BOTH2015-000978-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BOTH2O15-0009 Owner: .
Property Address: 78150 CALLE TAMPICO DUNCAN SMITH
APN: 770020024 17 ARDENDALE CT
Application Description: PLAZA TAMPICO CELL MODIFICATION ALAMO, CA 92253
Property Zoning:
Application Valuation: $15,000.00 r„� r-.
111111 Illil IIII IIII
,9
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/19/2016
Applicant: L -1I - Contractor:
SMARTLINK LLC N q THE W CORPORATION DBA VANTAGE COMPANY
18401 VOIN KARMAN AVE STE 400. FEB 19 2016 1643 W ORANGE GROVE AVE
IRVINE, CA 92612 CITYOFi4�l`I�._._,ORANGE, CA 92868
CCillit�°.TrOE+ELt�°:'E L�i'jvT (714)532-8800
Llc. No.: 799597
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. A License No.: 799597
Spate:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the f
basis for the alleged'exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his *or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
(__) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's N
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
1 I have and will maintain workers' compensation insurance, as required by
Se0n 3700 of the Labor Code, for the performance of the work for which this permit
is issued.{vly,workers' compensation insurance carrier policy number are:
Carrier S Policy Number:_
]-certify that in the performance of the work for which this permit is issued, I
s _ ]-c _.
shalFnot'employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
%! 7 'Y
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT'
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application. '
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and
shall.defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon
the -
above -mentioned property for inspection purposes.s
Dates Signature;(Appliean"t or Ag
DESCRIPTION :.
FINANCIAL INFORMATION
ACCOUNT.:'
QTY "AMOUNT
PAID
PAID DATE
ANTENNA, DISH
101-0000-42404
0 $108.78
$108.78
2/19/16
PAID BY
METHOD
RECEIPT #
CHECK # .
CLTD BY
THEODORE F HALSEY
DEBIT
MR267
RSE
DESCRIPTION,
ACCOUNT
QTY
'AMOUNT' '
PAID
PAID DATE
ANTENNA, DISH PC
101-0000-42600
0
$400.29
$400.29
2/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY., :
THEODORE F HALSEY
DEBIT
MR267
RSE
Total Paid for ANTENNA: $509.07 $509.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
2/19/16
PAID BY
METHOD
RECEIPT #,
CHECK #
CLTD BY
THEODORE F HALSEY
DEBIT
MR267
RSE
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
.:A000UNT .
QTY.
AMOUNT:
PAID .
PAID DATE
STORAGE RACKS, FIRST 100 LF
101-0000-42404
0
$24.66
$24.66
2/19/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
THEODORE F HALSEY
DEBIT
MR267
RSE
DESCRIPTION
ACCOUNT
QTY
AMOUNT '`
PAID
,PAID -DATE
STORAGE RACKS, FIRST 100 LF PC
101-0000-42600
0
$95.72
$95.72
2/19/16
PAID BY
METHOD
RECEIPT #
CHECK # .
CLTD BY
THEODORE F HALSEY
DEBIT
MR267
RSE
Total Paid for STORAGE RACKS: $120.38 $120.38
TOTALS: $630.45 $630.45
Description: PLAZA TAMPICO CELL MODIFICATION
Type: STRUCTURE OTHER THAN Subtype: Status: APPROVED -CONDITIONS
Applied: 12/15/2015 MFA
BUILDING
Approved:
Parcel No: 770020024 Site Address: 78150 CALLE TAMPICO LA QUINTA,CA 92253
Subdivision: PM 27109 Block: Lot: 1
Issued:
Lot Sq Ft:.O Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $15,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
2/8/2016
Details: MODIFICATION OF EXISTING WIRELESS TELECOMMUNICATIONS FACILITY TO ADD 3 ADDITIONAL ANTENNAS (1 PER SECTOR).
MINOR USE PERMIT APPROVAL REQUIRED, SEE MUP2015-0012 FOR APPROVAL FROM PLANNING
MUP2015-0012 APPROVAL LETTER RECEIVED.
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES .
LETTER
BURT HANADA
2/8/2016
2/8/2016
MUP2015-0012 APPROVAL LETTER RECEIVED FROM W.
NESBIT.
NOTE
AJ ORTEGA
1/6/2016
1/6/2016
MINOR USE PERMIT APPROVAL REQUIRED, SEE MUP2015-
0012 FOR APPROVAL FROM PLANNING PRIOR TO ISSUANCE.'
NOTE
MARY FASANO
12/15/2015
12/15/2015
PLANNING NEEDS TO APPROVE THE MINOR USE PERMIT
MUP2015-0012 BEFORE ISSUING THIS PERMIT
PLAN CHECK COMMENTS
FROM CONSULTANT
STEPHANIE GUMPERT
12/29/2015
12/29/2015
RECEIVED
TELEPHONE CALL
JIM JOHNSON
12/30/2015
12/30/2015
CALLED LUIS CARDONA TO INFORM HIM PLANS ARE READY
TO ISSUE.
CONDITIONS
Printed: Friday, February 19, 2016 8:42:35 AM 1 of 3 i
SYSTEMS
Printed: Friday, February 19, 2016 8:42:35 AM 2 of 3 r
sys•rcMs
FINANCIAL
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
SMARTLINK LLC
18401 VOIN KARMAN
AVE STE 400
IRVINE
CA
92612
JMCCOMMELL@SMAR
TLINKLLC.COM
CONTRACTOR
THEW CORPORATION DBA VANTAGE
COMPANY
1643 W ORANGE
GROVE AVE
ORANGE
CA
92868
DEBIT
THEODORE F HALSEY
RSE-
SE-ANTENNA,
OWNER
DUNCAN SMITH
17 ARDENDALE CT
ALAMO
CA
92253
DEBIT
THEODORE F HALSEY
RSE
Printed: Friday, February 19, 2016 8:42:35 AM 2 of 3 r
sys•rcMs
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT CITY
AMOUNT
PAID
PAID DATE
RECEIPT # CHECK #
METHOD
PAID BY
CLTD
BY
ANTENNA, DISH
101-0000-42404 0
$108.78
$108.78
2/19/16
MR267
DEBIT
THEODORE F HALSEY
RSE-
SE-ANTENNA,
ANTENNA,DISH PC
101-0000-42600 0
$400.29
$400.29
2/19/16
MR267
DEBIT
THEODORE F HALSEY
RSE
Total Paid for ANTENNA:
$509.07
$509.07
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
2/19/16
MR267
DEBIT
THEODORE F HALSEY
RSE
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00
$1.00
BSA:
STORAGE RACKS, FIRST
101-0000-42404
0
$24.66
$24.66
2/19/16
MR267'
DEBIT
THEODORE F HALSEY
RSE
100 LF
STORAGE RACKS, FIRST
101-0000-42600
0
$95.72
$95.72
2/19/16
MR267
DEBIT
THEODORE F HALSEY
RSE
100 LF PC
Total Paid for STORAGE RACKS:
$120.38
$120.38
TOTALS:
Printed: Friday, February 19, 2016 8:42:35 AM 2 of 3 r
sys•rcMs
IST BLDG NS (2 WK)
JIM JOHNSON
1 12/15/2015
12/31/2015
1 12/30/2015
1 APPROVED
1ST BLDG STR (2
.WK)
KURT CULVER
12/15/2015
12/31/2015
12/24/2015
READY FOR APPROVAL
ETRAKIT ENABLED
RnND INFORMATInN
Printed: Friday, February 19, 2016 8:42:35 AM 3 of 3
SYSTEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
IST REVIEW
BOTH2O15-0009 - 1ST
DOC
12/28/2015
AJ ORTEGA
STRUCTURAL FEE SHEET
REVIEW STRUCTURAL
0
(ESGIL)
FEE SHEET.pdf
1ST REVIEW
BOTH2OIS-0009 - 1ST
DOC
12/28/2015.
AJ ORTEGA
STRUCTURAL
REVIEW STRUCTURAL
1
TRANSMITTAL
TRANSMITTAL.pdf
DOC
2/8/2016
BURT HANADA
MUP2015-
MUP2015-
1
0012_Approvalltr.pdf
0012_Approvalltr.pdf
Printed: Friday, February 19, 2016 8:42:35 AM 3 of 3
SYSTEMS
sin. L.
Cltj/ Of- U. QuIon: to
BulWirig er Safety Division '
P.O. Box 1504,78-495 Calle Tampico
CO ia.Quinta, CA 92253.:(760) 777-7012
Building Permit -Application and Tracking Sheet
Permit #
Project Addtcss: 78150 Calle Tampico
Owner's Name:.Smith Family Trust
A P. Number. 7.70-020-024.
Address: 17 Ardendale Court
Legal Description:
City, ST, Zip: Alamo, CA 94.507
Contractor. TBD
Telephone: N/A
Project Description: Modification of existing wireless
Address:
City, ST, Zip:
telecommunications facility to add 3 additional antennas .
Telephone:
State Lic. #: (Sty Lic. t.
(1 per sector)
Arch., Engr., Designer. Breen Engineering
Address: 6281 Beach'Blvd. #125
City., ST, Zip: Buena Park, CA 90621
Telephone: 657-529-2'111 Construction Type:. Occupancy:
State Lic. #: 54194 Project type (circle one): New Add'n Altar Repair Demo
Name of Contact Person: Luis Cardona Sq. Ft.: # stories: # Unitp:
Telephone # of Contact Person: 657-529-2111 Estimated Value of Project
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
R 'd
Recd
TBACMG
PERMY FEES
Pisa Sets
Plan Check submitted
item Amount
Stroctur'al Calfa
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Calco.
Called Contact Person
Plan Check Balance -
Tithe 24 Calci.
Plans picked up
Construction
Flood plain pian
Plans resubmitted .' .
Mechanical
Giading plan
2id Review, ready for correctionsrissue
Electrical
Subeontaetor List
Called Contact Person
Plumbing
. Grant Deed
Plans picked up
S.M.1.
H.O.A. Approval
Plans resubmitted
Grading
!iY HOUSE,,
'"` Review; ready for carrectionsJissue
Developer Impact Fee
Planning Approval.
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue
school Fees
Total Permit Fees
,c
EsGil Corporation
In Partnership with Government for Building Safety
DATE: 12/24/2015 ❑ APPLICANT
,& JURIS.
JURISDICTION: City of La Quinta ❑ PLAN REVIEWER
❑ FILE
PLAN CHECK NO.: BOTH2O15-0009 SET: I
PROJECT ADDRESS: 78150 Calle Tampico
PROJECT NAME: T -Mobile CM478 Plaza Tampico IE04478A
® The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted fora complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil Corporation staff did not advise the applicant that the plan check has been completed.
❑ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:.
Date contacted: (by: ) Email: RECEIVED
Mail Telephone Fax In Person DEC 2 9 2015
® REMARKS: structural review only
CITY OF OEVELOPMEIdT
QUINTA
By: David Yao Enclosures: COMMUNE
EsGil Corporation
❑ GA ❑ EJ ❑ MB ❑ PC 12/17
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858)560-1468 ♦ Fax(858)560-1576
City of La Quinta BOTH2O15-0009
12/24/2015
ADO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of La Quinta PLAN CHECK NO.: BOTH2O15-0009
PREPARED BY: David Yao DATE: 12/24/2015
BUILDING ADDRESS: 78150 Calle Tampico
BUILDING OCCUPANCY: B
BUILDING
PORTION
AREA
( Sq. Ft.)
Valuation Reg. VALUE ($)
Multiplier Mod.
cell site revision
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
Ilq IManual input
Bldg. Permit Fee by Ordinance I I
Plan Check Fee by Ordinance -W
Type of Review: ❑ Complete Review
❑ Repetitive Fee
Repeats
* Based on hourly rate
❑ Other
a—H_ourly
EsGil Fee
E] Structural Only
2 Hrs. @
$87.15
$217.88
$174.30
Comments:
Sheet 1 of 1
macvalue.doc +
e�FiC�
B R E E N
k-7iz, Engineering Inc
T -MOBILE
IE04478A
CM478 PLAZA TAMPICO
78150 Calle Tampico
La Quinta, CA 92253
Prepared for
Smartlink
STRUCTURAL CALCULATIONS
Equipment Support
September 24, 2015
CITY OF LA QUIN
i BUILDING & SAFETY DE
{ APPROVED
FON CONS UCTION
i
s
1983 W 190th Street, Suite 200 I Torrance, CA 90504
T 310.464.8404 I F: 310.464.8408 I www.breeneng.com
orF►(e ctPy
a
ie>r�s:Tiief eesreersae�e�a
i •,
�8 -(s0 co Tirtwo
trt • �n�trt
u' .cis np ".3
.1j;..
1EIVE®
DEC 152015
C17Y OF LA QUINTA
COMMUNITY DEVELOPMENT fl
Project: T -MOBILE
IE04478A
Page: 1
Design Criteria
I. Code
California Building Code, 2013 Edition.
ASCE7-10 Minimum Design Loads for Buildings & other structures
II. Scope of Work
1. Provide structural review of the proposed addition of (1) antenna mounted on the
pipe support in sectors A, B and C.
2. Provide structural review of the proposed addition of (1) RRU unit mounted on the
pipe support in sector A, B and C.
III. Citation
The following documents were provided to Breen for the purpose of generating this
report. It is assumed that this information is accurate and correct. Breen shall not be
responsible for information/calculations prepared by others or for errors in our
design as a result of inaccurate information provided to us.
1. Construction drawings provided by SBA Consulting, Inc. dated 10/04/96.
2. Construction drawings provided by Reliant Land Services dated 01/16/13.
IV. Summary
STRUCTURAL -PASS
Provisions of Analysis & Disclaimer:,
The analysis and conclusions contained in this report are based on information provided by T -Mobile.
Construction not performed in accordance with the provisions contained herein will void this report.
Breen declines any responsibility for damages that originated prior to the proposed
modifications/additions or for the accuracy of design/calculations done by other-s-o._or variations in
the design and field conditions. Discrepancies between field conditions and this."epa t qtr ul b� Q�� T
immediately brought to the attention of Breen for review. vIN
BUILDING & SAFETY DEPT.
FOR R CONSTRUCTION
DATE -_BY
Project: T -MOBILE
IE04478A
Page: 2
4
Proposed Antenna: COMMSCOPE LNX-6513DS-VTM
W
Antenna Specifications >
H=54.9 in
W= 11.9 in
D = 7.1' in H D
Af = 4.5 ft`
Ar = 0.6 ft`
Gravity Specifications
Weight = 26.0 lbs
d= 36 in
Antenna Eccentricity = 1.5 ft
Mounting Brackets
Weight = 20.0 lbs
Mounting pipes
Weight =lil
lbs
H= in
Diameter =in
Gravity Load Wp= 64.0 Ibs
CI OF L C�UINTq
' BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA,TE�_ BY
Wind Design
Design Code: California Building Code, 2013 Edition, Chapter 16
ASCE 7-10
Exposure "C"
Basic Wind speed = 110.0 mph
Height of structure = 42 ft
Risk Category II
VELOCITY PRESSURE
qZ = 0.00256 KZ KZt Kd VZ ASCE 7-10 (29.3-1)
psf
qz (MIN.) = 16.0 psf
WIND LOAD
Fh = qh (GCr) Af ASCE 7-10 (29.5-2)
52.7 psf
31.6 psf (ASD)
F„ = qh (GCr) A, ASCE 7-10 (29.5-3)
41.6 - psf
25.0 psf (ASD)
where
KZ =2.01 ( Z / Z9 )2/° = 1.05
KZt =
1.0
Kd =
0.85
V =
110.0
GCr =
1.9
for latheral force
GCr =.I
1.5
for vertical uplift
Project: T -MOBILE
IE04478A
Page: 3
CITY OF------
BUILDING &L q QU(NTA
Y DEPT
APPROVED
FOR CONSTRUCTION
DATE -_BY _
Project: T -MOBILE
IE04478A
Seismic Design
Fseismic = (KH) MAX (0.3 SDs Ip W, MIN [0.4 ap SDS Ip (1+2Z/h)/Rp W, 1.6 SDS Ip W] }
= 1.3 MAX {0.3W, MIN[ 0.48 W, 1.6W]}
0.62 W, (SD)
= 0.45 W, (ASD)
28.5 lbs Wind governs
where SDS =
1.00
Ip =
1.00
ap =
1.00
Rp =
2.5
KH =
1.3
Page: 4
CI -FY OF LAUI---_
BUILDING & SAFETY DnEPTT
APPROVE®
FOR CONSTRUCTION
DATE
---_BY I
Anchorage of Appurtenances
(Wind) Fh =
143.6
lbs
(Wind) F„ =
14.7
lbs
WD=
64.0
lbs
d =
3.0
ft
Analyze Tension
T = Ft,/4 + ((WD+Fv) x Ecc / 2 x d) = 36 lbs
Analyze Shear
V = (WD+Fv) / 4 = 20 lbs
Use (2) 1/2" A307 U -Bolts to secure each mounting bracket to new pipe mast
T allowable > 36 lbs (small) OK
V allowable > 20 lbs (small) OK
USE:
Mounting U -Clamp by MGF or 1/2"s U -Bolt to secure antenna.
Project: T -MOBILE
IE04478A
Page: 5
b T
d
C
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVE®
FOR CONSTRUCTION
DATE BY I
Ll
F
V
W D�
V
Use (2) 1/2" A307 U -Bolts to secure each mounting bracket to new pipe mast
T allowable > 36 lbs (small) OK
V allowable > 20 lbs (small) OK
USE:
Mounting U -Clamp by MGF or 1/2"s U -Bolt to secure antenna.
Project: T -MOBILE
IE04478A
Page: 5
b T
d
C
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVE®
FOR CONSTRUCTION
DATE BY I
Project: T -MOBILE
IE04478A
Page: 6
Antenna Mounting Pipe
F= 143.6 lbs
WD= 64.0 lbs
h, = 6.5 ft
h2 = 2.0 ft
M = 0.93 k'
S req'd = 0.23 in < 1.72 in OK
CHECK (N) 2 - 5/8" HILTI BOLTS
T== F (h, + h2) / h2 = 610 lbs
h,
T
h2
C b
USE:
3"o STD pipe w/ (2) 1/2"o Lag Bolts (KB -TZ) w/ min. 3" pen. into new
Blk'g.
a
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE ----.BY
Project_: T -MOBILE
IE04478A
Page: 7
Proposed RRU
RRU Specifications -
h=19.7in
W=[::]in
in
d =
Af = 2.33 7 ft`
Av = 0.85 ft2
(Wind) Fh = 73.6 lbs
(Wind ) F„ = 21.2 lbs
Gravity Specifications
W
h
Wind Governs
Weight51.0 lbs
d = 1;2 in (mounting hole distance)
RRU Eccentricity = 1.0 ft
Mounting Brackets
Weight = 10.0 lbs
Gravity Load W,,=F--6-1-0--1 I b s
Seismic Desiqn
Fseismic =. (KH) MAX { 0.3 SDS IP W, MIN [0.4 aP SDS IP 0+2z/h)/RP W, 1.6 SDS IP W] }
= 1.3 MAX{ 0.3 W, MIN[ 0.48 W, 1.6 W]}
0.62 W, (SD)
= 0.45 W, (ASD)
27.2 lbs
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVE®.
FOR CONSTRUCTION
DATE BY
Project: T -MOBILE .
IE04478A
• Page: 8
Anchorage of Appurtenances
(Wind) Fh = 73.6 lbs
(Wind) F„ = 21.2 lbs 3 b T
WD= 61.0 lbs F
d = 1.0 ft d
C
r
Analyze Tension
WD
T = Fh/4 + ((Wo+Fv) x Ecc,/ 2 x d) = 18 lbs V
Analyze Shear
V = (Wp+Fv) A = 21 lbs
Analyze Anchorage
OK
T allowable > 18 lbs (small)
OK
V allowable > 21 lbs (small)
USE:
RRU metal bracket W/ 5/8"o U -Bolt @ T & B to secure each RRU.
CUY OF LA QUINTA
BUILDING & SAFETY DEpT
APPROVE®
FOR CONSTRUCTION
DATE ----_BY