BSOL2015-024678-495 CALLE TAM PICO U
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BSOL201S-0246
Property Address: 79555 N TOM FAZIO LN
APN: 766032016 '
Application Description: KHOSHIYATI/5.6kW PV SYSTEM - (18) 31OW PANELS/(1) INVERTER
Property Zoning:
Application Valuation: $15,000.00
Applicant: CTSUPY
C K- ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: CSO License No.: 354550
Date: ,��5-Z6/C Contractor. -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work,
himself or herself through his or her own.employees, provided that the improvements
are not intended or offered for sale. If, however; the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(� I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
11111111111111111111
31
VOICE (760).777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 1/15/2016
Owner:
NADER & SHIRLEY•KHOSHNIYATI
19 LAGUNA DR
LAGUNA BEACH, -CA -92
7
Contractor:
I) JAN
C K ELECTRIC rtNr1FI l 01)1h'
1204 LOS BAUTI�N(��^Sb\I N�EVELOPInENTDI.Fr^ •'•'
SAN CLEMENTE, CA92 �4-1�_--_
(949)218-5434
Llc. No.: 354550
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and polity number are:
Carrier: _ Policy Number: '
I certify that in the performance of the work for•which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Q.r
ate:. 4/5- -20 / ,; Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
'APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance'of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of .
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county'ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes. I -
Date: =L�/J� ZOZe Signature (Applicant or Agent)
FINANCIAL '
' •
DESCRIPTION '
ACCOUNT
QTY AMOUNT PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0 $1.00 $1.00
1/15/16
PAID BY
METHOD
RECEIPT # CHECK #
CLTD BY
DONN D REESE
DEBIT
MR252 064416
TSA
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$24.17
1/15/16
PAID BY '
METHOD
RECEIPT #
CHECK #
CLTD BY
DONN D REESE
DEBIT
MR252
064416
TSA
DESCRIPTION "
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$24.17
1/15/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DONN D REESE
DEBIT
MR252
064416
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT
101-0000-42403
0
$24.17
$24.17
1/15/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DONN D REESE
DEBIT
MR252
064416
TSA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
- PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT PC
101-0000-42600
0
$24.17
$24.17
1/15/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DONN D REESE
DEBIT.
MR252.
064416
TSA
Total Paid for ELECTRICAL: $96.68 $96.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
1/15/16
PAID BY
METHOD.
RECEIPT #
CHECK #
CLTD BY
DONN D REESE
DEBIT
MR252
064416
TSA
Total Paid for PERMIT ISSUANCE: $91.85 $91.85
TOTALS:
Description: KHOSHIYATI/5.6kW PV SYSTEM - (18) 31OW PANELS/(1) INVERTER
Type: SOLAR Subtype: Status: APPROVED
Applied: 12/22/2015 MFA
Approved:
Parcel No: 766032016 Site Address: 79555 N TOM FAZIO LN LA QUINTA,CA 92253
Subdivision: TR 27728 Block: Lot: 45
Issued:
Lot Scl Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $15,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
PLAN CHECK -SUBMITTAL
Details: 5.6kW SOLAR ARRAY - (18) 255W SOLARWORLD SW XL 315M+SOLAREDGE P400 OPTIMIZERS W/ (1) SOLAREDGE SE6000A-US-ZB-U-
AFCI INVERTER [270SF] 2013 CALIFORNIA ELECTRICAL CODE.
Printed: Friday, January 15, 2016 1:52:35 PM 1 of 3
-• #?w-1YS TEMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
PLAN CHECK -SUBMITTAL
MARY FASANO
12/22/2015
12/22/2015
PER BURT, THIS PLAN CHECK CAN BE REVIEWED IN HOUSE
.RECEIVED
AND NOT SENT TO ESGIL
CUSTOMER CAME IN WITH REVISED SET OF PLANS. OVER THE
COUNTER PLAN CHECK. APPROVED. BSOL2015-0009 IS ALSO
PUBLIC COUNTER VISIT
LUIS URIBE
1/15/2016
1/15/2016
ON THIS ADDRESS WITH OUTSTANDING PLAN CHECK FEES.
FEE WILL BE PAID ON BSOL2015-0009 BEFORE WE ISSUE THIS
PERMIT. CONTRACTOR STATED THAT IS FINE.
SPOKE WITH DONN REESE, 1ST REVIEW IS COMPLETE PLANS
TELEPHONE CALL
LUIS URIBE
12/29/2015
12/29/2015
ARE READY FOR CORRECTIONS. DONN ASKED IF I CAN EMAIL
A COPY OF THE CORRECTIONS LIST -1 TOLD HIM NOT A
PROBLEM. CORRECTIONS LIST WAS SENT VIA EMAIL.
CONDITIONS
Printed: Friday, January 15, 2016 1:52:35 PM 1 of 3
-• #?w-1YS TEMS
INSPECTIONS
PARENT
PROJECTS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
C K ELECTRIC
1204 LOS BAUTISMOS
SAN CLEMENTE
CA
92672
LANE
CONTRACTOR
C K ELECTRIC
1204 LOS BAUTISMOS
SAN CLEMENTE
CA
92672
LANE
OWNER
NADER & SHIRLEY KHOSHNIYATI
19 LAGUNA DR
LAGUNA BEACH
CA
92651
FINANCIAL
INFORMATION
CLTD
DESCRIPTION
ACCOUNT
QTY
....AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
BSAS SB1473 FEE
101-0000-20306
0.
$1.00
$1.00
1/15/16
MR252
064416
DEBIT
DONN D REESE
TSA
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00
$1.00
BSA:
PV SYSTEM - ARRAY,
101-0000-42403
0
$24.17
$24.17
1/15/16
MR252
064416
DEBIT
DONN D REESE
TSA
FIRST 20
PV SYSTEM -ARRAY,
101-0000-42600
0
$24.17
$24.17
1/15/16
MR252
064416
DEBIT
DONN D REESE .
TSA
FIRST 26 PC
PV SYSTEM -MISC
101-0000-42403
0
$24.17
$24.17
1/15/16
MR252
064416
DEBIT
DONN D REESE
TSA
EQUIPMENT
PV SYSTEM -MISC
101-0000-42600
0
$24.17'
$24.17
1/15/16
MR252
064416
DEBIT
DONN D REESE
TSA
EQUIPMENT PC
Total Paid for ELECTRICAL:
$96.68
$96.68
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
1/15/16
MR252
064416
DEBIT
DONN D REESE
TSA
Total Paid for PERMIT ISSUANCE:
$91.85
$91.85
TOTALS:
INSPECTIONS
PARENT
PROJECTS
Printed: Friday, January 15, 2016 1:52:35 PM 2 of 3 CJ?�
SYSTEMS
REVIEW TYPE REVIEWER
SENT DATE
DUE DATE
RETURNED STATUS REMARKS NOTES
DATE,
1ST BLDG NS (1 WK) LUIS URIBE
12/22/2015
1/4/2016
12/29/2015 REVISIONS REQUIRED
2ND BLDG NS (1
LUIS URIBE
WK) .
1/15/2016
1/15/2016
1/15/2016 APPROVED
Printed: Friday, January 15, 2016 1:52:35 PM 3 of 3
�J CFEY SYSTIMS
PLACARD
SOLAR PV ARRAY
WITH OPTIMIZERS
ROOF MOUNTED
f 4
i
CAUTION
POWER TO THE BUILDING IS ALSO SUPPLIED FROM
THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AT SHOWN
i <N
� �S
SERVICE POINT UTILITY METERING
SCONNECT
5
N
S
APPROVAL STAMP AND ADDITIONAL NOTES FOR THE CITY OF: LA QUINTA
SHEET INDEX
SYSTEM OVERVIEW
• ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING,
PROJECT NOTES: COVER
5.67 KW SYSTEM
RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN
PLOT PLAN & PHOTOVOLTAIC LAYOUT : PV -I
ATTACHMENT LAYOUT &CALCULATIONS: PV -2,i
ATTACHMENT DETAILS: PV -2.1
(18) SoLARWoRLD SW XL 315 '�,N
(18) SoLAREDGE P400 -
BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE.
• PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE
FIRE SIGNS/LABELS: PV -3
MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING,
SINGLE LINE DIAGRAM: PV -4
SOLAREDGE SE6000A-US
MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF
MANUFACTURE SPEC. SHEETS: ATTACHED
GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN
AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC §690.4(B))
• PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND
GENERAL NOTES
• CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT
INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC
CUSTOMER INFORMATION
§690.4(E))
PERINEC 310.0(D)
NADER KHOSHNIYATI
• CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET
LOCATIONS PER NEC 310.8(C)
• WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT
77-555 TOM FAZIO LANE
WILL BE MAINTAINED IN ACCORDANCE WITH THE NEC 110.26
LA QUINTA, CA 92253
• EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE.
• SMOKE ALARMS AND CO2 ALARMS TO BE INSTALLED
• STRUCTURAL MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED
PARCEL #: 766032023
AND VERIFIED AS NECESSARY FOR LAG BOLT.PENETRATIONS BY CONTRACTOR.
• SEAL CONNECTION POINTS WITH ROOF GRADE
CONTRACTOR INFORMATION
• ROOF PENETRATIONS ARE SEALED WITH SCHNEE MOREHEAD 7108 SEALANT.
CK ELECTRIC 46
• PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY
WIRING TO CONDUIT WIRING.
• PROVIDE GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN
1204 LOS BAUTISMOS LANE
SERVICE GROUND ELECTRODE PER C.E.C. ARTICLE 250.50 THROUGH 250.86.
SAN CLEMENTE, CA 92672
• GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE
TO BE MINIMUM PROTECTION OF BARE ARMOR SHEATHED CABLE FOR ALL
(949) 748-0701
CONDUCTOR SIZES. Q
• ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE n
PANEL. IJ
ENT FARMER
I O
• INVERTER IS LISTED TO UL -1741 "UTILITY INTERACTIVE"
• ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. [JAN 15
`
�^ I C+10 # . 55
2010 6!�,JJJ
• ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2.Vi+�+rX
• MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2% CON^ UNITYDEVELOK,
hi DEFr'..-LLEjiJT
• ALL CONDUCTORS SHALL BE CONDUIT UNLESS OTHERWISE NOTED.-`"`"
CITY OF LA QUINTA
BUILDING & SAFETY DEPT
DEP�t
VICINITY MAP
PPROVED
FOR CONSTRUCTION
ATE
�,r----=-----�._............
REV.
DESCRIPTION
A
1
-11641, 1B
4
C
r
D
DATE: 1/4/16
SOV
J
Awl .� _
C0 VE
DRAFTER: CNG2
N
'lel
C
\0 ��
o
PLOT PLAN & INSTALL LOCATION
SCALE: I' = 30'
PV
(18) SOLARWORLD SW XL 315M
OP
(18) SOLAREDGE P400
MICRO
MSP
(E) 400A MSP W/ 400A MAIN BREAKER
MSP -D
MSP -U
PM
AC
60A KNIFE -BLADE AC DISCONNECT
T
SP 200A SUB -PANEL
INV -1 SOLAREDGE SE6000A-US
INV -2
INV -3
JB JUNCTION BOX
PROPOSED PV CONDUIT RUN ABOVE ROOF
J i — PROPOSED PV CONDUIT RUN THROUGH ATTIC
-- PROPERTY LINES
Q PV SOLAR MODULES - FLUSH MOUNTED
® ® VENTS & OBSTRUCTIONS ® CHIMNEY
® ROOF ACCESS POINT: ROOF ACCESS POINT SHALL BE LOCATED
IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS
OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG
POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS
POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS
TREE LIMBS, WIRES OR SIGNS.(R331.4.1 OF THE 2013 CRC)
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAZIO LANE
LA QUINTA, CA 92253
PARCEL #:766032023
CONTRACTOR INFORMATION
CK ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIO #35 50
X
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVE®
FOR CONSTRUCTION
DATE _ BY
REV. DESCRIPTION DATE
A
B
C
D
DATE: 1/4/16 PLOT PLAN
DRAFTER: CNG2 P V — I
SOLAR PANEL ARMY
SYMBOL LEGEND
MA%NNM VOLTAGE: 680V
SVSTEN CALCULATION:
SOLAR PANEL ARRAY
W9- GAS -:GAS-
DPf CLRMUM IUOT VOLTAGE: 39.N
M0.UMUM POWER CURRENT: 36SV
(„�,%E P.I1FD Mml % 13Y • BPi M
(9) 3IS%Y PROSERISE %L
(91 SOLAR EDGE OC
SHORT GRWIT CURREM: B.9}A
25p MODULE X 1.25 = 31.25A [USE 40A DBL BRKj
MODULES BY SOLAR WORLD
}�%
01`MTINOCURRENT: _6A
G
(9) SOLAR EDGE DC
SE E000AAIS }WA SUB AC DISCONNECT
INVERTER P_EL
Y�' EMT CONWIT
x PANEL
%DDA SERVILE
OPRMMERS 1`3W
I j
(a) Q TH_N3
(f) e8 THHN Gf W
I•
3. JUNCTION BOX PROVIDES TRANSITION FROM
I
UL USTEDUS
YA'EMTCONOUR Y"EMTCONOUIT
4. PROVIDE CONTINUOUS GROUND TO MAIN
F%MMP
ELECTRICAL PANEL. C.E.0 2010 250.5.250.86
ES CABLES
(�)p10 THNN.2 M.", TNWN-}
I
®•• ROOFING MATERIAL
CONCRETE TILE
SHEETED CABLE FOR ALL CONDUCTOR SIZES.
(1)N1 MHN•GRN (1)ae MNN GRN
DISCONNECT
4. INSTALLATION OF (1) 6.0 KW INVERTER
wDw
SERVICE GROUND IN MAIN SERVICE PANEL.
SOLAR PANEL ARMY
SYMBOL LEGEND
® PHOTOVOLTAIC MODULE
(9) 31RY PROSERISE XL
- Gn5 ',IGAS-
W9- GAS -:GAS-
lAODULE9 By 9DUR W
f
(91 SOLAR EDGE OC
II
8.9 app BRK fiOgMP
OP ITLI.ERS P-
CK ELECTRIC
_�.
1
I .
G
I I
SE E000AAIS }WA SUB AC DISCONNECT
INVERTER P_EL
PV ELECTRICAL LINE DIAGRAM NTS
-I !
I
I
I j
0
I•
I
_1. - .....
I
I
I
0
fP 7-7- - -....
I
li
I I
J
S/A' DR CO!®MT Y101t
(A) O is THN OR, C
i
1x}!'0}]}•f }e}.Ie1 q6u - _ _ SITE PLAN „B=,•o
SYMBOL LEGEND
® PHOTOVOLTAIC MODULE
- Gn5 ',IGAS-
W9- GAS -:GAS-
GAS- GAS- GAS='GAS
802 S. EL CAMINO REAL,
f
I I--------T-
II
-- - - - - --
-------------
CK ELECTRIC
_�.
1
I .
G
I I
400 AMP SERVICE
ROOF DATA
-I !
I
I
I j
;
SCOPE OF WORK
3. JUNCTION BOX PROVIDES TRANSITION FROM
I
ROOF SLOPE
4:12 SLOPE
4. PROVIDE CONTINUOUS GROUND TO MAIN
.I
I j..,...._...........
ELECTRICAL PANEL. C.E.0 2010 250.5.250.86
i�
- - _
I
®•• ROOFING MATERIAL
CONCRETE TILE
SHEETED CABLE FOR ALL CONDUCTOR SIZES.
F-
DISCONNECT
4. INSTALLATION OF (1) 6.0 KW INVERTER
L
SERVICE GROUND IN MAIN SERVICE PANEL.
7. INVERTER MODEL IS LISTED TO UL 1741
ROOF STRUCTURE
WOOD FRAMING
'
II
I. ARRAY, PROJECT INFORMATION, GENERAL
LOCKABLE. 240V AC. 30 AMP.
f
NOTES AND SINGLE LINE DIAGRAM
!
AND DC SIDE TO BE SIZED ACCORDING TO NEC
2. PV ARRAY MANUFACTURE DATA SHEETS
SECTION 690.
AND SINGLE LINE DIAGRAM
----� iREFERENCED
i�
3. PRO SOLAR'FAST JACK' INSTALLATION
11. ALL CONDUCTORS SHALL BE 6GOV, 90C
--.._ j
MANUAL
- GAS -
G4R - GAS - GAS ---
12. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5%
13. ALL CONDUCTORS SHALL BE IN CONDUIT
UJ I
UNLESS OTHERWISE NOTED - SEE ELECTRICAL
I
LINE DIAGRAM
iT
NATIONAL ELECTRICAL CODE. 2013 CALIFORNIA
�.
ELECTRICAL CODE AND THE 2013 CALIFORNIA
I
BUILDING CODE
15. EXACT CONDUIT RUN LOCATIONS SUBJECT TO
CHANGE
•'
16. A GROUND FAULT DETECTION INTERRUPTION
'
(GFDI) DEVICE IS INTEGRATED WITH THE
INVERTER IN ACCORDANCE WITH NECICEC
690.5
17. AC CONDUCTORS SHALL BE COLOR CODED AS
FOLLOWS: PHASE A -BLACK. PHASE BRED.
PHASE C -BLUE. NEUTRAL -WHITEIGREY
PANEL SO ARMY
min':
!
SOLAR ARRAY SHALL NOT EXCEED 3.0 PSF.
19. NOTIFY UTILITY PROVIDER PRIOR TO
4
_
118)
2) sTRW(GS OF (9) 315W
I PROSERIM XL PANELS BY
/
..I..•
I WORLD mm (13) SOLAR
EDGE OC OPTIMIZERS
1=-+�T•my�aw=nmt�-',
(+SOLAR
y'
!
_ .._...i.s• _("+._'_
'
.��
J -BOX
-j ---:-J C=,-
;
:
AWSe
I I
J
S/A' DR CO!®MT Y101t
(A) O is THN OR, C
i
1x}!'0}]}•f }e}.Ie1 q6u - _ _ SITE PLAN „B=,•o
- LNYERTER AND
SUB PANEL IN ,
UTILITY ROOM I 1
I I!••� I i�
\ E it
AODA MAIN
PANEL SERVICE \ E
60A A/C \ f
DISCONNECT
F
\IF
SYMBOL LEGEND
® PHOTOVOLTAIC MODULE
MODULE TO INVERTER
JOB SITE INFORMATION
CONNECTION
802 S. EL CAMINO REAL,
ADDRESS: 77.555 TOM FAZIO LN.
PH: (949) 748 - 0701
PITCH
CITY: LA OUINTA, CA 92253
NORTH NORTH ARROW
CK ELECTRIC
UTILITY PROVIDER: IMPERIAL IRRIGATION DIST.
204 BAUTISMOS LN.
MODULES BY SOLAR WORLD WITH (18) P900
400 AMP SERVICE
SOLAR EDGE DC OPTIMIZERS -SEE
-I !
SYSTEM SIZE 5.7 KW SYSTEM
I j
LINE DIAGRAM
SCOPE OF WORK
3. JUNCTION BOX PROVIDES TRANSITION FROM
iARRAY
1. INSTALLATION OF (18) PHOTOVOLTAIC
4. PROVIDE CONTINUOUS GROUND TO MAIN
SOLAR PANELS.
ELECTRICAL PANEL. C.E.0 2010 250.5.250.86
i�
2. INSTALLATION OF (18) DC OPTIMIZERS
I
cO
~
^^
LL
INVERTER TO BE MIN. PROTECTION OF ARMOR
3. INSTALLATION OF (1) 30A DIC
SHEETED CABLE FOR ALL CONDUCTOR SIZES.
F-
DISCONNECT
4. INSTALLATION OF (1) 6.0 KW INVERTER
L
SERVICE GROUND IN MAIN SERVICE PANEL.
7. INVERTER MODEL IS LISTED TO UL 1741
�i
SHEET INDEX
'
II
I. ARRAY, PROJECT INFORMATION, GENERAL
LOCKABLE. 240V AC. 30 AMP.
f
NOTES AND SINGLE LINE DIAGRAM
!
AND DC SIDE TO BE SIZED ACCORDING TO NEC
2. PV ARRAY MANUFACTURE DATA SHEETS
SECTION 690.
AND SINGLE LINE DIAGRAM
----� iREFERENCED
i�
3. PRO SOLAR'FAST JACK' INSTALLATION
11. ALL CONDUCTORS SHALL BE 6GOV, 90C
--.._ j
MANUAL
- GAS -
G4R - GAS - GAS ---
- LNYERTER AND
SUB PANEL IN ,
UTILITY ROOM I 1
I I!••� I i�
\ E it
AODA MAIN
PANEL SERVICE \ E
60A A/C \ f
DISCONNECT
F
\IF
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAzlo LANE
LA QUINTA, CA 92253
PARCEL #:766032023
CONTRACTOR INFORMATION
CK ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIO #3 550
X
CITY OF LA QUIiNTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY �_
REV. DESCRIPTION DATE
A
B
C
D
DATE: 1/4/16 SITE
PLAN
DRAFTER: CNG2 PV -.I' . I
SYMBOL LEGEND
® PHOTOVOLTAIC MODULE
MODULE TO INVERTER
CONNECTION
802 S. EL CAMINO REAL,
DIRECTION OF ROOF
PH: (949) 748 - 0701
PITCH
CONTRACTOR
NORTH NORTH ARROW
CK ELECTRIC
1. PV ARRAY CONTAINS 1181315W PROSERIES XL
204 BAUTISMOS LN.
MODULES BY SOLAR WORLD WITH (18) P900
SAN CLEMENTE, CA. 92672
SOLAR EDGE DC OPTIMIZERS -SEE
-I !
MANUFACTURE DATA ON SHEET 2
2. WIRING TO INVERTERS IS PER ELECTRICAL
I j
LINE DIAGRAM
Q0
3. JUNCTION BOX PROVIDES TRANSITION FROM
iARRAY
WIRING TO CONDUIT
4. PROVIDE CONTINUOUS GROUND TO MAIN
I i
ELECTRICAL PANEL. C.E.0 2010 250.5.250.86
i�
S. GROUND ELECTRODE CONDUCTOR FROM
I
cO
~
^^
LL
INVERTER TO BE MIN. PROTECTION OF ARMOR
ti
SHEETED CABLE FOR ALL CONDUCTOR SIZES.
F-
6. ALL GROUNDS SMALL BE CONNECTED TO MAIN
L
SERVICE GROUND IN MAIN SERVICE PANEL.
7. INVERTER MODEL IS LISTED TO UL 1741
-UTILITY INTERACTIVE'
O
8.AC DISCONNECTS SHALL BE VISIBLE OPEN,
J
LOCKABLE. 240V AC. 30 AMP.
i
9. EQUIPMENT GROUNDING CONDUCTORS ON AC
!
AND DC SIDE TO BE SIZED ACCORDING TO NEC
!
SECTION 690.
10. NEGATIVE POLE OF PV ARRAY SHALL BE
----� iREFERENCED
TO GROUND AT THE INVERTER
_-
11. ALL CONDUCTORS SHALL BE 6GOV, 90C
--.._ j
STANDARD COPPER, ALL CONDUCTORS SHALL
I
BE THWN.2 OR EQUAL.
12. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5%
13. ALL CONDUCTORS SHALL BE IN CONDUIT
UJ I
UNLESS OTHERWISE NOTED - SEE ELECTRICAL
I
LINE DIAGRAM
14. ALL WORK SHALL COMPLY WITH THE 2013
NATIONAL ELECTRICAL CODE. 2013 CALIFORNIA
i
ELECTRICAL CODE AND THE 2013 CALIFORNIA
I
BUILDING CODE
15. EXACT CONDUIT RUN LOCATIONS SUBJECT TO
CHANGE
•'
16. A GROUND FAULT DETECTION INTERRUPTION
'
(GFDI) DEVICE IS INTEGRATED WITH THE
INVERTER IN ACCORDANCE WITH NECICEC
690.5
17. AC CONDUCTORS SHALL BE COLOR CODED AS
FOLLOWS: PHASE A -BLACK. PHASE BRED.
PHASE C -BLUE. NEUTRAL -WHITEIGREY
18. MAXIMUM DEAD LOAD CONTRIBUTED FROM
!
SOLAR ARRAY SHALL NOT EXCEED 3.0 PSF.
19. NOTIFY UTILITY PROVIDER PRIOR TO
ACTIVATION
_
20. SEE SHEET 2 FOR REQUIRED SIGNAGE
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAzlo LANE
LA QUINTA, CA 92253
PARCEL #:766032023
CONTRACTOR INFORMATION
CK ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIO #3 550
X
CITY OF LA QUIiNTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY �_
REV. DESCRIPTION DATE
A
B
C
D
DATE: 1/4/16 SITE
PLAN
DRAFTER: CNG2 PV -.I' . I
LIVING GREEN INC.
802 S. EL CAMINO REAL,
SAN CLEMENTE, CA 92672
PH: (949) 748 - 0701
CONTRACTOR
CK ELECTRIC
204 BAUTISMOS LN.
SAN CLEMENTE, CA. 92672
PH. 949.748-0701
CL# 354550
Q0
I
N
W
�O
U-
Z Z Z co
U-)
W0 J^ J N
V5 CL O
LtJZNQQ
IYOLL U00
I
cO
~
^^
LL
F_F-�QN
Q
i-Q0zN
ti
=F- �CU
O Z
= ti
F-
Y
L
O
J
SHEET TITLE:
SITE PLAN,
GENERAL NOTES AND
ELECTRIC DIAGRAM
ache 1!8'•1'-0'
w. SSA
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAzlo LANE
LA QUINTA, CA 92253
PARCEL #:766032023
CONTRACTOR INFORMATION
CK ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIO #3 550
X
CITY OF LA QUIiNTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY �_
REV. DESCRIPTION DATE
A
B
C
D
DATE: 1/4/16 SITE
PLAN
DRAFTER: CNG2 PV -.I' . I
aPV
MODULES
J FIRE CLEARANCE AREA
F
® OBSTRUCTIONS
ROOF PENETRATION POINTS
- RAFTERS
— - — RAILS
���� PROPERTY LINES
SYSTEM OVERVIEW
-
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
N
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
(F� Sing/e
�
CUSTOMER INFORMATION
r
rQ�yMFN�
NADER KHOSHNIYATI
77-555 Tom FAZIO LANE
SP4CINC
LA QUINTA, CA 92253
/
'
PARCEL #: 766032023
CONTRACTOR INFORMATION
."� /'
CK ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
Al ���
(949) 748-0701
C/edrd \
KENT FARMER
\ -� l jl
�ce
CIO #3 550
/
X
RgFTF�'S `0.
i J J
C.
%
R1
ATTACHMENT DETAIL
SCALE: 3/16° = 1'-0°
TAG
ROOF INFORMATION
REV.
DESCRIPTION
DATE
MOUNTING INFORMATION
R1 18 MODULES,
FLAT TILE ROOF, 2020 AZIMUTH, 10 TILT, FLUSH MOUNTED
A
PV EQUIPMENT INFORMATION
MOUNTING SYSTEM MANUFACTURER: UNIRAC 144 RAILS WITH PROSOLAR SOLARWEDGE
B
TOTAL WEIGHT OF MODULES & RACKING
(LBS): 920.88
MODULE WEIGHT:
47.6 LBS
C
NUMBER OF ATTACHMENT POINTS:
36
MODULES SQ. FT.
21.47
D
WEIGHT (LBS) / ATTACHMENT POINT
25.58
ARRAY SQ. FT.
386.42
DATE: 1/4/16
ATTACHMENT LAYOUT
TOTAL SURFACE AREA OF PV MODULES (SQ.FT.): 386.42
RACKING WEIGHT:
3.56 LBS/MODULES
PV -2
DRAFTER: CNG2
DISTRIBUTED WEIGHT OF PV MODULE ON ROOF (LBS/SQ.FT.): 2.38
ROOF LOAD (MODULE WEIGHT / MODULE AREA): 2.22 LBS/SQ.FT.
ATTACHMENT SPACING DETAILS
CONDUIT DETAILS
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
Max Cantilever 33% Rail Span: 48'x 33% i 16
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
100 Rail Span: 4'
BELL Box
DC (PV) OR AC RAIN TIGHT, STEEL
(MICROINVERTER) CABLE EMT CONNECTOR.
STRAIN RELIEF GALVANIZED FLASHING,
9"x 12 " BASE, 1
MODULE 2
NO -CALK COLLAR
RAFTER
N
0
0
0
ND CLAMP
I (L x 25%) Max.
_j
ON TINUOUS RAIL
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAZio LANE
LA QUINTA, CA 92253
STRUT STRAP EMT CONDUIT
PARCEL #: 766032023
CONTRACTOR INFORMATION
\V
8" TYP.
FLEX CONDUIT THROUGH ATTIC
CK ELECTRIC
•
OINt OF PENETRATION
1204 Los BAUTismos LANE
12" Typ. is I ID CLAMP
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
ATTACHMENT DETAILS
GROUNDING DETAIL
C1014550
X
T -BOLT
PV MODULES END CLAMP
INSTALL ON PV MODULES & RACKING
CITY OF LA QUINTA
ATTACH ILSCO GBL-4DBT
UL 2703 LISTED GROUNDING LUGS
(FOR EXTERIOR/WET LOCATIONS)
BUILDING & SAFETY DEPT
APPROVED
0 L -FOOT BRACKET
r�i0
UNIRAC SUPPORT RAIL N
UNIRAC SUPPORT RAIL 0 EXTENSION LEG STRUT
W/STAINLESS STEEL MACHINE SCREW
PV MODULEL
FOR CONSTRUCTI0
DATE BY
L -FOOT BRACKET HOT MOP L -FOOT BRACKET
PROSOLAR STANDOFF w/ROCK ROOF PROSOLAR STANDOFF
Ll
ONE CONTINUES SOLID
COPPER GROUND WIRE
411 X 8" Rafters, 24" O.C.
REV.
DESCRIPTION
DATE
(1) 5/16"x3.5" HANGER BOLT
(1) 5/16"x3.5" HANGER BOLT (MIN. 2.5" EMBEDDED)
RACKING
NITS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL
NOT DISCONNECT THE BONDING CONNECTION
B
c
D
(MIN. 2.5" EMBEDDED)
BETWEEN ANY OTHER PIECES.
DATE: 1/4/16
ATTACHMENT DETAILS
PV -201
DRAFTER:CNG2
PARTIAL FRAMING DETAIL
MODULE
HEIGHT DETAIL
SYSTEM OVERVIEW
.
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
a
CUSTOMER INFORMATION
N
NADER KHOSHNIYATI
o
ivw
77-555 Tom FAZIo LANE
Li
J
0
LA QUINTA, CA 92253
o
- - 0
�
0
~
0
PARCEL #:766032023
CONTRACTOR INFORMATION
o
w
Q
cD
_ __— 1,= _ =-- _ _ _ _ _ _ _ — — —_� _ _ — __
�� -- _— 4" x8" Rafters, 24" O.C. _— -- ---
-------------
-- —
CK ELECTRIC
4
-------------
--
I
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIZ#3550
X
EQuIPMENT ELEVATION
VIEW
INSIDE
UTILITY TO PV
ROOM ARRAY
1
INV I
M
M
S P 1
^
REV.
DESCRIPTION
DATE
0
v
PB
A
C
D
DATE: 1/4/16
ELEVATION DETAILS
GRADE
DRAFTER: CNG 2
PV-2. 2
JUNCTION BOX
sl CAUTION:
L SOLAR ELECTRIC SYSTEM CONNECTED J
PHOTOVOLTAIC POWER SOURCE
PER NEC 690.31(E)(3) & IF 605.11.1.2
EMT CONDUIT RACEWAYS
WARNING: PHOTOVOLTAIC
POWER SOURCE
PER NEC 690.31(E)(3) & IF 605.11.1.2
DC conduit, raceways, enclosures, cable assemblies and
junction boxes. Use every 10', at every tum, above and
below penetrations, and all DC combiner junction boxes
per IFC 605.11.1.4 & NEC 690.31 (E)(3).
DC DISCONNECT
PV SYSTEM DC DISCONNECT ,
OPERATING CURRENT:
8 IA
OPERATING VOLTAGE:
350V
MAXIMUM SYSTEM VOLTAGE:
500V
23.38 A
SHORT CIRCUIT CURRENT:
INVERTER 1 PER NEC 690.53
PHOTOVOLTAIC
DC DISCONNECT
PER 605.11.1, IFC 605.11.14,
NEC 690.15 & NEC 690.14 (C)(2)
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH LINE AND
LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT
WHEN SOLAR MODULES
ARE EXPOSED TO SUNLIGHT
PER NEC 690.17(4)
CAUTION
PV SOLAR SYSTEM INSTALLED.
WHEN POWER DISCONNECTED SOLAR PANELS AND
WIRING IN CONDUITS TO INVERTER MAY REMAIN
ENERGIZED DURING DAYLIGHT HOURS.
FORMAT:
(1) WHITE LETTERING ON A RED BACKGROUND. PER NEC 690.35.(F)
(2) MINIMUM Y INCHES LETTER HEIGHT.
(3) ALL LETTERS SHALL BE CAPITALIZED
(4) ARIAL OR SIMILAR FONT, NON -BOLD.
MATERIAL:
REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE
FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR
WEATHER RATING). DURABLE ADHESIVE MATERIALS
AC PV COMBINER
PHOTOVOLTAIC AC DISCONNECT AC DISCONNECT
MAXIMUM AC OPERATING CURRENT: 31.25A PHOTOVOLTAIC AC DISCONNECT
MAXIMUM AC OPERATING VOLTAGE: 240V MAXIMUM AC OPERATING CURRENT: 31.25A
Per NEC 690.54 MAXIMUM AC OPERATING VOLTAGE: 240V
® WARNING 111
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE AND
LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION
PER NEC 690.17(4)
WARNING: PHOTOVOLTAIC
POWER SOURCE
PER NEC 690.31(E)(3) & IF 605.11.1.2
WARNING
SOLAR CIRCUITS ONLY.
NO OTHER LOADS
ALLOWED.
When It's A Microlnverter System
PV SYSTEM IS SUPPLIED WITH
MICROINVERTERS LOCATED AT ROOF
MOUNTED PANELS
Per NEC 690.54
PHOTOVOLTAIC
AC DISCONNECT
Per NEC 690.14(C)(2) & 690.15
MAIN SERVICE PANEL
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE AND
LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION
PER NEC 690.17(4)
WARNING:
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
PER NEC 110.27(C) & OSHA 1910.145(F)(7)
When Using Transformerless Inverters
WARNING
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAICC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
PER NEC 690.35.(F)
MAIN SERVICE DISCONNE
MAIN PV SYSTEM
DISCONNECT
PER NEC 690.14(C)(2), IFC 605.11.1,
IFC 605 11.14, NEC 690.15 & NEC 690.53
CAUTION:
[SOLAR ELECTRIC SYSTEM CONNECTED
PER NEC 690.14(C)(2), IFC 605.11.1,
IFC 605.14.1.4, NEC 690.15 & NEC 690.53
SOLAR DISCONNECT
PER NEC 605.11.1
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAZIo LANE
LA QUINTA, CA 92253
PARCEL #: 766032023
CONTRACTOR INFORMATION
CK ELECTRIC
1204 LOS BAUTISMOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIO #3 550
X
REV. DESCRIPTION DATE
A
B
C
D
DATE: 1/4/16 NEC FIRE
LABELS
DRAFTER: CNG2 PV _3
D
PV MODULE INFORMATION
(18) SOLARWORLD SW XL 315M
POWER AT STC: 315W
POWER AT PTC: 275.6W
V -OC (OPEN -CIRCUIT VOLTAGE) 45.6V
V -MP (MAX -POWER VOLTAGE) 36.5V
I -SC (SHORT-CIRCUIT CURRENT) 9.35A
I -MP (MAX -POWER CURRENT) 8.71A
MNFR V -OC TEMP COEFFICIENT: -0.3%/°C
(I-sc x 1.25 x 1.25) : 14.61A
PM
AC 60A KNIFE -BLADE AC DISCONNECT
AMBIENT TEMPERATURE INFORMATION
AMBIENT TEMP. : 52° C
AMBIENT TEMP. ABOVE ROOF: 74° C
EXTREME MIN TEMP. : -5° C
VOLTAGE DROP INFORMATION
TOTAL DC VOLTAGE DROP % : 0.76
TOTAL AC VOLTAGE DROP % : 0.55
TOTAL SYSTEM VOLTAGE DROP % :1.31
0�
zz
L W
U z
Q W
D
>C3_
0- WL
0I-_
z z
U �
0 -
of D
> 0
CL W U,
STRING INFORMATION
TAG DETAILS
A 9 MoD's, 2021 Az, 101 TILT
B 9 MoD's, 2021 Az, 101 TILT
MSP MAIN SERVICE PANEL INFORMATION
400A MSP W/400A MAIN BREAKER
120/240V, 3W, 10, Top -FED MSP
PV INTERCONNECTION: BREAKER
DE -RATE MAIN BREAKER ? NO
(MSP RATING x 120%) : 480A
PV LOAD: 40
TOTAL AMPS ON MSP: 440
DC.I DC.2
OP (18) SOLAREDGE P400
MAXIMUM SYSTEM VOLTAGE : 80V
MAX I -SC OF CONNECTED MODULE : 10A
MAX POWER PER STRING : 525OW
INVERTER I MAX POWER: 2835W
(2835W / 350V) : 8. IA
DC.1
(4) #10 AWG PV -WIRE
(2) #6 AWG BARE COPPER GROUND
IN FREE AIR TO J -BOX
AMPERAGE 14.61
PER NEC 310.15(8)(3)(A) : 0.8
PER NEC 310.18(B)(2)(A) : 0.5
(14.61) / (0.8 x 0.5) : 36.53
DISTANCE IN FEET 10
VOLTAGE DROP % : 0.15
DC.2
(4) #10 AWG THWN-2
(1) #10 AWG THWN-2 GROUND
3/4" FLEX CONDUIT THROUGH ATTIC
AMPERAGE 14.61
PER NEC 310.15(B)(3)(A) : 0.8
PER NEC 310.18(B)(2)(A) : 0.76
(14.61) / (0.8 x 0.76) : 24.03
DISTANCE IN FEET 40
VOLTAGE DROP % : 0.61
INV. I SOLAREDGE SE6000A-US
MAX OUTP6T CURRENT: 25A
(25 x 1.25) = 31.25A
MINIMUM OCPD: 35A
MAXIMUM INPUT VOLTAGE: 500V
MAXIMUM SYSTEM VOLTAGE: 350V
NUMBER OF MPPT'S: I
MAX NUMBER OF STRINGS: 2
INVERTER EFFICIENCY: 97.5%
TRANSFORMERLESS (Y/N): YES
C
+
+ DC
AC 8Lf
N
j G
t
t
UL
.L
LISTED
M PPT
AC.1
(3) #10 AWG THWN-2
(1) #10 AWG THWN-2 GROUND
3/4" EMT CONDUIT ON INTERIOR WALL
AMPERAGE 31.25
PER NEC 310.15(B)(3)(A) : I
PER NEC 310.18(B)(2)(A) : 0.76
(31.25) / 0 x 0.76) : 41.12
DISTANCE IN FEET 5
VOLTAGE DROP % : 0.16
200A SUB -PANEL LUG ONLY
(N) PV BREAKER : 40A
TOTAL OUT -PUT : 40A
AC. 2
(3) #8 AWG THWN-2
(1) #10 AWG THWN-2 GROUND
3/4" EMT INTERIOR To EXTERIOR WALL
AMPERAGE 40
PER NEC 310.15(B)(3)(A) : I
PER NEC 310.18(B)(2)(A) : 0.76
(40) / (I x 0.76) : 52.63
DISTANCE IN FEET 10
VOLTAGE DROP % : 0.26
Ground Rod
(E) GROUNDING
ELECTRODE
AC. 3
(3) #8 AWG THWN-2
(1) #10 AWG THWN-2 GROUND
3/4" EMT CONDUIT ON EXTERIOR WALL
AMPERAGE 40
PER NEC 310.15(B)(3)(A) : I
PER NEC 310.18(B)(2)(A) : 0.76
(40) / 0 x 0.760: 52.63
DISTANCE IN FEET 5
VOLTAGE DROP % : 0.13
SYSTEM OVERVIEW
5.67 KW SYSTEM
(18) SOLARWORLD SW XL 315M
(18) SOLAREDGE P400
SOLAREDGE SE6000A-US
CUSTOMER INFORMATION
NADER KHOSHNIYATI
77-555 Tom FAZIO LANE
LA QUINTA, CA 92253
PARCEL #:766032023
CONTRACTOR INFORMATION
CK ELECTRIC
1204 LOS BAUTISmOS LANE
SAN CLEMENTE, CA 92672
(949) 748-0701
KENT FARMER
CIO#3 550
X
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
REV.1 DESCRIPTION DATE
A
B
C
D
DATE: 1/4/16 SINGLE LINE DIAGRAM
DRAFTER: CNG2 I PV -4
mum
Sunmodule%
r,FWA, •
1
SW 315 Xl MONO 31REALVALUE
TUV Power controlled:
rOvah41n1. a Lowest measuring tolerance in industry
'I�� Every component is tested to meet
3 times IEC requirements
J
#= Designed to withstand heavy
accumulations of snow and ice
•':;; Sunmodule Plus:
Positive performance tolerance
'J
aI
25-year linear performance warranty
and 10 -year product warranty
I'
Glass with anti -reflective coating
tdjEC61115World-class quality Safety tested,
IEC 61730
H glowing sandrnf.-11.IEC 60068 h66 v1
Fully -automated production lines and seamless monitoring of the process and mate- D e .,�nmPniare�ftan<e.IEC61116
•Salt mist corrosion. IEC 61101
rial ensure the quality that the company sets as its benchmark for its sites worldwide. •Periodieinspestim G us
UL 1703
• Periodif ins°eftion
SolarWorld Plus -Sorting ".,led
Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules
that have greater than or equal to the nameplate rated power. �r-1� L_J
IF Home Innovation
NGIf GaFFM CFI. -e-
25 -year linear performance guarantee and extension of product warranty to 10 years
SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course ave
of 25 years, a significant added value compared to the two-phase warranties com-
mon in the industry, along with our industry -first 10 -year product warranty."
'in accordance with the applicable SolarWorld Limited Warranty at purchase.
www.solarworld.com/warranty
sola rworld.com
Sunmodule/
SW 315 XL MONO (33mm frame)
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)"
Maximum power
Pm
315 Wp
Open circuit voltage
V°,
45.6 y
Maximum power point voltage
Vmpp
36.5 V
Short circuit current
I,�
9.35 A
Maximum power point current
Imo'
8.71 A
Module efficiency
15.73
15.79%
'STC: 1000 W/ml, 25'C, AM 1.5
1) Measuring tolerance (P_,) traceable to TUV
THERMAL CHARACTERISTICS
Rheinland: +/- 2% (TUV Power Controlled).
NOCT
Two rail system 113 psf downward
64 psf upward
46 °C
TC 1..
'Please refer to the Sunmodule installation
these load cases.
ADDITIONAL DATA
0.042 %/°C
TC V.,
-0 Wp /+5 Wp
-0.304 %/°C
TCP"-------
Module leads
-0.43%/°C
Operating temperature
1
-40°C to 85°C
1000 W/ml
800 W/mr
600 W/ml
- _-- 400 W/ml -
200 W/ml
100 W/ml
Module voltage IV) V.
4.20
(106.65)
t
37.8 (961) -
00
6
11.53
33.6V
0.26 (6.6)
(292.85)
Maximum power point current I.P.,
7.18 A
N
a
TTIIIII ^
I
1710.35(9)
OQ O
H
e
�-
1;1:�4
1
15.73
25A
Number of bypass diodes
(399.50)
Design Loads'
Two rail system 113 psf downward
64 psf upward
39.4 (1001) -
1.30 (33)
All units provided are imperial. SI units provided in parentheses.
SolarWorld AG reserves the right to make specification changes without notice.
PERFORMANCE AT 800 W/m2, NOCT, AM 1.5
Maximum power P,,,.
240.9 Wp
Open circuit voltage V.
39.8 V
Maximum power point voltage V,,,PP
33.6V
Short circuit current 1,17.77
.............................................................................................................................................
A
.......................
Maximum power point current I.P.,
7.18 A
Minor reduction in efficiency under partial load conditions at 25•C: at 200 W/m=,100%
(+/-2%) of the STC efficiency (1000 w/ml) is achieved.
COMPONENT MATERIALS
Cells per module
72
Cell type
Mono crystalline
Cell dimensions
6.17 in x 6.17 in (156.75 x 156.75 mm)
Front
Tempered glass (EN 12150)
Frame
Clear anodized aluminum
Weight
47.6 lbs (21.6 kg)
SYSTEM INTEGRATION PARAMETERS
�-
Maximum system voltage SC 11/NEC
1000 y
Maximum reverse current
25A
Number of bypass diodes
3
Design Loads'
Two rail system 113 psf downward
64 psf upward
Design Loads'
Edge mounting 178 psf downward
23 psf upward
'Please refer to the Sunmodule installation
these load cases.
ADDITIONAL DATA
instructions for the details associated with
Powersorting'
-0 Wp /+5 Wp
J -Box
IP65
Module leads
PV wire per UL4703 with H4 connectors
Module type (UL 1703)
1
Glass
Low iron tempered with ARC
S W-01-7105US-104-2015
0.43 (1p Compatible with both "Top -Down"
and "Bottom" mounting methods
1 Grounding Locations:
- 4 locations along the length of the
module in the extended flange.
1.30 (33)
�-
1.14 (29) -�
S W-01-7105US-104-2015
solar =@@
SolarEdge Single Phase Inverters
For North America
SE3OOOA-US / SE38OOA-US / SE5O0OA-US / SE6OOOA-US /
SE76OOA-US / SE1OOOOA-US / SE1140OA-US
solar=eeSingle Phase Inverters for North America
SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US /
SE760OA-US / SE1000OA-US / SE1140OA-US
SE3000A-US
, SE380OA-US SESOOOA-US
SE6000A-US j SE760OA-US
, SE1000OA- US
SE1140OA-US
W
OUTPUT
.....................................................
775 x 315 x 260..........
Yes
..88:4/_40.1
..............
! Natural
Max. Input Voltage
..Max.
Natural Convection and internal
1
9980 @ 208V
Vdc
Nominal AC Power Output
3000
3800 5000
6000 7600
11400
VA
.........................
................
............... .................
................1................
�. ..................
34.5
Adc
5400 @ 208V
15.5 �.240y.. I .......
110800 @ 208V
...........
Max. AC Power Output
3300
4150
...,. I
6000 8350
i 10950.�240V
12000
VA
AC Output Voltage Min: Nom.-Max.ltl
Yes
183 - 208 - 229 Vac
...............
..............:I
.......... I
...........
AC Output Voltage Min: Nom: Max.jtl
97.7
98.2
98.3 98i......98....
98
211 - 240 - 264 Vac
97.5
( i................
I......
••
i............
97'5g..............Y.......�a1
,.%o...................97.5
.....................................................................
AC Frequency Min: Nom: Max.'tl
.........................I............
................
.................
59.3 - 60 - 60.5 (with
..........i..................
HI country setting 57 - 60 -
.......................
60.5)
..............
...
Hz
Nighttime Power Consumption
24 @ 208v I
i
48 @ 208V
W
Max. Continuous Output Current
12.5
16 f
1..
25 32
47.5
A
Supported Communication Interfaces
............I ..
.............. 21.x° .240V l
................ i ................
l ...42 .@ 240V... ............
.................
GFDI Threshold
.....................................................................................................................................................................
1
A
Utility Monitoring, Islanding Protection,
Country Configurable Thresholds
Yes
is installed"
...........
Yes
INPUT
Maximum DC Power (STC) ... ................
4050
.. 5100
1 6750 8100 •. 1025
13500
15350
W
Transformer -less, Ungrounded
................................................................................................................................................................................
.....................................................
775 x 315 x 260..........
Yes
..88:4/_40.1
..............
! Natural
Max. Input Voltage
..Max.
Natural Convection and internal
500
Vdc
Nom. DC Input Voltage
325 @ 208V / 350 @ 240V
Vdc
.............................................
Max. Input Current(')
9.5
13
..................................
16.5 @ 208V I I
II 1 23
18.........:..................30,5
33 @ 208V 1
(
34.5
Adc
15.5 �.240y.. I .......
@ 240V.. , ..................
.
Max. Input Short Circuit Current
..........................................................................
................ 45
.....................................................................................
Adc
Reverse -Polarity Protection
.....................................................................................................................................................................
Yes
Ground -Fault Isolation Detection
600kn Sensitivity
............ .
...........
MaximuminverterEfficiency
97.7
98.2
98.3 98i......98....
98
Wei hted Efficient
97.5
98
I1983..,.
@ 208V
97 @ 208VCEC
97'5g..............Y.......�a1
,.%o...................97.5
gg240V97'5 .97..
........................................ ........@.........
97.5 240. ..................
...........
Nighttime Power Consumption
< 2.5
_ <4
W
ADDITIONAL FEATURES
Supported Communication Interfaces
..............................................................Isr
RS485, RS232, Ethernet, ZigBee (optional)
..................................................................
Revenue Grade Data, ANSI C12.1
.....................................................................................................................................................................
Optional
...........
Rapid Shutdown — NEC 2014 690.12
Functionality enabled when SolarEdge rapid shutdown kit
is installed"
STANDARD COMPLIANCE
Safety
.....................................................................................................................................................................
U11741, UL16998, UL1998 , CSA 22.2
...........
Grid Connection Standards
...................................................................................................p
IEEE1547
_Emissions
.................................................I..........................
FCC art15 class_B_____
INSTALLATION SPECIFICATIONS
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance
Superior efficiency (98%)
Small, lightweight and easy to install on provided bracket
Built-in module -level monitoring
Internet connection through Ethernet or Wireless
Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
Pre -assembled Safety Switch for faster installation
Optional — revenue grade data, ANSI C12.1
USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -ISRAEL www.solaredge.us
ACoutput conduit size / AWG range
..........................................
DC input conduit size / # of strings /
AWG.rang?.............. .... I..........
Dimensions with Safety Switch
(HxWxD).
...............................
Weight with Safety Switch
...............................
Cooling
3/4" minimum / 16-6 AWG 1
3/4" minimum / 8-3 AWG
3/4" minimum / 1-2 strings / 16-6 AWG3/4"
minimum / 1-2 strings /
..........................................................................
.....1..4..6 .A.....�........ -.WG .............
30.Sx12.5x7.2/775x315x184 i
i
30.5x12.5x10.5/
.....................................................
775 x 315 x 260..........
51.2/23:?..........�...................54:�.�24:�. ;..........
..88:4/_40.1
..............
! Natural
1 convection
Natural Convection and internal
Fans (user replaceable)
fan (user
........................................... re laceable
Noise < 25 < 50
Min. -Max. Operating Temperature
Ran a-13 to +140 / -25 to +60 (-40 to +60 version available(")
g......................................................................................................................................
Protection Rating NEMA 3R
.............................................................................................................................................
n) for other regional settings please contact SolarEdge support.
A higher current source may be used; the inverter will limit its input current to the values stated.
Revenue grade inverter P/N: SExxxxA-USOOONNR2 (for 7600W inverter:SE7600A-US002NNR2).
Rapid shutdown kit P/N: SE1000-RSD-Sl.
tsr-40version P/N: SExxxxA-USOOONNU4 (for 7600W inverter:SE7600A-US002NNU4).
in /
mm....
Ib /. kgg..
I
solar - •
SolarEdge Power Optimizer
Module Add -On For North America
P300 / P400 / P405
PV power optimization at the module -level
M
solar" e � � SolarEdge Power Optimizer
Module Add -On for North America
P300 / P400 / P405
P300 P400 P405
(for 60 -cell modules) (for 72 & 96 -cell modules) (for thin film modules)
INPUT
Rated Input DC Powerltl300
........................................................................................................
400
405
W
..............................................................................................................................................................i.............
Absolute Maximum Input Voltage
48
80
125
Vdc
YRI; at lowest temperature) ....................
.......................................
.................................
Pxxx-5 series
.................
5x5.97x1.085x5.97x1.37
.... ..............................
MPPT Operating Ranke ......
8 48
....................
8 80
...................................................;.............
12.5-105
•. Vdc
Maximum Short Circuit Current (Isc)10
................................ ..................
.........................
.................................................................i.............
Adc
Maximum DC Input Current ...................
Connector.
..Input ..................................
12:5 .................................................,.
Adc ....
..Maximum Efficiency...............................................................................99.5
.....................................................
�.....�D......
Weighted Efficiency................................................................................98:8.
1.2 / 3.9
..................................
...............................................
.....%.....
Overvoltage Category
Pxxx 2•seri••es
II
............................................................
IP65 / NEMA4
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
..........................................
........ ...................................IP68
Maximum Output Current. 15 ................ Adc
...............
Maximum Output Voltage 60 85 _ j Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
_
Safety Output Voltage per Power Optimizer 1 Vdc
STANDARD COMPLIANCE
�..w.
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3..................................................
Ler u`4 Safety IEC62109-1 (class II safety), UL1741
...................................................................................................................................... ................. I.............
Neal
RoHS Yes
tantY o INSTALLATION SPECIFICATIONS
— Up to 25% more energy
— Superior efficiency (99.5%)
— Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
— Flexible system design for maximum space utilization
— Fast installation with a single bolt
Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter safety
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA
www.solaredge.us
..Maximum....Allowed....Syste.......m Voltage .............
.........................
........................................................................................................
1000
Pxxx-2 series
141 x 212 x 40.5 / 5.55 x 8.34 x 1.59
Dimensions (W x L x H)
..................................................................
128x152x27.5/
.........................
128x152x35/
......
128x152x48/
.................................
Pxxx-5 series
.................
5x5.97x1.085x5.97x1.37
.... ..............................
,..
5x5.97x1.89
Weight (including cables)
Pxxx-2 series
.xxx- .seri...........................................................................
950/2.1
I.Pxxx 5 series
.................
770..1: �...........
...........930 / 2.05 930/2.05
.......................................
Connector.
..Input ..................................
. .........................................MC4
Compatible..........................................
Output Wire Type / Connector
.............................
Double Insulated; MC4 Compatible
Output Wire Len&th
0:95 / 3.0
.................:...................
1.2 / 3.9
..................................
Operating Temperature Range
-40 - +85 / -40 - +185
Pxxx 2•seri••es
............................................................
IP65 / NEMA4
Protection Rating ••� • �•.•••
i.Pxxx-5 series ......
..........................................
........ ...................................IP68
.............................................
/ NEMA61?.......... .................................
RelativeHumidity ...................................................................................................................
0-100
I Rated STC power of the module. Module of up to+S%power tolerance allowed.
PV SYSTEM DESIGN USING
A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
Minimum String Length
(Power. Optimizers)
Maximum String Length
(Power Optimizers) ................... ... ...
Maximum Power per String
Parallel Strings of Different Lengths
or Orientations
In It is not allowed to mix P405 with P300/P400/P600/P700 in one string.
8
25
..................... .
5250
.................... .