Loading...
BSIG2016-001778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BSIG2016-0017 Property Address: 78962 HIGHWAY 111 APN: 643080008 Application Description: MC DONALDS / 5 SIGNS Property Zoning: Application Valuation: $12,000.00 Applicant: DESIGN UA 12832 VALLEY VIEW ST #C GARDEN GROVE, CA 92845 TitY' °f 4 Q" DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: MCDON LDYCORP� r J 3800 KI ROMRPORT WYE#200 LONGBnAi '00 Contractor: C C K BUILDERS INC 625 WEST KATELLA AVENUE #2 ORANGE, CA 92867 (714)538-8200 Llc. No.: 855822 10/13/2016 --------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 855822 Daterf Contractor. OWNER -BUILDER DEC ION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for az permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors" State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's WORKER'S COMPENSATION DECLARATION I herebyffirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the o for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Seciion'3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5021797 UI certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /e,. 12./ r WARNING: FAILURE TO SECURE WORKERS'NOMPEVSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIM NALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Dam "`Q Signa�re(AA plican�torr`Agent C Application Number: BSIG2016-0017 Property Address: 78962 HIGHWAY 111 APN: 643080008 Application Description: MC DONALDS / 5 SIGNS Property Zoning: (714)538-8200 Application Valuation: $12,000.00 Date: 10/13/2016 Owner: MCDONALDS CORP 3800 KILROY AIRPORT WY #200 LONG BEACH, CA 90806 Applicant: Contractor: DESIGN UA C C K BUILDERS INC . 12832 VALLEY VIEW ST #C 625 WEST KATELLA AVENUE #2 GARDEN GROVE, CA 92845 ORANGE, CA 92867 (714)538-8200 ----------------------------------------------- Llc. No.: 855822 --------------------------------------------- Detail: REPLACE 2 MENU BOARDS PER 2013 CBC. OTHER SIGNS AND TRELLIS WILL BE SUBMITTED AT A LATER DATE. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE -YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1 $95.00 Total Paid for BLDG CITY STAFF - PER HOUR: $10S.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS S131473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 - DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $6.93 Total Paid for Credit Card Fee: $6.93 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $24.17 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 Total Paid for ELECTRICAL: $48.34 DESCRIPTION ACCOUNT CITY AMOUNT MONUMENT SIGN, EA ADDITIONAL 101-0000-42404 0 $24.66 DESCRIPTION ACCOUNT CITY AMOUNT MONUMENT SIGN, FIRST 101-0000-42404 0 $72.52 DESCRIPTION ACCOUNT CITY AMOUNT MONUMENT SIGN, FIRST PC 101-0000-42600 0 $133.43 Total Paid for SIGN: $230.61 (ity of La Qulita 5P Building 8t Safety Division Permit # 6 78-495 Calle Tampico ' La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet t -Project Address: P�„q2-- Al (�1 Owner's Name: A. P. Number: Address: p p ,�cAby _Legal.Description: City, ST, Zip: of/d� -- -, . .Corntractor• t Tele hone: �v Address: Project Description: City, ST, Zip: fTe.�. _ /� ]e h _ phone: o . lee is State Lic. # : C City Lic. #; Arch., Engr., Designer: Address: "`'G-!✓ . I [�/ ��(�1 C City, ST, Zip- TelehP 0 ne: Construction s on T Y �y R i e: cc ane Occupancy: P V Y: Cr/ P State Lic. 9: - Project type (circle one): New Add'n Alter RePair • Demo ,Name of Contact Person: C Sq. Ft.: #Stories: #Units: /f f ,Telephone # of Contact Person: Estimated Value of Project: Z Up 3g A LIC T: DO NOT WRITE BELOW THIS LINE L 0�li fl Submittal Req'd Rcc'cl TRACKING Z — 9 o 0 PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Tit!e 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical. Subcontactor List Called Contact Pcrson Plumbing. Grant Deed Plans picked up S.M.I. li.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"! Reyiew, ready for corrections/issue Developer ImpactiFee Planning Approval Called Contact Person A.1.P.P. Pub. Wks. Aper Date of permit issue school Fees, Total Permit Fees LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 9.2253 TRANSMITTAL TO: �YOUNG [ESGIL []VCA- t ' TODAY'S DATE: ❑REDLINED TRUSS _ � 71' PERMIT NUMBED, LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 9.2253 TRANSMITTAL TO: �YOUNG [ESGIL []VCA- ATTN: ❑REDLINED STRUCT TODAY'S DATE: ❑REDLINED TRUSS _ � 71' PERMIT NUMBED, PROJECT ADDRESS:iDZ []REVISED ENERGY []CORRECTION LIST []OTHER', 4 APPLICANT NAME: SUBMITTAL ROUND: INCLUDED HEREWITH fvlpLANS []REDLINED PLANS. RUCT ❑REDLINED STRUCT []TRUSS ❑REDLINED TRUSS []SOILS []REDLINED SOILS DENERGY []REVISED ENERGY []CORRECTION LIST []OTHER', BUILDING &SAFETY DEPARTMENT (760)777-7125 FAX (760) 777-7011 []COMPLETE PLAN- CHEGK/N,0-ST.RUCTURAL DUE DATE: BIN NUMBER: UmhoweL []REVISED PLANS ❑REVISED STRUCT []REVISED TRUSS ❑REVISED SOILS ❑APPROVED PLANS []APPROVED STRUCT DAPPROV.ED TRUSS []APPROVED SOILS []CUSTOMER RESPONSES -BUILDING DEPARTMENT USE ONLY- -GREEN -SHEET TO< QCDD 0(w/Plans), []PUBLIC WORKS []COVE CHECK (w/Application) ASSIGN -NON=STRUCTURAL TO COMM, ENTS: 4 1 WU s p a iv u` y of'f Permit Number: BSIG2016-0017 Applied: 9/26/2016 Issued: Status: UNDER REVIEW Parent Permit: Parent Project: Details: Description: MC DONALDS / 5 SIGNS Approved: Site Address: 78962 HIGHWAY 111 Finaled: City, State Zip Code: LA QUINTA, CA 92253 Applicant: DESIGN UA Owner: MCDONALDS CORP Contractor: <NONE> it 1 y pp ��'N. J� ,��Zm. -41-11N, SENT DATE RETURNED DUE DATE TYPE CONTACT STATUS REMARKS DATE Review Group: BLDG 1ST (2WK) 9/28/2016 T 10/10/2016 1ST BLDG NS (2 WK) BUILDING BUCKET Notes: YOUNG 9/28/2016 10/10/2016 1ST BLDG STR (2 WK) ENGINEERING Notes: 10/7/2016 1ST PLANNING (2 WK) PLANNING BUCKET Notes: Printed: Monday, 03 October, 2016 1 of 1 (7b IVSY;TF-ts ° Twit " P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT c �Sw OF T19 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX 760 777-701 1 NON RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/7/2013 STATUS: FIRST REVIEW PLAN CHECKED BY: J JOHNSON' TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 778-962 HWY 111 DESCRIPTION: REPLACE MUNU BOARDS AND PRESALES BOARD APPLICANT: Mc DONALDS PLAN CHECK #: BSIG2016-0017 This submittal has been checked for compliance with the 2013 California Building, Mechanical, Electrical, Plumbing, and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 3 SITE PLANS 13'.'P/C 3 SETS STRUC DETAILS 1 ST. P/C 2 SETS STRUC CALCS 1 ST. P/C THIS CORRECTION LIST DO NOT accept any resubmittal unless ALL of the following items are included: BUILDING DEPARTMENT STAFF: REDLINED SITE PLANS 1 P/C, 2 NEW REVISED SETS REDLINED STRUC DETAILS 1sT. P/C, 2 NEW REVISED SETS REDLINED STRUC CALCS IS. P/C, 2 NEW REVISED SETS THIS CORRECTION LIST /W RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Non Residential Plan Check Correction List (os) Page 1 of 2 �;41 City of La' Quinta Professions Code Section 5536. Resubmittals will. not be accepted with signatures missing. 5) Return this list, your written responses, and all. documents listed above with your resubmittal. SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code '5536. Resubmittals will not be accepted with signatures missing. 2) Note on Plans: "All construction shall comply with the 2013 California Building, Mechanical, Electrical, .Plumbing, and Energy Codes and the La Quinta Municipal Code." Remove notes referencing other Codes. 1) Show on plans the Duct, Plenum, Hood and Flashing requirements specified in Chapter 5 of the California Mechanical Code. (CMC §508.1 through 508.9) Grease ducts serving a Type -I hood shall be constructed and installed in accordance with Chapter 5, Section 508. SECTION I — STRUCTURAL SEE ATTACHED Important note to Engineer of Record: These corrections require structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include (2) two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose pages will not be assembled by the Building Department.. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2y Provide contractor information to complete building permit application form 3) .Provide a current Certificate of Workers Compensation Insurance covering this project. 4) Provide proof of current City business license. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2 City of La Quinta Building and Safety Department Plan Check Corrections Strums � , Mc Donald's Signs 78962 High Way 111 La Quinta, California 1 -GENERAL Engineer: Ben Phan Plan Check No.: BSIG2016-0017 (1st check) Date: 10/7/2016 ❑.1 Plans are too incomplete to review at this submittal. Provide complete plans for next review. ®.2 Plan are incomplete. Please complete the plans but respond to all comments. Due to the incomplete nature of the plans additional corrections may apply on subsequent reviews. ®.3 Resubmit redlined plans for next review. Failure to resubmit these plans may cause delays, a new review, and/or additional plan review fees. ®.4 Respond to each of the below items with a written commentary as to where and how the requirement was met. Respond to redlined items on the redlined set with written commentary on the returned set or in the body of the responses 3 - STRUCTURAL OBSERVATION ®.1 Specify on the plans that structural observation per CBC 1704.5 is required. Note this in the structural notes or on both framing plans. ® Additional Comments: 1. Sign designs fall under section 29.4 of ASCE-10 for loading criteria. 2. Provide calculations for the Menu board cantilevered column, k=2.1. Welding design for column to base plate and revise detail accordingly. 3. Larger text on detail so it can be more easily read. 4. Clearance Bar and Order Here Canopy are open structures and will have wind uplift loading. 5. Revise spreadsheet information and equations for 2013 CBC values. 6. CBC table 1806.2 provides min values of soils. The city value for bearing is 1500psf unless geotechnical information is provided by licensed geotechnical engineer. 7. Is Clearance Bar designed for breakaway condition provide calculations ? 8. Special Inspection required for 3000psi concrete. If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations from this submittal plus two complete, bound copies of the revised calculations for review and approval. Providing only a few supplemental, revised pages will not be accepted and will delay approval of this project. Provide a detailed response list showing specifically where the comments are addressed in the calcs or the plans. Unspecific responses will not be rechecked and will be grounds to send back the plans for another round of review. We would encourage you to be very specific in your response. Please incorporate requested corrections into plan sets and reprint. Plan Reviewer. Joe Venuti, P.E. Phone No.: 760-772-5107 e-mail. LQPC@valuengr.com 77-C , t/` iJ try cic iia i)x�; Ste: l4 Palr aQ,#sed , c�1 42,214�1,� o@valuengr;om WebwWwivaJ Letter of Transmittal To: City of La Quinta Today's Date: 10-7-16 78-495 Calle Tampico City Due Date: 10-10-16 La Quinta, CA 92253 Project Address: 78962 Hiqhwav 111 Attn: Ramses Sevilla We are forwarding: Includes: # Of Copies: Submittal: ❑ By Messenger Descriptions: Plan Check #: BSIG2016-0017 1 St ❑ 4th ❑ 2nd ❑ 55th ❑ 3rd ❑ Other: ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Copies: ❑ Structural Plans ❑ Revised Struct. Plans ❑ Structural Calculations ❑ Revised Struct. Calcs ❑ Truss Calcs ❑ Revised Truss Calcs ❑ Soils Report - Update ❑ Revised Soils Report O Structural P/C Responses ❑ 1 / Comments Approved Structural Plans O 1 Redlined Structural Plans ❑ Approved Structural Calcs O 2 Redlined Structural Calcs 13_Approved Truss Calcs E3 —Redlined Truss Calcs ElApproved Soils Report 13Redlined Soils Reports ❑ Other: Comments: Structural content is not sapproyable. a+16,1, h Zc� S�rUG�c7�� �a rnme t1+ 1►s-t-• Transit Per Diem= Admin Time = .25 HR Structural Engineer/Principal Review Time = HR Plan Review Engineer Time = 1.25 HR This Material Sent for: ❑ Your Files ❑ Your Review ❑ Checking Other: ❑ ❑✓ Per Your Request ❑ Approval ❑ At the request of: By: Joe) 772-5 RE ' LIVED Office: Q (760) 772-5107 �, Other: ❑ OCT 0 5 2016 CITY 01= LA QUI, aTA COMMUNITY DEVELOPMENT I NON RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/7/2013 STATUS: FIRST REVIEW PLAN CHECKED BY: J JOHNSON TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 778-962 HWY 111 DESCRIPTION: REPLACE MUNU BOARDS AND PRESALES BOARD" APPLICANT: Mc DONALDS PLAN CHECK #: BSIG2016-0017 This submittal has been checked for compliance with the 2013 California Building, Mechanical, Electrical, Plumbing, and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for correction: REDLINED SITE PLANS 1sT. P/C, 2 NEW REVISED SETS 3 SITE PLANS 1sT. P/C REDLINED STRUC DETAILS 1sT. P/C, 2 NEW 3 SETS STRUC DETAILS 1sT. P/C REVISED SETS 2 SETS STRUC CALCS 1 ST. P/C REDLINED STRUC CALCS IS. P/C, 2 NEW THIS CORRECTION LIST REVISED SETS THIS CORRECTION LIST /W RESPONSES t DO NOT accept any resubmittal unless ALL of the following items are included: INSTRUCTIONS TO APPLICANT: 1) • Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint. Plans and%or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Non Residential Plan Check Correction List (os) Pagel of 2 F P.O. Box 1 504 BUILDING & SAFETY DEPARTMENT OFTl9 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX 760 777-7011 NON RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/7/2013 STATUS: FIRST REVIEW PLAN CHECKED BY: J JOHNSON TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 778-962 HWY 111 DESCRIPTION: REPLACE MUNU BOARDS AND PRESALES BOARD" APPLICANT: Mc DONALDS PLAN CHECK #: BSIG2016-0017 This submittal has been checked for compliance with the 2013 California Building, Mechanical, Electrical, Plumbing, and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for correction: REDLINED SITE PLANS 1sT. P/C, 2 NEW REVISED SETS 3 SITE PLANS 1sT. P/C REDLINED STRUC DETAILS 1sT. P/C, 2 NEW 3 SETS STRUC DETAILS 1sT. P/C REVISED SETS 2 SETS STRUC CALCS 1 ST. P/C REDLINED STRUC CALCS IS. P/C, 2 NEW THIS CORRECTION LIST REVISED SETS THIS CORRECTION LIST /W RESPONSES t DO NOT accept any resubmittal unless ALL of the following items are included: INSTRUCTIONS TO APPLICANT: 1) • Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint. Plans and%or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Non Residential Plan Check Correction List (os) Pagel of 2 City'of La Quinta Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. , 5) Return this list, your written responses, and all documents listed above with your resubmittal. SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's narne and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code 15$36. Resubmittals will not be accepted with signatures missing. 2) Note on Plans: "All construction shall comply with the 2013 California Building, Mechanical, Electrical, Plumbing, and Energy Codes and the La Quinta .Municipal Code." Remove notes referencing other Codes. 1) Show on plans the Duct, Plenum, Hood and Flashing requirements specified in Chapter 5 of the California Mechanical Code. (CMC §508.Lthrough 508.9) Grease ducts serving a Type -I hood shall be constructed and installed in accordance with Chapter 5, Section 508. SECTION I STRUCTURAL SEE ATTACHED Important note to Engineer of Record: These corrections require structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include (2) two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose pages will not be assembled by the Building Department. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide contractor information to complete building permit application form. 3) Provide a current Certificate of Workers Compensation Insurance covering this project. 4) , Provide proof of current City business license. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2