BOTH2015-000978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BOTH2O15-0009 Owner: . Property Address: 78150 CALLE TAMPICO DUNCAN SMITH APN: 770020024 17 ARDENDALE CT Application Description: PLAZA TAMPICO CELL MODIFICATION ALAMO, CA 92253 Property Zoning: Application Valuation: $15,000.00 r„� r-. 111111 Illil IIII IIII ,9 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/19/2016 Applicant: L -1I - Contractor: SMARTLINK LLC N q THE W CORPORATION DBA VANTAGE COMPANY 18401 VOIN KARMAN AVE STE 400. FEB 19 2016 1643 W ORANGE GROVE AVE IRVINE, CA 92612 CITYOFi4�l`I�._._,ORANGE, CA 92868 CCillit�°.TrOE+ELt�°:'E L�i'jvT (714)532-8800 Llc. No.: 799597 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. A License No.: 799597 Spate: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the f basis for the alleged'exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his *or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (__) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's N Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 I have and will maintain workers' compensation insurance, as required by Se0n 3700 of the Labor Code, for the performance of the work for which this permit is issued.{vly,workers' compensation insurance carrier policy number are: Carrier S Policy Number:_ ]-certify that in the performance of the work for which this permit is issued, I s _ ]-c _. shalFnot'employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. %! 7 'Y WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT' IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall.defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the - above -mentioned property for inspection purposes.s Dates Signature;(Appliean"t or Ag DESCRIPTION :. FINANCIAL INFORMATION ACCOUNT.:' QTY "AMOUNT PAID PAID DATE ANTENNA, DISH 101-0000-42404 0 $108.78 $108.78 2/19/16 PAID BY METHOD RECEIPT # CHECK # . CLTD BY THEODORE F HALSEY DEBIT MR267 RSE DESCRIPTION, ACCOUNT QTY 'AMOUNT' ' PAID PAID DATE ANTENNA, DISH PC 101-0000-42600 0 $400.29 $400.29 2/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY., : THEODORE F HALSEY DEBIT MR267 RSE Total Paid for ANTENNA: $509.07 $509.07 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 2/19/16 PAID BY METHOD RECEIPT #, CHECK # CLTD BY THEODORE F HALSEY DEBIT MR267 RSE Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPTION .:A000UNT . QTY. AMOUNT: PAID . PAID DATE STORAGE RACKS, FIRST 100 LF 101-0000-42404 0 $24.66 $24.66 2/19/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY THEODORE F HALSEY DEBIT MR267 RSE DESCRIPTION ACCOUNT QTY AMOUNT '` PAID ,PAID -DATE STORAGE RACKS, FIRST 100 LF PC 101-0000-42600 0 $95.72 $95.72 2/19/16 PAID BY METHOD RECEIPT # CHECK # . CLTD BY THEODORE F HALSEY DEBIT MR267 RSE Total Paid for STORAGE RACKS: $120.38 $120.38 TOTALS: $630.45 $630.45 Description: PLAZA TAMPICO CELL MODIFICATION Type: STRUCTURE OTHER THAN Subtype: Status: APPROVED -CONDITIONS Applied: 12/15/2015 MFA BUILDING Approved: Parcel No: 770020024 Site Address: 78150 CALLE TAMPICO LA QUINTA,CA 92253 Subdivision: PM 27109 Block: Lot: 1 Issued: Lot Sq Ft:.O Building Sq Ft: 0 Zoning: Finaled: Valuation: $15,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 2/8/2016 Details: MODIFICATION OF EXISTING WIRELESS TELECOMMUNICATIONS FACILITY TO ADD 3 ADDITIONAL ANTENNAS (1 PER SECTOR). MINOR USE PERMIT APPROVAL REQUIRED, SEE MUP2015-0012 FOR APPROVAL FROM PLANNING MUP2015-0012 APPROVAL LETTER RECEIVED. ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES . LETTER BURT HANADA 2/8/2016 2/8/2016 MUP2015-0012 APPROVAL LETTER RECEIVED FROM W. NESBIT. NOTE AJ ORTEGA 1/6/2016 1/6/2016 MINOR USE PERMIT APPROVAL REQUIRED, SEE MUP2015- 0012 FOR APPROVAL FROM PLANNING PRIOR TO ISSUANCE.' NOTE MARY FASANO 12/15/2015 12/15/2015 PLANNING NEEDS TO APPROVE THE MINOR USE PERMIT MUP2015-0012 BEFORE ISSUING THIS PERMIT PLAN CHECK COMMENTS FROM CONSULTANT STEPHANIE GUMPERT 12/29/2015 12/29/2015 RECEIVED TELEPHONE CALL JIM JOHNSON 12/30/2015 12/30/2015 CALLED LUIS CARDONA TO INFORM HIM PLANS ARE READY TO ISSUE. CONDITIONS Printed: Friday, February 19, 2016 8:42:35 AM 1 of 3 i SYSTEMS Printed: Friday, February 19, 2016 8:42:35 AM 2 of 3 r sys•rcMs FINANCIAL CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SMARTLINK LLC 18401 VOIN KARMAN AVE STE 400 IRVINE CA 92612 JMCCOMMELL@SMAR TLINKLLC.COM CONTRACTOR THEW CORPORATION DBA VANTAGE COMPANY 1643 W ORANGE GROVE AVE ORANGE CA 92868 DEBIT THEODORE F HALSEY RSE- SE-ANTENNA, OWNER DUNCAN SMITH 17 ARDENDALE CT ALAMO CA 92253 DEBIT THEODORE F HALSEY RSE Printed: Friday, February 19, 2016 8:42:35 AM 2 of 3 r sys•rcMs FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY ANTENNA, DISH 101-0000-42404 0 $108.78 $108.78 2/19/16 MR267 DEBIT THEODORE F HALSEY RSE- SE-ANTENNA, ANTENNA,DISH PC 101-0000-42600 0 $400.29 $400.29 2/19/16 MR267 DEBIT THEODORE F HALSEY RSE Total Paid for ANTENNA: $509.07 $509.07 BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 2/19/16 MR267 DEBIT THEODORE F HALSEY RSE Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: STORAGE RACKS, FIRST 101-0000-42404 0 $24.66 $24.66 2/19/16 MR267' DEBIT THEODORE F HALSEY RSE 100 LF STORAGE RACKS, FIRST 101-0000-42600 0 $95.72 $95.72 2/19/16 MR267 DEBIT THEODORE F HALSEY RSE 100 LF PC Total Paid for STORAGE RACKS: $120.38 $120.38 TOTALS: Printed: Friday, February 19, 2016 8:42:35 AM 2 of 3 r sys•rcMs IST BLDG NS (2 WK) JIM JOHNSON 1 12/15/2015 12/31/2015 1 12/30/2015 1 APPROVED 1ST BLDG STR (2 .WK) KURT CULVER 12/15/2015 12/31/2015 12/24/2015 READY FOR APPROVAL ETRAKIT ENABLED RnND INFORMATInN Printed: Friday, February 19, 2016 8:42:35 AM 3 of 3 SYSTEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED IST REVIEW BOTH2O15-0009 - 1ST DOC 12/28/2015 AJ ORTEGA STRUCTURAL FEE SHEET REVIEW STRUCTURAL 0 (ESGIL) FEE SHEET.pdf 1ST REVIEW BOTH2OIS-0009 - 1ST DOC 12/28/2015. AJ ORTEGA STRUCTURAL REVIEW STRUCTURAL 1 TRANSMITTAL TRANSMITTAL.pdf DOC 2/8/2016 BURT HANADA MUP2015- MUP2015- 1 0012_Approvalltr.pdf 0012_Approvalltr.pdf Printed: Friday, February 19, 2016 8:42:35 AM 3 of 3 SYSTEMS sin. L. Cltj/ Of- U. QuIon: to BulWirig er Safety Division ' P.O. Box 1504,78-495 Calle Tampico CO ia.Quinta, CA 92253.:(760) 777-7012 Building Permit -Application and Tracking Sheet Permit # Project Addtcss: 78150 Calle Tampico Owner's Name:.Smith Family Trust A P. Number. 7.70-020-024. Address: 17 Ardendale Court Legal Description: City, ST, Zip: Alamo, CA 94.507 Contractor. TBD Telephone: N/A Project Description: Modification of existing wireless Address: City, ST, Zip: telecommunications facility to add 3 additional antennas . Telephone: State Lic. #: (Sty Lic. t. (1 per sector) Arch., Engr., Designer. Breen Engineering Address: 6281 Beach'Blvd. #125 City., ST, Zip: Buena Park, CA 90621 Telephone: 657-529-2'111 Construction Type:. Occupancy: State Lic. #: 54194 Project type (circle one): New Add'n Altar Repair Demo Name of Contact Person: Luis Cardona Sq. Ft.: # stories: # Unitp: Telephone # of Contact Person: 657-529-2111 Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal R 'd Recd TBACMG PERMY FEES Pisa Sets Plan Check submitted item Amount Stroctur'al Calfa Reviewed, ready for corrections Plan Check Deposit. . Truss Calco. Called Contact Person Plan Check Balance - Tithe 24 Calci. Plans picked up Construction Flood plain pian Plans resubmitted .' . Mechanical Giading plan 2id Review, ready for correctionsrissue Electrical Subeontaetor List Called Contact Person Plumbing . Grant Deed Plans picked up S.M.1. H.O.A. Approval Plans resubmitted Grading !iY HOUSE,, '"` Review; ready for carrectionsJissue Developer Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue school Fees Total Permit Fees ,c EsGil Corporation In Partnership with Government for Building Safety DATE: 12/24/2015 ❑ APPLICANT ,& JURIS. JURISDICTION: City of La Quinta ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: BOTH2O15-0009 SET: I PROJECT ADDRESS: 78150 Calle Tampico PROJECT NAME: T -Mobile CM478 Plaza Tampico IE04478A ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted fora complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil Corporation staff did not advise the applicant that the plan check has been completed. ❑ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #:. Date contacted: (by: ) Email: RECEIVED Mail Telephone Fax In Person DEC 2 9 2015 ® REMARKS: structural review only CITY OF OEVELOPMEIdT QUINTA By: David Yao Enclosures: COMMUNE EsGil Corporation ❑ GA ❑ EJ ❑ MB ❑ PC 12/17 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858)560-1468 ♦ Fax(858)560-1576 City of La Quinta BOTH2O15-0009 12/24/2015 ADO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of La Quinta PLAN CHECK NO.: BOTH2O15-0009 PREPARED BY: David Yao DATE: 12/24/2015 BUILDING ADDRESS: 78150 Calle Tampico BUILDING OCCUPANCY: B BUILDING PORTION AREA ( Sq. Ft.) Valuation Reg. VALUE ($) Multiplier Mod. cell site revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Ilq IManual input Bldg. Permit Fee by Ordinance I I Plan Check Fee by Ordinance -W Type of Review: ❑ Complete Review ❑ Repetitive Fee Repeats * Based on hourly rate ❑ Other a—H_ourly EsGil Fee E] Structural Only 2 Hrs. @ $87.15 $217.88 $174.30 Comments: Sheet 1 of 1 macvalue.doc + e�FiC� B R E E N k-7iz, Engineering Inc T -MOBILE IE04478A CM478 PLAZA TAMPICO 78150 Calle Tampico La Quinta, CA 92253 Prepared for Smartlink STRUCTURAL CALCULATIONS Equipment Support September 24, 2015 CITY OF LA QUIN i BUILDING & SAFETY DE { APPROVED FON CONS UCTION i s 1983 W 190th Street, Suite 200 I Torrance, CA 90504 T 310.464.8404 I F: 310.464.8408 I www.breeneng.com orF►(e ctPy a ie>r�s:Tiief eesreersae�e�a i •, �8 -(s0 co Tirtwo trt • �n�trt u' .cis np ".3 .1j;.. 1EIVE® DEC 152015 C17Y OF LA QUINTA COMMUNITY DEVELOPMENT fl Project: T -MOBILE IE04478A Page: 1 Design Criteria I. Code California Building Code, 2013 Edition. ASCE7-10 Minimum Design Loads for Buildings & other structures II. Scope of Work 1. Provide structural review of the proposed addition of (1) antenna mounted on the pipe support in sectors A, B and C. 2. Provide structural review of the proposed addition of (1) RRU unit mounted on the pipe support in sector A, B and C. III. Citation The following documents were provided to Breen for the purpose of generating this report. It is assumed that this information is accurate and correct. Breen shall not be responsible for information/calculations prepared by others or for errors in our design as a result of inaccurate information provided to us. 1. Construction drawings provided by SBA Consulting, Inc. dated 10/04/96. 2. Construction drawings provided by Reliant Land Services dated 01/16/13. IV. Summary STRUCTURAL -PASS Provisions of Analysis & Disclaimer:, The analysis and conclusions contained in this report are based on information provided by T -Mobile. Construction not performed in accordance with the provisions contained herein will void this report. Breen declines any responsibility for damages that originated prior to the proposed modifications/additions or for the accuracy of design/calculations done by other-s-o._or variations in the design and field conditions. Discrepancies between field conditions and this."epa t qtr ul b� Q�� T immediately brought to the attention of Breen for review. vIN BUILDING & SAFETY DEPT. FOR R CONSTRUCTION DATE -_BY Project: T -MOBILE IE04478A Page: 2 4 Proposed Antenna: COMMSCOPE LNX-6513DS-VTM W Antenna Specifications > H=54.9 in W= 11.9 in D = 7.1' in H D Af = 4.5 ft` Ar = 0.6 ft` Gravity Specifications Weight = 26.0 lbs d= 36 in Antenna Eccentricity = 1.5 ft Mounting Brackets Weight = 20.0 lbs Mounting pipes Weight =lil lbs H= in Diameter =in Gravity Load Wp= 64.0 Ibs CI OF L C�UINTq ' BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA,TE�_ BY Wind Design Design Code: California Building Code, 2013 Edition, Chapter 16 ASCE 7-10 Exposure "C" Basic Wind speed = 110.0 mph Height of structure = 42 ft Risk Category II VELOCITY PRESSURE qZ = 0.00256 KZ KZt Kd VZ ASCE 7-10 (29.3-1) psf qz (MIN.) = 16.0 psf WIND LOAD Fh = qh (GCr) Af ASCE 7-10 (29.5-2) 52.7 psf 31.6 psf (ASD) F„ = qh (GCr) A, ASCE 7-10 (29.5-3) 41.6 - psf 25.0 psf (ASD) where KZ =2.01 ( Z / Z9 )2/° = 1.05 KZt = 1.0 Kd = 0.85 V = 110.0 GCr = 1.9 for latheral force GCr =.I 1.5 for vertical uplift Project: T -MOBILE IE04478A Page: 3 CITY OF------ BUILDING &L q QU(NTA Y DEPT APPROVED FOR CONSTRUCTION DATE -_BY _ Project: T -MOBILE IE04478A Seismic Design Fseismic = (KH) MAX (0.3 SDs Ip W, MIN [0.4 ap SDS Ip (1+2Z/h)/Rp W, 1.6 SDS Ip W] } = 1.3 MAX {0.3W, MIN[ 0.48 W, 1.6W]} 0.62 W, (SD) = 0.45 W, (ASD) 28.5 lbs Wind governs where SDS = 1.00 Ip = 1.00 ap = 1.00 Rp = 2.5 KH = 1.3 Page: 4 CI -FY OF LAUI---_ BUILDING & SAFETY DnEPTT APPROVE® FOR CONSTRUCTION DATE ---_BY I Anchorage of Appurtenances (Wind) Fh = 143.6 lbs (Wind) F„ = 14.7 lbs WD= 64.0 lbs d = 3.0 ft Analyze Tension T = Ft,/4 + ((WD+Fv) x Ecc / 2 x d) = 36 lbs Analyze Shear V = (WD+Fv) / 4 = 20 lbs Use (2) 1/2" A307 U -Bolts to secure each mounting bracket to new pipe mast T allowable > 36 lbs (small) OK V allowable > 20 lbs (small) OK USE: Mounting U -Clamp by MGF or 1/2"s U -Bolt to secure antenna. Project: T -MOBILE IE04478A Page: 5 b T d C CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATE BY I Ll F V W D� V Use (2) 1/2" A307 U -Bolts to secure each mounting bracket to new pipe mast T allowable > 36 lbs (small) OK V allowable > 20 lbs (small) OK USE: Mounting U -Clamp by MGF or 1/2"s U -Bolt to secure antenna. Project: T -MOBILE IE04478A Page: 5 b T d C CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATE BY I Project: T -MOBILE IE04478A Page: 6 Antenna Mounting Pipe F= 143.6 lbs WD= 64.0 lbs h, = 6.5 ft h2 = 2.0 ft M = 0.93 k' S req'd = 0.23 in < 1.72 in OK CHECK (N) 2 - 5/8" HILTI BOLTS T== F (h, + h2) / h2 = 610 lbs h, T h2 C b USE: 3"o STD pipe w/ (2) 1/2"o Lag Bolts (KB -TZ) w/ min. 3" pen. into new Blk'g. a CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE ----.BY Project_: T -MOBILE IE04478A Page: 7 Proposed RRU RRU Specifications - h=19.7in W=[::]in in d = Af = 2.33 7 ft` Av = 0.85 ft2 (Wind) Fh = 73.6 lbs (Wind ) F„ = 21.2 lbs Gravity Specifications W h Wind Governs Weight51.0 lbs d = 1;2 in (mounting hole distance) RRU Eccentricity = 1.0 ft Mounting Brackets Weight = 10.0 lbs Gravity Load W,,=F--6-1-0--1 I b s Seismic Desiqn Fseismic =. (KH) MAX { 0.3 SDS IP W, MIN [0.4 aP SDS IP 0+2z/h)/RP W, 1.6 SDS IP W] } = 1.3 MAX{ 0.3 W, MIN[ 0.48 W, 1.6 W]} 0.62 W, (SD) = 0.45 W, (ASD) 27.2 lbs CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE®. FOR CONSTRUCTION DATE BY Project: T -MOBILE . IE04478A • Page: 8 Anchorage of Appurtenances (Wind) Fh = 73.6 lbs (Wind) F„ = 21.2 lbs 3 b T WD= 61.0 lbs F d = 1.0 ft d C r Analyze Tension WD T = Fh/4 + ((Wo+Fv) x Ecc,/ 2 x d) = 18 lbs V Analyze Shear V = (Wp+Fv) A = 21 lbs Analyze Anchorage OK T allowable > 18 lbs (small) OK V allowable > 21 lbs (small) USE: RRU metal bracket W/ 5/8"o U -Bolt @ T & B to secure each RRU. CUY OF LA QUINTA BUILDING & SAFETY DEpT APPROVE® FOR CONSTRUCTION DATE ----_BY