Loading...
BMCH2016-007378-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BMCH2O16-0073 Property Address: 54075 SOUTHERN HILLS APN: 775101061 Application Description: TERRRY CENNON Property Zoning: Application Valuation: $49,570.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 c&tv,440alftro COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT A '�pMAR 0 D CITY OF LA QUINTA Y DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20. C36 License No.: 686310 Date: 3 3C) I Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business.and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. _ . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under.penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's i 111111 11111 1111 1111 _ 78 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/30/2016 Owner: PGA WEST RESIDENTIAL HOMEOWN P 0 BOX 1060 LA QUINTA, CA 0 Contractor: HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS, CA 92276 (760)343-7488 Llc. No.: 686310 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. —�� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 3I��Ilb Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,.the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,. and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. c-� Date:3 13011 Signature (Applicant or Agent): FINANCIAL •• • DESCRIPTION ACCOUNT QTY AMOUNT' PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 •$0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00 DESCRIPTION ACCOUNT QTY, AMOUNT PAID PAID DATE HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $217.56 $.0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $108.78 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for CHANGEOUT:. $326.34 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID -PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0:00 TOTALS:• 0• Description: TERRRY CENNON Type: MECHANICAL Subtype: Status: APPROVED Applied: 3/30/2016 RSE Approved: 3/30/2016 RSE Parcel No: 775101061 Site Address: 54075 SOUTHERN HILLS LA QUINTA,CA 92253 Subdivision: TR 22432-2 SEE ASSESSORS MB 769/43 Block: Lot: 6 Issued: FOR CMS Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $49,570.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 ADDRESSI Details:' HVAC CHANGE OUT - 19.OSEER/80AFUE SPLIT SYSTEM HVAC CHANGE OUT - 2-21.OSEER/80AFUE SPLIT SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL SITES CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT IE INC 31225 LA BAYA WESTLAKE VILLAGE CA 91362 CONTRACTOR HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS CA 92276 FRANCISCO@CALLTHE GENERAL.COM OWNER PGA WEST RESIDENTIAL HOMEOWN P O BOX 1060 LA QUINTA CA 0 Printed: Wednesday,. March 30, 2016 11:10:31 AM 1 of 2 C IVEY SYSTEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA: HVAC CHANGEOUT - 101-0000-42402 0 $217.56 $0.00 SPLIT -SYSTEM HVAC CHANGEOUT - 101-0000-42600 0 $108.78 $0.00 SPLIT -SYSTEM PC Total Paid for CHANGEOUT:. $326.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:1 1 1/ INSPECTIONS PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE Printed: Wednesday, March 30, 2016 11:10:31 AM 2 of 2 &ff[T SYSTCMS Bin. # CJty, Of La Quin to 81MO,- 8t Safety Division P.O: Box 1504,78-495 Calle Tampico 1.a.Quinta, CA 92253 -:(760) 777-7012 - 0 73 Building Permit Application and Tracking Sheet Permit # y►� Cj" Project Address: 54075 Southern Hill Owner'sName:.Terry Cennon A. P. Number. Address: 54075 Southern Hill Legal Description: City, ST, Zip. La Quints, CA :92253 Contractor. General Air Conditioning Telephone: 760-898-8700 �:'' �3;? •';3. "" s.w Address: 31170 Reserve Drive Project. Description: Replace (1) Ston Complete HVAC System. . City, ST, Zip: Thousand Palms, CA 92276. Replace (1) 4ton Complete HVAC System, Telephone: 760-343-7488 K. ;: ;.,w :. '� Replace (1) 2ton Complete HVAC System State Lic. # : 686310 City Lir 9. Arch., Engr., Designer. Address: City., ST. Zip: Telephone: �� State Lie,#:j c Name of Contact Person: Steven Schnierer Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq.Ft.: —T# Stories- #Units: Telephone # of Contact Person: 818-73577876 Estimated Valae of project: $49,570.00 . APPLICANT: DO NOT WRITE BELOW THIS UNE N. Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact Person Plan Check Balance. Title 24 Cates. Plans pieked.up Construction Flood plain plan Plans resubmitted Mechanical G:mding plan 2" Review, ready for correctionslissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correetionsRssue ' Developer Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE.OF COMPLIANCE CF111-ALT 024E ` Alterations to Space Conditioning Systems (formerly CF -SR -ALT -HVAC) (Page 1 of 3) Project Name: TERRY CENNON I Date Prepared: 2016-03-29 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one MR -ALT -02 document for each dwelling unit. 03 Project'Name TERRY CENNON 02 Date Prepared 2016-03-29 03 Project Location 54075 SOUTHERN HILL 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name. TERRY CENNON 07 Zip Code 92253 08 Dwelling Unit Conditioned 2300 � `'-,'�,'' �� �' `" -�"'" �r °� '� k` Floor Area (ft2) SC -System SC System CFA served ystem a re rfrf igera t 4 Number of space conditioning �il stallAg I 09 Climate Zone 15 10 (SC) systems in this dwelling 3 ducted containing R system v more than 40 unit. entirely new B. Space Conditioning (SC) System Information al fi ;o .fi 01 02 03 05 661 � 07 ) Q8 09 10 .04 jerl 3lls the SCS' ' �ihstall(ng a` � `'-,'�,'' �� �' `" -�"'" �r °� '� k` SC -System SC System CFA served ystem a re rfrf igera t 4 Z]nstaIIIg, ew SC �il stallAg I ]n tailing Installing Identification or Location or Area by this SC ducted containing R system v more than 40 ent ely w entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 900 Yes Yes Yes No No No Altered space conditioning system' System 2 Location 2 900 Yes . Yes Yes 'No. No No Altered space conditioning system System 3 Location 3 900 Yes Yes Yes. -7 No . No I. No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. Registration Number: 216-A0118304A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Regiftration Date/Time: 2016-03-29 21:08:46 Report Version: 2013 Rev 1.007 Schema Version: 0.555SDD HE Provider: CaICERTS Report Generated: 2016-03-29 21:08:39 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150Z(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New. or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new Less than or System 1 furnace heating AFUE 0.8 AC cooling SEER 19 Setback equal to 40 R-8 components components feet Central gas All new Central split All new Less than or System 2 furnace heating AFUE 0.8 AC cooling SEER 21 Setback equal to 40 R-8 components components feet Central gas All new Central split All new Less than or System 3 furnace . heating AFUE 0.8 AC cooling SEER 21 Setback equal to.40 R-8 components components feet Reauired ocumentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums`. R6.IN -, CF2R-MCH 20 H & CF3R-MCH-20-H —Duct Leakage.testing requlred wt�hen heating or cooling'cornp a is are Inst I ed1n Butte stems, or when ore than'40 ff o len replaced. -Leakagesate compliance: 515%, or!' 10% leakage to obtside� al -all accessib leaks bl CF2R-MCH 25-H & CF3R-MCH 25-H Refrigerant Charge Verification:rAlred when refrigerant containing components are Installed or altered (a.011. in CZ 2, 8 15). CF2RCF3R•MCH-23 & CF3R-MCH-23 Air Flow_ 300 CFM/ton require -Men' MCH -A is equ reed. Exceotioni: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECI1-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Section's 150.2(b)1Diia and 1501(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)l -C) This section does not apply to this project. Registration Number: 216-A0118304A-000000000-0000 Registration Date/Time: 2016-03-29 21:08:46 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-03-29 21:08:39 Schema Version; 0.555SDD CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT-HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Jacoby, Documentation Author Signature: Jan dacorr. Ian Company: Signature Date: i PERMIT E RATERS 2016-03-29 21:08:46" Address:" CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive #213 City/State/Zip: Phone: West Lake Village -CA 91362 818-735-7876 Responsible Person's Declaration statement: I certify the following under penalty of perjury, under the• laws of the State of California: 1. The information provided on this Certificate'of Compliance is true and correct. 2. 1 am eligible under Division 3 oft I he Business and Professions Code to.accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That.the energy features and performance specifications, materials; components, and manufactured devices for the building designorsystem design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and. Part 6 of the California Code of �Rlatlons 4. The building design features or system design.features identified orl"thls Certi "cf al�te bf C m liance are onsisten iith< he inform#on.provided on:'oth OP licable compliance documents, worksheets, calculations, plans and specifications submitted to the a forcemen�gency fora' po v 1,vvA�this builditng perr' t ap�plicatI M. 5. 1 will ensure that a registered copy of this Certific to"df, pliance Alhbe"hi er allable with th0 bUllding;pe"fmit(s;issuON etl forf4he;b�Uild g, and ad ay. bl�e to ttie ehforcement agency for all applicable inspections. I understand that a registered copy of thi e ficate of Compliance,,Is required to be,Jncluded with the,,documentation1he�builder p ov des to the building owner at occupancy. Responsible Designer Name: . " Responilhle Desi jii.r Sihnaftre: V 1; �n/ � cJY n �acobJr. Jacoby, Ian Company:. Date Signed: HARRISON ENTERPRISES INC dba GENERAL AIR CONDITIONING 2016-03-29 21:08:46 Address: License: 31-170"RESERVE DRIVE STE A 686310 City/State/Zip: Phone: . THOUSAND PALMS CA 92276 760-343-7488 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0118304A-000000000-0000 Registration bate/Time: 2016-03-29 21:08:46 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-03-29 21:08:39 Schema Version: 0.5555DD