BRES2015-045078-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BRES2015-0450
Property Address:
80435 WEISKOPF
APN:
762090011
Application Description:
BLACK / REMODEL BATH
Property Zoning:
Application Valuation:
$200,000.00
Applicant:
BLACK FAMILY TRUST
80435 WEISKOPF
LA QUINTA, CA 92253
mud 4 44wfw
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 7774011
INSPECTIONS (760) 777-7153
I IIIIII II"I IIII IIII Owner:
11 KENNETH BLACK & KA TRUST
57630 BALLYBUNION
A. KITHCEN, WINDOWS, LIGHTING LA QUINTA, CA 92253
® A � 0
DEC 17 201 Contractor:
OWNER BUILDER
CITY 0.= LA QUINTA
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: _ License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
bas' ` for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
pe i ubjects the applicant to a civil penalty of not more than five hundred dollars
r"OZ.M4
)•:
I, as owner of the property, or my employees with wages as their sole
ensation,will do the work, and the structure is not intended or offered for sale.
.7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
areof intended or offered for sale. If, however, the building or improvement is sold
wit n one year of completion, the owner -builder will have the burden of proving that
heAr she did not build or improve for the purpose of sale.).
as owner of the property, am exclusively contracting with licensed contractors
construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State icense Law does not apply to an owner of property who builds or improves
they o , and who contracts for the projects with a contractor(s) licensed pursuant to
th ontractors' State License Law.).
I am exempt under Sec. , B.&P.C.j6r this reason
Date:
f�i�TRUCTIONDING AGENCY
I hereby affirm under al 7of perjuryt at there is a construction lending agency for
the performance of h� ork for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Add
Lic. No.:
Date: 12/17/2015
WORKER'S COMPENSATION DECLARATION
1 hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Polity Number:
1 certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:
Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
A�t issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state law elating to building
construction, and hereby authorize representatives of this city t enter upon the
above-mentio ed Pr"erty for inspection purposes.
Date: Signature (Applicant e
x
IDE ' Y ACONT QTY AMO NT. A U ,:kPAID �A E
°,BSl45:5$3473"FEE 101-000020306. ".
0
$8:00~' $8.00. 12J17j15
Sk 101111b f�.�AF�D BY h 4.. ET OD �,
K RIPT # CHEC _ Ya
KENNETH BLACK & KATRUST CHECK:
R11606 1119 SGU
Total Paid for'BUILDING STANDARDS ADMINISTRATION BSA: $8.00 $8.60.
`DESCRIPTION
�ACGOUNT
QTY
,AMOUNT
PAID
PAID�DATE
RESIDENTIAL,_ EA ADDITION 1,0005F
101-0000-42403
0 _
$36.99
'$36.99
12/17/15
� ID'BY , '
yMET�H�OD�_
RE T
W' CK #
CLTU BY
KENNETH BLACK & KA TRUST
CHECK
R11606
-1119
SGU
sA SCRIPTION
A COUNT
:QTY
AMOUNT,
PAID
P�AIDDATE
RESIDENTIAL, EA ADDITION'1,000SF,'PC
101-0000-42600
0
$15.24
$15.24
12/17/15
��
��
R C INT#a ...E
C ECK #
,.
CLTD Blf
KENNETH BLACK & KA TRUST,
CI4ECK
R11606
1119
.:SGU
�� j DES RIPTION �..
AUN
QT;Y
AMOUNTq
p
�p�Dx'p
'RESIDENTIAL, FIRST 1,000SF
101:0000=42403.
�
0
$145.03
$145.03 .'
11/17%15
! $ {� -. L."5 •'X'T >T 4. 413 '>+-5 &�. �4
'PAID BY
w,k. � .
�4 7}aSd�3'J�4r
�. r b
, .. ` METHOD. `, $
' �
> L RE N.
Nffl Kms#.
CLTDBY
:KENNETH BLACK & KA TRUST
` ' CHECK
R11606
1119
SGU
ham., 3DESCRI TION s
/1000UQTY
AMOUNT
PAID
%PAID E
RESIDENTIAL, FIRST 1,000SF, PC
101-0000=42600
0
$47.86
$41.86
'12/17/15"
R�101
onMETHOD
RECEIPT#
CiiECK.# x
CL�TDrBY
'KENNETH BLACK & KA TRUST
CHECK .
R11606
1119
SGU
Total Paid•for;ELECTRICAL- NEW CONSTRUCTION: $245.12 $245.1-2.,
�5' 2 DESCRIP 1ON 'pry =
,.ACT"AMOUpNT
�a
Q..
ax
�'"D—,x
PAID> M
xP�AID>;D�ATE�
FIXTURE/TRAP
101-0000-42401
0
$169:26
$169.26"12/17/15'
X36.�e' � Ytt v .•r +' �qyx.. •4XY `Y yp`�4 � z'Y'... � �§ �
{ �,< � PAID776Y
�. •r^'n
ion HOD
�yr$�
RECEIPT #
"` .�`
C CK #
.
CLTD�6
KENNETH BLACK & KA TRUST
CHECK
R11606 _
1119'
SGU
5xDESCRIPTIONr
'SMr
,ACCON
.QTY ,
.4MONT .
A>pA
E
FIXTURE/TRAP PC
101-0000-42600
0 '.
$169:26
.$169.26
12/17/15
�.;s �y,sy�P`AIDBY�
§y:.h}N`.C._yx%��"�;.�i�„,,..::vk."A,+4.�
M HOD
... ..-
REC PT #
.. vaf.S:It.2 ....
CHECK It
x
CLTD`BY
KENNETH BLACK & KA TRUST
CHECK
R11606
1119
-SGU
Total Paid for PLUMBING FEES: - ; $338.52 $338.52.
rDESCRIP�TION,
ACCOUNT
AMOUNT
PAID b<
PADDATE
SMI - RESIDENTIAL
101-0000-20308
0
$26:00 ,
$26.00
12/17/15
PLAID B,Y°METHOD
.4 . N
a b s�
RCE PTz#
W e s
CHECK # -
� r
CLkTD'BY
� ,
KENNETH BLACK .& KA TRUST
CHECK
R11606
1119
SGU
Total Paid for STRONG, MOTION INSTRUMENTATION SMI: $26.00 $26.00
DESCRIPTION
y
A` OU T
�.-.
TY ;
�:;
AMO �T rlop
�M.
PAID
PA D DATE
DOOR/WINDOW, REPLACE FIRST 7.
101-0000=42400,
6'
"$60.91
$60.91
12/17/15
,PAID,BY
.. .:. � a
Al ; ME H
T # �
y CHECK#
;CCTD; le
KENNETH BLACK &•KA TRUST
CHECK
1111606
1119
SGU
a D�E.,SGRIPIO
dCU
4
AMUN
PAIDi
vu
PAI'DO
DOOyR/WINDOW, REPLACE, EA ADDITIONS
101-0000-42400
0.
$10:15
$10:15;
12/17/15
:� "r�*���Atii��f* ��
METHODSRECEIPT#
a��.s2
��CHECK#
5.`1�.k'' ✓...�''h 4x:`.*%
CLTp Blf
ti
„
,, ,...k;+.i.. 3nFtw,r'7:
N.<e+.`a
KENNETH BLACK & KA TRUST
CHECK "
'R11606
1119
SGU
.k. iC ':S f )S I✓NY 'iu M'f'.n" <Yy,fya�� �Y {�.
4. , ai'h``.., xII ,CSS
ACCQUNT�..19T,
Zr
+Ki( LL
PAI'
'�a',4ob`?ss y.. 'i .:•av
DAT
,rh :� t ,DESCRIPTION
JY
.:.
LAID
DOOR/WINDOW, REPLACE, EA ADDITION 5
101-0000-42600
0.
$11.60
$11.60
12/17/15
PC
�
EC4D
X4w
w kChL'v1T, Dk '
BYEC
.'>F.':.
e
KENNETH BLACK & KA TRUST
CHECK
R11606
1119
SGU
DESCRIP.TIONn;��
ACCOUNT
BAID x
PAID�DATE
.`
DOOR/WINDOW, REPLACE, FIRST 7 PC'
101-0000-42600
0
$110.22
$110.22
.12/17/15
PAID BY�.�
MHO�usx
m "`d `3*.cA�:�-.
RECEIj#
CHECK#CLTBY�
x�`iYf`L���n'-'.;.'7z'-
s. ,: z 3✓
,.
_
KENNETH BLACK & KA TRUST
CHECK
R11606
1119
SGU
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION:. ' $192.88 $192.88
•
Description: BLACK / REMODEL BATHROOM, KITHCEN, WINDOWS, LIGHTING
Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED
Applied: 12/14/2015 SGU
Approved: 12/17/2015 JFU
Parcel No: 762090011 Site Address: 80435 WEISKOPF LA QUINTA,CA 92253
Subdivision: TR 28444 Block: Lot: 5
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $200,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
ANGELICA ZARCO
Details: INTERIOR REMODEL. REPLACE (8) WINDOWS/DOORS. REPLACE RECEPTACLES THROUGHOUT HOUSE AND INSTALL NEW
RECEPTACLES AT KITCHEN TO MATCH NEW CABINET LAYOUT. REPLACE EXISTING LIGHTING THROUGHOUT HOUSE WITH HIGH
EFFICACY LED FIXTURES. REMODEL (4) SHOWERS AND REPLACE (10) SINKS. 2013 BUILDING CODES.
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE .
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
NOTE
ANGELICA ZARCO
12/17/2015
12/17/2015
RECEIVED TITLE 24 SUBMITTAL
PLAN CHECK SUBMITTAL
STEPHANIE GUMPERT
12/14/2015
12/14/2015
RECEIVED
RESUBMITTAL
JAKE FUSON
12/17/2015
12/17/2015
REVISED TITLE 24 REPORT SUBMITTED VIA EMAIL.
NOTIFIED KEN BLACK (949-422-1877) THAT PLANS WOULD BE
TELEPHONE CALL
JAKE FUSON
12/17/2015
12/17/2015
READY FOR APPROVAL PENDING THE SUBMITTAL OF A
REVISED TITLE 24 REPORT.'
LEFT MESSAGE FOR JON SCOTT (ENERGY CONSULTANT) AT
TELEPHONE CALL
JAKE FUSON
12/17/2015
12/17/2015
760-200-4780 NOTIFYING HIM THAT THE ENERGY REPORT HE
PREPARED FOR THIS PROJECT DID NOT MATCH THE SCOPE OF
WORK AND WOULD NEED TO BE REVISED.
Printed: Thursday, December 17, 2015 4:03:36 PM 1 of 4 row— .........
CONDITION
DATE
DATE
DATE
PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY
BY
CONTACT
$8.00
12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU
STATUS
REMARKS
NOTES
TYPE
101-0006-42403
ADDED
REQUIRED
SATISFIED
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
_ SGU
ADDITION 1,000SF
CONTRACTOR REQUIRED PRIOR TO PERMIT
READY TO ISSUE
JAKE FUSON
12/17/2015
12/17/2015
101-0000-42600
COMPLETE
$15.24
ISSUANCE.
CHECKLIST
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
ADDITION 1,000SF, PC
TRUST
OWNER BUILDER AS CONTRACTOR
101-0000-42403
0
$145.03
CONTACTS
12/17/15
R11606
NAME TYPE
NAME
ADDRESSI
CITY
STATE ZIP PHONE FAX EMAIL
APPLICANT
BLACK FAMILY TRUST
80435 WEISKOPF
LA QUINTA
CA 92253
CONTRACTOR
OWNER BUILDER
TRUST
RESIDENTIAL, FIRST
101-0000-42600
OWNER
KENNETH BLACK .& KA TRUST 57630 BALLYBUNION
LA QUINTA
CA 92253
R11606
FINANCIAL INFORMATION
CLTD
DESCRIPTION ACCOUNT QTY AMOUNT
PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY
BY
BSAS SB1473 FEE 101-0000-20306 0 $8.00
$8.00
12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU
TRUST
Total Paid for BUILDING STANDARDS ADMINISTRATION
$8.00 $8.00
BSA:
RESIDENTIAL, EA
101-0006-42403
0
$36.99
$36.99
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
_ SGU
ADDITION 1,000SF
TRUST
RESIDENTIAL, EA
101-0000-42600
0
$15.24
$15.24
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
ADDITION 1,000SF, PC
TRUST
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$145.03
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
1,000SF
TRUST
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
1,000SF, PC
TRUST
Total Paid for ELECTRICAL- NEW CONSTRUCTION: $245.12 $245.12
FIXTURE/TRAP
101-0000-42401
0
$169.26
$169.26
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
TRUST
Printed: Thursday, December 17, 2015 4:03:36 PM 2 of 4 Arfirw ........
Printed: Thursday, December 17, 2015 4:03:36 PM 3 of 4 ICNWW_........
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
FIXTURE/TRAP PC
101-0000-42600
0
$169.26
$169.26
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
TRUST
Total Paid for PLUMBING FEES: $338.52 $338.52
SMI - RESIDENTIALT
0
I101-0000-20308 $26.00
$26.00
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
TRUST
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $26.00 $26.00
DOOR/WINDOW,
101-0000-42400
0
$60.91
$60.91
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
REPLACE FIRST 7
TRUST
DOOR/WINDOW,
REPLACE, EA ADDITION
101-0000-42400
0
$10.15
$10.15
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
TRUST
5
DOOR/WINDOW,
REPLACE, EA ADDITION
101-0000-42600
0
$11.60
$11.60
12/17/15
R11606
1119
CHECK
KENNETH BLACK & KA
SGU
TRUST
5 PC
DOOR/WINDOW,
101-0000-42600
0
$110.22
$110.22
12/17/15
R11606
1119
CHECK
K
KENNET & KA
SGU
REPLACE, FIRST 7 PC
TRUST
TRUST
Total Paid for WINDOW/SLIDING GLASS
$192.88 $192.88
DOOR/FENESTRATION:
TOTALS: $810.52 $810.52
Printed: Thursday, December 17, 2015 4:03:36 PM 3 of 4 ICNWW_........
2ND BLDG NS (1 I JAKE FUSON 112/17/2015 112/17/2015 112/17/2015 I APPROVED I I
WK)
BOND INFORMATION
Printed: Thursday, December 17, 2015 4:03:36 PM 4 of 4
Bin #/
I
City of La Quin to
Building 8t Safety Division'
78-495 Calle Tampico
j O La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
/
rr it
1.
roject Address:-� l' ,
Owner's Name•
P. Number: . gam'
Address: Zn,,:�;> S
Legal Description:
City, ST, Zip: LA, �' <
Contractor:.
r• o �
T h
ele one: z-
P
Address:
Project Description:
City, ST, Zip:
Telephone: e•
elePhn.
..
State Lic. # :
City Lic. #:
LP s.1
Arch., ];ngr., Designer:
Address:
r- F-- L �i
City, ST, Zip:
Telephone:
c
Occupancy:
•Co truction TYPe
State Lic. #.
Project (circlele ne)• New A dd'n Alter a a' Demo
Name of Contact Person: L&SE4
Sq. Ft.:,�
# Stories:
# Units:
K,-p:ho:ne # of Contact Person: 24h -
Estimated Value of Project: 2 ,
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Rcq'd
Rcc'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance.
Title 24 Cates.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Decd
Plans picked up
S.M.I.
II.O.A. Approval
flans resubmitted
Grading
IN ROUSE:-
''". Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
Schoch Fees,
Total Permit Fees
_q$
1 CITY OF LA QUINTA SUB-CONTAC , IS
JOB ADDRESS `f�5 �PERMIT NUMBER _OWNER ( L �„ SWLDER
This form shall be posted on the ioh with tie Building Inspection Card at all times in a conspicuous place, Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by aoolicant. "On File" is not an accentable resoonse.
Trade / Classification
Contractor
State Contractor's License
Workers Comp onsation Insurance-777r
City,Business License
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx)
Exp. Date
(xx/xx/xx)
EARTHWORK (C-12)
CONCRETE;(C:;81.: r
,
FRAMING (C-5),
ST.RUCT. STEEL (C-51),
MASONRY (C-29)
LATH, PIASTER (C-351,,.
DRYWALL (C-9) •
HVAC (Cr20) ..
i c
ROOFING (C-39)
SHEET METAL IC -43)''
FLOORING (C-15)
INSULATION (C=2)
SEWAGE'DISP: (G42)
PAINTING(C=3.3),
CERAMIC TILE,(C-6.4)
CABINETS (C-6). ;
FENCING (CJ21),
LANDSCAPING (C-271'
POOL (C-53)'
T-11dY 4 4 Qaha�
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a buildin ha ub�itted y me listing yourself as the builder of the property
improvements specified at
We are providing you with anOwner- udder Acknowl ent d Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
Read and initial each statement below to signify you understand or verify this information.
1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my roperty.
- 2. I understand building permits are not required to be signed by property owners unless they are responsible for the
conssf, o
on and are not hiring a licensed Contractor to assume this responsibility.
3. I understand as an "Owner -Builder" I am the responsible of record on the 't. I understand that I may protect
sP PAY 1�� Y
4. I �derstand Contractors are.required by law to be licensed and bonded in California and to list their license numbers on
perm t,�and contracts.
5. I unde stand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my co traction is at least five hundred dollars ($500), including labor and materials,•I may considered an "employer"
under to and federal law.
6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
co/7nderstand
n for each "employee." I also understand my failure to abide by these laws may subject me to serious -financial
ris
under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
8. I understand as an. Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
financial orders. nal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
w7,9understand
Kip or materials.
I may obtain -more information regarding my obligations as an "employer" from the Internal Revenue
Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.csib.ca.gov for more information about licensed contractors.
10.1 am aware of and consent o an Owner -Builder building permit applied for in my name, and understand that I am the
party le a fy jally �s onsi le � proposed co on activity at the following address:
t^
f 11. I aF-le-that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicabl aws and requirements that govern Owner -Builders as well as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors, may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those. Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permf�ote: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the ageW is reguired to be presented when the permit is issued to verify the property
owner's signature.
Signature of propertyowner Date:
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the -following -persons) -to -act as-my-agent(s)-to-apply-for-sign,-and-file-the-documents-tiecessary-to-obtain-an-Owner=Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license; form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature.
Property Owner's Signature: Date:
%A 4 �
`
See 1-S lc blf)e
4 Sins
4,,'s
A4e &t7A L4pgrqcleW 4()N_A ddllpl, 6liq ld� e- CS N o -TE)
,X15� 4q 51pp?
A -L (,i o 4 1>,,Y a W 4r) mvAe Icy box kck)ls,
MV.ST LIS 10
1,A
6Al2 A
Ren�ode,l L e, q ewd:
tj SlMk5
CAB
..........
%% Om ( 'a "
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE[7 �PIS BY
m
Al
wap L
RE
CEIVE®...___,
-DEC 14 2015
CITY OF LA n! qQ" 117A
COMMUNITY LEVL-_.l;4li',.iENT
y
•
�i
`o
_• d 1' s 7 ti. ; .t
pit; � • � -lea- C Iii•' " 4 !
4v Dy
• Cc��rFr t
� w
CITY ®F LAQUINTA
BUILDING & SAFETY DEPT, --- RECEIED
APPROVED,, DEC 142015
FOR CONSTRUCTION
CITY OF LA r11.91alT�
DATE- _BY COMMUNITY'
ty Li+Dii11.� d'e �0 Allo ' $
SIOZ 1 030 a Z
a3AI333H 0 o
1 el�l
Isv
• 7Rd
ca
.•j t I
CIP OF LA QUINTA
7, BUILDING & SAFETY DEPT.
APPROVED
F R
CONSTRUCTION .
DATE BY JF
izto
? I is tI
zo
it
36
AliNnWWOO
.10 V110 A113
5;011330 1
.4
CITY OF LA QUINT
BUILDING & SAFETY DEPT
APPROVED
FOR CONSTRUCTION
DATE BY
RE
I
m
ri
00
II
0:!
CL!
.4
CITY OF LA QUINT
BUILDING & SAFETY DEPT
APPROVED
FOR CONSTRUCTION
DATE BY
RE
I
m
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Black Residence
80-435 Weiskopf
La Quinta, CA 92253
Project Designer:
Chad McAfee
42-240 Green way STE G
Palm Desert, CA9260
(760) 578-6248
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
OFFi.c c "
F
F LAG &SAFETY DEPT.PROVED
IF
ONSTRUCTION
Job Number: DATEIZ / Za/,Gj13Y_
Date:
12/17/2015.
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standard's.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPro 6.7 Ty EnergySoft User Number. 6712 ID:
PiI J ,,u lr 'IV
i
�a� ..�.. •ice _ '�
V its ourrc t zvioll) flij
U
i
•
a
- TABLE OF CONTENTS.
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3.
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary ' 12
HVAC System Heating and Cooling. Loads Summary 16
Room Load Summary 17.
Room Heating Peak Loads 18
Room Cooling Peak Loads. 19
EnergyPro 6.7 by Energysoft
Job Number:
ID:
User Number. 6712
CERTIIQTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE (SHOD
Project Name: Black Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xmi
CO -PRF -01
Pagel of 8
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Black Residence
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ftz-yr)
03
Project Location 80-435 Weiskopf
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft) 3800
15
Number of Zones 1
16
Slab Area (ft) 3800
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (W) 0
21
Glazing Percentage (%) 31.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building Jincorporates one or more Special Features shown below.
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance 'Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-12-17 13:52:31 .
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftz-yr)
Standard Design
Proposed_Design
Compliance Margin
Percent Improvement
Space Heating
4.53
5.28
-0.75
-16.6%
Space Cooling
284.11
282.29
1.82
0.6%
IAQ Ventilation
0.00
0.00
0.00
'0.0%
Water Heating'
6.61
6.50
0.11
1.7%
Photovoltaic Offset
—
0.00
0.00
--
Compliance Energy Total
295.25
294.07
1.18
0.4%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance 'Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-12-17 13:52:31 .
CERTINTE OF COMPLIANCE - RESIDENTIAL 'PERFORMANCE COMPLIANCE *OD
Project Name: Black Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
HERS FEATURE SUMMARY
CIRPRF-01
Page 2 of 8
The following is a summary of the features that must be field -verified, by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• — None --
Cooling System Verifications:
• — None --
HVAC Distribution System Verifications:
• — None --
Domestic Hot Water System Verifications:
• — None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an r
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)" 334.38 333.20 1.18 0.4%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Black Residence
3800
1
3
1
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone•Name
Zone Type
HVAC System Name
Zone Floor Area
(ft')
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
residence
Conditioned
HVAC1
3800
9
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 13:52:31
=ORMANCE COMPLIANCE #06
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xm1
CO -PRF -01
Page 3 of 8
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
03
04
05
06
07
08
09
10
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (tt2)
Tilt
'(deg)
Status
Verified
Existing
Condition
R-13 Wall
0
Right
862
292.5
90
Existing
No
R-13 Wall
90
Front
1010
137.2
90
Existing
No
R-13 Wall
180
Left
862
280.2
90
Existing
No
R-13 Wall
270
Back
1010
489.1
90
Existing
No
Defaul: 1978 to present
3800Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
03
04
05
06
Type
Roof Rise
Roof Reflectance
Roof Emittance
Ventilated
3
0.1
0.85
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
SIDENTIAL PERFORMANCE COMPLIANCE SOD
/sis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xml
COPRF-01
Page 4 of 8
WINDOWS
01
02
03 04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Multiplie
Width(ft) Height (ft) r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
existing
N Wail ex (Right -0)
- - 1
30.6
0.71
0.60
Insect Screen (default)
Existing
No
existing 2
N Wall ex (Right -0)
- - 1
54.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 3
N Wall ex (Right -0)
- - 1
27.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 4
N Wall ex (Right -0)
- - 1
26.4
0.71
0.60
Insect Screen (default)
Existing
No
existing 5
N Wall ex (Right -0)
- - 1
16.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 6
N Wall ex (Right -0)
- - 1
4.0
0.71
0.60.
Insect Screen (default)
Existing
No
existing 7
N Wall ex (Right -0)
- - 1
4.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 8
N Wall ex (Right -0)
- - 1
4.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 9
N Wall ex (Right -0)
- - 1
4.0
0.71
0.60
Insect Screen (default)
Existing
No
existing'10
N Wall ex (Right -0)
- - 1
4.0
0.71
0.60
Insect Screen (default)
Existing
No
altered
N Wall ex (Right -0)
- - 1
21.6
0.54
0.24
Insect Screen (default)
Altered
N/A
altered 2
N Wall ex (Right -0)
- - 1
48.0
0.54
0.24
Insect Screen (default)
Altered
N/A
altered 3
N Wall ex (Right -0)
- - 1
21.6
0.54
0.24
Insect Screen (default)
Altered
N/A
existing 11
N Wall ex (Right -0)
- - 1
27.3
0.71
0.60
Insect Screen (default)
Existing
No
existing 12
E Wall ex (Front -90)
- - 1
13.7
"0.71
0.60
Insect Screen (default)
Existing
No
existing 13
E Wall ex (Front -90)
- - 1
14.0
0.71
0.60-
Insect Screen (default)
Existing
No
existing 14
E Wall ex (Front -90)
- - 1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 15
E Wall ex (Front -90)
- - 1
27.3
0.71
0.60
Insect Screen (default)
Existing
No
existing'16
E Wall ex (Front -90)
- - 1
17.1
0.71
0.60
Insect Screen (default)
Existing
No
existing 17
E Wall ex (Front -90)
- - 1
17.1
0.71
0.60
Insect Screen (default)
Existing
No
existing 18
S Wall ex (Left -180)
- - 1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 19
S Wall ex (Left -180)
- - 1
2.4
0.71
0.60
Insect Screen (default)
Existing
No
existing 20
S Wall ex (Left -180)
- --- 1
2.4
0.71
0.60
Insect Screen (default)
Existing
No
existing 21
S Wall ex (Left -180)
- - 1
8.4
0.71
0.60
Insect Screen (default)
Existing
No
existing 22
S Wail ex (Left -180)
- - 1
24.5
0.71
0.60'
Insect Screen (default)
Existing
No
existing 23
S Wall ex (Left -180)
- - 1
25.0
0.71
0.60
Insect Screen (default)
Existing
No
altered 4
S Wall ex (Left -180)
- - 1
22.4
0.54
0.24
Insect Screen (default)
Altered
N/A
altered'5
S Wall ex (Left -180)
- - 1
40.0
0.54
0.24
Insect Screen (default)
Altered
N/A
altered 6
S Wall ex (Left -180)
- - 1
22.5
0.54
0.24
Insect Screen (default)
Altered
N/A
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-12-17 13:52:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IVOD
Project Name: Black Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xmi
CO -PRF -01
Page 5 of 8
existing 24
S Wall ex (Left -180) -
- 1
54.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 25
S Wall ex (Left -180) -
- 1
30.6
0.71
0.60
Insect Screen (default)
Existing
No
existing 26
W Wall ex (Back -270) -
- 1
30.6
0.71
0.60
Insect Screen (default)
Existing
No
altered 7
W Wall ex (Back -270) -
- 1
54.0
0.54
0.24
Insect Screen (default)
Altered
N/A
existing 27
W Wall ex (Back -270) -
- 1
30.6
1 0.71
0.60
Insect Screen (default)
Existing
No
existing 28
W Wall ex (Back -270) -
-- 1
20.7
0.71
0.60
Insect Screen (default)
Existing
No
existing 29
W Wall ex (Back -270) -
-- 1
108.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 30
W Wall ex (Back -270) -
- 1
20.7
0.71
0.60
Insect Screen (default)
Existing
No
existing 31
W Wall ex (Back -270) -
- 1
4.0
0.71
0.60
Insect Screen (default)
Existing
No
altered 8
W Wall ex (Back -270) -
- 1 "
54.0
0.54
0.24
Insect Screen (default)
Altered
N/A
existing 32
W Wall ex (Back -270) -
- 1
54.0
0.71
0.60
Insect Screen (default)
Existing
No
existing 33
W Wall ex (Back -270) -
- 1
54.0
0.71
0.60
Insect Screen (default)
Existing
No
existing•34
W Wall ex (Back -270) -
- 1
58.5
0.71
0.60
Insect Screen (default)
Existing
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09 .
Name
Zone
Total Cavity
Winter "Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
186
None
0.8
No
Existing
No
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofresidence
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below .
Cavity %Frame: R-9.1 /2x4
Defaul: 1978 to present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 11
0.083
Over Floor Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
06
06
07
08
09 .
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
residence
3800
186
None
0.8
No
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 13:52:31
CERTIQTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE N*OD
Project Name: Black Residence
.Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xrhl
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required —
CRF -01
Page 6of8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
1
Cooling
Yes
Air Distribution
HVAC Fan
3800
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC -'HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-12-17 13:52:31
CERTATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE AOD
Project Name: Black Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xml
APRF-01
Page 7 of 8
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Verified Duct Location
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12No
Duct Leakage
No
N/A
Location
system
Status'
Condition -
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
.04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
.Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status'
Condition -
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
COOLING VENTILATION
01 02 03 04
Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
VVH Fan 1 61 0.52459 1
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-12-17 13:52:31
CERTATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE AOD
Project Name: Black Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:51, Thu, Dec 17, 2015
Input File Name: Black Res -Chad McAfee-15.xml
T
CO -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
12/17/2015.
Address:.
CEA/HERS Certification Identification (If applicable):
77-085 Michigan Drive
City/State!-81•m Desert, CA 92211
I'
Phone:
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, .
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Chad McAfee
Company:
Date Signed:
Chad McAfee
Address:
License:
42-240 Green way STE G
City/State/Zip:
Phone:
Palm Desert, CA 9260
(760) 578-6248
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-12-17 13:52:31
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Black Residence
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
12/17/2015
Project Address
80-435 Weiskopf La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,800
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavi (ft) Special Features Status
Roof Wood Framed Attic R11 3,800 Existing
Wall Wood Framed R 13 2,545 Existing
Slab Unheated Slab -on -Grade no insulation 3,800 Perim = 186' Existing
Demising Wood Framed R 13 511 New
FENESTRATION I Total Area: 1,199 Glazing Percentage: '31.6 % New/Altered Average U -Factor: 0.54
Orientation Area(ft). U -Fac SHGC Overhang Sidefins, Exterior Shades Status
Right (N) 201.3 0.710
0.60 none none Bug Screen Existing
Right (N) 91.2 0.540
0.24 none none Bug Screen Altered
Front (E) 137.2 0.710
0.60 none none Bug Screen Existing
Left (S) 195.3 0.710
0.60 none none Bug Screen Existing
Left (S) 84.9 0.540
0.24 none none Bug Screen Altered
Rear (W) 381:1 0.710
0.60 none none Bug Screen Existing
Rear (IM 108.0 0.540
0.24 none none Bug Screen Altered
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
3 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 6.7 by EnemySoft User Number.' 6712
Runcode: 2015-12-17713:52:57 ID:
Pae 11 of 23
•
•
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of. § 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§I 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110 8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(6):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-] 9 in 2x6 or 0.074 maximum U -
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
§150.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption late, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater. than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets therequirements of § 110.8( .
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)]A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ I50.0(e)] B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)] A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)]B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recireulation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A
[§150.06)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
•
•
2013 Low -Rise Residential Mandatory Measures Summary
§150.0(j)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space. shall have a Class I
§150.06)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class l or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or 1V vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §110.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct-closure'system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %< inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be corn ressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: piessure-sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)]A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
•
•
2013 Low -Rise Residential Mandatory Measures Summary
110.4(b)l :
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ I I0.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specifiedpump* sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)]A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)l B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ I50.0(k)1 D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)l F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ I50.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if. it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §I50.0(k)2.
§ 150.0(k)3•A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook area's, are
considered kitchen lighting if they are not.se arately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages; laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch thatdisables the motion sensor, or controlled by. a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
•
•
0
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, 130.4, §140.7 and §141.0.
§I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9, 130.0, §130.2, §130.4, §140.7 and 141.0.
§ 150.0(k)9D:
Outdoor lighting.for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with theapplicable requirements in 110.9, 130.0, 130.2, 130.4, §140.7 and 141.0. '
§ I50.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 13 0.0 c .
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, §130.0, §130.1, 130.4, 140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ I 50.0(k) I 2B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l :
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 through 110.10 e .
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke '
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 ercent'of the total roof area of the buildin � excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§I 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solarelectric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder -location or
main circuit location, and permanently marked as "For Future Solar Electric".
•
•
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Black Residence
12/17/2015
System Name
Floor Area
HVAC
3,800
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
Total Room Loads
-Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING
CFM Sensible
7,106 99,205
0
8,412
0
570 24,336
0
8,412
1 140,365
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output per System 89,000
5,428 1,401
76,361
Total Output Btuh 267,000
Output Btuh/s ft 70.3
5,425
Cooling System
0
Output per System 35,500
3,966 570
27,168
Total Output Btuh 106,500
9,393
0
Total Output Tons 8.9
5,425
Total Output Btuh/s ft 28.0
Total Output s ft/Ton 428.2
114,379
Air System
CFM per System
1,400
HVAC EQUIPMENT SELECTION
Airflow cfm
4,200
Existing HVAC
67,045
30,239
267,000
Airflow cfm15 ft
1.11
Airflow cfm/Ton
473.2
Outside Air %
13.6%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
67,045
30,239 267,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.15
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 65 OF
65 OF 124 OF
O
�1'14.
Outside Air
570 cfm Supply Fan
Heating Coil
123 OF
4,200 cfm
�w
ROOM
71 of Return Fan
71 OF
72 OF
_[;�D
4,200 cfm
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 77/67°F 77/67°F 55/58°F
Outside Zr-
570 cfm
Supply Fan Cooling Coil
57 / 59 OF
4,200 cfm
72.6%
ROOM•
Return Fan
72/65°F
72/65°F
70/64°F
O
4,200 cfm
EnergyPro 6.7 by EnergySoft User Number 6712 Run Code: 2015-12-17713:52:57 ID:
Page 16 of 23
•
•
ROOM LOAD SUMMARY
Project Name Date
Black Residence 12/17/2015
System Name Floor Area
HVAC 3,800
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible Latent CFM Sensible
residence Black altered residence 1 7,1061 99,2051 5,428 7,1061 99,2051 5,4281 1,4011 76,361
PAGE TOTAL 1 7,106 99,205 5,428 1,401 76,361
• TOTAL' 7,106 99,205, 5,428 1,401 76,361
Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T13:52:57 ID: Pae 17 of 23
•
ROOM HEATING PEAK LOADS
Project Name
Date
Black Residence
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Black altered residence
Time of Peak
Jan 1 AM
Floor Area 3,800.0•ft2
Outdoor Dry Bulb Temperature
26 OF
Indoor Dry Bulb Temperature 72 OF
Conduction Area
U -Value AT *F
Btu/hr
Defaul: 1978 to present 3,800.0
X
0.0790 X
46 =
13,809
R-13 Wall 2,545.0
X
0.1020 X
46 =
11,941
Existing Window 914.9
X
0.7100 X
46 =
29,881
-LowE METAL .54.24 284.1
X
0.5400 X
46 =
7,057
Slab -On -Grade perim = 186.0
X
0.7300 X
46 =
6,246
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Items shown with an asterisk (`) denote conduction through an interior surface
to
another room
Page Total
68,934
Infiltration:[ 1.00 X 1.064 X 3,800 X
9.00
X 0.266 /60]
X 46
= 7,427
Schedule Air Sensible Area
Ceiling
Height
ACH
AT.
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
76,361
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-12-17713:52:57 ID:
Page 18 of 23
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Black Residence 1 12/17/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Black altered residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,800.0 ffz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 °F
Outdoor Dailv Ranne:
34 OF
Opaque Surfaces
Default 1978 to present
R-13 Wall
R-13 Wall
R-13 Wall
1 R-13 Wall I
Orientation
(►M
(N)
(E)
(St
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
_
3,800.0
0.0790
56.0
569.5
0.1020
23.0
872.8
0.1020
33.0
581.8
0.1020
26.0
520.9
0.1020
33.0
36.5
26.4
36.5
0.0
36.5
16.0
36.5
0.0
36.5
4.0
36.5
0.0
36.5
4.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
existing
existing
existing
existing
existing
existing
Fx
iting
isting
isting
Oripnt atinn
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0X
36.5+
30.6X
0.0
36.5
54.0
--36.5=
36.5
0.0
'36.5
27.0
36.5
0.0
36.5
26.4
36.5
0.0
36.5
16.0
36.5
0.0
36.5
4.0
36.5
0.0
36.5
4.0
36.5
0.011
36.5
4.0
36.5
0.0
36.5
4.0
36.5
Page Total
Btu/hr
16,811
1,336
6,
146
146
146
146
Internal Gain Batu/hr
Occupants 11.4 Occupants X 245 Btuh/occ.
Equipment 3,800 Floor Area X 0.50 w/sqft 6,`
Infiltration: 1.064 X 0.94 X 156.73 X 42 = C
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,2051
Latent Gain Btu/hr
Occupants 11.4 Occupants X 155 Btuh/occ. = 1,767
Infiltration: 4,771 X 0.94 X 156.73 X 0.00523 = 3,661
Air Sensible CFM ELA AW
•
LTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,767
I EnergyPro 6.7 by EneryySoft User Number. 6712 RunCode: 2015-12-17T13:52:57 ID: Pape 19 of 231
•
•
•
RESIDENTIAL. ROOM COOLING LOAD SUMMARY
Project Name Date
Black Residence 12/17/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Black altered residence I
Outdoor Dry Bulb Temperature
112 OF,
Floor Area
3;800.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb.Temperature
70 OF 1
Outdoor Dailv Ranae:
34 OF
e Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD1
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
0.0
36.5
4.0
36.5
0.0
19.7
21.6
19.7
0.0
19.7.+
48.0
19.7
0.0
19.7
21.6
• 19.7
0.0
36.5
27.3
36.5
0.0
.36.5
13.7
72.1
0.0
36.5
14.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fenestration
existing
altered
altered
altered
existing
existing
existing
existing
existing
OriPntatinn
(N)
(N)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
36.5
4.0
36.5
0.0
19.7
21.6
19.7
0.0
19.7.+
48.0
19.7
0.0
19.7
21.6
• 19.7
0.0
36.5
27.3
36.5
0.0
.36.5
13.7
72.1
0.0
36.5
14.0
72.1
0.0
36.5
48.0
72.1
0.0
36.5
31
Page Total
Btu/hr
tstufnr
146
995
988
1,009
3,460
1,9681
Internal Gain Btu/hr
Occupants 11.4 Occupants X 245 Btuh/occ.
Equipment 3,800 1 Floor Area X 0.50 w/sgft 6,
Infiltration: 1.064
Air Sensible
X 0.94
CFM
X 156.73
ELA
X 42 = 6,551
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
99,205
Latent Gain Btu/hr
Occupants 11.4 Occupants X F 155 Btuh/occ. = 1,767
Infiltration: 4.771 X 0.94 X 156.73 X 0.00523 = 3,661
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 1,7671
EnergyPro 6.7 by EnergySoft User Number.- 6712 RunCode: 2015-12-1IT13:52:57 ID: Pape 20 of 23
•
•
RESIDENTIAL ROOM.COOLING LOAD SUMMARY
Project Name Date
Black Residence 12/17/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Black altered residence
Outdoor Dry Bulb Temperature
112 °F
Floor Area ,
3,800.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Range:
34 OF
e Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
=
0.01
36.5
17.1
72.1
0.0
36.5
17.1
72.1
0.0
36.5
48.0
36.6
0.0
36.5
2.4
36.6
0.0
36.5
2.4
36.6
0.0
36.5
8.4
36.6
0.0
36.5
24.5
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
existing
existing
existing
existing
existing
existing
existing
existing
aftered
Orientation
(E)
(E)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.01
36.5
17.1
72.1
0.0
36.5
17.1
72.1
0.0
36.5
48.0
36.6
0.0
36.5
2.4
36.6
0.0
36.5
2.4
36.6
0.0
36.5
8.4
36.6
0.0
36.5
24.5
36:6
0.0
36.5
25.0
36.6
0.0
19.7
22.4
19.8
Page Total
01
Btu/hr
1,233
1,233
1,757
88
88
307
897
915
443
Internal Gain Btu/hr
Occupants 11.4 Occupants X 245 Btuh/occ. 2•
Equipment 3,800 Floor Area X 0.50 w/Sgft = 6;
Infiltration: 1.064 X 0.94 X 156.73 X 42 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,2051
Latent Gain Btu/hr
Occupants 11.4 Occupants X 155 Btuh/occ.. = 1,767
Infiltration: 4,771 X 0.94 X 156.73 X 0.00523 = 3,661
Air Sensible. CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1, 767
I EnergyPro 6.7 by EnergySoft User Number., 6712 ReinCode: 2015-12-17T13:52:57 ID: Page 21 of 23 1
•
•
.RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Black Residence 12/17/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Black altered residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,800.0 ft'
Outdoor Wet'Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Range:
34 OF
ue Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD1
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
0.0
19.7
40.0
19.8.=
0.0
19.7
22.5
19.8
0.0
36.5
54.0
36.6
0.0
• 36.5
30.6
36.6
0.01
36.5
30.6
72.1
0.0
19.7
54.0
34.0
0.0
36.5
30.6
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPnectratinn
altered
altered
existing
existing
existing
altered
Fx
iting
isting
isting
Orientation
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
0.0
19.7
40.0
19.8.=
0.0
19.7
22.5
19.8
0.0
36.5
54.0
36.6
0.0
• 36.5
30.6
36.6
0.01
36.5
30.6
72.1
0.0
19.7
54.0
34.0
0.0
36.5
30.6
72.1
0.0
36.5
20.7
72.1
0.0
36.5
108,01
72.1
Page Total
Btu/hr
•Btu/hr
790
445
1,977
1,120
2,206
1,834
2,206
1,492
7,785
19,85
Internal Gain
Btu/hr
Occupants
11.4 Occupants X
245 Btuh/occ:
2,;
Equipment
3,800 Floor Area X
0.50 'w/sgft
=
Infiltration: 1.064 X 0.94 X 156.73 X 42 = 6,551
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,2051
Latent Gain Btu/hr
Occupants 11.4 Occupants X 155gtuh/occ. = 1,767
Infiltration: 4.771 X 0.94 X 156.73 X 0.00523 = 3,661
Air Sensible CFM ELA AW
1
I EnergyPro 6.7 by EnemySoft User Number 6712 RunCode: 2015-12-17T13:52:57 ID: PaW 22 of 23 1
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Black Residence
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Black altered residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,800.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
existing
(VV) 0.0 X 36:5 +
20.7 X
72.1
= 1,492
existing
(tM 0.0 X 36.5 +
4.0 X
72.1
= 288
altered
(W) 0.0 X 19.7 +
54.0 X
34.0
= 1,834
existing
(lM 0.0 X 36.5 +
54.0 X
72.1
= 3,893
existing
(V1) 0.0 X 36.5 +
54.0 X
72.1
= 3,893
existing
(VV) 0.0 X 36.5 +
58.5 X
72.1
= 4,217
X +
X
=
X +
X
=
X +
X
=
Page Total
Internal Gain
Btu/hr
Occupants
11.4 Occupants X 245
Btuh/occ.
=
2,793
Equipment
3,800 Floor Area X 0:50
w/sgft
=
6,485
Infiltration: 1.064
X 0.94 X 156.73 X 42 =
6,551
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
99,205
Latent Gain
Btu/h.r
Occupants
11.4 Occupants X 155
Btuh/occ.
=
1,767
Infiltration: 4,771
X 0.94 X 156.73 X 0.00523 =
•3,661
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,767
Ene Pro 6.7 by EnergySoft
User Number: 6712 RunCode: 2015-12-17713:52:57 ID:
Page 23 of 23