Loading...
BSOL2015-0173a � U �c 0 78-495 CALLE TAMPICO 4o2 204 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENTCOMAfl, 17Yo INSPI - BUILDING PERMIT YOfVF�Op &rosp 67 Application Number: BSOL2015-017.3 ; 1111111 IIIII IIII Illli� Owner: Property Address:44030 SWEETBUSH LN LN 09 LORA BAILIN APN: 604081032 44030 SWEETBUSH LN Application Description: BAILIN/14.575 kW PV SYSTEM- (55)265W PANELS/(2) INV+125A SUB LA QUINTA, CA 92253 Property Zoning: Application Valuation: $32,211.00 Applicant: Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)96.3-4722 Llc. No.: 888104 (760)777-7125 (760)777-7011 (760) 777-7153 Date: 10/2/2015 LICENSED CONTRACTOR'S. DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations: 9 (commencing with Section 7000) of Division 3 e Business and Professions Code, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect.fflolO on, as provided for by Section 3700 of the Labor Code, for the performance Licen :C4 B C10 A C20 Lic No : 888 0 for which this permit is issued. have and will maintain workers' compensation insurance, as required by Date: Contract of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DEC Tic othe Carrier: _ Policy Number: I hereby affirm under penalty of perjury that I am exempt Contractor's State _ I certify that in the performance of the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree that, if I should become subject to the any structure, prior to its issuance, also requires the applicant for the permit to file a workers' compensation provisions of Section 37 the L r Code, I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division comI ` wi h those rovisio s. 3 of the Business and Professions Code) or that he or she is exempt therefrom and the Date: Applican : basis for the alleged exemption. Any violation of Section 7031.5 by any applicant foe a permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO VERAGE IS UNLAWFUL, ($500).: AND SHALL.SUBJECT AN EMPLOYER TO CRIMINAL PENALTI D CIVIL FINES UP TO ( ) 1, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to within one year of completion, the owner -builder will have the burden of proving that the conditions and restrictions set forth on this application. he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made, each person at whose (_) I, as owner of the property, am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit to construct the.project. (Sec. 7044, Business and Professions Code: The Contractors' issued as a result of this application, the owner, and the applicant, each agrees to, and. State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to the work being performed under or the Contractors' State License Law.). following issuance of this permit. (� I am exempt under Sec. B.&P.C. for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ.'C.). Lender's Name: Lender's I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinanc4andte re. ingto building construction, and hereby authorize representati e n e abov - ione p rty for inspection purpos Date: Signature (Applicant or A , ® • • z x -•.5F r .i ... i..w .. a z .'. ; Y i s f tt s fff` �: vz3'a, s '':v:,. ``"x ^, .-`'z,3s`? i 4,yqk 4?t i4g4fi " a S.r ., F :; ';{ .ziE W FM DESCRIPTION ��t :ACCOUNT s a �p TY Ems' PAID DATE _, .§��a � gz AMOUNT NUM E<: k ' BSAS'SB1473 FEE 161-0600-20306 0 '$2.00 $2.00. 10/2/15 : F x :Yum( �y t.v:z'rtr s' ;� 1` r*z,f bx" � t PAID BY�� �1METHOD € YY ( 1 f "kL. k: i 4S ' 'y,`? `,,, krxa; T5^k.1 & Y^.Tx f- RECEIPTS# #>� 4 ?.iii.«YE.g.=�,�5-�>.3eH.>,Laxm�-�'>a'>$$�`s.T:",>.H. 3CHECK CLTD BY Sad.i-v�.'S5 X3zC.ukY.a.v...w.,:/`ir.: v. ,aav3a::8"*i'a,^'X,-,'= 2015100215364519 ELENA LOYA CREDIT: ' - WEB352. ECON 740 Total Paid for BUILDING STANDARDS ADMINISTRATION 65A:. $2.00 $2.00 . ` "�f"a ?,wa.7't.4y-. i „'•?r, .:ra - : ,.,ia` x+'S' p _ •}2 a(4:%'� _f TYrs t'�: :? � DESGRIPTI ACO NTse', �MOI1fVT PAID a s:t PAID DATE Credit Card Fee 101-0000-43505 0 $4.19 $4.19 10/2/15 -?`3. �'i 5.,.'}e 'fa+x7 PA-..I..D-BY T #+ti5zai�• S:?v. .2n, : rQ�2 i{4uYX.• Lk$£� a YY:_i,C•.a �iC.. P ':xvax.."?'?vrta_a[n__.a�Ed'ev`za.e'Y.:lsF".. >§., _i .:?,''w<" a.'-3 F. ,,ee'x.'..R �3 �s"a+.?:x ...3e.� 2015100215364519740 • ELENA LOYA CREDIT - WEB352 ECON - Total Paid for Credit Card Fee: $4.19 ' $4.19 "€ s-' 01- .4,.: _ k'DESCRIPTIONi W EA?� § .. k.€`- -`:`i ext iz�r:,;..;,;:.s; S<•xi -i.:'e •K- z ACCOUNTS aY"°`'em$'. QTY k"a `:-" AMOUNT= j �PAIDr D e" PAI.WDATE; PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $24.17 10/2/15 <""j4. `M"i ^3. $•::;:w '..('r _Y< <G `.E:x �. £."•i,`.y r ';`�"?':w- > PAID BY ¢ :�a.s,"Y;y`K .w:i�woiXh a METHOD�r �°. S.4 RECEIPT# x z sq�CHECK #�CLTD..BY y� E -n; M' %.?...< . :.xs.'.w:.. ,x'�, ✓. n:.. h^4 . .L� F411, tAx':.€."4:`.:.` r 'TPE.rk..vx: 'F -<<y4 F. x<i ,. 3;-' , ;.: k. s,_Y:..:?,.e:i.rY.'.'+:E...•cL 1, ,Y.>E <�."'�'2'' d..c:§.'".<4F7`L4h."°...:" ..^Y.F1w>v 2015100215364519 ELENA LOYA ''CREDIT WEB352 ECON DESCRIPTION��rµACCOIINT t;� 1Sk{_ .§+E1'.f^ *`:: A=4a' $ X3740 :: %'z:`. .:. "i. 'C `b �.i w AN lia.'s3°`i'e°38F„u" nu' -q ul QTYxAMOUNTPAID tq IT PAID DATE ..:a�z PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600. ' 0 . $24.17 $24.17 10/2/15 ks PAID BYE ,x + METHODS '.z. # a� 'O� CHECK # CLTD BYE n§ :� -RECEIP-T . 2015100215364519 ELENA LOYA CREDIT WEB352740 ECON DESCRIPTION" ' vW Fa"'> ',...i x:?£3xY:OkA -3`s°?i'"a' ACCOGNT t :xF•da iYy>;x Fig��"Ws?.-.x`?'� -. �"-�;';.� f x "PAID a a':wp.;e>..,`" PAID DATE.� S -:v PV SYSTEM - MISC EQUIPMENT 101-0000-42403�p- 0 " $24.17, $24.17 10/2/15 PLAID BYE^>..,., dpMETHO.D41 RECEIPTS# #r CLT;D.BY �£ ` :.srY, kY sk>.,. ,, >�CHECK s 2015100215364519: ELENA LOYA CREDIT " WEB352 ECON 740 ',.',S�.wi '>4q,>,;,j` �''. asS. ,.::.(; ri F -f. ,('"'? �F`v�`435' rOESCRIPTION��g*��, 3•u<: ws".; sil .t��,t°F>.1 ACCOUNT�t .,,` ,s> ka .3"Y .54:..`c Z��,Ei�'a'`'x.�...>:. x QNB AMOUNTPAID' r 4.. ry PAIDID ATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-4260r,0 _ 0 $24.17 $24.17 10/2/15 PQID;BY F'eEiK: ><? METHOD S?r,<a'4t R ECEIPT # _ = g CHECK # CLTD BYq' ,. 4r 4'.:'zv r`✓.r,avx:.>:.,af-..:(-v: ,-,.d-:S' .+E n.H-W r"Hf:S•4`�,' aw_."'btOu .?i?n+=35Y(.e.?,^kaie.T'::.�..a<LT.ro'#S..d_.'m.^.;:v>n-. w , 2015100215364519 ELENA LOYA 'CREDIT WEB352 ECON ' . 740 t ' Total.Paid for ELECTRICAL: : $96.68 $96.68 :�§5 r.'.:.Cf:7�5�`�Sti'Pf -> �'.'t's,if-§iE:2v"93aE ;11 . NU DESCRIPTION ¢i ACCOUNT QTY .4r. AMOUNT § ^✓y. <f -t;.. � c n -; PAID 5s PAID DATE} r� -<-`.' ..F,<; 3 F 3'i', _ `. .a4.CaT.�:s. rCJ:...:_ ? x tfii F' S.ciz c..<ai,. Wi.. ,v a._sC.,,f�i#� :» ,<seE, PERMIT ISSUANCE 101-0000-42404 0 " $91.85 $91.85 ..a 10/2/15 ..� '?z '. • :dv..iS., y B iK ,^ 46 sE._' ,;..i '.£'i '' PAIDbBY,f �a-' 3"'�=',,..' , :-3�%i:`fgy .. r-�`+^_,-a'x ,xvFSz..�,, = 4' METHOD" t,� '''"�.r ° A§w�"°"'x }*''S,,: t of �gRECEIP:T�# 'i>Sk..�'S-'e"T ,zr��, •vi -'Y'.' --^i... �.:r�.r ,>La:..: •' :_.-„.>x.. s ly„' tFa°� �s:��;r:r a �..:.:,..::�e��:. ,�..x w.r;�i:�re�>t>aa��A��'�';�'� Y :�.M iia'�'� CHECK #y :?� s. CLTD BX x ROW, "M 2015100215364519 ' ELENA LOYA - CREDIT � WEB352 ECON .740- Total Paid for PERMIT ISSUANCE: $91:85 $91.85 e Description: BAILIN/14.575 kW PV SYSTEM- (55)265W PANELS/(2) INV+125A SUB Type: SOLAR Subtype: Status: ISSUED Applied: 9/8/2015 MFA Approved: 10/1/20151FU Parcel No: 604081032 Site Address: 44030 SWEETBUSH LN LN LA QUINTA,CA 92253 Subdivision: TR 22982 Block: Lot: 115 Issued: ONLINE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $32,211..00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No, Stories: 0 No. Unites: 0 Details: 14.575 kW SOLAR ARRAY - (55) 265W KYOCERA KU2656ZPA PANELS W/ (1) ABB PVI-5000-OUTD-US-Z-A INVERTER + (1) ABB PVI -6000 -OUTD-US-Z-A INVETER + 125A LOAD CENTER + MAIN BREAKER DERATE TO 150A [990SF] 2013 CALIFORNIA ELECTRICAL CODE. 23, __j Applied to Approved Printed: Friday, October 02, 2015 9:20:13 AM 1 of 3 SYSTEMS CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTIFIED ELENA W/ SOLAR CITY THAT PLAN REVIEW WAS E-MAIL JAKE FUSON 9/15/2015 9/15/2015 COMPLETE AND RIVISIONS WERE REQUIRED. NOTIFIED ELENA W/ SOLARCITY THAT PLANS WERE E-MAIL JAKE FUSON 10/1/2015 10/1/2015 APPROVED AND PERMIT WAS READY TO ISSUE. PLAN CHECK SUBMITTAL MARY FASANO 9/8/2015 9/8/2015 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 9/24/2015 9/24/2015 RECEIVED CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)285-4688 Printed: Friday, October 02, 2015 9:20:13 AM 1 of 3 SYSTEMS Printed: Friday, October 02, 2015 9:20:13 AM 2 of 3 SYS7Fti1S FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # 'METHOD PAID BY CLTD BY 201510021 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON 0 Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $2.00 BSA: 201510021 Credit Card Fee 101-0000-43505 0 $4.19 $4.19 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON 0 Total Paid for Credit Card Fee: $4.19 $4.19 201510021 PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $24.17 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON FIRST 20 0 201510021 PV SYSTEM - ARRAY, 101-0000-42600. 0 $24.17 $24.17 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON FIRST 20 PC 0 201510021 PV SYSTEM - MISC 101-0000-42403 0 $24.17 $24.17 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON EQUIPMENT 0 201510021 PV SYSTEM - MISC 101-0000-42600 0 $24.17 $24.17 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON EQUIPMENT PC . 0 Total Paid for ELECTRICAL: $96.68 $96.68 Printed: Friday, October 02, 2015 9:20:13 AM 2 of 3 SYS7Fti1S DESCRIPTION ACCOUNT QTY AMOUNT PAID' PAID DATE RECEIPT# CHECK # METHOD PAID BY CLTD BY. STATUS REMARKS NOTES NON-STRUCTURAL - 1 WK JAKE FUSON 9/8/2015 9/15/2015 9/15/2015 201510021 CORRECTIONS.pdf SEE 1ST REVIEW CORRECTIONS AND REDLINES. 2ND BLDG NS (1 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 10/2/15 WEB352 536451974 CREDIT ELENA LOYA ECON 0 Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS:•4 .72 13ON6 INFORMATION Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION PATHNAME SUBDIR REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES NON-STRUCTURAL - 1 WK JAKE FUSON 9/8/2015 9/15/2015 9/15/2015 REVISIONS REQUIRED CORRECTIONS.pdf SEE 1ST REVIEW CORRECTIONS AND REDLINES. 2ND BLDG NS (1 JAKE FUSON 9/24/2015 10/1/2015 10/1/2015 APPROVED REVIEW REDLINES.pdf WK) j 13ON6 INFORMATION Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED . BSOL2015-0173 - 1ST DOC 9/15/2015 JAKE FUSON 1ST REVIEW REVIEW 0 CORRECTIONS CORRECTIONS.pdf DOC 9/15/2015 JAKE FUSON 1ST REVIEW REDLINES BSOL2015-0173 - IST 0 REVIEW REDLINES.pdf Printed: Friday, October 02, 2015 9:20:13 AM 3 of 3 SYS TF. NiS ABBREVIATIONS I ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL -WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: La Quinta ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE UTILITY: Imperial Irrigation District I d�"7;1i1 8 R ••b " r' CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB -9224190 0 0 PREMISE DWNEI�. CONTAINED SHALL NOT BE USED FOR THE BAILIN, LORA BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 44030 SWEET BUSH LN PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES LA QUINTA CA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (55) KYOCERA # KU2656ZPA�: SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. Multiple Inverters (760) 285-4688 VICINITY MAP in BAILIN RESIDENCE 14.575 KW PV ARRAY TMK OWNER: * PAGE NAME: COVER SHEET CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION :IF Ass es.SCR's copy MEOW INDEX PVI COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS � Yqv PV5 THREE LINE DIAGRAM + PV6 ELECTRICAL CALCULATIONS PV8 ON LINE DIAGRAM CALCULATIONS `. Cutsheets Attached a; M REV BY DATE COMMENTS REV A * NAME DATE COMMENTS x x x * x * * DESIGN: Dhairya Parikh _\O�SOlaI CIty 'WOO' ✓ SHEET: REV: 3055 Clearview Way DATE Son Mateo, CA 94402 P V 1 T:(650) 638-1026 F:(650) 638-1029 7/30/2015 (686)—SOL—CITY (765-2489) www.solarcity.com PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY. SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (271/2" EMBED, MIN) (E) RAFTER 51 STANDOFF INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. (2)F- 2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. SIDE VIEW OF MP1 NTS l H MPl I X -SPACING I X -CANTILEVER Y -SPACING I Y -CANTILEVER NOTES LANDSCAPE 48" 1 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 175 PITCH 24 STORIES: 2 ARRAY AZI 175 PITCH 24 BOT CHORD 2x4 @24" OC Comp Shingle (-B�_ SIDE VIEW OF MP2 NTS MP2 I X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 1 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 355 PITCH 24 STORIES: 2 ARRAY AZI 355 PITCH 24 BOT CHORD 2X4 @24" OC COmD Shingle C SIDE VIEW OF MP3 NTS MP3 X -SPACING X=CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" ULNu Dhairya Parikh PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 265 PITCH 24 STORIES: 2 ARRAY AZI 265 PITCH 24 Comp Shingle CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER JB -9224190 00 PMMU uwntn: ULbMyllurc BAILIN, LORA BAILIN RESIDENCE 44030 SWEET BUSH LN 14.575 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME: (760) 285-4688 STRUCTURAL VIEWS ULNu Dhairya Parikh N-44% A?, SolarCit �,1 y. MOUNTING SYSTEM: Comp Mount Type C n MODULES: (55) KYOCERA # KU2656ZPA 3= geanAew Way sem, Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com SHEET: �µ ppb PV 3 7/30/2015 INVERTER Multiple Inverters CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -9224190 CONTAINED SHALL NOT BE USED FOR THE Risk Category: • PV System Type Comp Roof BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS L ers of 1150—mpRoofing ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (55) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. Multiple Inverters 00 PREMISE OWNER: BAILIN, LORA 44030 SWEET BUSH LN LA QUINTA, CA 92253 (760) 285-4688 UPLIFT CALCULATIONS 07.30.2015 �` PV System Structural Version #48.9 ;;,SolarGty. Desi a n Software Project Information & Table Of Contents Risk Category: • PV System Type Comp Roof II Sola�City,SleekMount- Comp Roof L ers of 1150—mpRoofing 2 Roof Slope Rafter S acro _ 240 24" O.C. PV System Module Orientation PV, Module Area PV Module Width PV Modula Length Standoff Attachment Hardware Landscape and Portrait 974 sf 39" ' 65" Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load Surrounding Roof Snow Roof Snow Over PV Modules 0.0 psfASCE 0.0 psfASCE 0.0 psf Table 7-1 Eq: 7.4;1 ASCE Eq: 7.4-1 Wind Desi n•Criteria _ Wind Design Code Wind Design Method Basic Wind Speed Exposure Category Roof Style Mean Roof Height Effective Wind Area 1 Module ASCE 7-10 Partially/FulgEndosed Method 110 mph C Gable Roof V Fig. 26.5-1A Section 26.7 ag: 30.4-2A/B/C.SA/B Section 26.2 _ IBC 1509.7.1 h 25 ft 17.7 sf A Wind Pressure Calculation Coefficients Wind Pressure Exposure Topographic Factor Wind Directionality Factor Im ortance FactFactor K2 0.95 Table 30.3-1 ,Section 26.&_ _.Section 26.6-1_ 1.00 —KA— Kd 0.85. I NA. Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 24.9 psf Equation 30.3-1 Ext. _Pressure Coefficient (Up)�, Ext Pressure Coeffident Down �GCp (Up) T GC Down -0.88 Rg. 30.4-2A/0/C-5A/B 0.45 Fig. 30.4-2A/e!C-5A/B Design Wind Pressure P p = gh GC Equation 30.4-1 Wind Pressure Up Wind Pressure Down p(up) down -21.8 psf 16.0 psf Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing_ Max Allowable. Cantilever NA -Standoff Confi uon Landscape 72" 39" `Landscape_ Landsca a 24" — Not -Staggered Max Standoff Tributary, Area PV Assembly Dead Load Net Wind Uplift at Standoff Uplift Capacity of Standoff Standoff Demand/Capacity Trlb 19 sf W -PV 3 psf Tactual^ T -allow -ZZ3 lbs 500 lbs, DCR 44.5% Max Allowable Standoff Spacing Max Allpwable Cantilever T ^' Standoff configuration Portrait 48" 65" ,Portrait— Portrait 20" _ _ NA, Not -Staggered Max Standoff Tributary, Area PV Assembly Dead Loady Net Wind Uplift at Standoff Uplift Capacity of Standoff Standoff D—emOd/Cipacity Trib 1-22-sf W -PV 3 psf T•-actual _ T -allow -249 a 500 lbs DCR 49.8% BAILIN RESIDENCE 14.575 KW PV ARRAY PAGE NAME: UPLIFT CALCULATIONS Dhairya Parikh SHEET: REV. DATE- PV AISPV 4 - 7/30/2015 ISM SolarCity. w40 3055 aeaMew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (686) -SOL -CITY (765-2489) www.sdarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 44030 Sweet Bush Ln UTILITY SERVICE AC DISCONNECT INVERTER AND DC DISCONNECT INVERTER AND DC DISCONNECT r--------------------------� SOLAR- PHOTOVOLTAIC ARRAY(§) PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9224190-00 CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER JB -9224190 0 0 SSE OWNER: DESGRIPIIION: BAILIN, LORA BAILIN RESIDENCE 44030 SWEET BUSH LN 14.575 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME (760) 285-4688 SITE PLAN PLACARD DESIGN: Dhairya Parikh •�� �;,;So�arCity MOUNTING SYSTEM: Comp Mount Type c �/� ' , �J`� c MODULES (55) KYOCERA # KU2656ZPA 3055 Cleorview Way Son Moteo, CA 94402 638-1026 F:(650) 630-1029 (888)—SOL—CITY (765-2489) www.solarcity.eom SHEET: REV DATE PV 7 7/30/2015 INVERTER:T.(650) Multiple Inverters Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR �`wwe 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED .49•.■ San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set 0�"' T:(650) 638-1028 F:(650) 63&1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I' S01a[C�ty-1(888}SOL-CUY(765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. `'tSolarCity Z pSolar Zep System for composition shingle roofs Q,Ot4P4t'6 p00MPO �L LISTED C� zepsolar.com Next -Level PV Mounting Technology Ground Zep _ Interlock (Nnysided,arnt �-_� .-,_w Leveling Font - '--•. �1 ^ Ii i. S.. r -.. i Zep Compaliblu PV Module r \ - - .. ZcP Grave ._ Roof Attudiment — KraySkirt Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 ' SolarCity ZepSolar Components zepsolar.com Next -Level PV Mounting Technology Comp Mount Part No. 850-1382 Listed to UL 2582 & Mounting Block to UL 2703 'f) . Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 Interlock Leveling Foot Part No. 850-1388 Part No. 850-1397 Listed to UL 2703 Listed to UL 2703 Array Skirt, Grip, End Caps DC Wire Clip Part Nos. 500-0113, Part No. 850-1448 850-1421, 850-1460, Listed UL 1565 850-1467 Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 Designed for residential and small commercial PV installations, this inverter fills a specific niche in the ABB product line to cater for those installations producing between 5kW and 20M This inverter includes dual input section to process two strings with independent MPPT. The high speed and precise MPPT algorithm offers real-time power tracking and energy harvesting. Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. AD The wide input voltage range makes the inverter suitable to low power installations with reduced string size. The transformerless operation offers high performance efficiencies of up to 97.1%. Free remote monitoring capability available with every installation. This enables homeowners to view their energy production and offers installers a proactive and economic way of maintaining and troubleshooting the system. t Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted -use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity M OD OD for a better world''PI OD OD Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and ` Interruption (-A Version). Technical data and types 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers i • Easily accessible grounding puilils on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters 1 • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections ' PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average i output of any crystalline module ! • First module manufacturer in the world to pass long- term sequential testing performed by TUV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 QtoMPAT4d H `� C UL US �AOOMPON'\ KU -60 1000V Z Series KU265-6ZPA HIGH EF,F,IGIENCY M-U-LTI_CRYSi AL PHOTOVOLTAIC MODULE S;O_LTA�RR KQO_G_E_9W KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS x Cells per module: 60 (6 x 10) III Dimensions: 65.43ini38.98ini 1.57in KU2length/wid"eight • (1662mmi990mmi40mm) P 265 W Weight: 45.2lbs (20.5kg) v 31.0 v PACKAGING SPECIFICATIONS _-- -- - ----- — _ IOP 8.55 A Modules per pallet 20 V. 38.3 V Pallets per 53' container. 36 _ Pallet box dimensions: 66ini40ini43in lu 9.26 A length/width height (1675mm/1005mm/1055mm) PtaeaMe +5/-0 % Palletboxweight 1015lbs(460kg) toNOW . . o • :11 I' 1.57" 45 °C POTTED N 191 W JU JUNCTTION iVaP� r CL 27.9 V J CABLE W/ CONNECTOR Imp 6.855 A LABEL V� 35.1 5 6 u 7.49 A _ a I PTC 238.1 W238.1 WW P_ -0.45 %/°C V.P -0.48 %/°C 1 0.02 � %�°C _ V � -- -0.36 _ %�°C 38.98- (9901on) �I 0.06 � %J°C Operating Temp -40 to +90 °C Grounding role Slotted Haunting role 0.16- (4md 0.35'.0.47- (ge,rsl2m0 FRAME CROSS SECTION DIAGRAM Series Rating 15 A o. u na>m -Fuse – � —� Maximum DC System Voltage (UL) 1000V Hailstone Impact in (25mm) @ 51 mp (23m/s) II 6 It31\� 'Subject to simulator measurement uncertainty of +l- 3%. 1.3g-t75vo1 KYOCERA reserves the right to modify these specifications without notice. LONG/SNORT SIDE WARNING: Rcad the insUuclion I, manual in its rnlirety prior to ♦I handling, installing BopMat- ing Kyocera solar modules. 040215 OUR VALUED PARTNER KYOCERA Solar, Inc. 800 2243 9580 800 528 2329 fax www.kyocerasoIar.com Switching Devices Q •1 1 Safety Switches �J DG321NRB 120/240 Vac General -Duty, Fusible, Single -Throw, continued - — UG321UGO0 Maximum Horsepower Retings0 NEMA 1 NEMA 3R Ampere Single -Phase AC Three -Phase AC DC NEMA1 NEMA 3R Ampere Fuse Type Single -Phase AC Three -Phase AC DC Enclosure Indoor Enclosure Rainproof System Rating Provision 120V 240V 240V 250V Catalog Number Catalog Number Cartridge Type—Three-Pole, Three -Wire (Three Blades, Three Fuses) -240 Vee OG221UG80 OG221URB0 �x d b bbJ 30 — — — — — o 0 ..J 60 o O loo — — — — — 0 0 I 200 — — — — — O O 400 H — — 50-125 — DG325FGK00 OG325FRKib Boo H — — 75-200 — OG326FGK00 OG326FRK00 Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac 82113'12023 30 H — 1-1/2-3 3-7-1/2 — OG321NGB OG321NRB p p p 60 H — 3-10 7.1/2-15 — DG322NGO OG322NRB jjh' jTh' jhT' e+ 100 H 7-1/2-15 15-30 DG323NGB DG323NRB 200 H — 15 25-60 — OG324NGK DG324NRK 400 H — — 50-125 — OG325NGK DG325NRK 600 H — — 75-200 — OG326NGK OG325NRK OG322URB 120/240 Vac General -Duty, Non -Fusible, Single -Throw 3 7-1/2 — UG321UGO0 Maximum Horsepower Ratings NEMA 1 NEMA 3R Ampere Single -Phase AC Three -Phase AC DC Enclosure Indoor Enclosure Rainproof System Rating 120V 240V 240V 250V Catalog Number Catalog Number Two -Pole, Two -Wire (Two Blades) -240 Vac Iff�j 15 60 — OG324UGK0 I 30 2 3 — — o/ OG221UG80 OG221URB0 60 3 10 — — UG222UGBt•r OG222URB t1t q q 100 — 15 — — OG223UGOO OG223URB0 200 — — — — 00 (DD Three -Pole, Three -Wire (Three Blades) -240 Vac 30 2 3 7-1/2 — UG321UGO0 OG321URB0 �1 1 3 1 General Duty Safety Switch 1hterru for de Y Y Igo 5 30 — OG323UGB0 OG323URB0 200 — 15 60 — OG324UGK0 OG324URK0 400 — — 125 — DG325UGK0 OG325URK0 600 — — 200 — OG326UGKCD OG326URK0 Notes (D Maximum hp ratings apply only when dual element time delay fuses are used. O Use four -wire catalog numbers below. O Solid neutral bars are not included. Order separately from table on Page 15. 01 WARNING! Switch is not approved for service entrance unless a neutral kit is installed. 01 Use three -wire catalog numbers below. O Drilled to accept field installed neutral kits. All general -duty safety switches are individually packaged. Accessories are limited in scope on general -duty safety switches. See Page 15 for availability. In addition, clear line shields are available as an accessory on 200-600A general -duty switches. Catalog Numbers: 200A = 70-7759-11, 400A = 70.8063-8.600A = 70-8064-8. Volume 2—Commercial Distribution CA081000O3E—February2011 www.eaton.com - 27 E:T• N" 1Da*A9.qeosinessWo MWV" 30A. DG221URB 240A. General Duty Safety Switch 1hterru for de se uridad servicio li ero 2 Pole Non -Fusible fusibles Series: series: B pry; cane.: 1 polos sin T pe 3R Rainproof r ! KECKOEE INNEr.A. p EMA) Tipo 3R a prueba de LI " 09/18/2012 SS31430 U� 7 82113'12023 2 t 4 I 3 2 11 rr,I h DI .281 [5.5 KNOCKOU QUANTITY 1 6.89 (175) 5.73 [1 CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 3/4 CONDUIT 1/2, 3/4 CONDUIT QTY 2 QUANTITY 4 276.8 DIA. 3 M UN ING HOLES N Of B m NGENTIAL KNOCKOUTS FOR '2, 3/4, 1 CONDUIT . IANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) 'ARE SHOWN IN BRACKETS. 2. WIRE RANGE. OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM NEUTRAL #4—#14 COPPER OR ALUMINUM A >ti[mortmr or urox a>avaurox WgRREN SPE 819 98 CUTLER -HAMMER s � "wanxt "w PRTSBURGH PA. w"us ro® Ix Ana nd- R. PRGHASKA 8/119/98 ^� DIMENSION SHEET n om " m s ruaa�m. — 30 AMP TYPE 3R GENERAL DUTY 95-1445.DWG 55740GC1 I-2 I a c -i-95-1445I of I 2 1 I 0 N N O .281 [5.5 KNOCKOU QUANTITY 1 6.89 (175) 5.73 [1 CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 3/4 CONDUIT 1/2, 3/4 CONDUIT QTY 2 QUANTITY 4 276.8 DIA. 3 M UN ING HOLES N Of B m NGENTIAL KNOCKOUTS FOR '2, 3/4, 1 CONDUIT . IANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) 'ARE SHOWN IN BRACKETS. 2. WIRE RANGE. OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM NEUTRAL #4—#14 COPPER OR ALUMINUM A >ti[mortmr or urox a>avaurox WgRREN SPE 819 98 CUTLER -HAMMER s � "wanxt "w PRTSBURGH PA. w"us ro® Ix Ana nd- R. PRGHASKA 8/119/98 ^� DIMENSION SHEET n om " m s ruaa�m. — 30 AMP TYPE 3R GENERAL DUTY 95-1445.DWG 55740GC1 I-2 I a c -i-95-1445I of I 2 1 I S.• ®ZS COMP I GROUNDING AND BONDING Zep Solar ZepSolar ZS Comp'" I Grounding and Bonding This document describes the mechanics of how the electrical bonding is accomplished between the UL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Zep Compatible`" systems do not require running copper conductors to each module. The act of physically installing each component simultaneously establishes an electrical bond, as described in the following pages. Document 800-1478-001 Rev A www.zepsotar.com PAGE: 1 of 5 m 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25,20134:45 PM Interlock Interlock Zep UL Listed to Tongue side Key Side Bonding Cutting'tooth' Keyside in `�✓ closed position Cutting "tooth Tongue Side Bonding Tongue side in closed position Cutting 'teeth' Side view Interlock Module r,® Bonding locations Li on Key side Forced interference during rotation of Interlock Zep causes teeth to cut through anodization on module frame, resulting in robust and UL certified bonding path Module O n lam/ in I Forced interference between mating parts from module Bonding location on rock -in motion cuts into module frame, removing Tongue side anodization and resulting in robust and UL certined bonding path Document 800-1478-001 Rev A www.zepsciar.com PAGE: 2 of 5 © 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 20134:45 PM 0_ ZepSolar Interlock, continued Part No. 850-1388 UL Listed to UL 2703 Bonding Path - Key and Tongue Module ZS COMP I GROUNDING AND BONDING The Interlock bonds modules on all 4 sides to create a hyper- hondedarray where every module Is structurally and electrically bonded to the surrounding modules. Bonding Path - Array o Interlock Bonding path Down -roof Tongue side Key side Document 800-1478-001 Rev A www.zepsotar.com PAGE: M5 5 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25.20134:45 PM ®. ZepSolar Leveling Foot Part No. 850-1397 UL Listed to UL 2703 ZS COMP I GROUNDING AND BONDING Tongue side .4 -------- 4� Key side The Leveling Foot top portion (the Rockit) has a stainless steel spring clip that bonds to the adjacent module frame on both Key and Tongue sides. Leveling Foot - Bonding With Module Frame Down -roof Z O Key side Inserts into Zep Groove (rock -in) Module in next row drops in on the Tongue side Bonding Path - North and South Modules Spring clip Bonding location on Key side Bonding location on Module rotation during drop-in creates forced _,,-- Down -roof Tongue side interference between Zep Groove and spring clip, cutting into module frame, removing anodization and resulting in robust and UL certified bonding path Document 800-1478-00I Rev A www.zepseLar.com PAGE: 4 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved Date Last Exported: June 25,20134:45 PM Leveling Foot - w ® ® Bonding path`J N d d N N N Spring clip Bonding location on Key side Bonding location on Module rotation during drop-in creates forced _,,-- Down -roof Tongue side interference between Zep Groove and spring clip, cutting into module frame, removing anodization and resulting in robust and UL certified bonding path Document 800-1478-00I Rev A www.zepseLar.com PAGE: 4 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved Date Last Exported: June 25,20134:45 PM �. ZepSolar ZS COMP I GROUNDING AND BONDING Ground Zep Set screw Part No. 850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation Key side Ground wire channel The Ground Zep provides a single point of connection for the Equipment Grounding Conductor (EGC) from the array to a building ground. 6-1 - �(Iou �l Insert Ground Zep Into Zep Groove of module frame, Use the Flat Too to rotate the Ground Zep 90 degrees, so that setscrew Insert copper EGC into ground wire on array perimeter is pointing straight up. channel. Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground OGround Zep Equipment Ground �— Conductor Bonding path 1 Dowh-roof Document 800-1478-001 Rev A www.zepsolar.com PAGE: W5 5 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 20134:45 PM SolarCity Standard Box Q The SolarCity Standard Box 4J is a 4 -String unfused Junction Box. The box is highly configurable and adaptable using the (4) jumper blocks included in each box. A factory installed cordgrip enhances installer productivity. S®1x11 Y ty0 October 2013 • Manufactured to meet UL 1741 Standards. • Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. • Factory -Installed Cordgrip Enhances Installation Speed. • Break-Thru Skinned -Over Glands on Cordgrip Provide Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. Technical Data / Specifications Q Voltage Rating [VDC] : 600V © Maximum DC Current [A]: 57A © Maximum Continuous Current [A]: 42A ®D Maximum Voltage [VDC]: 600V ©E Wire Size Range [AWG]: #6 to #14 Enclosure Rating: NEMA 4X © Operating Temperature Range [°C]: -40 to 50 %:J Typical Overall Dimensions [in]: 8"x6"x4" NOTICE OF COMPLETION UL AND AUTHORIZATION TO APPLY THE UL MARK 12/21/2013 Solarcity Corp Alex Yang 3055 Clearview Way San Mateo Ca 94402-3709, Us Our Reference: E318537, Volume 1 Project Number 4786083586 Your Reference: A.Yang 10/7 Project Scope: Investigation of Photovoltaic (PV) System Combiner Box, model "SolarCity Standard Box 4C" and Photovoltaic (PV) System Transition Box, model "SolarCity Standard Box 4J" to UL 1741 Standard. ` Dear Alex Yang Congratulations! UL's investigation of your product(s) has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow -Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's Follow -Up Service Program. To provide your manufacturers) with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537, Volume 1 - and including any special instructions asindicated in the addendum to this letter. Records in the Follow -Up Services Procedure covering the product are now being prepared and will be sent in the near future. Until then, this letter authorizes application of the UL Mark for 90 days from the date indicated above. Additional requirements related to your responsibilities as the Applicant can be found in the document "Applicant responsibilities related to Early Authorizations" that can be found at the following web -site: httb:t/ w,ul:com/EAResoonsibiliiies Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. Very truly yours, Reviewed by Jon Adonay William R. Carney 408-7546630 847/664-1088 Engineering Associate Lead Chief Engineer Director I Jon:Adonay@ul.com William.R.Carney@ul.com NBKD9C5-90BA67 This is an electronically generated letter. Signatures are not required for this document to be valid. Page 1 of 1 q}y A :i► A � a• �P 1 In S®1x11 Y ty0 October 2013 • Manufactured to meet UL 1741 Standards. • Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. • Factory -Installed Cordgrip Enhances Installation Speed. • Break-Thru Skinned -Over Glands on Cordgrip Provide Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. Technical Data / Specifications Q Voltage Rating [VDC] : 600V © Maximum DC Current [A]: 57A © Maximum Continuous Current [A]: 42A ®D Maximum Voltage [VDC]: 600V ©E Wire Size Range [AWG]: #6 to #14 Enclosure Rating: NEMA 4X © Operating Temperature Range [°C]: -40 to 50 %:J Typical Overall Dimensions [in]: 8"x6"x4" NOTICE OF COMPLETION UL AND AUTHORIZATION TO APPLY THE UL MARK 12/21/2013 Solarcity Corp Alex Yang 3055 Clearview Way San Mateo Ca 94402-3709, Us Our Reference: E318537, Volume 1 Project Number 4786083586 Your Reference: A.Yang 10/7 Project Scope: Investigation of Photovoltaic (PV) System Combiner Box, model "SolarCity Standard Box 4C" and Photovoltaic (PV) System Transition Box, model "SolarCity Standard Box 4J" to UL 1741 Standard. ` Dear Alex Yang Congratulations! UL's investigation of your product(s) has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow -Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's Follow -Up Service Program. To provide your manufacturers) with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537, Volume 1 - and including any special instructions asindicated in the addendum to this letter. Records in the Follow -Up Services Procedure covering the product are now being prepared and will be sent in the near future. Until then, this letter authorizes application of the UL Mark for 90 days from the date indicated above. Additional requirements related to your responsibilities as the Applicant can be found in the document "Applicant responsibilities related to Early Authorizations" that can be found at the following web -site: httb:t/ w,ul:com/EAResoonsibiliiies Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. Very truly yours, Reviewed by Jon Adonay William R. Carney 408-7546630 847/664-1088 Engineering Associate Lead Chief Engineer Director I Jon:Adonay@ul.com William.R.Carney@ul.com NBKD9C5-90BA67 This is an electronically generated letter. Signatures are not required for this document to be valid. Page 1 of 1