07-0823 (CSCS)N
* r
P.O. BOX 1504 t
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
• "
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: f 07-00000823
Property Address: 79785 HIGHWAY 111
APN: 600-020-034- - -
Application description: NEW COMML - STORES & CUSTOMER SERVICE
Property Zoning: COMMERCIAL PARK
Application valuation: 442038
Applicant:
4R4+1=;rsc
Architect or Engineer:
7F. 4.
c-,1764
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Businesand Cionals Code, and my License is in full force and effect.
License Class:
B C9 nse No.: 436418
/Dat9 V VContract :
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):
(_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
. Date:
Owner:
CONSTRUCTION LENDING AGENCY '
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPEMMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/12/07
Owner:
KOMAR INV
23 CORPORATE PLZ
STE
247
NEWPORT BEACH, C
e
Contractor:
SEP 1 �oo�
BERGMAN.COMPANIE
HE
4300 EDISON AVE
E
CHINO, CA 91710
ClTYOpLgQU1NTA
pl ANCEDEPT.
(909)627-3651
Lic. No.: 436418
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate, of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier AMERICAN INTL Policy Number WC5312540
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to beco bject to the workers' compensation laws of California,
and agree that, if I should become bjec t orkers' compensation provisions of Section _
3700 of the Labo e, I hall fo with com ly v, those provisions.
1/bateq' t Q ✓�pplicant: G C_d
WARNING: FAILURE TO SECURE WORKERS' COMPETION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION,TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. -
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. .
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or ces ation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state th%-1., infor i is correct. I agree to comply with all
city and county ordinances and state laws relating t stru on, nd hereby authorize representatives
of th`iJ.unty to enterrupon the above-mentioned prp ion p os
Date! ^�"" dSignature (Applicant or Agen
Application Number . . . . . 07-00000823
------ Structure Information 9544 SF SHELL BLDG E
-----
Other struct info . .
. . . CODE EDITION O1BMP04E05EN
FIRE SPRINKLERS
MIXED-USE OCCUPANCY SHELL
OCCUPANT LOAD
.00
PATIO SQ FTG
1728.00
1ST FLOOR SQUARE FOOTAGE
9544.00
--------------------------------------------
2ND FLOOR SQUARE FOOTAGE
--------------------------------
.00
Permit
BUILDING PERMIT
Additionaldesc
SHELL BLDG "E"
Permit Fee
1840.00 Plan Check Fee
1196.00
Issue Date . . . .
Valuation . . . .
442038
Expiration Date
3/10/08
r
Qty Unit Charge
Per
Extension
BASE FEE
639.50
343.00 3.5000
----------------------------------------------------------------------------
THOU BLDG 100,001-500,000
1200.50
Permit . . .
ELEC-NEW COMMERCIAL
Additional desc .
Permit Fee . . . .
240.44 Plan Check Fee
60.11
Issue Date . . . .
Valuation . . . .
0.
Expiration Date
3/10/08
f
Qty Unit Charge
Per
Extension
BASE FEE
15.00
11272.00 .0200
------------------ 7 ---------------------------------------------------_-----
ELEC GARAGE OR NON-RESIDENTIAL
225.44
Permit . . .
MECHANICAL
Additional desc .
Permit Fee
187.50 Plan Check Fee
46.88
Issue Date
Valuation
0
Expiration Date
3/10/08
Qty Unit Charge
Per
Extension
BASE FEE -
15.00
6.00 9•.0000
EA MECH FURNACE <=100K
54.00
6.00 .16.5000
EA MECH B/C >3-15HP/>100K-500KBTU
99.00
3.00 6.5000
-----------------------------------------------------------------------------
EA MECH VENT.FAN
19.50
Permit . . PLUMBING
Additional desc .
LQPERMIT
LQPER11IIT
0
Application Number . . . . . 07-00000823
Permit . . . . . . PLUMBING
Permit Fee 117.00 Plan Check Fee
29.25
Issue Date . . . . Valuation . . .
. 0
Expiration Date . . 3/10/08
Qty Unit Charge Per
Extension
BASE FEE
15.00
6.00 6.0000 EA PLB FIXTURE
36.00
1.00 15.0000 EA PLB BUILDING SEWER
15.00
5.00 6.0000 EA PLB ROOF•DRAIN
30.00
3.00 3.0000 EA PLB WATER INST/ALT/REP
9.00
1.00 9.0000 EA' PLB LAWN SPRINKLER SYSTEM
9.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
----------------------------------------------------------------------------
3.00
Permit . . . GRADING PERMIT
Additional desc .
Permit Fee . . . . 15.00 Plan Check Fee
.00
Issue Date . . . Valuation . . .
. 0
Expiration Date 3/10/08
Qty Unit Charge Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
9,544 SF RETAIL SHELL BUILDING "E".
TYPE V -N CONSTRUCTION. 2001
CBC,CMC,CPC, 2004 CEC, 2005 ENERGY
CODES. **PERMIT DOES NOT INCLUDE.
TEMPORARY POWER, BLOCK WALLS, TRASH
ENCLOSURE, WATER FEATURES, GREASE
INTERCEPTORS AND SITE LIGHTING.**
NOTE: SUSPENDED CEILING, HVAC DUCTS &
LIGHTING INSTALLED Q 3 OF 3 SUITES.
----------------------------------------------------------------------------
Other Fees . . . . . . . . ACCESSIBILITY PLAN REVIEW
119.60
ART IN PUBLIC PLACES -COM
2190.19
DIF CIVIC CENTER - COMM
3073.16
ENERGY REVIEW FEE
119.60
DIF FIRE PROTECTION -COMM
429.48
i STRONG MOTION (SMI) - COM
92.82
DIF STREET MAINT FAC -COMM
1011.66
DIF TRANSPORTATION - COMM
29004.21
Fee summary Charged' Paid Credited
Due
Permit Fee Total 2399.94 .00 .00
2399.94
Plan Check Total 1332.24 900.00 .00
432.24
LQPER11IIT
0
Application Number . . 07-00000823
Other Fee Total 36040.72 ..00 .00 36040.72
Grand Total 39772.90 900.00 .00 38872.90
LQPERMIT
Corporate:
2992 E. La Palma Ave. Ste. A
[7:1Anaheim, CA 92806
1Tel: 714.632.2999
x: 714
www.mtglinc.com is h.632.2974
: 800.491.2990
MTGL Project #:
Ra—
Permit# 0`7- a
Report # PG I OF
San Diego/Imperial County
7313 Carroll Rd. Ste. G
San Diego, CA 92121
Tel: 858.537.3999
Fax: 858.537.3990
Dispatch: 888.844.5060
DAILY INSPECTION
REPORT
R
Inland Empire:
14467 Meridian Pkwy., Bldg. 2-A
Riverside, CA 92518
Tel: ' 951.653.4999
Fax: 951.653.4666
Dispatch: 800.491.2990
DSA/CITY File
DSA/OSHPD APPL #:
DSA / LEA #:
Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection. Reports of non-compliant conditions must be distributed immediately.
Separate reports shall be prepared for each type of special inspection, on a daily basis. Each report shall be completed and signed by the special inspector conducting the inspection.
PROJECT NAME� DATE
® e: fi ear
MET ❑ DID NOT MEET ❑
ARCHITECT
TIME ARRIVED TIME DEPARTED
0760 �315'
ENGINEER ry �� 6k
Ci
TRAVEL TIME • LUNCH TIME
Weather: C1 ea rTemp:
CONTRACTOR
y V1m
SUB CONTRACTOR t
INSPECTION -ADDRESS .:
�H+-�t 0-4 -
ADDRESS OF PROJECT
Li .
TYPE OF INSPECTION ❑ BA CH PLANTS 3 -MASONRY - — ❑ FIREPROOFING
❑ ENGINEERED FILL ❑ PT CONCRETE ❑ HIGH STRENGTH BOLTING ❑ ANCHOR/DOWEL
❑ FOUNDATION ❑ SHOTCRETE 9 WELDING ❑ NDE FIELD
❑ BACK FILL ❑ CONCRETE ❑ SHOP WELD ❑ NDE SHOP
❑ CEILING WIRE
❑
❑
❑
DSA/OSHPD/PROJECT: AVAILABLE: SOIL REPORT Y ❑ N ❑ SPECS: Y ❑ N ❑
APPROVED DOCUMENTS: APPROVED PLANS YIN N ❑ APPROVED SHOP DRAWING Y-2� N ❑
MATERIALS USED BY NT CTOR (INC UDE RESEARCH EPOR NO.O MATE IAL TEST EPORTS):
01: G
vlo
Verified by:
CONTRACTORS EOUIPMENT I MANPOWER USED:
AREA,,G ID LINES, PI ES INS ECTED:
4
- ®�r i d
�-c �O'A AI
a ilk
F
' f C�'Otr o'aW
WA d y J5q ay6
erecVi o vIL
o T xg 15i5
,
STRUC URAL NOTES, DETAIL, Oft RFIS U D: ,C
�atV6.
REMAR , INCLUDING MEETINGS:
_
w
`
a 14
dr a uj s
d
e —
PS —
d i 'e'
REWORK AS PERCENT OF ALL WORK TODAY:
PERCENT PROJECT COMPLETE:
THE WORK WAS ❑ WAS NOT ❑
Inspected in accordance with the requirements of the DSA/OSHPD/PROJECT
approved documents.
MATERIAL SAMPLING WAS❑ WAS NOT❑ N/A❑
Performed in accordance with DSA/OSHPD/PROJECT approved documents.
cc Project Architect Contractor ,
Structural Engineer Building Department •�
DSA Regional Office Owner '
School District
THE WORK INSPECTED
MET ❑ DID NOT MEET ❑
THE requirements of the
OSHPD/PROJECT approved documents.
Samples taken:
ZA
Weather: C1 ea rTemp:
%05
Signature of Special Inspector
Li .
Print Name
Certification #:
Verified by:
MTG�
Corporate:
2992 E. La Palma Ave. , Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
REPORT REQUIREMENTS: ICBO FIELD INSPECTION MANUAL/MTGL SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT.
MATERIALS USED BY CONTRACTOR INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
138 cubic yards of 4500 psi concrete from Robertson ready mix, design # 62121A
FIELD
Branch:
TYPE OF WORK
7313 Carroll Road, Suite G
AREA, GRID LINES, PIECES OBSERVED:
San Diego CA. 92121
Tel: 858.537.3999
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
Fax 858.537.3990
REPORT REQUIREMENTS: ICBO FIELD INSPECTION MANUAL/MTGL SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT.
MATERIALS USED BY CONTRACTOR INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
138 cubic yards of 4500 psi concrete from Robertson ready mix, design # 62121A
FIELD
REPORT
TYPE OF WORK
AREA, GRID LINES, PIECES OBSERVED:
AVAILABLE REPORTS PLANS SPECS SOILS SHOPS
REINFORCED CONCRETE
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
APPROVED Y N Y Y Y Y
ARCHITECT
Verified reinforcing steel for type, size, grade, splice lap, spacing & clearance for slab on grade, also monitored placement & consolidation of 138
Cubic yards of 4500 -psi concrete for slab on grade
FOR WEEK ENDING
Note: slab reinforcement was raised on adobe's and pulled up to mid-section of slab during placement
SGPA
# 2 from ticket # 5654223, slum 3 ''/2", concrete tem 78°, location @ s.o. ., approximately 800 sq. ft between lines C — D & 3 - 4
10/20/07
PROJECT No. 2145A02
ENGWNER
TEST REQUIRED: Slump, temperature, Pc
PLAN FILE NO.
MALEK
CONTRACTOR
PERMIT NO.
THE BERGMAN COMPANY
07-823
SUB -CONTRACTOR
PROJECT NAME
TIDWELL
KOMAR DESERT CENTER
INSPECTION ADDRESS
ADDRESS OF PROJECT
BLDG "E"
79-785 HWY 111 LA QUINTA
REPORT REQUIREMENTS: ICBO FIELD INSPECTION MANUAL/MTGL SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT.
MATERIALS USED BY CONTRACTOR INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
138 cubic yards of 4500 psi concrete from Robertson ready mix, design # 62121A
A-615 60 grade reinforcing steel
CONTRACTOR E UIPTMENT / MAN POWER USED:
Laser screed, 39 meter boom pump, concrete tools, mechanical vibrator, i I men
AREA, GRID LINES, PIECES OBSERVED:
Concrete placement — for 4" slab on grade from lines 1 to 5 & A to F
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
Concrete & masonry notes & details on sheets S1, S2, S3, SD. 1, SD.2, SD.3, SDA
REMARKS, INCLUDING MEETINGS:
Verified reinforcing steel for type, size, grade, splice lap, spacing & clearance for slab on grade, also monitored placement & consolidation of 138
Cubic yards of 4500 -psi concrete for slab on grade
Note: Verified slab thickness to be 4" thick throughout pad with laser prior to placement @ 4' square intervals
Note: slab reinforcement was raised on adobe's and pulled up to mid-section of slab during placement
Samples - # 1, from ticket # 5672273, slum 4", concrete tem 71', locations @ s.o. . approximately 800 sq'. ft between lines A — C & 1 —2
# 2 from ticket # 5654223, slum 3 ''/2", concrete tem 78°, location @ s.o. ., approximately 800 sq. ft between lines C — D & 3 - 4
WEATHER: Partly cloudy
SAMPLES TAKEN: 2 sets of 4 concrete
TEMPERATURE: 60's — 70's
TEST REQUIRED: Slump, temperature, Pc
SITE TIME START: 6:00 AM SITE TIME FINISH: 11:00 AM
LUNCH PREIOD: TRAVEL TIME: VERIFIED BY:
I DO CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT THIS WORK COMPLIES WITH THE SOILS
INVESTIGATION RECOMMEND TIONS AND / OR THE APPROVED PLANS, SPECS, AND APPLICABLE SECTION OF THE BUILDING CODES, UNO
SIGNATURE: FRI: 10 / 19 / 2007 ICBG Certification Number: 1037223-84, 88
Date of Report
PRINT NAME: DONALD SMITH City / county Certification number:
FMITGL
Corporate:
2992 E. La P ma Ave. , Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
Branch:
7313 Carroll Road, Suite G
San Diego CA. 92121
Tel: 858.537.3999
Fax 858.537.3990
R r.rvik I t(cyU 1 rc r.1v1cIN 1 a. 11,13v r 1cLv LV Jrcl. l r V IN 1VIA1N Lr
UA1V1 I UL J V l L 1V1A1N UAL Kt V Lt W PKh V lUU S Kt FL)K 1 _S ANL) LIS I S. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
STIRMIT A COPY WITH YOI IR WF.FK'S RFPORT
MATERIALS USED BY CONTRACTOR INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
FIELD
REPORT
TYPE OF WORK
Concrete tools, mechanical vibrator, 11. men
AVAILABLE REPORTS PLANS SPECS SOILS SHOPS
AREA GRID LINES, PIECES OBSERVED:
REINFORCED CONCRETE
APPROVED Y N Y Y Y Y
ARCHITECT
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
FOR WEEK ENDING
REMARKS, INCLUDING MEETINGS:
Verified anchor bolts, holdowns, & reinforcing steel for type, size, grade, splice lap, spacing & clearance for building footing's, also monitored
SGPA
10/13/07
1 PROJECT NO. 2145A02
ENGINNER
Sample - from ticket # 5653891, slum 4", concrete temperature 72°, locations line C -between 1 to 3 & spread footing D/3
PLAN FILE NO.
WEATHER: Partly cloudy
MALEK
TEMPERATURE: 60's — 70's
CONTRACTOR
PERMIT NO.
THE BERGMAN COMPANY.
07-823
SUB -CONTRACTOR
PROJECT NAME
TIDWELL
KOMAR DESERT CENTER
INSPECTION ADDRESS
ADDRESS OF PROJECT
BLDG "E"
79-785 HWY 111 LA QUINTA
R r.rvik I t(cyU 1 rc r.1v1cIN 1 a. 11,13v r 1cLv LV Jrcl. l r V IN 1VIA1N Lr
UA1V1 I UL J V l L 1V1A1N UAL Kt V Lt W PKh V lUU S Kt FL)K 1 _S ANL) LIS I S. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
STIRMIT A COPY WITH YOI IR WF.FK'S RFPORT
MATERIALS USED BY CONTRACTOR INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
70 cubic yards of 3000 psi concrete from Robertson ready mix, design # 1085A
A-615 60 grade reinforcing steel
CONTRACTOR E UIPTMENT / MAN POWER USED:
Concrete tools, mechanical vibrator, 11. men
AREA GRID LINES, PIECES OBSERVED:
Concrete placement — for perimeter building footing's, spread / column footing's & trash enclosure footing's from lines 1 to 5 & A to F, line C - 1 to 3
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
Concrete & masonry notes & details on sheets S1, S2, S3, SD. 1, SD.2, SD.3, SDA
REMARKS, INCLUDING MEETINGS:
Verified anchor bolts, holdowns, & reinforcing steel for type, size, grade, splice lap, spacing & clearance for building footing's, also monitored
placement & consolidation of 70 cubic yards of 3000 -psi concrete building perimeter & interior footing's
Note: contractor responsible for lay -out / dimensions of anchor bolts & holdowns
Sample - from ticket # 5653891, slum 4", concrete temperature 72°, locations line C -between 1 to 3 & spread footing D/3
WEATHER: Partly cloudy
SAMPLES TAKEN: 1 set of 4 concrete
TEMPERATURE: 60's — 70's
TEST REQUIRED: Slump, temperature, Pc
SITE TIME START: 7:00 AM SITE TIME FINISH: 12:00 PM
LUNCH PREIOD: TRAVEL TIME: VERIFIED BY:
I DO CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT THIS WORK COMPLIES WITH THE SOILS
INVESTIGATIO COMMENDATI NS AND / OR THE APPROVED PLANS, SPECS, AND APPLICABLE SECTION OF THE BUILDING CODES, UNO
SIGNATURE: FRI: 10 / 12 / 2007 ICBO Certification Number: 1037223-84, 88
Date of Report
PRINT NAME: DONALD SMITH City / county Certification number:
F--IMTGL
Corporate:
2992 E. La Palma Ave., Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
FIELD REPORT
Branch:
7313 Carroll Road, Suite G
San Diego CA. 92121
Tel: 858.537.3999
Fax 858.537.3990
TYPE OF WORK
138 cubic yards of 4500 psi concrete from Robertson ready mix, design # 62121A
AVAILABLE REPORTS
PLANS SPECS SOILS SHOPS
Laser screed, 39 meter boom pump, concrete tools, mechanical vibrator, 11 men
REINFORCED CONCRETE ,
APPROVED Y N
Y Y Y Y
ARCHITECT
FOR WEEK ENDING
Concrete & masonry notes & details on sheets S1, S2, S3, SD. 1, SD.2, SD.3, SDA
REMARKS, INCLUDING MEETINGS:
Verified reinforcing steel for type, size, grade, splice lap, spacing & clearance for slab on grade, also monitored placement & consolidation of 138
SGPA
Note: Verified slab thickness to be 4" thick throughout pad with laser prior to placement @ 4' square intervals
10/20/07
1 PROJECT NO. 21 0
ENGINNER
# 2 from ticket # 5654223, slump P, 3 %", concrete tem 78°, location s.o.., approximately 800 sq. ft between lines C — D & 3 - 4
PLAN FILE NO.
SAMPLES TAKEN: 2 sets of 4 concrete
TEMPERATURE: 60's — 70's
MALEK
CONTRACTOR
PERMIT NO.
THE BERGMAN COMPANY
07-823
SUB -CONTRACTOR
PROJECT NAME
TIDWELL
KOMAR DESERT CENTER
INSPECTION ADDRESS
ADDRESS OF PROJECT
BLDG "E"
79-785 HWY 111 LA QUINTA
KEFORI REQUMEMENTS: 1CB0 FIELD INSPECTION MANUAL/MTGL SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT.
MATERIALS USED BY CONTRACTOR(INCLUDING RESEARCH REPORTS NO. OR.MATERIAL TEST REPORTS):
138 cubic yards of 4500 psi concrete from Robertson ready mix, design # 62121A
A-615 60 grade reinforcing steel
CONTRACTOR E UIPTMENT / MAN POWER USED:
Laser screed, 39 meter boom pump, concrete tools, mechanical vibrator, 11 men
AREA, GRID LINES, PIECES OBSERVED:
Concrete placement — for 4" slab on grade from lines 1 to 5 & A to F
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
Concrete & masonry notes & details on sheets S1, S2, S3, SD. 1, SD.2, SD.3, SDA
REMARKS, INCLUDING MEETINGS:
Verified reinforcing steel for type, size, grade, splice lap, spacing & clearance for slab on grade, also monitored placement & consolidation of 138
Cubic yards of 4500 -psi concrete for slab on grade
Note: Verified slab thickness to be 4" thick throughout pad with laser prior to placement @ 4' square intervals
Note: slab reinforcement was raised on adobe's and pulled up to mid-section of slab during placement
Samples - # 1, from ticket # 5672273, slum 4", concrete tem 71°, locations s.o.. approximately 800 sq. ft between lines A — C & 1-2
# 2 from ticket # 5654223, slump P, 3 %", concrete tem 78°, location s.o.., approximately 800 sq. ft between lines C — D & 3 - 4
WEATHER: Partly cloudy
SAMPLES TAKEN: 2 sets of 4 concrete
TEMPERATURE: 60's — 70's
TEST REQUIRED: Slump, temperature, f
SITE TIME START: 6:00 AM SITE TIME FINISH: 11:00 AM
LUNCH PREIOD: TRAVEL TIME: VERIFIED BYc
I DO CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THA1'Ws ORK CO S WITH SOILS
INVESTIGATION RECOMMENDA NS AND / OR THE APPROVED PLANS, SPECS, AND APPLICABLE SECT B ING DES, UNO
SIGNATURE: FRI: 10 / 19 / 2007 ICBO Certification Number: 1037223-84, 88
Date of Report
PRINT NAME: DONALD SMITH City / county Certification number:
Corporate:
2992 E. La Palma Ave. , Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
FIELD REPORT
Branch:
7313 Carroll Road, Suite G
San Diego CA. 92121
Tel: 858.537.3999
Fax 858.537.3990
TYPE OF WORK
70 cubic yards of 3000 psi concrete from Robertson ready mix, design # 1085A
AVAILABLE REPORTS
PLANS SPECS
SOILS SHOPS
REINFORCED CONCRETE
APPROVED Y NY
Y
Y Y
ARCHITECT
Concrete & masonry notes & details on sheets S1, S2, S3, SD. 1, SD.2, SD.3, SDA
FOR WEEK ENDING
Verified anchor bolts, holdowns, & reinforcing steel for type, size, grade, splice IV, spacing & clearance for building footing's, also monitored
placement & consolidation of 70 cubic yards of 3000 -psi concrete building perimeter & interior footing's
Note: contractor responsible for lay -out / dimensions of anchor bolts & holdowns
SGPA
Sample - from ticket # 5653891, slum 4", concrete temperature 72°, locations @ line C — between 1 to 3 & spread footing D/3
10!13/07
PROJECT NO.
21440
ENGINNER
TEST REQUIRED: Slump, temperature, f c
PLAN FILE NO.
MALEK
CONTRACTOR
PERMIT NO.
THE BERGMAN COMPANY
07-823
SUB -CONTRACTOR
PROJECT NAME
TIDWELL
KOMAR DESERT CENTER
INSPECTION ADDRESS
ADDRESS OF PROJECT
BLDG "E"
79-785 HWY 111 LA QUINTA
REPORT REQUIREMENTS: ICBO FIELD INSPECTION MANUALMITGL SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS -OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT -
MATERIALS USED BY CONTRACTOR INCLUDING RESEARCH REPORTS No. OR MATERIAL TEST REPORTS):
70 cubic yards of 3000 psi concrete from Robertson ready mix, design # 1085A
A-615 60 grade reinforcing steel
CONTRACTOR E UIPTMENT / MAN POWER USED:
Concrete tools, mechanical vibrator, I 1 men
AREA, GRID LINES, PIECES OBSERVED:
Concrete placement — for perimeter building footing's, spread / column footing's & trash enclosure footing's from lines 1 to 5 & A to F, line C - 1 to 3
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
Concrete & masonry notes & details on sheets S1, S2, S3, SD. 1, SD.2, SD.3, SDA
REMARKS, INCLUDING MEETINGS:
Verified anchor bolts, holdowns, & reinforcing steel for type, size, grade, splice IV, spacing & clearance for building footing's, also monitored
placement & consolidation of 70 cubic yards of 3000 -psi concrete building perimeter & interior footing's
Note: contractor responsible for lay -out / dimensions of anchor bolts & holdowns
Sample - from ticket # 5653891, slum 4", concrete temperature 72°, locations @ line C — between 1 to 3 & spread footing D/3
WEATHER: Partly cloudy
SAMPLES TAKEN: 1 set of 4 concrete
TEMPERATURE: 60's — 70's
TEST REQUIRED: Slump, temperature, f c
SITE TIME START: 7:00 AM
LUNCH PREIOD:
SITE TIME FINISH: 12:00 PM
TRAVEL TIME:
I DO CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT WO SOILS
INVESTIGATION RECOMIv11:NDATIONS AND / OR THE APPROVED PLANS, SPECS, AND APPLICABLE SECTIO BUING CODE UNO
SIGNATURE: Ptyt.+/`l1' _.�"- FRI: 10 / 12 / 2007 ICBO Certification Number. 1037223-84, 88
Date of Report
PRINT NAME: DONALD SMITH City / county Certification number:
CORPORRama
San Diego / Imperial Cole
2992 E. La Ave., Suite A
7313 Carroll Road, Suite G
Anaheim, CA 92806
San Diego, CA 92121
Tel: 714.6322999
Tel: 858.537.3999
Fax 714.6322974
Fax: 858.537.3990
FIELD REPORT
Inland Empire
14467 Meridian Bldg. 2A
Riverside, CA 92518
Tel: 951.653.4999
Fax: 951.653.4666
Type Of Work X INSPECTOR TECHNICIAN
SSW
AVAILABLE: SOIL REPORT (1) (N) SPECS. (`n
APPROVED PLANS (Y) (N) APPROVED -SHOP DRAWINGS (Y)
ARCHITECT: SGPA Archrmcwm and Planning
1545 Hotel Cirde S. Ste. 200 San Diego, CA 92106
FOR WEEK ENDING 1111712007
PROJECT NO. 2146E02
Building - E
ENGINEER: Malek Engineers, Inc.
8380 Mitimar Mall Ste. 225 San Diego, CA 92121
REPORT NO. 1 PG 1 OF 1
CONTRACTOR: The Bergman Compnies
4300 Edison Avenue Chino, CA 91710
PLAN FILE NO.
PERMIT NO. 07-823
SUB -CONTRACTOR: Law Steel
820 South Hathaway Bktg. B Banning, CA 92220
PROJECT NAME: Komar Desert Center
INSPECTION ADDRESS: 79-785 Highway 111
La Quinta, CA 92253
ADDRESS OF PROJECT: 79-785 Highway 111
La Quinta, CA 92253
REPORTING REQUIREMENTS: ICBG FIELD INSPECTION MANUAL I MTGL SOIL MANUAL -REVIEW PREVIOUS REPORTS AND LISTS
IF THERE IS ANG WORK AT THE END OF THE WORK DAY, OR MISSING MTRS, AND FIRS, ETC., FILL OUT AND ATTACH A DEFICIENCY REPORT
WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTORS, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEKS REPORTS.
MATERIALS USED BY CONTRACTOR: (INCLUDE RESEARCH REPORT NO. OR MATERIAL TEST REPORTS):
WELDING ELECTRODES: (SMAW) E-7018
WELDERS: Jason Law
CONTRACTORS EQUIPMENT I MANPOWER USED:
WELDING MACHINE: Miller Trailblazer 301 G
AREA, GRIDLINES, PIECES OBSERVED:
Completed welding of the metal joist hanger at line 3/13.2 on the roof level.
STRUCTURAL NOTES, DETAIL, OR RFIS USED: (PER APPROVED PLANS)
REMARKS: INCLUDING MEETINGS:
REWORK AS PERCENT OF ALL WORK TODAY: PERCENT PROJECT COMPLETION:
WEATHER: HOT SAMPLES TAKEN:
TEMPERATURE: 86 Deg. F TESTS REQUIRED:
SITE TIME START: 1100 AM SITE TIME FINISH: 12:00 PM
LUNCH PERIOD: none TRAVEL TIME: VMFIED BY
100 BY CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT THIS WORK COMPUES WITH
THE SOIL INVESTIGATION RECOMMENDATIONS, AND / OR THE APPROVED PLANS, SPECIFICATIONS AND APPLICABLE SECTION OF THE
BUILDING CODE, UNLESS OTHERWISE NOTED IN THE DEFICIENCY REPORT.
r Sire
Steve W. Bodnar 11/13/2007
Prir►Ir Name
Date Of Report
084926485
ICBG Certification Number
City of La Quinta
City I County Cerdfrcation Number
Corporate:
2992 E. La Palma Ave. , Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
FIELD REPORT
Branch:
7313 Carroll Road, Suite G
San Diego CA. 92121
Tel: 858.537.3999
Fax 858.537.3990
TYPE OF WORK
REINFORCED CONCRETE
AVAILABLE REPORTS
APPROVED ( Y ) (N)
PLANS SPECS SOILS
(Y) (Y) (Y)
SHOPS
. Y )
ARCHITECT
SGPA
FOR WEEK ENDING
10/20/07 PROJECT NO. 21
0
ENGR
MALEK
PLAN FILE NO.
CONTRACTOR
THE BERGMAN COMPANY
PERMIT NO.
07-823
SUB -CONTRACTOR
TIDWELL
PROJECT NAME
KOMAR DESERT CENTER
INSPECTION ADDRESS
BLDG "E"
ADDRESS OF PROJECT
79 — 785 HWY 111 LA QUINTA
cc e rvx I RFQUIREMEhITS. ICBO FIELD INSPECTION MANUAIJMTGL SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT.
MATERIALS USED BY CONTRACTOR (INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
138 cubic yards of 4500psi concrete from Robertson ready mix, design # 62121A
A-615 60 grade reinforcing steel
CONTRACTOR EQUIPTNIENT / MAN POWER USED:
Laser screed, 39 meter boom pump, concrete tools, mechanical vibrator, 11 men
AREA, GRID LINES, PIECES OBSERVED:
Concrete placement — for 4" slab on grade from lines 1 to 5 & A to F
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
1
Concrete & masonry notes & details on sheets Si, S2, S3. SD.1, SD.2, SD.3, SD.4
REMARKS, INCLUDING MEETINGS:
Verified reinforcing steel for type, size, grade, splice 1p, spacing & clearance for slab on grade, also monitored placement & consolidation of 138
Cubicyards of 4500-psi concrete for slab on grade
Note: Verified slab thickness to be 4" thick throughout pad with laser prior to placement (4 4' square intervals
Note: slab reinforcement was raised on adobe's and pulled up to mid -section of slab during placement
Samples - # 1, from ticket # 5672273, slump @ 4", concrete temp @ 71°, locations @ s.o.g. approximately 800 sq. ft between lines A — C & 1-2
# 2 from ticket # 5654223, slump @ 3 1/2", concrete temp @ 78°, location @ s.o.g., approximately 800 sq. ft between lines C — D & 3 - 4
WEATHER: Partly cloudy
SAMPLES TAKEN: 2 sets of 4 concrete
TEMPERATURE: 60's — 70's
TEST REQUIRED: Slump, temperature, fc
SITE TIME START: 6:00 AM
LUNCH PREIOD:
SITE TIME FINISH:
TRAVEL TIME:
11:00 AM
VERIFIED BYE
I DO CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT IIS ORK CO i!' r WITH HE SOILS
INVESTIGATION RECOMMENDA •NS AND / OR THE APPROVED PLANS, SPECS, AND APPLICABLE SECT - 'i B u I ING DES, UNO
SIGNATURE:
PRINT NAME: DONALD SMITH
FRI: 10 / 19 / 2007
Date of Report
ICBO Certification Number: I037223-84, 88
City / county Certification number:
Corporate:
2992 E. La Palma Ave. , Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
Branch:
7313 Carroll Road, Suite G
San Diego CA. 92121
Tel: 858.537.3999
Fax 858.537.3990
FIELD REPORT
TYPE OF WORK
REINFORCED CONCRETE
AVAILABLE REPORTS
APPROVED (Y) (N)
PLANS SPECS
c Y) (Y)
SOILS SHOPS
(Y.).,..."'" (Y)
ARCHITECT
SGPA
FOR WEEK ENDING/J
10/13/07
PROJECT NO.
2145�1�11y1
ENGINNER
MALEK
PLAN FILE NO.
IIII��
CONTRACTOR
THE BERGMAN COMPANY
PERMIT NO.
07-823
SUB -CONTRACTOR
TIDWELL
PROJECT NAME
KOMAR DESERT CENTER
INSPECTION ADDRESS
B
BLDG "E"
ADDRESS OF PROJECT
79 — 785 HWY 111 LA QUINTA
R 1'OIt l Rl QU1RI M) N'1'S: 1CBO FIELD INSPECTION MANUAIJMTGI. SOIL MANUAL REVIEW PREVIOUS REPORTS AND LISTS. IF
THERE IS NON -CONFORMING WORK AT THE END OF WORK DAY, OR MISSING MTRS. AND RFIS, ECT., FILL OUT AND ATTACH A DEFICIENCY
REPORT. WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTOR'S, IS CORRECTED, SO NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
SUBMIT A COPY WITH YOUR WEEK'S REPORT.
MATERIALS USED BY CONTRACTOR (INCLUDING RESEARCH REPORTS NO. OR MATERIAL TEST REPORTS):
70 cubic yards of 3000 psi concrete from Robertson ready mix, design # 1085A
A-615 60 grade reinforcing steel
CONTRACTOR EQUIPTMENT / MAN POWER USED:
Concrete tools, mechanical vibrator, 11 men
AREA. GRID LINES, PIECES OBSERVED:
Concrete placement — for perimeter building footing's, spread / column footing's & trash enclosure footing's from lines 1 to 5 & A to F, line C - 1 to 3
STRUCTURAL NOTES, DETAILS, OR RFIS USED:
Concrete & masonry notes & details on sheets Si, 52, 53, SD.1, SD.2, SD.3, SD.4
REMARKS, INCLUDING MEETINGS:
Verified anchor bolts, holdowns, & reinforcing steel for type, size, grade, splice lap, spacing & clearance for building footing's, also monitored
placement & consolidation of 70 cubic yards of 3000-psi concrete @ building perimeter & interior footing's
Note: contractor responsible for lay -out / dimensions of anchor bolts & holdowns
Sample - from ticket # 5653891, slump @ 4", concrete temperature @ 72°, locations (a; line C — between 1 to 3 & spread footing @ D/3
_
WEATHER: Partly cloudy
SAMPLES TAKEN: 1 set of 4 concrete
TEMPERATURE: 60's — 70's
TEST REQUIRED: Slump, temperature, f c �------
.
SITE TIME START: 7:00 AM
LUNCH PREIOD:
SITE TIME FINISH:
TRAVEL TIME:
12:00 PM
I DO CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT ORK " i SOILS
INVESTIGATION
RECOMMENDATIONS AND / OR THE APPROVED PLANS, SPECS, AND APPLICABLE SECT10 THE BU ING COD UNO
SIGNATURE: L� � 3� FRI: 10 / 12 / 2007 ICBO Certification Number: 1037223-84, 88
Date of Report
PRINT NAME: DONALD SMITH
City / county Certification number:
CORPORATE
2992 E. La Palma Ave., Suite A
Anaheim, CA 92806
Tel: 714.632.2999
Fax: 714.632.2974
San Diego / Imperial County
7313 Carroll Road, Suite G
San Diego, CA 92121
Tel: 858.537.3999
Fax: 858.537.3990
FIELD REPORT
Inland Empire
14467 Meridian Bldg. 2A
Riverside, CA 92518
Tel: 951.653.4999
Fax: 951.653.4666
Type Of Work X INSPECTOR TECHNICIAN
SSW
AVAILABLE: SOIL REPORT (Y) (N) SPECS. (Y)
APPROVED PLANS (Y) (N) APPROVED SHOP DRAWINGS (Y)
ARCHITECT: SGPA Architecture and Planning
1545 Hotel Circle S. Ste. 200 San Diego, CA 92108
FOR WEEK ENDING 11/17/2007
PROJECT NO. 2146E02
Building - E
ENGINEER: Malek Engineers, Inc.
8380 Mirimar Mall Ste. 225 San Diego, CA 92121
REPORT NO. 1 PG 1 OF 1
CONTRACTOR: The Bergman Compnies
4300 Edison Avenue Chino, CA 91710
PLAN FILE NO.
PERMIT NO. 07-823
SUB -CONTRACTOR: Law Steel
820 South Hathaway Bldg. B Banning, CA 92220
PROJECT NAME: Komar Desert Center
INSPECTION ADDRESS: 79-785 Highway 111
La Quints, CA 92253
ADDRESS OF PROJECT: 79-785 Highway 111
La Quints, CA 92253
REPORTING REQUIREMENTS: ICBO FIELD INSPECTION MANUAL! MTGL SOIL MANUAL
IF THERE IS NON -CONFORMING WORK AT THE END OF THE WORK DAY, OR MISSING
WHEN A DEFICIENCY, YOURS OR A PREVIOUS INSPECTORS, IS CORRECTED, SO
SUBMIT A COPY WITH YOUR WEEKS REPORTS.
-REVIEW PREVIOUS REPORTS AND LISTS
MTRS, AND RFIS, ETC., FILL OUT AND ATTACH A DEFICIENCY REPORT
NOTE ON THE ORIGINAL DEFICIENCY REPORT AND
MATERIALS USED BY CONTRACTOR: (INCLUDE RESEARCH REPORT NO. OR MATERIAL TEST REPORTS):
WELDING ELECTRODES: (SMAW) E-7018
WELDERS: Jason Law
CONTRACTORS EQUIPMENT / MANPOWER USED:
WELDING MACHINE: Miller Trailblazer 301 G
AREA, GRIDLINES, PIECES OBSERVED:
Completed welding of the metal joist hanger at line 3/D.2 on the roof level.
•
STRUCTURAL NOTES, DETAIL, OR RFIS USED: (PER APPROVED PLANS)
REMARKS: INCLUDING MEETINGS:
REWORK AS PERCENT OF ALL WORK TODAY: PERCENT PROJECT COMPLETION:
WEATHER: HOT SAMPLES TAKEN:
TEMPERATURE: 86 Deg_ F TESTS REQUIRED:
SITE TIME START: 11:00 AM SITE TIME FINISH: 12:00 PM
LUNCH PERIOD: none TRAVEL TIME:
V IFIED BY
1 DO BY CERTIFY THAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT THIS WORK COMPLIES WITH
THE SOIL INVESTIGATION RECOMMENDATIONS, AND / OR THE APPROVED PLANS, SPECIFICATIONS AND APPLICABLE SECTION OF THE
BUILDING CODE, UNLESS OTHERWISE NOTED IN THE DEFICIENCY REPORT.
Signature
Steve W. Bodnar
11/13/2007
0849264-85
ICBO Certification Number
City of La Quinta
Print Name
Date Of Report City / County Certification Number
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.42 X 66,039 S.F. or $27,736.38 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Bank of America - Clint Knox
Name on the check
By Dr. Doris Wilson
Superintendent
Check No. 417710296
Telephone
Funding Commercial
LJ v
Z.
Fee collected /exempted by Shar, n MC
$27,736.38
II rey Payment Recd $0.00 �
�.e
% -,Over/U�der'
Signature C r
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will se e t notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the wilding or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original- Building Department/Applicant Copy -Applicant/Receipt Copy - Accounting
-t • �i 22
�'�N_ ��i � 7 • d; 23
Bin #°
-M � .715' 'eity f La Quin to
Building 8r Safety Division .
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
-� Building Permit Application and Tracking Sheet
Permit #
14�roject
p t
Address: ?9 — 8 � 7 � 8r � %ItJY % l r
Owner's Name: KO MAR )NV 0TM Q4T$,
:A. P. Number: QQ —' ZQ "+ Q 3
Address: V3 6921WOM-M FLAZ',,A., :#?.+7
Legal Description: PARGIEL S 4 F 'P M - 3 9C160.1
Contractor:M GoMPAN 1 E5
Address: A' 3400 E!1715014 /AV GN UE
City, ST, Zip: pQ)�r
�f
Telephone: I l g —
Project Description: L -
City, ST, Zip: G 14 l N o GA C71-1/0
Telephone: 09 &Z7- 31051
E%
State Lic. # : 3 �p 8 City Lie. #..,105 (
Arch., Engr., Designer: S;4PA ,4Rr-N irrecroRE
LCArrAc ggp
Address: 16 45 MSL c IRel.6 $1
Fog logo P05A�4 a
City, ST, Zip: N GA g2/08
Telephone: 410 401
State Lic. #:1716 +
G
?>>z«::< v>t sm•»:r<•;»<;>:>:>.<°°:`•;<:<
Construction Type: � N Occupancy: M
Project type (circle one): New Add'nAlter Repair Demo
Ft.$- # Stories: I #Units: N . .
Name of Contact Person: NEIL iV l)<o NSq.
Telephone # of Contact Person: 1 2 / — 0 3
11
Estimated slue o Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Reed
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for orrectio
Plan Check Deposit
Truss Cales.
Called Contact Person,G,t i
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2d. Review, ready for correctio /issue 7!
Electrical
Subcontactor List
Called Contact PersonAWM
Q
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
�
n _
Total Permit Fees
• c -ti
tLllrk-1 �OyVuQ1e� �j�i�
a" Lq �06� �
►ZI m *W *W
A division of
Imperiallnigation Dishict
81-600 Avenue 58 • La Quinta, CA 92253 • www.iid.com
IlDPD-DDC May 15, 2007
Komar investments, LLC
Attn: Clint Knox
23 Corporate Plaza, Ste. 247
Newport Beach, CA 92660
Subject: Available Short Circuit Current Calculation for Komar Desert Center, for
Building E, 79-785 Hwy. 111, La Quinta, CA for a Service Voltage
120/208V, 3 Phase, 1200A Panels.
Dear Mr. Knox:
The available Short Circuit Current at the secondary terminals of the transformer is
47,255 •Amps.RMS Symmetrical at 208 volts.
This is based upon the following information:
1) Transformer size: 750 KVA
2) Transformer impedance: 4
3) Primary -voltage: 7,200/12,470Y volts
4) Secondary voltage: 208 volts
5) High -side KVA available: 185,000 KVA
6) Transformer connection: Wye/Wye
7) No motor contribution to fault current.
Please contact me should you have any questions, at (760) 398-5820.
Thank You,
'QFIQS
�F T. Pot gggpfi
CP/ms ,
5ECFAULT.Ltr.KamarDcscrtCenterBuildingE&F
n
%
t f.
SGPA ARCHITECTURE ■ PLANNING
PROPOSAL REQUEST #5
Komar Desert Center
Shop Buildings D, E & F
La Quinta, California .
SGPA Project No.: 20612-D-01 .
SAN DIEGO ■ SAN FRANCISCO
Novemberl3, 2007
This narrative is an attachment to the corresponding Proposal Request Form (AIA Document G709) with
the same date and project reference. The General Contractor is responsible for reviewing this narrative,
together with the referenced documents (drawings, specifications, etc.), and distributing the information
to each affected subcontractor.
Item No. 1
Lease Spaces D2 & D3 Revisions
Ref. Sheet
A)
Add grease waste line to space D2.
P2.1
B)
Delete grease waste line from space D3.
Item No. 2
Lease Space D4 -Starbucks Revisions
Ref. Sheets
A)
Revise size and type of drive -up window and provide stainless
A2.1, A2.3, A2.4, A6.1.1,
steel shelf at window.
A7.3, MO. 2, M2.1, M2.2,
B)
Provide 2 light fixtures at the drive -up window.
P2.1, E0.1, E0.2, E0.4.1,
C)
Delete the Telephone Backboard and provide conduit and pull
E0.4.2, E2.1 & E2.2
string only. (Relocate telephone stub.)
D)
Revise location of sign J -boxes and add one more sign J -box at
side and back. Dimensionally locate the sign J -boxes.
E)
Specify Honeywell thermostat.
F)
Revise grease interceptor vent from 2" to 3", with 3" VTR.
G)
Provide a 3" diameter sheet metal vent in the roof, for tenant
toilets.
H)
Provide 10" diameter sheet metal penetration in roof, for tenant
exhaust fan.
1)
Re -circuit 400 amp electrical panel for tenant HVAC and provide
(1) 200 amp' electrical panel fed from 400 amp electrical panel.
J)
Relocate Starbuck's "Thank You" Sign.
K)
Relocate address numerals.
Item No. 3
Lease Space E3 Revision
Ref. Sheet
A)
Add grease interceptor to North exterior side of building and stub
P3.1
into space E3.
B)
Revise water line to 1-1/2".
1545 Hotel Circle South, Studio 200, San Diego, California 92108 David Reinker, AIA . President 619.297.0131 (p) 619.294.9534 (f) www.sgpo.com
Y `
Proposal Request #5
Mmar Desert Center
November 13, 2007
Page 2of3
Item No. 4
Lease Spaces F1 /F2 — La Salsa Revisions
Ref. Sheets
A)
'Delete (2) 200 amp electrical panels and provide (1) 400 amp
AS1.1, A0.3, A4.1, A4.2,
electrical panel.
A4.3, A4.4, A4.5, A6.9,
B)
Delete demising wall between spaces F1 and F2.
A7.1, A7.2, M4.1, M4.2, P0.2
C)
Delete toilet rooms.
P4.1, E0.2, E0.3, E4.1 & E4.2
D)
Revise space F2 storefront entrydoor F4, from double doors to
single door. Add storefront Type 13.
E)
Delete suspended ceiling.
F)
Delete HVAC distribution.
G).
Delete light fixtures.
H)
Delete rear door #F9. Provide for future installation.
1)
• Revise space F1 water line to 1-1/2".
Item No. 5 Lease Spaces F4/F51evisions
Ref. Sheets A) Delete demising wall between spaces F4 and F5.
AS. 1.1, A0.3, A4.1, A4.2, B) Delete toilet rooms
A4.3, A4.4, A4.5, A6.9, C) Delete suspended ceiling.
A7.1, A7.2, M4.1, M4.2, P0.2, D) Delete light fixtures.
P4.1, E0.2, E4.1 & E4.2 E) Delete drywall.
F) Delete electrical outlets.
G) Relocate electric panel F5.
H) Delete HVAC distribution
1) Delete rear door #F19. Provide for future installation.
J) Revise space F4 storefront entry door F2, from double doors to
single door. Add storefront Type 13.
Item No. 6 Canopy Column
Ref. Sheet A) Clarify canopy column construction, per Details 27 & 28. .
A8.4 B) Clarify pre -cast concrete cap, per Detail 29.
C) Clarify light fixture connection, per Detail 30.
D) Clarify base construction, per Detail 20.
Item No. 7 Miscellaneous Details
Ref. Sheets A) Add angle to Detail 17/A8.3.
A8.3, A8.4 & A8.6 B) Clarify number of bolts at Detail 24/A8.4.
C) Add Seismic Joint Detail 16/A8.6.
Proposal Request #5
• 'f'omar Desert Center
"''November 13, 2007
Page 3of3
f
Item No. 8
RTU electrical Revisions
Ref. Sheets
A) Revise circuiting for,electrical outlets and smoke detectors from
E2.3 & E4.3
house panel to lease space panel, at all RTU's (all buildings).
(Sheets E3.3 & E5.3 not
included)
Item No. 9
Title — 24 Forms
Ref. Sheets
A) Added 3 new sheets to update Title 24 information for buildings
TS -1, E0.8, E0.9 & E0.10
D, E & F.
F:\2006\20612 -1g 111 \D-01 \Ca\Pr's\No5Attch.doc
John R. Hawkins
Fire Chief
Proudly serving the
Unincorporated
Areas of Riverside
County and the
Cities of -
Banning
Beaumont
4.
Calimesa
.
Canyon Lake
.;.
Coachella
Desert Hot Springs
Indian Wells
4.
Indio
Lake Elsinore
La Quinta
4.
Moreno Valley
Palm Desert
.•
Perris
4.
Rancho Mirage
ev
San Jacinto
Temecula
Board of Supervisors
Bob Buster,
District I
John Tavaglione,
District 2
Jim Venable,
.District 3
Roy Wilson,
District 4
Marion Ashley,
District 5
RIVERSIDE COUNTY FIRE DEPARTMENT
' In cooperation with the
` California Department of Forestry and Fire Protection
210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910
June 5, 2007
Neil Dixon
SGPA Planning & Architecture
1545 Hotel Circle Suite 200
San Diego, Ca. 92108
Re: Building Plan Review
Komar Desert Center 79-825 Highway 111 Buildings B, C, D. E, F, H
Fire Department personnel have reviewed and approved the plans you submitted for the above
referenced project. Please be advised the following conditions apply as a part of the conditions for
the issuance of a building permit.
J
1) These conditions are for a shell building and will receive a shell final only. No fire and life safety
clearance will be issued for a tenant space until the specific occupancy classification has been
established and tenant improvement plans have been'reviewed and conditioned by the Riverside
County Fire Department.
2) Fire Department approval is based upon the 2001 CBC requirements for Group B occupancies. It
is prohibited to use, process or store any materials in the occupancy that would classify it as a
Group H occupancy per Sec. 307 of the 2001 CBC.
3) Repair work and/or maintenance using open flame equipment, welding or the use of Class I, II,
or III -A liquids are prohibited.
4) A combination of on-site and off-site Super wet barrel fire hydrants (6" x 4" x 21/2" x 21/2'), on a
looped system shall be located not less than 25' or more than 165' from any portion of the
buildings as measured along approved vehicular travel ways. The required fire flow shall be
available from any adjacent hydrants in the system.
The following conditions must be met prior to occupant.
t
5) Fire sprinkler system plans for the tenant improvement area must be submitted to the Fire
Department for review, along with a plan/inspection fee. A licensed C-16 contractor will have to
Submit plans for review and approval and modify the fire sprinkler system in accordance with
NFPA 13, 1999 Edition. A licensed C-16 contractor shall do all sprinkler work and certification.
The approved plans, with Fire Department Job card must be at the job site for all inspections.
6) As may be necessary to maintain proper fire sprinkler protection due to constructions changes,
fire sprinkler system plans for the tenant improvement area may be required to be submitted to
the Fire Department for review, along with a plan/inspection fee. The sprinkler system will have
to be modified and designed in accordance with NFPA 13, 1999 Edition. A licensed C-16
EMERGENCY SERVICES DIVISION • PLANNING SECTION . INDIO OFFICE
82-675 Highway 111, 2n° FI., Indio, CA 92201 . (760) 863-8886 • Fax (760) 863-7072
contractor shall do all sprinkler work and certification. The approved plans, with Fire Department Job card must be at
the job site for all inspections.
7) Whenever sprinkler overhead mains of 4" size or larger are provided, the Riverside County Fire Department requires
documentation from a structural engineer that the roof structural members will be capable of supporting the weight of
the water filled mains and attached lines. Provide appropriate detailed documentation, with a wet stamp and
signature, by the project structural engineer.
I
Buildings/facilities
8) Provide either a separate Knox Key Lock box, Model 4400, 3200 or 1300, mounted per recommended standard of the
Knox Company or provide key(s) for inclusion in the general building Knox Box. If the building/facility is protected with
a fire alarm system or burglar alarm system, the lock boxes will require "tamper" monitoring. Special forms are
available from this office for the ordering of the Knox Box. This form must be authorized and signed by this office for
the correctly coded system to be purchased.
9) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible
tags affixed for identification of the correlating tenant space.
10) If the building/facility is protected with a fire alarm_ system or burglar alarm system, the lock boxes will require
"tamper" monitoring.
11) If the facility requires Hazardous Materials Reporting (Material Safety Data sheets) the Knox Haz Mat Data and Key
Storage Cabinet, Model 1220 or 1300 with tamper switches shall be used. If the building/facility is protected with a fire
alarm system or burglar alarm system, the lock box will require "tamper" monitoring.
Other reouirements:
12) Directory display boards will be required adjacent to each roadway access to the development. These shall be an
illuminated diagrammatic representation of the actual layout that shows the name of complex, all streets, building
designators, unit numbers and fire hydrant locations within the complex. These directories shall be a minimum of 4' x
4' in dimension. Addressing of buildings and units shall conform to the Riverside County Addressing Policy. Additional
information and details may be obtained by contacting the Fire Department Planning staff.
13) Install panic hardware and exit signs as per Chapter 10 of the 2001 CBC.
14) All egress doors shall comply with CBC Sec. 1003.3.1.8 for proper door hardware and as noted on Sht. of the
building plans. '
I
15) Prior to final inspection of any building, the applicant shall prepare and submit to the Fire Department for approval, a
site plan designating required fire lanes with appropriate lane painting and/or signs.
16) Certain designated areas will be required to be maintained as fire lanes.
17) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. Contact a certified extinguisher
company for proper placement and spacing of equipment.
18) If the building is used for high piled/rack storage, the building construction and fire sprinkler system must meet 1999
NFPA 13 and Article 81 of the 2001 CFC.
EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE
82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072
19) Shelving, counters, etc:, must be in place, however, no merchandise may be placed in the building prior to inspection.
20) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear
access if applicable. Building address numbers shall be a minimum of 12" for building(s) up to 25' in height, and 24" in
height for building(s) exceeding 25' in height. In multi -tenant buildings, businesses shall post the business name and
suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All
addressing must be legible and of a contrasting color with the background and adequately illuminated to be visible from
the street at all hours. , -
21) Electrical room door shall be posted "ELECTRICAL ROOM" on the outside of door.
22) Room capacity shall be posted in a conspicuous place on an approved sign near the main exit from the room.
23) A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front
exit doors. The sign shall be in letters not less than one inch high on a contrasting background.
I '
Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy.
i
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections
Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886.
All questions regarding the' meaning of these conditions should be referred to the Fire Department Planning & Engineering
staff at (760) 863-8886.
Sincerely, i
Tracy Hobday
Chief Fire Department Planner
By- i
/Bb
Sonia Cooley rich
Fire Safety Specialist ; ms Inspector
4 EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE
1 82-675 Highway 111, 2nd A., Indio, CA 92201 9 (760) 863-8886 • Fax (760) 863-7072
30mDA Y TEMPORARY
Certificate of Occupancy
EXPIRES JUNE 09, 2008
Taf ^FlwR"
Building & Safety Department
This Temporary Certificate, issued pursuant to the requirements of Section 109 of the California
Building Code, and with the concurrence of the Public Works Department and Community
Development Department, certifies that the SHELL BUILDING, at the time of issuance, was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 79-785 HIGHWAY III (BUILDING "El
Use classification: COMMERICAL
Occupancy Group: B & M
Owner of Building: KOMAR INV
'tit ��
Building Official
Type of Construction: TYPE V-N
POST IN A CONSPICUOUS
Building Permit No.: 07-823
Land Use Zone: CR
Address: 23 CORPORATE PLZ STE 247
City, ST, ZIP: NEWPORT BEACH, CA 92660
By: STEVE TRAXEL
Date: MAY 09, 2008