Loading...
BSOL2015-023178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&t�p 4 4v Q" COMMUNITY DEVELOPMENT DEPARTMENT 'BUILDING PERMIT Application Number: BSOL2015-0231 Property Address: 52995 AVENIDA RUBIO APN: 773312026 Application Description: SALGADO/7.5kW PV SYSTEM - (34) 255W PANELS/(2) INVERTER Property Zoning: _ Application Valuation:* $17,000.00 Applicant: T A K ELECTRIC INC L:? I 1654 ILLINOIS AVENUE STE 18 PERRIS, CA 92571 1654 ILLINOIS AVENUE STE 18 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C10 License No.: 947912 i Date /Ox d �( �� Contractor ~— OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit -to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon; and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097; Civ. C.). Lender's Lender's 11111111111111111111 66 VOICE.(760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/2/2015 Owner: MARTIN SALGADO 52995 AVENIDA RUBIO LA QUINTA, CA 92253 I _ Contractor. L:? I T A K ELECTRIC INC _ 1654 ILLINOIS AVENUE STE 18 r_y� PERRIS, CA 92571 (951)319-9235 �- Llc. No.: 947912 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' COT-12211sation, as provided for by Section 3700 of the Labor Code, for the performance fo k for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Vion 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. 1 �% ate: ' Applicant'�— WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and (shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: od Signature (Applicant or Agent/zn� �� ~ DESCRIPTION FINANCIAL • ACCOUNT /• Y AMOUNT PAID' PAID DATE BSAS SB1473 FEE 101-0000-20306 $1.00 EO $1.00 12/2/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY PERMIT SERVICE INC CHECK R11268 16073 SKH Total Paid for BUILDING STAN DARDS.ADMINISTRATION BSA: .$1.00, $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $24.17 12/2/15 PAID BY METHOD ' . RECEIPT W CHECK # CLTD BY.. PERMIT SERVICE INC CHECK R11268 16073 SKH DESCRIPTION ACCOUNT :QTY AMOUNT PAID ' PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 12/2/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY PERMIT SERVICE INC CHECK R11268 16073 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE.`. PV SYSTEM - MISC EQUIPMENT 101-0000-42403 .0 $24.17 $24.17 12/2/15 PAID BY ' . METHOD RECEIPT # CHECK # CLTD BY PERMIT SERVICE INC CHECK R11268 16073 SKH DESCRIPTION ACCOUNT QTY. AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17 $24.17 12/2/15 PAID BY METHOD -RECEIPT # .. CHECK # CLTD BY PERMIT SERVICE INC CHECK R11268 16073 SKH Total Paid for ELECTRICAL: $96.68 $96.68 DESCRIPTION ..ACCOUNT. QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 12/2/15 PAID BY .METHOD RECEIPT# CHECK# CLTD BY PERMIT SERVICE INC CHECK R11268 16073 SKH Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: Description: SALGADO/7.5kW PV SYSTEM - (34) 255W PANELS/(2) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 11/19/2015 MFA Approved: 11/30/2015 LUR Parcel No: 773312026 Site Address: 52995 AVENIDA RUBIO LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 170 Lot: 13 Issued: UNIT 17 NOTES Lot Sq Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $17,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 7.5kW SOLAR ARRAY - (34) 255W TRINA SOLAR PANELS W/ (2) ABB PVI-3.8-OUTD-S-US-A INVERTER. 60AMP LOAD CENTER. [288SF] 2013 CALIFORNIA ELECTRICAL CODE. ADDITIONAL SITES CHRONOLOGY TYPE STAFF NAME, ACTION DATE CHRONOLOGY COMPLETION DATE NOTES PLAN CHECK SUBMITTAL RECEIVED MARY FASANO 11/19/2015 11/19/2015 TELEPHONE CALL LUIS URIBE 11/30/2015 11/30/2015 LEFT A MESSAGE FOR KEVIN. PERMIT IS APPROVED AND READY TO BE ISSUED. CONDITIONS NAME TYPE NAME ADDRESSI CONTACTS CITY STATE. ZIP PHONE FAX EMAIL APPLICANT T A K ELECTRIC INC 1654 ILLINOIS AVENUE STE 18 PERRIS CA 92571 (323)333-5138 CONTRACTOR T A K ELECTRIC INC 1654 ILLINOIS AVENUE STE 18 PERRIS CA 92571 (323)333-5138 OWNER MARTIN SALGADO 52995 AVENIDA RUBIO LA QUINTA CA 92253 (323)333-5138 Printed: Wednesday, December 02, 2015 4:33:08 PM 1 of 2 SYSTEMS BOND INFORMATION Printed: Wednesday, December 02, 2015 4:33:08 PM 2 of 2 CN?EAJF sysrrMs INSPECTIONS FINANCIAL INFORMATION PARENTPROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE NON-STRUCTURAL - LUIS URIBE 1 WK DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 12/2/15 R11268 16073 CHECK PERMIT SERVICE INC SKH Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0. $24.17 $24.17 12/2/15 R11268 16073 CHECK PERMIT SERVICE INC SKH .FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $24.17 12/2/15 R11268 16073 CHECK PERMIT SERVICE INC SKH FIRST 20 PC PV SYSTEM -MISC 101-0000-42403 0 $24.17 $24.17 12/2/15 R11268 16073 CHECK PERMIT SERVICE INC SKH EQUIPMENT PV SYSTEM: MISC 101-0000-42600 0 $24.17 $24.17 12/2/15 R11268 16073 CHECK PERMIT SERVICE INC SKH EQUIPMENT PC Total Paid for ELECTRICAL: $96.68 $96.68 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 12/2/15 R11268 16073 CHECK PERMIT SERVICE INC SKH. Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: BOND INFORMATION Printed: Wednesday, December 02, 2015 4:33:08 PM 2 of 2 CN?EAJF sysrrMs INSPECTIONS PARENTPROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE NON-STRUCTURAL - LUIS URIBE 1 WK 11/19/2015 11/30/2015 11/30/2015 APPROVED BOND INFORMATION Printed: Wednesday, December 02, 2015 4:33:08 PM 2 of 2 CN?EAJF sysrrMs Bin # Crty of La Quinta Building u Safety Division Permit # 78-495 Calle Tampico r �I(�`Ci La Quinta, CA 92253 - (760) 777-7012 lam" Building Permit Application and Tracking Sheet Project Address: -S,? -lei A&n /`fin t O Owner's Name: A. P. Number: Address: 5')e5q Legal Description: Sir D City, ST, Zip: 04 Ci.) S S 3 lnl n Contractor: A �: � c.� G hC. Telehn• P 0 C. SDI 33 51-3 Address: �%vS� I ��4 n o t_S kms. / Project Description: City, ST, Zip: -P1V4V•S 64 �'� J� �S1 de l �^•1 �`�-tyA v�'1 �- d Telephone: 5.3 9a3 V t J s � S ct S State Lic. # : �l et 1 City Lie. 3t.4 Arch., Engr., Designer: Address: City, ST, Zip: Telephone: cY• Co structi nTY P e: SOccupancy: Lic.#. New Alter Repair Demo Project Pecir le one): Name of Contact Person: �v�� WA)r�L/e� Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: l,'l4 ($ -q�fJ Estimated Value of Project: 000 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2qd Review, ready for. corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"! Review, ready for correct ionstiissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue Schodl Fees, Total Permit Fees c sunGEVITY' GENERATE POSITIVE - _Y INC. 6Ti rKANKUN 5T SUITE 310 OAKLAND, CA 94607 DIRECTORY LABEL PER NEC 705.10 POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN LOCATION OF MAIN SERVICE ENTRANCE LOCATION OF AND UTILITY METER INVERTERS WITH INTEGRATED DC DISCONNECT 5y:UrHWI: Uale:—Location: Salgado -2144634 SVISheet Size: 11%17 MT m DRIVEWAY N CITY ® LA (JUIN PT. BUILDING & SAFETY APP F CT ION FOR / DATE j� l BY �✓ 11111111111111111111,1 T.A.K. Electric lyd TAX CSLB #947912 C-10 (951) 970-315p—k,�N,, I Ktst UKAVVINUS, SrtGIrICATIONS, AND DESIGNS ARE THE PROPERTY Ur SUNUtVI IT ING. NU rAK I —U. est UUrltu UK Ustu run Un VVI IN MY U I ntK VVUKK U I KtK I MAN I Mt: SrtUIeIU rKUJCN rUK wnWK I Ne I-- UMCN utV tLvrtU rrn NVU I UUn VVKI I I tN 1 THE Univ As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We ore committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited www.trinasolar.com Trinasolar Smart Energy Together MODULE Our most versatile product • Compatible with all major BOS components and system designs • 1000V UL/1000V IEC certified One of the industry's most trusted modules • Field proven performance Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certification requirements • PID resistant ®Certified to withstand challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty 6180% a Addition YOIu e frorn Trina a 90% Sol or'slit? eorWorronly co a 0 80% Years 5 10 15 20 25 ■ Trina standard Industry standard THE Universal MODULE PRODUCTS POWER RANGE TSM-PD05250-265W Peak Power Watts-Rmx(Wp) 245 250 255 260 TSM-PD05.08 Power Output Tolerance -P -x (%) 0-+3 250-265W TSM-PD05.05 Maximum Power I 245-26OW DIMENSIONS OF PV MODULE unit:mm 941 Back Vlew m 35 I A -A I-V CURVES OF PV MODULE (260W) ELECTRICAL DATA (STC) Nominal Operating Cell Peak Power Watts-Rmx(Wp) 245 250 255 260 265 Power Output Tolerance -P -x (%) 0-+3 -0.41%/°C ^� Temperature Coefficient of Voc Maximum Power I Temperature Coefficient of Isc 0.05%/•C 8.20 8,27 8,37 `Maximum Power Cutrareni l -P (A) 8.50 8.61 I f� Open Circuit Voltage-Voc (V) 37.8 38.0 1 38.1 I 38.2 38.3 EShort Circuit Current-Isc (A) 8.75 �# 8.79 8.88 JI 9.00 9.10 1 Module Efficiency qm I%) i 15.0 fi 15.3 15.6 15.9 16.2 STC: Irradiance 1000 W/m2, Cell Temperature 25°C, Air Mass AM1.5. o Typical efficiency reduction of 4.5% at 200 W/m2 according to EN 60904-1. to 0 ELECTRICAL DATA (NOCT) f Maximum Power-P-x(Wp) I 182 1 111 186 190 193 I 197 Maximum Power Voltage-Vwp (V) 27.6 28.0 28.1 28.3 28.4 1 Maximum Power Current -I ,rP (A) 6.59 6.65 6.74 6.84 I 6.93 I Open Circuit Voltage-Voc (V) 35.1 ., 35.2 35.3 35.4 11 i 35.5 { o Short Circuit Current-Isc (A) 7.07 t 7.10 7.17 7.27 7.35 NOCT: Irradiance of 800 W/m2. Ambient Temperature 20'C, Wind Speed I m/s. MECHANICAL DATA Solar cells I Multicrystolline 156 x 156 mm (6 inches) ICell orientation4 60 cells (6 x 10) Module dimensions 1650 x 992 x 35 mm(64.95 x 39.05 x 1.37 inches) l Weight 18.6 kg (411b) t Glass 3.2 mm(0.13 inches).High Transmission, AR Coated Tempered Glass - Backsheet White(PD05&PDO5.08): Block(PD05.05) I r 7� Frame I Silver Anodized Aluminium Alloy (PDOS): Black(PD05.08&PDO5.05) b t EJ -Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.Omm2 (0.006 inches2), 1000mm(39.37inches) Connector MC4 Compatible 4 10 EO >0 d0 5• vmaaHvl CERTIFICATION CE -@_LISTED PV''d CLE v Trinasolar Smart Energy Together TEMPERATURE RATINGS Nominal Operating Cell 44-C (+2°C) Temperature (NOCT) ITemperature Coefficient of P. -0.41%/°C ^� Temperature Coefficient of Voc 0.32%/•C Temperature Coefficient of Isc 0.05%/•C WARRANTY 10 year Product Workmanship Warranty 125 year Linear Power Warranty j (Please refer to product warranty for details(' PACKAGING CONFIGURATION Modules per box: 30 pieces Modules per 40' container: 840 pieces MAXIMUM RATINGS Operational Temperature 1-40-+851C Maximum System 1000V DC(IEC) Voltage 1000V DC (UL) Max Series Fuse Rating I I5A a f Z CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 172015 Trina Solar Limited. All rights reserved. Specifications included in this dotasheet are subject to change without notice. �r w ,g r :. - . n _ '- j » ?r. 'tis .�•a , ^.i ' •r'sY,� 'S . • `:f .,7 •.. 4 f • f'v• y •r,: • .. .Ar,• A. . < y , f .c Pu _ pryG U 9 ,T N : . Et It LER I -FI C.A TE.O-F C1OM­.1 fTI .Number :' 20140630-E30.. 651:5- . ' :,; . •,+toma. 'r' _ 0 065110630-E3Cerfcae .: ' : ti I. . 2 02E3065151 12.1 ,: • m :rr'lR.ssefuer>enact ea s :2Ece0310.6515-20121T2' 1,3'orReferen4-JUNE-30,NE_ 0:.e.DosseD f .. >y. :. +.' . r , g� W. iiS': -0., aj i it t'4}' +k. a j• t* A . •',EFJ ...... .. # ` .� � ...:.... .. �.',• • ,• � `�..., ,:� «, w:.� :ri ,= eeif�ied?':cons,t'ructon: as..below; ma r be ma'r.ked, ith. i•ts:''t : e + ' .: r :... The. modules, . ith ..t e, sg. �. Y YP. Issued to.. TRINA S.O.LAR. LTD ; .•:�' �.:.... �? forUL nice° be10 table... tr..•.. � �.,.,�',.' �:- � '.�` ;�.. is'ted°ire er.for ma �o�ducts$�onl a�sthe.��r... ..' 2 TIAN HE RD ELECTRONICS -PARK -NEW DISTRICT• • �'` � - ' �a'' ' �:�'�' '�` ' � ;,•'� �.,.�" '���»��'��': ;�� a . r�. $, ' �. ,° •� . ,'',, ,- CHANGZHOU,�JIANGSU:2.13Q31. CHINA, NO. . . � p ��t F� U. Xk �{� i�:�i' �• !R!'': ':.' • .fi -t_ ,mts'+,mak. �$" ' This.is..to cern that . PHOTOVOLTAIC •-4144.. � = LEIsi `AND.PANELS.WITM MODU S. I U731111 S ®r r resentative sam les of - e SYSTEM • P P III �T • V LTAGE RATINGS OVER' 600 VOL S O � a. $. Utx in 4.' . S -Refer to�addendum,• a eJORIVIodels < �F'{y •tmoi 4 � •4h - +f: "N �•a T 1 r .. :'�. !' 4t' #¢ "..�' i . t F � n 1 imn ; :: n..�35' ros sectio a d esio C s x 35mm,. a A �l L- Faiavebeen'-inve'stl atedb UL m' accordance with,,th < r Standard(s) _ 404 indlcated:on'.'this Certlflcate.F. Thi kness. 1.5 • _ .�,.:,�... VrR «> '�^t, hi y,. �>�� y ,m0. q _�. •.cy . :� . _.. Y n � - x'P 14 : �`' TSM_ xx D TSM axxP'D14 ,08 1r ., t r •; -r ' r' f :' = L 1x7.03= -t Standards fo Sae U O. tY Standard'$for Safet for. Flat-Plate>Photovoltaic. ' _ Y .. L O RD/C1703 01 Flat Plate: ' 11/lodulesand ,.p Panels and U C t a • ` '.Pho of voltalcModules and. Pane,' , i m i �. .t,, . �:- ..ice Additional lriformation:` S,ee.t h ' � e. U .. - x..R.. � r: .:, L Onllne'•Certifications Dlrecto • ry x ,:. :u - . *�. ul com/database •::-,. > .for, additional; information .. .'www. , _ •J $1 t w' 4" T' T. P- k + a ,M tt ' 4 . 1_� 5 >Onl those roducts beans the UL -Listen Mark fort : Y • � hd Canada should be conside ed as a US an ] USS+"' � bemgtcovered<by ULs;;Listmg andsFollow Up-Service�meetmg3the F" and 'Canada :. , ^ The:UL Listen ';Mack for the US and Canada generally 9.. 9 appropriate'requirements'for + . includes: the ULPin ailcircle s mbol-with#°.C'' ' Y Y..- r %Nand US"'identifiers:,°0 --, he word, -LISTED - a controi'number3(may<be'aipha,numenc)'assigned' „ s. 1, by UL; and,the product category name (product identifier)„as;mdicated ,ggDirectory: .igx{ �� �.. • • ... ,.4fo h = r riate UL _r7 U Int a app op qx - k L r h :UL+Listen Mark on the' roduct:. 00 the »m - r r 4 '1� , ^ ate�+''t. r. Module model TSM=xxxPD05, ,: �'” «TSM=xxxPD05 t#Substrates'"0 s t S eci•f`i"c construction ... ii +q. •�y �p �} SNF •q� fiF :tF ` F' 's• Su erstrate 32 4�3.6mm"'�'thick, P p a VA'. 5�:0��6�lmmthck *�t` 3'0mm 0*6:mmT.e iy t c r ' i 4•: hi k eFL F m,, e n ss�. `7. ion=> 35� Gross sectional d „ +. 35 # 2 H9ht� 35 kk 'Thickness.'�T�"�5mm Mar.kin'g .. $ .... �, ��?Rt �i �� # '9 : m.n - Modu"i,�eEire�,�� , Peruformance 'N4 t {y 4 ' 1+1 r � fSM xxiR1505 :: : tt :.. 1 - xxx,PD05 Su -e:rstra%te 3-:'2.:4:: 36mm' thiyck,' : A M1p ,r hr'> k EVA 0 250 r6.1mm t c ,, , - Module NF -re ' n , Performance•:. t OIL,t A05, TSMxx�xPD050:8 :•.. � fix,. , Substarate,284mm 0 30 mm ::: •. �. �,... Framer.'.' :: .. Type2 x: ,�' �' •:` �: �::. �.. t F � n 1 imn ; :: n..�35' ros sectio a d esio C s x 35mm,. a A �l L- n s :.. .,'�' �:_: �'• ».:, »'• , k..�,�,. .eR,..,.. '+*.. Thi kness. 1.5 • _ .�,.:,�... VrR «> '�^t, hi y,. �>�� y ,m0. q _�. •.cy . � - x'P 14 : �`' TSM_ xx D TSM axxP'D14 ,08 i A. k - Su e�r`strate: 3.2 .4..3.6mm t c _ P EUA t.O� 25 :0 6' thick a r '« 0::2&.4' mm0.-mm ,"tet. - Module FirefE Per._formance Y1? �: J.' <t'hi k y< c OPT 4t ITIII .. .. Frame. Cross .:sec't>o,nal .dimension':.., �.. i �C e Y AMM �+. �x �:4� _ 0 35 mm 4 H t. T:4Omm , h. ] mm. ' ass t Q�tl IT 9 4. r' h .. ,F ..S A '7 F = XXPD i A TSM X 05 0 `moi A M XXX•PDOS 1�8 n 'tii k Su r r 3 2 4 3+6mm t c e st ate r : ' U mm th-ick. E A 0 25 0 65 sate'. 0 02=5:. 0284. Sub'tr F t Module Fre,a�' �. c . .. P rformance � e . t �o •: th k •�:� 11C i r.'C It =i''nal. dimension. 0 - oss sec 3 x Hai h't , , ;Wi11Iam R, Came ?Dlrector,:NoM American Certl9catlon Programa . i <- WIIIIam R Camey; Director, NoM American Certl9cmlon Programa 7t - g y etc: � , :, � :A _,�_ _ ,�. fit}'=:F" vi#+.+ "1�iB'.. "a�>. �:• '. ,4' }�'. ... 1� �;� .:' .. pF;. tiyr}"' _ "p±rr' titsz, . fiz'" ' p.t; P • �, ' ,>�.. s • ..t,,UL LLC .c'xY' �t . '� U .For questions. lease - " :>• ' ':.. i •' .. * - -Ah Infortnatlon antl tlocumentagon InvoNln UL Mark services arc provided on behalf of UL LLC (UL) or any oulhorized licensee:!? UL. For question"; please " ",;: + , .' - •' Any.lniortnallon and docurt,entation Involving UL Mark aervlces,are provltled'on_ Dehal/ of UL LLC,�UL) or any.aulhorized licensee of L q . P .. .- .. , - r Y r, .,. ....9 -.y "" - ;G `"" "°" """ ti "•': " ''%` ".' :' " - : L' - . " • - ' contact a local ULC •tomer Seivlce Re` iesenlalive at www:ul:com/contactus : . " "�A` 7 -•:, : contact a local UL Customer Service Representative.,. yc''. •ry 7}*, , , v t : " Lt i .. Page 1:of'q. :XOt.' - . .: - 4�•, _ : - This family of single-phase string inverters complements the typical number of rooftop solar panels enabling homeowners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions, or unbalanced strings (for example: East and West). The dual -input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high - efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0 percent. The wide input voltage range makes the inverter suitable to low-power installations with reduced string size. This rugged, outdoor inverter has been designed to be a completely sealed unit, to withstand the harshest environmental conditions. Highlights: — Single-phase and three-phase output grid connection — Wide input -voltage range for increased stringing flexibility and energy harvesting — The high-speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions — Integrated DC disconnect switch in compliance with international Standards (-S Version) Power and productivity „ 1111 for a better world TM AM 1919 Additional highlights RS -485 communication interface (for connection to laptop or data logger) Available with the optional VSN300 Wifi Logger Card for easy and affordable wireless monitoring Compliant with NEC 690.12 when used with ABB's Rapid Shutdown device Comes standard with DC Arc Fault Circuit Interruptor (AFCI) to comply with NEC 690.11 Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US 2 ABB solar inverters i Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD Block diagram of PVI-3.0/3.6/3.8/4.2-TL-0UTD ---------, ------------------------------------------------------------------------------ INl.11a)� MPPTI INVERTER ;--tI (DV00 SLRULCAPS LINE GRID PARALLEL IN111aIIWla �� FILTER RELAY 'INI INI , ,INI INI , , � INI INI � I IN - DC - - - - `----, 1 AFDI - , ' r -----r---, ' T IIl{la (I)COO IN1N211DI)UDJO I , 1 a 1 a a d a 1W , RESIDUAL CURRENT DETECTION ' IN] INl , IN3 INI , ' ' IN2 P, STANDARDVERSION -AVERSION -S VERSION '----------------- -----''----------- ,a. _ DCMC ,. , DVAC REMOTE CONTROL•' uOSP. DSP ' R [ONTR COMB GROUND 0 Np- ;R —1 � omEcTI. ALARM N.0 N.O CONTROLORCLOT C ----------------------------------------------- Remote control function not available on -A version PVk4.2-OUTD-US 97 96 I f w 93 92 9,—I 0% 10% 70% 30% 40% 50%. 60% 70% 80% 90% 190% % ol Rated Output Poway Technical data and types Type code HxW PVI-4.2-OUTD-US s,s xo .s.nmwm •m w PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US 7 Jnlppingweight....................................................................................................€..................................................................................... �..t)UID.(.!.:UK91'.................................................. Mounting..system............................................................................................................................... Wall bracket Trade size KOs (tea x 1/2") and Zea x 1-1/4", 3 places side, front Conduit connections2 Side: (2) plugged 3/4" openings, (2) Concentric KOs 3/4", 1" Safety and EMC standard arc All data is subiect to chanoe without notice ers 3 CSA S � Group Certificate of Compliance Certifi cate: 2708406 Project: 2722409 n, WI 53151 USA Master Contract: 259813 Date Issued: April 24, 2014 Issued to: ABB, Inc. 16250 W. Glendale Drive New Berli The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only.icp Issued by: Jocelyn Jens Product Group Coordinator C US Authorized by: Lindsay Clark Operations Manager PRODUCTS CLASS 5311 09 -POWER SUPPLIES -Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES -Distributed Generation -Power Systems Equipment - Certified to U.S. Standards Utility Interactive Invert er, Models PVI-4.2-OUTD-US, PVI-3.8-OUTD-US, PVI-3.6-OUTD-US, PVI-3.0-OUTD-US, PVI-4.2-OUTD-S-US, PVI-3.8-OUTD-S-US, PVI-3.6-OUTD-S-US, PVI-3.0-OUTD-S-US, PVI-4.2-OUTD-S-US-A, PVI-3.8-OUTD-S-US-A, PVI-3.6-OUTD-S-US-A, PVI-3.0-OUTD-S-US-A, PVI-4.2-OUTD-US-W, PVI-3.8-OUTD-US-W, PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W; provided with two DC input channels, permanently connected, system ratings as follows: Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including "—Z" suffix. 2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record or the Cert ificate of Compliance Annex A. Product flyer for PVI-3.0/3.6/3,8/4.2-TL-01LITD I ABB solar invert —2DD Vtic —3a0 V00 0480 Vdc --�- u Technical data and types Type code HxW PVI-4.2-OUTD-US s,s xo .s.nmwm •m w PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US 7 Jnlppingweight....................................................................................................€..................................................................................... �..t)UID.(.!.:UK91'.................................................. Mounting..system............................................................................................................................... Wall bracket Trade size KOs (tea x 1/2") and Zea x 1-1/4", 3 places side, front Conduit connections2 Side: (2) plugged 3/4" openings, (2) Concentric KOs 3/4", 1" Safety and EMC standard arc All data is subiect to chanoe without notice ers 3 CSA S � Group Certificate of Compliance Certifi cate: 2708406 Project: 2722409 n, WI 53151 USA Master Contract: 259813 Date Issued: April 24, 2014 Issued to: ABB, Inc. 16250 W. Glendale Drive New Berli The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only.icp Issued by: Jocelyn Jens Product Group Coordinator C US Authorized by: Lindsay Clark Operations Manager PRODUCTS CLASS 5311 09 -POWER SUPPLIES -Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES -Distributed Generation -Power Systems Equipment - Certified to U.S. Standards Utility Interactive Invert er, Models PVI-4.2-OUTD-US, PVI-3.8-OUTD-US, PVI-3.6-OUTD-US, PVI-3.0-OUTD-US, PVI-4.2-OUTD-S-US, PVI-3.8-OUTD-S-US, PVI-3.6-OUTD-S-US, PVI-3.0-OUTD-S-US, PVI-4.2-OUTD-S-US-A, PVI-3.8-OUTD-S-US-A, PVI-3.6-OUTD-S-US-A, PVI-3.0-OUTD-S-US-A, PVI-4.2-OUTD-US-W, PVI-3.8-OUTD-US-W, PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W; provided with two DC input channels, permanently connected, system ratings as follows: Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including "—Z" suffix. 2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record or the Cert ificate of Compliance Annex A. Product flyer for PVI-3.0/3.6/3,8/4.2-TL-01LITD I ABB solar invert IRON RIDGE Datasheet Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20 -year warranty. Strength Tested PE Certified All components evaluated for superior Pre -stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s). Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. Address: 1495 Zephyr Ave Address: 1435 Baechtel Road Hayward, CA 94544 Willits, CA 95490 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Phone: (800) 227-9523 Phone: (800) 227-9523 (510) 225-0973 FAX: (707) 459-1833 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Email: jnorsworthy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4007559 Authorized by: for Thomas J. Patterson, Certification Manager ETL CLASSIFIED 0()t3W0us Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any parry, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client Is authorized to permit copying or distribution of this Authorization to Mark and then onty in its entirety. Use of Intertek's Certification mark Is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: N/A Models: 51-61 GD -005, 51-61 GD -0056, 51-5000-001, and 51-65-001 ATM for Report 101541132LAX-002 Page 1 of 3 ATM Issued: 10 -Nov -2014 ED 16.3.15 (11 -Jan -13) Mandatory ®fid IRON RIDGE Simplified Grounding For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. 2 Tech Brief integrated Grounding System Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. Installation Overview Fil Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type • Attach L -Feet to flashing or standoff. ® Prepare Rail Connections • Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. ❑0 Mount & Ground Rails • Attach rails to L -Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. Fe Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. Tech Brief CIL- Module ` - Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60 -cell and 72 -cell solar module frames with box construction and a range of anodization thicknesses. The testing process closely mirrors that �..� Grounding Strap � � � I All solar modules listed to UL 1703 and with frame construction ' of UL 1703, the solar module testing within the parameters stated above are compatible with the . . - I - `-'- ^ Grounding Straps are used to � :,� standard, including temperature and IronRidge Integrated Grounding System. bond rail -to -rail connections. Grounding Lug humiditycycling, electrical and mechanical They are only required on the A single Grounding Lug µ rail with the grounding lug. load testing, and manufacturing quality O Go to ironridge.com/ig connects an entire row of PV modules to the reviews. grounding conductor. IN me 20f3 IronRidge, Inc. All rights reserved. visit www.ironridge.co =11,1:-800122 7573 for more information. ���' 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the sample(5) of the below product Itdve been found to comply with the requirements of the referenced specifications at the time the tests were carried out. licant Name & Address: IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA Puroduct Descn ton• 7cn XR Rails with Integrated Grounding. I Ratings & Principle Characteristics: Models: grand Name: Relevant Standards: Verification Issuing Office: Fire Class Resistance Rating: -Tilt Mount (Asymmetrical). Class A Fire Rated for Low Slope applications with Type1, 2 and 3, 'listed photovoltaic modules. Class A Fire Rated for Steep Slope applications when using Type 1 and 2, listed photovoltaic modules. Angle of tilt allowed by the systems is any greater than or equal to 10 and spedfled ln,the Installatiun imAi uclions. A minimum of a 3" anchor and a minimum of,a 6" tilt -legis required. Naperimetpr guarding is required, 51-61GD-005, 51-61GD-005B, 51-5000-001 and 51-65-001 IronRidge Roof Mount UL 2703 Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mountirig UeVICPS, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing 01_1703 Third Edition'iiated Nov. 18,_ 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Diive ,.. �... Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 1101769343MID-001rl, 101769343MID-001a, 101915978MID-001 & 101999491MID-001arl-crl. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chad Naggs Reviewed by: Gregory Allen Title: Technician II, Fire Resistance Iltle., Enghieeih%,Team Lead, fire Resistance Signature: � Signature: Date: 03/30/2015 Date: 03/30/201 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek 's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification ore relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or hos ever been under on Intertek certification program. GFT -OP -11a (24 -MAR -2014) SN/L IronRidge 1495 Zephyr Ave Hayward, CA 94544 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers 5224 South 39' Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 www.smieng.com Attn: Mr. David r'. Taggart, Vice President Products Subject: IronRidge XR10 Rail, Tilt Leg Mounting System — Structural Analysis Dear Sir: June 16, 2014 Page 1 of 9 We have analyzed the lrnnRirlgP XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures International Building Code, 2012 Edition California Building Code, 2013 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC; -ES Aluminum Design Manual, 2010 Edition Thu tiui►Ridgv XR10 Rail is An extruded aluminum oac.tion with an overall depth of 1 75 in and n net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The Tilt Leg Mounting System allows the solar modules to be supported at an angle to the underlying iuuf structure. Thc systcm consist:a of (2) rowo of stub poste (roof attachments) attanhed to the roof framing. A short extruded aluminum tilt leg is attached to each of the U -buckets on top of the roof attachments along the low side of the module array. A longer tilt leg is attached to each of the U - brackets along the high side. The length of the low side tilt leg is constant and independent of the tilt angle. The length of the high side tilt leg determines the tilt angle. The IronRidge Standard rails span horizontally between the tilt legs. All loads ate transferred to the roof' training thwugh rho tilt legs And roof attachmonto by uirnplu bi axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail or the solar modules not come into contact with the roof. Lateral loads are resisted by the roof attachments and their attachment to the underlying roof framing. The. e?ffent of snismir, loads (for all design categories A -f) have been determined to be less than the effect due to wind loans in all Inari nnnrlitinns and combinations. Therefure, the ntaxilllutir allowable spans for common load cases due to wind and snow are shown in Tables 1 through 4 below. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge June 16, 2014 IronRidge June 16, 2014 Mr. David F. Taggart Page 3 of 9 Mr. David F. Taggart Page 5 of 9 IronRidge XR10 Rail, Tilt Leg Mounting System — Structural Analysis IronRidge XR10 Rail, Tilt Leg Mounting System — Structural Analysis Notes — see page 9 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers Table 1B - MAX. SPANS (inches) - Module Tilt 16 - 25 deg - Wind Zone 1 XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 62 55 46 43 38 33 30 27 24 22 105 59 53 45 42 38 33 30 27 24 22 110 57 52 45 42 37 33 30 27 24 22 120 53 50 43 40 36 33 30 27 24 22 Category B 130 50 48 41 39 35 33 30 27 24 22 140 47 45 40 38 35 32 30 27 24 22 150 44 43 39 37 34 31 29 27 24 22 160 42 42 37 35 33 30 28 26 24 22 170 39 39 36 34 32 30 28 26 24 1 22 100 54 50 43 40 37 33 30 27 24 22 105 52 49 42 40 36 33 30 27 24 22 44 110 50 48 41 39 35 33 30 27 24 22 42 120 46 45 40 37 34 32 29 27 24 22 Category C 130 43 43 38 36 33 31 29 27 24 22 36 140 40 40 36 35 32 30 28 26 24 22 33 150 38 38 35 33 31 29 27 25 24 22 31 160 36 36 34 32 30 28 26 25 23 22 29 170 34 34 32 31 29 27 26 24 23 22 100 50 48 42 39 36 33 30 27 24 22 105 48 46 41 38 35 32 30 27 24 22 110 46 45 40 37 34 32 29 27 24 22 120 43 43 38 36 33 31 29 27 24 22 Category D 130 40 40 36 34 32 30 28 26 24 22 140 37 37 35 33 31 29 27 25 24 22 150 35 35 33 32 30 28 26 25 23 22 160 33 33 32 30 29 27 25 1 24 23 21 170 31 31 30 29 28 26 25 23 22 21 Notes — see page 9 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers Notes — see page 9 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -3- -5- Table 2A - MAX. SPANS (inches) - Module Tilt 16 - 25 deg - Wind Zone 2 XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 54 54 46 43 38 33 30 27 24 22 105 52 52 45 42 38 33 30 27 24 22 110 50 50 45 42 37 33 30 27 24 22 120 45 45 43 40 36 33 30 27 24 22 Category B 130 42 42 41 39 35 33 30 27 24 22 140 39 39 39 38 35 32 30 27 24 22 150 36 36 36 36 34 31 29 27 24 22 160 34 34 34 34 33 30 28 26 24 22 170 32 32 32 32 32 30 28 1 26 24 22 100 46 46 43 40 37 33 30 27 24 22 105 44 44 42 40 36 33 30 27 24 22 110 42 42 41 39 35 33 30 27 24 22 120 39 39 39 37 34 32 29 27 24 22 Category C 130 36 36 36 36 33 31 29 27 24 22 140 33 33 33 33 32 30 28 26 24 22 150 31 31 31 31 31 29 27 25 24 22 160 29 29 29 29 29 28 26 25 23 22 170 27 27 27 27 27 27 26 24 23 22 100 42 42 42 39 36 33 30 27 24 22 105 40 40 40 38 35 32 30 27 24 22 110 39 39 39 37 34 32 29 27 24 22 120 35 35 35 35 33 31 29 27 24 22 Category D 130 33 33 33 33 32 30 28 26 24 22 140 30 30 30 30 30 29 27 25 24 22 150 28 28 28 28 28 28 26 25 23 22 160 26 26 26 26 26 26 25 24 23 21 170 25 25 25 25 25 25 25 23 22 21 Notes — see page 9 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -3- -5- IronRidge June 16, 2014 IronRidge June 16, 2014 Mr. David F. Taggart Page 7 of 9 Mr. David F. Taggart Page 9 of 9 IronRidge XR10 Rail, Tilt Leg Mounting System — Structural Analysis IronRidge XR10 Rail, Tilt Leg Mounting System - Structural Analysis Notes — see page 9 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers Notes — Tabulated values are based on the following criteria: 1. Building mean roof height = 30 ft 2. Risk Category I 3. Module tilt is measured as the angle between the module and 0 degrees (horizontal). 4. For reverse tilt applications module tilt is measured as the angle between the module and the roof slope and is limited to regions with 0 psf snow load requirements. 5. Solar module long dimension = 67.5 in and 40 in short dimension 6. Provide 2 in. min. clear between roof and rail 7. End cantilever span (max) = 0.40 x maximum span from tables above 8. No rail splices in end spans 9. No rail splices in middle 1/3 of interior spans 1.0. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. The rails, including the connections and associated hardware, are to be installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual" by IronRidge and generally accepted standards of construction practice. Additional information, including the requirements for the full range of configurations, is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager 41 4-1`•/ yo C 71973 % ,Ar EXP.I t dr _ C10- Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -7- -9- Table 36 - MAX. SPANS (inches) - Module Tilt 16 - 25 deg - Wind Zone 3 XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 44 44 44 43 38 33 30 27 24 22 105 42 42 42 42 38 33 30 27 24 22 110 40 40 40 40 37 33 30 27 24 22 120 37 37 37 37 36 33 30 27 24 22 Category B 130 34 34 34 34 34 33 30 27 24 22 140 32 32 32 32 32 32 30 27 24 22 150 29 29 29 29 29 29 29 27 24 22 160 27 27 27 27 27 27 27 26 24 22 170 26 26 26 26 26 1 26 26 1 26 24 22 100 37 37 37 37 37 33 30 27 24 22 105 36 36 36 36 36 33 30 27 24 1 22 110 34 34 34 34 34 33 30 27 24 22 120 31 31 31 31 31 31 29 27 24 22 Category C 130 29 29 29 29 29 29 29 27 24 22 140 26 26 26 26 26 26 26 26 24 22 150 25 25 25 25 25 25 25 25 24 22 160 23 23 23 23 23 23 23 23 23 22 170 21 21 21 21 21 21 21 21 21 21 100 34 34 34 34 34 33 30 27 24 22 105 33 33 33 33 33 32 30 27 24 22 110 31 31 31 31 31 31 29 27 24 22 Category D 120 28 28 28 28 28 28 28 27 24 22 130 26 26 26 26 26 26 26 26 24 22 140 24 24 24 24 24 24 24 24 24 22 150 22 22 22 22 22 22 22 22 22 22 160 21 21 21 21 21 21 21 21 21 j 21 170 20 20 20 20 20 20 ZO 20 20 1 20 Notes — see page 9 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers Notes — Tabulated values are based on the following criteria: 1. Building mean roof height = 30 ft 2. Risk Category I 3. Module tilt is measured as the angle between the module and 0 degrees (horizontal). 4. For reverse tilt applications module tilt is measured as the angle between the module and the roof slope and is limited to regions with 0 psf snow load requirements. 5. Solar module long dimension = 67.5 in and 40 in short dimension 6. Provide 2 in. min. clear between roof and rail 7. End cantilever span (max) = 0.40 x maximum span from tables above 8. No rail splices in end spans 9. No rail splices in middle 1/3 of interior spans 1.0. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. The rails, including the connections and associated hardware, are to be installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual" by IronRidge and generally accepted standards of construction practice. Additional information, including the requirements for the full range of configurations, is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager 41 4-1`•/ yo C 71973 % ,Ar EXP.I t dr _ C10- Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -7- -9- 6ZBase Low Slope Mount I QMLSH �---{ 01.25 ABASE (ITEM 2) AND POST (ITEM 4) 1_ AVAILABLE IN 7", 9", AND 12" HEIGHTS. ❑2 AVAILABLE IN MILL, CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. rE: 4/30/2013 ^5 1 WEIGHT: 1.01SHEET I OF I L - -- Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. BI 7.2.3-5 Quick Mount PY" RESPECT THE ROOF .. ..capacities Lag Bolt Specifications sealing washer (item 5), in the interim before racks are in - post after securing the base to the roof. Attach the base/ specific Gravity Wee 5116" shaft per 2.5" thread depth 5/16" shaft per 1" thread depth Douglas Fir, Larch .50 1330 266 Douglas Fir, South .46 1175 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f 8 higher) .46 1175 235 Hem, Fir .43 1060 212 Hem, Fir (North) .46 1175 235 Southern Pine .55 1535 307 Spruce, Pine, Fir .42 1025 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 1330 266 Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. BI 7.2.3-5 Quick Mount PY" RESPECT THE ROOF sure to seal off the post from weather exposure with the Oct -2013, Rev 4 6ZBase Low Slope Mount Instructions Installation Tools Required: Drill with 7/32" bit, impact gun with 1/2" socket, l tube of sealant compatible with roofing materials, pencil, chalk line Locate the desired mount placement over a rafter (or cus- tom wood blocking). Using the base as a template, mark the two penetration points with either a pen or light drill- ing. Use two opposing holes on the base plate, parallel to the structural member. Drill both pilot holes with a 7/32 -inch bit. Make sure to hold the drill square to the rafter. The lag bolts must be an- chored into a structural member, so it is very important to hit the center of the rafter with your pilot holes. Fill the pi- lot holes with a sealant compatible with roofing materials. Prior to attaching the base to the roof, place the grade -8 Attach the hardware (items 5-8) to the top of the post. (Be hex bolt (item 1) in the bottom of the base (item 2) and sure to seal off the post from weather exposure with the screw the post (item 4) in. This is easier than adding the sealing washer (item 5), in the interim before racks are in - post after securing the base to the roof. Attach the base/ stalled.) You are now ready to flash the mount, roof around post assembly to the roof with two lag bolts (item 3). it, and attach racking. Aluminum flashings for built-up BI 7.2.3-5 roofs are available from Quick Mount PV in 4" and 8" cones (sold separately). For membrane roofs, be sure to use man- ufacturer -specified flashing and utilize the services of a certified roofer. (4uick Mount Ft 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com 2700 Mitchell Dr., Bldci 2 • Walnut Creek, CA 94598 Oct -2013, Rev 4 020113 by Quick Mount PV. All rights reserved. �CI14EM LL1iNK** CHEMCURBrMSYSTEM PENETRATION SEALS POcYMER INNOVATION Technical Data Guide Polyether Technology CSI Section No. 07 12 13 CHEM LINK Brands Telephone: 800-826-1681 Fax: 269-679-4448 353 E Lyon Street Schoolcraft, MI 49087 www.chemlink.com Product Description The ChemCurb System replaces the old style metal pitch pans with versatile precast curb components, pourable sealant, and structural adhesive/sealant. The system can usually be installed in under 15 minutes and eliminates the need for flashing or mechanical attachment. The ChemCurb System is designed for use on granulated modified bitumen, PVC, EPDM, PIB, TPO single ply, asphalt, and coal tar B.U.R. Please note TPO Primer must be used on TPO single -ply roof substrates. When installed properly, the ChemCurb System forms a durable waterproof rubber seal around penetrations of any size. An extended manufacture warranty against leaks is activated when CHEM LINK receives a completed warranty card and proof of purchase. Special Characteristics • Rapid installation - reduces labor significantly. • Excellent adhesion to most roofing materials. • No flashing or mechanical attachment required. • Sealant is flexible down to -40°F (-40°C). • Service Temperature -40°F to 200•F (-40°C to 93°C) • 1 -Part® accommodates movement and is suggested for use on all granulated membranes and details with excessive movement. • For sloped roof applications, substitute DuraLink— non-slump adhesive/sealant for M-1® and 1 -Part Restrictions • Please contact customer service for application guidelines with temperatures below 32•F (0°C). • Do not install if rain is anticipated within 4 hours • Do not use on Hypalon or smooth APP modified bitumen membrane. For smooth APP, torch down a target of granulated APP before installation. • TPO Primer must be used for TPO applications. • Do not prime bonding surfaces with asphalt primer • Do not use asphalt cement as a "night sealant." Use M-1 for this purpose. • ChemCurb kits are designed to contain enough 1 -Part to fill each curb with displacement in consideration. Refer to our penetration calculator under contractor resources at chemlink.com to verify volumes Last Revision: 01/16/15 Document No. L1307 ChemCurb System Components • ChemCurb exterior rings, straights, and corners. • M-1 Structural Adhesive/Sealant used for bonding the ChemCurb components, sealing and priming the penetration. • 1 -Part moisture cure pourable sealer or PRO PACKT"' two-part urethane pourable sealer. Both sealants are used to form a durable, water -tight seal around the roof penetration. ChemCurb precast form components are composed of gray polyester resin. The ChemCurb is 2 -inches high and is available in a variety of shapes and sizes. Bisected circular curbs have an inside diameter of 7.5 or 5 inches. Straight pieces are available in 6 and 12 inch lengths and combined with 2 -inch radius corners to create larger sizes. The outer surface is impervious to ice, corrosion, UV (ultraviolet) light, and ponding water. M-1 Structural Adhesive/Sealant is a durable, self - fixturing, moisture cure mastic. Cartridges of M-1 are supplied in each ChemCurb Kit. 1 -Part is a highly flexible, self -leveling moisture cure pourable sealer that eliminates mixing. It is also 100% solid rubber, has a very low VOC content, will not melt or shrink, and is resistant to deterioration. It is supplied in 10.1 -oz and 28 -oz cartridges or 1/2 gallon pouches. Unused sealant can be capped and reused. US Patent No. US 5,768,838 and US RE41,586 � 1 '40fEM.L POLYMER INNOVATION re4lant Technical Data Guide Polyether Technology CSI Section No. 07 92 13 CHEM LINK Brands Telephone: 800-826-1681 Fax: 269-679-4448 353 E Lyon Street Schoolcraft, MI 49087 www.chemlink.com Product Description Dural -ink is an extremely elastic moisture curing sealant designed for use in residential siding, metal architecture, curtain wall construction and joints subject to movement. Dural -ink's adhesion to difficult surfaces permits its use on anodized metal and coatings such as Kynar 500® PVDF. Dural -ink will not stain absorbent stone substrates like limestone or marble. Dural -ink's unique polyether chemistry eliminates out -gassing on green concrete and protects against "sun tanning" or discoloration when exposed to ultraviolet light. Applicable Performance Standards • ASTM C920, Type S, Grade NS, Class 50, Uses NT, TZ, M, G, A& O • Federal Specification TT -S -00230-C Type ll, Class A • Corps of Engineers CRD -C-541, Type II, Class • Canadian Standards Board CAN 19, 13-M82 • SWR Institute Validated (Sealant Waterproofing and Restoration) • AAMA 802.3-08 Type ll, AAMA 803.3-08 Type I, and AAMA 805.2-08 Group C Regulatory Compliance • Conforms to OTC Rule for Sealants • Meets requirements of California Regs: CARB, BAAQMD and SCAQMD • Conforms to California Proposition 65 Conforms to USDA Requirements for Non-food Contact Green Standards: • LEED 2.2 for New Construction and Major Renovations: Low Emitting Materials (Section 4.1) 1 Point • NAHB Model Green Home Building Guidelines: 5 Global Impact Points • VOC Content: less than 19 grams / liter ASTM D2369 EPA Method 24 (tested at 240•F / 115•C) Last Revision: 01/19/15 Document No. L1260 Advantages • Bonds to Kynar 500® PVDF coated metal • Solvent free, 100% solids will not shrink • Non -slump, applies vertically and overhead • 30 minute skin over • No outgassing on damp surfaces • Color stability, will not suntan • Paintable within 24 hours (See limitations) • +/- 50% joint movement Medium Bronze Dark Bronze Black Forest Green �. * Color matching is available in batch quantity only Packaging • 10.1 oz (300 ml) 24 cartridges/carton, 45 cartons/pallet • 20 oz (600 ml) 12 sausages/carton, 40 cartons/pallet • 2 and 5 gallon pails or 50 gallon drums available by special order wQnruL 1311 ASSOCKMEMBER aTT NIPI�ST�TUTE ,4Qfj�g Contractor Hot Line 90-01-20 • • • e001s00s 0 www.chemlink.com MEMBER Lincus Product Datasheet ENERGY The LGate 120 combines a revenue -grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers. DATA COLLECTION AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via available RS -485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms. NETWORK CONNECTIVITY The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or available Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable. FEATURES • ANSI C12.20 power meter • RS -485 and Zigbee inputs • GSM cellular or Ethernet connectivity • Over the air firmware updates • Easy, low cost installation • Doesn't require entrance into the building • Plug and play activation • LCD display DIAGRAM - TYPICAL CONFIGURATION PV ARRAY DIMENSIONS LOCUS ENERGY METER BASE COMM MODULE METER MODULE OS Custom version of Linux 2.6, OTA firmware updates Memory 128 MB RAM Shielded CATS LCD screen Warranty 5 year limited warranty • COMMUNICATION OPTIONS y4 t Model Number LGate120-3Gx ii LGate120-3Gy LGate120-3Gz Cellular - 3G GSM ✓ ✓ ✓ INTERNET ✓ Modbus ✓ Zigbee ✓ Ethernet RJ -4510/100, DHCP/Static ✓ comes n II can Mon ELECTRICAL AMM MMM SERVICE INVERTER(S) LGATE 120 PV ARRAY DIMENSIONS LOCUS ENERGY METER BASE COMM MODULE METER MODULE OS Custom version of Linux 2.6, OTA firmware updates Memory 128 MB RAM Display LCD screen Warranty 5 year limited warranty • SPECIFICATIONS DATALOGGER Processor ARM9 embedded CPU OS Custom version of Linux 2.6, OTA firmware updates Memory 128 MB RAM Display LCD screen SOCKET METER 6.S Accuracy ANSI 12.20 (Class 0.2%) Voltage Inputs 120 - 480 VAC Max. Current Input 200 A Service Type Single phase, 60 Hz Socket Type 2S ANSI 12.20 class 0.2% FCC Part 15B PTCRB AT&T Carrier Compliance 1 Enclosure NEMA 3R Type Weight 8 oz Dimensions 6.95" x 6.5" x 7.3" Environment -20 to 60C, all-weather Warranty 5 year limited warranty COMMUNICATION OPTIONS y4 t Model Number LGate120-3Gx ii LGate120-3Gy LGate120-3Gz Cellular - 3G GSM ✓ ✓ ✓ r RS -485 2 and 4 wire ✓ Modbus ✓ Zigbee ✓ Ethernet RJ -4510/100, DHCP/Static ✓ SOCKET METER 6.S Accuracy ANSI 12.20 (Class 0.2%) Voltage Inputs 120 - 480 VAC Max. Current Input 200 A Service Type Single phase, 60 Hz Socket Type 2S ANSI 12.20 class 0.2% FCC Part 15B PTCRB AT&T Carrier Compliance Single Meter Sockets -Without Bypass 125 & 200 Amp 011 (closed) U204(open) Application • Single meter position • Reccive ANSI C12.10 wattltuur meters • Surface or flush mount (see chart) Gattislruuliun • Ring type • NEMA Type 313 Ut • ANSI 61 gray E -coat finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - 50365 • ANSI C12.7 • 200ATriplex Ground - ETB200 • AW Hub Part/UPC Catalog Amp Overall Dimensions Service Top Knockout Connections Number Number Number Rating Jaws Type Access Line Load Neutral 78205142000 011 125 4 10/3W OH/UG #14-2/0 #14-2/0 #14 - 2/0 78205142040 011 F 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 7620_5142045 _ 011 MS73 125 - 4 10/3W OH/UG #14 ;-2/0 #14 - 2/0 #14 - 2/0 78205142050 011 SF 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205144030 927 100 7 3_0/4W OH/UG #14 -1/0 #4- i/O #14 - 2/0 78205156000 204 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156020 204 F 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350 - tM 78205156030 204 F MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 178M156640 204 MS68 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156035 204 MS68A 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM i 78205108490 204 M_ S7_3 _ 200 4 _ — - OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156005 U204 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 76205156045 U204 F 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156060 U204 F MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156070 U204 MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 --350MCM 78205156140 U207 200 7 30/4W MUG #6 - 250MCM #6 - 250MCM #6 - 250MCM ' 78205156170 U207 F ~� 200 ) A 30/4W UG %/6 250MCM #6 250MCM #6 - 250MCM 78205156180 U207 MS73 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM Part/UPC Catalog (U) 204 Overall Dimensions (U) 207 Top Knockout Number Number Height Width Depth Provision Layout 78205142000 011 12" 8" 45/8" AW Hub Fig. 1 78205142040 011 F 12" 8" 45/8" 2" max KO Fig. 1 78205142045 011 MS73 17" 8" 45/s" AW Hub Fig.1 76205142050 011 SF 12" 81" 45/8" 2" max KO Fig.1 78205144030 927 17" 61" 45/e" AW Hub Fig. 1 78205156000 204 15" 81" 45/e" AW Hub Fig. 2 i 78205156020 204 F 15"" 81" 6" 2" max KO Fig. 2 78205156030 204 F MS73 15" 6" 6" 2" max KO Fig. 2 ' 78205156040 204 MS68 15" 6" 45/8" AW / 2" Hub Fig. 2 78205156035 204 MS68A 15" 81' 45/8" AW / 2" Hub Fig. 2 78205108490 2_04 MS73 15" 8" 45/8" None Fig. 2 78205156005 U204 15" 12" 45/8' None Fig.3 78205156045 U204 F 15" 12" 6" (2) 2" max KO Fig. 3 78205156060 U204 F MS73 15" 12" 6" None Fig. 3 782_0515_6070 U204 MS_73 15" 12" 45/s" None Fig. 3 78205156140 U207 18" 12" 5" AW Hub Fig. 4 AIC Note: 78205156170 U207 F 18" 12" 5" 2'/2" max KO Fig. 4 For short circuit current 78205156180 U207 MS73 18" 121' 5" AW Hub Fig. 4 ratings see page 131. B -Line by 6:T•N Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 5 Meter Mounting Equipment Single Meter Sockets -Without Bypass 011 F - Flush Mount (U) 204 MS68 - 2" Conduit Hub (U) 207 MS68A - MS73 + MS68 927 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel Knockout Layouts Fig. 1 Top Provision /.-1 O 4F 4F both sides p 1A Fig. 3 -.-...,.-.:-4Tbp Provision 4F 01 4G 4F des e O 4G 1W 125 & 200 Amp 1W=1/a' 1 A = 1/2' 2A = 1/2' - 1/4' 4F=2"-11/2'-11/4'-1' 4G = 21/2' - 2" - 11/2' - 11/4' Top Provision = See Chart Fig. 2 Top Provision 4F both sides 4F 1A Fig. 4 Top Provision 0 4G 14 4G 4G botch sides 4G 2A Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment B -Line by E:T=1N - October 22"d, 2013 This letter is to certify that the LGate 120 and LGate 320 are communication boards built into the Vision Meter 2S CL200 and 16S CL320 socket meters, respectively. Each of these meters was certified to the ANSI C12.20 (class 0.2%) standard by Underwriters Laboratory on June 7, 2013 as part of the Vision Meter Family (Project Number 12CA71134, Job Number 1001541515, and Report Number R12CA71134- ANSI). ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications. These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety, as well as resistance to various types of mechanical shock. As electrical socket meters are generally installed and maintained by trained and. certified professionals, rather than consumers, they do not fit the typical criteria for additional types of UL or IEC certification. If you have any further questions regarding the product certification of any Locus Energy LGate-branded device, please contact us at support@locusenergy.com. The Locus Energy Team Locus Energy, LLC www.locusenergy.com