BWFE2016-004578-495 CALLE TAMPICO C0 D
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BWFE2016-0045 Owner:
Property Address: 55080 SUMMER LYNN CT MONTERRA PROP
APN: 767860030 55075 MONROE ST
Application Description: MONTERRA / 32742 / BLOCK WALL LA QUINTA, CA 0
Property Zoning:
Application Valuation: $4,147.25
Applicant:
WOODBRIDGE PACIFIC GROUP LLC
27271 LAS RAMBLAS SUITE #1100
MISSION VIEJO, CA 92691
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 963887
Date:'021' 16 Contractor:( j&zt/21zf,"
OWNER -BUILDER DECLARAT
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or Improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( ) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's N
Lender's Address:
43
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date:
c^
C=1 N
Contractor: I
WOODBRIDGE PACIFIC 'RQU LLC
27271 LAS RAMBLAS S JTE #100
MISSION VIEJO, CA 92691
(949)348-8162
Llc. No.: 963887
2/25/2016
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of Nork for which this permit is issued.
ve and will maintain workers' compensation insurance, as required by
Seof the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE WORKERS' COM PENSATIO OVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE'COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and.for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: ai Signature (Applicant or Agent)
DESCRIPTION
FINANCIAL ••
ACCOUNT,
1•
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
$0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID,
PAID DATE
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$60.91
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid
for FENCE OR FREESTANDING
TOTALS:0•
WALL:
$108.77
$0.00
• ••
Bin # City of La Quinta
Building a Safety Division
Permit # P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
-010pt N h,1 o Building Permit Application and Tracking Sheet
Projctx Address:
�.
O J 641J 17/
�Vo
A. P. Number:
Address:
Legal Description: Ti� . %r';�
! er
City. ST, Zip: i�r/fir t;� y��JG C cls
Contractor: 14�, 1"t 5r �/C-
Telephone:
::< > :;
Address:
Project Description: , `'1 iii% -ivl vZ
City, ST, Zip:
Q 1
Telephone:
<>•.f. �.n:.: A?y5tiar1,�. t:d':�4' •�. i'4�=.•v'%'.�f
:v�,:�:a=�;::>;.,N�,{�:<::E<:>.::.<:-><•:
State Lie. 4:
City Lie. #;
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:
s ts.
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
State Lie. #:
Name of Contact Person:
Sq. Ft:
# Stories:
# Urow.
Telephone #,of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
fl
Submittal
Rea'd
Recd
TRACICIPIG
PERMrr FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
Title 24 Cates,
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°' Review, ready for correctionsrssue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
. Plans picked up
S.M.I.
H.O.A. Approval
Pians resubmitted
Grading
1N HOUSE:-
3a Reylerv, ready for corrections/issue
Developer Impact Fee
Planninr,Approval
- -
-Called, Contact Person_--
-
_
-A.LP.P.. _
Pub. Wks. Appr
Date of permit issue
Schodl Fees
Total Permit Fees
I
6F C6'-0" TO.6'-8 5 PROTO II - EXPOSURE C - .DIP FOOTING
DESIGN CRITERIA (PER 2013 CBC):
1. ALLOWABLE SOIL BEARING PRESSURE PROTO II FENCE WALL
= 1000 PSF MIN.
2. ALLOWABLE SOIL PASSIVE PRESSURE
= 150 PCF MIN.
3. SEE SHEET B, C. & D PRIOR TO 6" STD. HOOK '
START OF CONSTRUCTION.
„ 6" „ CAP BLOCK PER
SHEET C
STEEL PLATE TO BEAR
FULLY ON CENTER WEB
s OR END FACE SHELL -
Il I SIZE PER SHEET C.
Lu
CD
w
U
N
EY
w
Q-
X X
a
■■
a_
CV
Li J
w 0 o
z NCL.w
Lil O2 N
CL
0 o a a
Ln .0
Q W N
0
NO COLD JOINTS--
PERMITTED
OINTS PERMITTED BETWEEN DIP -
AND SETTING PAD
I
HORIZONTAL JOINT N .
REINFORCING TOP 2
COURSES BELOW PLATE
AND AT 24" O.C. BELOW VERTICAL FOOTING
POST TENSION (PT) REINFORCING AT 6'-8" /
ROD SEE SHEET'B FOR FENCE, USE T y4 IN V
ROD SPECS - CENTER CENTER OF DIP 16" MIN
IN WALL
-PROTO II FENCE WALL
r
FOR SIDEYARD RETURN WALLS
WHERE DRAINAGE SWALE
TBACK OCCURS, INSTALL DRAINAGE
PER BLOCK AT SWALE AT GRADE.
NED.- /--FINISHED GRADE
CONTINUOUS
AT HOOK
. z
2 1
MAX
CONT. CONCRETE
SETTING PAD -
SEE SHEET D
lim
POST TENSION (PT)
ROD SEE SHEET B
CONCRETE DIP FOOTING
DIP MAY BE OVER
EXCAVATED AS SHOWN -
FILL WITH COMPACTED
FILL OR CONCRETE
DIP DEPTH AT TOP OF
2:1 SLOPE
SETBACK - FACE OF FOOTING
TO TOP OF SLOPE
MIN. DEPTH Tr -
DIP FOOTING
12" TO 36"
2'-4"
6" TO 11"
2`-11°'
3" TO 5"
31�1"
FENCE WALL SCHEDULE AT LEVEL SOIL
DESIGN WIND PT ROD DIP
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED 1111TH WRITTEN SIGNATURE.
MAX
EXP/4N—•-•SP,AGING-:
SP•AeN•
NUMBER
NTA
1 V TA
SEALED ON
C A T 1' V
I 6'
5'-o TO
6'-0"
DEPT.
d lq �¢
/ /
C AT 1 0 BUILDIW-3
& SAFETY
C AT 1,20
r.=ko
OAYLI,W MIN.
S 40 5 m,
� LINE OF DIP
FOOTING BEYOND,
6'-8"
C AT 1 0
C AT 1.0
- `''' 0"
-- -
�ROTO II
LA O.UIN.
STANDARD
, CA
C AT 1 0
1.,
>th. rmf
DATE
08.19.2014
ENCR
JAC
Sr..,(www.ctsozxom
TURLEYWWW.PROT02.COM
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED 1111TH WRITTEN SIGNATURE.
NUMBER
�� G�• �y.ti.
SEALED ON
14-115-9155
�%
d lq �¢
/ /
no scale
TRACKING jj
DRAWN'
S 40 5 m,
14-115-8964
TMH
w
C(
CARUSO
a=��,�=
PROTO-II T4 WALL SYSTEMS
DATE
08.19.2014
ENCR
JAC
Sr..,(www.ctsozxom
TURLEYWWW.PROT02.COM
pwopp
41800 CASCADES COURT TEMECULA, CA 92591pACKaGE
SHEET
(/CjV��Q.:. tSCOTT
�^ —gg ATTN: GARY OTTOINC.
PH# (951) 694-3793 - garyoltoUproloii:comF
CA��F
s
a
ovaaaa
luny ONLY BE INSTALLED BY APPPOvEO AND CERaTlEO INSIALLERi)
S1.2
»»»
4'. 6'.. AND a' THICK POST-TENSIONEO MASONRY WALLS
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED 1111TH WRITTEN SIGNATURE.
GENERAL STRUCTURAL NOTES
1. SOIL SHALL BE FIRM AND COMPACTED PRIOR TO PLACEMENT OF CONCRETE. PRIOR TO FOUNDATION EXCAVATION, USER SHALL
VERIFY THAT SITE SOILS CONDITIONS MEET OR EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 150 PSF/FT (SOIL
CLASS 4 OR BETTER AS DEFINED BY THE CBC) STARTING AT THE TOP OF GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR
PASSIVE) AND A MINIMUM ALLOWABLE BEARING PRESSURE OF 1000 PSF,
2. FOOTINGS TO BE LEVEL. IF GROUND SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP SHOULD BE PROPER HEIGHT TO FIT
BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND CONTAIN NO LOOSE EARTH OR FOREIGN MATTER.
3. SEE SHEET A FOR EXPOSURE, WIND SPEED, POST TENSIONED ROD SPACING, FOOTING SIZES, ETC. USER IS RESPONSIBLE TO
VERIFY REQUIREMENTS WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE
APPROVED SITE PLAN AND APPLICABLE CODE OR JURISDICTION REQUIREMENTS.
4. SOIL BELOW FOUNDATIONS SHALL BE WELL DRAINED AND NON -EXPANSIVE. USE CONCRETE WITH A MIN. STRENGTH OF 2,500 PSI
- TYPE II CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN. OF
48 HOURS OLD PRIOR TO FINAL TENSIONING ALL. ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS
DURING PLACEMENT.
5. LAP REINFORCING STEEL: LAP = 32" FOR #4 BARS IN CONCRETE.
6. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F -M DESIGN CRITERIA FOR BLOCK IS
BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR TO ROD TENSIONING. STANDARD HEAD AND BED JOINT
BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED, BLOCKS SHALL BE LAID IN RUNNING BOND,
7. MORTAR SHALL BE TYPE S, 2000 PSI MIN. MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL TENSIONING AND 24
HOURS OLD PRIOR TO FINAL TENSIONING.
8. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING.
9. REINFORCING REBAR SHALL CONFORM TO ASTM A641; Fy = 60,000 PSI.
10. PROTO-II HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL THREADS, DIRECT TENSION
INDICATORS (A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE
SHALL BE SUPPLIED BY ONLY AN APPROVED PROTO-II LICENSEE TO THE CERTIFIED INSTALLER. POST TENSION RODS SHALL BE
7/16" DIAMETER WITH 1/2" ROLL THREADS CONFORMING TO ASTM A641 (FY = 60000 PSI) AND HAVE STEEL CHEMISTRY SO
THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION
ROD = .1503 SQUARE INCHES. BEARING PLATES ARE 1/4" THICK (Fy=50 KSI) SEE SHEET C FOR DIMENSIONS. 1/2" COUPLERS
PER ASTM A563 GRADE A, AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED IS DEFINED
AS 1/2" MIN. INTO COUPLER. 1/2" NUTS ARE TO BE GRADE 8, PER ASTM A325. 1/2" ALL THREADS PER ASTM A307, GRADE
60. DIRECT TENSION INDICATOR (DTI - COMPRESSIBLE WASHER) IS MANUFACTURED PER ASTM F959. PLASTIC REBAR SADDLES
ARE NON-STRUCTURAL.
11. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER SHEET A AND CONFORM TO ASTM A82
LADDER TYPE, 9 GAGE DIAMETER. LAP JOINT REINFORCING ONE FULL CROSS SQUARE (6" MINIMUM LAP).
12. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2" COUPLERS AND STRAIGHT RODS THREADED BOTH
ENDS FOR ADDITIONAL LIFTS. RODS SHALL HAVE A MIN. OF 3" 'L' HOOK, WITH 1/2" NUT AT END OF TENSION ROD WHERE
EMBEDDED IN FOOTING.
13. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND 20' ON CENTER IN STUCCOED
WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. POST TENSION ROD SHALL OCCUR WITHIN 12" OF END OF WALL AND
12" EACH SIDE OF CONTROL JOINT.
14. NO COUPLERS MAY OCCUR DIRECTLY BELOW AND IN CONTACT WITH THE BEARING PLATE. NO BOND BEAM BLOCK MAY BE USED
AT PLATE/TENSION LOCATION.
15. TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OPTION; AT CONTRACTOR OPTION,
VERTICAL REBAR MAY BE STABBED DOWN INTO THE DIP.
16. A PROTO-11 DTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN THE BEARING PLATE AND NUT
WITH THE DTI "TABS" FACING UP AGAINST THE BOTTOM OF THE NUT, THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF
FINAL TENSIONING BY A DEPUTY INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS; METHOD
1; VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTI), TABS FACING UP AND COLLAPSED AGAINST NUT WITH NO LIGHT
LEAKAGE BETWEEN THE PROTO-II DTI AND BOTTOM OF NUT. METHOD 2: USE OF A CALIBRATED TORQUE WRENCH TORQUED TO
55 FT -LBS. (DTI MUST STILL BE PLACED WITH METHOD 2. NO VISUAL INSPECTION OF DTI REQUIRED WHEN USING METHOD 2).
INSPECTOR SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND INTEGRITY OF MORTAR
JOINTS, AND PROVIDE A SIGNED REPORT TO ALL REQUIRED PARTIES. PROTO II MASONRY DESIGN IS BASED ON THIS SPECIAL
INSPECTION.
17. POST TENSION ROD SPACING IS INDEPENDENT OF DIP SPACING. TOLERANCE FOR DIP SPACING IS ±12" BUT THE NUMBER OF
FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL, POST TM,LON-R00--,TT-OL-ER*Nee- S t8" BUT
THE NUMBER OF RODS FOR A GIVEN LENGTH OF WALL MUST REMAI 1 1HIi E� QUINTA
18. SEISMIC DESIGN CRITERIA: Ss=2.0, Si=0.749 SOIL CLASS=D (ASSUMED)`` RISK! Afi{EGtiRY I.
19. FOUNDATION INSPECTION PRIOR TO PLACEMENT OF CONCRETE INCLUDE f[QO.. _0VffL t�O�WiO�I- A DF TSA SIZE/DEPTH
AND CLEANLINESS OF FO NOATION. ADDITIONAL SPECIAL INSPECTION A REQUIRAVBYJ''P11LY
En
FOR SlRl
C 1 4n TANDARD
A CAn PQU
F S$ C r
Q
K
'n
DATE _I
JOB MBER
SEALED ON
— —9155
v� Z
811 14
t10 C0�6
TRACKING a
DRAWN
S 40 5
14-115-8964
TMH
Lu m
CARUSO
P
k -HRR
PROTO-II TW WALL SYSTEMS
WWW.PROT02.COM
DATE
08,19.2014
ENCR
* STRU/ T��P� �*
C
("�
SCOTTY
_
_
@�0�1
41800 CASCAOES COURT TEMECULA. CA 92591
ATTN: GARY OTTO
PACKAGE
,IAC
SHEET
ATF
OF CA 1 \`
INC.
.. ,,
5
iE
������
PHg (951) 694-3793 - goryotloCprofoii,com
(WAY ONLY BE INVAELED BY APPROVED AND CERRi1E0 INSTALLERS)
� L`
S1.2
WWW.ctsoz.com
n �v n
1% 6'. AND B' MICR POSE-fuswo WASONRY wALIS
•I')
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION
OR RECORDING
UNLESS THE STRUCTURAL ENGINEER OF RECORDS SEAL
IS AFFIXED1�TH WRITTEN SIGNATURE.
TOP OF PROTO II WALL
KEY NOTES:
/
1.
2.
POST TENSION ROD.
NUT.
\
3.
DIRECT TENSION INDICATOR (DTI).
4.
BEARING TOP PLATE.
5.
COLLAPSIBLE TABS.
6.
MINIMUM TENSION TO BE 6,000 LBS LOAD AND
CONFIRMED BY ONE OF TWO METHODS PER
NOTES "B" & "C" BELOW.
7,
FILL CAP BLOCK WITH MORTAR. IMMEDIATELY
\ /
"FLIP" ONTO ROD. COMPLETELY COVER NUT, ROD
AND PLATE WITH MORTAR.
8.
CAP BLOCK OF SUFFICIENT SIZE TO COVER
PROTO-II
PLATE AND ROD.
9.
CONTINUOUS HORIZONTAL JOINT REINFORCING.
10.
CENTER WEB OR END FACE SHELL BELOW.
(3) PLAN VIEW
11.
STEEL PLATE SIZES:
4) �)
A. 4" PROTO II:1/4"xYx6"
B. 4" SLUMP PROTO 11:1 /4"x2 1/2%6"
�2)
C. 6" PROTO 11:1/4•'x4 1/2°x6°
D. 6" SLUMP PROTO 11:1/4"x4"x6"
STEEL PLATES TO BE PLACED AT THE EDGE OF
THE CELL SO THAT THE PLATE BEARS FULLY ON
THREE SIDES.
12.
00 NOT USE BOND BEAM BLOCK AT BEARING
PLATE LOCATIONS.
J
. sEcnoN
(8)
(7)
NOTES:
A. PROTO II DTI TO BE USED AT EACH TENSION ROD.
TABS FOR DTI SHOULD FACE UP AGAINST BOTTOM
OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES
BETWEEN BOTTOM OF NUT AND DTI) WHEN PROPER
TORQUE OF NUT HAS BEEN ACHIEVED.
B. AS ALTERNATE TO VISUAL INSPECTION OF TABS,
INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY
USE OF A CALIBRATED TORQUE WRENCH. TORQUE
NUTS TO 55 FT -LBS. DTI STILL MUST BE PLACED ON
ROD IF USING TORQUE WRENCH METHOD. SEE
GENERAL NOTE ON SHEET B.
C. SPECIAL DEPUTY INSPECTOR WILL PERFORM A
VISUAL INSPECTION WHEN USING THE DTI METHOD TO
CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT
LEAKS BETWEEN THE TABS AND BOTTOM OF NUT.
IF USING TORQUE WRENCH METHOD, DEPUTY
INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55
FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED.
D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION
OF TENSIONING PERFORMED BY ONE OF THE TWO
METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR
TO PROVIDE A COMPLEIED-REP-ORS-T0-tME0--1
TIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE.
r
FOOTING ELEVATION AT POST TENSION ROD
PROTO II FENCE WALL
Y
! THICKENED FOOTING TO PROVIDE:
3" MIN. COVER AS REQUIRED
AROUND ANCHOR BOLT AND NUT
ELEVATION
7/16" DIA. POST TENSION R
(PT) SEE SHEET B CENTEI
W
THICKENED FOOTING TO PRO'
3" MIN. COVER AS REOUI
AROUND ANCHOR BOLT AND I
CONCRETE SETTING PAD
7/16" DIA. POST. TENSION RODS
(PT) SEE SHEET B CENTER IN
WALL
Y
SECTION
CITY QF LA QUINTA
BUILDING & SAFETY DEPT.
AOl 1'.. ' :.I STAN .:RQ
FOR ICT"S R '�'-p {`SAI CA
I E
RIP! / N
�
PTK1.. �:....
2
, SEALED ON
D/tTE f(q JOB NUMB Ef
-(F, -
rR 5,
CIO)
S.405 m
Of 9 14
TRACKING # DRAWN
n.o: s`c = . 14-115-8964 TMH
Lu
RLEY
P
PROTO•11 TY WALL SYSTEMS DATE ENCR
WWW.PROT02.com 08.192014 JAC
LSTRU. 7U�P�.
C.
T
SCOTT
C
41800 CASCADES COURT TEMECULA, CA 92591
ATTN: GARY OTTO PACKAGE SHEET
�F CALF
INC.
b$'
PH# (951) 694-3793 - goryolloOproloii,com S�
(MAY ONLY BE INSTALLEO BY APPROVED AND CERTRTEO WSTALLERS)J D
www,ctsoz.com
if n
•I�
4'. 6'. AND B• THION POSt-TENSONEO MASONRY WALLS
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION
OR RECORDING
UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED Ma WRITTEN SIGNATURE.
O° /
l i i t l
1 1; LOT 30
PLAN 1
I 55-080 SUMMERLYNN COURT i 1 1
'T• 11
Ir
I
• � is 1 � ..�..1 .�:
-1-1 Y OF LA Ql.Jli`'+%. t
I 1
BUILDING & SAFETY DE �.,
FOR CONSTRUCTION.'
ATE BY
1.:::-.
SUMMERLYNN
�® L COURT
LEGEND NOTE: SOME ITEMS MAY NOT BE APPLICABLE FOR THE LOT SHOWN HEREON.
® ELECTRIC—MANHOLE FENCE —-- AREA DRAIN & DRAIN LINE
0 ELECTRIC—TRANSFORMER T—r-- BLOCK WALL -- = SWALES
® ELECTRIC—PULLBOX RETAINING WALL IN BUBBLER BOX
® TELEPHONE—PEDESTAL 0 PILASTER CURB & GUTTER
' POWER, TELCO, CAN & GAS O FLATWORK CATCH BASIN
METER LOCATION PROPERTY LINE STREET/STOP SIGN
00 AIR CONDITIONING UNITS ---- RIGHT—OF—WAY O H.O.A. MAINTAINED LANDSCAPE
— PUBLIC UTILITY EASEMENT --- STREET CENTERLINE pg POOL EQUIPMENT
-&—S— SEWER MAIN & MANHOLE —W— WATER MAIN
r---- SEWER CONNECTION 0— WATER SERVICE METER POOL/SPA
SLOPE K> FIRE HYDRANT
Wpg 27271 Las Ramblas
Suite 100 MONTERRA LOT EXHIBIT LOT 30
Mission Viejo %� TRACT 32742
WOODBRIDGE California 92691 � PGA A WEST 55-080 SUMMERLYNN COURT
PACIFIC GROUP Tel: 949-348-8162 LA QUINTA, CALIFORNIA
WOODBRIDGE PACIFIC GROUP RESERVES THE RIGHT TO MAKE MODIFICATIONS AND CHANGES TO ITEMS INCLUDING BUT NOT LIMITED TO LOT GRADING AND
DRAINAGE, LOT LINES, FENCE LOCATIONS, PAD ELEVATIONS, TOP AND TOES OF SLOPES, RETAINING WALLS, UTILITIES LOCATION, MAILBOXES, DRIVEWAYS,
SIDEWALKS AND SETBACKS. ALL UTILITIES, SIGNS, FENCES AND DIMENSIONS ARE SHOWN AS APPROXIMATE. LOCATIONS AND DIMENSIONS MAY VARY
DEPENDING UPON CONSTRUCTION CONDITIONS. THIS LOT EXHIBIT WILL NOT BE UPDATED TO REFLECT ANY MODIFICATION, CHANGES OR REVISIONS THAT
HAVE BEEN MADE AS A PART OF THE CONSTRUCTION OF THIS LOT. BUYER IS EXPRESSLY ADVISED NOT TO ALTER THE DRAINAGE OF THE LOT.
OF
Description: MONTERRA / 32742 / BLOCK WALL
Type: WALL/FENCE Subtype: CITY STANDARD/PRE- Status: UNDER REVIEW
Applied: 2/23/2016 SKH
APPROVED
Approved:
Parcel No: 767860030 Site Address: 55080 SUMMER LYNN CT LA QUINTA,CA 92253
Subdivision: TR 32742 Block: Lot: 30
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $4,147.25 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 70LF OF 6' GARDEN WALL AT EAST PROPERTY LINE [PROTO 11 SPECIFICATIONS] PRECISION_ CONCRETE BLOCK SHALL BE COVERED
WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE.
jaMryj
ADDITIONALtSITE
S'._,
s... r. ei S+ >.3 '.� Y'"'��''�r�'^�a '..-,��.`',t''ci`_'ir' . � �f.. i?6 w'i 1'� F 'Ln�J' r � cJlif��.�"^'` •a^+.� Mj .•.`� v. ,, t R^'..:'{t°+m:.:. .xk''.9k:�`a, >..v �.;•�, .,M..».'.. IgE^*
x'' ° +,h z`` .• : ,CHROIVOLOGY4ik
�,, �•: r
:T �;y,,:
'CONDITIONS�}���^�'�_
x
t
Printed: Thursday, February 25, 2016 3:45:45 PM 1 of 2
!J LJ LJ LJ SYSTEMS
Printed: Thursday, February 25, 2016 3:45:45 PM 2 of 2
• A?WYS iEMS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
BSAS 561473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00
BSA:
WALL/FENCE - FIRST
101-0000-42404
0
$47.86
$0.00
100 LF
WALL/FENCE - FIRST
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for FENCE OR FREESTANDING WALL: $108.77 $0.00
TOTALS:•• • •0
Printed: Thursday, February 25, 2016 3:45:45 PM 2 of 2
• A?WYS iEMS