesive/sealant Palyd when weather and temperature conditions meet paint manufacturer requirements. Feld pre-test for suitability of paint and painting process is required. Contractor must determine suitability. Consult Top Industrial for further information. MAINTENANCE No maintenance should be needed. If adhesive/sealant becomes damaged, remove damaged portion. Clean surfaces in damaged area, and repair with fresh RainBuster 850. PRIMING PRIOR TO APPLICATION: Generally, priming is not required. If adhesion pretest is unacceptable, consult Top Industrial for recommendations. APPLICATION OVER GLAZED, PRE- PAINTED, OR PRE -PRIMED SURFACES:- Glazed, URFACES:Glazed, pre -painted and pre -primed surfaces typically do not have the adhesive quality or flexibility of Ra)nfluster 850 adhesive/sealarr Lack of adhesiva(sealant contact with raw substrate may inhibit ability to maintain bond and seal. Glaze, paint or primer may pull away from raw substrate with johd movement. USE WITH ASPHALT BASED SELF - ADHERED FLASHING (A.K.A. SBS modi- fied asphalt & bituminous matedaD: When used appropriately, RainBustar 850 can be used successfully with asphalt - based flashings. Unlimited contact is acceptable between adhesive/sealant and the permanent polyethylene/plasUc- based facer side of self -adhered: asphalt flashings. Steps must be taken W minim contact with the adhesive side of asphalt flashings. Plasticizers, in adhesive/sealant may accelerate the normal moistening and softening of asphalt that occurs with.heat. Do not apply adhesive/sealant directly to adhesive asphalt side of flashing. Do not apply adhesive side of asphalt flashing. directly over adhesive/sealant. Remove excess sealant prior to application of adhesive asphalt side of flashing: User must determine suitability through field pretest Consult Top Industrial for further information. LIMITATIONS: Suitability for each intended use must be determined by the user using the Information found,in this data sheet and an application pretest • Not for use over standing surface water or surface frost. • Not designed to replace use of mechanical fasteners. • Not for use where subjected to constant water immersion. • When painted, user must determine paint suitability. See"Painting" section for detailed limitations. • When used with asphalt -based setf- adhered flashings, user must determine suitability through field pretest See 'Use With Asphalt" section for detailed limitations. • Do not cure in presence of curing silicone sealants. This may interfere with RainBuster850's•cwing process. • Avoid sealant contact with solvent cleaners during cure. This may interfere with RainBuster 850's curing process. PRECAUTION: Combustible vapor. Uncured sealant may cause allergic skin reaction and eye, skin andrespiratory tract Irritation. Keep away from sparks and flame. Avoid contact with eyes, skin and clothing. Avoid prolonged exposure to vapors. Use only with adequate ventilation. Wear protective dating during handling. Wash thoroughly after handling. KEEP OUT OF REACH OF CHILDREN. See material safety data sheet before use (contact Top Industrial or distribuWr): FOR CONSTRUCTION AND INDUSTRIAL USE BY QLUUJFiED CRAFTSMAIL FIRST AID: lt inhaled, removetW fresh air. N breathing is difficult give oxygen and call a physician. In case of contact with uncured sealant, immediately flush eyes with water for at least 15 minutes and wash skin with soap and water after using RainBuster Top Towels (dins wipes): Call a physician 0 irrttabon persists. See material safety data sheatfor more detail. LIFETIME WARRANTY DETAILS: Top Industrial, Inc. warrants this sealard/adhe- sWe to perform as described on its pack- age and associated data sheet for a period of, 100 years from -the date of purchase. Upon proof of purchase, Top Industrial's sole liability, expressedar implied, shall be to replace sealant/adhesive proven defec- tive and is limited to the stated selling price. This warranty is not transferable from the original purchaser. In no event shall Top Industrial' be liable for conte querrgal� or incidental damages, resulting from the use of its sealant products. RAIN� BUSTER The Ultimate Roof Tile Adhesive/ Sealant Ultra Flexible Roof Tile Adhesive/Sealant Prevents Roof leaks and Broken rile ROOF TLE I SHWASS I SHEET META. I RASING I VOM I GUTTERS I TRIM I NEW CONSTR11=101 REIPA IS o BUSTER PHYSICAL PROPERTIES Skin Time..........................................................1-3 hours Cure Time...........................................................1-3 days % Solids.......................................................96% to 99% Paintable.........................................Yes — See limitations Sag or Slump...........................................................None Clean -Up Citrus Cleaner Coral Terra Cotta Tan Gray (Stone) Bmwn Black Shrinkage....................................................................NII (Bmw) Chalking or Crazing ......... ......... :........ .... .........Nil TYP/CAL PERFORMANCE CHARACTERISTICS After 7 days cure at 77 deg. F and 50% RH Hardness (Shore A): ................................ 32 ASTM D 2240 900 ML CAMIDGES Tensile Strength ......................Up to 250 psi ASTM D 412 APPROXIMATE LINEAR FEET PER CARTRIDGE Elongation.._.....................................1400% ASTM D 412 BEAD WIDTH, INCHES Adhesion in Peel ..................................................>33 plw �/p 1/4" 3/8" 1/4" 3/4" 7/8" 1" ........................................... T S-00230C/ASTM C 794 .. 1/8" 49.6 33.1 24.8 20.0 16.5 14.2 12.4 Stain "Colo' '"e­­* hange................................................None 1/4- 24.8 20.0 12.4 10.0 8.3 7.1 6.2 • ....• ,*••••••••••• ................TT-S-00230C/ASTM C 510 Ozone Resistance .................... Excellent " 3/6 — 11.0 8.3 6.6 5.5 4.7 4.1 ' Joint Movement Capability......................................±35% 1/2" — — 6.2 5.0 4.1 3.5 3.1 ASTM C719, 73°F cure / 73°F cycling W Resistance ........................Excellent - ASTM C 793-75 Water Resistance ................................................Excellent rowdly 1n -in tPhe USA t- BIF. For more than 25 years, Top Industrial's RainBuster I has been trusted to prevent leaks in the building elope and squeaks in floor structures. Today that rst runs deep - RainBuster is specified by the ration's leading builders and trusted by scores of respected contractors. The reason for the trust is simple... s RainBuster products and services outperform other brands in preventing leak and squeak related call-backs. s �a t- Product Data Sheet DU222RB Safety Switch, 60A, 240VAC, Non -Fusible, General Duty, 2 -Pole Technical Characteristics D ;�tsc3uiv��a bvSchneider Electric List Price $353.00 USD Availability Stock Item: This Item Is normally stocked In our distribution facility. Wire Size #10 to #2 AWG(AI) - #14 to #2 AWG(Cu) Action Single Throw Ampere Rating 60A Approvals UL Listed File Number E2875 Enclosure Type Rainproof and Sleet/lce proof (Indoor/Outdoor) Enclosure Rating NEMA 3R Factory Installed Neutral No Ma>amum Voltage Rating 240VAC Disconnect Type Non -Fusible Terminal Type Lugs Mounting Type Surface Type of Duty General Duty Number of Poles 2 -Pole Shipping and Ordering Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule DE1A GTIN - - _ - - 00785901491491 _ Package Quantity 1 Weight 4.7 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y Country of Origin MX As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. 02009 Schneider Electric. All rights reserved. Schneider 'Electric