Loading...
BRES2015-045078-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRES2015-0450 Property Address: 80435 WEISKOPF APN: 762090011 Application Description: BLACK / REMODEL BATH Property Zoning: Application Valuation: $200,000.00 Applicant: BLACK FAMILY TRUST 80435 WEISKOPF LA QUINTA, CA 92253 mud 4 44wfw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 7774011 INSPECTIONS (760) 777-7153 I IIIIII II"I IIII IIII Owner: 11 KENNETH BLACK & KA TRUST 57630 BALLYBUNION A. KITHCEN, WINDOWS, LIGHTING LA QUINTA, CA 92253 ® A � 0 DEC 17 201 Contractor: OWNER BUILDER CITY 0.= LA QUINTA LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the bas' ` for the alleged exemption. Any violation of Section 7031.5 by any applicant for a pe i ubjects the applicant to a civil penalty of not more than five hundred dollars r"OZ.M4 )•: I, as owner of the property, or my employees with wages as their sole ensation,will do the work, and the structure is not intended or offered for sale. .7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements areof intended or offered for sale. If, however, the building or improvement is sold wit n one year of completion, the owner -builder will have the burden of proving that heAr she did not build or improve for the purpose of sale.). as owner of the property, am exclusively contracting with licensed contractors construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State icense Law does not apply to an owner of property who builds or improves they o , and who contracts for the projects with a contractor(s) licensed pursuant to th ontractors' State License Law.). I am exempt under Sec. , B.&P.C.j6r this reason Date: f�i�TRUCTIONDING AGENCY I hereby affirm under al 7of perjuryt at there is a construction lending agency for the performance of h� ork for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Add Lic. No.: Date: 12/17/2015 WORKER'S COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Polity Number: 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. A�t issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state law elating to building construction, and hereby authorize representatives of this city t enter upon the above-mentio ed Pr"erty for inspection purposes. Date: Signature (Applicant e x IDE ' Y ACONT QTY AMO NT. A U ,:kPAID �A E °,BSl45:5$3473"FEE 101-000020306. ". 0 $8:00~' $8.00. 12J17j15 Sk 101111b f�.�AF�D BY h 4.. ET OD �, K RIPT # CHEC _ Ya KENNETH BLACK & KATRUST CHECK: R11606 1119 SGU Total Paid for'BUILDING STANDARDS ADMINISTRATION BSA: $8.00 $8.60. `DESCRIPTION �ACGOUNT QTY ,AMOUNT PAID PAID�DATE RESIDENTIAL,_ EA ADDITION 1,0005F 101-0000-42403 0 _ $36.99 '$36.99 12/17/15 � ID'BY , ' yMET�H�OD�_ RE T W' CK # CLTU BY KENNETH BLACK & KA TRUST CHECK R11606 -1119 SGU sA SCRIPTION A COUNT :QTY AMOUNT, PAID P�AIDDATE RESIDENTIAL, EA ADDITION'1,000SF,'PC 101-0000-42600 0 $15.24 $15.24 12/17/15 �� �� R C INT#a ...E C ECK # ,. CLTD Blf KENNETH BLACK & KA TRUST, CI4ECK R11606 1119 .:SGU �� j DES RIPTION �.. AUN QT;Y AMOUNTq p �p�Dx'p 'RESIDENTIAL, FIRST 1,000SF 101:0000=42403. � 0 $145.03 $145.03 .' 11/17%15 ! $ {� -. L."5 •'X'T >T 4. 413 '>+-5 &�. �4 'PAID BY w,k. � . �4 7}aSd�3'J�4r �. r b , .. ` METHOD. `, $ ' � > L RE N. Nffl Kms#. CLTDBY :KENNETH BLACK & KA TRUST ` ' CHECK R11606 1119 SGU ham., 3DESCRI TION s /1000UQTY AMOUNT PAID %PAID E RESIDENTIAL, FIRST 1,000SF, PC 101-0000=42600 0 $47.86 $41.86 '12/17/15" R�101 onMETHOD RECEIPT# CiiECK.# x CL�TDrBY 'KENNETH BLACK & KA TRUST CHECK . R11606 1119 SGU Total Paid•for;ELECTRICAL- NEW CONSTRUCTION: $245.12 $245.1-2., �5' 2 DESCRIP 1ON 'pry = ,.ACT"AMOUpNT �a Q.. ax �'"D—,x PAID> M xP�AID>;D�ATE� FIXTURE/TRAP 101-0000-42401 0 $169:26 $169.26"12/17/15' X36.�e' � Ytt v .•r +' �qyx.. •4XY `Y yp`�4 � z'Y'... � �§ � { �,< � PAID776Y �. •r^'n ion HOD �yr$� RECEIPT # "` .�` C CK # . CLTD�6 KENNETH BLACK & KA TRUST CHECK R11606 _ 1119' SGU 5xDESCRIPTIONr 'SMr ,ACCON .QTY , .4MONT . A>pA E FIXTURE/TRAP PC 101-0000-42600 0 '. $169:26 .$169.26 12/17/15 �.;s �y,sy�P`AIDBY� §y:.h}N`.C._yx%��"�;.�i�„,,..::vk."A,+4.� M HOD ... ..- REC PT # .. vaf.S:It.2 .... CHECK It x CLTD`BY KENNETH BLACK & KA TRUST CHECK R11606 1119 -SGU Total Paid for PLUMBING FEES: - ; $338.52 $338.52. rDESCRIP�TION, ACCOUNT AMOUNT PAID b< PADDATE SMI - RESIDENTIAL 101-0000-20308 0 $26:00 , $26.00 12/17/15 PLAID B,Y°METHOD .4 . N a b s� RCE PTz# W e s CHECK # - � r CLkTD'BY � , KENNETH BLACK .& KA TRUST CHECK R11606 1119 SGU Total Paid for STRONG, MOTION INSTRUMENTATION SMI: $26.00 $26.00 DESCRIPTION y A` OU T �.-. TY ; �:; AMO �T rlop �M. PAID PA D DATE DOOR/WINDOW, REPLACE FIRST 7. 101-0000=42400, 6' "$60.91 $60.91 12/17/15 ,PAID,BY .. .:. � a Al ; ME H T # � y CHECK# ;CCTD; le KENNETH BLACK &•KA TRUST CHECK 1111606 1119 SGU a D�E.,SGRIPIO dCU 4 AMUN PAIDi vu PAI'DO DOOyR/WINDOW, REPLACE, EA ADDITIONS 101-0000-42400 0. $10:15 $10:15; 12/17/15 :� "r�*���Atii��f* �� METHODSRECEIPT# a��.s2 ��CHECK# 5.`1�.k'' ✓...�''h 4x:`.*% CLTp Blf ti „ ,, ,...k;+.i.. 3nFtw,r'7: N.<e+.`a KENNETH BLACK & KA TRUST CHECK " 'R11606 1119 SGU .k. iC ':S f )S I✓NY 'iu M'f'.n" <Yy,fya�� �Y {�. 4. , ai'h``.., xII ,CSS ACCQUNT�..19T, Zr +Ki( LL PAI' '�a',4ob`?ss y.. 'i .:•av DAT ,rh :� t ,DESCRIPTION JY .:. LAID DOOR/WINDOW, REPLACE, EA ADDITION 5 101-0000-42600 0. $11.60 $11.60 12/17/15 PC � EC4D X4w w kChL'v1T, Dk ' BYEC .'>F.':. e KENNETH BLACK & KA TRUST CHECK R11606 1119 SGU DESCRIP.TIONn;�� ACCOUNT BAID x PAID�DATE .` DOOR/WINDOW, REPLACE, FIRST 7 PC' 101-0000-42600 0 $110.22 $110.22 .12/17/15 PAID BY�.� MHO�usx m "`d `3*.cA�:�-. RECEIj# CHECK#CLTBY� x�`iYf`L���n'-'.;.'7z'- s. ,: z 3✓ ,. _ KENNETH BLACK & KA TRUST CHECK R11606 1119 SGU Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION:. ' $192.88 $192.88 • Description: BLACK / REMODEL BATHROOM, KITHCEN, WINDOWS, LIGHTING Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 12/14/2015 SGU Approved: 12/17/2015 JFU Parcel No: 762090011 Site Address: 80435 WEISKOPF LA QUINTA,CA 92253 Subdivision: TR 28444 Block: Lot: 5 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $200,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 ANGELICA ZARCO Details: INTERIOR REMODEL. REPLACE (8) WINDOWS/DOORS. REPLACE RECEPTACLES THROUGHOUT HOUSE AND INSTALL NEW RECEPTACLES AT KITCHEN TO MATCH NEW CABINET LAYOUT. REPLACE EXISTING LIGHTING THROUGHOUT HOUSE WITH HIGH EFFICACY LED FIXTURES. REMODEL (4) SHOWERS AND REPLACE (10) SINKS. 2013 BUILDING CODES. ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE . STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE ANGELICA ZARCO 12/17/2015 12/17/2015 RECEIVED TITLE 24 SUBMITTAL PLAN CHECK SUBMITTAL STEPHANIE GUMPERT 12/14/2015 12/14/2015 RECEIVED RESUBMITTAL JAKE FUSON 12/17/2015 12/17/2015 REVISED TITLE 24 REPORT SUBMITTED VIA EMAIL. NOTIFIED KEN BLACK (949-422-1877) THAT PLANS WOULD BE TELEPHONE CALL JAKE FUSON 12/17/2015 12/17/2015 READY FOR APPROVAL PENDING THE SUBMITTAL OF A REVISED TITLE 24 REPORT.' LEFT MESSAGE FOR JON SCOTT (ENERGY CONSULTANT) AT TELEPHONE CALL JAKE FUSON 12/17/2015 12/17/2015 760-200-4780 NOTIFYING HIM THAT THE ENERGY REPORT HE PREPARED FOR THIS PROJECT DID NOT MATCH THE SCOPE OF WORK AND WOULD NEED TO BE REVISED. Printed: Thursday, December 17, 2015 4:03:36 PM 1 of 4 row— ......... CONDITION DATE DATE DATE PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY CONTACT $8.00 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU STATUS REMARKS NOTES TYPE 101-0006-42403 ADDED REQUIRED SATISFIED 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA _ SGU ADDITION 1,000SF CONTRACTOR REQUIRED PRIOR TO PERMIT READY TO ISSUE JAKE FUSON 12/17/2015 12/17/2015 101-0000-42600 COMPLETE $15.24 ISSUANCE. CHECKLIST R11606 1119 CHECK KENNETH BLACK & KA SGU ADDITION 1,000SF, PC TRUST OWNER BUILDER AS CONTRACTOR 101-0000-42403 0 $145.03 CONTACTS 12/17/15 R11606 NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT BLACK FAMILY TRUST 80435 WEISKOPF LA QUINTA CA 92253 CONTRACTOR OWNER BUILDER TRUST RESIDENTIAL, FIRST 101-0000-42600 OWNER KENNETH BLACK .& KA TRUST 57630 BALLYBUNION LA QUINTA CA 92253 R11606 FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $8.00 $8.00 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU TRUST Total Paid for BUILDING STANDARDS ADMINISTRATION $8.00 $8.00 BSA: RESIDENTIAL, EA 101-0006-42403 0 $36.99 $36.99 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA _ SGU ADDITION 1,000SF TRUST RESIDENTIAL, EA 101-0000-42600 0 $15.24 $15.24 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU ADDITION 1,000SF, PC TRUST RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU 1,000SF TRUST RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU 1,000SF, PC TRUST Total Paid for ELECTRICAL- NEW CONSTRUCTION: $245.12 $245.12 FIXTURE/TRAP 101-0000-42401 0 $169.26 $169.26 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU TRUST Printed: Thursday, December 17, 2015 4:03:36 PM 2 of 4 Arfirw ........ Printed: Thursday, December 17, 2015 4:03:36 PM 3 of 4 ICNWW_........ CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY FIXTURE/TRAP PC 101-0000-42600 0 $169.26 $169.26 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU TRUST Total Paid for PLUMBING FEES: $338.52 $338.52 SMI - RESIDENTIALT 0 I101-0000-20308 $26.00 $26.00 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU TRUST Total Paid for STRONG MOTION INSTRUMENTATION SMI: $26.00 $26.00 DOOR/WINDOW, 101-0000-42400 0 $60.91 $60.91 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU REPLACE FIRST 7 TRUST DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42400 0 $10.15 $10.15 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU TRUST 5 DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42600 0 $11.60 $11.60 12/17/15 R11606 1119 CHECK KENNETH BLACK & KA SGU TRUST 5 PC DOOR/WINDOW, 101-0000-42600 0 $110.22 $110.22 12/17/15 R11606 1119 CHECK K KENNET & KA SGU REPLACE, FIRST 7 PC TRUST TRUST Total Paid for WINDOW/SLIDING GLASS $192.88 $192.88 DOOR/FENESTRATION: TOTALS: $810.52 $810.52 Printed: Thursday, December 17, 2015 4:03:36 PM 3 of 4 ICNWW_........ 2ND BLDG NS (1 I JAKE FUSON 112/17/2015 112/17/2015 112/17/2015 I APPROVED I I WK) BOND INFORMATION Printed: Thursday, December 17, 2015 4:03:36 PM 4 of 4 Bin #/ I City of La Quin to Building 8t Safety Division' 78-495 Calle Tampico j O La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet / rr it 1. roject Address:-� l' , Owner's Name• P. Number: . gam' Address: Zn,,:�;> S Legal Description: City, ST, Zip: LA, �' < Contractor:. r• o � T h ele one: z- P Address: Project Description: City, ST, Zip: Telephone: e• elePhn. .. State Lic. # : City Lic. #: LP s.1 Arch., ];ngr., Designer: Address: r- F-- L �i City, ST, Zip: Telephone: c Occupancy: •Co truction TYPe State Lic. #. Project (circlele ne)• New A dd'n Alter a a' Demo Name of Contact Person: L&SE4 Sq. Ft.:,� # Stories: # Units: K,-p:ho:ne # of Contact Person: 24h - Estimated Value of Project: 2 , APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Rcq'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. II.O.A. Approval flans resubmitted Grading IN ROUSE:- ''". Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue Schoch Fees, Total Permit Fees _q$ 1 CITY OF LA QUINTA SUB-CONTAC , IS JOB ADDRESS `f�5 �PERMIT NUMBER _OWNER ( L �„ SWLDER This form shall be posted on the ioh with tie Building Inspection Card at all times in a conspicuous place, Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by aoolicant. "On File" is not an accentable resoonse. Trade / Classification Contractor State Contractor's License Workers Comp onsation Insurance-777r City,Business License Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C-12) CONCRETE;(C:;81.: r , FRAMING (C-5), ST.RUCT. STEEL (C-51), MASONRY (C-29) LATH, PIASTER (C-351,,. DRYWALL (C-9) • HVAC (Cr20) .. i c ROOFING (C-39) SHEET METAL IC -43)'' FLOORING (C-15) INSULATION (C=2) SEWAGE'DISP: (G42) PAINTING(C=3.3), CERAMIC TILE,(C-6.4) CABINETS (C-6). ; FENCING (CJ21), LANDSCAPING (C-271' POOL (C-53)' T-11dY 4 4 Qaha� P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760) 777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a buildin ha ub�itted y me listing yourself as the builder of the property improvements specified at We are providing you with anOwner- udder Acknowl ent d Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. Read and initial each statement below to signify you understand or verify this information. 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my roperty. - 2. I understand building permits are not required to be signed by property owners unless they are responsible for the conssf, o on and are not hiring a licensed Contractor to assume this responsibility. 3. I understand as an "Owner -Builder" I am the responsible of record on the 't. I understand that I may protect sP PAY 1�� Y 4. I �derstand Contractors are.required by law to be licensed and bonded in California and to list their license numbers on perm t,�and contracts. 5. I unde stand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my co traction is at least five hundred dollars ($500), including labor and materials,•I may considered an "employer" under to and federal law. 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment co/7nderstand n for each "employee." I also understand my failure to abide by these laws may subject me to serious -financial ris under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 8. I understand as an. Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial orders. nal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the w7,9understand Kip or materials. I may obtain -more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.csib.ca.gov for more information about licensed contractors. 10.1 am aware of and consent o an Owner -Builder building permit applied for in my name, and understand that I am the party le a fy jally �s onsi le � proposed co on activity at the following address: t^ f 11. I aF-le-that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicabl aws and requirements that govern Owner -Builders as well as employers. 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors, may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those. Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permf�ote: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the ageW is reguired to be presented when the permit is issued to verify the property owner's signature. Signature of propertyowner Date: Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the -following -persons) -to -act as-my-agent(s)-to-apply-for-sign,-and-file-the-documents-tiecessary-to-obtain-an-Owner=Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license; form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: %A 4 � ` See 1-S lc blf)e 4 Sins 4,,'s A4e &t7A L4pgrqcleW 4()N_A ddllpl, 6liq ld� e- CS N o -TE) ,X15� 4q 51pp? A -L (,i o 4 1>,,Y a W 4r) mvAe Icy box kck)ls, MV.ST LIS 10 1,A 6Al2 A Ren�ode,l L e, q ewd: tj SlMk5 CAB .......... %% Om ( 'a " CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE[7 �PIS BY m Al wap L RE CEIVE®...___, -DEC 14 2015 CITY OF LA n! qQ" 117A COMMUNITY LEVL-_.l;4li',.iENT y • �i `o _• d 1' s 7 ti. ; .t pit; � • � -lea- C Iii•' " 4 ! 4v Dy • Cc��rFr t � w CITY ®F LAQUINTA BUILDING & SAFETY DEPT, --- RECEIED APPROVED,, DEC 142015 FOR CONSTRUCTION CITY OF LA r11.91alT� DATE- _BY COMMUNITY' ty Li+Dii11.� d'e �0 Allo ' $ SIOZ 1 030 a Z a3AI333H 0 o 1 el�l Isv • 7Rd ca .•j t I CIP OF LA QUINTA 7, BUILDING & SAFETY DEPT. APPROVED F R CONSTRUCTION . DATE BY JF izto ? I is tI zo it 36 AliNnWWOO .10 V110 A113 5;011330 1 .4 CITY OF LA QUINT BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION DATE BY RE I m ri 00 II 0:! CL! .4 CITY OF LA QUINT BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION DATE BY RE I m I BUILDING ENERGY ANALYSIS REPORT PROJECT: Black Residence 80-435 Weiskopf La Quinta, CA 92253 Project Designer: Chad McAfee 42-240 Green way STE G Palm Desert, CA9260 (760) 578-6248 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 OFFi.c c " F F LAG &SAFETY DEPT.PROVED IF ONSTRUCTION Job Number: DATEIZ / Za/,Gj13Y_ Date: 12/17/2015. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standard's. This program developed by EnergySoft, LLC—www.energysoft.com. EnergyPro 6.7 Ty EnergySoft User Number. 6712 ID: PiI J ,,u lr 'IV i �a� ..�.. •ice _ '� V its ourrc t zvioll) flij U i • a - TABLE OF CONTENTS. Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3. Form RMS -1 Residential Measures Summary 11 Form MF -1 R Mandatory Measures Summary ' 12 HVAC System Heating and Cooling. Loads Summary 16 Room Load Summary 17. Room Heating Peak Loads 18 Room Cooling Peak Loads. 19 EnergyPro 6.7 by Energysoft Job Number: ID: User Number. 6712 CERTIIQTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE (SHOD Project Name: Black Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xmi CO -PRF -01 Pagel of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Black Residence 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ftz-yr) 03 Project Location 80-435 Weiskopf Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 3800 15 Number of Zones 1 16 Slab Area (ft) 3800 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (W) 0 21 Glazing Percentage (%) 31.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building Jincorporates one or more Special Features shown below. Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance 'Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-12-17 13:52:31 . ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftz-yr) Standard Design Proposed_Design Compliance Margin Percent Improvement Space Heating 4.53 5.28 -0.75 -16.6% Space Cooling 284.11 282.29 1.82 0.6% IAQ Ventilation 0.00 0.00 0.00 '0.0% Water Heating' 6.61 6.50 0.11 1.7% Photovoltaic Offset — 0.00 0.00 -- Compliance Energy Total 295.25 294.07 1.18 0.4% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance 'Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-12-17 13:52:31 . CERTINTE OF COMPLIANCE - RESIDENTIAL 'PERFORMANCE COMPLIANCE *OD Project Name: Black Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY CIRPRF-01 Page 2 of 8 The following is a summary of the features that must be field -verified, by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • — None -- Cooling System Verifications: • — None -- HVAC Distribution System Verifications: • — None -- Domestic Hot Water System Verifications: • — None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an r on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)" 334.38 333.20 1.18 0.4% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Black Residence 3800 1 3 1 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone•Name Zone Type HVAC System Name Zone Floor Area (ft') Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 3800 9 DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 13:52:31 =ORMANCE COMPLIANCE #06 Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xm1 CO -PRF -01 Page 3 of 8 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 03 04 05 06 07 08 09 10 Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (tt2) Tilt '(deg) Status Verified Existing Condition R-13 Wall 0 Right 862 292.5 90 Existing No R-13 Wall 90 Front 1010 137.2 90 Existing No R-13 Wall 180 Left 862 280.2 90 Existing No R-13 Wall 270 Back 1010 489.1 90 Existing No Defaul: 1978 to present 3800Existing No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 03 04 05 06 Type Roof Rise Roof Reflectance Roof Emittance Ventilated 3 0.1 0.85 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 SIDENTIAL PERFORMANCE COMPLIANCE SOD /sis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xml COPRF-01 Page 4 of 8 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Multiplie Width(ft) Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition existing N Wail ex (Right -0) - - 1 30.6 0.71 0.60 Insect Screen (default) Existing No existing 2 N Wall ex (Right -0) - - 1 54.0 0.71 0.60 Insect Screen (default) Existing No existing 3 N Wall ex (Right -0) - - 1 27.0 0.71 0.60 Insect Screen (default) Existing No existing 4 N Wall ex (Right -0) - - 1 26.4 0.71 0.60 Insect Screen (default) Existing No existing 5 N Wall ex (Right -0) - - 1 16.0 0.71 0.60 Insect Screen (default) Existing No existing 6 N Wall ex (Right -0) - - 1 4.0 0.71 0.60. Insect Screen (default) Existing No existing 7 N Wall ex (Right -0) - - 1 4.0 0.71 0.60 Insect Screen (default) Existing No existing 8 N Wall ex (Right -0) - - 1 4.0 0.71 0.60 Insect Screen (default) Existing No existing 9 N Wall ex (Right -0) - - 1 4.0 0.71 0.60 Insect Screen (default) Existing No existing'10 N Wall ex (Right -0) - - 1 4.0 0.71 0.60 Insect Screen (default) Existing No altered N Wall ex (Right -0) - - 1 21.6 0.54 0.24 Insect Screen (default) Altered N/A altered 2 N Wall ex (Right -0) - - 1 48.0 0.54 0.24 Insect Screen (default) Altered N/A altered 3 N Wall ex (Right -0) - - 1 21.6 0.54 0.24 Insect Screen (default) Altered N/A existing 11 N Wall ex (Right -0) - - 1 27.3 0.71 0.60 Insect Screen (default) Existing No existing 12 E Wall ex (Front -90) - - 1 13.7 "0.71 0.60 Insect Screen (default) Existing No existing 13 E Wall ex (Front -90) - - 1 14.0 0.71 0.60- Insect Screen (default) Existing No existing 14 E Wall ex (Front -90) - - 1 48.0 0.71 0.60 Insect Screen (default) Existing No existing 15 E Wall ex (Front -90) - - 1 27.3 0.71 0.60 Insect Screen (default) Existing No existing'16 E Wall ex (Front -90) - - 1 17.1 0.71 0.60 Insect Screen (default) Existing No existing 17 E Wall ex (Front -90) - - 1 17.1 0.71 0.60 Insect Screen (default) Existing No existing 18 S Wall ex (Left -180) - - 1 48.0 0.71 0.60 Insect Screen (default) Existing No existing 19 S Wall ex (Left -180) - - 1 2.4 0.71 0.60 Insect Screen (default) Existing No existing 20 S Wall ex (Left -180) - --- 1 2.4 0.71 0.60 Insect Screen (default) Existing No existing 21 S Wall ex (Left -180) - - 1 8.4 0.71 0.60 Insect Screen (default) Existing No existing 22 S Wail ex (Left -180) - - 1 24.5 0.71 0.60' Insect Screen (default) Existing No existing 23 S Wall ex (Left -180) - - 1 25.0 0.71 0.60 Insect Screen (default) Existing No altered 4 S Wall ex (Left -180) - - 1 22.4 0.54 0.24 Insect Screen (default) Altered N/A altered'5 S Wall ex (Left -180) - - 1 40.0 0.54 0.24 Insect Screen (default) Altered N/A altered 6 S Wall ex (Left -180) - - 1 22.5 0.54 0.24 Insect Screen (default) Altered N/A Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-12-17 13:52:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IVOD Project Name: Black Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xmi CO -PRF -01 Page 5 of 8 existing 24 S Wall ex (Left -180) - - 1 54.0 0.71 0.60 Insect Screen (default) Existing No existing 25 S Wall ex (Left -180) - - 1 30.6 0.71 0.60 Insect Screen (default) Existing No existing 26 W Wall ex (Back -270) - - 1 30.6 0.71 0.60 Insect Screen (default) Existing No altered 7 W Wall ex (Back -270) - - 1 54.0 0.54 0.24 Insect Screen (default) Altered N/A existing 27 W Wall ex (Back -270) - - 1 30.6 1 0.71 0.60 Insect Screen (default) Existing No existing 28 W Wall ex (Back -270) - -- 1 20.7 0.71 0.60 Insect Screen (default) Existing No existing 29 W Wall ex (Back -270) - -- 1 108.0 0.71 0.60 Insect Screen (default) Existing No existing 30 W Wall ex (Back -270) - - 1 20.7 0.71 0.60 Insect Screen (default) Existing No existing 31 W Wall ex (Back -270) - - 1 4.0 0.71 0.60 Insect Screen (default) Existing No altered 8 W Wall ex (Back -270) - - 1 " 54.0 0.54 0.24 Insect Screen (default) Altered N/A existing 32 W Wall ex (Back -270) - - 1 54.0 0.71 0.60 Insect Screen (default) Existing No existing 33 W Wall ex (Back -270) - - 1 54.0 0.71 0.60 Insect Screen (default) Existing No existing•34 W Wall ex (Back -270) - - 1 58.5 0.71 0.60 Insect Screen (default) Existing No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 . Name Zone Total Cavity Winter "Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 186 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below . Cavity %Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking SLAB FLOORS 01 02 03 04 06 06 07 08 09 . Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 3800 186 None 0.8 No Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 13:52:31 CERTIQTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE N*OD Project Name: Black Residence .Calculation Description: Title 24 Analysis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xrhl BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — CRF -01 Page 6of8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes 1 Cooling Yes Air Distribution HVAC Fan 3800 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC -'HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-12-17 13:52:31 CERTATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE AOD Project Name: Black Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xml APRF-01 Page 7 of 8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Verified Duct Location Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12No Duct Leakage No N/A Location system Status' Condition - Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 .04 05 06 07 08 09 10 Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Insulation Supply Duct Return Duct Verified Existing HERS .Name Type Duct Leakage R -value Location Location Bypass Duct Status' Condition - Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans VVH Fan 1 61 0.52459 1 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-12-17 13:52:31 CERTATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE AOD Project Name: Black Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 13:51, Thu, Dec 17, 2015 Input File Name: Black Res -Chad McAfee-15.xml T CO -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon Scott Company: Signature Date: Scott Design and Title 24, Inc, 12/17/2015. Address:. CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive City/State!-81•m Desert, CA 92211 I' Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, . worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Chad McAfee Company: Date Signed: Chad McAfee Address: License: 42-240 Green way STE G City/State/Zip: Phone: Palm Desert, CA 9260 (760) 578-6248 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-12-17 13:52:31 • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Black Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 12/17/2015 Project Address 80-435 Weiskopf La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,800 Addition 0 # of Units 1 INSULATION Construction Type Area Cavi (ft) Special Features Status Roof Wood Framed Attic R11 3,800 Existing Wall Wood Framed R 13 2,545 Existing Slab Unheated Slab -on -Grade no insulation 3,800 Perim = 186' Existing Demising Wood Framed R 13 511 New FENESTRATION I Total Area: 1,199 Glazing Percentage: '31.6 % New/Altered Average U -Factor: 0.54 Orientation Area(ft). U -Fac SHGC Overhang Sidefins, Exterior Shades Status Right (N) 201.3 0.710 0.60 none none Bug Screen Existing Right (N) 91.2 0.540 0.24 none none Bug Screen Altered Front (E) 137.2 0.710 0.60 none none Bug Screen Existing Left (S) 195.3 0.710 0.60 none none Bug Screen Existing Left (S) 84.9 0.540 0.24 none none Bug Screen Altered Rear (W) 381:1 0.710 0.60 none none Bug Screen Existing Rear (IM 108.0 0.540 0.24 none none Bug Screen Altered HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6.7 by EnemySoft User Number.' 6712 Runcode: 2015-12-17713:52:57 ID: Pae 11 of 23 • • 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §I 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of. § 10-111 a . § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §I 10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110 8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(6): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-] 9 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. §150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption late, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater. than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets therequirements of § 110.8( . 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)]A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § I50.0(e)] B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00)] A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)]B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recireulation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A [§150.06)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. • • 2013 Low -Rise Residential Mandatory Measures Summary §150.0(j)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space. shall have a Class I §150.06)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class l or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or 1V vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §110.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct-closure'system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %< inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be corn ressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: piessure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)]A: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. • • 2013 Low -Rise Residential Mandatory Measures Summary 110.4(b)l : Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § I I0.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specifiedpump* sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)]A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)l B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)IC: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § I50.0(k)1 D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)l F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § I50.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if. it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §I50.0(k)2. § 150.0(k)3•A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook area's, are considered kitchen lighting if they are not.se arately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages; laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and §150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch thatdisables the motion sensor, or controlled by. a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: • • 0 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, 130.4, §140.7 and §141.0. §I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in 110.9, 130.0, §130.2, §130.4, §140.7 and 141.0. § 150.0(k)9D: Outdoor lighting.for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with theapplicable requirements in 110.9, 130.0, 130.2, 130.4, §140.7 and 141.0. ' § I50.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 13 0.0 c . § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, §130.0, §130.1, 130.4, 140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I 50.0(k) I 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § I 50.0(k) I 2B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l : tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 through 110.10 e . §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ' ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 ercent'of the total roof area of the buildin � excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §I 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solarelectric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder -location or main circuit location, and permanently marked as "For Future Solar Electric". • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Black Residence 12/17/2015 System Name Floor Area HVAC 3,800 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 Total Room Loads -Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING CFM Sensible 7,106 99,205 0 8,412 0 570 24,336 0 8,412 1 140,365 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 89,000 5,428 1,401 76,361 Total Output Btuh 267,000 Output Btuh/s ft 70.3 5,425 Cooling System 0 Output per System 35,500 3,966 570 27,168 Total Output Btuh 106,500 9,393 0 Total Output Tons 8.9 5,425 Total Output Btuh/s ft 28.0 Total Output s ft/Ton 428.2 114,379 Air System CFM per System 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 4,200 Existing HVAC 67,045 30,239 267,000 Airflow cfm15 ft 1.11 Airflow cfm/Ton 473.2 Outside Air % 13.6% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 67,045 30,239 267,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 65 OF 65 OF 124 OF O �1'14. Outside Air 570 cfm Supply Fan Heating Coil 123 OF 4,200 cfm �w ROOM 71 of Return Fan 71 OF 72 OF _[;�D 4,200 cfm COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 77/67°F 77/67°F 55/58°F Outside Zr- 570 cfm Supply Fan Cooling Coil 57 / 59 OF 4,200 cfm 72.6% ROOM• Return Fan 72/65°F 72/65°F 70/64°F O 4,200 cfm EnergyPro 6.7 by EnergySoft User Number 6712 Run Code: 2015-12-17713:52:57 ID: Page 16 of 23 • • ROOM LOAD SUMMARY Project Name Date Black Residence 12/17/2015 System Name Floor Area HVAC 3,800 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible Latent CFM Sensible residence Black altered residence 1 7,1061 99,2051 5,428 7,1061 99,2051 5,4281 1,4011 76,361 PAGE TOTAL 1 7,106 99,205 5,428 1,401 76,361 • TOTAL' 7,106 99,205, 5,428 1,401 76,361 Total includes ventilation load for zonal systems. EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T13:52:57 ID: Pae 17 of 23 • ROOM HEATING PEAK LOADS Project Name Date Black Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Black altered residence Time of Peak Jan 1 AM Floor Area 3,800.0•ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT *F Btu/hr Defaul: 1978 to present 3,800.0 X 0.0790 X 46 = 13,809 R-13 Wall 2,545.0 X 0.1020 X 46 = 11,941 Existing Window 914.9 X 0.7100 X 46 = 29,881 -LowE METAL .54.24 284.1 X 0.5400 X 46 = 7,057 Slab -On -Grade perim = 186.0 X 0.7300 X 46 = 6,246 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (`) denote conduction through an interior surface to another room Page Total 68,934 Infiltration:[ 1.00 X 1.064 X 3,800 X 9.00 X 0.266 /60] X 46 = 7,427 Schedule Air Sensible Area Ceiling Height ACH AT. Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 76,361 EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-12-17713:52:57 ID: Page 18 of 23 • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Black Residence 1 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Black altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,800.0 ffz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 °F Outdoor Dailv Ranne: 34 OF Opaque Surfaces Default 1978 to present R-13 Wall R-13 Wall R-13 Wall 1 R-13 Wall I Orientation (►M (N) (E) (St Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = _ 3,800.0 0.0790 56.0 569.5 0.1020 23.0 872.8 0.1020 33.0 581.8 0.1020 26.0 520.9 0.1020 33.0 36.5 26.4 36.5 0.0 36.5 16.0 36.5 0.0 36.5 4.0 36.5 0.0 36.5 4.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration existing existing existing existing existing existing Fx iting isting isting Oripnt atinn (N) (N) (N) (N) (N) (N) (N) (N) (N) Shaded Unshaded Area X X X X X X X X GLF + + + + + + + + Area X X X X X X X X GLF = = = = = = = = 0.0X 36.5+ 30.6X 0.0 36.5 54.0 --36.5= 36.5 0.0 '36.5 27.0 36.5 0.0 36.5 26.4 36.5 0.0 36.5 16.0 36.5 0.0 36.5 4.0 36.5 0.0 36.5 4.0 36.5 0.011 36.5 4.0 36.5 0.0 36.5 4.0 36.5 Page Total Btu/hr 16,811 1,336 6, 146 146 146 146 Internal Gain Batu/hr Occupants 11.4 Occupants X 245 Btuh/occ. Equipment 3,800 Floor Area X 0.50 w/sqft 6,` Infiltration: 1.064 X 0.94 X 156.73 X 42 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,2051 Latent Gain Btu/hr Occupants 11.4 Occupants X 155 Btuh/occ. = 1,767 Infiltration: 4,771 X 0.94 X 156.73 X 0.00523 = 3,661 Air Sensible CFM ELA AW • LTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,767 I EnergyPro 6.7 by EneryySoft User Number. 6712 RunCode: 2015-12-17T13:52:57 ID: Pape 19 of 231 • • • RESIDENTIAL. ROOM COOLING LOAD SUMMARY Project Name Date Black Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Black altered residence I Outdoor Dry Bulb Temperature 112 OF, Floor Area 3;800.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb.Temperature 70 OF 1 Outdoor Dailv Ranae: 34 OF e Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD1 = = = = = = = = = GLF = = = = = = = = 0.0 36.5 4.0 36.5 0.0 19.7 21.6 19.7 0.0 19.7.+ 48.0 19.7 0.0 19.7 21.6 • 19.7 0.0 36.5 27.3 36.5 0.0 .36.5 13.7 72.1 0.0 36.5 14.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration existing altered altered altered existing existing existing existing existing OriPntatinn (N) (N) (N) (N) (N) (E) (E) (E) (E) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 36.5 4.0 36.5 0.0 19.7 21.6 19.7 0.0 19.7.+ 48.0 19.7 0.0 19.7 21.6 • 19.7 0.0 36.5 27.3 36.5 0.0 .36.5 13.7 72.1 0.0 36.5 14.0 72.1 0.0 36.5 48.0 72.1 0.0 36.5 31 Page Total Btu/hr tstufnr 146 995 988 1,009 3,460 1,9681 Internal Gain Btu/hr Occupants 11.4 Occupants X 245 Btuh/occ. Equipment 3,800 1 Floor Area X 0.50 w/sgft 6, Infiltration: 1.064 Air Sensible X 0.94 CFM X 156.73 ELA X 42 = 6,551 AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,205 Latent Gain Btu/hr Occupants 11.4 Occupants X F 155 Btuh/occ. = 1,767 Infiltration: 4.771 X 0.94 X 156.73 X 0.00523 = 3,661 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 1,7671 EnergyPro 6.7 by EnergySoft User Number.- 6712 RunCode: 2015-12-1IT13:52:57 ID: Pape 20 of 23 • • RESIDENTIAL ROOM.COOLING LOAD SUMMARY Project Name Date Black Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Black altered residence Outdoor Dry Bulb Temperature 112 °F Floor Area , 3,800.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF e Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 0.01 36.5 17.1 72.1 0.0 36.5 17.1 72.1 0.0 36.5 48.0 36.6 0.0 36.5 2.4 36.6 0.0 36.5 2.4 36.6 0.0 36.5 8.4 36.6 0.0 36.5 24.5 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration existing existing existing existing existing existing existing existing aftered Orientation (E) (E) (S) (S) (S) (S) (S) (S) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.01 36.5 17.1 72.1 0.0 36.5 17.1 72.1 0.0 36.5 48.0 36.6 0.0 36.5 2.4 36.6 0.0 36.5 2.4 36.6 0.0 36.5 8.4 36.6 0.0 36.5 24.5 36:6 0.0 36.5 25.0 36.6 0.0 19.7 22.4 19.8 Page Total 01 Btu/hr 1,233 1,233 1,757 88 88 307 897 915 443 Internal Gain Btu/hr Occupants 11.4 Occupants X 245 Btuh/occ. 2• Equipment 3,800 Floor Area X 0.50 w/Sgft = 6; Infiltration: 1.064 X 0.94 X 156.73 X 42 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,2051 Latent Gain Btu/hr Occupants 11.4 Occupants X 155 Btuh/occ.. = 1,767 Infiltration: 4,771 X 0.94 X 156.73 X 0.00523 = 3,661 Air Sensible. CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1, 767 I EnergyPro 6.7 by EnergySoft User Number., 6712 ReinCode: 2015-12-17T13:52:57 ID: Page 21 of 23 1 • • .RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Black Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Black altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,800.0 ft' Outdoor Wet'Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF ue Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD1 = = = = = = = = = GLF = = = = = = = = 0.0 19.7 40.0 19.8.= 0.0 19.7 22.5 19.8 0.0 36.5 54.0 36.6 0.0 • 36.5 30.6 36.6 0.01 36.5 30.6 72.1 0.0 19.7 54.0 34.0 0.0 36.5 30.6 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnectratinn altered altered existing existing existing altered Fx iting isting isting Orientation Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 19.7 40.0 19.8.= 0.0 19.7 22.5 19.8 0.0 36.5 54.0 36.6 0.0 • 36.5 30.6 36.6 0.01 36.5 30.6 72.1 0.0 19.7 54.0 34.0 0.0 36.5 30.6 72.1 0.0 36.5 20.7 72.1 0.0 36.5 108,01 72.1 Page Total Btu/hr •Btu/hr 790 445 1,977 1,120 2,206 1,834 2,206 1,492 7,785 19,85 Internal Gain Btu/hr Occupants 11.4 Occupants X 245 Btuh/occ: 2,; Equipment 3,800 Floor Area X 0.50 'w/sgft = Infiltration: 1.064 X 0.94 X 156.73 X 42 = 6,551 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,2051 Latent Gain Btu/hr Occupants 11.4 Occupants X 155gtuh/occ. = 1,767 Infiltration: 4.771 X 0.94 X 156.73 X 0.00523 = 3,661 Air Sensible CFM ELA AW 1 I EnergyPro 6.7 by EnemySoft User Number 6712 RunCode: 2015-12-17T13:52:57 ID: PaW 22 of 23 1 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Black Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Black altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,800.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr existing (VV) 0.0 X 36:5 + 20.7 X 72.1 = 1,492 existing (tM 0.0 X 36.5 + 4.0 X 72.1 = 288 altered (W) 0.0 X 19.7 + 54.0 X 34.0 = 1,834 existing (lM 0.0 X 36.5 + 54.0 X 72.1 = 3,893 existing (V1) 0.0 X 36.5 + 54.0 X 72.1 = 3,893 existing (VV) 0.0 X 36.5 + 58.5 X 72.1 = 4,217 X + X = X + X = X + X = Page Total Internal Gain Btu/hr Occupants 11.4 Occupants X 245 Btuh/occ. = 2,793 Equipment 3,800 Floor Area X 0:50 w/sgft = 6,485 Infiltration: 1.064 X 0.94 X 156.73 X 42 = 6,551 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,205 Latent Gain Btu/h.r Occupants 11.4 Occupants X 155 Btuh/occ. = 1,767 Infiltration: 4,771 X 0.94 X 156.73 X 0.00523 = •3,661 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,767 Ene Pro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17713:52:57 ID: Page 23 of 23