BCOM2015-000478-495 CA LA QUINT ApplicatLdn Number: Property Address: APN: Application Description Property Zoning: Application Valuation: I VOICE (760) 777-7125 192253 FAX (760) 777-7011 . COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 1/30/2015 BCOM2015-0004 Owner: 79785,HIGHWAY 111 #102 P6K PORTFOLIO KDP - 600440006 2301 ROSECRANS STE 21 KOMAR DESERT CENTER - T.I. FIT GALS CLOSET EL SEGUNDO, CA 92253 a U $20,000.00 Applicant: SOUTH WEST CONCEPTS -ARCHITECT 78115 CALLE ESTADO 201 . LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: AEC285 /� Contract __Wl/% I� �SC�.�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:. () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wjprk for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply wit those provisions. Dater rJ Applicant: WARNING: AILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application., the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state.that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: �� ignature(Applicant orAgent):•/ 0 on z Contractor: CAD MATT KLEINE CONTRAC . 73950 22ND AVENUE o n cNj SKY VALLEY, CA 92241 cin (760)578-2038 Llc. No.: AEC285 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wjprk for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply wit those provisions. Dater rJ Applicant: WARNING: AILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application., the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state.that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: �� ignature(Applicant orAgent):•/ T BUILDING ENERGY ANALYSIS REPORT PROJECT: Fit Gals Closet Tenant Improvement 79-785 Highway 111, Suite 102 La Quinta, Ca 92253 Project Designer: South West Concepts, Inc 78-145 Calle Estado, Suite 21.5 La Quinta, CA 92253 (760) 564-4707 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY SEPT. APPROVED FOR NSTRU N' 6A � bsey fowl Lo/5 —&00+ RECEIVED Job Number: JAN 13 2015 CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 1/8/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California. Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 6.4 by Ener Sok User Number: 6712 gyp; r a - TABLE OF CONTENTS r ' Cover Page 1 Table of Contents 2 Form LTI-01-E Indoor Lighting 3 Form LTI=02-E Lighting Controls g Form LTI-03-E Indoor Lighting Power Allowance 12 EnergyPro 6.4 by EnergySoft Job Number: ID: User Number: 6712 STATE OF CALIFORNIA INDOOR LIGHTING CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 1 of. 5) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 Climate Zone: 15 Conditioned Floor Area: 2,960 YES NO FORM TITLE YES NRCC-LIT-01-E Certificate of. Compliance. All Pages required on plans for all submittals. Unconditioned Floor Area : 0 Lighting Controls, Certificate of. Compliance, and PAF Calculation. All Pages required on plans for all submittals. General Information Indoor Lighting Power Allowance NO I NRCC-LIT-04-E Tailored Method Worksheets NO I NRCC-LIT-05-E Line Voltage Track Lighting Worksheets Building Type: ❑ Schools E3 Nonresidential ❑ Relocatable Public Schools ❑ El High -Rise Residential Conditioned Spaces ❑ ❑ Hotel/Motel Unconditioned Spaces Phase of Construction: ❑ New Construction ❑ Addition ❑ Alteration Method of Compliance: ❑ Complete Building 0 Area Category ❑ Tailored LIGHTING COMPLIANCE DOCUMENTS (select yes for each document included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission. YES NO FORM TITLE YES NRCC-LIT-01-E Certificate of. Compliance. All Pages required on plans for all submittals. YES NRCC-LIT-02-E Lighting Controls, Certificate of. Compliance, and PAF Calculation. All Pages required on plans for all submittals. YES NRCC-LIT-03-E Indoor Lighting Power Allowance NO I NRCC-LIT-04-E Tailored Method Worksheets NO I NRCC-LIT-05-E Line Voltage Track Lighting Worksheets Summary of Allowed Lighting Power Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Watts Watts Installed Lighting Installed Lighting 3,318 0 1. NRCC-LTI-01-E, page 4 + NRCC-LTI-01-E, page 4 + 2. PORTABLE ONLY FOR OFFICES + NRCC-LTI-01-E, page 3 3 Minus Lighting Control Credits 11 Minus Lighting Control Credits 0 NRCC-LTI-02-E, page 2 NRCC-LTI-02-E, page 2 4 Adjusted Installed Lighting Power = 3,307 Adjusted Installed Lighting Power = 0 (row 1 plus row 2 minus row 3) (row 1 minus row 3) CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS Indoor Lighting Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 N RCC-LTI-01-E (Page 2 of. 5) 5. Complies ONLY if Installed <_ Allowed Complies ONLY if Installed <_ Allowed NO 6. Allowed Lighting Power Conditioned NRCC-LTI-03-E, page 1 3,552 Allowed Lighting Power Unconditioned NRCC-LTI-03-E, page 1 0 Declaration of Required Installation Certificates — Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title V NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. NRCI-LTI-01-E - Must be submitted for all buildings ❑ Field Inspector NRCA-LTI-03-A - Must be submitted for automatic daylight controls. NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), ❑ Field Inspector NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls. to be recognized for compliance. NRCI-LTI-03-E - Must be submitted for a line -voltage track lighting integral current limiter, or for a supplementary ❑ Field Inspector overcurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. ./ NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a ❑ Field Inspector conference room, a multipurpose room, or a theater to be recognized for compliance. NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. ❑ Field Inspector NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for ❑ Field Inspector compliance. Declaration of Required Certificates of Acceptance — Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. ❑ Field Inspector NRCA-LTI-03-A - Must be submitted for automatic daylight controls. ❑ Field Inspector NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls. ❑ Field Inspector CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING CALIFORNIA ENERGY CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 3 of. 5) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: ® CONDITIONED SPACE ❑ UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and' FIELD INSPECTION ENERGY CHECKLIST ❑ The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems. ❑ When Complete Building Method is used for compliance, list each different type of luminaire on separate lines. ❑ When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines ❑ Also include track lighting in schedule, and submit the track lighting compliance form (NRCC-LTI-05-E) when line -voltage track lighting is installed. B. Installed Portable Luminaires in Offices — Exception to Section 140.6(a) ❑ This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance form. ❑ This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office ❑ Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. Office Portable Luminaire Office Installed Portable Luminaire Watts Per Square Office Location Field Schedule Foot Inspector A B C D E F G H I J Installed ,— Z portable 0 v, Watts If F5 0.3, Identify Office area in which 3 a- luminaire , ? a per enter zero; E x G these portable luminaires are v T, °/ o, Complete Luminaire Description O1' watts in this �m square installed — (i.e., LED, under cabinet, furniture mounted Watts per office n foot if F > 0.3, direct/indirect) Luminaire (B x C) (D / E) (F-0.3) ❑ ❑ ❑ ❑ ❑ D ❑ ❑ ❑ ❑ Enter sum total of all pages into NRCC- Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office: LTI-01-E; Page 1 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 4 of. 5) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: E3 CONDITIONED SPACE ❑ UNCONDITIONED SPACE C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Luminaire Schedule Installed Watts Location Field Inspector 1 A B C D E F G H How wattage was determined a H O o Complete Luminaire Description r 3 ('1 D+ o^ 0 0 C 3 z 3 s F (i.e, 3 lamp fluorescent troffer, ,'� a O W n Z E o w j' C m. (1 V, H x a ° Primary Function area in which z - F32T8, one dimmable electronic ballast) M m� = E 0 m - a these luminaires are installed Pass Fail 2X4 (3) 4 ft Fluorescent T8 90.0 ® ❑ 35 3,150 Retail Sales, Wholesale ❑ ❑ Can Lt. (1) 13w Compact FI 15.0 ® ❑ 4 60 Retail Sales, Wholesale ❑ ❑ CFL (1) 26w Compact Fluorescent 28.0 ® ❑ 1 28 Retail Sales, Wholesale ❑ ❑ Fan Lt. 17 W LED 20.0 ❑ ® 4 80 Retail Sales, Wholesale ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ INSTALLED WATTS PAGE TOTAL: 3,318 Enter sum total of all pages into NRCC-LTI-01-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA ; INDOOR LIGHTING CEC-NRCC-LTI-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 5 -of 5) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Documentation Author Signature: Company: Scott Design and Title 24, Inc, Signature Date: 1/8/2015 Address: 77085 Michigan Drive CEA/ HERS Certification Identification (if applicable): City/State/Zip: Palm Desert, CA 92211 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistentwith the ' formation provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with thi uilding permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building pe i (s) issued for the building, and made available to the enforcement'agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Co li nce is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Steve Nieto Responsible Designer Signa i Company: South West Concepts, Inc Date Signed: w Address: 78_145 Calle Estado, Suite 21.5 License: , City/State/zip: La Quinta, CA 92253 Phone: (760) 564-4707 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CERTIFICATE OF COMPLIANCE Indoor Lighting - Lighting Controls Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 The NRCC-LTI-02-E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project N RCC-LTI-02-E (Pagel of 31 Mandatory Lighting Control Declaration Statements (Indicate if the measure applies by checking yes or no below.) YES NO Control Requirements Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with Section 110.9. Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with Section 130.4(b). One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and §130.0. Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b). A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.0. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with Section 130.1. All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.1(a)4. The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the multi-level lighting control requirements in accordance with Section 130.1(b). All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c). �I Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in accordance with Section 130.1(e). Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF controls, and demand responsive controls. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING — LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 06114) CERTIFICATE OF COMPLIANCE Indoor Lighting - Lighting Controls Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: El CONDITIONED SPACES ❑ UNCONDITIONED SPACES COMMISSION N RCC-LTI-02-E (Page 2 of 3) MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST PAF Credit Calculation Z t n (D V, D (D a 1 r 7 G rY _ f) � rD (nD N Standards Complying With ° r. v v " x (D .' �• CD n Lighting Control Schedule (✓ all that apply, or enter 'E' if Exempted) a ° -n = a ° a m o A B C D E F G H I J K L M N O Type/ Description of Lighting Control (i.e.: occupancy sensor, # 'O' `O' `a' n °, O Location in Building automatic time switch, of o 0 0 0 o 0 N dimmer, automatic daylight, Units v v etc...) Tenant Improvement Occ Sensor - <= 125 sqft ✓ 28 0.40 11 ✓ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1 ❑ ❑ ❑ Control Credit PAGE TOTAL (Sum of Column M): 11 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF Control Credit for all pages HERE (Sum of all Column M): 11 Enter Control Credit total into NRCC-LTI-01-E; Page 1. 1. §130.1(a) =Manual area controls, §130.0(b) = Multi Level, §130.1(c) =Auto Shut -Off; §130.1(d) =Mandatory Daylight, • §130.1(e) =Demand Responsive; §140.6(d) = Additional lighting controls installed to earn a PAF, • §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out signed, and submitted. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING — LIGHTING CONTROLS 'EC -NRCC-LTI-02-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION '%� CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 3) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 r G A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: ❑ CONDITIONED SPACES 0 UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST PAF Credit Calculation z t n r7 n _T 1 0 r o n -0 Standards Complying With 0 `� v 3 x a �• m fD Lighting Control Schedule (✓ all that apply, or enter 'E' if Exempted) ro M a ° -n = �* n m - A B C D E F G H I I J K L M N O Type/ Description of Lighting Control (i.e.: occupancy sensor, # `4' L40n to o to p ` , Location in Building automatic time switch, of o 0 0 0 0 o d dimmer, automatic daylight, Units v etc...) ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ a ❑ Control Credit PAGE TOTAL (Sum of Column M): 0 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF Control Credit for all pages HERE (Sum of all Column M): 0 Enter Control Credit total into NRCC-LTI-01-E; Page 1. 1. §130.1(a) =Manual area controls, §130.0(b) = Multi Level; §130.1(c) =Auto Shut -Off,• §130.1(d) =Mandatory Daylight, §130.1(e) =Demand Responsive, §140.6(d) = Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check. Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out signed, and submitted. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTI-02-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 3 of 3) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 r DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Documentation Author Signature: , A e{y Company: Scott Design and Title 24, Inc, Signature Date: 1/8/2015 Address: 77085 Michigan Drive CEA/ HERS Certification Identification (if applicable): City/State/Zip: Palm Desert, CA 92211 phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Steve Nieto Responsible Designer Signature: Company: South West Concepts, Inc Date Signed: Address: 78_145 Calle Estado, Suite 21.5 License: city/state/zip: La Quinta, CA 92253 Phone: (760) 564-4707 i CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE ;EC-NRCC-LTI-03-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION `*� CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 1 of 4) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 ALLOWED LIGHTING POWER A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: 0 CONDITIONED spaces ❑ UNCONDITIONED spaces A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES ❑ If using Complete Building Method for compliance, use only the total in column (a) as total allowed building watts. ❑ If using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total allowed building watts (a) I I (b) 1. Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page) 2. Area Category Method Allowed Watts. Documented in section C-1 of. NRCC-LTI-03-E (below on this page) 3,552 3. Tailored Method Allowed Watts. Documented in section A of NRCC-LTI-04-E 0 TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 3,552 ❑ Check here if building contains both conditioned and unconditioned areas. B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE A B 3,552 C 0 D TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER (ft) X COMPLETE BLDG. AREA = ALLOWED WATTS Total Area: Total Watts. Enter Total Watts into section A, row 1 (Above on this page) C-1 AREA CATEGORY METHOD TOTAL LIGHTING POWER ALLOWANCES (C-2 plus C-3) Watts Total from section C-2 3,552 Total from section C-3 0 Total Watts. Enter Total Watts into section A, row 2 (Above on this page) 3,552 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance ' June 2014 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE r�',imi�s :EC-NRCC-LTI-03-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION '%Qi" CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 2 of 4) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: m CONDITIONED spaces 11 UNCONDITIONED spaces C -2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE ❑ Do not include portable lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC-LTI-01-E. ❑ Separately list lighting for each primary function area as defined in §100.1 of the Standards. A B C D AREA CATEGORY (From §140.6 Table 140.6-C) WATTS ALLOWED Location in Building Primary Function Area per Table 140.6-C PER (ft) X AREA (ft') = WATTS Tenant Improvement Retail Sales, Wholesale 1.20 2,960 3,552 TOTALS 12,960 Enter sum total Area Category allowed watts into section C-1 of NRCC-LTI-03-E (this compliance form) 3,552 WATTS CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 4 of 4) Project Name: Fit Gals Closet Tenant Improvement Date Prepared: 1/8/2015 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Documentation Author Signature: Company: Scott Design and Title 24, Inc, Signature Date: 1/8/2015 Address: 77085 Michigan Drive CEA/ HERS certification Identification (if applicable): City/State/zip: Palm Desert, CA 92211 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Steve Nieto Responsible Designer Signature: Company: South West Concepts, Inc Date Signed: Address: 78-145 Calle Estado, Suite 21.5 License: City/State/Zip: La Quinta, CA 92253 Phone: (760) 564-4707 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 DESCRIPTION PermitTRAK - + ••ITY PAID $474.03 ' ,,BCOM2015-0004Address:,79785 HIGHWAY 111 #102 ' Apn: 600440006 $474.03 BUILDING STANDARDS ADMINISTRATION BSA$1.00 . BSAS SB1473 FEE 101-0000-20306 0 $1.00 ELECTRICAL $48.34. DEVICES, FIRST 20 101-0000-42403 0 $24.17 DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 REMODEL ' •,, $419.09 REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $130.50 REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $104.40 REMODEL, FIRST 100 SF 101-0000-42400. 0 $49.31 REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 STRONG MOTION INSTRUMENTATION SMI - $5.60 SMI - COMMERCIAL TOTAL FEES PAID BY RECEIPT:R3534 101-0000-20308 0 $5.60 Date Paid: Thursday, January 29; 2015 Paid By: FIT GALS CLOSET Cashier: SKH Pay Method: CHECK 1001 Printed: Thursday, January 29, 2015 3:47 PM 1 of 1 GJ <ve rr ie c DESCRIPTION FINANCIAL INF•• L • ACCOUNT its CITY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 j 0 $1.00 $1.00 1/29/15 PAID,BY METHOD - RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK '' R3534 1001 SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE DEVICES, FIRST 20 101-0000-42403 0 $24.17 $24.17 1/29/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH DESCRIPTION ACCOUNT ; CITY AMOUNT PAID PAID DATE DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 1/29/15 PAID BY METHOD RECEIPT # CHECK .# CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH Total Paid for ELECTRICAL: $48.34 $48.34 DESCRIPTION ACCOUNT, CITY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $130.50 $130.50 1/29/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $104.40 $104.40 1/29/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 1/29/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $134.88 1/29/15 PAID BY' METHOD RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH Total Paid for REMODEL: $419.09 $419.09 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE SMI - COMMERCIAL 101-0000-20308 0 $5.60 $5.60 1/29/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY FIT GALS CLOSET CHECK R3534 1001 SKH Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $5.60 $5.60 TOTALS: Description: KOMAR DESERT CENTER - T.I. FIT GALS CLOSET Type: BUILDING, COMMERCIAL Subtype: REMODEL Status: APPROVED -CONDITIONS Applied: 1/13/2015 SKH Approved: 1/29/2015 BHA Parcel No: 600440006 Site Address: 79785 HIGHWAY 111 #102 LA QUINTA,CA 92253 Subdivision: PM 036269 Block: Lot: 6 Issued: Lot Sq Ft: 0 ' Building Sq Ft: 0 Zoning: Finaled: Valuation: $20,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: SUITE 102 - 3005 SF TENANT IMPROVEMENT -RETAIL STORE -FIT GALS CLOSET. "M" OCCUPANCY TYPE V -B CONSTRUCTION. 100 OCCUPANT LOAD. 2013 CODES **NO ELECTRICAL INSPECTION UNTIL LOAD CALCS ARE APPROVED** t Printed: Friday, January 30, 2015 11:34:11 AM 1 of 3 SYSTEMS I� ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME. ACTION DATE COMPLETION DATE NOTES EMAILED GREG WATERMAN RE: 1. Electrical load Calcs for the project. 2. Building Permit Fee of $474.03 (payable when the E-MAIL BURT HANADA 1/29/2015 contractor comes to the City to sign for the Building Permit. 3. Contractor bring a set of Plans for the County Assessor's office. PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 1/12/2015 1/13/2015 RECEIVED INFORMED GREG WATERMAN THAT ELECTRICAL LOAD CALCS REQUIRED & GENERAL CONTRACTOR WITH CITY BUSINESS ' TELEPHONE CALL BURT HANADA 1/28/2015 1/29/2015 LICENSE PRIOR TO PERMIT ISSUANCE. ALSO INFORMED GREG THAT PLANS ARE REDLINED WITH ACCESSIBILITY AND EGRESS ITEMS TO BE RESOLVED IN THE FIELD. CONDITIONS Printed: Friday, January 30, 2015 11:34:11 AM 1 of 3 SYSTEMS I� Printed: Friday, January 30, 2015 11:34:11 AM 2 of 3 CJ SYSTEMS CONTACTS CITY STATE ZIP PHONE FAX EMAIL NAME TYPE NAME ADDRESSI APPLICANT SOUTH WEST CONCEPTS -ARCHITECT 78115 CALLE ESTADO 201 LA QUINTA CA 92253 CONTRACTOR MATT KLEINE CONTRACTING 73950 22ND AVENUE SKY VALLEY CA 92241 RECEIPT # CHECK # METHOD OWNER P6K PORTFOLIO KDP 2301 ROSECRANS STE 2110 EL SEGUNDO CA 92253 TENANT FIT GALS CLOSET 79785 HIGHWAY 111, #102 LA QUINTA CA 92253 $1.00 1/29/15 R3534 Printed: Friday, January 30, 2015 11:34:11 AM 2 of 3 CJ SYSTEMS FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY .. - BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $1.00 - BSA: DEVICES, FIRST 20 101-0000-42403 0 $24.17 $24.17 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH Total Paid for ELECTRICAL: $48.34 $48.34 REMODEL,EA 101-0000-42400 0 $130.50 $130.50 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH ADDITIONAL 5000 SF REMODEL, EA 101-0000-42600 0 $104.40 $104.40 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH ADDITIONAL 500 SF PC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH REMODEL, FIRST 500 SF 101-0000-426000 $134.88 $134.88 1/29/15 R3534 1001 CHECK FIT GALS CLOSET SKH PC Total Paid for REMODEL: $419.09 $419.09 SMI -COMMERCIAL 101-0000-20308 1 0 $5.60 $5.60 1/29/15 1 R3534 1001 CHECK FIT GALS CLOSET SKH Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $5.60 $5.60 TOTALS: Printed: Friday, January 30, 2015 11:34:11 AM 2 of 3 CJ SYSTEMS Printed: Friday, January 30, 2015 11:34:11 AM 3 of 3 SYSTEMS RETURNED STATUS REMARKS REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES DATE GENERAL CONTRACTOR REQUIRED BURT APPROVED- NON-STRUCTURAL 1/12/2015 1/26/2015 1/28/2015 ELECTRICAL LOAD CALCS HANADA CONDITIONS PLAN REDLINED FOR CODE ITEMS. Printed: Friday, January 30, 2015 11:34:11 AM 3 of 3 SYSTEMS rpai4t -La da ' 'N ;TTrC Btttftlg ss Safety Alvistoil` � P.'O. . , Box 1504,78-495 Calk Tam fco NW 26 6' La.-Wita, CA 92253 -.-(760) 777--7012 B011CUng Application Permit and Tracking Sheet Pmjea. ddtaess:7 _ 85 M/ p146►F j 's Name:_ kh A. P. Nurhber. �j Od — 6" ^ Q y : . - t6itv--s Lege( De=ipdow T, Zap: ; Contractor. TADn/, V%4OW Ilk � Telephone: • 7 Address: PrnjtctDescription: City, ST, Zip: l�OM� 1 • Of St -9 Telephone: KKK WN �4,0 _ State Lk. # : City Lid. tkfit 15 Meir, BW, Daslgucri Addre=78#5 o -5K le -5 City' ST, zx Telephone: % b3W a Con*UCt%n Type:IrOocx�ancy: State Lia #: Pmjed We (circle one): Now Add'a Alter RrPaa Demo Name of Contact Person: Sq Ft•: I # Stories: # Unita: Telephone # of Contact Person:7W Estimakd Value'of Pmi&k Gne.,Q►InC �,`� .,i z� et%nlS TN ' r`AitiT• BIAT ufnmt nta sur ,r..... V Ran- # ASubmittal Plan Sets mega --Vee'd TR&OWG PT3RM[i; M. Plan Chmk submitted.1 Item , Amomnt Straduisl Chic:. Reviewed, ready for con-azons Plan c"Deposit_ _ Thus: Calts, WrA Contact Person Pian Check Balani Tl6e 24 C" Plans picked up Construction Plocd,pbtht plan Grading plan Plans resubmlthd.•. Methadicid 2" Review, ready for eorrett2a issue � jFj Electrics[ Subcontactor List called Contact Person Plumblag Grant Deed Plans #Ieked up SAU H.O.A. Approval Plans resubmitted Grading IN If0US81- Planting Approval. Reykw; may for oorrectionsllrsne F twilled Contact Person Pub. Wks. Aper ' Date of permit issue i School Fees JAIN 12 2015 CITY 0: LA QUINTA Tota! PsrmitBees 7 . p i pi Certificate of Compliance (Sign Lighting) (Pao t of SLTG-1C Project Harm" Phasc of Construction O ew Construction O Addition D Alteration P-- T- (�, Function Typc XOutdoor Signs O Iado* r Signs Pro*1 Address C Date Compliance Methal Used Wtaxlmum Allowed 7,? S 4DJ 4 /.11 j�—,(, l q Ughting Power O Altematt Ughting Sources Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and complete. Name � s LL ; a vh, <e c^-5-f.rJ Stgntttws Con'p"Y _ Date d �l Address I f applicable: j, .�« < Q � k l' '��c CEPIt O G. J� T V� �vt.1 CEPSS M City/StatcrLip L_, Phone: w-*, 2 Principal Lighting Designer's Decl ration Statement • 1 tem eligible under Division 3 of the California Business and Professions Code to accept responsibility for the lighting . design. • This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24. Pages 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance am consistent with the, information provided to document this design on the other applicable compliance forms, worksheets. calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name: Signature Company: Phonc Address: Uccnsc tY City/Statdzip: Date Sign Mandatory Measures Indicate location on building plans of Mandatory Sign Measures Note Block: Mandatory Sign Lighting Controls Ycs No 1 1133(x)1. All signs with permanently connected lighting are controlled with an automatic time switch control O that complies with theapplicable requirements of 119. §133(a)2. All outdoor signs are controlled with a photo control or outdoor astronomical time switch control. d ❑ 2 Exception to §133(a)2. Outdoor signs are in tunnels or large covered areas that require illumination during O daylight hours. §133(&)3. All outdoor signs arc controlled with a dimmer that provides the ability to automatically reduce O ,0 sign power by a minimum of 65 percent during nighttime hours. Exception I to §133(a)3. Signs are illuminated for less than one hour per day during daylight hours. 49: ❑ 3 Exception 2 to 1133(a)3. Outdoor signs are in tunnels or large covered areas that require illumination O during da li t hours. . Exception 3 to §133(&)3. Only metal.halide, high pressure sodium, cold cathode, or noon lamps are used to O 6 illuminated signs or parts of signs. 1133(a)4. An Electronic Message Center (EMC) having a new connected lighting power load greater than Y N IS kW has a control installed is capable of reducing the lighting power by a minimum of 30 percent when O t] N/A 4 receiving a demand response signal that is sent out by the local utility. _ Exception to §133(n)4. The EMC is required by a health or life safety statue, ordinance, or regulation, Y including but not limited to exit signs and traffic signs. O O 2008,Vonrexidenlial Compliance !-arms .dugas/ 2009 Certificate of Compliance and Field Ins ection Energy Checklist (Sign Li htin (Page 2 ot2 SLTGIC Project Name: Dau: Com fiance Method Maximum Allowed Lighting Power A g C D E F G H ( i K Design Complies? Light Field Allowed Watts Watts' YM Source I Ins ? v FM '� l p 9 E V, E C in Description or location and len location t� 7 '� _� A ¢ " V V " F v v v "" m � /21 13 C3 O ❑ ❑ ❑ ❑ ❑ O ❑ •❑ ❑ ❑ O Total Sign Area: 1. Design iVatts a total connected lighting load installed in the sigm including power used by lamps, ballasts, transformers, power supplies, etc. Ariare action to correct. Verily building arts if necessary. Use additional sheets if necessary. 2. /Fail then describe on Page ? of the lnupecdon Checklist Form and take appry The sins identified above; use only one or more of the following technologies: list all applicable numbers that apply in column 1 above I High un sodium lamp ncy 2 Puht start or ceramic metal halide tarmw served 0 a ballast with >_ 88% a reit 3 Pulse start metal halide l that are <_ 320 watts, are not 2J0 wait or 173 welt la and are served by a ballast with >_ 80Y efficiency t Neon or cold cathode larnos with trans ormer or er s y e tcielu r >_ 7 % with rated our w current S0 rnA 5 Neon or cold cathode 1 with ownformer or power s v efficiency > 68% wilt rated out t currant > SO -A 6 Fluorescent janW with a minimum color rendering index (CRO o 80 7 Light e'"iffing diodes O with a Power s with > 80% a ncien having a nantplate output power less an equal to 250 wotu, and Singk voltage LED externa/ power supplies designed to convert 120 volt AC Ltpvt into lower vwltbge DC or AC output• htha 8 ceni ed to the Energy Conu4ssian as coAWIjiqg with t/te SE&Icabte rc uirureents o/the Appliance Efficlemm, Regulations itle IO 9 Comact fluorescent 1 that do not contain a medium screw base sockets (E21/E26 10 Elecuonk ballasts with a undamenta/ out t K >_ 20 kth Field Inspector Notes or Discrepancies 2008 tVontresideniial Compliance Fortes August 2009