BSOL2015-024678-495 CALLE TAM PICO U LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSOL201S-0246 Property Address: 79555 N TOM FAZIO LN APN: 766032016 ' Application Description: KHOSHIYATI/5.6kW PV SYSTEM - (18) 31OW PANELS/(1) INVERTER Property Zoning: Application Valuation: $15,000.00 Applicant: CTSUPY C K- ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: CSO License No.: 354550 Date: ,��5-Z6/C Contractor. - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work, himself or herself through his or her own.employees, provided that the improvements are not intended or offered for sale. If, however; the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: 11111111111111111111 31 VOICE (760).777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/15/2016 Owner: NADER & SHIRLEY•KHOSHNIYATI 19 LAGUNA DR LAGUNA BEACH, -CA -92 7 Contractor: I) JAN C K ELECTRIC rtNr1FI l 01)1h' 1204 LOS BAUTI�N(��^Sb\I N�EVELOPInENTDI.Fr^ •'•' SAN CLEMENTE, CA92 �4-1�_--_ (949)218-5434 Llc. No.: 354550 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier: _ Policy Number: ' I certify that in the performance of the work for•which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Q.r ate:. 4/5- -20 / ,; Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 'APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance'of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of . work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county'ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. I - Date: =L�/J� ZOZe Signature (Applicant or Agent) FINANCIAL ' ' • DESCRIPTION ' ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 1/15/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DONN D REESE DEBIT MR252 064416 TSA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $24.17 1/15/16 PAID BY ' METHOD RECEIPT # CHECK # CLTD BY DONN D REESE DEBIT MR252 064416 TSA DESCRIPTION " ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 1/15/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DONN D REESE DEBIT MR252 064416 TSA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $24.17 $24.17 1/15/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DONN D REESE DEBIT MR252 064416 TSA DESCRIPTION ACCOUNT QTY AMOUNT - PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17 $24.17 1/15/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY DONN D REESE DEBIT. MR252. 064416 TSA Total Paid for ELECTRICAL: $96.68 $96.68 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 1/15/16 PAID BY METHOD. RECEIPT # CHECK # CLTD BY DONN D REESE DEBIT MR252 064416 TSA Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: Description: KHOSHIYATI/5.6kW PV SYSTEM - (18) 31OW PANELS/(1) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 12/22/2015 MFA Approved: Parcel No: 766032016 Site Address: 79555 N TOM FAZIO LN LA QUINTA,CA 92253 Subdivision: TR 27728 Block: Lot: 45 Issued: Lot Scl Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $15,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 PLAN CHECK -SUBMITTAL Details: 5.6kW SOLAR ARRAY - (18) 255W SOLARWORLD SW XL 315M+SOLAREDGE P400 OPTIMIZERS W/ (1) SOLAREDGE SE6000A-US-ZB-U- AFCI INVERTER [270SF] 2013 CALIFORNIA ELECTRICAL CODE. Printed: Friday, January 15, 2016 1:52:35 PM 1 of 3 -• #?w-1YS TEMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK -SUBMITTAL MARY FASANO 12/22/2015 12/22/2015 PER BURT, THIS PLAN CHECK CAN BE REVIEWED IN HOUSE .RECEIVED AND NOT SENT TO ESGIL CUSTOMER CAME IN WITH REVISED SET OF PLANS. OVER THE COUNTER PLAN CHECK. APPROVED. BSOL2015-0009 IS ALSO PUBLIC COUNTER VISIT LUIS URIBE 1/15/2016 1/15/2016 ON THIS ADDRESS WITH OUTSTANDING PLAN CHECK FEES. FEE WILL BE PAID ON BSOL2015-0009 BEFORE WE ISSUE THIS PERMIT. CONTRACTOR STATED THAT IS FINE. SPOKE WITH DONN REESE, 1ST REVIEW IS COMPLETE PLANS TELEPHONE CALL LUIS URIBE 12/29/2015 12/29/2015 ARE READY FOR CORRECTIONS. DONN ASKED IF I CAN EMAIL A COPY OF THE CORRECTIONS LIST -1 TOLD HIM NOT A PROBLEM. CORRECTIONS LIST WAS SENT VIA EMAIL. CONDITIONS Printed: Friday, January 15, 2016 1:52:35 PM 1 of 3 -• #?w-1YS TEMS INSPECTIONS PARENT PROJECTS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT C K ELECTRIC 1204 LOS BAUTISMOS SAN CLEMENTE CA 92672 LANE CONTRACTOR C K ELECTRIC 1204 LOS BAUTISMOS SAN CLEMENTE CA 92672 LANE OWNER NADER & SHIRLEY KHOSHNIYATI 19 LAGUNA DR LAGUNA BEACH CA 92651 FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY ....AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0. $1.00 $1.00 1/15/16 MR252 064416 DEBIT DONN D REESE TSA Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $24.17 1/15/16 MR252 064416 DEBIT DONN D REESE TSA FIRST 20 PV SYSTEM -ARRAY, 101-0000-42600 0 $24.17 $24.17 1/15/16 MR252 064416 DEBIT DONN D REESE . TSA FIRST 26 PC PV SYSTEM -MISC 101-0000-42403 0 $24.17 $24.17 1/15/16 MR252 064416 DEBIT DONN D REESE TSA EQUIPMENT PV SYSTEM -MISC 101-0000-42600 0 $24.17' $24.17 1/15/16 MR252 064416 DEBIT DONN D REESE TSA EQUIPMENT PC Total Paid for ELECTRICAL: $96.68 $96.68 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 1/15/16 MR252 064416 DEBIT DONN D REESE TSA Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: INSPECTIONS PARENT PROJECTS Printed: Friday, January 15, 2016 1:52:35 PM 2 of 3 CJ?� SYSTEMS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE, 1ST BLDG NS (1 WK) LUIS URIBE 12/22/2015 1/4/2016 12/29/2015 REVISIONS REQUIRED 2ND BLDG NS (1 LUIS URIBE WK) . 1/15/2016 1/15/2016 1/15/2016 APPROVED Printed: Friday, January 15, 2016 1:52:35 PM 3 of 3 �J CFEY SYSTIMS PLACARD SOLAR PV ARRAY WITH OPTIMIZERS ROOF MOUNTED f 4 i CAUTION POWER TO THE BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AT SHOWN i <N � �S SERVICE POINT UTILITY METERING SCONNECT 5 N S APPROVAL STAMP AND ADDITIONAL NOTES FOR THE CITY OF: LA QUINTA SHEET INDEX SYSTEM OVERVIEW • ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, PROJECT NOTES: COVER 5.67 KW SYSTEM RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN PLOT PLAN & PHOTOVOLTAIC LAYOUT : PV -I ATTACHMENT LAYOUT &CALCULATIONS: PV -2,i ATTACHMENT DETAILS: PV -2.1 (18) SoLARWoRLD SW XL 315 '�,N (18) SoLAREDGE P400 - BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. • PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE FIRE SIGNS/LABELS: PV -3 MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, SINGLE LINE DIAGRAM: PV -4 SOLAREDGE SE6000A-US MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF MANUFACTURE SPEC. SHEETS: ATTACHED GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC §690.4(B)) • PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND GENERAL NOTES • CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC CUSTOMER INFORMATION §690.4(E)) PERINEC 310.0(D) NADER KHOSHNIYATI • CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.8(C) • WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT 77-555 TOM FAZIO LANE WILL BE MAINTAINED IN ACCORDANCE WITH THE NEC 110.26 LA QUINTA, CA 92253 • EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. • SMOKE ALARMS AND CO2 ALARMS TO BE INSTALLED • STRUCTURAL MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED PARCEL #: 766032023 AND VERIFIED AS NECESSARY FOR LAG BOLT.PENETRATIONS BY CONTRACTOR. • SEAL CONNECTION POINTS WITH ROOF GRADE CONTRACTOR INFORMATION • ROOF PENETRATIONS ARE SEALED WITH SCHNEE MOREHEAD 7108 SEALANT. CK ELECTRIC 46 • PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. • PROVIDE GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN 1204 LOS BAUTISMOS LANE SERVICE GROUND ELECTRODE PER C.E.C. ARTICLE 250.50 THROUGH 250.86. SAN CLEMENTE, CA 92672 • GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM PROTECTION OF BARE ARMOR SHEATHED CABLE FOR ALL (949) 748-0701 CONDUCTOR SIZES. Q • ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE n PANEL. IJ ENT FARMER I O • INVERTER IS LISTED TO UL -1741 "UTILITY INTERACTIVE" • ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. [JAN 15 ` �^ I C+10 # . 55 2010 6!�,JJJ • ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2.Vi+�+rX • MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2% CON^ UNITYDEVELOK, hi DEFr'..-LLEjiJT • ALL CONDUCTORS SHALL BE CONDUIT UNLESS OTHERWISE NOTED.-`"`" CITY OF LA QUINTA BUILDING & SAFETY DEPT DEP�t VICINITY MAP PPROVED FOR CONSTRUCTION ATE �,r----=-----�._............ REV. DESCRIPTION A 1 -11641, 1B 4 C r D DATE: 1/4/16 SOV J Awl .� _ C0 VE DRAFTER: CNG2 N 'lel C \0 �� o PLOT PLAN & INSTALL LOCATION SCALE: I' = 30' PV (18) SOLARWORLD SW XL 315M OP (18) SOLAREDGE P400 MICRO MSP (E) 400A MSP W/ 400A MAIN BREAKER MSP -D MSP -U PM AC 60A KNIFE -BLADE AC DISCONNECT T SP 200A SUB -PANEL INV -1 SOLAREDGE SE6000A-US INV -2 INV -3 JB JUNCTION BOX PROPOSED PV CONDUIT RUN ABOVE ROOF J i — PROPOSED PV CONDUIT RUN THROUGH ATTIC -- PROPERTY LINES Q PV SOLAR MODULES - FLUSH MOUNTED ® ® VENTS & OBSTRUCTIONS ® CHIMNEY ® ROOF ACCESS POINT: ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.(R331.4.1 OF THE 2013 CRC) SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAZIO LANE LA QUINTA, CA 92253 PARCEL #:766032023 CONTRACTOR INFORMATION CK ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIO #35 50 X CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATE _ BY REV. DESCRIPTION DATE A B C D DATE: 1/4/16 PLOT PLAN DRAFTER: CNG2 P V — I SOLAR PANEL ARMY SYMBOL LEGEND MA%NNM VOLTAGE: 680V SVSTEN CALCULATION: SOLAR PANEL ARRAY W9- GAS -:GAS- DPf CLRMUM IUOT VOLTAGE: 39.N M0.UMUM POWER CURRENT: 36SV („�,%E P.I1FD Mml % 13Y • BPi M (9) 3IS%Y PROSERISE %L (91 SOLAR EDGE OC SHORT GRWIT CURREM: B.9}A 25p MODULE X 1.25 = 31.25A [USE 40A DBL BRKj MODULES BY SOLAR WORLD }�% 01`MTINOCURRENT: _6A G (9) SOLAR EDGE DC SE E000AAIS }WA SUB AC DISCONNECT INVERTER P_EL Y�' EMT CONWIT x PANEL %DDA SERVILE OPRMMERS 1`3W I j (a) Q TH_N3 (f) e8 THHN Gf W I• 3. JUNCTION BOX PROVIDES TRANSITION FROM I UL USTEDUS YA'EMTCONOUR Y"EMTCONOUIT 4. PROVIDE CONTINUOUS GROUND TO MAIN F%MMP ELECTRICAL PANEL. C.E.0 2010 250.5.250.86 ES CABLES (�)p10 THNN.2 M.", TNWN-} I ®•• ROOFING MATERIAL CONCRETE TILE SHEETED CABLE FOR ALL CONDUCTOR SIZES. (1)N1 MHN•GRN (1)ae MNN GRN DISCONNECT 4. INSTALLATION OF (1) 6.0 KW INVERTER wDw SERVICE GROUND IN MAIN SERVICE PANEL. SOLAR PANEL ARMY SYMBOL LEGEND ® PHOTOVOLTAIC MODULE (9) 31RY PROSERISE XL - Gn5 ',IGAS- W9- GAS -:GAS- lAODULE9 By 9DUR W f (91 SOLAR EDGE OC II 8.9 app BRK fiOgMP OP ITLI.ERS P- CK ELECTRIC _�. 1 I . G I I SE E000AAIS }WA SUB AC DISCONNECT INVERTER P_EL PV ELECTRICAL LINE DIAGRAM NTS -I ! I I I j 0 I• I _1. - ..... I I I 0 fP 7-7- - -.... I li I I J S/A' DR CO!®MT Y101t (A) O is THN OR, C i 1x}!'0}]}•f }e}.Ie1 q6u - _ _ SITE PLAN „B=,•o SYMBOL LEGEND ® PHOTOVOLTAIC MODULE - Gn5 ',IGAS- W9- GAS -:GAS- GAS- GAS- GAS='GAS 802 S. EL CAMINO REAL, f I I--------T- II -- - - - - -- ------------- CK ELECTRIC _�. 1 I . G I I 400 AMP SERVICE ROOF DATA -I ! I I I j ; SCOPE OF WORK 3. JUNCTION BOX PROVIDES TRANSITION FROM I ROOF SLOPE 4:12 SLOPE 4. PROVIDE CONTINUOUS GROUND TO MAIN .I I j..,...._........... ELECTRICAL PANEL. C.E.0 2010 250.5.250.86 i� - - _ I ®•• ROOFING MATERIAL CONCRETE TILE SHEETED CABLE FOR ALL CONDUCTOR SIZES. F- DISCONNECT 4. INSTALLATION OF (1) 6.0 KW INVERTER L SERVICE GROUND IN MAIN SERVICE PANEL. 7. INVERTER MODEL IS LISTED TO UL 1741 ROOF STRUCTURE WOOD FRAMING ' II I. ARRAY, PROJECT INFORMATION, GENERAL LOCKABLE. 240V AC. 30 AMP. f NOTES AND SINGLE LINE DIAGRAM ! AND DC SIDE TO BE SIZED ACCORDING TO NEC 2. PV ARRAY MANUFACTURE DATA SHEETS SECTION 690. AND SINGLE LINE DIAGRAM ----� iREFERENCED i� 3. PRO SOLAR'FAST JACK' INSTALLATION 11. ALL CONDUCTORS SHALL BE 6GOV, 90C --.._ j MANUAL - GAS - G4R - GAS - GAS --- 12. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% 13. ALL CONDUCTORS SHALL BE IN CONDUIT UJ I UNLESS OTHERWISE NOTED - SEE ELECTRICAL I LINE DIAGRAM iT NATIONAL ELECTRICAL CODE. 2013 CALIFORNIA �. ELECTRICAL CODE AND THE 2013 CALIFORNIA I BUILDING CODE 15. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE •' 16. A GROUND FAULT DETECTION INTERRUPTION ' (GFDI) DEVICE IS INTEGRATED WITH THE INVERTER IN ACCORDANCE WITH NECICEC 690.5 17. AC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: PHASE A -BLACK. PHASE BRED. PHASE C -BLUE. NEUTRAL -WHITEIGREY PANEL SO ARMY min': ! SOLAR ARRAY SHALL NOT EXCEED 3.0 PSF. 19. NOTIFY UTILITY PROVIDER PRIOR TO 4 _ 118) 2) sTRW(GS OF (9) 315W I PROSERIM XL PANELS BY / ..I..• I WORLD mm (13) SOLAR EDGE OC OPTIMIZERS 1=-+�T•my�aw=nmt�-', (+SOLAR y' ! _ .._...i.s• _("+._'_ ' .�� J -BOX -j ---:-J C=,- ; : AWSe I I J S/A' DR CO!®MT Y101t (A) O is THN OR, C i 1x}!'0}]}•f }e}.Ie1 q6u - _ _ SITE PLAN „B=,•o - LNYERTER AND SUB PANEL IN , UTILITY ROOM I 1 I I!••� I i� \ E it AODA MAIN PANEL SERVICE \ E 60A A/C \ f DISCONNECT F \IF SYMBOL LEGEND ® PHOTOVOLTAIC MODULE MODULE TO INVERTER JOB SITE INFORMATION CONNECTION 802 S. EL CAMINO REAL, ADDRESS: 77.555 TOM FAZIO LN. PH: (949) 748 - 0701 PITCH CITY: LA OUINTA, CA 92253 NORTH NORTH ARROW CK ELECTRIC UTILITY PROVIDER: IMPERIAL IRRIGATION DIST. 204 BAUTISMOS LN. MODULES BY SOLAR WORLD WITH (18) P900 400 AMP SERVICE SOLAR EDGE DC OPTIMIZERS -SEE -I ! SYSTEM SIZE 5.7 KW SYSTEM I j LINE DIAGRAM SCOPE OF WORK 3. JUNCTION BOX PROVIDES TRANSITION FROM iARRAY 1. INSTALLATION OF (18) PHOTOVOLTAIC 4. PROVIDE CONTINUOUS GROUND TO MAIN SOLAR PANELS. ELECTRICAL PANEL. C.E.0 2010 250.5.250.86 i� 2. INSTALLATION OF (18) DC OPTIMIZERS I cO ~ ^^ LL INVERTER TO BE MIN. PROTECTION OF ARMOR 3. INSTALLATION OF (1) 30A DIC SHEETED CABLE FOR ALL CONDUCTOR SIZES. F- DISCONNECT 4. INSTALLATION OF (1) 6.0 KW INVERTER L SERVICE GROUND IN MAIN SERVICE PANEL. 7. INVERTER MODEL IS LISTED TO UL 1741 �i SHEET INDEX ' II I. ARRAY, PROJECT INFORMATION, GENERAL LOCKABLE. 240V AC. 30 AMP. f NOTES AND SINGLE LINE DIAGRAM ! AND DC SIDE TO BE SIZED ACCORDING TO NEC 2. PV ARRAY MANUFACTURE DATA SHEETS SECTION 690. AND SINGLE LINE DIAGRAM ----� iREFERENCED i� 3. PRO SOLAR'FAST JACK' INSTALLATION 11. ALL CONDUCTORS SHALL BE 6GOV, 90C --.._ j MANUAL - GAS - G4R - GAS - GAS --- - LNYERTER AND SUB PANEL IN , UTILITY ROOM I 1 I I!••� I i� \ E it AODA MAIN PANEL SERVICE \ E 60A A/C \ f DISCONNECT F \IF SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAzlo LANE LA QUINTA, CA 92253 PARCEL #:766032023 CONTRACTOR INFORMATION CK ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIO #3 550 X CITY OF LA QUIiNTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY �_ REV. DESCRIPTION DATE A B C D DATE: 1/4/16 SITE PLAN DRAFTER: CNG2 PV -.I' . I SYMBOL LEGEND ® PHOTOVOLTAIC MODULE MODULE TO INVERTER CONNECTION 802 S. EL CAMINO REAL, DIRECTION OF ROOF PH: (949) 748 - 0701 PITCH CONTRACTOR NORTH NORTH ARROW CK ELECTRIC 1. PV ARRAY CONTAINS 1181315W PROSERIES XL 204 BAUTISMOS LN. MODULES BY SOLAR WORLD WITH (18) P900 SAN CLEMENTE, CA. 92672 SOLAR EDGE DC OPTIMIZERS -SEE -I ! MANUFACTURE DATA ON SHEET 2 2. WIRING TO INVERTERS IS PER ELECTRICAL I j LINE DIAGRAM Q0 3. JUNCTION BOX PROVIDES TRANSITION FROM iARRAY WIRING TO CONDUIT 4. PROVIDE CONTINUOUS GROUND TO MAIN I i ELECTRICAL PANEL. C.E.0 2010 250.5.250.86 i� S. GROUND ELECTRODE CONDUCTOR FROM I cO ~ ^^ LL INVERTER TO BE MIN. PROTECTION OF ARMOR ti SHEETED CABLE FOR ALL CONDUCTOR SIZES. F- 6. ALL GROUNDS SMALL BE CONNECTED TO MAIN L SERVICE GROUND IN MAIN SERVICE PANEL. 7. INVERTER MODEL IS LISTED TO UL 1741 -UTILITY INTERACTIVE' O 8.AC DISCONNECTS SHALL BE VISIBLE OPEN, J LOCKABLE. 240V AC. 30 AMP. i 9. EQUIPMENT GROUNDING CONDUCTORS ON AC ! AND DC SIDE TO BE SIZED ACCORDING TO NEC ! SECTION 690. 10. NEGATIVE POLE OF PV ARRAY SHALL BE ----� iREFERENCED TO GROUND AT THE INVERTER _- 11. ALL CONDUCTORS SHALL BE 6GOV, 90C --.._ j STANDARD COPPER, ALL CONDUCTORS SHALL I BE THWN.2 OR EQUAL. 12. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% 13. ALL CONDUCTORS SHALL BE IN CONDUIT UJ I UNLESS OTHERWISE NOTED - SEE ELECTRICAL I LINE DIAGRAM 14. ALL WORK SHALL COMPLY WITH THE 2013 NATIONAL ELECTRICAL CODE. 2013 CALIFORNIA i ELECTRICAL CODE AND THE 2013 CALIFORNIA I BUILDING CODE 15. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE •' 16. A GROUND FAULT DETECTION INTERRUPTION ' (GFDI) DEVICE IS INTEGRATED WITH THE INVERTER IN ACCORDANCE WITH NECICEC 690.5 17. AC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: PHASE A -BLACK. PHASE BRED. PHASE C -BLUE. NEUTRAL -WHITEIGREY 18. MAXIMUM DEAD LOAD CONTRIBUTED FROM ! SOLAR ARRAY SHALL NOT EXCEED 3.0 PSF. 19. NOTIFY UTILITY PROVIDER PRIOR TO ACTIVATION _ 20. SEE SHEET 2 FOR REQUIRED SIGNAGE SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAzlo LANE LA QUINTA, CA 92253 PARCEL #:766032023 CONTRACTOR INFORMATION CK ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIO #3 550 X CITY OF LA QUIiNTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY �_ REV. DESCRIPTION DATE A B C D DATE: 1/4/16 SITE PLAN DRAFTER: CNG2 PV -.I' . I LIVING GREEN INC. 802 S. EL CAMINO REAL, SAN CLEMENTE, CA 92672 PH: (949) 748 - 0701 CONTRACTOR CK ELECTRIC 204 BAUTISMOS LN. SAN CLEMENTE, CA. 92672 PH. 949.748-0701 CL# 354550 Q0 I N W �O U- Z Z Z co U-) W0 J^ J N V5 CL O LtJZNQQ IYOLL U00 I cO ~ ^^ LL F_F-�QN Q i-Q0zN ti =F- �CU O Z = ti F- Y L O J SHEET TITLE: SITE PLAN, GENERAL NOTES AND ELECTRIC DIAGRAM ache 1!8'•1'-0' w. SSA SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAzlo LANE LA QUINTA, CA 92253 PARCEL #:766032023 CONTRACTOR INFORMATION CK ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIO #3 550 X CITY OF LA QUIiNTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY �_ REV. DESCRIPTION DATE A B C D DATE: 1/4/16 SITE PLAN DRAFTER: CNG2 PV -.I' . I aPV MODULES J FIRE CLEARANCE AREA F ® OBSTRUCTIONS ROOF PENETRATION POINTS - RAFTERS — - — RAILS ���� PROPERTY LINES SYSTEM OVERVIEW - 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M N (18) SOLAREDGE P400 SOLAREDGE SE6000A-US (F� Sing/e � CUSTOMER INFORMATION r rQ�yMFN� NADER KHOSHNIYATI 77-555 Tom FAZIO LANE SP4CINC LA QUINTA, CA 92253 / ' PARCEL #: 766032023 CONTRACTOR INFORMATION ."� /' CK ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 Al ��� (949) 748-0701 C/edrd \ KENT FARMER \ -� l jl �ce CIO #3 550 / X RgFTF�'S `0. i J J C. % R1 ATTACHMENT DETAIL SCALE: 3/16° = 1'-0° TAG ROOF INFORMATION REV. DESCRIPTION DATE MOUNTING INFORMATION R1 18 MODULES, FLAT TILE ROOF, 2020 AZIMUTH, 10 TILT, FLUSH MOUNTED A PV EQUIPMENT INFORMATION MOUNTING SYSTEM MANUFACTURER: UNIRAC 144 RAILS WITH PROSOLAR SOLARWEDGE B TOTAL WEIGHT OF MODULES & RACKING (LBS): 920.88 MODULE WEIGHT: 47.6 LBS C NUMBER OF ATTACHMENT POINTS: 36 MODULES SQ. FT. 21.47 D WEIGHT (LBS) / ATTACHMENT POINT 25.58 ARRAY SQ. FT. 386.42 DATE: 1/4/16 ATTACHMENT LAYOUT TOTAL SURFACE AREA OF PV MODULES (SQ.FT.): 386.42 RACKING WEIGHT: 3.56 LBS/MODULES PV -2 DRAFTER: CNG2 DISTRIBUTED WEIGHT OF PV MODULE ON ROOF (LBS/SQ.FT.): 2.38 ROOF LOAD (MODULE WEIGHT / MODULE AREA): 2.22 LBS/SQ.FT. ATTACHMENT SPACING DETAILS CONDUIT DETAILS SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M Max Cantilever 33% Rail Span: 48'x 33% i 16 (18) SOLAREDGE P400 SOLAREDGE SE6000A-US 100 Rail Span: 4' BELL Box DC (PV) OR AC RAIN TIGHT, STEEL (MICROINVERTER) CABLE EMT CONNECTOR. STRAIN RELIEF GALVANIZED FLASHING, 9"x 12 " BASE, 1 MODULE 2 NO -CALK COLLAR RAFTER N 0 0 0 ND CLAMP I (L x 25%) Max. _j ON TINUOUS RAIL CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAZio LANE LA QUINTA, CA 92253 STRUT STRAP EMT CONDUIT PARCEL #: 766032023 CONTRACTOR INFORMATION \V 8" TYP. FLEX CONDUIT THROUGH ATTIC CK ELECTRIC • OINt OF PENETRATION 1204 Los BAUTismos LANE 12" Typ. is I ID CLAMP SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER ATTACHMENT DETAILS GROUNDING DETAIL C1014550 X T -BOLT PV MODULES END CLAMP INSTALL ON PV MODULES & RACKING CITY OF LA QUINTA ATTACH ILSCO GBL-4DBT UL 2703 LISTED GROUNDING LUGS (FOR EXTERIOR/WET LOCATIONS) BUILDING & SAFETY DEPT APPROVED 0 L -FOOT BRACKET r�i0 UNIRAC SUPPORT RAIL N UNIRAC SUPPORT RAIL 0 EXTENSION LEG STRUT W/STAINLESS STEEL MACHINE SCREW PV MODULEL FOR CONSTRUCTI0 DATE BY L -FOOT BRACKET HOT MOP L -FOOT BRACKET PROSOLAR STANDOFF w/ROCK ROOF PROSOLAR STANDOFF Ll ONE CONTINUES SOLID COPPER GROUND WIRE 411 X 8" Rafters, 24" O.C. REV. DESCRIPTION DATE (1) 5/16"x3.5" HANGER BOLT (1) 5/16"x3.5" HANGER BOLT (MIN. 2.5" EMBEDDED) RACKING NITS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION B c D (MIN. 2.5" EMBEDDED) BETWEEN ANY OTHER PIECES. DATE: 1/4/16 ATTACHMENT DETAILS PV -201 DRAFTER:CNG2 PARTIAL FRAMING DETAIL MODULE HEIGHT DETAIL SYSTEM OVERVIEW . 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US a CUSTOMER INFORMATION N NADER KHOSHNIYATI o ivw 77-555 Tom FAZIo LANE Li J 0 LA QUINTA, CA 92253 o - - 0 � 0 ~ 0 PARCEL #:766032023 CONTRACTOR INFORMATION o w Q cD _ __— 1,= _ =-- _ _ _ _ _ _ _ — — —_� _ _ — __ �� -- _— 4" x8" Rafters, 24" O.C. _— -- --- ------------- -- — CK ELECTRIC 4 ------------- -- I 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIZ#3550 X EQuIPMENT ELEVATION VIEW INSIDE UTILITY TO PV ROOM ARRAY 1 INV I M M S P 1 ^ REV. DESCRIPTION DATE 0 v PB A C D DATE: 1/4/16 ELEVATION DETAILS GRADE DRAFTER: CNG 2 PV-2. 2 JUNCTION BOX sl CAUTION: L SOLAR ELECTRIC SYSTEM CONNECTED J PHOTOVOLTAIC POWER SOURCE PER NEC 690.31(E)(3) & IF 605.11.1.2 EMT CONDUIT RACEWAYS WARNING: PHOTOVOLTAIC POWER SOURCE PER NEC 690.31(E)(3) & IF 605.11.1.2 DC conduit, raceways, enclosures, cable assemblies and junction boxes. Use every 10', at every tum, above and below penetrations, and all DC combiner junction boxes per IFC 605.11.1.4 & NEC 690.31 (E)(3). DC DISCONNECT PV SYSTEM DC DISCONNECT , OPERATING CURRENT: 8 IA OPERATING VOLTAGE: 350V MAXIMUM SYSTEM VOLTAGE: 500V 23.38 A SHORT CIRCUIT CURRENT: INVERTER 1 PER NEC 690.53 PHOTOVOLTAIC DC DISCONNECT PER 605.11.1, IFC 605.11.14, NEC 690.15 & NEC 690.14 (C)(2) WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT PER NEC 690.17(4) CAUTION PV SOLAR SYSTEM INSTALLED. WHEN POWER DISCONNECTED SOLAR PANELS AND WIRING IN CONDUITS TO INVERTER MAY REMAIN ENERGIZED DURING DAYLIGHT HOURS. FORMAT: (1) WHITE LETTERING ON A RED BACKGROUND. PER NEC 690.35.(F) (2) MINIMUM Y INCHES LETTER HEIGHT. (3) ALL LETTERS SHALL BE CAPITALIZED (4) ARIAL OR SIMILAR FONT, NON -BOLD. MATERIAL: REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS AC PV COMBINER PHOTOVOLTAIC AC DISCONNECT AC DISCONNECT MAXIMUM AC OPERATING CURRENT: 31.25A PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING VOLTAGE: 240V MAXIMUM AC OPERATING CURRENT: 31.25A Per NEC 690.54 MAXIMUM AC OPERATING VOLTAGE: 240V ® WARNING 111 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION PER NEC 690.17(4) WARNING: PHOTOVOLTAIC POWER SOURCE PER NEC 690.31(E)(3) & IF 605.11.1.2 WARNING SOLAR CIRCUITS ONLY. NO OTHER LOADS ALLOWED. When It's A Microlnverter System PV SYSTEM IS SUPPLIED WITH MICROINVERTERS LOCATED AT ROOF MOUNTED PANELS Per NEC 690.54 PHOTOVOLTAIC AC DISCONNECT Per NEC 690.14(C)(2) & 690.15 MAIN SERVICE PANEL WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION PER NEC 690.17(4) WARNING: TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL PER NEC 110.27(C) & OSHA 1910.145(F)(7) When Using Transformerless Inverters WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAICC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED PER NEC 690.35.(F) MAIN SERVICE DISCONNE MAIN PV SYSTEM DISCONNECT PER NEC 690.14(C)(2), IFC 605.11.1, IFC 605 11.14, NEC 690.15 & NEC 690.53 CAUTION: [SOLAR ELECTRIC SYSTEM CONNECTED PER NEC 690.14(C)(2), IFC 605.11.1, IFC 605.14.1.4, NEC 690.15 & NEC 690.53 SOLAR DISCONNECT PER NEC 605.11.1 SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAZIo LANE LA QUINTA, CA 92253 PARCEL #: 766032023 CONTRACTOR INFORMATION CK ELECTRIC 1204 LOS BAUTISMOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIO #3 550 X REV. DESCRIPTION DATE A B C D DATE: 1/4/16 NEC FIRE LABELS DRAFTER: CNG2 PV _3 D PV MODULE INFORMATION (18) SOLARWORLD SW XL 315M POWER AT STC: 315W POWER AT PTC: 275.6W V -OC (OPEN -CIRCUIT VOLTAGE) 45.6V V -MP (MAX -POWER VOLTAGE) 36.5V I -SC (SHORT-CIRCUIT CURRENT) 9.35A I -MP (MAX -POWER CURRENT) 8.71A MNFR V -OC TEMP COEFFICIENT: -0.3%/°C (I-sc x 1.25 x 1.25) : 14.61A PM AC 60A KNIFE -BLADE AC DISCONNECT AMBIENT TEMPERATURE INFORMATION AMBIENT TEMP. : 52° C AMBIENT TEMP. ABOVE ROOF: 74° C EXTREME MIN TEMP. : -5° C VOLTAGE DROP INFORMATION TOTAL DC VOLTAGE DROP % : 0.76 TOTAL AC VOLTAGE DROP % : 0.55 TOTAL SYSTEM VOLTAGE DROP % :1.31 0� zz L W U z Q W D >C3_ 0- WL 0I-_ z z U � 0 - of D > 0 CL W U, STRING INFORMATION TAG DETAILS A 9 MoD's, 2021 Az, 101 TILT B 9 MoD's, 2021 Az, 101 TILT MSP MAIN SERVICE PANEL INFORMATION 400A MSP W/400A MAIN BREAKER 120/240V, 3W, 10, Top -FED MSP PV INTERCONNECTION: BREAKER DE -RATE MAIN BREAKER ? NO (MSP RATING x 120%) : 480A PV LOAD: 40 TOTAL AMPS ON MSP: 440 DC.I DC.2 OP (18) SOLAREDGE P400 MAXIMUM SYSTEM VOLTAGE : 80V MAX I -SC OF CONNECTED MODULE : 10A MAX POWER PER STRING : 525OW INVERTER I MAX POWER: 2835W (2835W / 350V) : 8. IA DC.1 (4) #10 AWG PV -WIRE (2) #6 AWG BARE COPPER GROUND IN FREE AIR TO J -BOX AMPERAGE 14.61 PER NEC 310.15(8)(3)(A) : 0.8 PER NEC 310.18(B)(2)(A) : 0.5 (14.61) / (0.8 x 0.5) : 36.53 DISTANCE IN FEET 10 VOLTAGE DROP % : 0.15 DC.2 (4) #10 AWG THWN-2 (1) #10 AWG THWN-2 GROUND 3/4" FLEX CONDUIT THROUGH ATTIC AMPERAGE 14.61 PER NEC 310.15(B)(3)(A) : 0.8 PER NEC 310.18(B)(2)(A) : 0.76 (14.61) / (0.8 x 0.76) : 24.03 DISTANCE IN FEET 40 VOLTAGE DROP % : 0.61 INV. I SOLAREDGE SE6000A-US MAX OUTP6T CURRENT: 25A (25 x 1.25) = 31.25A MINIMUM OCPD: 35A MAXIMUM INPUT VOLTAGE: 500V MAXIMUM SYSTEM VOLTAGE: 350V NUMBER OF MPPT'S: I MAX NUMBER OF STRINGS: 2 INVERTER EFFICIENCY: 97.5% TRANSFORMERLESS (Y/N): YES C + + DC AC 8Lf N j G t t UL .L LISTED M PPT AC.1 (3) #10 AWG THWN-2 (1) #10 AWG THWN-2 GROUND 3/4" EMT CONDUIT ON INTERIOR WALL AMPERAGE 31.25 PER NEC 310.15(B)(3)(A) : I PER NEC 310.18(B)(2)(A) : 0.76 (31.25) / 0 x 0.76) : 41.12 DISTANCE IN FEET 5 VOLTAGE DROP % : 0.16 200A SUB -PANEL LUG ONLY (N) PV BREAKER : 40A TOTAL OUT -PUT : 40A AC. 2 (3) #8 AWG THWN-2 (1) #10 AWG THWN-2 GROUND 3/4" EMT INTERIOR To EXTERIOR WALL AMPERAGE 40 PER NEC 310.15(B)(3)(A) : I PER NEC 310.18(B)(2)(A) : 0.76 (40) / (I x 0.76) : 52.63 DISTANCE IN FEET 10 VOLTAGE DROP % : 0.26 Ground Rod (E) GROUNDING ELECTRODE AC. 3 (3) #8 AWG THWN-2 (1) #10 AWG THWN-2 GROUND 3/4" EMT CONDUIT ON EXTERIOR WALL AMPERAGE 40 PER NEC 310.15(B)(3)(A) : I PER NEC 310.18(B)(2)(A) : 0.76 (40) / 0 x 0.760: 52.63 DISTANCE IN FEET 5 VOLTAGE DROP % : 0.13 SYSTEM OVERVIEW 5.67 KW SYSTEM (18) SOLARWORLD SW XL 315M (18) SOLAREDGE P400 SOLAREDGE SE6000A-US CUSTOMER INFORMATION NADER KHOSHNIYATI 77-555 Tom FAZIO LANE LA QUINTA, CA 92253 PARCEL #:766032023 CONTRACTOR INFORMATION CK ELECTRIC 1204 LOS BAUTISmOS LANE SAN CLEMENTE, CA 92672 (949) 748-0701 KENT FARMER CIO#3 550 X CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY REV.1 DESCRIPTION DATE A B C D DATE: 1/4/16 SINGLE LINE DIAGRAM DRAFTER: CNG2 I PV -4 mum Sunmodule% r,FWA, • 1 SW 315 Xl MONO 31REALVALUE TUV Power controlled: rOvah41n1. a Lowest measuring tolerance in industry 'I�� Every component is tested to meet 3 times IEC requirements J #= Designed to withstand heavy accumulations of snow and ice •':;; Sunmodule Plus: Positive performance tolerance 'J aI 25-year linear performance warranty and 10 -year product warranty I' Glass with anti -reflective coating tdjEC61115World-class quality Safety tested, IEC 61730 H glowing sandrnf.-11.IEC 60068 h66 v1 Fully -automated production lines and seamless monitoring of the process and mate- D e .,�nmPniare�ftan<e.IEC61116 •Salt mist corrosion. IEC 61101 rial ensure the quality that the company sets as its benchmark for its sites worldwide. •Periodieinspestim G us UL 1703 • Periodif ins°eftion SolarWorld Plus -Sorting ".,led Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than or equal to the nameplate rated power. �r-1� L_J IF Home Innovation NGIf GaFFM CFI. -e- 25 -year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course ave of 25 years, a significant added value compared to the two-phase warranties com- mon in the industry, along with our industry -first 10 -year product warranty." 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty sola rworld.com Sunmodule/ SW 315 XL MONO (33mm frame) PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)" Maximum power Pm 315 Wp Open circuit voltage V°, 45.6 y Maximum power point voltage Vmpp 36.5 V Short circuit current I,� 9.35 A Maximum power point current Imo' 8.71 A Module efficiency 15.73 15.79% 'STC: 1000 W/ml, 25'C, AM 1.5 1) Measuring tolerance (P_,) traceable to TUV THERMAL CHARACTERISTICS Rheinland: +/- 2% (TUV Power Controlled). NOCT Two rail system 113 psf downward 64 psf upward 46 °C TC 1.. 'Please refer to the Sunmodule installation these load cases. ADDITIONAL DATA 0.042 %/°C TC V., -0 Wp /+5 Wp -0.304 %/°C TCP"------- Module leads -0.43%/°C Operating temperature 1 -40°C to 85°C 1000 W/ml 800 W/mr 600 W/ml - _-- 400 W/ml - 200 W/ml 100 W/ml Module voltage IV) V. 4.20 (106.65) t 37.8 (961) - 00 6 11.53 33.6V 0.26 (6.6) (292.85) Maximum power point current I.P., 7.18 A N a TTIIIII ^ I 1710.35(9) OQ O H e �- 1;1:�4 1 15.73 25A Number of bypass diodes (399.50) Design Loads' Two rail system 113 psf downward 64 psf upward 39.4 (1001) - 1.30 (33) All units provided are imperial. SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. PERFORMANCE AT 800 W/m2, NOCT, AM 1.5 Maximum power P,,,. 240.9 Wp Open circuit voltage V. 39.8 V Maximum power point voltage V,,,PP 33.6V Short circuit current 1,17.77 ............................................................................................................................................. A ....................... Maximum power point current I.P., 7.18 A Minor reduction in efficiency under partial load conditions at 25•C: at 200 W/m=,100% (+/-2%) of the STC efficiency (1000 w/ml) is achieved. COMPONENT MATERIALS Cells per module 72 Cell type Mono crystalline Cell dimensions 6.17 in x 6.17 in (156.75 x 156.75 mm) Front Tempered glass (EN 12150) Frame Clear anodized aluminum Weight 47.6 lbs (21.6 kg) SYSTEM INTEGRATION PARAMETERS �- Maximum system voltage SC 11/NEC 1000 y Maximum reverse current 25A Number of bypass diodes 3 Design Loads' Two rail system 113 psf downward 64 psf upward Design Loads' Edge mounting 178 psf downward 23 psf upward 'Please refer to the Sunmodule installation these load cases. ADDITIONAL DATA instructions for the details associated with Powersorting' -0 Wp /+5 Wp J -Box IP65 Module leads PV wire per UL4703 with H4 connectors Module type (UL 1703) 1 Glass Low iron tempered with ARC S W-01-7105US-104-2015 0.43 (1p Compatible with both "Top -Down" and "Bottom" mounting methods 1 Grounding Locations: - 4 locations along the length of the module in the extended flange. 1.30 (33) �- 1.14 (29) -� S W-01-7105US-104-2015 solar =@@ SolarEdge Single Phase Inverters For North America SE3OOOA-US / SE38OOA-US / SE5O0OA-US / SE6OOOA-US / SE76OOA-US / SE1OOOOA-US / SE1140OA-US solar=eeSingle Phase Inverters for North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US SE3000A-US , SE380OA-US SESOOOA-US SE6000A-US j SE760OA-US , SE1000OA- US SE1140OA-US W OUTPUT ..................................................... 775 x 315 x 260.......... Yes ..88:4/_40.1 .............. ! Natural Max. Input Voltage ..Max. Natural Convection and internal 1 9980 @ 208V Vdc Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA ......................... ................ ............... ................. ................1................ �. .................. 34.5 Adc 5400 @ 208V 15.5 �.240y.. I ....... 110800 @ 208V ........... Max. AC Power Output 3300 4150 ...,. I 6000 8350 i 10950.�240V 12000 VA AC Output Voltage Min: Nom.-Max.ltl Yes 183 - 208 - 229 Vac ............... ..............:I .......... I ........... AC Output Voltage Min: Nom: Max.jtl 97.7 98.2 98.3 98i......98.... 98 211 - 240 - 264 Vac 97.5 ( i................ I...... •• i............ 97'5g..............Y.......�a1 ,.%o...................97.5 ..................................................................... AC Frequency Min: Nom: Max.'tl .........................I............ ................ ................. 59.3 - 60 - 60.5 (with ..........i.................. HI country setting 57 - 60 - ....................... 60.5) .............. ... Hz Nighttime Power Consumption 24 @ 208v I i 48 @ 208V W Max. Continuous Output Current 12.5 16 f 1.. 25 32 47.5 A Supported Communication Interfaces ............I .. .............. 21.x° .240V l ................ i ................ l ...42 .@ 240V... ............ ................. GFDI Threshold ..................................................................................................................................................................... 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes is installed" ........... Yes INPUT Maximum DC Power (STC) ... ................ 4050 .. 5100 1 6750 8100 •. 1025 13500 15350 W Transformer -less, Ungrounded ................................................................................................................................................................................ ..................................................... 775 x 315 x 260.......... Yes ..88:4/_40.1 .............. ! Natural Max. Input Voltage ..Max. Natural Convection and internal 500 Vdc Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Vdc ............................................. Max. Input Current(') 9.5 13 .................................. 16.5 @ 208V I I II 1 23 18.........:..................30,5 33 @ 208V 1 ( 34.5 Adc 15.5 �.240y.. I ....... @ 240V.. , .................. . Max. Input Short Circuit Current .......................................................................... ................ 45 ..................................................................................... Adc Reverse -Polarity Protection ..................................................................................................................................................................... Yes Ground -Fault Isolation Detection 600kn Sensitivity ............ . ........... MaximuminverterEfficiency 97.7 98.2 98.3 98i......98.... 98 Wei hted Efficient 97.5 98 I1983..,. @ 208V 97 @ 208VCEC 97'5g..............Y.......�a1 ,.%o...................97.5 gg240V97'5 .97.. ........................................ ........@......... 97.5 240. .................. ........... Nighttime Power Consumption < 2.5 _ <4 W ADDITIONAL FEATURES Supported Communication Interfaces ..............................................................Isr RS485, RS232, Ethernet, ZigBee (optional) .................................................................. Revenue Grade Data, ANSI C12.1 ..................................................................................................................................................................... Optional ........... Rapid Shutdown — NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed" STANDARD COMPLIANCE Safety ..................................................................................................................................................................... U11741, UL16998, UL1998 , CSA 22.2 ........... Grid Connection Standards ...................................................................................................p IEEE1547 _Emissions .................................................I.......................... FCC art15 class_B_____ INSTALLATION SPECIFICATIONS The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -ISRAEL www.solaredge.us ACoutput conduit size / AWG range .......................................... DC input conduit size / # of strings / AWG.rang?.............. .... I.......... Dimensions with Safety Switch (HxWxD). ............................... Weight with Safety Switch ............................... Cooling 3/4" minimum / 16-6 AWG 1 3/4" minimum / 8-3 AWG 3/4" minimum / 1-2 strings / 16-6 AWG3/4" minimum / 1-2 strings / .......................................................................... .....1..4..6 .A.....�........ -.WG ............. 30.Sx12.5x7.2/775x315x184 i i 30.5x12.5x10.5/ ..................................................... 775 x 315 x 260.......... 51.2/23:?..........�...................54:�.�24:�. ;.......... ..88:4/_40.1 .............. ! Natural 1 convection Natural Convection and internal Fans (user replaceable) fan (user ........................................... re laceable Noise < 25 < 50 Min. -Max. Operating Temperature Ran a-13 to +140 / -25 to +60 (-40 to +60 version available(") g...................................................................................................................................... Protection Rating NEMA 3R ............................................................................................................................................. n) for other regional settings please contact SolarEdge support. A higher current source may be used; the inverter will limit its input current to the values stated. Revenue grade inverter P/N: SExxxxA-USOOONNR2 (for 7600W inverter:SE7600A-US002NNR2). Rapid shutdown kit P/N: SE1000-RSD-Sl. tsr-40version P/N: SExxxxA-USOOONNU4 (for 7600W inverter:SE7600A-US002NNU4). in / mm.... Ib /. kgg.. I solar - • SolarEdge Power Optimizer Module Add -On For North America P300 / P400 / P405 PV power optimization at the module -level M solar" e � � SolarEdge Power Optimizer Module Add -On for North America P300 / P400 / P405 P300 P400 P405 (for 60 -cell modules) (for 72 & 96 -cell modules) (for thin film modules) INPUT Rated Input DC Powerltl300 ........................................................................................................ 400 405 W ..............................................................................................................................................................i............. Absolute Maximum Input Voltage 48 80 125 Vdc YRI; at lowest temperature) .................... ....................................... ................................. Pxxx-5 series ................. 5x5.97x1.085x5.97x1.37 .... .............................. MPPT Operating Ranke ...... 8 48 .................... 8 80 ...................................................;............. 12.5-105 •. Vdc Maximum Short Circuit Current (Isc)10 ................................ .................. ......................... .................................................................i............. Adc Maximum DC Input Current ................... Connector. ..Input .................................. 12:5 .................................................,. Adc .... ..Maximum Efficiency...............................................................................99.5 ..................................................... �.....�D...... Weighted Efficiency................................................................................98:8. 1.2 / 3.9 .................................. ............................................... .....%..... Overvoltage Category Pxxx 2•seri••es II ............................................................ IP65 / NEMA4 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) .......................................... ........ ...................................IP68 Maximum Output Current. 15 ................ Adc ............... Maximum Output Voltage 60 85 _ j Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) _ Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE �..w. EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3.................................................. Ler u`4 Safety IEC62109-1 (class II safety), UL1741 ...................................................................................................................................... ................. I............. Neal RoHS Yes tantY o INSTALLATION SPECIFICATIONS — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us ..Maximum....Allowed....Syste.......m Voltage ............. ......................... ........................................................................................................ 1000 Pxxx-2 series 141 x 212 x 40.5 / 5.55 x 8.34 x 1.59 Dimensions (W x L x H) .................................................................. 128x152x27.5/ ......................... 128x152x35/ ...... 128x152x48/ ................................. Pxxx-5 series ................. 5x5.97x1.085x5.97x1.37 .... .............................. ,.. 5x5.97x1.89 Weight (including cables) Pxxx-2 series .xxx- .seri........................................................................... 950/2.1 I.Pxxx 5 series ................. 770..1: �........... ...........930 / 2.05 930/2.05 ....................................... Connector. ..Input .................................. . .........................................MC4 Compatible.......................................... Output Wire Type / Connector ............................. Double Insulated; MC4 Compatible Output Wire Len&th 0:95 / 3.0 .................:................... 1.2 / 3.9 .................................. Operating Temperature Range -40 - +85 / -40 - +185 Pxxx 2•seri••es ............................................................ IP65 / NEMA4 Protection Rating ••� • �•.••• i.Pxxx-5 series ...... .......................................... ........ ...................................IP68 ............................................. / NEMA61?.......... ................................. RelativeHumidity ................................................................................................................... 0-100 I Rated STC power of the module. Module of up to+S%power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power. Optimizers) Maximum String Length (Power Optimizers) ................... ... ... Maximum Power per String Parallel Strings of Different Lengths or Orientations In It is not allowed to mix P405 with P300/P400/P600/P700 in one string. 8 25 ..................... . 5250 .................... .