Loading...
BMCH2016-002478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T44-4Q91A& COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O16-0024 Property Address: 45200 WASHINGTON ST ST APN: 604630014 Application Description: HOMEWOOD SUITES / CHANGE OUT (2) HEAT PUMPS Property Zoning: Z Application Valuation: $6,395.00 Applicant: a Q, IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 • LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 489046 Date: Z )O le Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, -also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: 11111111111111111111 24 VOICE (760).777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date Owner: L Q HOSPITALITY 77564 COUNTRY CLUB DR 100 PALM DESERT, CA 92253 -- 2/10/2016 J WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance.of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Z i0 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of la Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property forinspection purposes. Date: 10 Signature (Applicant or Agent).- Lender's gent): n o t Contractor: `-�� ESSER SERVICES INC DBA q19 IRO P 0 BOX 1636 Z CATHEDRAL CITY, CA 9223 ry —' o a Q, (760)324-0550 Llc. No.: 489046 2/10/2016 J WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance.of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Z i0 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of la Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property forinspection purposes. Date: 10 Signature (Applicant or Agent).- Lender's gent): FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD. RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00. $0.00 DESCRIPTION ACCOUNT QTY AMOUNT :PAID. PAID DATE HVAC CHANGEOUT - FURNACE ONLY 101-0000-42402 0 $72.52 $0.00 PAID BY METHOD RECEIPT # CHECK# CLTD BY DESCRIPTION 'ACCOUNT QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - FURNACE ONLY PC 101-0000-42600 0 $48.34 $0.00 -PAID BY METHOD RECEIPT #. CHECK # CLTD BY Total Paid for CHANGEOUT: $120.86 $0.00 DESCRIPTION ACCOUNT: QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 Permit Details : PERMIT NUMBER City of La Quinta BMCH2B1�60024 Description: HOMEWOOD SUITES / CHANGE OUT (2) HEAT PUMPS Type: MECHANICAL Subtype: Status: APPROVED Applied: 2/10/2016 SKH Approved: 2/10/2016 SKH Parcel No: 604630014 Site Address: 45200 WASHINGTON ST ST LA QUINTA,CA 92253 Subdivision: PM 31116 Block: Lot: 4 Issued: Lot Sq Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $6,395.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 NAME TYPE Details: HVAC CHANGE OUT- (2) HEAT PUMPS [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT IE INC 31225 LA BAYA WESTLAKE VILLAGE CA 91362 CONTRACTOR ESSER SERVICES INC DBA ESSER AIR CONDITI P 0 BOX 1636 CATHEDRAL CITY CA 92235 OWNER L Q HOSPITALITY 77564 COUNTRY CLUB DR 100 PALM DESERT CA 92253 ` FINANCIAL INFORMATION Printed: Wednesday, February 10, 2016 1:48:33 PM 1 of 2 0 SYS TEARS •PERMIT NUMBER Permit Details City of La Quinta BMCHy20416=0024 rig - - - - - -------------- CBY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0. $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: HVAC CHANGEOUT - 101-0000-42402 0 $72.52 $0.00 FURNACE ONLY HVAC CHANGEOUT - 101-0000-42600 0 $48.34 $0.00 FURNACE ONLY PC Total Paid for CHANGEOUT: $120.86 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• 00 PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS77 REMARKS NOTES DATE Printed: Wednesday, February 10, 2016 1:48:33 PM 2 of 2 r SYSTEMS slrt. # Qt}/ Of La QUI n' to Bull&8i: Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Budding Permit Application' and Tracking Sheet Permit # Project Address: 45200 Washington Street. Owner's Name:. Homewood Suites, Richard Levine A. P. Number. Address: 45200 Washington Street Legal Description: City, ST, Zip: La Quinta, CA :92253 Contractor: Esser Services Inc q Telephone: 760-391-4600 Address: PO Box 1636 Project Description: Replace (2) 2ton Heat Pumps City, ST, Zip: Cathedral City, CA 92235 Telephone: 760-324-0550 State Lic. 4: t4 $gC1,4 , City Lic. 9, Arch., Engr., Designer. Address: City., ST, Zip: Telephoner .Y ". . ; > .:' State Lic. #:,�'"c ;^::��;y:%i���,'. � Construction Type: , Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Steven Schnierer Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 818-735-7876 Estimated Value of Project: $6,395.00 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact Person Plan Check Balance • Title 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctionstissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"` Review; ready for correctionsAssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Bin. # Qty. Of La QUfi1ta Building 8i' Safety Division P.O. Box 1504,•78-495 Calle Tampico U •Quanta, CA 92253 -:(760) 777-7012 Z Building Permit Application and Tracking Sheet Permit # 12� kUi12D1 i Project Address: 45200 Washington Street , Owner's Name:. Homewood Suites, Richard Levine A. P. Number: Address'. 45200 Washington Street Legal Description: Contractor: Esser Services Inc City, ST, Zip: La Quints, CA '92253' to gr - Telephone: 760-391-4600 Address: PO Box 1636 Project Description: Replace (2) 2ton Heat Pumps City, ST, Zip: Cathedral City, CA 92235 Telephone: 760-324-0550 City Lia #•: State Lie. # : Arch., Engr., Designer: Address: City., ST, Zip: Telephone: P .� State Lie. #: r .��'V,� Name of Coateet Person: Steven Schnierer Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Unitp: Telephone # of Contact Person: 818-735-7876 Estimated Value of Project: $6,395.0q APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plgn Sets Plan Check submitted Item Amount Structural Ca[cs. Reviewed, ready for corrections Plan Check Deposit. . Truss Cales. Called Contact Person Plan Check Balance. Title 24 Cates. Pians picked up Construction Flood plain plan Plans resubmitted.. Meeharilcal Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Caned Contact Person Plumbing Grant Deed Plans picked up S.MX H.O.A. Approval Plans resubmitted Grading IN ROUSE:- 34 Review; ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees STATE OF CALIFORNIA - ALTERATIONS - HVAC CEC-CFIR-ALT-04-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CFIR-ALT-04-E Alterations - HVAC CZ 2, and 8-15 (formerly CF -1R -ALT -HVAC) (Page 1 of 1) Site Address: Enforcement Agency: Dat Pre ared: Permit#: 5zo0 C Jocsl.:Y� fioY, S�'- C, L� v;r� z 10 I Equipment Type Equipment Efficiency New Ducting, Plenums, Lineset: Conditioned Thermostat Required R -value Floor Area (sq ft) ❑ Packaged System Evaporator Coil AFUE COP ❑ R-6 (CZ 2, 8-13) Ducting Served by system Setback ❑ Split System ❑ Condensing Unit ❑ R-8' (CZ 11, 14, 15) Ducting sgft (If not already ❑ Mini Split ❑ Compressor I9 SEER 7-) HSPF ❑ R-6 (all CZ's) Plenums present, must j8(Furnace ❑ Lineset ❑ R-5 or R7.5) Lineset` be installed) ❑ TXV EER HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand: For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CF111-ALT-02-E Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23.or 24)2 -HERS, MECH-2S-HERS2 Compressor, TXV, Lineset, CF3R: MECH-20-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS' Air Handler/Furnace2 (Can include new ducting) Installer Requirement: Duct leakage (:L15%, or < 10% to outside, or seal all accessible leaks), Air Flow Z 300 CFM/ton, Refrigerant Charge. Exempted from duct leakage testing if: ❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building ....... ❑ 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts' CF111-ALT-02-E including Mini Split CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS2 CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERSZ, MECH-25-HERSZ Mini Splits require CF111-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS Installer Requirement: Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge ❑ 3. All New Ducts with Replacement Required Compliance Documents to be left on site for Final: All New Ducts' and one or more of the following CF111-ALT-02-E replaced: Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Compressor, TXV, Lineset, Furnace2 CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Installer Requirement: Duct leakage < 6%, Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts' I CF111-ALT-02-E, CF2R: MECH-20-HERS, CF3R: MECH-20-HERS Installer Required to: Duct leakage L15% or, < 10% to outside or, or seal all accessible leaks) ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. 'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc. 2 Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25 ' All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) ` R-5 (1" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter with insulation as the following 1.5-2T-2%", 2.5 -3T -2W, 3.5 to 4T-2%", 5T -4Y." Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. 5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable• compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsibly Designer Signature: Dat Signed: License: csvn���� �eC r Z IO lCe L4a9041 C mpany: Address: O fox I (0 3 (o City/State/Zip: �.�1. C. 4 25 Phone: �c=o -32�+ c�sso For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: '1-800-772-3300 STATE OF CALIFORNIA ' ALTERATIONS - HVAC CEC-CF1 R -ALT -04-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-04-E Alterations - HVAC CZ 2, and 8-15 (formerly CF -1R -ALT -HVAC) (Page 1 of 1) Site Address: Enforcement Agency: Dat Pre ared: Permit#: ' \ LjSZ.CX2 �. Cidk � L. Z2 w 0.Sk')Y1 rL i c, 10 l Equipment Type Equipment Efficiency New Ducting, Plenums, Lineset: Conditioned Thermostat Required R -value Floor Area (sq ft) ❑ Packaged System )'Evaporator Coil AFUE COP ❑ R-6 (CZ 2, 8-13) Ducting Served by system Setback ❑ Split System ❑ Condensing Unit ❑ R-8' (CZ 11, 14, 15) Ducting sqft (If not already ❑ Mini Split ❑ Compressor ]SEER HSPF ❑ R-6 (all CZ's) Plenums present must (Furnace ❑ Lineset EER ❑ R-5 or R7.5) Lineset° be installed) ❑ TXV HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered (no'hand filled forms allowed) and a copy left on site. 1. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CF111-ALT-02-E Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)2 -HERS, MECH-25-HERS2 Compressor, TXV, Lineset, CF3R: MECH-20-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS2 Air Handler/Furnace' (Can include new ducting) Installer Requirement: Duct leakage (< IS%, or < 10% to outside, or seal all accessible leaks), Air Flow t 300 CFM/ton, Refrigerant Charge. Exempted from duct leakage testing if: ❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or• ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building ....... ❑ 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts3 CF1R-ALT-02-E including Mini Split CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS' CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS2 Mini Splits require CF111-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS Installer Requirement: Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge 03 . 3. All New Ducts with Replacement Required Compliance Documents to be left on site for Final: All New Ducts' and one or more of the following CF111-ALT-02-E replaced: Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Compressor, TXV, Lineset, Furnace CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Installer Requirement: Duct leakage < 6%, Air Flow z 350 CFM/ton (or alternative), Refrigerant Charge Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts' CF1R-ALT-02-E, CF2R: MECH-20-HERS, CF3R: MECH-20-HERS Installer Required to: Duct leakage (< 15% or, < 10% to outside or, or seal all accessible leaks) ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. 'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc. ' Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25 ' All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) ` R-5 (1" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter with insulation as the following 1.5-2T-2%", 2.5-3T-2'/<", 3.5 to 4T -2%a', 5T -4'/e' Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. S. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on.other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Date igne Lcense: - to ( ygg,f ,OTo Company: �sSe�Sec v�ccs 5,,.�. Address:. 1::10 Sox City/$tate/Zip: Phone:. --too-3Z4- oss For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1=800-772-3300