Loading...
BCOM2016-004978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 MPERMIT IG DB VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/2/2016 Application Number: BCOM2016-0049 Owner: Property Address: 78370 HIGHWAY 111 STE 140 CITY OF LA QUINTA POINT HAPPY REALTY APN: 604050068 DESIGN AND DEVELOPMENT DEPARTMENT 8665 WILSHIRE BLV STE 410 Application Description: MIRACLE EAR/ T.I. NEW WALLS, ELECTRICAL, SPRNKLER BEVERLY HILLS, CA 92253 Property Zoning: _ 3 of the Business and Professions Code) or that he or she is exempt therefrom and the( Application Valuation: $8,000.00 — L_ — Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, Contractor: TENANT IMPROVEMENT CO TENANT IMPROVEMENT CO 75-400 20TH AVENUE COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, 75-400 20TH AVENUE SKY VALLEY, CA 92241 apply to an owner of property who builds or improves thereon, and who does the work SKY VALLEY, CA 92241 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 538824 011Date:--//'Z /L �-`Contractor: (760)408-5473 LIC. No.: 538824 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: • I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: EXEMPT Policy Number: I hereby affirm under -penalty of perjury that I am exempt from the Contractor's State I certify that in the performance of the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree that, if I should become subject to the any structure, prior to its issuance, also requires the applicant for the permit to file a workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the comply with those provisions. Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division _ 3 of the Business and Professions Code) or that he or she is exempt therefrom and the( Date: r "Z — -Applicant: basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for al — L_ — permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO (_) 1, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to within one year of completion, the owner -builder will have the burden of proving that the conditions and restrictions set forth on this application. he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made, each person at whose (_) I, as owner of the property, am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' issued as a result of this application , the owner, and the applicant, each agrees to, and State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to the work being performed under or the Contractors' State License Law.). following issuance of this permit. (_) I'am exempt under Sec. . B.&P.C: for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's N Lender's Address: I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Dite: `Z—fi Signature (Applicant or Agent): t Signature Date: 11/2/2016 Application Number: . BCOM2016-0049 Owner: . Property Address: 78370 HIGHWAY 111 STE 140 POINT HAPPY REALTY APN: 604050068 8665 WILSHIRE BLV STE 410 Application Description: MIRACLE EAR / T. 1. NEW WALLS, ELECTRICAL, SPRNKLERS BEVERLY HILLS, CA 92253 Property Zoning: Application Valuation: $8,000.00 Applicant: Contractor: TENANT IMPROVEMENT CO TENANT IMPROVEMENT CO 75-400 20TH AVENUE 75-400 20TH AVENUE SKY VALLEY, CA 92241 SKY VALLEY, CA 92241 (760)408-5473 Llc. No.: 538824 Detail: TENANT IMPROVEMENT MIRACLE EAR PER 2013 CBC CODES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF 101-0000-42403 0 $114.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF, PC 101-0000-42600 0 $88.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-426000 $5.07 Total Paid for MECHANICAL: $17.74 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $45.60 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 1$36.48 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141.36 Total Paid for REMODEL: $275.12 DESCRIPTION ACCOUNT QTY AMOUNT SMI - COMMERCIAL 101-0000-20308 0 $2.24 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.24 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin tt Qty of b Quinta Building & Safety Division Permit 1 78-495 Calle Tampico �y La Quinta, CA 92253 - (760) 777-701,2 �1 Building Permit Application and Tracking Sheet OCT p 7 Project Address: 7 g 3%oCITY Owner's Name: Co A.P.Number: (ff —��—.: ti Address: ®�VELOPA Legal Description: City, ST, Zip: Contractor: 1 /vAi�1 e P � ele hone: TP Address: 7 92pro A Project Description: City, ST, Zip: 5ky V RLL. 0,4 Pi7AVi . SIM A L�- e 0ne Tleh •7 0 d P g�.S- � � w S .a w A u � S State Lic. # : S3 S S.Zy City Lic. #.: a car r - Z. -S f2 ��k �2 � 'CA 0 Arch., Engr., Designer: c -A L Address: City, ST, Zip: Telephone: n Ca iructi n Type:Occupancy: YP a Lic. i State c.# •c to 0ProJet ryP (circle one • New Add'n Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project. APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . :PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading IN JfOUSE:- '•d Reyiew, ready for correctionstiissuc Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks_ Appr Date of permit issue School Fees, 1 Total Permit Fees N%' Permit Number: BCOM2016-0049 Applied: 10/7/2016 Issued: Status: UNDER REVIEW Parent Permit: Parent Project: Details: Description: MIRACLE EAR / T.I. NEW WALLS, ELECTRICAL, SPRNKLERS Approved: Site Address: 78370 HIGHWAY 111 STE 140 Finaled: City, State Zip Code: LA QUINTA, CA 92253 Applicant: TENANT IMPROVEMENT CO Owner: POINT HAPPY REALTY Contractor: TENANT IMPROVEMENT CO SENT DATE I RETURNED I DUE DATE I TYPE I CONTACT I STATUS I REMARKS Printed: Friday, 07 October, 2016 1 of 1, ■-J' �L"!CJ SYST[MS Wet ti �t V � , P.O. BOX 1 504 BUILDING & SAFETY DEPARTMENT OFTl9 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-701 1 NON RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/19/2016 STATUS: FIRST REVIEW PLAN CHECKED BY: J JOHNSON - TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 78-370 HWY 111 STE 140 DESCRIPTION: T.I. APPLICANT: POINT HAPPY PLAN CHECK #: BCOM2016-0049 This submittal has been checked for compliance with the 2013 California Building, Mechanical, Electrical, Plumbing, and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for following items are included: correction: REDLINED SET 1sT. P/C, 2 NEW REVISED ✓ 2 SETS OF PLANS 1ST. P/C SETS THIS CORRECTION LIST THIS CORRECTION LIST / RESPONSES mv F LA QUINTA COMMUNITY DEVE DO NOT accept any resubmittal unless ALL of the INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and . Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Non Residential Plan Check Correction List (os) t Coversheet The 2013 California Building; Mechanical, Plumbing,. Electrical Codes, California Green Building Standards Code, and Energy Code (i.e.; 2012 IBC, UMC, UPC, and 2011 NEC, as amended by the State of California) were used as the basis of our review. Our comments follow on the attached list. The basis of this plan review is the following codes: The 2013 California Building Code, 2013 California Mechanical Code, 2013 California Plumbing Code, 2013 California Electrical Code, 2013 California Energy Code, and 2013 California Green Building Standards Code, as applicable. The plan review .comments are attached. The 2013 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy Code (i.e., 2012 IBC, UMC, UPC, and 2011 NEC, as amended by the State of California) were used as the basis of our -review. Please note that our review has been completed and we have no further comments, however, we bring the following to your attention: In order to expedite the permitting process, we have made annotations (in red ink) to sheet7T A2�1. and S 01 2. As a condition -of -approval the applicant shall provide you with fully executed special, inspectic and testing forms_prior.to issuance of the building permitt We have enclosed the above noted documents bearing our review stamps for your use. Please call if you have any questions or if we can be of further assistance. OCCUPANCY & BUILDING SUMMARY: Occupancy Groups: B. Type of Construction: V -B Sprinklers: Yes Stories: 1 Area of Work (sq. ft.): 808 sq. ft. GENERAL INFORMATION: A. The following comments are referred to the 2013 California Building, Mechanical, Plumbing, Electrical Codes, California Green Building Standards Code, and Energy.Code (i.e., 2012 IBC, UMC, UPC, and 2011 NEC, as amended by the State of California). 'B. Respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which details, specification, or calculation shows the required information. Your complete and clear responses will expedite the re -check and hopefully, approval of this project. C. There may be other comments generated by the Building Division and/or other City departments that will also require your attention and response. This attached list of comments, then, is only a portion of the plan review. Contact the City for other items. I D. Please be sure to include the architect and engineer's "wet" stamp and signature on all sheets of the drawings and on the coversheets of specifications and calculations per CBPC 5536.1 and CBPC 6735. This item will be verified prior to plan approval. E.T he.following comments, numbers per the original list, require further response and revision Note that the format includes a restatement of the original comment followed by the new o clarifying 'recheck comment in a separate bolded and italicized paragraph. Any new comments are added at the end of the previous'list and are also bolded and.italicizedl ARCHITECTURAL COMMENTS: Al. Fire Department review and approval is required for (A, E, H, I, L, R occupancies)(high rises). Occupancy Group: A2. Specify on floor plans uses of all rooms or areas. Occupant Load A3. Per CBC. 1004. 1.1 the design occupant load shall be the combined occupant load of all rooms, areas, or spaces.. Please.show this on the plans. A4. Per CBC 1004.3 all assembly occupancies shall have their occupant load posted near the main exit. Please show this on the plans. Per CBC 1004 the occupant loads for all uses shall be determined by CBC Table 1004.1.2. Means of E ess: General 4 A5. Identify the function of each room (per CBC Table 1004.1.1), the area of each room, the occupant load factor of each room (per CBC Table 1004.1.1), and the total number of occupants in each room. Note that rooms with more than 49 occupants require two means of egress. CBC 1021.2 A6. Under the Occupancy Calculations Section, correct the calculation for the."total occupants". CBC 1004.1.2. Doors AT Provide specifications for the door hardware (i.e., lever type, push-pull, panic, etc) to comply with disabled access requirements.'(CBC 11B-404) Interior Finishes A8. Note on plans or finish schedule: "Wall, floor and ceiling shall not exceed the flame spread classifications in CBC T-803.9 r MECHANICAL COMMENTS: General M1,. Per CMC 112.2 please provide complete mechanical plans that include, but are not limited to, the following: a) The locations of all mechanical equipment such as, ducts, vents, ELECTRICAL COMMENTS: Switches El. Show the locations of all switches and switched receptacles per CEC 210.52. 1 • 1. Written Responses to: Plan Check # BCOM2016-0049 Instructions 1. ok ' 2. ok 3. ok 4. ok 5.ok Coversheet 1. We don't have a sheet T or A2.1 or S 1.1 2. There is no special inspections required Occupancy and Building summary re -written to match yours, see sheet Al 1 General Information: A. ok B. written response letter provided C. ok D. Exemption permitted under CBPC 6745 for alterations that do not affect the structural safety of the building. There is also an exemption permitted to.licensed contractors CBPC 6737.3. E. ok Architectural Comments A1. Fire department has approved A2. Specified in Room Schedule sheet A2 A3. Occupancy Load shown on Sheet Al A4. ' Shown on Sheet A2 Proposed Floor Plan A5. Table shown on Sheet Al (no rooms exceed 49) A6. Table on Sheet Al shows total occupants A7. Lever type noted on sheet A2 "Notes" A8. noted on sheet A2 "Notes" M1. Mechanical plan provide on M1 E1. switches and switched receptacles shown on sheet M1 (Electrical Plan)