05-3265 (CSCS)
r,: 'P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 05-00003265 Owner: '— 79700 HIGHWAY 111 DUNES BUSINESS PARK LLC, THE 649-020-014-4 -31143 - 3550 W 6TH ST STE 400 NEW COMML - STORES & CUSTOMER SERVICE LOS ANGELES, CA 90020 REGIONAL COMMERCIAL 427389 &//�_,.rchitect or Engineer: - - - -- --- - - -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business an rofessionals Code, and my License is in full force and effect. License Class: B cense No.: 801773 Datd��Contractor. OWNER -BUILD DE RATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec: 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who.contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/16/06 Contractor: D Q BISHOP BUILDERS INC P.O. BOX 1746 KETCHUM, ID 83340 JUN 2 0 2006 (760)218-5801 Lic. .No.: 801773 CITyOFLAQU1N A -------'---------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 01641941-2005 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to.the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 700 of the Lebtlr�od , all ort w ly with those provisions. e: Ftp scant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATIq�% CO ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CINIL.FJf ES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relati�ing tion, and hereby authorize representatives of this co %nty to enter upon the above•mentiononpu l V Si ture (Applicant or Ag Application Number . . . 05-00003265 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 1787.50 Plan Check Fee 1161.88 Issue Date . . . . Valuation . . . . 427389 Expiration Date . . 12/13/06 Qty Unit Charge Per Extension BASE FEE 639.50 328.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,00.1-500,000 1148.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 69.00 Plan Check Fee 17.25 Issue Date Valuation' 0 Expiration Date 12/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 --------------"-------------------------------------------------------------- 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 Permit . . . ELEC-NEW COMMERCIAL Additional desc . Permit Fee ,185.00 Plan Check Fee 46.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 8500.00 ----------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 170.00 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 82.50 Plan Check Fee 20.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 3.00 6.0000 EA PLB ROOF DRAIN 18.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM- 9.00 1.00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH 7.50 LQEERMIT ` LQPERMIT Application Number . . . . . 05-00003265 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 •15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SHELL BUILDING "D", 8,500 SF TYPE V -N CONSTRUCTION, B/M PROPOSED USE. 2001 CODES. ALLOWABLE AREA BY SPRINKLERS = 8,000 SF X 3 = 24,000SF TOTAL ALLOWABLE AREA PER 503.3 EXCEPTION. **PERMIT DOES NOT INCLUDE TEMPORARY POWER, BLOCK WALLS, TRASH ENCLOSURES, COVERED PARKING AND SITE LIGHTING.** REFER TO 05-3262 FOR APPLICATION TRACKING NOTES. ---------=------------------------------------------------------------------ Other Fees . . . . ACCESSIBILITY PLAN REVIEW 116.19 ART IN PUBLIC PLACES -COM 2116.94 DIF CIVIC CENTER - COMM 807.50 ENERGY REVIEW FEE 116.19 DIF FIRE PROTECTION -COMM 272.00 STRONG MOTION (SMI) - COM 89.75 DIF STREET MAINT FAC -COMM 195.50 DIF TRANSPORTATION - COMM 14654.00 Fee summary Charged Paid Credited Due - ---------- - - ------ ---------- Permit Fee Total 2139.00 .00 00 2139.00 P1an.Check Total 1246.01 900.00 .00 346.01 Other Fee Total 18368.07 .00 .00 18368.07 Grand Total 21753.08 900.00 '.00 20853.08 LQPERMIT .. X TITLE 24 REPORT i Title 24 Report for: j 1 The Dunes Retail Center (Building "D") Parcel4 (Highway 111) . I La Quinta, CA i Project Designer: KKE Architects, Inc 525 East Colorado Boulevard Pasadena, CA 91101 626-796-8230 I Report Prepared By: ............... .SIA GARESTANI,. P.E._ ... - SPEC Engineering 6800 Owensmouth Ave. #140 JAN 0 9 `2007 Woodland Hills, CA 91303 j (818):592-6643 By CITY OF LA QUINTA - - BUILDING $ SAFETY DEPT, CITY OF LA QUINTA APPROVED BUILDING & SAFETy DEPT. FOR C N TRU ION g� t�_ iw: ' Job Number DA 2 e BY / 05-250 DATE Y Date: I 10/3/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415).897-6400. r— EnergyPro 3.1 By EnergySoft Job Number: 05-250 User Number: 3358 1-700 Aly //I - <we LL_ TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -MM Envelope Mandatory Measures 11 Form MECH-MM Mechanical Mandatory Measures 12 HVAC System Heating and Cooling Loads Summary 14 w 66 3.1 By Energysoft Job Number: 05-250 User Number: 3358 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME The Dunes Retail Center (Building "D") _— DATE 10/3/2005 PROJECT ADDRESS Parcel 4 (Highway 111) La Quinta BUILDING TYPE I Building: Permit* .. I —.. _.. PRINCIPAL DESIGNER - ENVELOPE KKE Architects, Inc DOCUMENTATION AUTHOR SPEC Engineering —__— ------------- — -- — - --------- _— - -.... -- -- -- I TELEPHONE 626-796-8230 jTELEPHONE (818) 592-6643'E — --- -- -- ------ ChecRed by/Date forcerrentA06o ,Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE OF PLANS IBUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 07-14-05 _ _ _ 8,531Sq_Ft. _ _ 15 _ — BUILDING TYPE NONRESIDENTIAL L J HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ALTERATION �_� EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building usin a pe mance compliance approach. DOCUMENTATION AUTHOR SIGNATURE DATE SIA GARESTANI P.E. (p p 0 —06 The Principal Designers hereby certify that the proposed buildin sign rielfesented in the construction documents and modelled for this permit application are consistent with all other forms worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed me the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH._ I �...� ❑ J 1.1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to j sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. ❑ ❑ R 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section. 5537.2 or 6737.3 to sign this document as the person responsible for Its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains.to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE. Indicate location on plans of Note Block. for Mandatory Measures ENV -1 Requir orms PRINCIPAL ENVELOPE DESIGNER - NAME SI AT LIC, NO. DATE KKE Architects Inc •'j► d .03 LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms_ Ittei-.------- - -- - - -- PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE —� LIC. NO. DATE MECHANICAL COMPLIANCE I Indicate location on plans of Note Block for Mandatory Measures—_—_-- — _— Required Forms M_E MECH-2 MECH-3 _-1, PRINCIPAL MECHANICAL DESIGNER - NAME I SIG NATU LIC. N0. DATE SIA GARESTANI P.E. Run Initiation Time: 1 3/05 10:59:03 Run Cod 28362 43 EnergyPro 3.1 By EnergySoft _ User Number 358 Job Number. 05-250 — — — `-- page:3 of 16 — — PERFORMANCE CERTIFICATE OF.COMPLIANCE Part 2 of 3 'PERF - The Dunes Retail Center Buildin T" i jDATE 10/3/2005 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r I Standard Proposed Compliance Ii ENERGY COMPONENT Design Design Margin a I Space Heating 2.18 2.11. 0.07 Space Cooling 63.44 63.30 0.14 Indoor Fans 16.46 16.18 _ 0.28 Heat Rejection 0.00 0.0 0.001 Pumps &' Misc. 0.0010.00 0.00 Domestic Hot Water 0.00 o.00 0.00 ..._I-._L-ighting--------------- --- ----50.-08 --...---- -- -----50-08 Receptacle 15.93 15.931 0.00 Process 33.86 33.86 0.00 TOTALS: 181.95 181.46 0.49 Percent better than Standard: 0.3% ( 0.3% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation (South)180d2g. Conditioned, Floor Area 8,53 sqft. Number of Stories 1 Unconditioned Floor Area o sgft. Number.of-Systems _ .. _. _ -.. . .............. ._ _ _ _- 3 :-Gond itioned-FootTint Area - - -0 scift.- - Number of Zones 3 Orientation Gross Area Glazing Area Glaiinp Ratio Front Elevation (South) 1,734 sgft- 1623 sgft. 35.9% Left Elevation (west 684 sgfL _ 0 sgft. 0.0% -Rear Elevation (North) _ 1,73a sgft. 0 sgft. 0.0% Right Elevation (East 1,701 sgfL �_ 3581 wM. 21.00/c Total - _ 5853 sgft. L --_ 981 sgft. Roof EL_8, sgn. F _Jsgn. o.o/.] Standard Proposed 1EEDTM Energy A Atmosphere Credit Lighting Power Density 1.700 w/,sgft. 1.700 wisgfL Savings vs. Title 241. 0.37% Prescriptive Env. Heat Loss 1,376 Btu/h 1,783 Btu/, Energy Performance Credi? o Points Prescriptive Env. Heat Gain .166,206 Btom-F 183,599 Btuih-F 1. excludes process and receptacle 2. see LEED able 8< or Ir -0 i Remarks: - - l Run Initiation Time: 10/03/0510:59:03 Run Code: 1128362343 EnergyPro 3.1 By Energysoft User Number: 3358 Job Number. 05-250 Page:4 of 16 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME DATE The Dunes Retail Center(Building "D" 10/3/2005 ZONE INFORMATION Floor Inst. Port Qrl-. Tailored Proc.'' Area LPD LPD Zredits System Name Zone Name Occupancy Type (sgft.) W/sf)1 (W/sf)l Is 2 .;,LPD M403 (WlsfY,- RTU -13 Building "D" Comp Bldg Retail/Wholesale 2,291 •1.700 2.000 RTU -14 Building "D" Comp Bldg Retail/Wholesale 3,120 "1.700 2.000 RTU -15 Building "D" Comp Bldg RetaillWholesale 3,120 '1.700 2.660 tin J� i5 T Via. Lr ;fi_ y t q } Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 items above:regwre Spada/ documentation -- EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST _ __ __- _..._. __..._... _a-••-, ,..,,,.,,, ".Y .&MIILIV11 {V II IC ILVIII.1 aPccllleu In ims cnecKnst. i nese items require special written Justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines M tha nrianllnrw fhn iu�MC.. �1:. ...: _ -1� _ �. .- - -_ _.._ ..._, .-j , ,. ,,,,,,,,,,,y ,,. �`„a„ vv,u, w,oQ %,vlllPncs uaseu un the adequacy OT the speClal ustiTlcatlon and documentation submitted. Plan Field The Zone "Building "D'"' has a -Display Perimeter Credit of 91 ft. i ne exceptional features listed In this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Run Initiation Time: 10103/0510.59.03 Run Code: 1128362343 EnergyPro 3.1 By EnergySoft User Number. 3358 Job Number: 05-250 Paae:5 of 16 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME The Dunes Retail Center(Building "D" DATE 10/3/2005 OPAQUE SURFACES , ,.v �oVa.l V�i11111VP1G 1 Glazing Type VIM. Location / Comments 1 2 3 -4- Window Window Window # Surface Framing Act. Type Type Area U -Fac. Am. Tilt Solar Gains y/N Form 3 Reference Location / Comments 1 Roof Wood 2,291 0.035 0 0 1X11 R-30 Roof R.30.2x12.16 Building "D" 2 Wall lWood 684 0.065 1 270 90 1X11 R-19 Wall -1'9.2x6.16 Building 'D" 3 Wall Wood .575 0.065 90 90 1XIR-19 Wall .19.2x6.16 Building "D" 4 Wall Wood 1,111 0.065 180 90 1xj R-19 Wall W.19.24.16 Building 'D" 5 Roof Wood 3,120 0.035 0 0 R-30 Roof R.30.202.16 Building "D" 6 Wall Wood 768 0.065 90 90 IXI R-19 Wall .19.26.16 Building 'D" 7 Wall Wood . 1,734 0.065 0 90 R-19 Wall W.19.24.16 Building "D" 8 Roof Wood 3,120 0.035 0 0 X 11 R-30 Roof R.30.202.16 Building "D" EXTERIOR SHADING # 1 Exterior Shade Type None Window SHGC H t. Wd. 0.76 10.5 17.0 Overhang L x i 4.0 0.1 4.0 4.0 Left Fin Right Fin LDist. L 2 None 0.76 10.5 17.0 4.0 0.1 4.0 4.0 3 None 0.76 10.5 30.0 11.0 0.1 11.0 11.0 4 None 0.76 10.5 14.2 11.0 0.1 11.0 11.0 5 None 0.76 10.5 14.2 FENESTRATION SURFACES 0.1 11.0 11.0 aae Assernmea uiazin ~^�"'y �yl� vl ��^ allu t v,vvv sqn vermat glazing men Nmu cenmcation is required g # Type - ---- -- - -- -- -- -- • �-�--•-- Area U -Fac. Act. Am. .-•... rrv. SHGC , ,.v �oVa.l V�i11111VP1G 1 Glazing Type VIM. Location / Comments 1 2 3 -4- Window Window Window 179 179 323 1.190 90 1.190 90 1.190 180 0.82 .0.82 0.82 Sin le Clear Default NM Single Clear Default NM Sin le Clear Default NM uildin "D" uildin "D" uildin "D" luilding"D" 5 Window - - - Window ` 15o 150 1 1.190 180 1.190 180 0.82 0.82 Sin le Clear Default NM Sin le Clear Default NM uildin 'D" EXTERIOR SHADING # 1 Exterior Shade Type None Window SHGC H t. Wd. 0.76 10.5 17.0 Overhang L x i 4.0 0.1 4.0 4.0 Left Fin Right Fin LDist. L 2 None 0.76 10.5 17.0 4.0 0.1 4.0 4.0 3 None 0.76 10.5 30.0 11.0 0.1 11.0 11.0 4 None 0.76 10.5 14.2 11.0 0.1 11.0 11.0 5 None 0.76 10.5 14.2 11.0 0.1 11.0 11.0 Initiation Times 10/03/05 10:59:03 Code:Run Run 1128362243 EnergyPro 3.1 By EnergySoft User Number. 3358 Job Number: 05-250. Page:6 of 16 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME _ The Dunes Retail Center (Building " D SYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? - SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3 COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS RTU -13 RTU -14 Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume _ .. —'-'--'No No Constant Tem Constant Tem 'n/a Air Balance Auto Fixed Tem Non-Inte 781 dm Heat Pum 3.30 COP Packa ed DX 10.3 EER CARRIER 50HJQ009 Yes No Ducts in Attic 4.2 Ducts in Attic 4.2 No DATE 10/3/2005 n/a n/a Yes Yes CODE TABLES: Enter code from table below into columns above. 0.0 kW 0.0 kW HEAT PUMP THERMOSTAT? Constant Volume Constant Volume ISOLATION ZONES NO ELECTRIC HEAT? S: Prog. Switch No No I: Inlet Vanes Constant Temp Constant Tem Constant Temp Constant Tem n/a n/a sr,: Air Balance Air Balances}, ; Auto Auto 0: Other C: Curve Fixed Tem Non-Inte Fixed Tem Non -Irate 1064 cfm 1064 elm HIGH EFFICIENCY? Heat Pum . Heat Pum 3.30 COP 3.30 COP C: Outside Air Cert. Packaged DX Package DX CFM. 10.3 EER 10.3 EER CARRIER 50HJQ012 CARRIER 50HJQ012 SEALED DUCTS IN CEILING/ROOF SPACE Yes Yes Control See Section No No Ducts in Attic 4.2 Ducts in Attic 4.2 Use 0 -nim •C' / Ducts in Attic 4.2 Ducts in Attic 4.2 No Run Initiation Time: 10/03/0510:59:03 Run Code: 1128362343 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:7 of 16 CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes VAV MINIMUM POSITION CONTROL? 0: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD SIMULTANEOUS HEAT/ COOL? Y: Yes M: Manual Timer 0: Other C: Curve HEAT AND COOL SUPPLY RESET? N: No VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance A: Auto A: Air Enter Outdoor Air PIPE INSULATION REQUIRED? C: Outside Air Cert. G: Gravity W: Water CFM. PIPE/DUCT INSULATION PROTECTED? M: Out. Air Measure D: Demand Control N: Not Required EC: Economizer Note: This shall be no less than Col. H on SEALED DUCTS IN CEILING/ROOF SPACE N: Natural Control See Section MECH-3. 144e3 U. -VI UuIlding Department LD\ �fyt�.Y1.� XSF �<1 t.. L�. /r tjT Use 0 -nim •C' / ,-.: , Run Initiation Time: 10/03/0510:59:03 Run Code: 1128362343 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:7 of 16 ]MEtHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-21 I PROJECT NAME T . he Dunes Retail Center (Building T") DATE 10/3/2 005 ICHILLER AND TOWER SUMMARY Fan Type Constant Volume Constant Volume Motor Location Draw -Through Draw -Through CFM 3,400 4,0001 Efficient J�nsj Tot. M j BHP PUMPS motor Eff. Drive � Pump Control . .. . ....... BHP Equipment I quipment 0 ty. I -71i MW AY ANK INSUL. I Ext. .---R-V 1. Energy Factor or Recovery --Efficiency Standby Loss or --Pilot- -- System Name.____Systern.Type I Distribution Type Qty Rated ---Input -(Gals;) i Vol. CENTRAL SYSTEM RATINGS System Name CARRIER 50HJQ009 CARRIER 50HJQ012 Ant_e_MTYP_� Packaged DX Packaged DX Qtv. I 2 Output _ 96,000 114,000 HEATING Aux. kW 0.0' 0.0 ' Eff. _Output 3.30 COP 3.30 COP mt: 102,3001 119,4001 Sensible 77,20 89,80 COOLING _Efficiency 10.3 EER 10.3 EER Economizer Type Fixed Temp (Non-InteE) Fixed Temp (Non.-Integ) ICENTRAL SYSTEM Font SI IMMAIRV AUR& FAN RETUF N FAN System Name CARRIER 50HJQ009 CARRIER 50HJQ012 Fan Type Constant Volume Constant Volume Motor Location Draw -Through Draw -Through CFM 3,400 4,0001 BHP 0.80 0.80 fiotT Motor — Eff. 77.0%. 77.0% Drive lEffff. 97.0% 97.0%] CFM none none BHP Motor Eff. Drive Eff, User Number. 3358 LT Paae:8 of 16 3.1 By EnergySoft Job Number: .251 MECHANICAL EQUIPMENT SUMMARY PROJECT NAME The Dunes Retail Center(Building T") ZONE TERMINAL SUMMARY WAV TERMIN =nnr%UQ I rAN JUMMAKY Al BOX Min. CFM Reheat Coil System Type Ratio Type lDeltaT Part 2 of 2 MECH-2 DATE ._._.___- Moto Drive CFM I BHP Eff. Eff. I I TvDe Output Motor Drive Motor Drive Room Name Qtv. CFM BHP Eff. Eff. Room Name city. CFM BHP Eff. Eff. Run Initiation Time: 1010310510:59:03 Run Code: 1128362343 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number. 05-250 pa 9oi16 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE The Dunes Retail Center(Building T") 10/3/2005 MECHANICAL VENTILATION RA a a o 0 0© o 0 0 0 ZONE/SYSTEM Building"D" RTU -13 Building "D" RTU -14 Building "D" RTU -15 'Um" 1REA (SF) CFM PER SF mil CFI (B x 2,29 0.23 15.0 781 3,120 0.23 15.0 1,064 3,1201 0.23 15.0 " OCCUPANCY BASIS NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) 52. 15.0 781 Total 70.9 15.0 1,064 Total 70.9 15.0 1,064 Total ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME I DATE The.Dunes Retail Center Building T") ; , 10/3/2005 DESCRIPTION - _ ^ _ —_ �Dit igner Enforcement _ �X; § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article i 3. FXJ§ 118(c) All Insulating Materials shall be Installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. i - -§.117(a). All-Exterior.J.oints and open in gs.in_the.building that. are_observable sources of.air.. i leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. ! --- ----- ---- — 0 § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and I fire doors). X❑ § 116(a).1 Manufactured Doors. and Windows installed shall have air Infiltration rates not exceeding those shown In Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. l^J §118(e) Demising Walls In Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have Insulation with an Installed R -value of no less than R-11 between framing members. . I ! I � _ I I i - EnergyPro 3.1 By EnergySoft User Number: 3358_— — _ ,lob Number: 05-250 __ —_ ___ Page: 11 of 16 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT -NAME DATE The Dunes Retail Center(Building T") 10/3/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies XI §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. ►"` r' FX�§ 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with / ✓ Standards Section 123. § 124 Air handling duct systems shallbe installed and insulated in compliance with --�---- - --'- Sections 601, 603 and 604 of the'Uniform Mechanical Code. - Controls § 122(e) Each space conditioning system shall be installed with one of the following: a§ 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is Interrupted; or 122 e 1 B An occu anc sensor tcontrol the operating _ ._ _ ..§•._ - P Y, o _ p . g penod of the system; or �10 . N 0 § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. 0 ' § 122(e)2 Each space conditioning system shall be Installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. - F$122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation. zones. Each zone: shall not exceed 25,000 square feet; shall be. provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other Isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling Is shut off or reduced to a minimum. X § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number. 3358 Job Number: 05-250 Page:12 of 16 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM - --- ---------- PROJECT NAME – DATE g The Dunes Retail Center (Buildin_ _. _ _ ,� 10/3/2005 f _ Description _ —_ _ _-_- Designer Enforcement - - Ventilation 0 § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at I ✓ the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers Interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. I — § 122(o All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. . § 121(f)l Air Balancing: The system shall be balanced in accordance with the National i / Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or 111 § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing Ilcensod C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person•with overall responsibility for the design of the ventilation system; or F § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and.displaying that quantity on a readily accessible display divice; or/�. § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 If a circulating hot water system is Installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)36 Lavatories In restrooms of public facilities shall be equipped with one of the – — following: r Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. j Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). i Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor i controls). EnergyPro 3.1 By EnergySoft User Number: 3358 _ — Job Number: 05-250 _ - Page:13 of 16 \:Tt. �� `y- yn F.. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE - -- _- The _Dunes_ Retail Center (Building. -D") 10/3/2005 _ ---- -- SYSTEM NAME RTU -13 i FLOOR AREA — --- ---- 2,291 NGINEERING CHECKS SYSTEM LOAD Number of Systems 1 -Heating System Output per System -- --- 96,000 Total Output (Btuh) 96,000 Output (Btuh/sgft) --- _41.9 Cooling System Output per System 102,300 Total Output (Btuh) 102,300 Total Output (Tons) 8.5 Total Output (Btuh/sgft) 44.7 Total.0utput (sgft/Ton) 268,7 Air System CFM- per. System 3,400 Airflow (cfm) 3,400 :..:4flo #fm/sgft) 1.48 Airflow. (cfm/Ton) 398.8 Outside Air ('/o) 23.0 - -Outside Air (cfm/sgft) - - - - - - -0:34 L Note: values EATING •§ 24.0 of Outside'Air 781 cfm 70.0 of 1112.0 / 78.5 of Outside Air —'? 781 cfm 1 74.6/61.8OF at ARI conditions YCHROMETRICS 59.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan _ Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 2,255 46,1751 9,89]3 L_97 3, 0 i 0 2,309 00 183 0 F-781 31,506 — 16,932 781 38,743 0 0 2,309 183 —82 330 _ 26,825 42 769 CARRIER 50HJQ009 88,885 3,235 Total Adjusted System Output (— 88,881 3,235 (Adjusted for Peak Design Conditions) L__.— TIME OF SYSTEM PEAK - Jul 3 pm j Heating Coil Supply Fan 3400 cfm 60,512 60,512 105.0 of --� Supply Air Ducts 105.0 of ROOMS 70.0 of J) Keturn Air uucts lirstream Temperatures at Time of Cc 83.2 / 65.8 of M 55.0 / 53.5 of 55.0 / 53.5 of User Number. 3358 Cooling Coil Supply Air Ducts. g Supply Fan 55.6 / 53.7 of 3400 cfm 49.5% R.H. ROOMS 74.0 161.6 OF Return Air Ducts Job Number. 05-250 14 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY NAME The Dunes Retail Center (Building" D" NAME RTU -14 INumber of Systems Heating System Output per System . 114,000 Total Output (Btuh) 114,000 Output (Btuhlsgft) 36.5 Cooling System Output per System 119,400' Total Output (Btuh) 119,400 Total Output (Tons) '9.9 Total Output (Btuh/sgft)d13.6 —22,794 Total Output (sgfUTon) rAir System CFM per System 4,000 Airflow (cfm) ' 4,000 Airflow (cf n/sgft) 1.28 Airflow (cfm/Ton) ' 402.0 II Outside Air (%) L outside Air (cfm/sgft) _— 26.6 6.34 Note: values above given at ARI conditions (EATING SYSTEM PSYCHROMETRICS 24.0 OF 57:2 OF ) Outside Air —0 - 1064 cfm 69.2 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 10/3/2005 FLOOR AREA 3.120 COIL COOLING PEAK COIL HTG. PEAK LCFM I Sensiblel Latent CFM I Sensible 6,698 137,396TJ 13,473 L 1,742 65,819 6,870 o 3,29 0 5064 41,807 —22,794 1,064 51,945 o _. _6,87 o 3,291 L-192943 36 267 124 346 CARRIER 50HJQ012 107,880 1,222 71,858 1 Total Adjusted System Output 10 1,222 71,858 (Adjusted for Peak Design Conditions) _ _ TIME OF SYSTEM PEAK C Jul 3 pm Jan 12 am 105.0 OF Heating Coil Supply Fan 4000 cfm 105.0 OF -� Supply Air Ducts 104.2 of ROOMS 70.0 OF >% Return Air Ducts 'i DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak I 112.0 / 78.5 OF 85.3 / 66.7 OF 55.0 ! 53.4 OF 55.0 / 53.4 of 310 Supply Air Ducts Outside Air 1064 cfm Cooling Coil Supply Fan 56.6/54.0 °F j 4000 cfm 49.8% R.H. ROOM' _ 0 74:01 OF F j 75.6 / 62.2 F r EnergyPro 3.1 By EnergySoft User Number 3358 Return Air Ducts Job Number: 05-250 Page: 15 of 16 HVAC SYSTEM HEATI, G AND COOLING LOADS SUMMARY PROJECT NAME DATE _ The Dunes Retail enter (Build "D''�_ 10/3/2005 — _ _ SYSTEM NAME —J FLOOR AREA RTU_15 � 3,120 —-_ NGINEERING CHECKS SYSTEM LOAD Number of Systems —_ �, COOLING P_ COIL COOLPEAK COIL HTG. PEAK _� CFM Sensible Latent J CFM I Sensible] Total Room Loads 3,37269,173 �_ 13,473 331 12,517 .1 Return Vented Lighting0 1 -_—�� [Heating System r Output per System --__-- ' 114,000 Total Output (Stuh) 114,000 Output (Btuh/sgft) 36.5 I Return Air Ducts j 3,459, 626 Return Fan _ 0i I 0 Ventilation j 1,064 42,710 22,69 1,064 52,654 Supply Fan 0 0 ,Coo' littg System Al oufpat per System 119,400 Totalgqutput(Btuh) —_ — 119,400 Total. utput (Tons) 9.9 Supply Air Ducts 3,459 626 Total . utput (BtuFUsgf)) TOTAL SYSTEM C Total F tput (sq :., on) 313.6 LOAD 118,8291 36170 66.422 — Air Systema CFM per S'v �l Ystem _ 4,000 (cfm) rat. 4,000 HVAC EQUIPMENT SELECTION -- -- - CARRIER50HJ0012 106,260 2,568 71,858 (cfm/sgft)1.28(cfm/Ton) ------ '. - 402.0 Llkl'rflow Total Adjusted System Output R.. -- (Adjusted for Peak Design Conditions) 06,260 _ 2,568] 71,858 �n TIME OF SYSTEM PEAK L_.":. Jul 3 pm � Jan 12 am, o ��, Outside Air (/o) ti< 26.6 — Outside Air (cfm/sgft) ,) 0,34 �: , Note: values above given at ARI conditions EATING.SYSTE PSY HR.OM TRICS Airstream Temperatures at Time of.Heatin Perak — j 24.0 OF 3Y 57.7 OF 105.0 OF .105.00F, Outside.Air Supply Air Ducts � ��*�/ 1064 cfm t *� Heating Coil Supply Fan _. 104.9 °F r 4000 cfm 1 ! ROOMS.] 69.9 OF 70`0 OF Return Air Ducts" } DOLING SYSTEM PSYCHROMETRICS; Airstream Tem eratures-at Time of Cooling Peak - 112.0 / 78.5 OF 84.7/-6, .5.6 OF 55.0 ! 53.4 OF 55.0 / 53.4 OF `µYJ Supply F� Draets Outside Air 4 I 1064 cfm Cooling Coil `Supply Fan (' ` 55.8t53.6 OF 4000 cfm o �O— SIF 49.9 /o R.H. 74.8/62.0 oF• iw!0/61.7 °F aF D rw uffi Mir DUCTS ,- EnergyPro 3.1 By EnergySoft User Number: 3358 Job. Number 05-250 r