Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0218
78-495 CALLE TAMPICO LA,QUINTA; CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: ECKLUND CONSTRUCTION 117 ARREZO CT PALM DESERT, CA 92211 �w 44vQumrw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BSOL2015-0218 80871 VISTA LAZO 762250010 SMITH / 12.4kW PV SYSTEM - (48) 270W PANELS/(2) INVERTER $46,400.00 J NOV. 3 0 2015 ... J COt': JiLiJiT 1iwEt.OP VILNI QEPAR' WENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class B License No.: 55838 Date: / 3� 5� Contractor: C Q OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption.'Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to _the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Nam Lender's Add 39 VOICE (760) 777-7125 FAX (760) 7774011 INSPECTIONS (760) 777-7153 Date: 11/30/2015 Owner: JACLIN C SMITH 80871 VISTA LAZO LA QUINTA, CA 92253 Contractor: ECKLUND CONSTRUCTION 117 ARREZO CT PALM DESERT, CA 92211 (760)200-4001 Llc. No.: 558389 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Secti n 3700 of the Labor Code, for the performance of the work for which this permit is issued: My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: _ C I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California,•and agree that, if I should become subject to the workers' compensation provisions of Section 370 f th or Code, I shall forthwith comply with those provisions. Date: �ll3d Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any actor omission related to the work being performed under or . following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state ws relating to building construction, and hereby authorize representatives of Wcit�i/tupon the above-mentioned property for inspection purposes. Date: 30/ Signature (Applicant or Agen o• o X� St D-��yN �. E E � 6 � � §b�i`I•,fi.�x �,�� if�� �`d?i'��.� ��: .'�'` .e. �'�., c,�ii':,�'1-'F:tihz"'�,� ,, rr .t �' JR4 T ¢ 3ib. 5 v�-.:�'�.4,��-3'';��« -5 �i � "`9E'•' fc:��-' 3.. "S -'Y �„uX"'F '�.F'3�'y:X ,�.;�E'. BSAS SB1473 FEE ;, 101,-0000-20306 0 .$2.00. " $0.00 .�?"i-±`�ckiE??4+, � N> ,�- :,4 � `�a�.sL-h`�.4':�"wr��x'' "L :S'SY Xz- E v'i•� �'sii�s�`sia-.�?" n." `ri' X'3•y. EN,i k%s,3n. RAIU:BY��: ����z� ``� 101 METHOD � � RECEIP-T # � 4 3 � �W";.z�. rtzv�::.. _:."yll s �"''S 'F>>F�k�;�:-..zr:+ '611I .ti��.� � �s� �' �sa�• ...��� Total Paid`for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 `. $0.00 `r z :a: ' WIN +: '»aye :y. . agfi. , ... DESCRIPTION� u ''. - i c t�' i ACCOUNT - :'sem-v- TY AMOUNT k PAID PAD AD TE; _ PV SYSTEM —ARRAY, FIRST 20 101-0000.42403 0— $24.17 $0.00 ON— RECE P # �4��C CK # CL•fD BYE pPAIDBY�'.IVIETID.p' '., ah .. ...«..' +t�'4..F ,..O. -'.. .... .� W ¢..=...,�i.......-'a'v.":.'�« f .,,.:' ,�`'.�,- C DESCRIPTION �-� �E.se,. i�.: °pi-�`'y'�'�:,�`<,��&'E. ' ��g� � qTY AMOUNT PAID PAID DATE �;. ,,Pi'�..�i.-a�(�..3.a,. �A000UNT -P.:.-....'>U'+.:"s^P`.ga...k..: - ,,• PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 .01 $24.17 $0:00 y-...•?'.�<< a: P..'Ay-4'I_3.»DL. +''B.Yn:.<. 1Ni. uEa � 0 to_.+ i 'f. �fs:xs1 UkD:!n$£:�< REC.E4IC Rr%+n�"&E `Y�C# M C BY .a'"g:�rh'nE , n a DESCRIPTION�?'t ACCOUNT�QTY x AMOUNTPAID PAIODATEx J PV SYSTEM - MISC EQUIPMENT 101=0000-42403 0 $48.34 $0.00 d _ RAN `;� MEfH 'i�:,, Nf.�!:. ,.< Y •-A <i. OhD } �`� s k:,..s' � § S1' �.$ `M5'3" #-b rrvn ?Y>»L, .3.. � � � � RECE r �r bfi��=,�:�Rw'�+ze:9�'i . .s i g � CHECK # � � � . ek#n..... �:�' CLTD 6Y : � _ :DESCRIPTION S i �" AGCUUNT� � ��z�'�s� QTYfn- � !¢.:;�. °�-vy�x-!.�c ivE '- : AMOUNT -L az PAID �=� •�•s+i(� PAID DATE' x. 3 `�r+ €.: . , •«..¢.T.>v,� .�° s� ?:, ??. ° r' . `v.:._,�.., ....etu2..?, 3 x., :.n_ .bT .''3�fi• + ss�rEIM-7,_ .� � � fn d 47a�': ki; PV SYSTEM -MISC EQUIPMENT -PC 3 ;. 101-0000-42600 0, $48.34 ' $0.00 y� �.5a' �:.�„�;. .. ,�.. ' A. ��- "x". � `S' p�k�?��, '� 'E. '� - k�'� r` �'"�'s 5 �� �>� '� ��`,���• �=PAID BY �� `�°��� k+�a-. �` a �.�`P`:�"' .:.... � . _ .: METHOD � 'n.� �z�",« �y - - :.rEi �'�� ���RECEIPT #��� ti u` - �;"✓&�"2:�:tF�i €QEF z'K�i w �Ta°c;.X.�,' �k'k:' E�' E: CLTD BYES .,� � - � 4 �GHECK"#`��� � �� Total Paid for:ELECTRICAL: $145:02. $0:00 f3CpExgni. 2-`4 - i - i ',`vY.a`sA�". 'R°i,.-�'a+t ., k^,€'s,€- •-2s,'.i-r':. .F `�'kaE9t AU 'ff4."a`' e` °�` ::W�. :. ?rt .ya��i, ":'l;,'YF.'?i`-$gg' q rDESCRI..PT�r� , :..:.. �QN :AMOUNT �Wffi WRPAID ri s PAIDDATE PERMIT ISSUANCE 101-0000-•42404 0 . • $91.85 $0.00 METHOD NNE kMINI r s-�"x,--�"�� RECEIPT # CHECK # CLTD BYE .:wx<.`xt. "r.'>� `�`�,x'`PM�."E.«•moi=': Total Paid for PERMIT ISSUANCE: $91.85.. $0:00 eT ALS f Description: SMITH / 12.4kW PV SYSTEM - (48) 270W PANELS/(2) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 11%2/2015 SGU Approved: 11/25/2015 LUR Parcel No: 762250010 Site Address: 80871 VISTA LAZO LA QUINTA,CA 92253 Subdivision: TR 28034 Block: Lot: 10 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $46,400.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 12.4kW SOLAR ARRAY - (48) 265W'CANADIAN SOLAR-CS6P-260M W/ (2) SOLAREDGE SE6000A-US-ZB-U-AFCI INVERTER [760SF] 100AMP LOAD CENTER & MAIN BREAKER DERATE TO 175AMP. 2013 CALIFORNIA ELECTRICAL CODE. Printed: Monday, November 30, 2015 2:43:18 PM 1 of 3 , SYSTEtitS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES SPOKE WITH DOUG ON THE PHONE AND HE ASKED IF I E-MAIL LUIS URIBE 11/10/2015 11/10/2015 COULD EMAIL THE CORRECTIONS TO HIM. CORRECTIONS HAVE BEEN SENT VIA EMAIL AND WAITTING FOR RESPONCES. NOTE STEPHANIE GUMPERT 11/18/2015 11/18/2015 RESPONSES BROUGHT IN SOPKE WITH DOUG. LET HIM KNOW THAT I NEED THE CORRECT CONTRACTORS INFROMATION ON ALL SHEETS TELEPHONE CALL LUIS URIBE 11/19/2015 11/19/2015 ALONG WITH A SIGNATURE. ALSO NEED SITE SPECIFIV STRUCTURAL CALCS. DOUG SAID HE WAS GOING TO WORK ON THIS RIGHT AWAY AND SEND ME THE REVISED PLANS. CONDITIONS Printed: Monday, November 30, 2015 2:43:18 PM 1 of 3 , SYSTEtitS Printed: Monday, November 30, 2015 2:43:18 PM 2 of'3 SYSTEMS FINANCIAL CONTACTS DESCRIPTION NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT. ECKLUND CONSTRUCTION 117 ARREZO CT PALM DESERT CA 92211 CONTRACTOR ECKLUND CONSTRUCTION 117 ARREZO CT PALM DESERT CA 92211 OWNER JACLIN C SMITH 80871 VISTA LAZO LA QUINTA CA 922S3 Printed: Monday, November 30, 2015 2:43:18 PM 2 of'3 SYSTEMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK.# METHOD PAID BY CLTD . BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $2,00 $0.00 BSA: PV SYSTEM -ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC PV SYSTEM - MISC 101-0000-42403 0 $48.34 $0.00 EQUIPMENT PV SYSTEM - MISC 101-0000-42600 0 $48.34 $0.00 EQUIPMENT PC Total Paid for ELECTRICAL: $145.02 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: 00 Printed: Monday, November 30, 2015 2:43:18 PM 2 of'3 SYSTEMS Permit Details PERMIT NUMBER City of La Quinta BSOL�20T5'8 _REVIEW'TYPE_— —REVIEWER— -SENT'DATE- —DUE'DATE—DATE �STATUS""� '" —REMARKS— NOTES NON-STRUCTURAL - LUIS URIBE 11/2/2015 11/9/2015 11/10/2015 REVISIONS REQUIRED SEE ATTACHED CORRECTIONS LIST 1 WK I NEED THE CORRECT CONTRACTORS 2ND BLDG NS (1 LUIS URIBE 11/16/2015 11/23/2015 11/19/2015 REVISIONS REQUIRED INFROMATION ON ALL SHEETS ALONG WITH A WK) SIGNATURE. ALSO NEED SITE SPECIFIC STRUCTURAL CALCS. WILL BRING IN AN ASSESSORS SET OF PLANS. 3RD BLDG NS (1 WK) LUIS URIBE 11/25/2015 12/4/2015 11/25/2015 APPROVED- WILL FIX ADRESS AT COUNTER ON ALL PAGES TO CONDITIONS 80-871 VISTA LAZO. ALSO NEED LOAD CALCS Printed: Monday, November 30, 2015 2:43:18 PM 3 of 3 C SYS 7Eti1S Bin City of La Quinta Building &T Safety Division Calle Tampico 'f� C7 La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit #7B-495 3 Project Address:�b 171 c2 l Owner's Name: A. P. Number: Address: 10S 2 - Legal Description: Legal City, ST, Zip: VUt� Contractor: o. C l _ Telephone: e one: P Address: 1 � f, 6 1 Project Description: City, ST, Zip: 1 6,"S e f Ca 9 a� >> V11 Telephone: �^ c9 q D. /W C7 State Lic. # : City Lic. #; 0122U Arch., Engr., Designer: 3 Address: City., ST, Zip: Telephone: e one: P 421, <� u c Construction T e: O cc an s YP P Y State Lic. air De mo New Addn Alter Repair Project hP (circle oneNe Name of Contact Person:® G yr Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: 6 L��O APPLICANT: DO NOT WRITE BELOW THIS LINE t/ Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted 'Item Amount Structural Cafes. Revictived, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Cafes. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2". Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up a S.M.I. H.Q.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees lf*f 4 4 Q" COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) DATE: 11-10-15 STATUS: FIRST REVIEW PLAN CHECKED BY: LUIS URIBE TELEPHONE NUMBER: (760) 777-7015 ADDRESS: 80-871 Vista Lazo DESCRIPTION: PV SOLAR SYSTEM APPLICANT: Ecklund Construction PLAN CHECK #: BSOL2015-0218 This submittal has been checked for compliance with the 2013 California Building Codes and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1- SOLAR (REDLINED) PLAN 2- UNMARKED PLAN SET 1- CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: I- SOLAR (REDLINED) PLAN 1- CORRECTION LIST w/responses 2- REVISED PLAN SETS 1- ASSESSORS SITENLOOR PLAN 2 STRUCTURAL CALCS i A, INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 1 of 2 �ECTION A - GENERAL 1) Provide on each.sh'� a o_f resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number --and If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code'5536. Resubmittals will not be accepted with signatures missing. Also change contractor information on each sheet of plans to show appropriate information. SECTION B — SOLAR VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts 1) The output of a utility -interactive inverter shall be permitted to be connected to the load side of the service disconnecting means of the other source at any distribution equipment on premises. Where distribution equipment including switchboards and panelboards are fed simultaneously by a primary source of electricity and one or more utility -interactive inverts, and where this distribution equipment is capable of supplying multiple branch circuits or feeders or both, the interconnection provisions of CEC Section 705.12(D)(1) through (D)(7) shall apply. If de -rating is required, please provide load calculation for the entire dwelling complying with the provisions of Article 220. SECTION D - STRUCTURAL 1) Structural calculations are required for the following: Site Specific structural calcs required for ground mount system. SECTION E - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List (SOLAR) Page 2 of 2 IO/Z612,015 15:40 509-921-5887- ORCHARD CREST i SOUTH VALLEY GROUP, INC/LION -GATE HOA C/o J & W N(auagement PO BOX 1398 Palm Desert, CA 92261 PAGE 81/01 OCTOBER 1, 2015 RE: 80871 Vista Lazo (lot 10) Jacliun C. Smith 222 S. Evergmen Spokane Valley, WA - . Acer IVL: 3muitb, Please be advised the ,A,rchiteatu al Review Commiittee.of �e Lions Date Homeowners Association has approved Your plans for installing solar panels below the fencelwali at 80871 Vista Lazo La Quints, CA 92253. This approval should not be Considered a building permit. Aj1 Reoeary approvals and permits must be obtained from, the City of La Quinta Building & Safety Depa�ent before any contraction begins. All rules and regulations pertaining to corustructioin must be'adhered to during course of construction. i 1f you have any. questions rlwr ding this matter please do nod hesitate to ooatact me at 760-568-0349. Sissel Jensen for Jim McPherson J.dt.W Mattagememt � . I Ko"00TASd1l> 3IiL9P►1 LIGHTING CIRCUIT LOAD 2500 FLOOR AREA AT 3 WATTS PER FOOT 7,500 2 ------------APPLIANCE CIRCUITS AT 1500 WATTS EACH 3,000 0------------ RANGE AT NAMEPLATE RATING 0 0------------ OVEN AT NAMEPLATE RATING 0 1------=------ REFIGERATOR 1,680 0---------- FREEZER 0 0------------ DISHWASHER 0 1------------ DISPOSAL 1,440 0-------- BAR ICE MACHINE 360 0----------- BAR FRIG 0 1------------ I NSTA HOT 1,680 0----------- MIXER 0 0---------- TRASH COMPACTOR 0 0------------- WARMING DRAWER 0 1---------- HOOD 960 0---------- SPA TUB 0 0----------- ELEVATOR 0 2------------- LAUNDRY CIRCUITS 3,000 1 - MICROWAVE 1,440 0----------- WINE COOLER 0 0----------- DRYER CIRCUITS 0 0---------- POOL EQUIPMENT 0 1--------- LANDSCAPE LIGHTING 300 1 -------------SWAMP COOLER 960 TOTAL WATTAGE OF OTHER FIXED APPLIANCES IF 4 OR MORE COMPUTE AT 75% OF TOTAL 0 ------------AT 1500 WATTS EACH 0 TOTAL LOAD 22,320 COMPUTE FIRST 10,000 AT 100% 10,000 COMPUTEREMAINDER AT -40% 4,928 EICEINJ ED AIR CONDITIONING & HEATING LOAD 2015 0------------- UNITS @ 7,920 WATTS 0 NOV 1 g 2------------ UNIT @ 6,240 WATTS 12,480 6 Lk 8,736 CITY of, �PMENTO---- IMMUNITY ---- -- UNIT @ 5,280 WATTS 4-- F.A.U. @ 840 WATTS EACH 0 3,360 0- -- Well ADJUSTED LOAD 39,504 NET LOAD = 39,504 / 240 VOLT 165 175 AMP MAIN BREAKER CANYON ELECTRIC INC. NOTE IS A 400 AMP SPLIT -LOAD PANEL THE 68290 DESCANSO CIRC. OTHER HALF OF HOUSE IS BEING FED BY THE SEC( CATHEDRAL CITY, CA 92234 760-327-6416 LIC. #816081 I WIND UPLIFT CALCULATION: TRIBUTARY AREA OF EA. SUPPORT POST = 52 SF. (WIDTH of PANELS X POST SPACING) ((13' x 8')/2) = 52 SF. qZ (ASD) . = 14.41 PSF. UPLIFT = 14.41 PSF X 52 SF. = 749.3# CONCRETE WEIGHT: W = 150 pcf * (pi (16/2)T2) * (48/12) = 796# THE WEIGHT of THE CONCRETE IS GREATER THAN THE UPLIFT, THEREFORE 16'Dia. x 48'' DEEP CONCRETE PIERS are ADEQUATE. Page No. of Pages Date: JHA Job Name: Morley James G. McIntosh Calculation By. J. MAC Architecture and Engineering Checked By. I WIND UPLIFT CALCULATION: TRIBUTARY AREA OF EA. SUPPORT POST = 52 SF. (WIDTH of PANELS X POST SPACING) ((13' x 8')/2) = 52 SF. qZ (ASD) . = 14.41 PSF. UPLIFT = 14.41 PSF X 52 SF. = 749.3# CONCRETE WEIGHT: W = 150 pcf * (pi (16/2)T2) * (48/12) = 796# THE WEIGHT of THE CONCRETE IS GREATER THAN THE UPLIFT, THEREFORE 16'Dia. x 48'' DEEP CONCRETE PIERS are ADEQUATE. JMA Architecture Project Title: Engineer: Project ID: 73-995 EI Paseo, Suite 201 Project Descr: PALM DESERT, CA 92260 T. (760) 346-6155 ASCE 7-10 Wind Forces, Chapter 27, Part I Description : SMITH RESIDENCE - SOLAR PANEL CAISSON FOUNDATION WIND LOAD ENERCALC, INC. Basic Values Ri Risk Category 1 per ASCE 7-10 Table 1.5.1 Horizontal Dim. in North-South Direction (B or L) = V: Basic Wind Speed 100.0 Horizontal Dim. in East-West Direction (B or L) = Kd : Directionality Factor 0.850 per ASCE 7-10 Table 26.6-1 h: Mean Roof height = Exposure Category per ASCE 7-10 Section 26.7 Topographic Factor per ASCE 7-10 Sec 26.8 & Figure 26.8-1 North : Exposure C East: Exposure C North: K1 = K2 = K3 = South : Exposure C West: Exposure C South : K1 = K2 = K3 = East: K1 = K2 = K3 = Building Period & Flexibility Category West: K1 = K2 = K3 = User has specified the building frequency is >=1 Hz, therefore considered RIGID for both North-South and East-West directions. Buildina Story D hi Story Ht ER :X ER : X Level Description ft ft - ft ft Gust Factor For wind coming from direction indicated North = 0.850 South - 0.850 East = 0.850 West = 0.850 Enclosure Check if Building Qualifies as "Open" North Wall S.¢UIhJr5fa EastWalWest Wall Agross ft"2 ftA2 ftA2 W2 Aopenings ft12 ftA2 ftA2 ftA2 Aopenings >= 0.8Agnes ? Yes . Yes Yes Yes All four Dross values must be non -zero North Elevation : Determine Enclosure Classification per ASCE Section 26.10 1.19, Ver.6.15.1.19 33.0 ft 12.917 ft 10.0 ft KA = 1.000 Kzt = 1.000 KA = 1.000 Kzt = 1.000 &9f IstBi ftA2 0.0 V2 ftA2 0.0 KA2 Building qualifies as "0 eta" Reference area = smaller of 4 sq. ft. or 1% of Agross = 0.0 ft"2 Is Ao > 1.10' Aoi ? _ Aoi = Ao-total - Ao = 0.0 V2 Is Ao > Reference Area ? _ Agi = Ag -total - Ag = '0.0 ft"2 Is Aoi 1 Agi >= 0.20 ? _ Aoi / Agi = 0.0 Building is "Enclosed" when the North wall receives positive external pressure South Elevation : Determine Enclosure Classification per ASCE Section 26.10 Reference area = smaller of 4 sq. ft. or 1% of Agross = 0.0 ftA2 Is Ao > 1.10' Aoi ? _ Aoi = Ao-total - Ao, = 0.0 ftA2 Is Ao > Reference Area ? _ Agi = Ag -total - Ag = 0.0 ftA2 Is Aoi / Agi >= 0.20 ? _ Aoi / Agi = 0.0 Building is "Enclosed" when the South wall receives positive externa! pressure East Elevation : Determine Enclosure Classification per ASCE Section 26.10 Reference area = smaller of 4 sq. ft. or 1% of Agross = 0.0 ftA2 Is Ao > 1.10' Aoi ? _ Aoi = Ao-total - Ao = 0.0 ftA2 Is Ao > Reference Area ? _ Agi = Ag4otal - Ag = 0.0 ftA2 Is Aoi / Agi >= 0.20 ? _ Aoi / Agi = 0.0 Building is "Enclosed" when the East wall receives positive external pressure No No Yes No No Yes No No Yes JMAArchltecwre 73-995 EI Paseo, Sufte 201 PALM DESERT, CA 92260 T. (760) 346-6155 ASCE 7-10 Wind Forces, Chapter 27, Part i Description: SKM RESIDENCE -SOLAR Project Title: En (neer. Prosect Desa Nc. Project ID: West Elevation : Determine Enclosure Classification mer ASCE Section 26.10 Reference area = smaller of 4 sq. ft or I% of Agross = 0.0 fIA2 Is Ao > 1.10' Aoi ? = No Aoi = Ao-total - Ao = 0.0 ft"2 Is Ao > Reference Area 7 = No Agi = Ag -total - Ag = 0,0 ftA2 Is Ao! 1 Agi >= 0.20 ? = Yes Aoi ! Agi = 0.0 Building is "Enclosed" when the West wall receives positive external pressure Velocily Pressures When the following walls experience leeward or sidewall pressures, the value of Kh shall be (per Table 27.3-1) : North Wall = 0.8489 Psf South Wall = 0.8489 Psf East Wall = 0.8489psf West Wall = 0.8489 Psf When the following walls experience leeward or sidewall pressures, the value of qh shall be (per Table 27.3-1) : North Wall = 18.472 psf South Wall = 18.472 Psf East Wall = 18.472psf West Wap = 18.472 psf qz : Windward Wall Velocity Pressures at various heights per Eq. 27.3-1 North Elevation South Elevation East Elevation West Eteva'`art Height Above Base (A) Kz Qz Kz qz Kz qz Kz az 0.00 0.849 18.47 0.849 18.47 0.849 18.47 0.$49 31).47 3.00 0.849 18.47 0.849 18.47 0.849 18.47 0.84? 18.47 6.00 0.849 18.47 0.849 18.47 0.849 18.47 0.k. 48.47 9.00 0.849 18.47 0.849 18.47 0.849 18.47 0.849 18,47 Pressure Coefficients GCpi Values when elevation receives positive external. pressure GCpi : Internal pressure coefficient, per sec. 26.11 and Table 26.11-1 North South East West +l- 0.0 +1- 0.0 +l- 0.0 +1- 0.0 Specify Cp Values from Figure 27.4-1 for Windward, Leeward & Side Walls Cp Values when elevation receives positive external pressure North South East West Windward Wall 0.80 0.80 -1.50 -1.50 Leeward Wap -1.60 -1.60 Side Walls -0.70 -0.70 -0.70 -0.70 qZ (ASO) a6*to3*18.47 = 14.41 PSF PAGE 2 1.19 GENERAL NOTES: 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. 2. NO SHEET METAL OR TECH SCREWS SHALL BE USED TO GROUND DISCONNECT ENCLOSURE WITH TIN-PLATED ALUMINUM LUGS; PROPER GROUNDING/GROUND BAR KITS SHOULD BE USED. 3. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WITH RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS.(CEC 314.15A). A. BACK -FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. 5. ALL CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 6. SMOKE ALARMS AND CARBON MONOXIDE ALARMS MUST BE INSTALLED PER THE 2010 CALIFORNIA RESIDENTIAL CODE AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL PER CRC 8314 & R315 7. ALL WORK TO COMPLY WITH 2013 CALIFORNIA BUILDING CODE; 2013 ELECTRICAL CODE CEC - ARTICLE 705.12, ALL MANUFACTURE'S LISTING AND INSTALLATION INSTRUCTIONS. 8. GROUND MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED IN ACCORDANCE WITH UL1703 SECTION R902.4 (CRC) & 1509.7.4 (CBC) 9. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECtRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 10. ALL CONDUITS AND EQUIPMENT SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND MATERIAL COLOR OF THEIR LOCATION. 11. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE -PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM. (CEC 250.97). 12. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR ` UNLESS OTHERWISE NOTED OR STANDARDIZED. 13. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 14. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND N SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 15. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. 16. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. ( _ 17. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. 18. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. 19. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIRE^ISNTS-B*4`3E „l ;�E 6QGA_ ^." ' TT' SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53, 690.35(F), 690.54, 690.64(B)(7) AND 705.10 20. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. 21. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. t� f a747A SHEET INDEX PV -P1 - Cover Sheet P6 - Inverter Sheet P2 - Plot Plan P7 - Rails P3 - Three Line P7A- Fire Rating Rails P4 - Structural View P8 - Attachments P5 - Module Sheet P9 - Grounding PSA- Fire Rating Sheet P10 - Warning Labels P11- Placard F Prepared by (AN: www.solatperrnhservices.com intoQsolarpermitserwces.com Solar Permit Services, inc. 949.872-8236 VICINITY MAP .,,.... AP°oNs-cRv°T1ON . FO I �5 r DATE ra: s Fti; r� CANADIAN SOLAR - CS6P-260M & SOLAREDGE - SE6000 A -US b8TED BY UNDERWRITER'S LABORATORIES FOR ELECTRICAL AND FIRE SAFETY (CLASS A FIRE RATING) 1) NOTE: NO DISCHARGE OF ANY POLLUTANTS TO ANY STORM DRAIN SYSTEM. 2) UL 1703 FOR MODULES & UL 1741 FOR INVERTERS PER CITY SOLAR REQUIRMENTS. 2013 CEC, 2011 NEC, CITYICOUNTY FD -MARKINGS, LABELS, AND WARNING SIGNS REQUIRED DISCLAIMER: If any Errors, Disaepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S PV -P1 ARRAY - 48 MODULES oma, COVER SHEET z o ARRAY TILT =10° p N I ARRAY AZIMUTH = 270° w x N GROUND MOUNT _w C i W i _ O C) U U I Uo z zm I I v�N �( to J W J Cn D x W Y c` o c~vnaU c� SiM w IUQ= .w ooQ iwf-a.a :°o < I Y Y Y ECKWND U W N corno UNGROUNDED INVERTER1 � C! a POSITIVE GROUNDED INVERTER ❑ N N N to to co W NEGATIVE GROUNDED INVERTER -� 1 0 _� o WWF w o w a.( 0 z, W ENPHASE MICROINVERTERS rvnii O }aa x N THIS PROJECT SHALL COMPLY WITH THE o X013 CA BUILDING CODE ? W 2013 CA PLUMBING CODE0 M LO 2E 2013 CA RESIDENTIAL CODE v C4 W m M CC 2013 CA ENERGY CODE >- Q u u 013 CA MECHANICAL CODE w � W J z< Q •2013 CA FIRE CODE w = 0 o 2013 CA ELECTRICAL CODE - 2011 NEC °o a. N > o go ORDINANCES OF THE CITY OF LA QUINT' W — a CANADIAN SOLAR - CS6P-260M & SOLAREDGE - SE6000 A -US b8TED BY UNDERWRITER'S LABORATORIES FOR ELECTRICAL AND FIRE SAFETY (CLASS A FIRE RATING) 1) NOTE: NO DISCHARGE OF ANY POLLUTANTS TO ANY STORM DRAIN SYSTEM. 2) UL 1703 FOR MODULES & UL 1741 FOR INVERTERS PER CITY SOLAR REQUIRMENTS. 2013 CEC, 2011 NEC, CITYICOUNTY FD -MARKINGS, LABELS, AND WARNING SIGNS REQUIRED DISCLAIMER: If any Errors, Disaepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. CONSTRUCTION W oma, z o p N I i M iI a x N O _w C i W i _ O C) U U I Uo z zm I I v�N � J W J Cn D x W Y z Y tl- ti c� SiM w IUQ= � ,'n I iwf-a.a :°o < I ECKWND CONSTRUCTION N CANADIAN SOLAR - CS6P-260M 38.7' x 64.5' 18.7" NOTES: -WORKING CLEARANCE FOR MAIN SERVICE PANEL AND AC DISCONNECT EXCEEDS 3' -2013 CALIFORNIA ELECTRICAL CODE [2013 CEC) - ARTICLE 690, ALL MANUFACTURES' LISTING AND INSTALLATION INSTRUCTIONS. -PV EQUIPMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. (NEC 690.4 E) -PHOTOVOLTAIC SYSTEM CONDUTORS SHALL BE IDENTIFIED AND GROUPED. THE — MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING,MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. (NEC 690.4 B) N.T.S CL 4 N 241'-2" P/L 0 LAROUND ARRAY :ES GROUND MOUNT ARRAY 48 MODULES ARRAY TILT @ 10' ARRAY AZIMUTH @ 270° (E) PULL BOX ("J" BOX) i i i ) 270' TRENCH 18' UNDERGROUND 1/2" PVC SCH. 40 3't EXISTING WALL J- BOX UNDER ARRAY / SEALED TIGHT NON-FUSED - NEMA TYPE3 MIN. (TYP) �' 10' TRENCH 18" UNDERGROUND , 1-1/2" PVC SCH.40 -Ez NVERTERS- (N) 2 INVERTERS - V) O04 1 SOLAR EDGE-SE600OA-US-240V SOLAREDGE-SE6000A-US-240V O U MOUNTED TO WALL I (N) t00A 240V PV IVa Nm O V SUB PANEL 1/32" = 1'-0" PV -P2 PLOT PLAN B g O N j LL ' co g U.J U) zw gx 0 U LU ce 0 O!� '_; z_ OTO714 ;IT1( OF LA QUINTA DEPT. BUILDING &' ®vE® LU D�Cp� TRU (TION 0 - FOB F Off& -0 BY SCALE: 1/3211=1 1-011 DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the C or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will beheld responsible to the result•of.any errors, discrepancies or omissions and the cost of rectifying them. UUU SF_ U O D Q Y�Y Go a) 0 t7 M r N r N_ N_ N_ U) U) Cl) 222 W W W V) U) U) I-' z D x O g LO Z W D M DL xgN C7W CDM o}OQ� N�UV w3:gQ�Q =�On» t: 0;00) jClU cgnC14a�0 :�0 W om zo ON r V) O04 1 O U I W IVa Nm O V � � of NOWo ON W U) W U C'M �QgZ lLLLL1Jll Zj0 FLO Y _3O ti W (L CL X o i5 ECKLUND CONSTRUCTION ELECTRICAL NOTES: E1. ALL EQUIPMENT IS LISTED FOR USE. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 60OVDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. E7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM (SOLAR EDGE INVERTERS 50OVDC RATED MINIMUM). E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E11. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E12. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E13. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL THAT ARE CONNECTED AS AN EXPANSION SPLICE. TO 17f1LffY GRID 120rz40V SINGLE PHASE BI-DIRECTIONAL UnUTY METER I 200A x 120% = 240A 240A -175A = 65A 65A >- 65A PV -CB NOT CENTER FED PANEL MOUNTS AND EQUIPMENT (N) 65A 2 POLE BREAKER & AC DISCONNECT SHALL BE INSTALLED AT OPPOSITE END OF MAIN CIRCUIT BREAKER r� I I I I I I I ------ ----J L--- 2' -1-1/2" EMT AC CONDUIT (3)#1 CU THWN-2 CONDUCTORS E14. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E15. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E16. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. E19. ALL MODULES AND RACKING SHALL BE GROUNDED USING UL 2703 LISTED RAIL INTEGRATED GROUNDING SYSTEM, OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS OR WEEBS. 2 STRING OF 12 PANELS 2 STRING OF 12 PANELS F@ ■ IN SERIES & PARALLEL IN SERIES & PARALLEL P300 - POWER OPTIMIZER r - - , - - - _i -i DC UNDER EACH MODULEDC- DC IDC ' - I I / - Dc. -- ---� I �. GROUND WIRE BARE --Fo�IUN Dc-NEC 250 (TYP) �(4) #10 CU PV -WIRE NEC 300.6 C1GROUNDED ) UNGROUNDED J- BOX ON ROOF SEALED TIGHT -- -VERTER #2 ' J -BOX INVERTER #1 NON-FUSED -NEMA TYPES MIN.LAR EDGE SOLAR EDGE l SE6000 A -US -U 240V I SE6D00 A-US4 1240V I MAX. EFFIC. 97.5% MAX. EFFIC. 97.5% jEGC 15' EXTERIOR 314"EMT DC CONDUIT - ��`� (4)#10 CU THWN-2 CONDUCTORS I t1A �P IIA `L (1)# 8 CU THWN-2 GROUND 90°C WET & DRY IDCOISCONNM cmurm � ADJACENT TO MSP (N) 1 ODA 240V AC DISCONNECT NON -FUSIBLE 2POLE,LOCKABLE KNIFE BLADE,NEMA 3R 6.3 & NEC690.17 AIC RATING OF L2-35A 00A 240V PV 22,000A PANEL 2POLE BREAKERS EXISTINGPULL BOX ("J" BOX)T, 270' TRENCH 18" UNDERGROUND 1-1/2" PVC SCH. 40 AC CONDUIT QUINTA CITY `,BUILDIN FETY DEPT. AP -PROVED II ----J 3M" EMT AC CONDO DffiN1OCUTHWN-LGDW {t 90°C WET & DRY ENCLOSURES GROUNDED l (1)96 CU THWN-2 GROUND (3)#CU THW1` -2 CONDUCTORS TO MAIN PANEL GROUND 90°C WET & DRY (1)#6 CU THWN-2 GROUND CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: (E) LIFER GND 90°C WET & DRY AC REQUIRED CONDUCTOR AMPACITY 35+35=70A AWG # 1 DERATED AMPACITY: (130) (0.91) (1) =118.3 A 118 3 A > 80 A THEREFORE AC WIRE SIZE IS VALID MAIN ELECTRICAL PANEL (E) 400AMP 120/240V (E) 200A & (N) 175A MCB I43..J T•• ARRAY RATING I7 ' r t MAIN PANEL PV -CB SIZE= 65A L �J { �� 1 48 ' 237.3 " 0.975 /1000 = 11.106 KW -AC (CEC) ISC: 8.99 ADC Input voltage 365/12 = 30.42 Vdc modules per string Total 6240/365V = 17.10 INVERTER INVERTER AC MAX OUTPUT CURRENT IS: 25.1.25.31.25A x 2- 62.5A 48 ' 237.3 ! 1000 = 11.390 KW -DC (PTC) ml INVERTER DC MAX INPUT VOLTAGE = 500 V/DC T`• 75A MCB MOUNTS AND EQUIPMENT (N) 65A 2 POLE BREAKER & AC DISCONNECT SHALL BE INSTALLED AT OPPOSITE END OF MAIN CIRCUIT BREAKER r� I I I I I I I ------ ----J L--- 2' -1-1/2" EMT AC CONDUIT (3)#1 CU THWN-2 CONDUCTORS E14. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E15. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E16. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. E19. ALL MODULES AND RACKING SHALL BE GROUNDED USING UL 2703 LISTED RAIL INTEGRATED GROUNDING SYSTEM, OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS OR WEEBS. 2 STRING OF 12 PANELS 2 STRING OF 12 PANELS F@ ■ IN SERIES & PARALLEL IN SERIES & PARALLEL P300 - POWER OPTIMIZER r - - , - - - _i -i DC UNDER EACH MODULEDC- DC IDC ' - I I / - Dc. -- ---� I �. GROUND WIRE BARE --Fo�IUN Dc-NEC 250 (TYP) �(4) #10 CU PV -WIRE NEC 300.6 C1GROUNDED ) UNGROUNDED J- BOX ON ROOF SEALED TIGHT -- -VERTER #2 ' J -BOX INVERTER #1 NON-FUSED -NEMA TYPES MIN.LAR EDGE SOLAR EDGE l SE6000 A -US -U 240V I SE6D00 A-US4 1240V I MAX. EFFIC. 97.5% MAX. EFFIC. 97.5% jEGC 15' EXTERIOR 314"EMT DC CONDUIT - ��`� (4)#10 CU THWN-2 CONDUCTORS I t1A �P IIA `L (1)# 8 CU THWN-2 GROUND 90°C WET & DRY IDCOISCONNM cmurm � ADJACENT TO MSP (N) 1 ODA 240V AC DISCONNECT NON -FUSIBLE 2POLE,LOCKABLE KNIFE BLADE,NEMA 3R 6.3 & NEC690.17 AIC RATING OF L2-35A 00A 240V PV 22,000A PANEL 2POLE BREAKERS EXISTINGPULL BOX ("J" BOX)T, 270' TRENCH 18" UNDERGROUND 1-1/2" PVC SCH. 40 AC CONDUIT QUINTA CITY `,BUILDIN FETY DEPT. AP -PROVED II ----J 3M" EMT AC CONDO DffiN1OCUTHWN-LGDW {t 90°C WET & DRY ENCLOSURES GROUNDED l (1)96 CU THWN-2 GROUND (3)#CU THW1` -2 CONDUCTORS TO MAIN PANEL GROUND 90°C WET & DRY (1)#6 CU THWN-2 GROUND CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: (E) LIFER GND 90°C WET & DRY AC REQUIRED CONDUCTOR AMPACITY 35+35=70A AWG # 1 DERATED AMPACITY: (130) (0.91) (1) =118.3 A 118 3 A > 80 A THEREFORE AC WIRE SIZE IS VALID CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: DC REQUIRED CONDUCTOR AMPACITY [NEC 6902(8)(1)1: 8.99' 1.25' 115 =14.05 A AWG 910, DERATED AMPACITY: (40) (0.58) (0.8) = 18.56 A 18,56 A > 14.05 A , THEREFORE DC WIRE SIZE IS VALID. LAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of. rectifying them. N.T.S I PV -P3 I THREE LINE ELECTRICAL I 2 0 to U) a? cc g coo �w W �0 w �0 U� vn 0 Ow pippp �t N FU -►U -w (v a U COQ YY� aoorno � M r N r- .- N N N (DcoU) www U)Cn0) N 0) O �Uo U N Owm niVWr� D Ir n W J Q Z Y _3O U Q = W aa W 0 9 Zs 0 Xa 0 W U w� W rn Lu 000 U M J `W WL0 ECKLUND CONSTRUCTION'l RATING IS:237.3W.8(A)(1),(B)(1) ARRAY RATING I7 each ISC = 8.99.1.25.1.25=14.05A CEC 690PTC INVERTER DC MAX INPUT CURRENT = 23A VOC = 37.8 ' 1.13 = 42.71 V/DC MAIN PANEL PV -CB SIZE= 65A 48 ' 237.3 " 0.975 /1000 = 11.106 KW -AC (CEC) ISC: 8.99 ADC Input voltage 365/12 = 30.42 Vdc modules per string Total 6240/365V = 17.10 INVERTER INVERTER AC MAX OUTPUT CURRENT IS: 25.1.25.31.25A x 2- 62.5A 48 ' 237.3 ! 1000 = 11.390 KW -DC (PTC) IMP: 8.48 ADC INVERTER DC MAX INPUT VOLTAGE = 500 V/DC CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: DC REQUIRED CONDUCTOR AMPACITY [NEC 6902(8)(1)1: 8.99' 1.25' 115 =14.05 A AWG 910, DERATED AMPACITY: (40) (0.58) (0.8) = 18.56 A 18,56 A > 14.05 A , THEREFORE DC WIRE SIZE IS VALID. LAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of. rectifying them. N.T.S I PV -P3 I THREE LINE ELECTRICAL I 2 0 to U) a? cc g coo �w W �0 w �0 U� vn 0 Ow pippp �t N FU -►U -w (v a U COQ YY� aoorno � M r N r- .- N N N (DcoU) www U)Cn0) N 0) O �Uo U N Owm niVWr� D Ir n W J Q Z Y _3O U Q = W aa W 0 9 Zs 0 Xa 0 W U w� W rn Lu 000 U M J `W WL0 ECKLUND CONSTRUCTION'l Key Features • High module efficiency up to 16.16% • Positive power tolerance: 0-+5W • Robust frame to up to 5400 Pa load • Serf -cleaning surface • Outstanding performance -at low irradiance • High:energy yield at Low NOCT • Backed By Our New 4012S Unear Power Warranty Plus our added 26 year insurance coverage 1 � ...tiAdded balva From Warrltn 777te .,'. 777.4 yr -S y ox 5 10 1s 20 25 eir CanadianSdar • 10 year product warranty on materials and workmanship • 25 year linear power output warranty, CS6P is a robust solar module with 60 solar cells. These modules can be used for on -grid solar applications. Our meticulous design and production techniques ensurea high -yield, tong -term performance for every module produced. Our rigorous quality control and in-house testing facilities guarantee Canadian Solar's modules meet the highest quality standards possible. Best Quality % 235 quality control points in module production • EL screening to eliminate product defects • Current binning to Improve system performance • Accredited Saltmist/Ammonia resistance Best Warranty Insurance • 25 years worldwide coverage • 100% warranty term coverage • Providing third party bankruptcy rights • Non -cancellable • Immediate coverage • Insured by 3 world top insurance companies Comprehensive Certificates • IEC 61215, IEC 61730, 1 EC61701 ED2, UL1703, IEC62716, CEC Listed, CE and MCS • lS09D01 :2008: Quality Management System • ISO/TS 16949:2009: The automotive quality management system • IS014001:2004: Standards for Environmental management system • QC080000 HSPM: The Certification for Hazardous Substances Regulations • OHSAS 18001:2007: International standards for occupational health and safety G4 WAOF A CFR CS 6P-244i245/256t2.55f26Q M Electrical Mata 3TC ! C88P-2. BBP-tii5kt�CS8P�50 fP-SSS G_S9P�Z NaminalMazlmum.Powot (Pmaxi 240W 245w 250w 255w 260w l 2p6mum2porstl9g,V0lt a Vmp 0tlmumOparaengcurrent{Imp Open Clrcult Voltage oc) 30,2V 90.311 t 30AV _ 30_5V TOM 8.09A 822A 6:35A 87,3V 37.4V l 37,5V 37.'7V 30�N &4 37.8V ! Short Circuit Current (Ise) SAGA 8.61A 8.74A 8.74A 8,99A Module EOiciency OperatIngTempereture_ 14.8296 15;23% 15,54% 16.85% .40+C-+l#S`C 1818% m i MaAmuSystemVoltage OptimuntOperating Current(ImD) Maximum Series Fuse hating 15A Appllcation Ctassirtcation Clasa A I Power Tolerance 0-+Sw Under StarAwdTestCondnims (STC) d irraftnce d lOOW)m', spedmmAM 1.5 andcea temperetwe ar25V I Temperature cnaracteristfcs t - PmezI-ois%ft -0.4S%FC j �TemperatuteCoeH)Went 'V -0c do 0.060 ftffmat Operatirlg Cell Tsmpersture 45t2'C -), i_.__.��.__ , Performance at Lour irradiance 1 Industry leading performance st low irradiation i environment,<95.6%moduleefficiency froman Irradlancs of 1000w/m'to 200w/m' (AM 1.5, 25 C) NOOT _11:b .. C68i►-24` 56P 24 0111P 26 CSV -255 046P-20 "Nomlnal Maximum Power Pmax 173w 177W 180w _194W 188w i O 9mum0 eratin Voltage 27.6V 27SV 27.1V 27.8V 28.0v OptimuntOperating Current(ImD) 6.29A 6.40A 6.51A 6.62A 6.10A Open Circuit Voltage (Voc) 342H 34.3V 34.4V 34.6V 84.7V r._ ( short circuitcurrent(Isc 8.85A 8,87A 7,08A F.it1A 7.28A UnderNarinY Opandnp Ce1lTeropersfurq trrgdter,eeo1800whn , gpeotnxn AN 1,6. ambfem iempvatuse 20C. +trN speed I mfg Mechanical Data 1 celitype Mono -crystalline 156 x 156mnt 2 or 3ausbars _ � --4 80(6x 10)� -�_ ---- —CellArrartgemant r Dimensions 1638 x 982 x 40mm (64.5 x 38.7 x.1.57in) weigh , Ift (a1.91bs) Front Cover t 3.2mm Tempered glass From Material Anodized alumintum alloy .t-9Ol( ���_-Y—�----- IP66wIP67,3dlodes --- I Cade 4rwnJlEC 12AWG(UL), ib6ornrn I Connectors MC4orMC,lComparebie ( Standard Packaging (Modules per Pallet) 24pcs MOdutePieces per container (40ff. Container) 672pcs(4VHQ) IN Curvets (CS6P-250M) i If_ ._ Bpeedleatbro WAtiled in Mir dstesheet ere subject to lunge W haw Wwac6os. About Canadian Solar Engineering Drawings, Canadian Solar Inc. Is one of the world's largest solar Canadian Solar was founded In Canada In 1001 and was companies. As a loading vorlicofly-Integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In manufacturer of Ingots, wafers, cells, solar modules and November 200t). Canadian Solar has cell manufacturing capacity solar systems, Canadian Solar delivers solar power of 1.SGW and module manufacturing capacity of 2.3GW. products of uncompromising quality to worldwide customers. Canadian Solar's world class team of W professionals works closely with our customers to provide them with solutions for all their solar needs. Iwww.canadionsclar.com �.g.,,s.etuwr� �zotaua.da, soar lnc DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or'omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S PV -P5 MODULESHEETI V N cOo c~i)aU 0 , O W Y Y Y U) C9 gw00(0 v"17 Q � N U N N N ' (Jr) fQ rn W 0 HHH Ow >_>_r U) (n U) N Z � I o � I Z W i a 0 LO 04 W N ` U 1.- 0 M O >- ON U 'U W�Wg�Z �Y5<ZQ W =o0v)>j I O F—�U)5;CYU ! I a -a-g0 W oro Z N 0 P �o N O rno 5 ' o U U) co Ov W I i. 1 J �NW� D at (n I D Ix U M ! wa. ii- Xo ECKLUND CONSTRUCTION tr'§t „cs Am +v� r r Y:y .. -_.. � ..... _ ,.. -. _.. �...v _ ••sem—._' - iNSTALLP o F STARL MODULE! r Canadlan5olar Do not drop or place objects (such as tools) on the modules. Do not carry modules on your head. Do not use sharp instruments on the modules. Part (cular care should be taken to avoid module backsheets being damaged by sharp objects, as scratches may directly affect product safety. r Do not leave modules unsupported or unsecured. Do not change the wiring of bypass diodes. Keep all electrical contacts clean and dry. PRODUCT IDENTIFICATION Each module Is equipped with two identical barcodes (one inside the laminate under the front glass, the second on the rear side of the module) that act as a unique identifier. Each module has a unique serial number containing 13 (pre March 2013) or 14 (post March 2013) digits. A nameplate is also affixed to the rear of each module. This nameplate specifies the model type, as well as the main electrical and safety characteri- stics of the module. 5.© MODULE INSTALLATION PRECAUTIONS MEASURES AND GENERAL SAFETY Prior to installing modules please obtain information about any requirements and necessary approvals for the site, installation and inspection from the relevant autho- rities. SYSTEM FIRE RATING The fire rating of this module is valid only when mounted in the manner specified in the mechani- cal mounting instructions. Canadian Solar Inc. modules have been certified by CSA as Type 1 for fire performance. When installing the modules on rooftop, please en- sure the assembly is mounted over a fire resistant roof covering rated for the application. A photovoltaic systems composed of UL1703 certified modules mounted on a UL2703 certified mounting system should be evaluated in combina- tion with roof coverings in accordance with UL1703 standard, with respect to meeting the same fire classification as the roof assembly. Mounting systems with a System Fire Class Rating (Class A, B or Q. tested in conjunction with fire rated "Type 1" rated modules, are considered ac- ceptable for use with Canadian solar Inc, modules, provides the mounting system does not violate any other requirements of this manual. Any mounting system limitations on inclination or accessories required to maintain a specific System Fire Class Rating should be clearly specified in the installation instructions and UL2703 certification o the mounting system supplier. 00 NOT STAND OR STEP on the modules under any circumstances. Localized heavy loads may cause severe micro -cracks at cell level, which in turn may compromise module reliability. Failure to comply with the above caution will void Canadian Solar Inc 's warranty. DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S PV-P5A I MODULE CERTIFICATION SHEET , C14 (n � �$ ccoovaU UC� O�Q 0 W Y Y 05 O UJIaoorno v ch — CV 85 LLi Lu ui U , N N N U) U) CO LLI W W W o0p Cf) C0C/) V' N W o� Z o 0 �Co Co I CO 1 rno � � I 0 L i Z W V O Cl) a j X N W N 17 rn co o re N Q8p� O U U U W W Z i of I- < W =open» d U 0U) i W o� Z o 0 �Co Co ECKLUND CONSTRUCTION CO 1 rno g V O Zm I o re N Q8p� O wo O U)co o�W� Z �Z w Z III WUM Yr�O 'ZL Ur Q= ZD r `n (L 0- Xo ECKLUND CONSTRUCTION solar =• SalarEdge Single Phase Inverters For North America SE300OA-US / SE380OA-US / SE5000A-US / SE600OA-US ! SE760OA-US / SE1000OA-US / SE1140OA-US O 3 4750 r�� Ingle Phase Inverters for North America 12480 14250 s W .. M)._...............................I SE3000A-US/SE3800A-US/SE5000A- US/ SE6000A-US/ I. 1 ............................. SE760OA-US / SE10000A•US/ SE1140OA-US I C7 W rn CV) ; S£3000A-US 1 Sf3800A-US I $ESOWA US w._ _ SE60DOA US; —_ _ ...1..�_ .. _ .. _ ,_- Sf7600A U5 ; SE10000A US { SE1S400A US .__..-_ _ _ _ __ OUTPUT .. .. 775x315,x172...:.., ....:..T75.x31,5x191......... ........ Max InputVohage..SUO =a0U) ............ . Nominal AC Power Output i 3000 i 3800 5000 M 7600 1 9990 @ 208V { 11:100 I ..(......... VA ou......... t ............. Max. AC Power ! 3300 i.......,....t...? :....... ........... l 5400 @ 208V 4150 saso zaoV . ° 6000 .10800 @ 208V i 8350 12000 11t?9so z4ov VA AC outputVoltage Min: Nom. -Max"' ....:............ t..,...,.... '33 @ 20811 .l . 1...,..;........ ..... ..... , 183.208.229 Vat .,....13 .•{.155.�7,240V 3 18 73 34.5 AC output Voltage Mirt(Nom. htax.n9 1 l I ✓ ✓ 211-240-264 Vac I Reverse•Polarity Pro(e=!i°n.............. ....... ..... Yes. AC Frequency Min..NomrMaz!� 59.3.60 • GOS with Hi countrys .............. 'n8 57.60.60,5) .............,...............,,,,........ .. Hz .,.. , Mex. Continuous output Cwrenr 3 12.5 24 @ 208V 1 16 21 @ z40y.. i 25 r ......... 48 @ 2.08V i 32 ; 47.5 i .42 @ .2C9U...:..... . A GFOIThreshold 98 3 98 3 98 i 98 . A U1iGty MGnitming, ISIarttFin Protection, Country Configurable Thresholds s 97,5 @ 208V 97,5 97.51 yes INPUT ... . 1:% ....... .....!.,,,..,. Recommended Max. OC Powert'i Ic i 3750 3 4750 i 6250 75W 9500 12480 14250 s W .. M)._...............................I ,............. I. 1 ............................. I C7 W rn CV) Transfamer•iess Ungrounded 30.5 x 12.5 x 7 / t 30.5 x 12.5 x 7,5 / i yes fn U U I (HxWgO)...... . ....... .............i .. .. 775x315,x172...:.., ....:..T75.x31,5x191......... ........ Max InputVohage..SUO =a0U) ............ . 24.7 I 9i.2%23i . .. i .. .,J: ` .. lb/kg..54.7 Nom. OC to ut Voha a P......,.$ Natural Convection I .. , 325 @ 268V 350 @ 240V E .. I Vdc .................j.............. .........,.. I 18.5 @ 208V t..,...,.... '33 @ 20811 , hlax.InputCurreMt'1 l .....45 .....1 .,....13 .•{.155.�7,240V 3 18 73 30.5,�Z4t)V..i 34.5 Ad, Max. rt Clrtuit Current 3 :.,....,...<............ W Fwother rtoonal MOW *ase ootten SdirE* uppoM ............. 45 Cs61W and lover: thiW.d to IB% A.,C, paver 7 6kW and by7Mee: LWted tv125i:P.rnxAriontwhem iheyauN aw.r,�s hhxh tmiptrrme Is zMve 7rfi25'C mid Fn135`3 to baocm wAerc itktsdew 77'F/25'C Adc I Reverse•Polarity Pro(e=!i°n.............. ....... ..... Yes. ,� r""Zo traM imwter PM; St+ AAWDONPW Ground -Fault isolation Detection z01� U M I 600k+ 5ensi8v;ty U = III=LLL 1 ................ Ma umum inverter EhSderuy i 97.7 98.2 98 3 98 3 98 98 98 . i ac Wei ted Effidency i 97.5 ....... . 98 97,5 @ 208V 97,5 97.51 97 @ 208V 1 97.5 ... . 1:% ....... .....!.,,,..,. ... < .98�?a40V. i......... ..t..., ... ....,f..9Y.5�6V ... ........ ... p.,. Nei httime Pmarer Consum titin r 2:5 t4 W ADDITIONAL FEATURES Supportedfnmmunitation tnterfaims ! R54 ��.-__._ -___-_._.___---.------•-._-.. 85, RS232, Ethernet Bee (optional) ...........:........ . Revenue Grade Data, ANSI C12.1 i ............................. ........................... Optional"' ........................................................ ................. l Rapld Shutdown -NEC 2014 69012 ........_.,..�,...�......,.._...,..._...._ Functionality enabled when SGkut dge rap;d shutdown kit is iastallecl ...... _ _-_ �. �.. .....�..._._._....,.,....._,.........r.._....o,......... _.••---••- M ......._........ �STANDRROCOMPLtANCE Safety } UL1741, Ui16990, Ut1998 , C5A 22.2... l Grid Conn ettton5tandards , IEEE1547 ............. Emissions_ KCpartlSclass B- AC output conduit sue / AWG range „ ........... .__M4 Wm imum / 166 AWG„ ! 1 .................................... ur minimum / &3 ANUG .......: ...3,.,..,... DC input conduit s ze JN of strlr s J R 3/4” minimum j 1-2 sttings / 16.6 AWG i 3/4" mininWM 11.2 strings / 14.6 AWG ff M a l 1 I C7 W rn CV) Dimensions with Safety Switch 30.5 x 12.5 x 7 / t 30.5 x 12.5 x 7,5 / i 30.5 x 12.5 x 10S 1775 x 315 x 20 fn U U I (HxWgO)...... . ....... .............i .. .. 775x315,x172...:.., ....:..T75.x31,5x191......... w =a0U) Wcigiltwrth5a(etyswitch 24.7 I 9i.2%23i . .. i .. .,J: ` .. lb/kg..54.7 Cooltng Natural Convection I Fans (user replaceablet E Noise ! r 2S ... ......... .... c 50 i ding ,L... Min.,Vlax. operatlng Temperature L.- 1 -23 to +140/ -25 to +60 (•40 to +60 version availabte1c) U i ................ .......... ,,....... ' ........ W W m ... NfMA 3R V�o i.......... W Fwother rtoonal MOW *ase ootten SdirE* uppoM Cs61W and lover: thiW.d to IB% A.,C, paver 7 6kW and by7Mee: LWted tv125i:P.rnxAriontwhem iheyauN aw.r,�s hhxh tmiptrrme Is zMve 7rfi25'C mid Fn135`3 to baocm wAerc itktsdew 77'F/25'C aW reridHYiQY�OtManQA rdFetouur) ' �dR •NhLOd'L7 �^R^I Qf G1 SMILAM • L o OwN (q A h%J,, WnM scow mwbe me¢tlb kwor wO Ran m kipus tnrrese tothe whin rwM. ' ,� r""Zo traM imwter PM; St+ AAWDONPW z01� U M I taiUpidsAutdpivn t%d P(N: SEMOe RSG St U = III=LLL A•erlwnbn P/N: S£.M),usWDW U4 Q w. - aa x N.T.S PV -P6 I INVERTER SHEET I M to (n CV d -Q Quo I—F-W 00 W O D Q r 0 W Y Y Y 0GGoorno M r— Q 111 111 111 U r N N N ' W fA co En WIwX 222 _jt - - H H FW - }}}W . �. Gp� Cl) to V N JECKLUND CONSTRUCTION' DISCLAIMER: If an Eirors, Discre ancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. I 0 I CO LO zW z M a l 1 I C7 W rn CV) o f 0 IIE fn U U I W ?j Z ga a I w =a0U) O �cofn5; X�N>o a U I to -ag0 JECKLUND CONSTRUCTION' DISCLAIMER: If an Eirors, Discre ancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. W � tO O ro I � o a x W 04 OU C, U i Q W W m V�o 0 W I U o OwN o ,� ZWW� it W z01� U M I U = III=LLL 00 to F Q w. - aa x '0 JECKLUND CONSTRUCTION' DISCLAIMER: If an Eirors, Discre ancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. Solara r SolarEdge Power Optimizer Module Add -On For North America OP250-LV / OP300-MV / OP400-MV / OP400-EV + 3. ' ,'kS 5 Y. �S.. R.. <�,,:..z ... . .. -,tea �P� •� �- ._ _ PV power aiptinkati+ort at -.the module -levet Lip to 25% more energy Superior effiuency (994%) - Mitigates all types of module mismatch tosses, from mainufacturingt6leeance to partial fhaditig - Flexible systetri design for maxtftium space utWiization - Next generation maintenance with modute4evel monitoring - Module4evel voltage shutdown for installer and firefighter safety 0 r, Sohl+ � r l ; SolarEdge Power Optimizer Module Add -On for North America OP250-LV / OP300-MV / OP400-MV / OP400-FV _11...—_..___.__.._......_.. I _. ------ LV _ _ ._._ _. _ __.___.._ _ _._- _- _. -LV-_. OP3pQ-MV Ot+4DE}-1VIV _ OP400-EV _._� _ 7WP_111.1._.__ INPUT =3} i I N 1 3FW- rn� Input Rated Input OC Power' 250 .300 400 400 ? W ..... .........,................. Absolute Maximum Input VOILage (Vac) 55 ....1111... ....- � 7S 75 ...125 ,1111. 1111 Vdc DP MT Operating Range ? 5.55 ......... � i 5.75 5.75 15-125 Vdc 1111... .. ,.. ... .. 1111 ... 1111 f - ...........<... Maximum Short Circuit Current (Isc) of connected PV 10 � 1111 .. ....� ... 10 •10 7 AdC Module f. ;.: U ..................................................... . ................ Maximum OC Input Current 12.5 12.5 12.5 8.75 1 Adc Maximum Efficiency ............ . !i..1111.>...........'...'......... 995......, ., ..... 1111. ..........l.. % 1111 Weighted Ef"suenc... .. .. .. ... .. ....e. ........ .....,......... 1111 y 98.$ .......... ... ., .. .. � t ... .. ... Overvoltage Category p; OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current . ................. ......... A...d._.c OperatingOutputVolta a ._. 5_ ;... Vdc__...... DURING STANDBY (POWER opTimraR DISCOfyNECTEO FRONT INVERTER OR INVERTER OFF) _OUTPUT w-111_1-V_I Vdc _...� 1 Safety Output Voltage per Power Optimizer- 1111 _._ z __- STANDARD COMPLIANCE _ WL Fan w CL n=. X _. �, ........ _....�.._...._ __.-... _.. FMC FCC Part15 Class 6, IEC61000.6.2, IEC61000.6=3 . .. .., r.... ,1:111<....< Safety .......... .... ... 1111.. IEC62109 1(class it saety), UL1741 1111. 1111 ,... . Material i ........ UL -94 (S VA) UV Resistant i ROHS ! ._. _ Yes ' .. INSTALLATION SPECIFICATIONS .�....,.._...�...�...„.._...,..,....._...W__...._...__._..._.._•----.--..-•......_.-111_1.._. _.__ 111___1._ . _ _ ._._..�..�....._...�._.._......»... __., _.__..,___ Maximum Allowed System Voltage ... ... .................. 1111. 1000 ; Vdc Dimen$ions (W x L x H) ... . ......... ........ 1111. .. 1111. 143 x 210 x 45 / 5,63 x 8.26 x 1.75 .._. .. .. 1111.. .. . mm/in Weigh[ l ... .. 1111 ... .. .. .. ......... ... .. ........ 45011.0 i r J lb Input Connector ; MC4 J Tyco J H+S / Amphenol- H4 Output Wire Tgpe r .. . . . Double insulated 6rhm'; MC4 ......t..... ... .. I ... ...t.. ... . ... .... Output Wire Length ! 0.95/3.0 r. 111.1 i 0.95/3.0 1.2/3.9 L6 US m/ft Operating Temperature Range -40 • +65 / 40 - +•150 �. C /'F ...1111 ..................... 11;11. Protection hating ? .. ... IP65 / NEMA4 .l ' Relative Humidity , 0..1.00j ..... ........1.1.11. . it • Rasd SIC grdere! tMaoAd�. htomaa of up to •5:,mmr iotvnnce •leaad PV SYSTEM DESIGN USING A SOLAREDGE INVERTER Minimum String length (Power Optimizers) Maximum String Length (Power Optimizers) Maximum Power per_String Parallel Strings of Different Lengths or Orientations SINGLE PHASE THREE PHASE ZM THREE PHASE 480V . 1111, ... 1111. .. .: 1111 ... ., •. , i 25 25 50 t $150 WW 12750 i W Yes. I. . i I I USA • GFRNIANY - 1FALY • FkANCE JAPAN - CHINA - 1SRAL+ . AUSTRALIA wwW.solaredge? us ._�__.__ . _ _- --_ . _ _ -_-_ __ _ . _ ..---_.__ _ ... DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission.In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV -PGA I OPTIMIZER SHEET . 2 R� N � CLo ��w C�o cvno_U W LU 0 Q OW YYY rn 0 co tt W ao rnM � F o Q C4 r _ W W W NNN rn rn rA Cn J w� W W W QO W } } } W W W N ECKLUND CONSTRUCTION I W l H O� Q u7 1 Z W i Z o =3} i I N 1 3FW- rn� O Q i M v I 2 t U 1-- CL W p =o0v)» CD Ci 0 o_ tV > O U cn .- a. r- O 1 ECKLUND CONSTRUCTION W l H O� Z o ON { M 2 t 1 iin (14 OU O O U U v W Nm ~W F- O U N U v i OWo p; z QNz U.1 W a WzWcoo :3 IX YQZ _3O �, WL Fan w CL n=. X o ECKLUND CONSTRUCTION �� IRONRiDGE Ground Mount System S ib—ASucture Top Caps ovio nt On Nil lei rains, is i no„�...I The IronRidge Ground Mount System combines our Standard Rails (XRS) with locally -sourced steel pipes to '” create a cost-effective structure capable of handling any site or terrain challenge. Connect vertical and Installation is simple with only a few structural components and no drilling, welding, or heavy machinery horizontal pipes. required. In addition, the system works with a variety of foundation options, including concrete piers and driven piles. .__•......� �._. RBrl Ass mbly' Rail Connectors Attach Rail Assembly to horizontal pipes. Diagonal: Braces : 144 FAN �b 360° Product Tour Schedule 40 Pipes _ I m Provide additional support Locally -sourced pipes where required. serve as primary structure.. Standard Rails Top -Down Clamps Under Clamps Accessories Rugged Construction r- PE Certified F."4P Engineered steel and aluminum iu, Pre -stamped engineering letters�r * * ' s: available in most states. �-� �`' I components ensure durability_ x ;y,.;, ��. tA,I' Sim ie Assembly Design Software Wire P Y g Curved rails increase Secure modules to rails Alternative clamps for pre- re Clips and End Caps Just a few simple components 1 Online tool generates engineering spanning capabilities. and substructure. attaching modules to rails. provide a finished look. 3 ; and no heavy equipment. EM values and bill of materials. Flexible Architecture xr 24 Year Warranty """:- Design Assistant NABCEP Certified Training � VIN e Multiple foundation and array x Twice the protection offered by �-. .; Go from rough layout to fully $ Earn free continuing education credits, engineered system. For free. white teaming more about our systems. s } configuration options. competitors. f_ Goy to ironriidcga,com,19m to ir�,n. i r .eo�r tra �lc�o IAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the C or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S PV -P7 RAILS SHEET IV 0 N d� do .8 W OW co C9 1 U WCr O; �r N UUU u) a- 6 0 0 co ao01 0 � 0 7 N N N N C0U)(f) 222 rn Cl) Cl) ECKLUND CONSTRUCTION .._ D iz U I Q C3 � �m W iz USN D V) a W N r I O�tOo U'W rn co I 2WW�X+ W � U) zrn JQ2z Q W�W �z UM :i00 w = 5 K 0 O u) W(L(LXo p �00C/55;ab - a O (L U) I W t— I ori zo I ECKLUND CONSTRUCTION O U Q C3 � �m v USN 0 O�tOo z W 2WW�X+ W zrn JQ2z X LLLLJJ UM :i00 U�Q2 5 Q1O W(L(LXo ECKLUND CONSTRUCTION N.T.S PV------ -P 7A' RAILS CERTIFICATION SHEET 8431 Murphy Nye Middleton, wl 53562 USA AUTHORIZATION TO MARK, Telephone: 608.836.4400 Facsimile: 608.831.0279 www.intertek.corn Test Verification of Coinformity= N ,j �? . ... _.._.._._..._.._.M_._ W< cn a- C) 1 This �t4fh^r� the application M the Certification h4art, shown below to the rn Products) t models described in the Covered section when made in accordance with the conditions, set forth.in the Certification Agreement and Listing 1 'i , W < Report. This -authorization also applies to multiple listee model(s) identified on the correlation Page of the Listing Report 0 W Y Y Y 0 0 to Thisdocument is the property of Intertek Tesfing Services and is not transferable. The certification rnark(i) may be. W 00 0) o, IX C! applied only at the location of the Party Authorizedply To Apply Mark.N,. . ............ . . ....... .. . ....... 0 Applicant: IronRidge, Inc. Manufacturer Precision Die & Stamping, Inc. N r-4 N (D U) C/) 1495 Zephyr Ave - 11 704 W. 10th Street Cl) U) Address' Address:- Tempe, A7 W X � � 2 Hayward, CA 94544 85281 -3 W W LU Country: USA- Country: USA Z) F_ U) 1`__ U) F_ 0 U) .Contact: - Yann Schwarz Contact: Andy.Frola, 0 >_ >_ >_ ' "Phone: (8010) 227r9523 Phone: (400) 967w2018 2 (0 (0 co FAX: (707) 459=1833 FAX: (480) 829 ' �4IX138 04 Email: ysctroMrz@ironridge.com Email:, andy@pree.isiotidie..com Party Authorized To Apply Mark: Same as Manufacturer Z D IX Report Issuing Office: Lake Forest, CA 0 r to Control Number: 4008083, Authorized by: W for Thomas J. Patterson-, Certification" Manager :) Z (L i -on N ETIL CLASSSED 0 C-4 C'4 W F - C4) 0<c S U) � < U W3: W Z < Z I.- Ilk Y!5 < P C) 0 W IntertiL-k. F,_ (to 0 This document supersedes all previous Authorizatictis'to Markforthe. b > C:, E "noted Number. C%j 0 This Aulhorlitall6n to kVk ES WQ*eWU5JV0,use ofkiterteKs talent anci'ls PoAded pumuantt6 "Ceftiflca* inteffek aid itspient. iraar�w" r"parmbIny and Bab" are lurvied to the terms and condi&n of the agreernent wsrtek tosqrrwsno fiab.-M t�..a wA #Opt. I& any low expensit y "Oarty.otherthantottrio—c"in or damp occasioned W by Me use of Ow AWtorizatlon to Mark, orgy the Ofent %,atAhorMed to pern . 19 cO . M64 �0* In its eimlety. ui�e of Gft�s`.C;ertdlcalion rnerk 13 t— . ....: mdnftn - . .�- 6 ` "ot testtwtothe coMRionstaWotatn(Magre6ffiini�)iwindfs Aud to W ilia _!qt"k rwnci:for tested material, product or service must fIrst be approved in wrdinj by Intentelt; lnftW 0.ractory Asiessfft&6and pu'�'.df asauilrg aopi��ta,Uiaje of the 6ei� rnaitt to accordance with via agreement, =w 0-my.arenag for the purposes otproductlanquality and•rwi,redw6ftCDar4althe�ir6bDgbUoFnsing-�arespect. 0 Int0t6k Testinigf Services NA Inc.., 645'Eisiftan'quin "Road",,, Arlington Heijijls,)L_60005 -Telephdi;ii.8001345_3851 joi-847-439-5667, F6kM2-283-1672 U) Standard(s)':- UL'SUbject 2703* Outlihe.of Inv6sticiatibri4or Rack;Mouniing Sys and Clamping Devices for Flat -Plate * i��, _ d %., Investigation .... . I Phoiovoltaicl Modules Number. -1,.Octdber 4; 2010- Product:... - XRRaiii�,.ikWante rated.,Qtouridirig. d1tiame: IrdhRidgdRo0fM6unt_-.�: Models: XR, Rails This VePT'rdlirin hfw she e;-dhnire use of 111tOrtek'S client Old is p ovided pwsunnt ra th,, agreement. beftiveon Intcrtok OP4 its Client, forerf ek's resW,'540tyo4d flohhil(v Are B At" -ted thr tefffis and conditions of the ergreemLat. intertrk asstutres no liaMity to a" pony, ilwrito Me Client inm=ltdonctt with the cAper;se or damage occostoned by the use of this Verij`kotion. Only the ['hent is cruthotized to Wrnif coptiny or disbibution of this Any me of the hirartek.pante7or one cifits marits.ior the sate or advertisement of dw tested material, pnufqc: or service must firg be.oporoved in writing by Intertek. rtfricitred in W's VerijficGrian are fe) ".ont only to rho Sample restvilfiWcted. ftc *61.4corion byitself dovs out iniply that the rnowi* Rro'uct, arservksis�it )?as ever boon under an hiteft'vA certification progfurn, GFT.0P41a (24 -MAR -2014) mts_IT�671 —su DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor s.hall,nofifv1he * 'Designi resultof any ny "ei d; or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owneror General Contractor will be.held responsible to the resJu errors; iscrelb,606k )rror ornissiom In the event that the Owner sions,:and thecostof rectifying them. C*4 04 51 00 9CV) _j < 2 G) C) < C) Zi 00 L) I W W In to W aa X10 to Z CD 0 0 LU L) 0 uj C) W U Z D U) 0) )rror ornissiom In the event that the Owner sions,:and thecostof rectifying them. Z W D V (K Z 51 00 9CV) _j < 2 Zi 00 _3 0 < W In to W aa X10 ECKWND CONSTRUCTION! )rror ornissiom In the event that the Owner sions,:and thecostof rectifying them. n � mi CD ;0, n w I ml n � 1 O O or A I O CD CD f CO CD n- f cn � 1 N � of �i cnf cn W!1 CD 'a CD CD I i [1 � O � 1 .i o cn I CS N to coS O CA•f -•h '7 C) Ca) Er - CID o! cn ( RL 01 q Q CD W0 O ai c)- l G -)O i CD i CD I ig CD ?l m 51 O Oi g=i — `oD 1 m CD ! n cD Q;; 0 Q n lI CD O0 O CA I g CD CD =3 c� N•� oco Qco-� S C. 03 iQ CID O II{} ,n (n O O c') co 0 ? Zn - j_. O 01 cn Q I O' co i CD cn g � �i O CCD i CSD G cc d CD c' I � O! 7 CR! x c a. ECKLUND 48 MODULES -CANADIAN SOLAR - CS6P-260M Q n 117 AREZZO CT. PROJECT: 13 ,5 a N G s � 5 � � A� (n C a -13 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) � Z A n "s, SYSTEM SIZE: 11.390 KW DC (PTC) z s C v N � _.__.._ � 3 O � p 6C 3 � jr S b C rn CY�l Zt�gp Ea g s� • = O Q = 3£ o � A d 7� t� � O 3 n }� m ECKLUND 48 MODULES -CANADIAN SOLAR - CS6P-260M Q n 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US ,5 ,Sc itiT Z � s � 5 � � (n C a -13 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) � Z 12.480 KW - DC GROUND MOUNT SYSTEM SIZE: 11.390 KW DC (PTC) z C v PV SOLAR SYSTEM SYSTEM SIZE: 11.106 KW AC (CEC) _.__.._ � O � p 6C S C rn CY�l Zt�gp Ea g it • = 3 a � S E' $ O. yp�. n 7� t� � O 3 n }� m ECKLUND 48 MODULES -CANADIAN SOLAR - CS6P-260M Q n 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US .r ,Sc itiT Z � s � � � (n C PHONE: 760-200-4001 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) � Z 12.480 KW - DC GROUND MOUNT SYSTEM SIZE: 11.390 KW DC (PTC) z C v PV SOLAR SYSTEM SYSTEM SIZE: 11.106 KW AC (CEC) _.__.._ � O � p C rn CY�l Zt�gp Ea g it = }� m ECKLUND 48 MODULES -CANADIAN SOLAR - CS6P-260M Q n 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US � z Z � PALM DESERT, CA 92211 � � (n C PHONE: 760-200-4001 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) � Z 12.480 KW - DC GROUND MOUNT SYSTEM SIZE: 11.390 KW DC (PTC) z C v PV SOLAR SYSTEM SYSTEM SIZE: 11.106 KW AC (CEC) _.__.._ � Washer, Electrical Equipment Bond WEEB INSTALLATION INSTRUCTIONS For IronRidge Light & Standard Series Rails Only Burndy recommends that the sufficient details of the Installation be submitted to the AHJ for approval before any work Is started. WEEBLug-6.7 WEEB-DMC WEEB Bonding Jumper -6.7 Products are tested to UL 467, CAN/CSA-C22.2 No. -41 US/ Canadian standards for safety grounding and bonding equipment: Document Number 104-0404000039-003 ar G WIL9 �H4JBBELL . 14 © 2012 BURN DY LLC. Page 1 of 14 SYSTEM OVERVIEW Use WEEB-DMC to bond solar modules to module mounting rail. mechanically spliced rails. Use one WEEBLug-6.7 assembly per rail -to connect system to -- equipment ground conductor. Important notes 1. Use general purpose anti -seize compound on fastener threads when installing WEEBs. 2. The NEC section 690.43 states, "Exposed non-current carrying metal parts of module frames, equipment, and conductor enclosures shall be grounded in accordance with 250.134 or 250.136(A) regardless of voltage." 3. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. Document Number 104-0404-000039-003 UJI L4 2012 BURNDY LLC. Page 6 of 14 DISCLAIMER: If an Errors, Discre ancies or Omissions a ear In these dr-awin s, s ecifications or other contract documents; The Owner or General Contractor shall noti the Desii ner,in writin of suc —` ----'w _ __.__ t the caner y p pp g p .__._ - � fy g g, h error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S PV -P9 i GROUNDING SHEET d? UCD § W W U OW �o C? 0; UU) 21 0 N Hf_ W C0 a U UUU OC]Q Y Y 00�o ,*: m 17 C14 0 Z 0 W Q a� Z o `; M _s a U W m Z W U W W W OD U M J 00 aL0 U) ECKLUND CONSTRUCTION Z 1 1 Q L Z W i D m } ! 0� N SFW co" Q } Q Q i Q U Y g� Z a W O =C)O(0» F— v N> O U a U i cn�a��0 0 Z 0 W Q a� Z o `; M _s a U W m Z W U W W W OD U M J 00 aL0 U) ECKLUND CONSTRUCTION GENERALNOTES 2013 CEC, 2011 NEC, LAFD-MARKINGS, LABELS, AND WARNING SIGNS REQUIRED A. Main Service Disconnect: CAUTION SOLAR ELECTRIC SYSTEM CONNECTED 1. Residential buildings - the marking may be placed within the main service disconnect. The marking shall be placed on the outside cover if the main service disconnect is operable with the service panel closed. 2. Permanent labels shall be provided , no sharpie marking will be allowed within any main service panel or subpanel. 3.AII National Electric Code, and Fire Department required labeling will be made of sunlight and weather -resistant material. Labeling on disconnects, inverters and service panels will be made of an engraved, plastic material and be permanently attached to its respective device. All labeling shall be attached directly to those pieces of equipment. 4.Markings: Verbiage, Format, and Type of Material. a. Verbiage: WARNING POWER TO THIS BUILDING IS ALSO SUPPLIED BY PHOTOVOLTAIC SOLAR SYSTEM, DO NOT TOUCH TERMINALS b. Format: (1) White lettering on a red background. (2) Minimum 3/8 inches letter height. (3) All letters shall be capitalized. (4) Arial or similar font, Non -bold (5) Reflective weather resistant material suitable for the enviroment (durable adhesive materials must meet this requirement) B. Marking Requirements on DC Conduit. Raceways, Enclosures, Cable Assemblies, DC Combiners, and junction boxes: 1. Markings: Placement, Verbiage, Format, and Type of Material. a. Permanent Placement: Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and/or below penetrations, all DC combiners, and junction boxes. b. Verbiage: CAUTION SOLAR CIRCUIT c. The following label to be placed on all AC disconnects CAUTION SOLAR CIRCUIT DISCONNECT NEAR GROUND -FAULT INDICATOR STRING INVERTERS ONLY (Art. 690.5 (C) CEC) PLACED ON MAIN ELECTRICAL PANEL Qv1``►� n OF pEpS, FE gv1L01NG' $` SOv �� Ap?o 'Uc-c1ON WILYA 0191 .. i� .e FOa /4 PLACED ON MAIN PANEL ADJACENT TO THE PV BREAKER(S). (CEC 690.64 B 7) PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES, AND DISCONNECTS. MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET (3048MM), WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOFICEILING ASSEMBLIES, WALLS OR BARRIERS.CFC 604.11.18 CRC R331.2 PLACED ON SERVICE ENTRANCE PLACED ON EACH DC DISCONNECT INVERTER 690.54 PLACED ON AC DISCONNECT ON ALL DC CONDUITS RACEWAY EVERY 10'& "J" BOX PLACED ON MAIN PANEL DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S PV -P10 I WARNING LABELS I co U a? �o C7 cca �w rn w �0 0 U� UW Ow �Z N w W a U mrno v C! N e- .- N N N U)CDU) W W W V)CnU) W a o(D Z ON i O O � U Q U o � i Z w Wm o_ � M , 0 N U pp F CN M O w 6 0 w�u)g<U I r -Z i cIo y W O 2 0 0 U)�= �00u)>CU a o- 2nj>0U rn—a—0 W a o(D Z ON ECKLUND CONSTRUCTION 0 0 O Q U U Wm F- C) C) USN U pp W o O w 6 0 c cIo y W w UM U�QS f- U') W aa xo9 ECKLUND CONSTRUCTION ml c" o o � � A i 1 CD• O A Cn O N ; � O_ o O n' CD N ' N. 1S O_ CDO O Cn O CSD N � 2 o' CD CD CL:i C1 Q N cn o CD �R o o � CD CD s oi CD �1 C o QI M o? 1 cf) _� o may, lu 6 , u, o� n CD m CD i , C!) N n O O Cr n . O O O Cn (?D N Cn O_ Cv CD O: CD L o o N � C m cn r r ov m a n m v 0 m W C n m `Am I� _C m Z 0 m n 0 oTz0 z -ng CC) -q O y � <m.0 c �Mz �D C7 M ECKLUND 48 MODULES - CANADIAN SOLAR - CS6P-260M 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US z zn %C PALM DESERT, CA 92211 �l C PHONE: 760-200-4001 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) in z 12.480 KW - DC GROUND MOUNT SYSTEM SIZE: 11.390 KW DC (PTC) w v SOLAR SYSTEM SYSTEM SIZE: 11.106 KW AC (CEC) a X 10 10 VISTA LAZO --� LA QUINTA CA, 92253 O DOUG EXKLUND, CONTRACTOR OCCUPANCY R3 / TYPE 5 STRU. z TATE LICENSE# LICENSE CLASS EXPIRATION DATE 558389 a 07/31/2016 01'j .. I / GENERAL NOTES: N.T.S PV -P1 COVER SHEET 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. ARRAY - 48 MODULES 2. NO SHEET METAL OR TECH SCREWS SHALL BE USED TO GROUND DISCONNECT ENCLOSURE WITH TIN-PLATED ALUMINUM LUGS; PROPER ARRAY TILT =100 GROUNDING/GROUND BAR KITS SHOULD BE USED. ARRAY AZIMUTH = 270' 3. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WITH RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS.(CEC 314.15A). 4. BACK -FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM GROUND MOUNT THE UTILITIES. C 5. ALL CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. d- a w 6. SMOKE ALARMS AND CARBON MONOXIDE ALARMS MUST BE INSTALLED PER THE 2010 CALIFORNIA RESIDENTIAL CODE AND VERIFIED 'U � o �s a � PRIOR TO FINAL INSPECTION APPROVAL PER CRC R314 & R315 w o o Q 7. ALL WORK TO COMPLY WITH 2013 CALIFORNIA BUILDING CODE; 2013 ELECTRICAL CODE CEC - ARTICLE 705.12, ALL MANUFACTURE'S w o LISTING AND INSTALLATION INSTRUCTIONS. O Ch (9 8. GROUND MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED IN ACCORDANCE WITH UL1703 0 v M 0 a SECTION R902.4 (CRC) & 1509.7.4 (CBC) UNGROUNDED INVERTER W 9. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. POSITIVE GROUNDED INVERTER ❑ v `�' N N N N 10. ALL CONDUITS AND EQUIPMENT SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND MATERIAL COLOR OF THEIR LOCATION. cn to cn w st st w w 0 0 11. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE -PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM. (CEC NEGATIVE GROUNDED INVERTER ❑ � ii Ln cn 250.97) . 0 � >_ � 0 W W 12. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR ENPHASE MICROINVERTERS El2 N UNLESS OTHERWISE NOTED OR STANDARDIZED. 13. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 14. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS, THIS PROJECT SHALL COMPLY WITH THE o ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND U) SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE2013 CA BUILDING CODE ? a COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 2013 CA PLUMBING CODE 02 N 15. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. w N 16. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 2013 CA RESIDENTIAL CODE C) U) o Q 17. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. 2013 CA ENERGY CODE � v 18. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. 2013 CA MECHANICAL CODE W Y g z a 19. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE 2013 CA FIRE CODE w s a O cn D Z) SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED 2013 CA ELECTRICAL CODE - 2011 NEC a N a g o THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53, 690.35(F), 690.54, 690.64(B)(7) AND 705.10 ORDINANCES OF THE CITY OF LA QUINTA TO, a 20. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. 21. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. SHEET INDEX VICINITY MAP 0 N PV -P1 _ Cover Sheet P6 - Inverter Sheet wry a�"i"45: `a �^,� _� `''�°- CANADIAN SOLAR-CS6P-260M& C� P2 Plot Plan P7 - Rails `` SOLAREDGE - SE6000 AUS w S .. , P3 -Three Line P7A- Fire Rating Rails r h ' ` ' t•l sw uN. Z o _ _..Y:� P4 - Structural View P8 - Attachments ,' - P5 - Module Sheet P9 - Grounding j �' = LISTED BY UNDERWRITERS LABORATORIES FOR ELECTRICAL o z o t3 5 W 6 ` ' Q Co PSA- Fire Rating Sheet P10 -Warning Labels G -- __ ; " $ I AND FIRE SAFETY u_ - o z P11- Placard 1 tri U'- (CLASS A FIRE RATING) O U N f I d: IFj o w o o z , w l ��NU)CCD zww .. 2 w = 0) z 00 n 1 NOTE: NO DISCHARGE OF ANY POLLUTANTS x : S2 M TO ANY STORM DRAIN SYSTEM. Y _j 0 W � - 2) UL 1703 FOR MODULES & UL 1741 FOR INVERTERS "u, a X °o= _" -� Prepared by (MQ: I "``_- --�"'� =� �- PER CITY SOLAR REQUIRMENTS. i ; a. wwwsolarpermitservices.cam �, x �, n � ' ,I 2013 CEC, 2011 NEC, CITY/COUNTY FD -MARKINGS, ECKLU N D � Solar PermitaSer-vices; Tnc i� 2ia2� �"m.00m ' — ` ` LABELS, AND WARNING SIGNS REQUIRED ROOFING INC i l DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. in CANADIAN SOLAR - CS6P-260M 38.7" x 64.5" N.T.S NOTES: -WORKING CLEARANCE FOR MAIN SERVICE PANEL AND AC DISCONNECT EXCEEDS 3' 2013 CALIFORNIA ELECTRICAL CODE 2013 CEC ARTICLE 690 ALL MAN FACT RES' a 0 N 241'-2" P/L L AROUND ARRAY _ES GROUND MOUNT ARRAY 48 MODULES ARRAY TILT @ 10" ARRAY AZIMUTH @ 270° (E) PULL BOX ("J" BOX) i 270' TRENCH 18" UNDERGROUND 1/2" PVC SCH. 40 /i 101-0" i 3't EXISTING WALL i J- BOX UNDER ARRAY / SEALED TIGHT jNON-FUSED - NEMA TYPE3 MIN. (TYP) i i 10' TRENCH 18" UNDERGROUND j1-1/2" PVC SCH. 40 i i (N) 2 INVERTERS- ��/ SOLAREDGE-SE6000A-US-240V j MOUNTED TO WALL (N) 100A 240V PV SUB PANEL SCALE '32" = 1'-O" PV -P2 PLOT PLAN M O W (n (V OCD c~naU Cq 0 ,w OOQ W U) W co M '9T M o r r O W W W L) , NNN W D H H H 0 } } } C/) C/) U) N z Z O H O LO z W _ M d 04 H 0) M 0 >- Oy U U) C/) L) �Z Y � z a w =00cnZ)Z) p 00'U)jaU a U) d Q0 w Q o(D Z o ON F M O CL x [ ) ...... � w LISTING AND INSTALLATION INSTRUCTIONS. �O� /SP z_ N _ W U)) -PV EQUIPMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTION /J~� 0 � V U SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. (NEC 690.4 E) / do z U L m -PHOTOVOLTAIC SYSTEM CONDUTORS SHALL BE IDENTIFIED AND GROUPED. THE — — — — — — — / / O V O V MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR 199'-0" P/L / O � N 7 CODING,MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. (NEC 690.4 B) W O W O o # N W zrn D Ix W U M YQ_3O WM SCALE: w - aa xg I.- LO co 1/32 "=1'-011 ECKLUND ROOFING INC DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. ELECTRICAL NOTES: E1. ALL EQUIPMENT IS LISTED FOR USE. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. E7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM (SOLAR EDGE INVERTERS 50OVDC RATED MINIMUM). E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E11. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E12. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E13. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL THAT ARE CONNECTED AS AN EXPANSION SPLICE. BI-DIRECTIONAL UTILITY METER NOT CENTER FED PANEL MAIN ELECTRICAL PANEL (E) 400AMP 120/240V (E) 200A & (N) 175A MCB Lv-----T-1 E14. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E15. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E16. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. E19. ALL MODULES AND RACKING SHALL BE GROUNDED USING UL 2703 LISTED RAIL INTEGRATED GROUNDING SYSTEM, OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS OR WEEBS. 2 STRING OF 12 PANELS 2 STRING OF 12 PANELS ■ IN SERIES &PARALLEL IN SERIES & PARALLEL 300 - POWER OPTIMIZER Z� I Z� -i UNDER EACH MODULE + �" I I Dc I I DC DC I I I Bc. GROUND WIRE BARE I DC - D CI I Dc NEC 250 (TYP) I I J (4) #10 CU PV -WIRE NEC 300.6 C1 ARRAY RATING #1 & #2 CEC 690.8(A)(1),(B)(1) each ISC = 8.99 *1.25*1.25=14.05A INVERTER DC MAX INPUT CURRENT = 23A VOC = 37.8 * 1.13 = 42.71 WDC Input voltage 365/12 = 30.42 Vdc modules per string Total 6240/365V = 17.10 INVERTER INVERTER DC MAX INPUT VOLTAGE = 500 V/DC 200A x 120% = 240A 48 * 237.3 * 0.975 / 1000 = 11.106 KW -AC (CEC) 48 * 237.3 / 1000 = 11.390 KW -DC (PTC) 240A - 175A = 65A UTILITY TILITY GRID TO1201240V SINGLE PHASE 65A >_65A PV -CB BI-DIRECTIONAL UTILITY METER NOT CENTER FED PANEL MAIN ELECTRICAL PANEL (E) 400AMP 120/240V (E) 200A & (N) 175A MCB Lv-----T-1 E14. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E15. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E16. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. E19. ALL MODULES AND RACKING SHALL BE GROUNDED USING UL 2703 LISTED RAIL INTEGRATED GROUNDING SYSTEM, OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS OR WEEBS. 2 STRING OF 12 PANELS 2 STRING OF 12 PANELS ■ IN SERIES &PARALLEL IN SERIES & PARALLEL 300 - POWER OPTIMIZER Z� I Z� -i UNDER EACH MODULE + �" I I Dc I I DC DC I I I Bc. GROUND WIRE BARE I DC - D CI I Dc NEC 250 (TYP) I I J (4) #10 CU PV -WIRE NEC 300.6 C1 ARRAY RATING #1 & #2 CEC 690.8(A)(1),(B)(1) each ISC = 8.99 *1.25*1.25=14.05A INVERTER DC MAX INPUT CURRENT = 23A VOC = 37.8 * 1.13 = 42.71 WDC Input voltage 365/12 = 30.42 Vdc modules per string Total 6240/365V = 17.10 INVERTER INVERTER DC MAX INPUT VOLTAGE = 500 V/DC MAIN PANEL PV -CB SIZE= 65A 48 * 237.3 * 0.975 / 1000 = 11.106 KW -AC (CEC) 48 * 237.3 / 1000 = 11.390 KW -DC (PTC) ISC: 8.99 ADC IMP: 8.48 ADC INVERTER AC MAX OUTPUT CURRENT IS: 25 * 1.25 = 31.25A x 2= 62.5A L Z W UNGROUNDED. UNGROUNDED J- BOX ON ROOF SEALED TIGHT NON-FUSED -NEMA TYPE3 MIN. J -BO LLJ C7 w 0) M INVERTER #2IL O Oy INVERTER #1 SOLAR EDGE SOLAR EDGE g W�D' �Z �Yg�za LU 2oOv»> p SE6000 A-US11240VSE6000 DO U) j O U A-US11240V g 0 MAX EFFIC. 97.5% MAX EFFIC. 97.5% 15' EXTERIOR 3/4"EMT DC CONDUIT - - I (4)#10 CU THWN-2 CONDUCTORS (1)# 8 CU THWN-2 GROUND IIA cFP 11A cFP 90*C WET & DRY I M�� EGC x� III + ® - M�� EGC w t, + ® - (N) 65A 2 POLE BREAKER & ADJACENT TO MSP AC DISCONNECT (N) 1 ODA 240V AC DISCONNECT I SHALL BE INSTALLED AT OPPOSITE NON -FUSIBLE 2POLE,LOCKABLE KNIFE L END OF MAIN CIRCUIT BREAKER BLADE,NEMA 3R 6.3 & NEC690.17 AIC RATING OF (N) 1ODA 240V PV 22,000A SUB PANEL 2-35A 2POLE BREAKERS -1 1 EXISTING I I ('J'LBO) E3 MOUNTS AND EQUIPMENT I ENCLOSURES GROUNDED 1 TO MAIN PANEL GROUND (E) LIFER GND J L 2'-1 -1/2" EMT AC CONDUIT (3)#1 CU THWN-2 CONDUCTORS (1)#6 CU THWN-2 GROUND 90*C WET & DRY 270' TRENCH 18" UNDERGROUND 1-1/2" PVC SCH. 40 AC CONDUIT (3#1 CU THWN-2 CONDUCTORS (1)#6 CU THWN-2 GROUND 90*C WET & DRY PTC RATING IS:237.3W ARRAY RATING #1 & #2 CEC 690.8(A)(1),(B)(1) each ISC = 8.99 *1.25*1.25=14.05A INVERTER DC MAX INPUT CURRENT = 23A VOC = 37.8 * 1.13 = 42.71 WDC Input voltage 365/12 = 30.42 Vdc modules per string Total 6240/365V = 17.10 INVERTER INVERTER DC MAX INPUT VOLTAGE = 500 V/DC MAIN PANEL PV -CB SIZE= 65A 48 * 237.3 * 0.975 / 1000 = 11.106 KW -AC (CEC) 48 * 237.3 / 1000 = 11.390 KW -DC (PTC) ISC: 8.99 ADC IMP: 8.48 ADC INVERTER AC MAX OUTPUT CURRENT IS: 25 * 1.25 = 31.25A x 2= 62.5A L I 3/4" EMT AC CONDUIT (3)#10 CU THWN-2 CONDUCTORS (1)#8 CU THWN-2 GROUND 90*C WET & DRY CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: AC REQUIRED CONDUCTOR AMPACITY 35+35=70A AWG # 1 DERATED AMPACITY: (130) (0.91) (1) =118.3 A 118.3 A > 80 A, THEREFORE AC WIRE SIZE IS VALID. CALCULATIONS FOR CURRENT CARRYING CONDUCTORS: DC REQUIRED CONDUCTOR AMPACITY [NEC 690.8(8)(1)1- 8.99 * 1.25 90.8(8)(1)1:8.99.1.25 * 125 =14.05 A AWG #10, DERATED AMPACITY: (40) (0.58) (0.8) =18.56 A 18.56 A> 14.05A, THEREFORE DC WIRE SIZE IS VALID. LAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV -P3 I THREE LINE ELECTRICAL M CD CO to D- Q o C 0 W C0 OW U)C3 W 10. O U� I i U) O W N N_ _N N_ 07 0 (7 222 0U)(0 0U)U) U CN Ur O) O Z CD U � OVEN Q N W CD N U)W Z LU Z LU 0 W Z J Q U � Q 0 W CL Il LU o� zb ON F M FL O X W Oco U v LU CO m z C� p w U zrn U.1 o0 U M JL0 1-0 ECKLUND ROOFING INC H- Z U) L Z W M D_ In LLJ C7 w 0) M O Oy � V U g W�D' �Z �Yg�za LU 2oOv»> p DO U) j O U OL g 0 U) CL U CN Ur O) O Z CD U � OVEN Q N W CD N U)W Z LU Z LU 0 W Z J Q U � Q 0 W CL Il LU o� zb ON F M FL O X W Oco U v LU CO m z C� p w U zrn U.1 o0 U M JL0 1-0 ECKLUND ROOFING INC N Ur O O N 1p L N CD 7 X O W (D N T N O O Q p 0 _ iu F• � d o ao m CDD �� o n CL m n n 3 n n 3 3 = d 3 � d o o _v N XO 0 N N Dr —1' ECKLUND ROOFING INC 1 48 MODULES -CANADIAN SOLAR - CS6P-260M O m 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US O N n O n x WCL (D O O. co d N O 0 a C ryr (D NO O A p — O N O N (D (n CD z r fD �4'.5• D ECKLUND ROOFING INC 48 MODULES -CANADIAN SOLAR - CS6P-260M O m 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US c Z O n PALM DESERT, CA 92211 �1 PHONE: 760-200-4001 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) n 6 z r 12.480 KW - DC GROUND MOUNT SYSTEM SIZE: 11.390 KW DC (PTC) c C PV SOLAR SYSTEM SYSTEM SIZE: 11.106 KW AC (CEC) Z X 10 VISTA LAZO � 0 LA QUINTA CA, 92253 m DOUG Exla uND, CONTRACTOR ^Z OCCUPANCY R3 / TYPE 5 STRU. TATE LICENSE# LICENSE CLASS DATE l J 558389 1 B JEXPIRATION 07/31/2016 Key Features • High module -efficiency up to 16.16% • Positive power tolerance: 0—+5W • Robust frame to up to 540.0 Pa load • Self-cleaning surface • Outstanding performance at low irradiance • High energy yield at Low NOCT • Backed By Our New 10125 Linear -Power Warranty Plus our added 25 year insurance coverage 1n Added Value 90% From Warranty 60% 0% s 10 is 20 25 �°� CanadianSolar • 10 year product warranty on materials and workmanship • 25 year linear power output warranty CS6P Is a robust solar module with 60 solar cells. These modulescan be used foron-grid solar applications. Our meticulous design and production techniques ensure a high -yield, long-term Performance forevery',tnodule. produced. Our rigorous quality control and to -house testing facilities guarantee Canadian Solar's modules meet the highest quality standards possible. Best Quality • 235 quality control points in module production EL screening to eliminate product defects Current binning to'Improve system performance • Accredited Salt.mist/Ammonia resistance Best Warranty. Insurance • 25 years worldwide coverage • 100% warranty term cove rage • Providing third party bankruptcy rights Non -cancellable • Immediate,coverage • Insured by 3 world top insurance companies Comprehensive'Certificates • IEC 61215, IEC 61730; I EC61701 E102, UL170.3, IEC62716; CEC Listed, CE and MCS • IS09001:'2008: Quality Management System • ISO/TS 16949:2009: The automotive quality management system • IS014001:2004: Standards for Environmental management system • QC080000 HSPM:The Certification for Hazardous Substances Regulations • OHSAS 18001:2007: International standards for occupational health and safety www.canadiansolar.com CS6P-240/245/250/25:5/260M Electrical Data CSBP-260M Temperature Characteristics 260W STC CS6P-240M CUP -2450 CUP -250M CS6P-25$IV CS6P-260M Nominal Maximum Power Pmax 240W 245W 25OW 255W 188W O 9mum0peratIngVoltage 30,2V 30.3V 30AV 30.5V 30.7V Optimum0peratingCurrent (Imp) 7.95A 8.09A 822A 8.35A 8.48A Open Circult Voltage (Voc) 37.3V 37AV 37.5V 37.7V 37.8V Short Circuit Current (Ise) 8.46A 8.61A 8J4A 8,74A 8.99A Module Efficiency 14.929( 15.23% 15.54%6 15.85% 16.16% OperatingTemperature U)U)U) -40'C-+85'C 0 M MarilmumSystem voltage (r) 1000V IEC /60OV UL L) a s Maximum Serles Fuse Rating lZ to X 16A. Application Classification ClaSSA PowerTolera nce 0- +5W Under Standard TestCandillons (STC) or Irradiance ar 10oow/m', sped,umAM 1.5 and cea"erat re at 2510 NOCT CS6P-240MCS6P-245MCS6P-250MCS6P-255 CS6P-260M 'Nominal Maximum Power Pmax 173W 177W 180W 184W 188W Optimum operating Voltaa Vm 27:6V 27.8V '27.7V 27.8V. .28.OV 'Optimum Operating Current (Imp) 6.29A 6.40A 6.51A 6.62A ;6:70A Open Circuit Voltage oc 34.2V 34.3V 34AV 34.6V 34:7V Short Circuit Current (lee) 6.85A 6.97A 7.08A 7.18A 7.28A. Under Normal opereUrq CellTemperature, Irredlance ora00 W!m', epe"AM t.s, emtlerglenpereture, 20C, wI nAspeed 1 m!a' Mechanical Data Coli type Mono -crystalline 1,66:x 156mn% 2 or 3.ausbara . +dellArrangament 60 (8'x 10) Olmenslons 1638 x 882 x.40mm (64.5-x 38J h.1.571n) Weight 19k9 (41.9 lbs) , Front Cover 32mm Tempered glass Frame Material Anodized aluminium alloy J -80X, IP65 or IP67,1 diodes Cable' 4mm'(IECy12AW�(UL),1000mm :Connectors MC4 orMC4 Comparable Standard Packaging (Modules per Pallet) 240cs Module Pieces per container (40 ft. Container) 672pcs(40tHO) IN Curves (MP -250M) Srtl,on A•A r f� a 1.5 warrvi „aa.�NV1 'Spedfloatlore Included In Ws atesheet ore subject 10 change VAthout prlorno0ee. About Canadian Solar Tempe retureCoeRiclem961^10 %f9L' nPeratUrMe Ise %NC Normal Operating Cell Te?C Performance at Low Irradiance Industry leading performance at low irradiation en4ironment, +95.596 module effclencyfrom an irradiance of 1000w1m'to200w/m' (AM I.S. 25 C) Engineering Drawings Canadian Solar Inc. Is one of the world's largest solar Canadian Solar was founded In Canada In 2001 and was companies. As a loading vertically -integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In manufacturer of Ingots, wafers, cells, solar modules and November 2006. Canadian Solar has cell manufacturing capacity solar systems, Canadian Solar delivers solar power of 1.SGW and module manufacturing capacity of2.3GW. products of uncompromising quality to worldwide U)dU customers. Canadian Solar's world class team of a) M professionals works closely with our customers to 006 provide them with solutions for all their solar needs. • - - - • , , - - - _ , , , West EWR.•&s20Mfi t1a2013CNSd0Sd&the LAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV -P5 MODULE SHEET M Z O 0 CD to Q p co (V � 0 U') z W cDo U)dU 0 a) M W 006 X 0 0 Q W W of < Z IXYg�Za w = 0 0 (n p v(0 j d U W 11� M a N U) Ill LLl Ill U N N N U) U) J W W W ONWr-- D 0 tn(n(n U)U)U) pipp �1 N ECKLUND ROOFING INC Z w 0 Q p co 0 U') z W Z o ON 0 to 0 toN a) M O X U) W of < Z IXYg�Za w = 0 0 (n p v(0 j d U v � U o a (n , Il 5 O ECKLUND ROOFING INC w Q p co Z o ON QrQ� ao X w U z N O vi 0 04 _ D) o v U Z U Um Wo OUwN QUp z 2 ONWr-- D v> LU O WLU cc) � lY 0 M YQ_jO (r) UJ to L) a s o lZ to X ECKLUND ROOFING INC �°� CanadianSolar • Do not drop or place objects (such as tools) on the 5.0 modules. MODULE INSTALLATION Do not carry modules on your head. .? Do not use sharp instruments on the modules. Particular care should be taken to avoid module backsheets being damaged by sharp objects, as 41�� r. scratches may directly affect product safety. Do not leave modules unsupported or unsecured. 1 Do not change the wiring of bypass diodes. a INSTALLATION MANUAL OF STARDAND SOLAR MODULES (UL) Keep all electrical contacts clean and dry. PRODUCT IDENTIFICATION Each module is equipped with two .identical barcodes (one inside the laminate under the front glass, the second on the rear side of the module) that act as a unique identifier. Each module has a unique serial number containing 13 (pre March 2013) or 14 (post March 2013) digits. —�-� A nameplate is also affixed to the rear of each module. This nameplate specifies the model type, r � as well as the main electrical and safety characterk M stics of the module. PRECAUTIONS MEASURES AND GENERAL SAFETY Prior to installing modules please obtain information about any requirements and necessary approvals for the site, installation and inspection from the relevant autho- rities. SYSTEM FIRE RATING The fire rating of this module is valid only when mounted in the manner specified in the mechani- cal mounting instructions. Canadian Solar Inc. modules have been certified CSA as Type 1 for fire performance. When installing the modules on rooftop, please er sure the assembly is mounted over a fire resistant roof covering rated for the application. A photovoltaic "systems composed of U"L1703 certified modules mounted on a UL2703 certified mounting system should be evaluated in combina- tion with roof coverings in accordance with UL1702 standard, with respect to meeting the same fire classification as the roof assembly. Mounting systems with a System Fire Class Rating (Class A. B or Q, tested in conjunction with fire rated 'Type 1" rated modules, are considered ac- ceptable for use with Canadian Solar Inc. modules, provides the mounting system does not violate ani other requirements of this manual. Any mounting system limitations on inclination or accessories required to maintain a specific System Fire Class Rating should be clearly specified in the installation instructions and UL2703 certification o the mounting system supplier. DO NOT STAND OR STEP on the modules under any circumstances. Localized heavy loads may cause severe micro -cracks at cell level, which in turn may compromise module reliability. Failure to comply with the above caution will void Canadian Solar Inc.'s warranty. DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the C or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV-P5A MODULE CERTIFICATION SHEET 2 0 co V) a� o 0 U) W �0 H W O� W (V IU—Hw cn a U COQ 0000)0 � M N r - N N N U)U)U) w w w U) U) CO U)U)CO UCn 04 F - Z O N 0a) O c) g Z O' 0 LO Z w cY } in� W N C7� 0M v Q } n O o WwN U U)ggN U o W ofQ Q � Z L) N w = 0 O C p z0) "tUjC7U cr W 00 a v)�D--�O )C) YQ_JO LU H U W� o� Z o ON U.1 Xo< � M O (L x w UCn 04 O N 0a) c) g Z O' C CO v 0OV O o WwN o � N w z0) w W 00 )C) YQ_JO U W� aa �L0 U.1 Xo< ECKLUND ROOFING INC solar• SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US SE760OA-US / SE1000OA-US / SE1140OA-US The best choice for SolarEdge enabled systems • Integrated arc fault protection (Type 1) for NEC 2011690.11 compliance Superior efficiency (98%) Small, lightweight and easy to Install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional - revenue grade data, ANSI C12.1 USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA - AUSTRALIA- THE NETHERLANDS -ISRAEL www.solaredee.us soar,: 1 Single Nnase Inverters for North Arnorica SE3000A- US/ SE3BOOA-US/SE5000A- US/ SE6000A-US] SE760OA-US/SE10000A-US/SE11400A-US SE3000A-US SE38WA-USSESWOA-US E6000A-US SE760OA-US SE10000A-US SE1140OA-US OUTPUT 7500 9500 Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400VA ....... Part15 class FCC ss B ............................................................... I .......... .......... I..... ................ ............... IOODO.@Z44V................... ........... Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V12000 VA .............................................. ........................5450�240V Input Voltage .................... .... .10950,@240V............,...... .......................... AC Output Volgge tvlin: Nom: Max.01 , Nom. OC InFIIt MIM ................ .............. 325 @ 308V / 350 240V 183: 208; 229 Vac ............... Vdc Max. InputCurrend't ✓...... 13 AC Output Voltage Min. -Nom. -Max ") 18 23 33 @ 208V 34.5 L......... 211-240.264 vac Weight with Safety Switch _95 51.2 / 23:?........._ ...... . 54.7 / 24 7 ............. AC Frequency Min. -Nom :Max!) 59.3 - 60 :60.5 ( i11country s .......................... ttilrg 57 - 60 - 60.5) Hi Max Continuous0utputCurrent ............. ... .............: .. 24 @ 208V 12.5 � 16 I ,HI ... 25 ............. . ............ 48 @,208y 32 47:5 ......... A Reverse:Po Oty.Protection ... 21 @,240V. ...... . .................. 42 @ 24Q�..................... . ....... GFDI Threshold ........,._..._ .. 1 I ...... I ............... .... ....... ................................................... A Utility Monitoring; Islandirig Protection Country Configurable Thresholdses 98.2 ..,...... ..::............_. 98.3 Yes Recommended Max. DC Power" 3750 47506250 0 7500 9500 12400 14250 w . STO.............................................................. ....... Part15 class FCC ss B F- M M .... ............... O � ................ .............................., - ......... Transformer -less, Ungrounded .................. ..Max. ........................................................:500.........:............................................... Yes M .�..... Input Voltage .................... ..................:................................. .......................... .................... , Nom. OC InFIIt MIM ................ .............. 325 @ 308V / 350 240V . Vdc Max. InputCurrend't 30.5x12.5x10S/775x315x260 13 16.5 @ 208V I,155�240V.L•.,. 18 23 33 @ 208V 34.5 L......... Adc Weight with Safety Switch _95 51.2 / 23:?........._ ...... . 54.7 / 24 7 ............. . 88 :4 / 40:1...._...._....._...... ....... lbj. �R.. 1.30Sfr1a 240V.. ................. . .. Max. Input Short Circuit Current ........... 45 Arlt Reverse:Po Oty.Protection ... ............................................. Yes LU -13 to +140 / 45 to +60 (40 to +60 version available)") Ground -Fault Isolation Detection ........,._..._ .. ....................,...................I... 600ka5ensty I ...... I ............... .... ....... ................................................... .... ......................... ............. mEfficiency7 Maxt umInverter 97. 98.2 ..,...... ..::............_. 98.3 98.3 98 ,. l 98: 98 9b CEC Weighted Efficiency.;....::..'.. 97.5 98 @ 208V.I.......7 975 97. 97.5 97 @ 20$v l 97.. .. r4-40 vertlmi P/N: SELEMA AMNNu4 „ ..... ,1 ................97.5 98 @ 240V .., .I. 97:5 @ 240V .I.....,......• Nlehtttme PowerConsumotion <2.5 <4 w Supported Communication Interlaces R5485, RS232 :Ethemet, Egged (options)) ....................................................................... Revenue Grade Data, ANSI C12.1 Optionatl') ,... ?n. ......................................................... Rapid Shutdown - NEC 2014 690.12 Functionalityenabled.when SolarEdge rapid shutdown kit fs. installed)') Safet ....... UL1741,UL16998,UL1998,CSA 22.2 ' 0 Grid Connection Standards rn .IEEE1547..... ............................................... .. to Z w ................................................................... F- F- U ....... Part15 class FCC ss B F- M M INSTALLATION SPECIFICATIONS O � w AC output conduit size / AWG range 0 W 3/4" minimum/ 16-6 AWG 3/4" minimum/ 8.3 AWG =o0cn» .... i............ strings .. DC input wndult site / q of str(ngs / M ..................................................... ................................................ X AWGrange...................................................................................................................................................... 3/4" minimum / 1-2 strings / 16.6 AWG 3/4' minimum / 1-2 strings / 14.6 AWG ........... Dimensions with Safety Switch G7 305 x 12.5 x 7 / 30.5 x 12.5 x 7.5 / 30.5x12.5x10S/775x315x260 in / ,,,,,,,,,,, .......................................................... HH FW - 775x315x172 775x3]S,g191........ „-, ........................................................ 9n Weight with Safety Switch fn to to 51.2 / 23:?........._ ...... . 54.7 / 24 7 ............. . 88 :4 / 40:1...._...._....._...... ....... lbj. �R.. Cooling ............................... ................. NaturalConvection ................................. Fans (user replaceable) ............................... ........... Noise <25 <50 i Min: Max. OpetatingTemperature LU -13 to +140 / 45 to +60 (40 to +60 version available)") 'F /'C Range. .................................. ...................... I ...... I ............... .... ....... ................................................... ......... Protection Rating NEMA 3R 0 cc Q P) rot ather regional settings pkme mmaa SolarEdge support. U M p1 OW and town: limited to"135%ol AC power, 7AW and higher. limited to 125% for badom where the yearly average ho raWrature b above 77'F/25'C and to 135%for orations where It b below 77'F/2S'G For detailed hdmnadon, refer to do wenhine aulde.odl. (9 p1A higher arrest source may be med; the Inverter will Ilmh Its Input aetem to the values stated. I'lRevenue grade Inverter P/rt: Sfm="JS000NNR2 w a d M Rapid shutdown lit P/N: SE100PRSD•S1 r4-40 vertlmi P/N: SELEMA AMNNu4 N.T.S I PV -P6 I INVERTER SHEET I 2 0 co (n rn N a. to Z w toQo F- F- U 0 F- M M O � w D Q 0 W Of Z aHZCi- 0 w =o0cn» p M wco T X N r r LU W w U N N N G7 W' O vi HH FW - v U) >_ } } N fn to to DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. ECKLUND ROOFING INC 0 W F rn to Z w Z) M Il 0 toN F- M M O � Z O ON rn V Q U Of Z aHZCi- 0 w =o0cn» p F-: j C7 U Q_ X ren -CL— 0 DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. ECKLUND ROOFING INC W F O� Z O ON FQ- � a o X W Z N O vi _ C7 0) C) v U Z U Um LL OV N C 0 W0w6 -- N * LU w 0 cc Q U M Y _j 0 (9 wM w a d �ln XD DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. ECKLUND ROOFING INC .solar o WO& 0 SolarEdge Power Optimizer 0 Module Add -On For North America OP250-LV / OP300-MV / OP400-MV / OP400-EV °�- PV power optimization at the module -level - Up to 25% more energy - Superior efficiency (99.5%) - Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading - Flexible system design for maximum space utilization - Next generation maintenance with module -level monitoring - Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN CHINA - ISRAEL - AUSTRALIA sola r m o SolarEdge Power Optimizer Module Add -On for North America OP250-LV/ OP300-MV/ OP400-MV/ OP400-EV. MV 11 OP400-MV INPUT Rated Input DC Power'250 ............... ......... ......... 300 400 400 ............................................................... W ......... Absolute M1.aximum Input Voltage (Voc) ... 55 75 75 125 Vdc MPPTOperatingRange.... ..... .....5:.75.... .....S:.75.... .. 15:125.. Vdc..... Maximum Short Circuit Current (Isc) of connected PV .....5.-.5.5 10 10 10 7 Adc Module _ Double insulated TT ,_MC4 FL X Maximum OC InputCurrent.. ......125................12:5.... . 1........ ..................... .Adc .......................... Maximum Efficiency 99.5 .;.................:........ %...... Weighted Effic.en cy................ .. :...;•:: 98.8 ...... ........ .......................... Ovenioltage Category, II % OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current ............................................................................................................................._........................................ 15 Adc .Operating Output Voltage 5 - 60 Vdc, OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER, OR INVERTER OFF) STANDARD COMPLIANCE EMC FCC Part15 Class 8, IEC61000-6-2,1EC61000.6-3 Safety ............................................<........................... ..... IEC62109-1(class II safety), UL1741................... ), UV Res.scant UL 9.. (.. VA Mater.... .......... ........................ ......................... .......................... ........... ..RoHS ........ Yes ............. - - - INSTALLATIOWSPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(WxLx.Hj .... ....................................... ......... 143 x 210 x.45 / 5.63 x 8.26 x 1.75 ..................................•450 mm/in ..8f Weight' / 1.0.................................. Iti. Input Connector ............... MG4 /Tyco / H+5 / Amphenol - H4 .................... ........ ........... Output Wire Type _ Double insulated TT ,_MC4 FL X Output Wire length .............. 0.95 / 3.0 . 0:95 / 3:0 12 % 3:9 I. .—..1..-.6../-.I 5:25 Operating Temperature Range..........I......I .....I_.................-40 -+65 / -40 :+150............................. .0 / �F... Protection Rating ....................................................................................... IP65 / NEMA4 ,. Relative Humidity 0-100 •.. , • % • R.aed St power of the-modale.. Mo&k of up to +A power toler+rwe WU wed. W W LLi PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V INVERTER Minimum String length (Power Optimizers) 8 8 18 ! MI. aximum String Length (Powl.er Optimizers) ............... ............25 ........... ............25 .................50........... ........ . Maximum Power per String .................................... ......... 5250.......................0. 600......................12750......... . W.... Power ... . . Parallel Strings of Different Lengths or Orientations Yes �l p��, �t�^�;.��� c�[�,�1,��vr.�-�.lr!?�•`"��e�C•—err, o ��r-vr•--r'�z www.solaredge.us Cep u.�±C(M1iYd7G 7f G� a �lLn c loC DQ SCFE �3Z DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. I N.T.S I PV-P6A I OPTIMIZER SHEET ECKLUND ROOFING INC Z W F O rn Q C4 C] LC) Z U.1 C'S �dU 0 C� C� I-_ 0 M 000 FL X U Q J 0 W7 Z = O to » p 4 U) j d U v ao rn o w � M Nm H OUB N W W LLi () , N N N L)WOwo 0 C0 co of J W W W LU Ll.l U U)F-(0 U) (Y U) U) U) U 00 V O W N L0 Lu ECKLUND ROOFING INC Z W F O Q C] LC) Z U.1 Z O ON Z) M o_ C� I-_ 0 M �}OU} FL X U Q J U Lu Z = O to » p 4 U) j d U v g v ECKLUND ROOFING INC W F Q Z O ON P:r; go FL X Lu U Z N tY O rn _ 0 0)o v g v Z_ Q U Nm H OUB N w v L)WOwo of C]NwZ � �zrn LU Ll.l Lu Go (Y U 00 V O ? L0 Lu Q W 12- 0- X O ECKLUND ROOFING INC fwd IRONRIDGE Ground, Mount System Mount ion a[1 terrains, In notime. The. IronRidge-Ground Mount System combines our Standard Rails (XRS) with locally -sourced steel pipes to create a cost-effectiV4 str1.ucture capable of handling any site or terrain challenge. Installation is simple with only a few structural components and no drilling, welding, or heavy machinery required. In -addition, the.system works with a variety of; foundation options; including concrete piers and driven piles. _ 360°. Product Tour 'Visit ironridge.com Substructure Top Caps Rail Connectors Diagonal Braces Schedule:40 Pipes ILL Connect vertical and horizontal pipes. Rail' Assembly Attach Rail Assembly to. Provide additional support Locally-sourced:pipes horizontal pipes. where required. serve as primary structure. w Standard Rails Top -Down Clamps Under Clamps Accessories Rugged Construction PE Certified OIL Engineered steel and aluminum Pre -stamped engineering letters $ �, y components ensure durability. available in most states. w _... _.. - — -- �� Simple Assembly Design Software Curved rails increase Secure modules to rails Akemative clamps for pre- Wire Clips and End Caps ' Just a few simple components ® Online tool generates engineering spanning capabilities. and substructure. attaching modules to rails. provide a finished look. and no heavy equipment values and bill of materials. • Resources Flexible Architecture 20 Year Warranty _ _ _ _ _ _ Design Assistant s NABCEP Certified Training C l Go from rough layout to fully QO Earn free continuing education credits, O o Multiple foundation and array Twice the protection offered by —_ engineered system. For free. while leaming more about our systems. configuration options. competitors.. Go to Ironridge.com/gm Go to Ir"onridge.com/training DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV -P7 RAILS SHEET ECKLUND ROOFING INC H Z 0 Z) tr U) CV CL Z W COQ wo 0 U)a- ' oo¢ w ' rn�UU Y 0W Y fn (� =o0cn» _co cn —OU .. a cn—a--10 U) CV r r r r 0 5 U Z U W W W U , N N N C') w LU X 0 w o � D H H H UN W Z) 0 � } >_ } N U7 U) Y) ECKLUND ROOFING INC H Z LU Z) tr U) Z W M } C W M oU)0 ' rn�UU Q of Y J Z a- w =o0cn» _co cn —OU LU a cn—a--10 ECKLUND ROOFING INC LU o� z o p N �o X LU U z N tr o U) 04 0 a) C7 C) 5 U Z U U) m O F O U I- N ov w LU X 0 w o � o f UN W Z) zrn U W W 00 D S g M Y _3 0 U w� U�Q2 ��� W a. a- X O F ECKLUND ROOFING INC 8431. Murphy Drive Middleton; WI 53562 USA Telephone: 608.636.4400 Facsimile: 608:831.9279 wvwv.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the samples) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. & Address: Product Description: Ratings & Principle Characteristics: Models: Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Number(s): This verification is part of ti imply product certification. IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA XR Rails with Integrated Grounding. Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications, with Typel, 2 and 3, listed photovoltaic modules.. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. 51-61GD-005, 51-61GD-0058, 51<5000-001 and 51-65-001 IronRidge Roof.Mount UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 08/27/2014 to 03/17/2015 301769343MID-001r1, 101769343MI0-001a, 101915978MID=001 & 101999492MID-001arl-c full test report(s) and should be read inconjunction with them. This report does not automatically Completed by: Chad Naggs Title: Signature: Technician -11.V Fire Resistance 16, Date: 03/30/2015 Reviewed by: Gregory Allen Title: Engineering Team Lead, Fire Resistance signature:G' Date: 03/30/ This Vedficarlon is for the exclusive use of Inrertek's client and is provided pursuant to the agreement between Interiek and Its Client- Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Clienr in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this veripcation. Any use of the Intertek name or one of Its marks for the sale or advertisement of the tested materia, product or service must first be approved In writing by Intertek The observations and test/laspection results referenced in this Verification are relevant only to the somple tested/inspected. This Verification by itself does not imply that the material, product; or service is orhos ever been under an Intertek certification program, GFT -OP -1 la (24 -MAR -2014) AUTHORIZATION TO MARK I . This authorizes the application of the Certification Markbelow s) shown e o to themodels described in the Product(s) Covered section when made in accordance with the conditions set forthJn the Certification Agreement and Listing Report. This authorization also applies to. multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The cert_ifcation mark(s) ma,y be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: 9495 Zephyr Ave . Address:: Hayward, CA 94544 Country: USA. Contact: Yann Schwarz Phone: (800)'227-9523 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Manufacturer: Precision Die & Stamping, Inc. Product: 1704.W: 10th Street Address: Tempe_, AZ 8.528_1 Country:. USA Contact: Andy Frola Phone. (480)' 967-2038 FAX: (480) 829=0838 Email: anoy@precisiondie.com Party Authorized To Apply Marc: Same as Manufacturer Report Issuing Office: Lake Forest; CA .Control Number: 4008083 Authorized by: for ETL CLASSIFIED' US OT Intertek Nice= M - -- 11 This document supersedes all previous Authorizations to Mark for the noted Report. Number. This Auaiorization tb Mark is for cite exclusive use of Interieks Client and is provided pursua t to ate CeitfllcaWn agreement Between intenek and its uttertelcs responsibility and 1Wbtilty are limited to the terms and conditions of the agreement Intettek assumes no liabnty to any parry, other than to the Client in attotdanee with the,agreemem, for any toss, expense or damage occasioned by the use of this Authortzation to Mark. Only the Ctlem is authorized to permit copying or distribution of this Authorization to Mair and then only In its,entirety, Use of Intertek's certification mark Is restricted to the conditions laid out In bre agreement and to this Authorization to Mark. Any further use of the attertek name for the sate or advertisement of (he tested material, product or service must first be approved In %riling by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the CertifiraWn marc In accordance %vb the agreement they are not for the purposes of production pualily control and do not relieve the Client of thew obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 66005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: XR Rails DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV-P7A RAILS CERTIFICATION SHEET M Z Zi W Z) IX CpCD U) cV � C] � Z uJ c0� F-dU 0 W Ur w a) M w DEQ w U) U U U)0 Q W F_Z< w =o0(n» W ooorno a v r> Z U' N r — N m � o0 U~N U) U.l LLI W U N N N Cn rn co w� 2 M 2 J� D HHH 0 >_>_>_ N rn U) rn ECKLUND ROOFING INC Z Zi W Z) IX U) C] � Z uJ Zo ON Z) M 0_ o Lo CN W Ur w a) M o}0 ce X U) U U Q W F_Z< w =o0(n» 0a) C) a —LQ cW0 ECKLUND ROOFING INC W Q O � Zo ON ao X W U Z N 0a) C) v v Z U' N m � o0 U~N OU w L) O Wwo o * N w D w af U c'7 YQ�O C7 WW U -Q2 Lu - aa Xo 1.- 1.0 ECKLUND ROOFING INC ,-+ o p gl m S 3 v a 3. a• ,� iu i� a b N b w'' a 'PI �3aT 44 b2 K � A• • b Q O b 7S4g4! !c n N �- c 7 CL T 3 a 3 Sm a �'b p D :1 y K z PV I U) z m w 9 Im � Y1L N A b 3 3 d 3 3 F � ��u K 9 p 7� f �°s �9 A s6.z 3T� g C <,g b �N} T C "� � - If• 5p S a S be. §� Q b A a �• a bR TE 6 3 3 N X8.7 ir r 3 b b rr at 3� O b � a wn r^ m � N nF d o �+ S n < Y � C a n m I - d b v" 3 � Z S 3 �Q b � 9 C � N. n 3 a. Q } w O — 3 R � 3 O p � 8 OI D w C S' f � g � b K° b?L fL c W 3 a a G 3 m F, d •D to :o o i co 0 3 v /a iv oI 2 t n W. ��' 3 5.c- 7 a Q'� a c a 7 O. n S must 9'�t° o O1'a c v M o SL 3o, v.7piOe gtna cAto�C a, od 9 to0 O`Ii�6 m a M.m� 'A 3 N m N ci : 'g ° o a o < : o a N c CL 6 p °. m N a o m a A H o �' '51. 3•m A �o ?gam »�O=o m Lu. go�� aN ?m:1 77 Igd �3 B 3 A 3• T � ^ '° � � r 3 EL M. O M N fp A d ^ IAN 3 N 3 ?� S� d� 30 v A T PROJECT: SMITH RESz 12.480 KW - DC GROUND MOUNT SOLAR SYSTEM 10 VISTA LAZO QUINTA CA, 92253 OCCUPANCY R3 /TYPE 5 STRU. �'b p D :1 y K z PV I U) z m w brs d < � Y1L N A b TATE LICENSE# 558389 O b b F � �3 a K p ■ �9 S. s6.z 3T� g C <,g b �N} T C "� � - If• 5p S a o o be. §� 3 m F, d •D to :o o i co 0 3 v /a iv oI 2 t n W. ��' 3 5.c- 7 a Q'� a c a 7 O. n S must 9'�t° o O1'a c v M o SL 3o, v.7piOe gtna cAto�C a, od 9 to0 O`Ii�6 m a M.m� 'A 3 N m N ci : 'g ° o a o < : o a N c CL 6 p °. m N a o m a A H o �' '51. 3•m A �o ?gam »�O=o m Lu. go�� aN ?m:1 77 Igd �3 B 3 A 3• T � ^ '° � � r 3 EL M. O M N fp A d ^ IAN 3 N 3 ?� S� d� 30 v A O. 0 C A d V W ,z C N 5. 91 -1 0* O (-PSL d�5's��Db v m 3= 7 A ]o fo 7 pj a n 3 a- g• c a w a to 7 C 8. =< S+ N SL ° p ;g SL r ry 2 h O a N N a d N IDN 7 a. _d d aaN B7 -c at CL °N ppmd. No o C 2 ° O O. N '^ '^ �o m 3 .^. Q. 7 m. 7 01 m fon Q 7 j: oaf a3.o _C w 9 A , ; N c ^ O N O C y N O = � - d �^' a t3 N PROJECT: SMITH RESz 12.480 KW - DC GROUND MOUNT SOLAR SYSTEM 10 VISTA LAZO QUINTA CA, 92253 OCCUPANCY R3 /TYPE 5 STRU. �'b p D :1 y K z PV I U) z m w J $ d O n < � Y1L N A b TATE LICENSE# 558389 A m o� F � �3 a a T 3 3 � a n m ■ o �To b � s6.z 3T� g 0 8 b �N} T C "� � - If• a �• a bR e c 3 N �g ir r O. 0 C A d V W ,z C N 5. 91 -1 0* O (-PSL d�5's��Db v m 3= 7 A ]o fo 7 pj a n 3 a- g• c a w a to 7 C 8. =< S+ N SL ° p ;g SL r ry 2 h O a N N a d N IDN 7 a. _d d aaN B7 -c at CL °N ppmd. No o C 2 ° O O. N '^ '^ �o m 3 .^. Q. 7 m. 7 01 m fon Q 7 j: oaf a3.o _C w 9 A , ; N c ^ O N O C y N O = � - d `�- S T O T 6• R si 0 m Z r z /z r� PROJECT: SMITH RESz 12.480 KW - DC GROUND MOUNT SOLAR SYSTEM 10 VISTA LAZO QUINTA CA, 92253 OCCUPANCY R3 /TYPE 5 STRU. � n ° D :1 y K z PV I U) z m w z --I 07 < y O TATE LICENSE# 558389 N Q C F � C qa a= 0 g 0 8 m n s o N W N% P G lz b ti u"i 4 b N �g b `�- S T O T 6• R si 0 m Z r z /z ECKLUND ROOFING INC 117 AREZZO CT. PALM DESERT, CA 92211 PHONE: 760-200-4001 XLA PROJECT: SMITH RESz 12.480 KW - DC GROUND MOUNT SOLAR SYSTEM 10 VISTA LAZO QUINTA CA, 92253 OCCUPANCY R3 /TYPE 5 STRU. 48 MODULES -CANADIAN SOLAR - CS6P-260M 2 INVERTERS - SOLAREDGE - SE6000A-US SYSTEM SIZE: 12.480 KW DC (STC) SYSTEM SIZE: 11.390 KW DC (PTC) SYSTEM SIZE: 11.106 KW AC (CEC) D :1 y K z PV I U) z m w z --I 07 < DOUG EXKLUND, CONTRACTOR TATE LICENSE# 558389 LICENSE CLASS B EXPIRATION DATE 07/31/2016 rM "il it 'o Washer, Electrical Equipment. Bond' WEEB INSTALLATION 'INSTRU.CTIONS lronRidgeIight ,&: Standard 'Series Rails Only 'Burndy recommends that tfi`e sufflchmUdetalls of the installation be `submitted #o the AHJ -for approval"before -Ah yWork is started. WEEBLug-6.7 WEEB-DMC WEEB Bonding Jumper -6.7 Products are tested to UL 467, CAN/CSA-C22.2 No. 41 US/ Canadian standards for safety grounding and bonding equipment. WiLey Document Number 104-0404-000039_-003HUF3BELL © 2012 BURN DY LLC. Page 1 of 14 SYSTEM OVERVIEW Use WEEB-DMC to:. bond -solar,module's to module mounting-raiL • electrically conned mechanically • -• Important notes Use one WEEBLug-6.7 assembly per rail to connect system to equipment ground conductor. 1. Use general purpose anti -seize compound on fastener threads when installing WEEBs. 2. The NEC section 690.43 states, "Exposed non:current carrying metal parts of module frames, equipment, and conductor enclosures shall be grounded in accordance with 250.134 or 250.136(A) regardless of voltage." 3. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. teki Document Number 104-0404-000039-003 © 2012 BURNDY LLC. Page 6 of 14 LAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the C or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. N.T.S I PV -P9 GROUNDING SHEET W o� Z 0 p N �o U � Z N F - Z vi Z 0 F- �� co U) CL D IO Z W CC d U 0 FW - .8 O Q w r0 ' UW) oww`�° Y< Z a- 5 o Z O W 8 88o "TC) D W Q_j N � . r r r U M Y O � W W W () , N N N ' U) U) Cf) w W2 W2 1 w0 D~ F - F - H 0� >->->- 2 W N U)U)U) W o� Z 0 p N �o U � Z N F - Z vi Z 0 F- v U) z Q U D IO Z W Lm Z) M a CLD FW - L) wOVA r0 ' UW) oww`�° Y< Z a- W��Ocn» Z O W v�>C1U ai-a-_j0 t) W o� Z 0 p N �o U � Z N � O vi _ C� °' o v v z Q U Lm LL O V N L) LU oww`�° N w Z W D W Q_j U M Y O U wto U) w a a X o ECKLUND ROOFING INC GENERALNOTES 2013 CEC, 2011 NEC, LAFD-MARKINGS, LABELS, AND WARNING SIGNS REQUIRED A. Main Service Disconnect: CAUTION SOLAR ELECTRIC SYSTEM CONNECTED 1. Residential buildings - the marking may be placed within the main service disconnect. The marking shall be placed on the outside cover if the main service disconnect is operable with the service panel closed. 2. Permanent labels shall be provided , no sharpie marking will be allowed within any main service panel or subpanel. 3.AII National Electric Code, and Fire Department required labeling will be made of sunlight and weather -resistant material. Labeling on disconnects, inverters and service panels will be made of an engraved, plastic material.and be permanently attached to its respective device. All labeling shall be attached directly to those pieces of equipment. 4.Markings: Verbiage, Format, and Type of Material. a. Verbiage: WARNING POWER TO THIS BUILDING IS ALSO SUPPLIED BY PHOTOVOLTAIC SOLAR SYSTEM, DO NOT TOUCH TERMINALS b. Format: (1) White lettering on a red background. (2) Minimum 3/8 inches letter height. (3) All letters shall be capitalized. (4) Arial or similar font, Non -bold (5) Reflective weather resistant material suitable for the enviromerit (durable adhesive materials must meet this requirement) B. Marking Requirements on DC Conduit. Raceways, Enclosures, Cable Assemblies, DC Combiners, and junction boxes: 1. Markings: Placement, Verbiage, Format, and Type of Material. a. Permanent Placement: Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and/or below penetrations, all DC combiners, and junction boxes. b. Verbiage: CAUTION SOLAR CIRCUIT c. The following label to be placed on all AC disconnects CAUTION SOLAR CIRCUIT DISCONNECT NEAR GROUND -FAULT INDICATOR STRING INVERTERS ONLY (Art. 690.5 (C) CEC) PLACED ON MAIN ELECTRICAL PANEL PLACED ON MAIN PANEL ADJACENT TO THE PV BREAKER(S). (CEC 690.64 B 7) PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES, AND DISCONNECTS. MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET (3048MM), WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS.CFC 604.11.1& CRC R331.2 PLACED ON SERVICE ENTRANCE PLACED ON EACH DC DISCONNECT INVERTER 690.54 PLACED ON AC DISCONNECT ON ALL DC CONDUITS RACEWAY EVERY 10'& "J" BOX PLACED ON MAIN PANEL N.T.S PV -P10 WARNING LABELS DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. H Z LU C0 N Cn o `r' Z W Z o 0Q U)d0 tcc0 o ...." U ' w ooQ oCD 0 cn U)�UV N Y Y Y O w LU ch o: O D N c W � M U N r r r T O N N ti Oo OV~0 U N z � U)07U) c� � � www �Owo W� o �U) x 0 U) U) W D X Z Q _J U)U)U) U� Zi 00 N DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. H Z LU C0 Q o(D o `r' Z W Z o 0Q D M a. U.)� I.— rnM U) oCD 0 cn U)�UV Q iog~Za LOcn>> LU p 1=roU) jCd0 o: O W WW (Ld g0 DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing, of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them. ECKLUND ROOFING INC LU Q o(D Z o 0Q Q � oCD 0 a X LU Z o: O N c v U ZQI U Em ti Oo OV~0 z � N c� _ �Owo W� o �U) x D X Z Q _J WC9 U� Zi 00 Y O wL0 L) aa U) X_0 ECKLUND ROOFING INC O^^ CD M CD d — On °3 d m o o a v y 0. O N CD � < Cv CD CC) N CD' C co) S O O O a CS O "N -w 7 O N AN CD O � CD CD H 2 = m a c @ a 67 ie n co cr _N (=j N N_ 'u co O C7 o� CID N 0 0 RL o =T( 08 CD CD 0 cA C. � C N a C-) cn O CCD 0 0 9. CD Z3 aCD N n o O=3Lff N CS n O N E5: S CD N � N O M CD Ln O U3 CL =. N � 7 (D n- O N � N N OO O_ 9 _3 CD N. O N. O N O N � O . L1 yN � O CD 7 8 .NF P CD n CD 5* EF co d =r Ep CID CD0 CD CD O C cam ca O ;a cn n ;o m cn mv Foll C m cn r r m n 2 m Jv i OJ Ti i m cn m �v n m m jo C m Z V n O CX O cm O O =" cn CD n' CD CD N ECKLUND ROOFING INC 48 MODULES -CANADIAN SOLAR - CS6P-260M O m 117 AREZZO CT. PROJECT: 2 INVERTERS - SOLAREDGE - SE6000A-US z PALM DESERT, CA 92211 PHONE: 760-200-4001 SMITH RES SYSTEM SIZE: 12.480 KW DC (STC) Z r 12.480 KW - DC GROUND MOUNT SYSTEM SIZE: 11.390 KW DC (PTC) 0 G) PV SOLAR SYSTEM SYSTEM SIZE: 11.106 KW AC (CEC) a z X 10 VISTA LAZO z LA QUINTA CA, 92253 < ^ DOUG EX IdUND, CONTRACTOR OCCUPANCY R3 / TYPE 5 STRU. TATE LICENSE# LICENSE CLASS DATE 558389 B JEXPIRATION 07/31/2016 N